Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Med Phys ; 36(2): 329-38, 2009 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19291972

RESUMO

In adaptive radiation therapy the treatment planning kilovoltage CT (kVCT) images need to be registered with daily CT images. Daily megavoltage CT (MVCT) images are generally noisier than the kVCT images. In addition, in the abdomen, low image contrast, differences in bladder filling, differences in bowel, and rectum filling degrade image usefulness and make deformable image registration very difficult. The authors have developed a procedure to overcome these difficulties for better deformable registration between the abdominal kVCT and MVCT images. The procedure includes multiple image preprocessing steps and a two deformable registration steps. The image preprocessing steps include MVCT noise reduction, bowel gas pockets detection and painting, contrast enhancement, and intensity manipulation for critical organs. The first registration step is carried out in the local region of the critical organs (bladder, prostate, and rectum). It requires structure contours of these critical organs on both kVCT and MVCT to obtain good registration accuracy on these critical organs. The second registration step uses the first step results and registers the entire image with less intensive computational requirement. The two-step approach improves the overall computation speed and works together with these image preprocessing steps to achieve better registration accuracy than a regular single step registration. The authors evaluated the procedure on multiple image datasets from prostate cancer patients and gynecological cancer patients. Compared to rigid alignment, the proposed method improves volume matching by over 60% for the critical organs and reduces the prostate landmark registration errors by 50%.


Assuntos
Abdome , Processamento de Imagem Assistida por Computador/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia/métodos , Abdome/efeitos da radiação , Bases de Dados Factuais , Feminino , Neoplasias dos Genitais Femininos/diagnóstico por imagem , Neoplasias dos Genitais Femininos/radioterapia , Humanos , Masculino , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Radiografia Abdominal , Tomografia Computadorizada por Raios X
2.
Med Phys ; 35(10): 4735-43, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18975718

RESUMO

PURPOSE: To develop and validate methods for small-animal CNS radiotherapy using the microRT system. MATERIALS AND METHODS: A custom head immobilizer was designed and built to integrate with a pre-existing microRT animal couch. The Delrin couch-immobilizer assembly, compatible with multiple imaging modalities (CT, microCT, microMR, microPET, microSPECT, optical), was first imaged via CT in order to verify the safety and reproducibility of the immobilization method. Once verified, the subject animals were CT-scanned while positioned within the couch-immobilizer assembly for treatment planning purposes. The resultant images were then imported into CERR, an in-house-developed research treatment planning system, and registered to the microRTP treatment planning space using rigid registration. The targeted brain was then contoured and conformal radiotherapy plans were constructed for two separate studies: (1) a whole-brain irradiation comprised of two lateral beams at the 90 degree and 270 degree microRT treatment positions and (2) a hemispheric (left-brain) irradiation comprised of a single A-P vertex beam at the 0 degree microRT treatment position. During treatment, subject animals (n=48) were positioned to the CERR-generated treatment coordinates using the three-axis microRT motor positioning system and were irradiated using a clinical Ir-192 high-dose-rate remote after-loading system. The radiation treatment course consisted of 5 Gy fractions, 3 days per week. 90% of the subjects received a total dose of 30 Gy and 10% received a dose of 60 Gy. RESULTS: Image analysis verified the safety and reproducibility of the immobilizer. CT scans generated from repeated reloading and repositioning of the same subject animal in the couch-immobilizer assembly were fused to a baseline CT. The resultant analysis revealed a 0.09 mm average, center-of-mass translocation and negligible volumetric error in the contoured, murine brain. The experimental use of the head immobilizer added 0.1 mm to microRT spatial uncertainty along each axis. Overall, the total spatial uncertainty for the prescribed treatments was +/-0.3 mm in all three axes, a 0.2 mm functional improvement over the original version of microRT. Subject tolerance was good, with minimal observed side effects and a low procedure-induced mortality rate. Throughput was high, with average treatment times of 7.72 and 3.13 min/animal for the whole-brain and hemispheric plans, respectively (dependent on source strength). CONCLUSIONS: The method described exhibits conformality more in line with the size differential between human and animal patients than provided by previous prevalent approaches. Using pretreatment imaging and microRT-specific treatment planning, our method can deliver an accurate, conformal dose distribution to the targeted murine brain (or a subregion of the brain) while minimizing excess dose to the surrounding tissue. Thus, preclinical animal studies assessing the radiotherapeutic response of both normal and malignant CNS tissue to complex dose distributions, which closer resemble human-type radiotherapy, are better enabled. The procedural and mechanistic framework for this method logically provides for future adaptation into other murine target organs or regions.


Assuntos
Neoplasias Encefálicas/radioterapia , Radioterapia Conformacional/instrumentação , Radioterapia Conformacional/veterinária , Animais , Desenho de Equipamento , Análise de Falha de Equipamento , Estudos de Viabilidade , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Nus , Miniaturização
3.
Med Phys ; 34(12): 4738-49, 2007 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-18196801

RESUMO

Multimodality imaging information is regularly used now in radiotherapy treatment planning for cancer patients. The authors are investigating methods to take advantage of all the imaging information available for joint target registration and segmentation, including multimodality images or multiple image sets from the same modality. In particular, the authors have developed variational methods based on multivalued level set deformable models for simultaneous 2D or 3D segmentation of multimodality images consisting of combinations of coregistered PET, CT, or MR data sets. The combined information is integrated to define the overall biophysical structure volume. The authors demonstrate the methods on three patient data sets, including a nonsmall cell lung cancer case with PET/CT, a cervix cancer case with PET/CT, and a prostate patient case with CT and MRI. CT, PET, and MR phantom data were also used for quantitative validation of the proposed multimodality segmentation approach. The corresponding Dice similarity coefficient (DSC) was 0.90 +/- 0.02 (p < 0.0001) with an estimated target volume error of 1.28 +/- 1.23% volume. Preliminary results indicate that concurrent multimodality segmentation methods can provide a feasible and accurate framework for combining imaging data from different modalities and are potentially useful tools for the delineation of biophysical structure volumes in radiotherapy treatment planning.


Assuntos
Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Algoritmos , Feminino , Humanos , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/radioterapia , Imageamento por Ressonância Magnética , Masculino , Tomografia por Emissão de Pósitrons , Neoplasias da Próstata/diagnóstico , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Tomografia Computadorizada de Emissão de Fóton Único , Tomografia Computadorizada por Raios X , Neoplasias do Colo do Útero/diagnóstico , Neoplasias do Colo do Útero/diagnóstico por imagem , Neoplasias do Colo do Útero/radioterapia
4.
Radiother Oncol ; 81(3): 264-8, 2006 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17113668

RESUMO

BACKGROUND AND PURPOSE: To compare helical, MIP and AI 4D CT imaging, for the purpose of determining the best CT-based volume definition method for encompassing the mobile gross tumor volume (mGTV) within the planning target volume (PTV) for stereotactic body radiation therapy (SBRT) in stage I lung cancer. MATERIALS AND METHODS: Twenty patients with medically inoperable peripheral stage I lung cancer were planned for SBRT. Free-breathing helical and 4D image datasets were obtained for each patient. Two composite images, the MIP and AI, were automatically generated from the 4D image datasets. The mGTV contours were delineated for the MIP, AI and helical image datasets for each patient. The volume for each was calculated and compared using analysis of variance and the Wilcoxon rank test. A spatial analysis for comparing center of mass (COM) (i.e. isocenter) coordinates for each imaging method was also performed using multivariate analysis of variance. RESULTS: The MIP-defined mGTVs were significantly larger than both the helical- (p=0.001) and AI-defined mGTVs (p=0.012). A comparison of COM coordinates demonstrated no significant spatial difference in the x-, y-, and z-coordinates for each tumor as determined by helical, MIP, or AI imaging methods. CONCLUSIONS: In order to incorporate the extent of tumor motion from breathing during SBRT, MIP is superior to either helical or AI images for defining the mGTV. The spatial isocenter coordinates for each tumor were not altered significantly by the imaging methods.


Assuntos
Interpretação de Imagem Assistida por Computador , Neoplasias Pulmonares/radioterapia , Tomografia Computadorizada por Raios X , Humanos , Planejamento da Radioterapia Assistida por Computador , Respiração , Estudos Retrospectivos , Técnicas Estereotáxicas
5.
Radiother Oncol ; 93(1): 64-70, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19733408

RESUMO

BACKGROUND AND PURPOSE: The Tomotherapy Hi-Art II system allows acquisition of pre-treatment MVCT images to correct patient position. This work evaluates the dosimetric impact of uncorrected setup errors in breast-cancer radiation therapy. MATERIALS AND METHODS: Breast-cancer patient-positioning errors were simulated by shifting the patient computed-tomography (CT) dataset relative to the planned photon fluence and re-computing the dose distributions. To properly evaluate the superficial region, film measurements were compared against the Tomotherapy treatment planning system (TPS) calculations. A simulation of the integrated dose distribution was performed to evaluate the setup error impact over the course of treatment. RESULTS: Significant dose differences were observed for 11-mm shifts in the anterolateral and 3-mm shifts in the posteromedial directions. The results of film measurements in the superficial region showed that the TPS overestimated the dose by 14% at a 1-mm depth, improving to 3% at depths >or=5mm. Significant dose reductions in PTV were observed in the dose distributions simulated over the course of treatment. CONCLUSIONS: Tomotherapy's rotational delivery provides sufficient photon fluence extending beyond the skin surface to allow an up to 7-mm uncorrected setup error in the anterolateral direction. However, the steep dose falloff that conforms to the lung surface leads to compromised dose distributions with uncorrected posteromedial shifts. Therefore, daily image guidance and consequent patient repositioning is warranted for breast-cancer patients.


Assuntos
Neoplasias da Mama/radioterapia , Lesões por Radiação/prevenção & controle , Interpretação de Imagem Radiográfica Assistida por Computador , Planejamento da Radioterapia Assistida por Computador/métodos , Tomografia Computadorizada Espiral , Neoplasias da Mama/diagnóstico por imagem , Relação Dose-Resposta à Radiação , Feminino , Humanos , Erros Médicos , Radiometria , Dosagem Radioterapêutica , Técnicas de Imagem de Sincronização Respiratória , Medição de Risco , Sensibilidade e Especificidade , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA