Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 382
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Eur Heart J ; 2024 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-38820201

RESUMO

BACKGROUND AND AIMS: Surgical explantation of transcatheter heart valves (THVs) is rapidly increasing, but there are limited data on patients with THV-associated infective endocarditis (IE). This study aims to assess the outcomes of patients undergoing THV explant for IE. METHODS: All patients who underwent THV explant between 2011 and 2022 from 44 sites in the EXPLANT-TAVR registry were identified. Patients with IE as the reason for THV explant were compared to those with other mechanisms of bioprosthetic valve dysfunction (BVD). RESULTS: A total of 372 patients from the EXPLANT-TAVR registry were included. Among them, 184 (49.5%) patients underwent THV explant due to IE and 188 (50.5%) patients due to BVD. At the index transcatheter aortic valve replacement, patients undergoing THV explant for IE were older (74.3 ± 8.6 vs. 71 ± 10.6 years) and had a lower Society of Thoracic Surgeons risk score [2.6% (1.8-5.0) vs. 3.3% (2.1-5.6), P = .029] compared to patients with BVD. Compared to BVD, IE patients had longer intensive care unit and hospital stays (P < .05) and higher stroke rates at 30 days (8.6% vs. 2.9%, P = .032) and 1 year (16.2% vs. 5.2%, P = .010). Adjusted in-hospital, 30-day, and 1-year mortality was 12.1%, 16.1%, and 33.8%, respectively, for the entire cohort, with no significant differences between groups. Although mortality was numerically higher in IE patients 3 years postsurgery (29.6% for BVD vs. 43.9% for IE), Kaplan-Meier analysis showed no significant differences between groups (P = .16). CONCLUSIONS: In the EXPLANT-TAVR registry, patients undergoing THV explant for IE had higher 30-day and 1-year stroke rates and longer intensive care unit and hospital stays. Moreover, patients undergoing THV explant for IE had a higher 3-year mortality rate, which did not reach statistical significance given the relatively small sample size of this unique cohort and the reduced number of events.

2.
Catheter Cardiovasc Interv ; 103(1): 160-168, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38059295

RESUMO

BACKGROUND: New vascular closure devices (VCD) are being introduced for achieving hemostasis after transcatheter aortic valve implantation (TAVI). However, no safety or efficacy data have been published compared to other contemporary VCD. AIM: To compare the safety and efficacy of suture-based Perclose Prostyle as compared to plug-based MANTA device. METHODS: A total of 408 consecutive TAVI patients from two high volume TAVI centers were included in the present study. Patients were grouped according to VCD: Prostyle versus MANTA. Propensity score matching (PSM) and multivariable analysis were utilized to compare clinical endpoints between the two groups. The primary endpoint was any vascular complication (VC) according to VARC-3 criteria. RESULTS: After PSM, a total of 264 patients were analyzed, of them 132 in each group. Overall baseline characteristics of the two groups were comparable. Primary end-point was similar between MANTA as compared to Prostyle (16.7% vs. 15.3% respectively, p = 0.888). The main driver for VC among MANTA group were minor vascular complications (15.2%). Conversely, minor and major VC contributed equally to the primary endpoint among Prostyle group (7.6%) (p = 0.013). No outcome predictors were identified in multivariate analysis. CONCLUSIONS: VCD for transfemoral TAVI using the new-generation Prostyle device or the MANTA device achieved comparable VARC-3 VC rates.


Assuntos
Estenose da Valva Aórtica , Cateterismo Periférico , Substituição da Valva Aórtica Transcateter , Dispositivos de Oclusão Vascular , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/cirurgia , Cateterismo Periférico/efeitos adversos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Técnicas Hemostáticas/efeitos adversos
3.
Cardiol Young ; : 1-9, 2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38567959

RESUMO

OBJECTIVES: Atrioventricular valve regurgitation in patients with univentricular heart is a well-known risk factor for adverse outcomes and atrioventricular valve repair remains a particular surgical challenge. METHODS: We reviewed all surgical atrioventricular valve procedures in patients with univentricular heart and two separate atrioventricular valves who underwent surgical palliation. Endpoints of the study were reoperation-free survival and cumulative incidence of reoperation. RESULTS: Between 1994 and 2021, 202 patients with univentricular heart and two separate atrioventricular valve morphology underwent surgical palliation, with 15.8% (32/202) requiring atrioventricular valve surgery. Primary diagnoses were double inlet left ventricle (n = 14, 43.8%), double outlet right ventricle (n = 7, 21.9%), and congenitally corrected transposition of the great arteries (n = 7, 21.9%). Median weight at valve surgery was 10.6 kg (interquartile range, 7.9-18.9). Isolated left or right atrioventricular valve surgery was required in nine (28.1%) and 22 patients (68.8%), respectively. Concomitant left and right atrioventricular valve surgery was performed in one patient (3.1%). Closure of the left valve was conducted in four patients (12.5%) and closure of the right valve in three (9.4%). Operative and late mortality were 3.1% and 9.7%, respectively. Reoperation-free survival and cumulative incidence of reoperation at 10 years after surgery were 62.3% (standard error of the mean: 6.9) and 30.9% (standard error of the mean: 9.6), respectively. CONCLUSIONS: In patients with univentricular heart and two separate atrioventricular valves, surgical intervention on these valves is required in a minority of patients and is associated with low mortality but high incidence of reoperation.

4.
Mamm Genome ; 34(2): 285-297, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36867212

RESUMO

Systemic-to-pulmonary shunt malfunction contributes to morbidity in children with complex congenital heart disease after palliative procedure. Neointimal hyperplasia might play a role in the pathogenesis increasing risk for shunt obstruction. The aim was to evaluate the role of epidermal growth factor receptor (EGFR) and matrix-metalloproteinase 9 (MMP-9) in the formation of neointimal within shunts. Immunohistochemistry was performed with anti-EGFR and anti-MMP-9 on shunts removed at follow-up palliative or corrective procedure. Whole-genome single-nucleotide polymorphisms genotyping was performed on DNA extracted from patients´ blood samples and allele frequencies were compared between the group of patients with shunts displaying severe stenosis (≥ 40% of lumen) and the remaining group. Immunohistochemistry detected EGFR and MMP-9 in 24 of 31 shunts, located mainly in the luminal area. Cross-sectional area of EGFR and MMP-9 measured in median 0.19 mm2 (IQR 0.1-0.3 mm2) and 0.04 mm2 (IQR 0.03-0.09 mm2), respectively, and correlated positively with the area of neointimal measured on histology (r = 0.729, p < 0.001 and r = 0.0479, p = 0.018, respectively). There was a trend of inverse correlation between the dose of acetylsalicylic acid and the degree of EGFR, but not MMP-9, expression within neointima. Certain alleles in epidermal growth factor (EGF) and tissue inhibitor of metalloproteinases 1 (TIMP-1) were associated with increased stenosis and neointimal hyperplasia within shunts. EGFR and MMP-9 contribute to neointimal proliferation in SP shunts of children with complex cyanotic heart disease. SP shunts from patients carrying certain risk alleles in the genes encoding for EGF and TIMP-1 displayed increased neointima.


Assuntos
Cardiopatias , Neointima , Humanos , Criança , Neointima/patologia , Inibidor Tecidual de Metaloproteinase-1/genética , Inibidor Tecidual de Metaloproteinase-1/metabolismo , Hiperplasia/genética , Fator de Crescimento Epidérmico , Constrição Patológica , Receptores ErbB/genética
5.
Thorac Cardiovasc Surg ; 71(8): 632-640, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-35255516

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) for a degenerated surgical bioprosthesis (valve-in-valve [ViV]) has become an established procedure. Elevated gradients and patient-prosthesis mismatch (PPM) have previously been reported in mixed TAVR cohorts. We analyzed our single-center experience using the third-generation self-expanding Medtronic Evolut R prosthesis, with an emphasis on the incidence and outcomes of PPM. METHODS: This is a retrospective analysis of prospectively collected data from our TAVR database. Intraprocedural and intrahospital outcomes are reported. RESULTS: Eighty-six patients underwent ViV-TAVR with the Evolut R prosthesis. Mean age was 75.5 ± 9.5 years, 64% were males. The mean log EuroScore was 21.6 ± 15.7%. The mean time between initial surgical valve implantation and ViV-TAVR was 8.8 ± 3.2 years. The mean true internal diameter of the implanted surgical valves was 20.9 ± 2.2 mm. Post-AVR, 60% had no PPM, 34% had moderate PPM, and 6% had severe PPM. After ViV-TAVR, 33% had no PPM, 29% had moderate, and 39% had severe PPM. After implantation, the mean transvalvular gradient was reduced significantly from 36.4 ± 15.2 to 15.5 ± 9.1 mm Hg (p < 0.001). No patient had more than mild aortic regurgitation after ViV-TAVR. No conversion to surgery was necessary. Estimated Kaplan-Meier survival at 1 year for all patients was 87.4%. One-year survival showed no significant difference according to post-ViV PPM groups (p = 0.356). CONCLUSION: ViV-TAVR using a supra-annular valve resulted in low procedural and in-hospital complication rates. However, moderate or severe PPM was common, with no influence on short-term survival. PPM may not be a suitable factor to predict survival after ViV-TAVR.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Masculino , Humanos , Idoso , Idoso de 80 Anos ou mais , Feminino , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estudos Retrospectivos , Incidência , Desenho de Prótese , Resultado do Tratamento
6.
Thorac Cardiovasc Surg ; 71(5): 387-397, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-35644134

RESUMO

BACKGROUND: The advent of transcatheter aortic valve replacement (AVR) has led to an increased emphasis on reducing the invasiveness of surgical procedures. The aim of this study was to evaluate clinical outcomes and hemodynamic performance achieved with minimally invasive aortic valve replacement (MI-AVR) as compared with conventional AVR. METHODS: Patients who underwent surgical AVR with the Avalus bioprosthesis, as part of a prospective multicenter non-randomized trial, were included in this analysis. Surgical approach was left to the discretion of the surgeons. Patient characteristics and clinical outcomes were compared between MI-AVR and conventional AVR groups in the entire cohort (n = 1077) and in an isolated AVR subcohort (n = 528). Propensity score adjustment was performed to estimate the effect of MI-AVR on adverse events. RESULTS: Patients treated with MI-AVR were younger, had lower STS scores, and underwent concomitant procedures less often. Valve size implanted was comparable between the groups. MI-AVR was associated with longer procedural times in the isolated AVR subcohort. Postprocedural hemodynamic performance was comparable. There were no significant differences between MI-AVR and conventional AVR in early and 3-year all-cause mortality, thromboembolism, reintervention, or a composite of those endpoints within either the entire cohort or the isolated AVR subcohort. After propensity score adjustment, there remained no association between MI-AVR and the composite endpoint (hazard ratio: 0.86, 95% confidence interval: 0.47-1.55, p = 0.61). CONCLUSION: Three-year outcomes after MI-AVR with the Avalus bioprosthetic valve were comparable to conventional AVR. These results provide important insights into the overall ability to reduce the invasiveness of AVR without compromising outcomes.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estudos Prospectivos , Resultado do Tratamento , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Hemodinâmica , Estudos Retrospectivos
7.
Circulation ; 144(17): 1409-1428, 2021 10 26.
Artigo em Inglês | MEDLINE | ID: mdl-34694888

RESUMO

BACKGROUND: Complex molecular programs in specific cell lineages govern human heart development. Hypoplastic left heart syndrome (HLHS) is the most common and severe manifestation within the spectrum of left ventricular outflow tract obstruction defects occurring in association with ventricular hypoplasia. The pathogenesis of HLHS is unknown, but hemodynamic disturbances are assumed to play a prominent role. METHODS: To identify perturbations in gene programs controlling ventricular muscle lineage development in HLHS, we performed whole-exome sequencing of 87 HLHS parent-offspring trios, nuclear transcriptomics of cardiomyocytes from ventricles of 4 patients with HLHS and 15 controls at different stages of heart development, single cell RNA sequencing, and 3D modeling in induced pluripotent stem cells from 3 patients with HLHS and 3 controls. RESULTS: Gene set enrichment and protein network analyses of damaging de novo mutations and dysregulated genes from ventricles of patients with HLHS suggested alterations in specific gene programs and cellular processes critical during fetal ventricular cardiogenesis, including cell cycle and cardiomyocyte maturation. Single-cell and 3D modeling with induced pluripotent stem cells demonstrated intrinsic defects in the cell cycle/unfolded protein response/autophagy hub resulting in disrupted differentiation of early cardiac progenitor lineages leading to defective cardiomyocyte subtype differentiation/maturation in HLHS. Premature cell cycle exit of ventricular cardiomyocytes from patients with HLHS prevented normal tissue responses to developmental signals for growth, leading to multinucleation/polyploidy, accumulation of DNA damage, and exacerbated apoptosis, all potential drivers of left ventricular hypoplasia in absence of hemodynamic cues. CONCLUSIONS: Our results highlight that despite genetic heterogeneity in HLHS, many mutations converge on sequential cellular processes primarily driving cardiac myogenesis, suggesting novel therapeutic approaches.


Assuntos
Síndrome do Coração Esquerdo Hipoplásico/genética , Organogênese/genética , Heterogeneidade Genética , Humanos
8.
Basic Res Cardiol ; 117(1): 11, 2022 03 08.
Artigo em Inglês | MEDLINE | ID: mdl-35258704

RESUMO

Cardiosphere-derived cells (CDCs) generated from human cardiac biopsies have been shown to have disease-modifying bioactivity in clinical trials. Paradoxically, CDCs' cellular origin in the heart remains elusive. We studied the molecular identity of CDCs using single-cell RNA sequencing (sc-RNAseq) in comparison to cardiac non-myocyte and non-hematopoietic cells (cardiac fibroblasts/CFs, smooth muscle cells/SMCs and endothelial cells/ECs). We identified CDCs as a distinct and mitochondria-rich cell type that shared biological similarities with non-myocyte cells but not with cardiac progenitor cells derived from human-induced pluripotent stem cells. CXCL6 emerged as a new specific marker for CDCs. By analysis of sc-RNAseq data from human right atrial biopsies in comparison with CDCs we uncovered transcriptomic similarities between CDCs and CFs. By direct comparison of infant and adult CDC sc-RNAseq data, infant CDCs revealed GO-terms associated with cardiac development. To analyze the beneficial effects of CDCs (pro-angiogenic, anti-fibrotic, anti-apoptotic), we performed functional in vitro assays with CDC-derived extracellular vesicles (EVs). CDC EVs augmented in vitro angiogenesis and did not stimulate scarring. They also reduced the expression of pro-apoptotic Bax in NRCMs. In conclusion, CDCs were disclosed as mitochondria-rich cells with unique properties but also with similarities to right atrial CFs. CDCs displayed highly proliferative, secretory and immunomodulatory properties, characteristics that can also be found in activated or inflammatory cell types. By special culture conditions, CDCs earn some bioactivities, including angiogenic potential, which might modify disease in certain disorders.


Assuntos
Células Endoteliais , Adulto , Humanos , Miócitos Cardíacos , Análise de Sequência de RNA , Células-Tronco
9.
Thorac Cardiovasc Surg ; 70(3): 199-204, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-33761568

RESUMO

BACKGROUND: Third-generation transcatheter heart valves (THV) are predominantly implanted through a percutaneous, transfemoral access. To reduce vascular complications, we selectively performed surgical vascular access (cutdown) in patients with particular calcified or small femoral arteries. We aim to review our experience with this approach. METHODS: All patients who underwent transfemoral transcatheter aortic valve replacement (TAVR) with a third-generation THV at our institution between March 2014 and April 2019 were included in the study. All available computerized tomography studies were reassessed for access vessel diameter and visual graduation of calcifications. Vascular complications are reported according to Valve Academic Research Consortium-2 criteria. RESULTS: A total of 944 patients were included. Among them, 879 patients underwent a percutaneous access and 65 patients underwent surgical cutdown. Also, 459 Evolut R/PRO and 420 Sapien 3/ultra were implanted percutaneously and 40 Evolut R/PRO and 25 Sapien 3 were implanted with a surgical cutdown. Patients with surgical cutdown were older (80.0 ± 7.5 vs. 83.8 ± 7.5 years, p < 0.001), had smaller femoral arteries (8.0 ± 1.6 vs. 7.6 ± 1.6 mm, p = 0.034) and more severe vessel calcifications (17.5 vs. 1.0%, p < 0.001). Procedure time was similar for cutdown and percutaneous access (64.0 vs. 64.5 minutes, p = 0.879). With percutaneous access, 80 major vascular complications (10%) occurred, whereas with surgical cutdown, no major vascular complications occurred (p < 0.005). No wound infection occurred after surgical cutdown. The mean length of stay was 8 days in both groups. CONCLUSION: Surgical cutdown for vascular access avoids vascular complications in patients with small or severely calcified femoral arteries.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/etiologia , Estenose da Valva Aórtica/cirurgia , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/cirurgia , Humanos , Estudos Retrospectivos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
10.
Artigo em Inglês | MEDLINE | ID: mdl-36462752

RESUMO

BACKGROUND: We aimed to compare hemodynamic performance of the Avalus (Medtronic) and the Perimount Magna Ease (PME, Edwards Lifesciences) bioprosthesis up to 5 years by serial echocardiographic examinations. METHODS: In patients undergoing aortic valve replacement, 58 received PME prostheses between October 2007 and October 2008, and another 60 received Avalus prostheses between October 2014 and November 2015. To ensure similar baseline characteristics, we performed a propensity score matching based on left ventricular ejection fraction, age, body surface area, and aortic annulus diameter measured by intraoperative transesophageal echocardiography. Thereafter, 48 patients remained in each group. Mean age at operation was 67 ± 6 years and mean EuroSCORE-II was 1.7 ± 1.1. Both values did not differ significantly between the two groups. RESULTS: At 1 year the mean pressure gradient (MPG) was 15.4 ± 4.3 mm Hg in the PME group and 14.7 ± 5.1 mm Hg in the Avalus group (p = 0.32). The effective orifice area (EOA) was 1.65 ± 0.45 cm2 in the PME group and 1.62 ± 0.45 cm2 in the Avalus group (p = 0.79). At 5 years the MPG was 16.6 ± 5.1 mm Hg in the PME group and 14.7 ± 7.1 mm Hg in the Avalus group (p = 0.20). The EOA was 1.60 ± 0.49 cm2 in the PME group and 1.51 ± 0.40 cm2 in the Avalus group (p = 0.38). Five-year survival was 88% in the PME group and 91% in the Avalus group (p = 0.5). In the PME group, there were no reoperations on the aortic valve, whereas in the Avalus group three patients required a reoperation due to endocarditis. CONCLUSION: Both bioprostheses exhibit similar hemodynamic performance during a 5-year follow-up.

11.
J Card Surg ; 37(10): 3110-3116, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35870166

RESUMO

INTRODUCTION: Aortic valve neocuspidization (AVNeo) for trileaflet aortic valve reconstruction using autologous pericardium (Ozaki procedure) depicts an encouraging new technique for the surgical treatment of aortic valve pathologies. The current study analyzes the early hemodynamic outcome of AVneo compared with surgical aortic valve replacement (SAVR) using the Abbott/St. Jude Trifecta aortic valve biological prostheses. METHODS: All patients who underwent either AVNeo or SAVR between March 2017 and April 2020 were included. Exclusion criteria were emergency cases, endocarditis, redo- or additional root procedures. Main endpoints were differences between the two groups in terms of the effective orifice area (EOA) and the effective orifice area index (EOAI) at discharge. RESULTS: During the study period, 105 AVNeo patients and 458 SAVR patients met the inclusion criteria. EOA was significantly higher in the AVNeo group (2.4 cm2 ± 0.8 vs. 2.1 cm2 /m2 ± 0.6 in the SAVR group, respectively; p < .001). Multiple regression analysis, including AVNeo, annulus size, bicuspid valve, preoperative stenosis, left ventricular ejection fraction (LVEF), and diastolic diameter (LVEDD) found two factors, which favor larger EOA: Annulus size (p < .0001) and AVneo (p = .005). EOAI was significantly higher in the AVNeo group (1.23 ± 0.4 vs. 1.02 cm2 /m2 ± 0.3, respectively; p < .001). Multiple regression analysis for EOAI showed effects for AVneo (p = .005) and bicuspid valve (p = .029). Mean pressure gradients (MPG) were lower in the AVNeo group than in the SAVR group (AVNeo: MPG = 8.0 mmHg ± 3.6 vs. SAVR: MPG = 8.3 mmHg ± 3.6), but this finding did not reach statistical significance (p = .091). CONCLUSIONS: AVNeo shows significantly larger EOA and EOAI compared to SAVR using the Abbott/St. Jude Trifecta aortic valve biological prostheses.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Pericárdio/transplante , Desenho de Prótese , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
12.
J Card Surg ; 37(10): 2999-3005, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35790024

RESUMO

BACKGROUND: Isolated tricuspid valve endocarditis (TVE) is a rare disease which is managed medically in most patients. Only in specific cases, surgical intervention becomes necessary. Hence, data about surgical outcomes are sparse. This study reports on the operative experience in patients with isolated TVE over a period of 20 years. METHODS: We retrospectively analyzed 32 patients with isolated TVE who underwent surgery from February 2001 to June 2021 at the German Heart Centre Munich. RESULTS: Thirty-day mortality was 3.1%. Overall survival was 89.9± 5.5% at 1 year and 76.9 ± 8.5% at 5 years. Cumulative incidence for reoperation was 11.1 ± 6.0% at 5 years. Four patients (12.5%) were treated for recurrent endocarditis. Tricuspid valve repair (TVr) was achieved in 16 patients (50%). If the subvalvular apparatus (n = 10) was involved, tricuspid valve replacement was performed more frequently. CONCLUSIONS: Mortality in patients with isolated TVE undergoing cardiac surgery is high. In half of the cases, TVr was achieved but was less likely in patients with affected subvalvular apparatus.


Assuntos
Endocardite , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Endocardite/cirurgia , Humanos , Estudos Retrospectivos , Resultado do Tratamento , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/cirurgia
13.
J Card Surg ; 37(12): 4999-5010, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36378942

RESUMO

INTRODUCTION: The Carpentier-Edwards PERIMOUNT Magna Ease valve is a third-generation bioprosthesis for aortic valve replacement (AVR). This is a postapproval study reporting on its 8-year outcomes. METHODS: Adults undergoing AVR with the Magna Ease valve between October 2007 and December 2012 were enrolled for this prospective, nonrandomized, single-arm, and multicenter study. Assessments occurred preoperatively, at hospital discharge, 6 months, 1 year, and annually thereafter for up to 8 years. Outcomes included safety endpoints, hemodynamic performance, and New York Heart Association (NYHA) functional class. RESULTS: Of the 258 study patients, 67.5% were in NYHA Class I or II, and 32.5% were in NYHA Class III or IV at baseline. Concomitant procedures were performed in 44.2%. Total follow-up was 1597.6 patient-years, and median follow-up was 7 years (interquartile range: 5.5-8.0 years). Eight years following AVR, the functional class remained improved from baseline with 93.9% in NYHA Class I/II and 6.1% in NYHA Class III; 38 deaths had occurred, 8 of which were valve related; freedom from all-cause mortality was 80.7% (95% confidence intervals: 74.9, 86.4); freedom from valve-related mortality was 95.8% (92.8, 98.8); freedom from reintervention, explant, major bleeding events, and structural valve deterioration was 89.8% (85.1, 94.6), 94.8% (91.7, 97.9), 85.1% (80.0, 90.1), and 90.1% (84.7, 95.4), respectively; effective orifice area was 1.5 ± 0.5 cm2 , the mean gradient was 14.8 ± 8.3 mmHg, and 88.6% of patients had no or trivial aortic regurgitation. CONCLUSIONS: This study demonstrated satisfactory safety and sustained hemodynamic and functional improvements at 8 years following AVR with the Magna Ease valve.


Assuntos
Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Adulto , Humanos , Valva Aórtica/cirurgia , Estudos Prospectivos , Desenho de Prótese , Seguimentos , Estudos Retrospectivos
14.
Clin Oral Investig ; 26(7): 4977-4985, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35316412

RESUMO

OBJECTIVES: It has been reported that bacteria associated with infective endocarditis originate from the oral cavity in 26-45% of cases. However, little is known on the counts and species of periodontal microbiota in infected heart valves. The aim of this study was to identify these aspects of periodontal microbiota in infective endocarditis and to potentially initiate a dental extraction concept for periodontally compromised teeth concerning patients requiring heart valve surgery. MATERIALS AND METHODS: The retrospective study group consisted of tissue samples from infected heart valves of 683 patients who had undergone heart valve surgery. Before patients had undergone cardiac surgery, the following laboratory tests confirmed the occurrence of endocarditis in all patients: blood cultures, echocardiography, electrocardiography, chest X-ray, and electrophoresis of the serum proteins. The specimens were aseptically obtained and deep frozen immediately following surgery. Microbiological diagnosis included proof of germs (dichotomous), species of germs, and source of germs (oral versus other). RESULTS: Microbiota was detected in 134 (31.2%) out of 430 enrolled patients. Oral cavity was supposed to be the source in 10.4% of cases, whereas microbiota of the skin (57.5%) and gastrointestinal tract (GIT, 24.6%) were detected considerably more frequently. Moreover, periodontal bacteria belonged mostly to the Streptococci species and the yellow complex. None of the detected bacteria belonged to the red complex. CONCLUSION: Most frequently, the skin and GIT represented the site of origin of the microbiota. Nevertheless, the oral cavity represented the source of IE in up to 10%. Consequently, it needs to be emphasized that a good level of oral hygiene is strongly recommended in all patients undergoing heart valve surgery in order to reduce the bacterial load in the oral cavity, thereby minimizing the hematogenous spread of oral microbiota. The prerequisites for conservative dental treatment versus radical tooth extraction must always be based on the patient's cooperation, and the clinical intraoral status on a sense of proportion in view of the overall clinical situation due to the underlying cardiac disease. CLINICAL RELEVANCE: The oral cavity is a source of oral microbiota on infected heart valves. Patients requiring heart valve surgery should always undergo a critical evaluation of dental treatment affecting periodontally compromised teeth, favoring a systematic, conservative-leaning recall.


Assuntos
Endocardite Bacteriana , Endocardite , Microbiota , Bactérias , Endocardite Bacteriana/diagnóstico , Endocardite Bacteriana/microbiologia , Endocardite Bacteriana/cirurgia , Humanos , Estudos Retrospectivos
15.
Z Gerontol Geriatr ; 55(5): 421-430, 2022 Aug.
Artigo em Alemão | MEDLINE | ID: mdl-35748931

RESUMO

Atypical Parkinson syndromes represent a neuropathologically heterogeneous group and include the clinical entities dementia with Lewy bodies (DLB), multiple system atrophy (MSA), progressive supranuclear palsy (PSP), and corticobasal degeneration (CBD). The DLB and MSA are characterized by deposition of the protein alpha-synuclein (synucleinopathy), PSP and CBD are characterized by deposition of tau protein, often in the form of neurofibrillary tangles in nerve and glial cells (tauopathy). Misfolding and aggregation of the aforementioned proteins causes degeneration of the affected cell populations but the disease also spreads to anatomically neighboring brain regions, thus contributing to disease progression. The clinical characteristics (poor response to dopaminergic treatment, ataxia, apraxia, vertical gaze palsy and rapid progression) enable a differentiation from idiopathic Parkinson's disease.


Assuntos
Atrofia de Múltiplos Sistemas , Doença de Parkinson , Paralisia Supranuclear Progressiva , Encéfalo/metabolismo , Humanos , Atrofia de Múltiplos Sistemas/diagnóstico , Atrofia de Múltiplos Sistemas/metabolismo , Atrofia de Múltiplos Sistemas/terapia , Doença de Parkinson/diagnóstico , Paralisia Supranuclear Progressiva/diagnóstico , Paralisia Supranuclear Progressiva/metabolismo
16.
J Card Surg ; 36(12): 4537-4545, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34580919

RESUMO

BACKGROUND: The dual-filter Sentinel™ Cerebral Protection System (Sentinel-CPS) is increasingly used during transcatheter aortic valve replacement (TAVR). However, complex vascular anatomy may challenge Sentinel-CPS deployment. AIM OF THE STUDY: We sought to investigate the impact of anatomic features of the aortic arch and the supra-aortic arteries on technical device failure of Sentinel-CPS application. METHODS: Analysis of the multislice computed tomography pre-TAVR aortograms of all patients undergoing TAVR with Sentinel-CPS between 2016 and 2020 (n = 92) was performed. We investigated the impact of aortic arch anatomy, configuration, and the angles of the supra-aortic arteries, including the determination of vascular tortuosity index on device failure of Sentinel-CPS application. RESULTS: The Sentinel-CPS was applied successfully in 83 patients (90.2%). Device failure in nine patients (9.8%) was due to the infeasibility to perform correct deployment of both filters (n = 7) and to obtain peripheral radial access (n = 2). Patients with a failure of Sentinel-CPS application had a higher right subclavian tortuosity index (217 [92-324] vs. 150 [42-252], p = .046), a higher brachiocephalic tortuosity index (27 [5-51] vs. 10 [0-102], p = 0.033) and a larger angulation of the brachiocephalic artery (59° [22-80] vs. 39° [7-104], p = .014) compared with patients with successful application. A brachiocephalic angle more than 59° was predictive for device failure. No differences in aortic arch anatomy or common carotid artery tortuosity were detected between the groups. CONCLUSIONS: Brachiocephalic tortuosity was found to be associated with failure of Sentinel-CPS application. Filter-based usage should be avoided in TAVR patients with a brachiocephalic angle more than 59°.


Assuntos
Estenose da Valva Aórtica , Dispositivos de Proteção Embólica , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Humanos , Tomografia Computadorizada Multidetectores , Desenho de Prótese , Fatores de Risco , Resultado do Tratamento
17.
N Engl J Med ; 376(14): 1321-1331, 2017 04 06.
Artigo em Inglês | MEDLINE | ID: mdl-28304219

RESUMO

BACKGROUND: Although transcatheter aortic-valve replacement (TAVR) is an accepted alternative to surgery in patients with severe aortic stenosis who are at high surgical risk, less is known about comparative outcomes among patients with aortic stenosis who are at intermediate surgical risk. METHODS: We evaluated the clinical outcomes in intermediate-risk patients with severe, symptomatic aortic stenosis in a randomized trial comparing TAVR (performed with the use of a self-expanding prosthesis) with surgical aortic-valve replacement. The primary end point was a composite of death from any cause or disabling stroke at 24 months in patients undergoing attempted aortic-valve replacement. We used Bayesian analytical methods (with a margin of 0.07) to evaluate the noninferiority of TAVR as compared with surgical valve replacement. RESULTS: A total of 1746 patients underwent randomization at 87 centers. Of these patients, 1660 underwent an attempted TAVR or surgical procedure. The mean (±SD) age of the patients was 79.8±6.2 years, and all were at intermediate risk for surgery (Society of Thoracic Surgeons Predicted Risk of Mortality, 4.5±1.6%). At 24 months, the estimated incidence of the primary end point was 12.6% in the TAVR group and 14.0% in the surgery group (95% credible interval [Bayesian analysis] for difference, -5.2 to 2.3%; posterior probability of noninferiority, >0.999). Surgery was associated with higher rates of acute kidney injury, atrial fibrillation, and transfusion requirements, whereas TAVR had higher rates of residual aortic regurgitation and need for pacemaker implantation. TAVR resulted in lower mean gradients and larger aortic-valve areas than surgery. Structural valve deterioration at 24 months did not occur in either group. CONCLUSIONS: TAVR was a noninferior alternative to surgery in patients with severe aortic stenosis at intermediate surgical risk, with a different pattern of adverse events associated with each procedure. (Funded by Medtronic; SURTAVI ClinicalTrials.gov number, NCT01586910 .).


Assuntos
Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/mortalidade , Teorema de Bayes , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Masculino , Complicações Pós-Operatórias , Fatores de Risco , Índice de Gravidade de Doença , Acidente Vascular Cerebral/epidemiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos
18.
Catheter Cardiovasc Interv ; 95(4): 859-862, 2020 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-31794136

RESUMO

Transcatheter heart valve implantation into degenerated bioprosthetic valves (ViV-THV implantation) has become an established procedure for high risk patients. In general, paravalvular leak (PVL) is a contraindication for valve-in-valve-TAVR (ViV-TAVR). Herein, we report on a 81-year-old patient presenting with acute heart failure for a failing aortic bioprosthesis (Medtronic Mosaic 27 mm). Intraoperative transesophageal echocardiography during urgent ViV-TAVR revealed a PVL previously not detected. After transfemoral implantation of a 26 mm-Evolut-R, balloon-fracturing of the bioprosthetic ring was performed using a 24 mm True Dilatation balloon for treatment of the PVL. Afterward, left ventricular to aortic peak-to-peak pressure gradient measured 2-4mmHg. Transesophageal echocardiography merely revealed trace PVL. Aortic root angiography showed no PVL. At discharge, echocardiography measured a transprosthetic mean gradient of 5mmHg detecting no PVL. Intentional ring-fracturing of an aortic valve prostheses may prove not only to be effective in lowering transvalvular gradients after valve-in-valve-TAVR, but may also be a tool to treat PVL alongside degenerated surgical aortic bioprostheses in certain patients.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Bioprótese , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Falha de Prótese , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/fisiopatologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Hemodinâmica , Humanos , Masculino , Desenho de Prótese , Recuperação de Função Fisiológica , Resultado do Tratamento
19.
Thorac Cardiovasc Surg ; 68(7): 616-622, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-31091551

RESUMO

BACKGROUND: There is a growing use of cerebral protection devices in patients undergoing transcatheter aortic valve replacement (TAVR). We aimed to analyze if the use of these devices itself has an impact on the complexity and the risk of TAVR. METHODS: Between February 2016 and July 2017, 391 patients underwent transfemoral TAVR with Medtronic CoreValve Evolut R (n = 196) or Edwards Sapien 3 (n = 195). In 39 patients, the Claret Sentinel™ embolic protection device (CS-EPD) was used. Prospectively collected data were retrospectively analyzed, comparing fluoroscopy/operation time, amount of contrast used, vascular events, and postprocedural renal function in TAVR patients with (n = 39) and without (n = 352) CS-EPD. RESULTS: The CS-EPD was placed through the right radial (n = 35) or brachial (n = 4) artery. Procedural success rate defined as correct deployment and retraction of both filters was 94.9%. No device-related vascular complications occurred. TAVR patients with CS-EPD showed a significantly higher total operation time, total fluoroscopy time, and amount of used contrast (85.4 ± 39.3 vs. 64 ± 29.8 minutes, p = 0.002; 20.7 ± 9.3 vs. 13.7 ± 7 minutes, p ≤ 0.001; 133.7 ± 42.6 vs. 109.7 ± 44.5 mL, p = 0.001). Comparing the initial third of patients receiving a CS-EPD with the last third of CS-EPD cases, procedural time had decreased significantly (102.5 ± 34.9 vs. 67 ± 11.9; p = 0.002). There were no differences in postprocedural renal failure (p = 0.80). CONCLUSION: Our data add evidence that the application of the CS-EPD is not associated with an additional risk for the patient. Although procedural time and amount of contrast are still higher when using the CS-EPD, there were no device-related complications or increased incidence of renal failure.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Dispositivos de Proteção Embólica , Próteses Valvulares Cardíacas , Embolia Intracraniana/prevenção & controle , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Feminino , Hemodinâmica , Humanos , Embolia Intracraniana/etiologia , Masculino , Duração da Cirurgia , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
20.
J Card Surg ; 35(12): 3617-3619, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33001483

RESUMO

BACKGROUND: Despite advances in surgical techniques, aortic reoperation is still associated with a high risk of mortality due to possible injury of the myocardium or great vessels during resternotomy. MATERIALS & METHODS: We report the case of a giant aortic pseudoaneurysm, 17 years after the Bentall procedure in a 76-year-old male patient. RESULTS: Successful pseudoaneurysm resection after the Bentall procedure using the ThruPort IntraClude intra-aortic occlusion device (Edwards Lifesciences) was achieved. DISCUSSION: The IntraClude catheter can be used effectively to provide endovascular clamping of the ascending aorta during challenging cardiac reoperations.


Assuntos
Falso Aneurisma , Idoso , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/etiologia , Falso Aneurisma/cirurgia , Aorta/cirurgia , Humanos , Masculino , Complicações Pós-Operatórias/cirurgia , Reoperação , Procedimentos Cirúrgicos Vasculares
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA