Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 57
Filtrar
1.
Sensors (Basel) ; 19(18)2019 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-31500195

RESUMO

A body pressure relief system was newly developed with optical pressure sensors for pressure ulcer prevention. Unlike a conventional alternating pressure air mattress (APAM), this system automatically regulates air flow into a body supporting mattress with adaptive inflation (or deflation) duration in response to the pressure level in order to reduce skin stress due to prolonged high pressures. The system continuously quantifies the body pressure distribution using time-of-flight (ToF) optical sensors. The proposed pressure sensor, a ToF optical sensor in the air-filled cell, measures changes in surface height of mattress when pressed under body weight, thereby indirectly indicating the interface pressure. Non-contact measurement of optical sensor usually improves the durability and repeatability of the system. The pressure sensor was successfully identified the 4 different-predefined postures, and quantitatively measured the body pressure distribution of them. Duty cycle of switches in solenoid valves was adjusted to 0-50% for pressure relief, which shows that the interface pressure was lower than 32 mmHg for pressure ulcer prevention.

2.
Sensors (Basel) ; 17(8)2017 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-28767051

RESUMO

This paper presents a thermal convection-based sensor fabricated using simple microelectromechanical systems (MEMS)-based processes. This sensor can be applied to both acceleration and inclination measurements without modifying the structure. Because the operating mechanism of the accelerometer is the thermal convection of a gas medium, a simple model is proposed and developed in which the performance of the thermal convection-based accelerometer is closely associated with the Grashof number, Gr and the Prandtl number, Pr. This paper discusses the experiments that were performed by varying several parameters such as the heating power, cavity size, gas media, and air pressure. The experimental results demonstrate that an increase in the heating power, pressure, and cavity size leads to an increase in the accelerometer sensitivity. However, an increase in the pressure and/or cavity size results in a decrease in the frequency bandwidth. This paper also discusses the fact that a working-gas medium with a large thermal diffusivity and small kinematic viscosity can widen the frequency bandwidth and increase the sensitivity, respectively.

3.
Sensors (Basel) ; 17(4)2017 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-28406469

RESUMO

In this study, we developed a pore size/pore area-controlled optical biosensor-based anodic aluminum oxide (AAO) nanostructure. As the pore size of AAO increases, the unit cell of AAO increases, which also increases the non-pore area to which the antibody binds. The increase in the number of antibodies immobilized on the surface of the AAO enables effective detection of trace amounts of antigen, because increased antigen-antibody bonding results in a larger surface refractive index change. High sensitivity was thus achieved through amplification of the interference wave of two vertically-incident reflected waves through the localized surface plasmon resonance phenomenon. The sensitivity of the fabricated sensor was evaluated by measuring the change in wavelength with the change in the refractive index of the device surface, and sensitivity was increased with increasing pore-size and non-pore area. The sensitivity of the fabricated sensor was improved and up to 11.8 ag/mL serum amyloid A1 antigen was detected. In addition, the selectivity of the fabricated sensor was confirmed through a reaction with a heterogeneous substance, C-reactive protein antigen. By using hard anodization during fabrication of the AAO, the fabrication time of the device was reduced and the AAO chip was fabricated quickly and easily.


Assuntos
Nanoestruturas , Óxido de Alumínio , Proteína C-Reativa , Eletrodos , Ressonância de Plasmônio de Superfície
4.
Sensors (Basel) ; 16(7)2016 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-27409620

RESUMO

In this paper, we propose a temperature/thermal sensor that contains a Rhodamine-B sensing membrane. We applied two different sensing methods, namely, fiber-optic pulse width modulation (PWM) and an interdigitated capacitor (IDC)-based temperature sensor to measure the temperature from 5 °C to 100 °C. To the best of our knowledge, the fiber-optic PWM-based temperature sensor is reported for the first time in this study. The proposed fiber-optic PWM temperature sensor has good sensing ability; its sensitivity is ~3.733 mV/°C. The designed temperature-sensing system offers stable sensing responses over a wide dynamic range, good reproducibility properties with a relative standard deviation (RSD) of ~0.021, and the capacity for a linear sensing response with a correlation coefficient of R² ≈ 0.992 over a wide sensing range. In our study, we also developed an IDC temperature sensor that is based on the capacitance variation principle as the IDC sensing element is heated. We compared the performance of the proposed temperature-sensing systems with different fiber-optic temperature sensors (which are based on the fiber-optic wavelength shift method, the long grating fiber-optic Sagnac loop, and probe type fiber-optics) in terms of sensitivity, dynamic range, and linearity. We observed that the proposed sensing systems have better sensing performance than the above-mentioned sensing system.

5.
Sensors (Basel) ; 16(2): 265, 2016 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-26907291

RESUMO

In this paper, we proposed an interdigitated capacitor (IDC)-based glucose biosensor to measure different concentrations of glucose from 1 µM to 1 M. We studied four different types of solvatochromic dyes: Auramine O, Nile red, Rhodamine B, and Reichardt's dye (R-dye). These dyes were individually incorporated into a polymer [polyvinyl chloride (PVC)] and N,N-Dimethylacetamide (DMAC) solution to make the respective dielectric/sensing materials. To the best of our knowledge, we report for the first time an IDC glucose biosensing system utilizing a solvatochromic-dye-containing sensing membrane. These four dielectric or sensing materials were individually placed into the interdigitated electrode (IDE) by spin coating to make four IDC glucose biosensing elements. The proposed IDC glucose biosensor has a high sensing ability over a wide dynamic range and its sensitivity was about 23.32 mV/decade. It also has fast response and recovery times of approximately 7 s and 5 s, respectively, excellent reproducibility with a standard deviation of approximately 0.023, highly stable sensing performance, and real-time monitoring capabilities. The proposed IDC glucose biosensor was compared with an IDC, potentiometric, FET, and fiber-optic glucose sensor with respect to response time, dynamic range width, sensitivity, and linearity. We observed that the designed IDC glucose biosensor offered excellent performance.


Assuntos
Técnicas Biossensoriais/métodos , Glucose/análise , Corantes/química , Eletrodos
6.
Sensors (Basel) ; 16(5)2016 05 10.
Artigo em Inglês | MEDLINE | ID: mdl-27171095

RESUMO

In this paper, an electronic tongue/taste sensor array containing different interdigitated capacitor (IDC) sensing elements to detect different types of tastes, such as sweetness (glucose), saltiness (NaCl), sourness (HCl), bitterness (quinine-HCl), and umami (monosodium glutamate) is proposed. We present for the first time an IDC electronic tongue using sensing membranes containing solvatochromic dyes. The proposed highly sensitive (30.64 mV/decade sensitivity) IDC electronic tongue has fast response and recovery times of about 6 s and 5 s, respectively, with extremely stable responses, and is capable of linear sensing performance (R² ≈ 0.985 correlation coefficient) over the wide dynamic range of 1 µM to 1 M. The designed IDC electronic tongue offers excellent reproducibility, with a relative standard deviation (RSD) of about 0.029. The proposed device was found to have better sensing performance than potentiometric-, cascoded compatible lateral bipolar transistor (C-CLBT)-, Electronic Tongue (SA402)-, and fiber-optic-based taste sensing systems in what concerns dynamic range width, response time, sensitivity, and linearity. Finally, we applied principal component analysis (PCA) to distinguish between various kinds of taste in mixed taste compounds.


Assuntos
Nariz Eletrônico , Paladar , Corantes , Glucose , Reprodutibilidade dos Testes , Língua
7.
Sensors (Basel) ; 16(11)2016 Nov 09.
Artigo em Inglês | MEDLINE | ID: mdl-27834865

RESUMO

In this study, we propose a highly sensitive multichannel pH sensor that is based on an optical-fiber pulse width modulation (PWM) technique. According to the optical-fiber PWM method, the received sensing signal's pulse width changes when the optical-fiber pH sensing-element of the array comes into contact with pH buffer solutions. The proposed optical-fiber PWM pH-sensing system offers a linear sensing response over a wide range of pH values from 2 to 12, with a high pH-sensing ability. The sensitivity of the proposed pH sensor is 0.46 µs/pH, and the correlation coefficient R² is approximately 0.997. Additional advantages of the proposed optical-fiber PWM pH sensor include a short/fast response-time of about 8 s, good reproducibility properties with a relative standard deviation (RSD) of about 0.019, easy fabrication, low cost, small size, reusability of the optical-fiber sensing-element, and the capability of remote sensing. Finally, the performance of the proposed PWM pH sensor was compared with that of potentiometric, optical-fiber modal interferometer, and optical-fiber Fabry-Perot interferometer pH sensors with respect to dynamic range width, linearity as well as response and recovery times. We observed that the proposed sensing systems have better sensing abilities than the above-mentioned pH sensors.

8.
Sensors (Basel) ; 16(1)2016 Jan 07.
Artigo em Inglês | MEDLINE | ID: mdl-26751453

RESUMO

We propose a solution-processable ultraviolet (UV) photodetector with a pn-heterojunction hybrid photoactive layer (HPL) that is composed of poly-n-vinylcarbazole (PVK) as a p-type polymer and ZnO nanoparticles (NPs) as an n-type metal oxide. To observe the effective photo-inducing ability of the UV photodetector, we analyzed the optical and electrical properties of HPL which is controlled by the doping concentration of n-type ZnO NPs in PVK matrix. Additionally, we confirmed that the optical properties of HPL dominantly depend on the ZnO NPs from the UV-vis absorption and the photoluminescence (PL) spectral measurements. This HPL can induce efficient charge transfer in the localized narrow pn-heterojunction domain and increases the photocurrent gain. It is essential that proper doping concentration of n-type ZnO NPs in polymer matrix is obtained to improve the performance of the UV photodetector. When the ZnO NPs are doped with the optimized concentration of 3.4 wt.%, the electrical properties of the photocurrent are significantly increased. The ratio of the photocurrent was approximately 10³ higher than that of the dark current.


Assuntos
Nanopartículas Metálicas/química , Nanocompostos/química , Polivinil/química , Óxido de Zinco/química , Processos Fotoquímicos , Espectrofotometria Ultravioleta
9.
Sensors (Basel) ; 15(6): 13201-21, 2015 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-26057036

RESUMO

In this study, we designed and developed an interdigitated capacitor (IDC)-based taste sensor array to detect different taste substances. The designed taste sensing array has four IDC sensing elements. The four IDC taste sensing elements of the array are fabricated by incorporating four different types of lipids into the polymer, dioctyl phenylphosphonate (DOPP) and tetrahydrofuran (THF) to make the respective dielectric materials that are individually placed onto an interdigitated electrode (IDE) via spin coating. When the dielectric material of an IDC sensing element comes into contact with a taste substance, its dielectric properties change with the capacitance of the IDC sensing element; this, in turn, changes the voltage across the IDC, as well as the output voltage of each channel of the system. In order to assess the effectiveness of the sensing system, four taste substances, namely sourness (HCl), saltiness (NaCl), sweetness (glucose) and bitterness (quinine-HCl), were tested. The IDC taste sensor array had rapid response and recovery times of about 12.9 s and 13.39 s, respectively, with highly stable response properties. The response property of the proposed IDC taste sensor array was linear, and its correlation coefficient R2 was about 0.9958 over the dynamic range of the taste sensor array as the taste substance concentration was varied from 1 µM to 1 M. The proposed IDC taste sensor array has several other advantages, such as real-time monitoring capabilities, high sensitivity 45.78 mV/decade, good reproducibility with a standard deviation of about 0.029 and compactness, and the circuitry is based on readily available and inexpensive electronic components. The proposed IDC taste sensor array was compared with the potentiometric taste sensor with respect to sensitivity, dynamic range width, linearity and response time. We found that the proposed IDC sensor array has better performance. Finally, principal component analysis (PCA) was applied to discriminate different types of taste of the mixed taste substances.

10.
Sensors (Basel) ; 15(8): 18416-26, 2015 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-26225981

RESUMO

In this paper, we propose an AlGaN/GaN high electron mobility transistor (HEMT)-based biosensor for the detection of C-reactive protein (CRP) using a null-balancing circuit. A null-balancing circuit was used to measure the output voltage of the sensor directly. The output voltage of the proposed biosensor was varied by antigen-antibody interactions on the gate surface due to CRP charges. The AlGaN/GaN HFET-based biosensor with null-balancing circuit applied shows that CRP can be detected in a wide range of concentrations, varying from 10 ng/mL to 1000 ng/mL. X-ray photoelectron spectroscopy was carried out to verify the immobilization of self-assembled monolayer with Au on the gated region.


Assuntos
Compostos de Alumínio/química , Técnicas Biossensoriais/instrumentação , Proteína C-Reativa/análise , Elétrons , Gálio/química , Transistores Eletrônicos , Eletricidade , Humanos , Espectroscopia Fotoeletrônica
11.
J Nanosci Nanotechnol ; 14(4): 3256-61, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24734764

RESUMO

Herein, we report an attractive, simple and templateless synthetic method for the formation of anisotropic gold nanostructures. Gold 'mesoflowers' consisting of arrays of nanoplatelets were synthesized by electrochemical gold deposition on/off conditions onto a conducting poly(diphenylamine) (PDPA) support matrix. A possible forming mechanism of anisotropic gold nanostructures is presented. The electronic and electrochemical properties of gold nanoflower decorated PDPA in an assembled diode configuration were evaluated.

12.
J Nanosci Nanotechnol ; 14(8): 5937-41, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25936031

RESUMO

To improve the operation lifetime of organic solar cell, two different diphenylacetylene polymers were tested as UV blocking layer. One of them showed either stronger UV absorption or a relatively intense fluorescence emission in the visible region which is well overlapped with the absorption of P3HT in the OSC. The diphenylacetylene polymer film significantly improved the operation lifetime of the OSC by efficiently absorbing the UV light, while reducing the UV-light energy loss to a minimum by converting the UV light to visible light through a down-conversion process.


Assuntos
Acetileno/análogos & derivados , Polímeros/química , Energia Solar , Acetileno/química , Raios Ultravioleta
13.
Sensors (Basel) ; 14(12): 23321-36, 2014 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-25490592

RESUMO

In this paper, we propose a volatile organic compound (VOC) gas sensing system with high sensitivity and a wide dynamic range that is based on the principle of the heterodyne frequency modulation method. According to this method, the time period of the sensing signal shift when Nile Red containing a VOC-sensitive membrane of a fiber-optic sensing element comes into contact with a VOC. This sensing membrane produces strong, fast and reversible signals when exposed to VOC gases. The response and recovery times of the proposed sensing system were less than 35 s, and good reproducibility and accuracy were obtained.


Assuntos
Tecnologia de Fibra Óptica/instrumentação , Gases/análise , Microquímica/instrumentação , Refratometria/instrumentação , Compostos Orgânicos Voláteis/análise , Desenho de Equipamento , Análise de Falha de Equipamento , Gases/química , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Compostos Orgânicos Voláteis/química
14.
Sensors (Basel) ; 14(7): 11659-71, 2014 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-24988381

RESUMO

We have developed a multi-array side-polished optical-fiber gas sensor for the detection of volatile organic compound (VOC) gases. The side-polished optical-fiber coupled with a polymer planar waveguide (PWG) provides high sensitivity to alterations in refractive index. The PWG was fabricated by coating a solvatochromic dye with poly(vinylpyrrolidone). To confirm the effectiveness of the sensor, five different sensing membranes were fabricated by coating the side-polished optical-fiber using the solvatochromic dyes Reinhardt's dye, Nile red, 4-aminophthalimide, 4-amino-N-methylphthalimide, and 4-(dimethylamino)cinnamaldehyde, which have different polarities that cause changes in the effective refractive index of the sensing membrane owing to evanescent field coupling. The fabricated gas detection system was tested with five types of VOC gases, namely acetic acid, benzene, dimethylamine, ethanol, and toluene at concentrations of 1, 2,…,10 ppb. Second-regression and principal component analyses showed that the response properties of the proposed VOC gas sensor were linearly shifted bathochromically, and each gas showed different response characteristics.


Assuntos
Corantes/química , Tecnologia de Fibra Óptica/instrumentação , Análise em Microsséries/instrumentação , Ressonância de Plasmônio de Superfície/instrumentação , Transdutores , Compostos Orgânicos Voláteis/análise , Desenho de Equipamento , Análise de Falha de Equipamento , Compostos Orgânicos Voláteis/química
15.
Opt Express ; 21(17): 20119-30, 2013 Aug 26.
Artigo em Inglês | MEDLINE | ID: mdl-24105558

RESUMO

In this paper, we proposed a new type high sensitive volatile organic compounds (VOCs) gas sensor array that is based on the pulse width modulation technique. Four different types of solvatochromic dyes and two different types of polymers, were used to make the five different types of sensing membranes. These were deposited on the five side-polished optical fibers by a spin coater to make the five different sensing elements of the array. In order to ascertain the effectiveness of the sensors, five VOC gases were tested. Finally, principal component analysis (PCA) has been used to discriminates different types of VOCs.


Assuntos
Tecnologia de Fibra Óptica/instrumentação , Fibras Ópticas , Compostos Orgânicos Voláteis/análise , Corantes/química , Gases/análise , Conformação Molecular , Análise de Componente Principal , Processamento de Sinais Assistido por Computador
16.
Eur J Radiol ; 165: 110887, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37245342

RESUMO

Prostate MRI plays an important role in imaging the prostate gland and surrounding tissues, particularly in the diagnosis and management of prostate cancer. With the widespread adoption of multiparametric magnetic resonance imaging in recent years, the concerns surrounding the variability of imaging quality have garnered increased attention. Several factors contribute to the inconsistency of image quality, such as acquisition parameters, scanner differences and interobserver variabilities. While efforts have been made to standardize image acquisition and interpretation via the development of systems, such as PI-RADS and PI-QUAL, the scoring systems still depend on the subjective experience and acumen of humans. Artificial intelligence (AI) has been increasingly used in many applications, including medical imaging, due to its ability to automate tasks and lower human error rates. These advantages have the potential to standardize the tasks of image interpretation and quality control of prostate MRI. Despite its potential, thorough validation is required before the implementation of AI in clinical practice. In this article, we explore the opportunities and challenges of AI, with a focus on the interpretation and quality of prostate MRI.


Assuntos
Imageamento por Ressonância Magnética Multiparamétrica , Neoplasias da Próstata , Masculino , Humanos , Imageamento por Ressonância Magnética/métodos , Próstata/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Inteligência Artificial , Imageamento por Ressonância Magnética Multiparamétrica/métodos , Estudos Retrospectivos
17.
Opt Express ; 19(18): 17427-38, 2011 Aug 29.
Artigo em Inglês | MEDLINE | ID: mdl-21935109

RESUMO

We demonstrate a vertical-field-driven polymer-stabilized blue phase liquid crystal (PS-BPLC) mode for solving low transmittance and high driving voltage problems in conventional in-plane-switching (IPS) PS-BPLC modes. By controlling the ray directions of incident beams by means of two prism sheets attached to the top and bottom substrates, continuous grayscale properties can be achieved with a vertical field, where the transmittance of the proposed structure can be increased to become twice as high as that of a IPS PS-BPLC cell, and its driving voltage can also be lowered by about 20 V. With the vertical-field-driven PS-BPLC mode, the hysteresis problem of the IPS PS-BPLC mode can also be solved due to a reduction of the electric field required to achieve sufficient field-induced retardation.

18.
Opt Express ; 19(23): 22882-91, 2011 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-22109166

RESUMO

We propose a design for a highly sensitive biosensor based on nanostructured anodized aluminum oxide (AAO) substrates. A gold-deposited AAO substrate exhibits both optical interference and localized surface plasmon resonance (LSPR). In our sensor, application of these disparate optical properties overcomes problems of limited sensitivity, selectivity, and dynamic range seen in similar biosensors. We fabricated uniform periodic nanopore lattice AAO templates by two-step anodizing and assessed their suitability for application in biosensors by characterizing the change in optical response on addition of biomolecules to the AAO template. To determine the suitability of such structures for biosensing applications, we immobilized a layer of C-reactive protein (CRP) antibody on a gold coating atop an AAO template. We then applied a CRP antigen (Ag) atop the immobilized antibody (Ab) layer. The shift in reflectance is interpreted as being caused by the change in refractive index with membrane thickness. Our results confirm that our proposed AAO-based biosensor is highly selective toward detection of CRP antigen, and can measure a change in CRP antigen concentration of 1 fg/ml. This method can provide a simple, fast, and sensitive analysis for protein detection in real-time.


Assuntos
Nanoestruturas/química , Ressonância de Plasmônio de Superfície/métodos , Óxido de Alumínio/química , Anticorpos Imobilizados , Antígenos/análise , Antígenos/imunologia , Proteína C-Reativa/análise , Proteína C-Reativa/imunologia , Eletrodos , Ouro/química , Humanos , Membranas Artificiais , Microscopia de Força Atômica , Nanoestruturas/ultraestrutura , Porosidade
19.
Bioorg Med Chem Lett ; 21(20): 6148-53, 2011 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-21890357

RESUMO

One of the obvious disadvantages of natural peptides is their liability to proteases. Among the several solutions for this issue, peptoids or oligomers of N-substituted glycine have emerged as a promising tool that may enhance the stability of proteolysis-susceptible natural peptides. We have synthesized the drosocin and its glyco-peptoid analogues linked O-GalNAc at the Thr(11) residue. One of our glyco-peptoid analogues showed an increased antibacterial activity by the modification of the Thr(11) residue with glyco-peptoid. Structure-activity relationship studies revealed that the antibacterial activity by glyco-peptoid drosocin requires three key elements: free hydroxyl group on the carbohydrate moiety, γ-methyl group of the Thr(11) residue derivative and (S)-configuration over (R)-configuration.


Assuntos
Antibacterianos/química , Antibacterianos/farmacologia , Drosophila melanogaster/química , Glicopeptídeos/química , Glicopeptídeos/farmacologia , Peptoides/química , Peptoides/farmacologia , Animais , Peptídeos Catiônicos Antimicrobianos/química , Peptídeos Catiônicos Antimicrobianos/farmacologia , Escherichia coli/efeitos dos fármacos , Infecções por Escherichia coli/tratamento farmacológico , Proteínas de Insetos/química , Proteínas de Insetos/farmacologia , Relação Estrutura-Atividade
20.
J Nanosci Nanotechnol ; 11(1): 432-6, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21446470

RESUMO

Reported herein are the effects of the fabrication variables and surface capping of nanocrystal quantum dots (NQDs) on the characteristics of NQDs-based light-emitting diodes (LEDs). The molecular weight of the hole transport layer (HTL) material and the annealing conditions of the NQDs layer were chosen as fabrication process variables. Their effects on the layer characteristics and device efficiency were characterized. The maximum brightness varied over 50% according to the molecular weight of the HTL material. The optimized annealing temperature was shown to improve the maximum brightness by 20%. The surface-capping molecules of the NQDs were changed from conventional trioctyl phosphine/trioctyl phosphine oxide (TOPO/TOP) to pyridine and were incorporated into LEDs, and its effects on the device characteristics were discussed.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA