1.
J Appl Clin Med Phys ; : e14391, 2024 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-38988053

RESUMO

In failure modes and effects analysis (FMEA), the components of the risk priority number (RPN) for a failure mode (FM) are often chosen by consensus. We describe an empirical method for estimating the occurrence (O) and detectability (D) components of a RPN. The method requires for a given FM that its associated quality control measure be performed twice as is the case when a FM is checked for in an initial physics check and again during a weekly physics check. If instances of the FM caught by these checks are recorded, O and D can be computed. Incorporation of the remaining RPN component, Severity, is discussed. This method can be used as part of quality management design ahead of an anticipated FMEA or afterwards to validate consensus values.

2.
J Appl Clin Med Phys ; 24(9): e13994, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37053047

RESUMO

This work of fiction is part of a case study series developed by the Medical Physics Leadership Academy (MPLA). It is intended to facilitate the discussion of the managerial and leadership challenges faced by a clinical medical physicist. In this case, a physicist David used to work in a clinic where he thrived and felt like a leader, despite not having the title. After a job change, he is now officially the "Lead Physicist" at a hospital newly affiliated with a large academic healthcare system. He believes he will be equally successful. Yet he struggles to bring about changes and get buy-in from coworkers. In the end, he feels like giving up and considers changing his job. This case is in the scenario of Problem Diagnosis.i The intended use of this case, through group discussion or self-study, is to encourage readers to perform a comprehensive analysis that identifies the root cause of the problem. This case study falls under the scope of and is supported by the MPLA, a committee in the American Association of Physicists in Medicine (AAPM).


Assuntos
Liderança , Medicina , Masculino , Humanos , Estados Unidos , Hospitais , Atenção à Saúde
3.
J Appl Clin Med Phys ; 24(8): e14089, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37415409

RESUMO

This work of fiction is part of a case study series developed by the Medical Physics Leadership Academy (MPLA). It is intended to facilitate the discussion of how students and advisors can better communicate expectations and navigate difficult conversations. In this case, a fourth-year Ph.D. student Emma learns that her advisor Dr. So is leaving the institution and has not arranged to bring any students with him. As Emma and Dr. So meet to discuss Emma's next steps, the conversation reveals misunderstandings and miscommunications of expectations, including a specific publication requirement for graduation from Dr. So. Having just learned of Dr. So's publication requirement, Emma realizes that graduating before the lab shuts down is not feasible. The intended use of this case, through group discussion or self-study, is to encourage readers to discuss the situation at hand and inspire professionalism and leadership thinking. This case study falls under the scope of and is supported by the MPLA, a committee in the American Association of Physicists in Medicine (AAPM).


Assuntos
Liderança , Motivação , Humanos , Masculino , Feminino , Estados Unidos , Estudantes , Aprendizagem
4.
J Appl Clin Med Phys ; 22(8): 280-283, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34196109

RESUMO

This work of fiction re-enacts a scenario in which a medical physics resident was not able to address a physics call during patient simulation and was criticized by the supervising faculty physicist in front of the team and the patient. The resident and the faculty agreed to meet afterwards to debrief the situation, in the hope of establishing a better working relationship. The intended use of this case, through group discussion, self-study, or role-play, is to encourage readers to discuss the situation at hand, inspire professionalism and leadership thinking, and allow the practice of conflict management. Facilitator's notes are available upon request to the MPLA Cases Subcommittee. This case study falls under the scope of and is supported by the Medical Physics Leadership Academy (MPLA), a committee in the American Association of Physicists in Medicine (AAPM).


Assuntos
Liderança , Física , Humanos , Estados Unidos
5.
J Appl Clin Med Phys ; 22(3): 251-253, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33739625

RESUMO

This fictional case describes the challenging situation for a junior physicist, who joined her hometown's cancer center as a solo physicist after graduating from residency. She is concerned about providing optimal patient care as well as improving her work/life balance. She wonders how to move forward. The intended use of the case study, in either a facilitated learning session or self-study, is to inspire the readers to discuss the situation, analyze the institutional and personal factors, apply relevant leadership skills, and propose action plans. This case study falls under the scope of, and is supported by, the Medical Physics Leadership Academy (MPLA). A sample facilitator's guide or self-study guide is available upon request to the MPLA Cases Subcommittee.


Assuntos
Internato e Residência , Liderança , Feminino , Humanos , Equilíbrio Trabalho-Vida , Fluxo de Trabalho
6.
J Appl Clin Med Phys ; 22(3): 246-250, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33739575

RESUMO

This fictional case describes a managerial situation of implementing cone-beam computed tomography faced by a solo medical physicist in a rural community hospital. The intended use of the case study, in either a facilitated learning session or self-study, is to inspire the readers to discuss the situation, analyze the institutional and personal factors, apply relevant leadership skills, and propose action plans. This case study falls under the scope of, and is supported by, the Medical Physics Leadership Academy (MPLA). A sample facilitator's guide or self-study guide is included in the manuscript for reference by users of this case study.


Assuntos
Hospitais Comunitários , Liderança , Tomografia Computadorizada de Feixe Cônico , Humanos
7.
J Appl Clin Med Phys ; 18(3): 52-55, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28370918

RESUMO

We present an example when profile measurement and modeling of an Elekta Agility multileaf collimator (MLC) had a large effect specifically on arc therapy plan quality assurance (QA) results using ArcCheck. ArcCheck absolute dose measurements of these plans were systematically lower than planned by 3-10%. Failing QA results were seen even with unmodulated static and conformal arcs. Furthermore, the effect was found to be dependent on collimator angle, with worse results associated with near-zero collimator angles. In contrast, step-and-shoot QA results were not affected. Changing the beam model to match steeper profile measurements obtained using a different measurement device resolved the problem. This case study demonstrates that conventional gamma index analysis can be sensitive to small profile modeling changes.


Assuntos
Aceleradores de Partículas , Garantia da Qualidade dos Cuidados de Saúde , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/instrumentação , Radioterapia de Intensidade Modulada/métodos , Planejamento da Radioterapia Assistida por Computador
11.
J Appl Clin Med Phys ; 16(1): 5090, 2015 Jan 08.
Artigo em Inglês | MEDLINE | ID: mdl-25679167

RESUMO

The purpose of this study was to evaluate proton depth dose perturbation caused by a radio-opaque hydrogel fiducial marker. Electronic proton stopping powers in the hydrogel were calculated for energies 0.5-250 MeV, and Monte Carlo simulations were generated of hydrogel vs. gold markers placed at various water phantom depths in a generic proton beam. Across the studied energy range, the gel/water stopping power ratio was 1.0146 to 1.0160. In the Monte Carlo simulation, the hydrogel marker caused no discernible perturbation of the proton percent depth-dose (PDD) curve. In contrast, the gold marker caused dose reductions of as much as 20% and dose shadowing regions as long as 6.5 cm. In contrast to gold markers, the radio-opaque hydrogel marker causes negligible proton depth dose perturbation. This factor may be taken into consideration for image-guided proton therapy at facilities with suitable imaging modalities.


Assuntos
Marcadores Fiduciais , Hidrogel de Polietilenoglicol-Dimetacrilato/química , Neoplasias/radioterapia , Prótons , Simulação por Computador , Ouro/química , Humanos , Método de Monte Carlo , Imagens de Fantasmas , Dosagem Radioterapêutica , Radioterapia Guiada por Imagem , Água/química
12.
J Appl Clin Med Phys ; 16(3): 4959, 2015 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-26103473

RESUMO

In electron and proton radiotherapy, applications of patient-specific electron bolus or proton compensators during radiation treatments are often necessary to accommodate patient body surface irregularities, tissue inhomogeneity, and variations in PTV depths to achieve desired dose distributions. Emerging 3D printing technologies provide alternative fabrication methods for these bolus and compensators. This study investigated the potential of utilizing 3D printing technologies for the fabrication of the electron bolus and proton compensators. Two printing technologies, fused deposition modeling (FDM) and selective laser sintering (SLS), and two printing materials, PLA and polyamide, were investigated. Samples were printed and characterized with CT scan and under electron and proton beams. In addition, a software package was developed to convert electron bolus and proton compensator designs to printable Standard Tessellation Language file format. A phantom scalp electron bolus was printed with FDM technology with PLA material. The HU of the printed electron bolus was 106.5 ± 15.2. A prostate patient proton compensator was printed with SLS technology and polyamide material with -70.1 ± 8.1 HU. The profiles of the electron bolus and proton compensator were compared with the original designs. The average over all the CT slices of the largest Euclidean distance between the design and the fabricated bolus on each CT slice was found to be 0.84 ± 0.45 mm and for the compensator to be 0.40 ± 0.42 mm. It is recommended that the properties of specific 3D printed objects are understood before being applied to radiotherapy treatments.


Assuntos
Elétrons , Impressão Tridimensional/instrumentação , Prótons , Radioterapia Conformacional/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Estudos de Viabilidade , Espalhamento de Radiação
14.
Pract Radiat Oncol ; 14(2): 112-132, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37977261

RESUMO

PURPOSE: This guideline provides evidence-based recommendations on appropriate indications and techniques for partial breast irradiation (PBI) for patients with early-stage invasive breast cancer and ductal carcinoma in situ. METHODS: ASTRO convened a task force to address 4 key questions focused on the appropriate indications and techniques for PBI as an alternative to whole breast irradiation (WBI) to result in similar rates of ipsilateral breast recurrence (IBR) and toxicity outcomes. Also addressed were aspects related to the technical delivery of PBI, including dose-fractionation regimens, target volumes, and treatment parameters for different PBI techniques. The guideline is based on a systematic review provided by the Agency for Healthcare Research and Quality. Recommendations were created using a predefined consensus-building methodology and system for grading evidence quality and recommendation strength. RESULTS: PBI delivered using 3-dimensional conformal radiation therapy, intensity modulated radiation therapy, multicatheter brachytherapy, and single-entry brachytherapy results in similar IBR as WBI with long-term follow-up. Some patient characteristics and tumor features were underrepresented in the randomized controlled trials, making it difficult to fully define IBR risks for patients with these features. Appropriate dose-fractionation regimens, target volume delineation, and treatment planning parameters for delivery of PBI are outlined. Intraoperative radiation therapy alone is associated with a higher IBR rate compared with WBI. A daily or every-other-day external beam PBI regimen is preferred over twice-daily regimens due to late toxicity concerns. CONCLUSIONS: Based on published data, the ASTRO task force has proposed recommendations to inform best clinical practices on the use of PBI.


Assuntos
Braquiterapia , Neoplasias da Mama , Carcinoma Intraductal não Infiltrante , Radioterapia Conformacional , Feminino , Humanos , Mama , Neoplasias da Mama/radioterapia , Estados Unidos , Revisões Sistemáticas como Assunto
15.
Oncology (Williston Park) ; 27(4): 329-42, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23781698

RESUMO

Breast-conserving therapy consisting of segmental mastectomy followed by whole-breast irradiation (WBI) has become widely accepted as an alternative to mastectomy as a treatment for women with early-stage breast cancer. Accelerated partial-breast irradiation (APBI) is a shorter, alternative radiation technique for select patients with favorable early-stage breast cancer. We review here the different modalities of APBI delivery and discuss the possible benefits and harms associated with these treatments.


Assuntos
Neoplasias da Mama/radioterapia , Braquiterapia , Mama/efeitos da radiação , Feminino , Custos de Cuidados de Saúde , Humanos , Guias de Prática Clínica como Assunto , Terapia com Prótons
16.
Med Dosim ; 2023 Nov 14.
Artigo em Inglês | MEDLINE | ID: mdl-37973476

RESUMO

The reporting of errors resulting in dose deviations are well-studied. Less studied is the amount of inconsequential errors that will not harm the patient but could lead to inefficiency. This paper reports an institutional effort to quantify and reduce these less significant errors. Dosimetry items discovered during physicist plan/record and verify (R&V) check prior to treatment were recorded in a shared document and called Therapy Anomaly Gathering System (THANGS) and individual items were called a "thang." Items were categorized to 1 of 4 types: Treatment Plan, Plan Document, R&V, and Secondary MU. The aggregate numbers were presented to the dosimetry staff at regular staff meetings. It was emphasized to the staff that this was a Quality Improvement (QI) study and would not be used punitively. Thangs were tracked over a 4-year period. In Q1 of year 1 of the study, the average number of errors identified was 179/month. This was reduced to 114/month by Q4 of year 1 and 68/month by the end of year 4, a 62% reduction. The number of errors/plan in Q1 Year 1 was 1.25, and that was reduced by Q4 Year 4 to 0.4, a 68% reduction. The percentage of errors by type did not vary much over the 4 years. By far, R&V errors were the most common, and QI efforts were primarily aimed at them. We have developed a simple method to identify areas in dosimetric work that are vulnerable to minor errors and, through consistent reminders, drastically reduce them. This leads to a seamless throughput for a given plan ultimately resulting in improved physics, therapist, and most importantly patient satisfaction.

19.
Pract Radiat Oncol ; 12(6): e547-e555, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35667552

RESUMO

PURPOSE: We report our experience of performing an extra, earlier physics plan check as recommended by the American Association of Physicists in Medicine Task Group 100 and Task Group 275 reports. We assessed utilization and timing of the extra check as well as the time required in a medium-sized clinic. METHODS AND MATERIALS: We retrospectively extracted and analyzed timestamp data from the record and verify system for the quality checklist (QCL) items related to treatment planning and physics "prechecks" for 3487 patients treated at our institution from February 2017 to February 2021. The dosimetry staff was interviewed for their perception of the value and efficacy of the practice. RESULTS: Physics prechecks were requested for 19.0% of plans. The number of requests declined from 43.9% of cases in 2017 to 18.4% in 2018. The introduction of automated plan-check tools and a dosimetrist checklist further contributed to a drop in number of precheck requests to 3.5% in 2019. For patients who received a physics precheck, the treatment planning process was a median 3.6 hours longer compared with those without (P < .001). A total of 12.9% of the precheck requests were canceled by the dosimetrist after waiting a median time of 5.3 hours. There was a strong positive correlation (0.899) between a precheck being requested and the time remaining until treatment start. Higher complexity plans and plans with a specific concern (eg, possible collision) were more likely to have a precheck requested. CONCLUSIONS: Physics prechecks have become standard practice for certain cases in our clinic. However, the perception in the department was that, as a universal practice, waiting for a precheck was not worth the time saved redoing work on the few cases in which an error was caught. Dosimetrist access to automated checking tools and checklists, which were motivated by the precheck process, contributed to this perception.


Assuntos
Física , Garantia da Qualidade dos Cuidados de Saúde , Humanos , Estudos Retrospectivos , Radiometria , Lista de Checagem , Planejamento da Radioterapia Assistida por Computador/métodos
20.
Int J Radiat Oncol Biol Phys ; 70(2): 619-25, 2008 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-18164869

RESUMO

PURPOSE: To compare localization of the lumpectomy cavity by using breast surface matching vs. clips for image-guided external beam accelerated partial breast irradiation. METHODS AND MATERIALS: Twenty-seven patients with breast cancer with two computed tomography (CT) scans each had three CT registrations performed: (1) to bony anatomy, (2) to the center of mass (COM) of surgical clips, and (3) to the breast surface. The cavity COM was defined in both the initial and second CT scans after each type of registration, and distances between COMs (DeltaCOM(Bone), DeltaCOM(Clips), and DeltaCOM(Surface)) were determined. Smaller DeltaCOMs were interpreted as better localizations. Correlation coefficients were calculated for DeltaCOM vs. several variables. RESULTS: The DeltaCOM(Bone) (mean, 7 +/- 2 [SD] mm) increased with breast volume (r = 0.4; p = 0.02) and distance from the chest wall (r = 0.5; p = 0.003). Relative to bony registration, clip registration provided better localization (DeltaCOM(Clips) < DeltaCOM(Bone)) in 25 of 27 cases. Breast surface matching improved cavity localization (DeltaCOM(Surface) < DeltaCOM(Bone)) in 19 of 27 cases. Mean improvements (DeltaCOM(Bone) - DeltaCOM(Clips or Surface)) were 4 +/- 3 and 2 +/- 4 mm, respectively. In terms of percentage of improvement ([DeltaCOM(Bone) - DeltaCOM(Clips or Surface)]/DeltaCOM(Bone)), only surface matching showed a correlation with breast volume. Clip localization outperformed surface registration for cavities located superior to the breast COM. CONCLUSIONS: Use of either breast surface or surgical clips as surrogates for the cavity results in improved localization in most patients compared with bony registration and may allow smaller planning target volume margins for external beam accelerated partial breast irradiation. Compared with surface registration, clip registration may be less sensitive to anatomic characteristics and therefore more broadly applicable.


Assuntos
Osso e Ossos/diagnóstico por imagem , Neoplasias da Mama/diagnóstico por imagem , Mamografia , Mastectomia Segmentar , Próteses e Implantes , Planejamento da Radioterapia Assistida por Computador/métodos , Neoplasias da Mama/radioterapia , Neoplasias da Mama/cirurgia , Feminino , Humanos , Radioterapia Conformacional , Instrumentos Cirúrgicos