Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Sensors (Basel) ; 23(13)2023 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-37447663

RESUMO

The continuous advancements in healthcare technology have empowered the discovery, diagnosis, and prediction of diseases, revolutionizing the field. Artificial intelligence (AI) is expected to play a pivotal role in achieving the goals of precision medicine, particularly in disease prevention, detection, and personalized treatment. This study aims to determine the optimal combination of the mother wavelet and AI model for the analysis of pediatric electroretinogram (ERG) signals. The dataset, consisting of signals and corresponding diagnoses, undergoes Continuous Wavelet Transform (CWT) using commonly used wavelets to obtain a time-frequency representation. Wavelet images were used for the training of five widely used deep learning models: VGG-11, ResNet-50, DensNet-121, ResNext-50, and Vision Transformer, to evaluate their accuracy in classifying healthy and unhealthy patients. The findings demonstrate that the combination of Ricker Wavelet and Vision Transformer consistently yields the highest median accuracy values for ERG analysis, as evidenced by the upper and lower quartile values. The median balanced accuracy of the obtained combination of the three considered types of ERG signals in the article are 0.83, 0.85, and 0.88. However, other wavelet types also achieved high accuracy levels, indicating the importance of carefully selecting the mother wavelet for accurate classification. The study provides valuable insights into the effectiveness of different combinations of wavelets and models in classifying ERG wavelet scalograms.


Assuntos
Inteligência Artificial , Análise de Ondaletas , Humanos , Criança , Eletrorretinografia
2.
Sensors (Basel) ; 23(21)2023 Oct 26.
Artigo em Inglês | MEDLINE | ID: mdl-37960427

RESUMO

The electroretinogram (ERG) is a clinical test that records the retina's electrical response to light. Analysis of the ERG signal offers a promising way to study different retinal diseases and disorders. Machine learning-based methods are expected to play a pivotal role in achieving the goals of retinal diagnostics and treatment control. This study aims to improve the classification accuracy of the previous work using the combination of three optimal mother wavelet functions. We apply Continuous Wavelet Transform (CWT) on a dataset of mixed pediatric and adult ERG signals and show the possibility of simultaneous analysis of the signals. The modern Visual Transformer-based architectures are tested on a time-frequency representation of the signals. The method provides 88% classification accuracy for Maximum 2.0 ERG, 85% for Scotopic 2.0, and 91% for Photopic 2.0 protocols, which on average improves the result by 7.6% compared to previous work.


Assuntos
Visão de Cores , Análise de Ondaletas , Adulto , Humanos , Criança , Eletrorretinografia/métodos , Retina/fisiologia , Aprendizado de Máquina
3.
J Ophthalmol ; 2024: 1990419, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39045382

RESUMO

Visual electrophysiology is often used clinically to determine the functional changes associated with retinal or neurological conditions. The full-field flash electroretinogram (ERG) assesses the global contribution of the outer and inner retinal layers initiated by the rods and cone pathways depending on the state of retinal adaptation. Within clinical centers, reference normative data are used to compare clinical cases that may be rare or underpowered within a specific demographic. To bolster either the reference dataset or the case dataset, the application of synthetic ERG waveforms may offer benefits to disease classification and case-control studies. In this study and as a proof of concept, artificial intelligence (AI) to generate synthetic signals using generative adversarial networks is deployed to upscale male participants within an ISCEV reference dataset containing 68 participants, with waveforms from the right and left eye. Random forest classifiers further improved classification for sex within the group from a balanced accuracy of 0.72-0.83 with the added synthetic male waveforms. This is the first study to demonstrate the generation of synthetic ERG waveforms to improve machine learning classification modelling with electroretinogram waveforms.

4.
Sci Data ; 11(1): 365, 2024 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-38605088

RESUMO

Optical coherence tomography (OCT) is a non-invasive imaging technique with extensive clinical applications in ophthalmology. OCT enables the visualization of the retinal layers, playing a vital role in the early detection and monitoring of retinal diseases. OCT uses the principle of light wave interference to create detailed images of the retinal microstructures, making it a valuable tool for diagnosing ocular conditions. This work presents an open-access OCT dataset (OCTDL) comprising over 2000 OCT images labeled according to disease group and retinal pathology. The dataset consists of OCT records of patients with Age-related Macular Degeneration (AMD), Diabetic Macular Edema (DME), Epiretinal Membrane (ERM), Retinal Artery Occlusion (RAO), Retinal Vein Occlusion (RVO), and Vitreomacular Interface Disease (VID). The images were acquired with an Optovue Avanti RTVue XR using raster scanning protocols with dynamic scan length and image resolution. Each retinal b-scan was acquired by centering on the fovea and interpreted and cataloged by an experienced retinal specialist. In this work, we applied Deep Learning classification techniques to this new open-access dataset.


Assuntos
Aprendizado Profundo , Retina , Doenças Retinianas , Tomografia de Coerência Óptica , Humanos , Retinopatia Diabética/diagnóstico por imagem , Edema Macular/diagnóstico por imagem , Retina/diagnóstico por imagem , Doenças Retinianas/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA