Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Clin Med ; 12(8)2023 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-37109303

RESUMO

OBJECTIVE: We aimed to test the non-inferiority of oral versus intravenous hydration in the incidence of contrast-associated acute kidney injury (CA-AKI) in elderly outpatients undergoing a contrast-enhanced computed tomography (CE-CT) scan. METHODS: PNIC-Na (NCT03476460) is a phase-2, single-center, randomized, open-label, non-inferiority trial. We included outpatients undergoing a CE-CT scan, >65 years having at least one risk factor for CA-AKI, such as diabetes, heart failure, or an estimated glomerular filtration rate (eGFR) of 30-59 mL/min/1.73 m². Participants were randomized (1:1) to oral sodium-chloride capsules or intravenous hydration. The primary outcome was an increase in serum creatinine >0.3 mg/dL or a reduction in eGFR >25% within 48 h. The non-inferiority margin was set at 5%. RESULTS: A total of 271 subjects (mean age 74 years, 66% male) were randomized, and 252 were considered for the main analysis (per-protocol). A total of 123 received oral hydration and 129 intravenous. CA-AKI occurred in 9 (3.6%) of 252 patients and 5/123 (4.1%) in the oral-hydration group vs. 4/129 (3.1%) in the intravenous-hydration group. The absolute difference between the groups was 1.0% (95% CI -4.8% to 7.0%), and the upper limit of the 95% CI exceeded the pre-established non-inferiority margin. No major safety concerns were observed. CONCLUSION: The incidence of CA-AKI was lower than expected. Although both regimens showed similar incidences of CA-AKI, the non-inferiority was not shown.

2.
Med Clin (Barc) ; 144(12): 550-2, 2015 Jun 22.
Artigo em Espanhol | MEDLINE | ID: mdl-25843634

RESUMO

BACKGROUND AND OBJECTIVE: Severe tricuspid regurgitation (TR) secondary to interference pacemaker (PM) cable is a rare cause of progressive right heart failure (HF), which can worsen patient outcomes. MATERIAL AND METHODS: We present 3 clinical cases of right HF secondary to TR after PM implantation. RESULTS: In these patients the clinic is right HF, which can appear early, as in our second patient, or after years of implementation of the PM, as in the first and third patients. The diagnosis is confirmed by echocardiography, the most accurate 3D, followed by transesophageal. The 2D transthoracic can not detect it, because it has low sensitivity for TR associated with PM. Medical treatment is always the first choice, since any other procedure carries significant morbidity and mortality. CONCLUSIONS: Probably this is a condition that we will diagnose with increasing frequency, because there are more and more patients with devices and, at the same time, the diagnostic tools are improving.


Assuntos
Eletrodos Implantados/efeitos adversos , Insuficiência Cardíaca/etiologia , Marca-Passo Artificial/efeitos adversos , Complicações Pós-Operatórias/etiologia , Insuficiência da Valva Tricúspide/etiologia , Idoso , Idoso de 80 Anos ou mais , Anuloplastia da Valva Cardíaca , Remoção de Dispositivo , Ecocardiografia Transesofagiana , Fenômenos Eletromagnéticos , Evolução Fatal , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/tratamento farmacológico , Humanos , Masculino , Derrame Pleural/etiologia , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/tratamento farmacológico , Sensibilidade e Especificidade , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/fisiopatologia , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA