Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 289
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Eur Radiol ; 33(1): 294-301, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35852576

RESUMO

OBJECTIVE: To describe the prevalence and consequences of incidental findings when implementing routine noncontrast CT prior to cardiac surgery. METHODS: In the multicenter randomized controlled CRICKET study, 862 adult patients scheduled for cardiac surgery were randomized 1:1 to undergo standard of care (SoC), which included a chest-radiograph, or an additional preoperative noncontrast chest CT-scan (SoC+CT). In this subanalysis, all incidental findings detected on the chest radiograph and CT-scan were analyzed. The influence of smoking status on incidental findings was also evaluated, adjusting for sex, age, and group allocation. RESULTS: Incidental findings were observed in 11.4% (n = 49) of patients in the SoC+CT group and in 3.7% (n = 16) of patients in the SoC-group (p < 0.001). The largest difference was observed in findings requiring follow-up (SoC+CT 7.7% (n = 33) vs SoC 2.3% (n = 10), p < 0.001). Clinically relevant findings changing the surgical approach or requiring specific treatment were observed in 10 patients (1.2%, SoC+CT: 1.6% SoC: 0.7%), including lung cancer in 0.5% of patients (n = 4) and aortic dilatation requiring replacement in 0.2% of patients (n = 2). Incidental findings were more frequent in patients who stopped smoking (OR 1.91, 1.03-3.63) or who actively smoked (OR 3.91, 1.85-8.23). CONCLUSIONS: Routine CT-screening increases the rate of incidental findings, mainly by identifying more pulmonary findings requiring follow-up. Incidental findings are more prevalent in patients with a history of smoking, and preoperative CT might increase the yield of identifying lung cancer in these patients. Incidental findings, but not specifically the use of routine CT, are associated with delay of surgery. KEY POINTS: • Clinically relevant incidental findings are identified more often after a routine preoperative CT-scan, when compared to a standard of care workup, with some findings changing patient management. • Patients with a history of smoking have a higher rate of incidental findings and a lung cancer rate comparable to that of lung cancer screening trials. • We observed no clear delay in the time to surgery when adding routine CT screening.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Gryllidae , Neoplasias Pulmonares , Adulto , Animais , Humanos , Achados Incidentais , Detecção Precoce de Câncer , Neoplasias Pulmonares/etiologia , Tomografia Computadorizada por Raios X/métodos , Procedimentos Cirúrgicos Cardíacos/efeitos adversos
2.
Eur Radiol ; 32(4): 2611-2619, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34783875

RESUMO

OBJECTIVES: To evaluate if routine screening for aortic calcification using unenhanced CT lowers the risk of stroke and alters the surgical approach in patients undergoing general cardiac surgery compared with standard of care (SoC). METHODS: In this prospective, multicenter, randomized controlled trial, adult patients scheduled for cardiac surgery from September 2014 to October 2019 were randomized 1:1 into two groups: SoC alone, including chest radiography, vs. SoC plus preoperative noncontrast CT. The primary endpoint was in-hospital perioperative stroke. Secondary endpoints were preoperative change of the surgical approach, in-hospital mortality, and postoperative delirium. The trial was halted halfway for expected futility, as the conditional power analysis showed a chance < 1% of finding the hypothesized effect. RESULTS: A total of 862 patients were evaluated (SoC-group: 433 patients (66 ± 11 years; 74.1% male) vs. SoC + CT-group: 429 patients (66 ± 10 years; 69.9% male)). The perioperative stroke rate (SoC + CT: 2.1%, 9/429 vs. SoC: 1.2%, 5/433, p = 0.27) and rate of changed surgical approach (SoC + CT: 4.0% (17/429) vs. SoC: 2.8% (12/433, p = 0.35) did not differ between groups. In-hospital mortality and postoperative delirium were comparable between groups. In the SoC + CT group, aortic calcification was observed on CT in the ascending aorta in 28% (108/380) and in the aortic arch in 70% (265/379). CONCLUSIONS: Preoperative noncontrast CT in cardiac surgery candidates did not influence the surgical approach nor the incidence of perioperative stroke compared with standard of care. Aortic calcification is a frequent finding on the CT scan in these patients but results in major surgical alterations to prevent stroke in only few patients. KEY POINTS: • Aortic calcification is a frequent finding on noncontrast computed tomography prior to cardiac surgery. • Routine use of noncontrast computed tomography does not often lead to a change of the surgical approach, when compared to standard of care. • No effect was observed on perioperative stroke after cardiac surgery when using routine noncontrast computed tomography screening on top of standard of care.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Gryllidae , Acidente Vascular Cerebral , Adulto , Animais , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Feminino , Humanos , Masculino , Estudos Prospectivos , Fatores de Risco , Acidente Vascular Cerebral/etiologia , Tomografia Computadorizada por Raios X/efeitos adversos
3.
Radiology ; 298(3): 486-491, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33346696

RESUMO

Background The Value-Based Healthcare (VBH) concept is designed to improve individual healthcare outcomes without increasing expenditure, and is increasingly being used to determine resourcing of and reimbursement for medical services. Radiology is a major contributor to patient and societal healthcare at many levels. Despite this, some VBH models do not acknowledge radiology's central role; this may have future negative consequences for resource allocation. Methods, findings and interpretation This multi-society paper, representing the views of Radiology Societies in Europe, the USA, Canada, Australia, and New Zealand, describes the place of radiology in VBH models and the health-care value contributions of radiology. Potential steps to objectify and quantify the value contributed by radiology to healthcare are outlined. Published under a CC BY 4.0 license.


Assuntos
Atenção à Saúde/normas , Radiologia/normas , Aquisição Baseada em Valor , Consenso , Controle de Custos , Atenção à Saúde/economia , Humanos , Internacionalidade , Radiologia/economia , Sociedades Médicas
4.
J Magn Reson Imaging ; 54(5): 1596-1605, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34056788

RESUMO

BACKGROUND: Exercise therapy is considered preferential treatment for patellar tendinopathy (PT). However, there is conflicting evidence for structural patellar tendon adaptation in response to exercise therapy and its association with symptoms is weak. PURPOSE: To assess the association between 1) T2* relaxation times and symptom severity; 2) baseline T2* and clinical outcome; and 3) longitudinal T2* changes and clinical outcome in athletes with PT performing exercise therapy. STUDY TYPE: Randomized controlled clinical trial. SUBJECTS: Seventy-six athletes (18-35 years) with clinically diagnosed and ultrasound-confirmed PT. FIELD STRENGTH/SEQUENCE: 3D gradient echo sequence (3.0 T). ASSESSMENT: Patients were enrolled in a randomized trial of progressive tendon-loading exercises (PTLE) versus eccentric exercise therapy (EET). Symptoms were assessed using the Victorian Institute of Sports Assessment (VISA-P) questionnaire. 3D-Ultrashort echo time (UTE)-MRI was acquired at baseline, 12 and 24 weeks. Voxel-wise T2* relaxation times were quantified using mono-exponential and bi-exponential models. T2* analysis was performed in three patellar tendon tissue compartments representing: aligned collagen, degenerative tissue, and interface. STATISTICAL TESTS: Adjusted general linear, mixed-linear models, and generalized estimating equations. RESULTS: We included 76 patients with PT (58 men, mean age 24 ± 4 years); 38 in the PTLE-group and 38 in the EET-group, of which 57 subjects remained eligible for analysis. T2* relaxation times were significantly associated with VISA-P in degenerative and interface tissues of the patellar tendon. No association was found between baseline T2* and VISA-P after 24 weeks (P > 0.29). The estimated mean T2* in degenerative tissue decreased from 14 msec (95%CI: 12-16) at baseline to 13 msec (95%CI: 11-15) at 12 weeks and to 13 msec (95%CI: 10-15) at 24 weeks. The significant decrease in T2* from baseline to 24 weeks was associated with improved clinical outcome. DATA CONCLUSION: Tissue-specific T2* relaxation times, identified with 3D-UTE-MRI, decreased significantly in athletes with patellar tendinopathy performing exercise therapy and this decrease was associated with improved clinical outcome. EVIDENCE LEVEL: 1 TECHNICAL EFFICACY: Stage 4.


Assuntos
Patela , Tendinopatia , Adulto , Terapia por Exercício , Humanos , Imageamento por Ressonância Magnética , Masculino , Estudos Prospectivos , Tendinopatia/diagnóstico por imagem , Tendinopatia/terapia , Adulto Jovem
5.
Eur Radiol ; 31(11): 8116-8129, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33895857

RESUMO

PURPOSE: Bicuspid aortic valve (BAV) is a complex malformation affecting not merely the aortic valve. However, little is known regarding the dynamic physiology of the aortic annulus in these patients and whether it is similar to tricuspid aortic valves (TAV). Determining the BAV annular plane is more challenging than for TAV. Our aim was to present a standardized methodology to determine BAV annulus and investigate its changes in shape and dimensions during the cardiac cycle. METHODS: BAV patients were prospectively included and underwent an ECG-gated cardiac CTA. The annulus plane was manually identified on reconstructions at 5% intervals of the cardiac cycle with a new standardized method for different BAV types. Based on semi-automatically defined contours, maximum and minimum diameter, area, area-derived diameter, perimeter, asymmetry ratio (AR), and relative area were calculated. Differences of dynamic annular parameters were assessed also per BAV type. RESULTS: Of the 55 patients included (38.4 ± 13.3 years; 58% males), 38 had BAV Sievers type 1, 10 type 0, and 7 type 2. The minimum diameter, perimeter, area, and area-derived diameter were significantly higher in systole than in diastole with a relative change of 13.7%, 4.8%, 13.7%, and 7.2% respectively (all p < 0.001). The AR was ≥ 1.1 in all phases, indicating an elliptic shape, with more pronounced flattening in diastole (p < 0.001). Different BAV types showed comparable dynamic changes. CONCLUSIONS: BAV annulus undergo significant changes in shape during the cardiac cycle with a wider area in systole and a more elliptic conformation in diastole regardless of valve type. KEY POINTS: • A refined method for the identification of the annulus plane on CT scans of patients with bicuspid aortic valves, tailored for the specific anatomy of each valve type, is proposed. • The annulus of patients with bicuspid aortic valves undergoes significant changes during the cardiac cycle with a wider area and more circular shape in systole regardless of valve type. • As compared to previously published data, the bicuspid aortic valve annulus has physiological dynamics similar to that encountered in tricuspid valves but with overall larger dimensions.


Assuntos
Estenose da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Doenças das Valvas Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Feminino , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/cirurgia , Humanos , Masculino
6.
J Vasc Interv Radiol ; 32(4): 497-503, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33526342

RESUMO

PURPOSE: To explore the association between baseline osteoarthritis (OA)-related magnetic resonance (MR) imaging features and pain reduction after genicular artery embolization (GAE) in patients with mild-to-moderate symptomatic knee OA resistant to conservative therapy. MATERIALS AND METHODS: This was a retrospective analysis of patients with mild-to-moderate symptomatic knee OA treated with GAE using imipenem-cilastatin sodium. The clinical outcome was scored at baseline and 6 months after treatment using the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC). MR images were scored using the MR imaging osteoarthritis knee score. Linear regression was used to evaluate associations of before-treatment MR imaging scores with WOMACpain and WOMACtotal reduction after 6 months. RESULTS: Fifty-four patients (22.2% male; median age, 69.4 years; median WOMACpain at baseline, 12) were evaluated. Of all OA features scored, a higher cartilage full-thickness defect score showed the strongest association with less reduction of both WOMACpain (B,-0.63 [95% confidence interval (CI), -0.91 to -0.34]; P < .001) and WOMACtotal scores (B, -1.77 [95% CI, -2.87 to -0.67]; P < .001) following treatment. The presence of grade 2-3 effusion synovitis (B, -2.99 [95% CI, -5.39 to -0.60]) bone marrow lesions (B, -0.52 [95% CI, -0.86 to -0.19]), osteophytes (B, -0.21 [95% CI, -0.36 to -0.06]), and cartilage defect surface area score (B, -0.25 [95% CI -0.42 to -0.08]) all showed a significant association with less WOMACpain reduction (all P < .05). CONCLUSIONS: In patients with mild-to-moderate symptomatic knee OA treated with GAE, the presence and severity of full-thickness cartilage defects, effusion synovitis, bone marrow lesions, osteophytes, and cartilage surface area scores at baseline are associated with less favorable clinical outcomes at 6 months.


Assuntos
Artralgia/terapia , Embolização Terapêutica , Articulação do Joelho/diagnóstico por imagem , Imageamento por Ressonância Magnética , Osteoartrite do Joelho/terapia , Idoso , Artralgia/diagnóstico por imagem , Artralgia/fisiopatologia , Embolização Terapêutica/efeitos adversos , Feminino , Humanos , Articulação do Joelho/fisiopatologia , Masculino , Pessoa de Meia-Idade , Osteoartrite do Joelho/diagnóstico por imagem , Osteoartrite do Joelho/fisiopatologia , Medição da Dor , Valor Preditivo dos Testes , Estudos Retrospectivos , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento
7.
J Nucl Cardiol ; 28(5): 2072-2082, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-31792918

RESUMO

BACKGROUNDS: Transcatheter-implanted aortic valve infective endocarditis (TAVI-IE) is difficult to diagnose when relying on the Duke Criteria. Our aim was to assess the additional diagnostic value of 18F-fluorodeoxyglucose (18F-FDG) positron emission/computed tomography (PET/CT) and cardiac computed tomography angiography (CTA) in suspected TAVI-IE. METHODS: A multicenter retrospective analysis was performed in all patients who underwent 18F-FDG-PET/CT and/or CTA with suspected TAVI-IE. Patients were first classified with Duke Criteria and after adding 18F-FDG-PET/CT and CTA, they were classified with European Society of Cardiology (ESC) criteria. The final diagnosis was determined by our Endocarditis Team based on ESC guideline recommendations. RESULTS: Thirty patients with suspected TAVI-IE were included. 18F-FDG-PET/CT was performed in all patients and Cardiac CTA in 14/30. Using the Modified Duke Criteria, patients were classified as 3% rejected (1/30), 73% possible (22/30), and 23% definite (7/30) TAVI-IE. Adding 18F-FDG-PET/CT and CTA supported the reclassification of 10 of the 22 possible cases as "definite TAVI-IE" (5/22) or "rejected TAVI-IE" (5/22). This changed the final diagnosis to 20% rejected (6/30), 40% possible (12/30), and 40% definite (12/30) TAVI-IE. CONCLUSIONS: Addition of 18F-FDG-PET/CT and/or CTA changed the final diagnosis in 33% of patients and proved to be a valuable diagnostic tool in patients with suspected TAVI-IE.


Assuntos
Endocardite/diagnóstico por imagem , Fluordesoxiglucose F18/uso terapêutico , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/normas , Tomografia Computadorizada por Raios X/normas , Idoso , Idoso de 80 Anos ou mais , Endocardite/cirurgia , Feminino , Humanos , Masculino , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/tendências , Estudos Retrospectivos , Estatísticas não Paramétricas , Tomografia Computadorizada por Raios X/métodos , Tomografia Computadorizada por Raios X/tendências , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/estatística & dados numéricos
8.
Br J Sports Med ; 55(9): 501-509, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33219115

RESUMO

OBJECTIVE: To compare the effectiveness of progressive tendon-loading exercises (PTLE) with eccentric exercise therapy (EET) in patients with patellar tendinopathy (PT). METHODS: In a stratified, investigator-blinded, block-randomised trial, 76 patients with clinically diagnosed and ultrasound-confirmed PT were randomly assigned in a 1:1 ratio to receive either PTLE or EET. The primary end point was clinical outcome after 24 weeks following an intention-to-treat analysis, as assessed with the validated Victorian Institute of Sports Assessment for patellar tendons (VISA-P) questionnaire measuring pain, function and ability to play sports. Secondary outcomes included the return to sports rate, subjective patient satisfaction and exercise adherence. RESULTS: Patients were randomised between January 2017 and July 2019. The intention-to-treat population (mean age, 24 years, SD 4); 58 (76%) male) consisted of patients with mostly chronic PT (median symptom duration 2 years). Most patients (82%) underwent prior treatment for PT but failed to recover fully. 38 patients were randomised to the PTLE group and 38 patients to the EET group. The improvement in VISA-P score was significantly better for PTLE than for EET after 24 weeks (28 vs 18 points, adjusted mean between-group difference, 9 (95% CI 1 to 16); p=0.023). There was a trend towards a higher return to sports rate in the PTLE group (43% vs 27%, p=0.13). No significant between-group difference was found for subjective patient satisfaction (81% vs 83%, p=0.54) and exercise adherence between the PTLE group and EET group after 24 weeks (40% vs 49%, p=0.33). CONCLUSIONS: In patients with PT, PTLE resulted in a significantly better clinical outcome after 24 weeks than EET. PTLE are superior to EET and are therefore recommended as initial conservative treatment for PT.


Assuntos
Terapia por Exercício/métodos , Patela , Tendinopatia/terapia , Adulto , Terapia por Exercício/estatística & dados numéricos , Feminino , Humanos , Análise de Intenção de Tratamento , Masculino , Países Baixos , Medição da Dor , Patela/diagnóstico por imagem , Cooperação do Paciente , Satisfação do Paciente , Volta ao Esporte/estatística & dados numéricos , Método Simples-Cego , Tendinopatia/diagnóstico por imagem , Resultado do Tratamento , Ultrassonografia , Adulto Jovem
9.
Can Assoc Radiol J ; 72(2): 208-214, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33345576

RESUMO

BACKGROUND: The Value-Based Healthcare (VBH) concept is designed to improve individual healthcare outcomes without increasing expenditure, and is increasingly being used to determine resourcing of and reimbursement for medical services. Radiology is a major contributor to patient and societal healthcare at many levels. Despite this, some VBH models do not acknowledge radiology's central role; this may have future negative consequences for resource allocation. METHODS, FINDINGS AND INTERPRETATION: This multi-society paper, representing the views of Radiology Societies in Europe, the USA, Canada, Australia, and New Zealand, describes the place of radiology in VBH models and the health-care value contributions of radiology. Potential steps to objectify and quantify the value contributed by radiology to healthcare are outlined.


Assuntos
Atenção à Saúde/economia , Custos de Cuidados de Saúde , Radiologia/economia , Radiologia/métodos , Austrália , Canadá , Europa (Continente) , Humanos , Nova Zelândia , Sociedades Médicas , Estados Unidos
10.
J Magn Reson Imaging ; 52(2): 420-430, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32108398

RESUMO

BACKGROUND: Quantitative MRI of patellar tendinopathy (PT) can be challenging due to spatial variation of T2 * relaxation times. PURPOSE: 1) To compare T2 * quantification using a standard approach with analysis in specific tissue compartments of the patellar tendon. 2) To evaluate test-retest reliability of different methods for fitting ultrashort echo time (UTE)-relaxometry data. STUDY TYPE: Prospective. SUBJECTS: Sixty-five athletes with PT. FIELD STRENGTH/SEQUENCE: 3D UTE scans covering the patellar tendon were acquired using a 3.0T scanner and a 16-channel surface coil. ASSESSMENT: Voxelwise median T2 * was quantified with monoexponential, fractional-order, and biexponential fitting. We applied two methods for T2 * analysis: first, a standard approach by analyzing all voxels covering the proximal patellar tendon. Second, within subregions of the patellar tendon, by using thresholds on biexponential fitting parameter percentage short T2 * (0-30% for mostly long T2 *, 30-60% for mixed T2 *, and 60-100% for mostly short T2 *). STATISTICAL TESTS: Average test-retest reliability was assessed in three athletes using coefficients-of-variation (CV) and coefficients-of-repeatability (CR). RESULTS: With standard image analysis, we found a median [interquartile range, IQR] monoexponential T2 * of 6.43 msec [4.32-8.55] and fractional order T2 * 4.39 msec [3.06-5.78]. The percentage of short T2 * components was 52.9% [35.5-69.6]. Subregional monoexponential T2 * was 13.78 msec [12.11-16.46], 7.65 msec [6.49-8.61], and 3.05 msec [2.52-3.60] and fractional order T2 * 11.82 msec [10.09-14.44], 5.14 msec [4.25-5.96], and 2.19 msec [1.82-2.64] for 0-30%, 30-60%, and 60-100% short T2 *, respectively. Biexponential component short T2 * was 1.693 msec [1.417-2.003] for tissue with mostly short T2 * and long T2 * of 15.79 msec [13.47-18.61] for mostly long T2 *. The average CR (CV) was 2 msec (15%), 2 msec (19%) and 10% (22%) for monoexponential, fractional order and percentage short T2 *, respectively. DATA CONCLUSION: Patellar tendinopathy is characterized by regional variability in binding states of water. Quantitative multicompartment T2 * analysis in PT can be facilitated using a voxel selection method based on using biexponential fitting parameters. LEVEL OF EVIDENCE: 1 TECHNICAL EFFICACY STAGE: 1 J. Magn. Reson. Imaging 2020;52:420-430.


Assuntos
Imageamento por Ressonância Magnética , Tendinopatia , Biomarcadores , Humanos , Estudos Prospectivos , Reprodutibilidade dos Testes , Tendinopatia/diagnóstico por imagem
11.
BJU Int ; 126(1): 124-132, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32232921

RESUMO

OBJECTIVES: To investigate whether serial prostate magnetic resonance imaging (MRI) may guide the utility of repeat targeted (TBx) and systematic biopsy (SBx) when monitoring men with low-risk prostate cancer (PCa) at 1-year of active surveillance (AS). PATIENTS AND METHODS: We retrospectively included 111 consecutive men with low-risk (International Society of Urological Pathology [ISUP] Grade 1) PCa, who received protocolled repeat MRI with or without TBx and repeat SBx at 1-year of AS. TBx was performed in Prostate Imaging-Reporting and Data System (PI-RADS) score ≥3 lesions (MRI-positive men). Upgrading defined as ISUP Grade ≥2 PCa (I), Grade ≥2 with cribriform growth/intraductal carcinoma PCa (II), and Grade ≥3 PCa (III) was investigated. Upgrading detected by TBx only (not by SBx) and SBx only (not by TBx) was investigated in MRI-positive and -negative men, and related to radiological progression on MRI (Prostate Cancer Radiological Estimation of Change in Sequential Evaluation [PRECISE] score). RESULTS: Overall upgrading (I) was 32% (35/111). Upgrading in MRI-positive and -negative men was 48% (30/63) and 10% (5/48) (P < 0.001), respectively. In MRI-positive men, there was upgrading in 23% (seven of 30) by TBx only and in 33% (10/30) by SBx only. Radiological progression (PRECISE score 4-5) in MRI-positive men was seen in 27% (17/63). Upgrading (I) occurred in 41% (seven of 17) of these MRI-positive men, while this was 50% (23/46) in MRI-positive men without radiological progression (PRECISE score 1-3) (P = 0.534). Overall upgrading (II) was 15% (17/111). Upgrading in MRI-positive and -negative men was 22% (14/63) and 6% (three of 48) (P = 0.021), respectively. In MRI-positive men, there was upgrading in three of 14 by TBx only and in seven of 14 by SBx only. Overall upgrading (III) occurred in 5% (five of 111). Upgrading in MRI-positive and -negative men was 6% (four of 63) and 2% (one of 48) (P = 0.283), respectively. In MRI-positive men, there was upgrading in one of four by TBx only and in two of four by SBx only. CONCLUSION: Upgrading is significantly lower in MRI-negative compared to MRI-positive men with low-risk PCa at 1-year of AS. In serial MRI-negative men, the added value of repeat SBx at 1-year surveillance is limited and should be balanced individually against the harms. In serial MRI-positive men, the added value of repeat SBx is substantial. Based on this cohort, SBx is recommended to be performed in combination with TBx in all MRI-positive men at 1-year of AS, also when there is no radiological progression.


Assuntos
Biópsia/métodos , Biópsia Guiada por Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Estadiamento de Neoplasias/métodos , Próstata/patologia , Neoplasias da Próstata/diagnóstico , Idoso , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
12.
Recent Results Cancer Res ; 216: 31-110, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32594384

RESUMO

Imaging in Oncology is rapidly moving from the detection and size measurement of a lesion to the quantitative assessment of metabolic processes and cellular and molecular interactions. Increasing insights into cancer as a complex disease with involvement of the tumor stroma in tumor pathobiological processes have made it clear that for successful control of cancer, treatment strategies should not only be directed at the cancer cells but should also take aspects of the tumor microenvironment into account. This requires an understanding of the complex molecular and cellular interactions in cancer tissue. Recent developments in imaging technology have increased the possibility to image various pathobiological processes in cancer development and response to treatment. For computed tomography (CT) and magnetic resonance imaging (MRI) various improvements in hardware, software, and imaging probes have lifted these modalities from classical anatomical imaging techniques to techniques suitable to image and quantify various physiological processes and molecular and cellular interactions. Next to a more general overview of possible imaging targets in oncology, this chapter provides an overview of the various developments in CT and MRI technology and some specific applications.


Assuntos
Imageamento por Ressonância Magnética , Neoplasias/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Humanos , Oncologia
13.
Eur Radiol ; 30(11): 5942-5951, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32500197

RESUMO

OBJECTIVES: (1) To determine the association between patellar tendon stiffness and the presence of patellar tendinopathy (PT). (2) To evaluate the reliability of shear-wave elastography (SWE). METHODS: Participants were consecutively enrolled between January 2017 and June 2019. PT was diagnosed clinically and confirmed by either grayscale US or power Doppler US, or both. Controls had no history of anterior knee pain and no clinical signs of PT. Patellar tendon stiffness (kilopascal, kPa) was assessed using SWE. Logistic regression was used to estimate adjusted odds ratios (ORs) and 95% confidence intervals (CIs). Reliability analyses included coefficients-of-variation (CV), coefficients-of-repeatability (CR), intraclass correlation coefficient (ICC) for intraobserver and interobserver reliability, and Bland-Altman analysis. RESULTS: In total, 76 participants with PT (58 men, mean age 24.4 ± 3.8 years) and 35 asymptomatic controls (16 men, mean age 21.5 ± 3.8 years) were included. Univariate analyses (OR 1.094, 95% CI 1.061-1.128, p < .001) and adjusted multivariate analyses (OR 1.294, 95% CI 1.044-1.605, p = .018) showed that athletes with PT had significantly increased patellar tendon stiffness. ICC for intraobserver reliability was 0.95 (95% CI 0.92-0.97), CR (CV) 12 kPa (10%) and 0.79 (95% CI 0.65-0.88), CR (CV) 18 kPa (21%) for interobserver reliability. Mean differences from Bland-Altman analysis were 5.6 kPa (95% CI 3.1-8.1, p < .001) for intraobserver reliability and 4.6 kPa (95% CI 1.9-7.2, p < .001) for interobserver reliability. CONCLUSIONS: PT is associated with significantly higher patellar tendon stiffness. SWE measurements demonstrate excellent intraobserver reliability and good interobserver reliability. Therefore, SWE is a promising tool to implement in longitudinal studies and future studies should evaluate its prognostic value and utility as a monitoring tool in athletes with PT. KEY POINTS: • Patellar tendon stiffness measured with shear-wave elastography (SWE) is higher in athletes with patellar tendinopathy than in healthy controls, also after adjusting for potential confounders. • Excellent intraobserver reliability and good interobserver reliability were found for the quantitative assessment of patellar tendon stiffness using SWE.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Ligamento Patelar/diagnóstico por imagem , Tendinopatia/diagnóstico , Adolescente , Adulto , Atletas , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Adulto Jovem
14.
Eur Radiol ; 30(12): 6582-6592, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32594208

RESUMO

OBJECTIVES: To develop an automatic method for identification and segmentation of clinically significant prostate cancer in low-risk patients and to evaluate the performance in a routine clinical setting. METHODS: A consecutive cohort (n = 292) from a prospective database of low-risk patients eligible for the active surveillance was selected. A 3-T multi-parametric MRI at 3 months after inclusion was performed. Histopathology from biopsies was used as reference standard. MRI positivity was defined as PI-RADS score ≥ 3, histopathology positivity was defined as ISUP grade ≥ 2. The selected cohort contained four patient groups: (1) MRI-positive targeted biopsy-positive (n = 116), (2) MRI-negative systematic biopsy-negative (n = 55), (3) MRI-positive targeted biopsy-negative (n = 113), (4) MRI-negative systematic biopsy-positive (n = 8). Group 1 was further divided into three sets and a 3D convolutional neural network was trained using different combinations of these sets. Two MRI sequences (T2w, b = 800 DWI) and the ADC map were used as separate input channels for the model. After training, the model was evaluated on the remaining group 1 patients together with the patients of groups 2 and 3 to identify and segment clinically significant prostate cancer. RESULTS: The average sensitivity achieved was 82-92% at an average specificity of 43-76% with an area under the curve (AUC) of 0.65 to 0.89 for different lesion volumes ranging from > 0.03 to > 0.5 cc. CONCLUSIONS: The proposed deep learning computer-aided method yields promising results in identification and segmentation of clinically significant prostate cancer and in confirming low-risk cancer (ISUP grade ≤ 1) in patients on active surveillance. KEY POINTS: • Clinically significant prostate cancer identification and segmentation on multi-parametric MRI is feasible in low-risk patients using a deep neural network. • The deep neural network for significant prostate cancer localization performs better for lesions with larger volumes sizes (> 0.5 cc) as compared to small lesions (> 0.03 cc). • For the evaluation of automatic prostate cancer segmentation methods in the active surveillance cohort, the large discordance group (MRI positive, targeted biopsy negative) should be included.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética Multiparamétrica , Reconhecimento Automatizado de Padrão , Próstata/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Idoso , Algoritmos , Área Sob a Curva , Biópsia , Estudos de Coortes , Aprendizado Profundo , Humanos , Masculino , Pessoa de Meia-Idade , Redes Neurais de Computação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
15.
Eur Radiol ; 30(3): 1644-1652, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31802213

RESUMO

Women in Focus: Be Inspired was a unique programme held at the 2019 European Congress of Radiology that was structured to address a range of topics related to gender and healthcare, including leadership, mentoring and the generational progression of women in medicine. In most countries, women constitute substantially fewer than half of radiologists in academia or private practice despite frequently accounting for at least half of medical school enrolees. Furthermore, the proportion of women decreases at higher academic ranks and levels of leadership, a phenomenon which has been referred to as a "leaky pipeline". Gender diversity in the radiologic workplace, including in academic and leadership positions, is important for the present and future success of the field. It is a tool for excellence that helps to optimize patient care and research; moreover, it is essential to overcome the current shortage of radiologists. This article reviews the current state of gender diversity in academic and leadership positions in radiology internationally and explores a wide range of potential reasons for gender disparities, including the lack of role models and mentorship, unconscious bias and generational changes in attitudes about the desirability of leadership positions. Strategies for both individuals and institutions to proactively increase the representation of women in academic and leadership positions are suggested. KEY POINTS: • Gender-diverse teams perform better. Thus, gender diversity throughout the radiologic workplace, including in leadership positions, is important for the current and future success of the field. • Though women now make up roughly half of medical students, they remain underrepresented among radiology trainees, faculty and leaders. • Factors leading to the gender gap in academia and leadership positions in Radiology include a lack of role models and mentors, unconscious biases, other societal barriers and generational changes.


Assuntos
Liderança , Médicas/tendências , Radiologistas/tendências , Radiologia/organização & administração , Feminino , Humanos
16.
Eur Radiol ; 30(6): 3401-3408, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32064564

RESUMO

OBJECTIVE: Infrapatellar fat pad (IPFP) fat-suppressed T2 (T2FS) hyperintense regions on MRI are an important imaging feature of knee osteoarthritis (OA) and are thought to represent inflammation. These regions are also common in non-OA subjects, and may not always be linked to inflammation. Our aim was to evaluate quantitative blood perfusion parameters, as surrogate measure of inflammation, within T2FS-hyperintense regions in patients with OA, with patellofemoral pain (PFP) (supposed OA precursor), and control subjects. METHODS: Twenty-two knee OA patients, 35 PFP patients and 43 healthy controls were included and underwent MRI, comprising T2 and DCE-MRI sequences. T2FS-hyperintense IPFP regions were delineated and a reference region was drawn in adjacent IPFP tissue with normal signal intensity. After fitting the extended Tofts pharmacokinetic model, quantitative DCE-MRI perfusion parameters were compared between the two regions within subjects in each subgroup, using a paired Wilcoxon signed-rank test. RESULTS: T2FS-hyperintense IPFP regions were present in 16 of 22 (73%) OA patients, 13 of 35 (37%) PFP patients, and 14 of 43 (33%) controls. DCE-MRI perfusion parameters were significantly different between regions with and without a T2FS-hyperintense signal in OA patients, demonstrating higher Ktrans compared to normal IFPF tissue (0.039 min-1 versus 0.025 min-1, p = 0.017) and higher Ve (0.157 versus 0.119, p = 0.010). For PFP patients and controls no significant differences were found. CONCLUSIONS: IPFP T2FS-hyperintense regions are associated with higher perfusion in knee OA patients in contrast to identically appearing regions in PFP patients and controls, pointing towards an inflammatory pathogenesis in OA only. KEY POINTS: • Morphologically identical appearing T2FS-hyperintense infrapatellar fat pad regions show different perfusion in healthy subjects, subjects with patellofemoral pain, and subjects with knee osteoarthritis. • Elevated DCE-MRI perfusion parameters within T2FS-hyperintense infrapatellar fat pad regions in patients with osteoarthritis suggest an inflammatory pathogenesis in osteoarthritis, but not in patellofemoral pain and healthy subjects.


Assuntos
Tecido Adiposo/diagnóstico por imagem , Articulação do Joelho/diagnóstico por imagem , Osteoartrite do Joelho/diagnóstico por imagem , Síndrome da Dor Patelofemoral/diagnóstico por imagem , Tecido Adiposo/irrigação sanguínea , Adulto , Idoso , Estudos de Casos e Controles , Meios de Contraste , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
17.
Circulation ; 138(14): 1412-1427, 2018 10 02.
Artigo em Inglês | MEDLINE | ID: mdl-30018167

RESUMO

BACKGROUND: 18F-Fluorodeoxyglucose (FDG) positron-emission tomography/computed tomography (PET/CT) was recently introduced as a new tool for the diagnosis of prosthetic heart valve endocarditis (PVE). Previous studies reporting a modest diagnostic accuracy may have been hampered by unstandardized image acquisition and assessment, and several confounders, as well. The aim of this study was to improve the diagnostic performance of FDG PET/CT in patients in whom PVE was suspected by identifying and excluding possible confounders, using both visual and standardized quantitative assessments. METHODS: In this multicenter study, 160 patients with a prosthetic heart valve (median age, 62 years [43-73]; 68% male; 82 mechanical valves; 62 biological; 9 transcatheter aortic valve replacements; 7 other) who underwent FDG PET/CT for suspicion of PVE, and 77 patients with a PV (median age, 73 years [65-77]; 71% male; 26 mechanical valves; 45 biological; 6 transcatheter aortic valve replacements) who underwent FDG PET/CT for other indications (negative control group), were retrospectively included. Their scans were reassessed by 2 independent observers blinded to all clinical data, both visually and quantitatively on available European Association of Nuclear Medicine Research Ltd-standardized reconstructions. Confounders were identified by use of a logistic regression model and subsequently excluded. RESULTS: Visual assessment of FDG PET/CT had a sensitivity/specificity/positive predictive value/negative predictive value for PVE of 74%/91%/89%/78%, respectively. Low inflammatory activity (C-reactive protein <40 mg/L) at the time of imaging and use of surgical adhesives during prosthetic heart valve implantation were significant confounders, whereas recent valve implantation was not. After the exclusion of patients with significant confounders, diagnostic performance values of the visual assessment increased to 91%/95%/95%/91%. As a semiquantitative measure of FDG uptake, a European Association of Nuclear Medicine Research Ltd-standardized uptake value ratio of ≥2.0 was a 100% sensitive and 91% specific predictor of PVE. CONCLUSIONS: Both visual and quantitative assessments of FDG PET/CT have a high diagnostic accuracy in patients in whom PVE is suspected. FDG PET/CT should be implemented early in the diagnostic workup to prevent the negative confounding effects of low inflammatory activity (eg, attributable to prolonged antibiotic therapy). Recent valve implantation was not a significant predictor of false-positive interpretations, but surgical adhesives used during implantation were.


Assuntos
Endocardite Bacteriana/diagnóstico por imagem , Fluordesoxiglucose F18/administração & dosagem , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas/efeitos adversos , Valvas Cardíacas/cirurgia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Infecções Relacionadas à Prótese/diagnóstico por imagem , Compostos Radiofarmacêuticos/administração & dosagem , Adulto , Idoso , Endocardite Bacteriana/microbiologia , Feminino , Valvas Cardíacas/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Países Baixos , Variações Dependentes do Observador , Valor Preditivo dos Testes , Infecções Relacionadas à Prótese/microbiologia , Reprodutibilidade dos Testes , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Resultado do Tratamento
18.
Eur Heart J ; 39(41): 3739-3749, 2018 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-29351615

RESUMO

The timely diagnosis of prosthetic heart valve endocarditis remains challenging yet of utmost importance. 18F-fluorodeoxyglucose (18 F-FDG) positron emission/computed tomography (PET/CT) and cardiac computed tomography angiography (CTA) were recently introduced as additional diagnostic tools in the most recent ESC guidelines on infective endocarditis. However, how to interpret PET/CT findings with regard to what is to be considered abnormal, what the potential confounders may be, as well as which patients benefit most from these additional imaging techniques and how to best perform them in these often-complex patients, remains unclear. This review focusses on factors regarding patient selection and image acquisition that need to be taken into account when employing 18F-FDG PET/CT and CTA in daily clinical practice, and the importance of a multidisciplinary Endocarditis Team herein. Furthermore, it emphasizes the need for standardized acquisition protocols and image interpretation, especially now that these techniques are starting to be widely embraced by the cardiovascular society.


Assuntos
Técnicas de Imagem Cardíaca , Endocardite Bacteriana/diagnóstico por imagem , Próteses Valvulares Cardíacas/efeitos adversos , Infecções Relacionadas à Prótese/diagnóstico por imagem , Angiografia por Tomografia Computadorizada , Fluordesoxiglucose F18/administração & dosagem , Fluordesoxiglucose F18/uso terapêutico , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Guias de Prática Clínica como Assunto
19.
Radiology ; 289(3): 658-667, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30251930

RESUMO

Purpose To compare the diagnostic performance of minimally invasive autopsy with that of conventional autopsy. Materials and Methods For this prospective, single-center, cross-sectional study in an academic hospital, 295 of 2197 adult cadavers (mean age: 65 years [range, 18-99 years]; age range of male cadavers: 18-99 years; age range of female cadavers: 18-98 years) who died from 2012 through 2014 underwent conventional autopsy. Family consent for minimally invasive autopsy was obtained for 139 of the 295 cadavers; 99 of those 139 cadavers were included in this study. Those involved in minimally invasive autopsy and conventional autopsy were blinded to each other's findings. The minimally invasive autopsy procedure combined postmortem MRI, CT, and CT-guided biopsy of main organs and pathologic lesions. The primary outcome measure was performance of minimally invasive autopsy and conventional autopsy in establishing immediate cause of death, as compared with consensus cause of death. The secondary outcome measures were diagnostic yield of minimally invasive autopsy and conventional autopsy for all, major, and grouped major diagnoses; frequency of clinically unsuspected findings; and percentage of answered clinical questions. Results Cause of death determined with minimally invasive autopsy and conventional autopsy agreed in 91 of the 99 cadavers (92%). Agreement with consensus cause of death occurred in 96 of 99 cadavers (97%) with minimally invasive autopsy and in 94 of 99 cadavers (95%) with conventional autopsy (P = .73). All 288 grouped major diagnoses were related to consensus cause of death. Minimally invasive autopsy enabled diagnosis of 259 of them (90%) and conventional autopsy 224 (78%); 200 (69%) were found with both methods. At clinical examination, the cause of death was not suspected in 17 of the 99 cadavers (17%), and 124 of 288 grouped major diagnoses (43%) were not established. There were 219 additional clinical questions; 189 (86%) were answered with minimally invasive autopsy and 182 (83%) were answered with conventional autopsy (P = .35). Conclusion The performance of minimally invasive autopsy in the detection of cause of death was similar to that of conventional autopsy; however, minimally invasive autopsy has a higher yield of diagnoses. © RSNA, 2018 Online supplemental material is available for this article. See also the editorial by Krombach in this issue.


Assuntos
Autopsia/métodos , Causas de Morte , Imageamento por Ressonância Magnética/métodos , Radiografia Intervencionista/métodos , Tomografia Computadorizada por Raios X/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Cadáver , Estudos Transversais , Feminino , Humanos , Biópsia Guiada por Imagem/métodos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Adulto Jovem
20.
J Magn Reson Imaging ; 48(5): 1344-1350, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-29734499

RESUMO

BACKGROUND: Altered perfusion might play an important role in the pathophysiology of patellofemoral pain (PFP), a common knee complaint with unclear pathophysiology. PURPOSE: To investigate differences in dynamic contrast-enhanced (DCE)-MRI perfusion parameters between patients with PFP and healthy control subjects. POPULATION/SUBJECTS/PHANTOM/SPECIMEN/ANIMAL MODEL: Thirty-five adult patients with PFP and 44 healthy adult control subjects. FIELD STRENGTH/SEQUENCE: 3T DCE-MRI consisting of a sagittal, anterior-posterior, frequency-encoded, fat-suppressed 3D spoiled gradient-echo sequence with intravenous contrast administration. ASSESSMENT: Patellar bone volumes of interest (VOIs) were delineated by a blinded observer. Quantitative perfusion parameters (kep and ktrans ) were calculated from motion-compensated DCE-MRI data by fitting Tofts' model. Weighted mean and unweighted median values of kep and ktrans were computed within the patellar bone VOIs. STATISTICAL TESTS: Differences in patellar bone perfusion parameters were compared between groups by linear regression analyses, adjusted for confounders. RESULTS: Mean differences of weighted mean and unweighted median were 0.0039 (95% confidence interval [CI] -0.0013; 0.0091) and 0.0052 (95% CI -0.0078; 0.018) for ktrans , and 0.046 (95% CI -0.021; 0.11) and 0.069 (95% CI -0.017; 0.15) for kep , respectively. All perfusion parameters were not significantly different between groups (P-values: 0.32; 0.47 for ktrans , and 0.24; 0.15) for kep . However, a significant difference in variance between populations was observed for ktrans (P-value 0.007). DATA CONCLUSION: Higher patellar bone perfusion parameters were found in patients with PFP when compared to healthy control subjects, but these differences were not statistically significant. This result, and the observed significant difference in ktrans variance, warrant further research. LEVEL OF EVIDENCE: 1 Technical Efficacy: Stage 3 J. Magn. Reson. Imaging 2018;47:1344-1350.


Assuntos
Meios de Contraste/química , Fêmur/diagnóstico por imagem , Imageamento por Ressonância Magnética , Dor/diagnóstico por imagem , Patela/diagnóstico por imagem , Adolescente , Adulto , Estudos de Casos e Controles , Humanos , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Perfusão , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA