Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Radiother Oncol ; 158: 276-284, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33636230

RESUMO

BACKGROUND AND PURPOSE: To quantify intra-fraction tumor motion using imageguidance and implanted fiducial markers to determine if a 5 mm planning-target-volume (PTV) margin is sufficient for early stage breast cancer patients receiving neoadjuvant stereotactic ablative radiotherapy (SABR). MATERIALS AND METHODS: A HydroMark© (Mammotome) fiducial was implanted at the time of biopsy adjacent to the tumor. Sixty-one patients with 62 tumours were treated prone using a 5 mm PTV margin. Motion was quantified using two methods (separate patient groups): 1) difference in 3D fiducial position pre- and post-treatment cone-beam CTs (CBCTs) in 18 patients receiving 21 Gy/1fraction (fx); 2) acquiring 2D triggered-kVimages to quantify 3D intra-fraction motion using a 2D-to-3D estimation method for 44 tumours receiving 21 Gy/1fx (n = 22) or 30 Gy/3fx (n = 22). For 2), motion was quantified by calculating the magnitude of intra-fraction positional deviation from the pretreatment CBCT. PTV margins were derived using van Herkian analysis. RESULTS: The average ± standard deviation magnitude of motion across patients was 1.3 ± 1.15 mm Left/Right (L/R), 1.0 ± 0.9 mm Inferiorly/Superiorly (I/S), and 1.8 ± 1.5 mm Anteriorly/Posteriorly (A/P). 85/105 (81%) treatment fractions had dominant anterior motion. 6/62patients (9.7%) had mean intra-fraction motion during any fraction > 5 mm in any direction, with 4 in the anterior direction. Estimated PTV margins for single and three-fx patients in the L/R, I/S, and A/P directions were 6.0x4.1x5.9 mm and 4.5x2.9x4.3 mm, respectively. CONCLUSION: Our results suggest that a 5 mm PTV margin is sufficient for the I/S and A/P directions if a lateral kV image is acquired immediately before treatment. For the L/R direction, either further immobilization or a larger margin is required.


Assuntos
Neoplasias da Mama , Radiocirurgia , Radioterapia Guiada por Imagem , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/radioterapia , Neoplasias da Mama/cirurgia , Tomografia Computadorizada de Feixe Cônico , Marcadores Fiduciais , Humanos , Terapia Neoadjuvante , Planejamento da Radioterapia Assistida por Computador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA