Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Mikrochim Acta ; 191(3): 148, 2024 02 20.
Artigo em Inglês | MEDLINE | ID: mdl-38374311

RESUMO

A unique combination of a specific nucleic acid restriction endonuclease (REase) and atom transfer radical polymerization (ATRP) signal amplification strategy was employed for the detection of T790M mutations prevalent in the adjuvant diagnosis of lung cancer. REase selectively recognizes and cleaves T790M mutation sites on double-stranded DNA formed by hybridization of a capture sequence and a target sequence. At the same time, the ATRP strategy resulted in the massive aggregation of upconverted nanoparticles (UCNPs), which significantly improved the sensitivity of the biosensor. In addition, the UCNPs have excellent optical properties and can eliminate the interference of autofluorescence in the samples, thus further improving the detection sensitivity. The proposed upconversion fluorescent biosensor is characterized by high specificity, high sensitivity, mild reaction conditions, fast response time, and a detection limit as low as 0.14 fM. The performance of the proposed biosensor is comparable to that of clinical PCR methods when applied to clinical samples. This work presents a new perspective for assisted diagnosis in the pre-intervention stage of tumor diagnostics in the early stage of precision oncology treatments.


Assuntos
Técnicas Biossensoriais , Neoplasias Pulmonares , Humanos , Neoplasias Pulmonares/genética , Enzimas de Restrição do DNA , Receptores ErbB/genética , Polimerização , Clivagem do DNA , Limite de Detecção , Mutação , Medicina de Precisão , Inibidores de Proteínas Quinases , Técnicas Biossensoriais/métodos
2.
Food Chem ; 463(Pt 4): 141494, 2024 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-39366095

RESUMO

An innovative method for carbendazim (CBZ) detection was developed, consisting of an electrochemical-fluorescence dual-mode biosensor based on magneto-fluorescent composite M-CDs. M-CDs, as the fluorescent probe of this sensor, could combine the electrical signal-ferrocene to achieve the "signal switching" by specifically recognizing CBZ through aptamers, of which magnetic property was used to quickly separate from complex substrates without interference. The dual-mode sensor based on M-CDs demonstrated excellent linear responses in both electrochemical and fluorescence assays. It achieved detection ranges of 10 fg/mL - 300 ng/mL and 60 fg/mL - 100 ng/mL with detection limits (LODs) of 1.4 fg/mL and 2.3 fg/mL. The sensor exhibited exceptional detection performance, stability and anti-interference. In addition, the results of the sensor in actual samples were consistent with those of enzyme-linked immunosorbent assay (ELISA), which further demonstrated that the sensor could accurately trace detecting CBZ in real samples and had a certain application prospect.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA