Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Perfusion ; 38(2): 418-421, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-34962840

RESUMO

Tyrosine kinase inhibitors (TKI) are known to be highly effective in the treatment of various cancers with kinase-domain mutations such as chronic myelogenous leukemia. However, they have important side effects such as increased vascular permeability and pulmonary hypertension. In patients undergoing pulmonary endarterectomy with deep hypothermic circulatory arrest, these side effects may exacerbate postoperative complications such as reperfusion edema and persistent pulmonary hypertension. We report on a simple modification of the perfusion strategy to increase intravascular oncotic pressure by retrograde autologous priming and the addition of packed cells and albumin in a patient treated with a TKI.


Assuntos
Neoplasias Hematológicas , Hipertensão Pulmonar , Embolia Pulmonar , Humanos , Hipertensão Pulmonar/tratamento farmacológico , Hipertensão Pulmonar/cirurgia , Perfusão/efeitos adversos , Endarterectomia/métodos , Neoplasias Hematológicas/complicações , Embolia Pulmonar/complicações
2.
Perfusion ; 36(1): 87-96, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32522088

RESUMO

INTRODUCTION: Pulmonary endarterectomy requires cardiopulmonary bypass and deep hypothermic circulatory arrest, which may prolong the activated clotting time. We investigated whether activated clotting time-guided anticoagulation under these circumstances suppresses hemostatic activation. METHODS: Individual heparin sensitivity was determined by the heparin dose-response test, and anticoagulation was monitored by the activated clotting time and heparin concentration. Perioperative hemostasis was evaluated by thromboelastometry, platelet aggregation, and several plasma coagulation markers. RESULTS: Eighteen patients were included in this study. During cooling, tube-based activated clotting time increased from 719 (95% confidence interval = 566-872 seconds) to 1,273 (95% confidence interval = 1,136-1,410 seconds; p < 0.01) and the cartridge-based activated clotting time increased from 693 (95% confidence interval = 590-796 seconds) to 883 (95% confidence interval = 806-960 seconds; p < 0.01), while thrombin-antithrombin showed an eightfold increase. The heparin concentration showed a slightly declining trend during cardiopulmonary bypass. After protamine administration (protamine-to-heparin bolus ratio of 0.82 (0.71-0.90)), more than half of the patients showed an intrinsically activated coagulation test and intrinsically activated coagulation test without heparin effect clotting time >240 seconds. Platelet aggregation through activation of the P2Y12 (adenosine diphosphate test) and thrombin receptor (thrombin receptor activating peptide-6 test) decreased (both -33%) and PF4 levels almost doubled (from 48 (95% confidence interval = 42-53 ng/mL) to 77 (95% confidence interval = 71-82 ng/mL); p < 0.01) between weaning from cardiopulmonary bypass and 3 minutes after protamine administration. CONCLUSION: This study shows a wide variation in individual heparin sensitivity in patients undergoing pulmonary endarterectomy with deep hypothermic circulatory arrest. Although activated clotting time-guided anticoagulation management may underestimate the level of anticoagulation and consequently result in a less profound inhibition of hemostatic activation, this study lacked power to detect adverse outcomes.


Assuntos
Ponte Cardiopulmonar , Parada Circulatória Induzida por Hipotermia Profunda , Anticoagulantes/farmacologia , Anticoagulantes/uso terapêutico , Coagulação Sanguínea , Ponte Cardiopulmonar/efeitos adversos , Parada Circulatória Induzida por Hipotermia Profunda/efeitos adversos , Endarterectomia , Heparina/farmacologia , Heparina/uso terapêutico , Humanos
3.
Crit Care ; 20: 55, 2016 Mar 10.
Artigo em Inglês | MEDLINE | ID: mdl-26968380

RESUMO

BACKGROUND: The safety of perioperative hyperoxia is currently unclear. Previous studies in patients undergoing coronary artery bypass surgery suggest reduced myocardial damage when avoiding extreme perioperative hyperoxia (>400 mmHg). In this study we investigated whether an oxygenation strategy from moderate hyperoxia to a near-physiological oxygen tension reduces myocardial damage and improves haemodynamics, organ dysfunction and oxidative stress. METHODS: This was a single-blind, single-centre, open-label, randomised controlled trial in patients undergoing elective coronary artery bypass surgery. Fifty patients were randomised to a partial pressure of oxygen in arterial blood (PaO2) target of 200-220 mmHg during cardiopulmonary bypass and 130-150 mmHg during intensive care unit (ICU) admission (control group) versus lower targets of 130-150 mmHg during cardiopulmonary bypass and 80-100 mmHg at the ICU (conservative group). Primary outcome was myocardial injury (CK-MB and Troponin-T) at ICU admission and 2, 6 and 12 hours thereafter. RESULTS: Weighted PaO2 during cardiopulmonary bypass was 220 mmHg (interquartile range (IQR) 211-233) vs. 157 (151-162) in the control and conservative group, respectively (P < 0.0001). During ICU admission, weighted PaO2 was 107 mmHg (86-141) vs. 90 (84-98) (P = 0.03), respectively. Area under the curve of CK-MB was median 23.5 µg/L/h (IQR 18.4-28.1) vs. 21.5 (15.8-26.6) (P = 0.35) and 0.30 µg/L/h (0.25-0.44) vs. 0.39 (0.24-0.43) (P = 0.81) for Troponin-T. Cardiac index, systemic vascular resistance index, creatinine, lactate and F2-isoprostane levels were not different between groups. CONCLUSIONS: Compared to moderate hyperoxia, a near-physiological oxygen strategy does not reduce myocardial damage in patients undergoing coronary artery bypass surgery. Conservative oxygen administration was not associated with increased lactate levels or hypoxic events. TRIAL REGISTRATION: Netherlands Trial Registry NTR4375, registered on 30 January 2014.


Assuntos
Ponte de Artéria Coronária/efeitos adversos , Ponte de Artéria Coronária/mortalidade , Hiperóxia/metabolismo , Hiperóxia/cirurgia , Idoso , Anestesia , Gasometria , Feminino , Humanos , Hiperóxia/patologia , Complicações Intraoperatórias/prevenção & controle , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica/métodos , Países Baixos , Complicações Pós-Operatórias/prevenção & controle , Método Simples-Cego
4.
ERJ Open Res ; 7(4)2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34616835

RESUMO

For young adults with end-stage idiopathic pulmonary hypertension, a valved graft connecting the central pulmonary artery to the distal aortic arch can provide substantial palliation of symptoms and may defer lung transplantation https://bit.ly/2TvMFFC.

5.
Thromb Res ; 133(6): 1141-4, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24703296

RESUMO

BACKGROUND: Hemostasis monitoring in cardiac surgery could benefit from an easy to use and fast point-of-care coagulation monitor, since routine laboratory tests have a delay of 30-45minutes. This study investigated the level of agreement between the point-of-care prothrombin time (PT) with central laboratory PT before and after cardiopulmonary bypass. METHODS: Bland Altman and error grid analysis were used to analyze the agreement between the point-of-care Coaguchek XS Pro device (POC-PT) and the central laboratory prothrombin time (LAB-PT) before cardiopulmonary bypass (CPB) and 3minutes after protamine administration. Prothrombin times were expressed in international normalized ratios (INR). RESULTS: The average POC-PT and LAB-PT values of 73 patients were 1.06±0.14 and 1.09±0.13 (P=0.10) before CPB. POC-PT measurements before CPB showed a good agreement with the LAB-PT, with a bias of -0.02±0.07 INR and 94% of the values being represented in the clinical acceptable zone of error grid analysis. The mean POC-PT 3minutes after protamine administration was significantly lower than the LAB-PT (1.35±0.12 vs. 1.70±0.18; P<0.001). The PT at 3minutes after protamine administration showed a bias of 0.36±0.14, and 82% of the values were located outside of the clinical acceptable zone in the error grid analysis. CONCLUSIONS: Point-of-care prothrombin time testing was in concordance with conventional laboratory PT prior to cardiopulmonary bypass. At 3minutes following protamine administration, PT values of the point-of-care device were structurally lower than the laboratory PT values, leading to a disagreement between both tests at that time point.


Assuntos
Procedimentos Cirúrgicos Cardíacos/métodos , Ponte Cardiopulmonar/métodos , Sistemas Automatizados de Assistência Junto ao Leito , Tempo de Protrombina/métodos , Idoso , Feminino , Humanos , Laboratórios , Masculino , Tempo de Protrombina/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA