Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Micromachines (Basel) ; 14(5)2023 May 19.
Artigo em Inglês | MEDLINE | ID: mdl-37241700

RESUMO

Loop-mediated isothermal amplification (LAMP) is a rapid and high-yield amplification technology for specific DNA or RNA molecules. In this study, we designed a digital loop-mediated isothermal amplification (digital-LAMP)-functioning microfluidic chip to achieve higher sensitivity for detection of nucleic acids. The chip could generate droplets and collect them, based on which we could perform Digital-LAMP. The reaction only took 40 min at a constant temperature of 63 °C. The chip enabled highly accurate quantitative detection, with the limit of detection (LOD) down to 102 copies µL-1. For better performance while reducing the investment of money and time in chip structure iterations, we used COMSOL Multiphysics to simulate different droplet generation ways by including flow-focusing structure and T-junction structure. Moreover, the linear structure, serpentine structure, and spiral structure in the microfluidic chip were compared to study the fluid velocity and pressure distribution. The simulations provided a basis for chip structure design while facilitating chip structure optimization. The digital-LAMP-functioning chip proposed in the work provides a universal platform for analysis of viruses.

2.
Microsyst Nanoeng ; 9: 118, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37767528

RESUMO

To minimize and control the transmission of infectious diseases, a sensitive, accurate, rapid, and robust assay strategy for application on-site screening is critical. Here, we report single-molecule RNA capture-assisted digital RT-LAMP (SCADL) for point-of-care testing of infectious diseases. Target RNA was captured and enriched by specific capture probes and oligonucleotide probes conjugated to magnetic beads, replacing laborious RNA extraction. Droplet generation, amplification, and the recording of results are all integrated on a microfluidic chip. In assaying commercial standard samples, quantitative results precisely corresponded to the actual concentration of samples. This method provides a limit of detection of 10 copies mL-1 for the N gene within 1 h, greatly reducing the need for skilled personnel and precision instruments. The ultrasensitivity, specificity, portability, rapidity and user-friendliness make SCADL a competitive candidate for the on-site screening of infectious diseases.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA