RESUMO
OBJECTIVE: We defined reference ranges for maternal cardiac output, systemic vascular resistance, and stroke volume measured in the third trimester of pregnancy using the Ultrasound Cardiac Output Monitor 1A. DESIGN: Based on data from the prospective PEACH (PreEclampsia, Angiogenesis, Cardiac dysfunction and Hypertension) cohort study. SETTING: Rigshospitalet and Hvidovre Hospital, Denmark. SAMPLE: Normotensive pregnant women aged 18-45 years with singleton pregnancies, enrolled in the PEACH study in 2016-2018. METHODS: We modelled cardiac output, systemic vascular resistance and stroke volume as a function of gestational age using multilevel linear models with fractional polynomials. MAIN OUTCOME MEASURES: Unconditional and conditional reference ranges for cardiovascular parameters measured in gestational weeks 28-40. RESULTS: Our study cohort included 405 healthy pregnant women who contributed 1210 cardiovascular function measurements for analysis. Maximum cardiac output and stroke volume values were measured in gestational weeks 30-32 and decreased over the third trimester, whereas systemic vascular resistance increased during the same period. We created reference ranges for eight combinations of maternal height, age and parity. We also created a simple calculator to allow for implementation of the reference ranges in clinical practice. CONCLUSIONS: Our reference ranges allow the use of a bedside ultrasound device to non-invasively assess cardiac function in pregnancy and identify women at risk of complications. The unconditional ranges allow clinicians to evaluate isolated measurements and identify women needing follow-up. The conditional ranges incorporate information from previous measurements and improve monitoring over time.
Assuntos
Gestantes , Feminino , Gravidez , Humanos , Terceiro Trimestre da Gravidez , Estudos de Coortes , Estudos Prospectivos , Valores de Referência , Débito CardíacoRESUMO
BACKGROUND: Whether cardiovascular dysfunction is associated with preeclampsia in women without fetal growth restriction (FGR) is unclear. Our objective was to investigate associations between third-trimester cardiac output (CO) and systemic vascular resistance and risk of hypertensive disorders of pregnancy in women with and without FGR. METHODS AND RESULTS: A case-cohort study in 906 pregnant women in Denmark with repeated third-trimester cardiac function assessments was performed using the Ultrasound Cardiac Output Monitor 1A. Using Cox regression, we compared rates of hypertensive disorders of pregnancy in women with low, normal, and high CO and normal and high systemic vascular resistance, by FGR status and gestational age, and evaluated associations between a third-trimester drop in CO or increase in systemic vascular resistance and preeclampsia risk in women without FGR. The analysis included 249 women with preeclampsia (42 with FGR) and 119 women with gestational hypertension. Low CO was strongly associated with preeclampsia at <37 weeks (women with FGR: hazard ratio [HR], 5.25 [95% CI, 1.26-21.9]; women without FGR: HR, 2.19 [95% CI, 1.07-4.48]). Our results also suggested an association between low CO and preeclampsia at ≥37 weeks among women without FGR (HR, 1.31 [95% CI, 0.84-2.03]), and between a third-trimester drop in CO >75th percentile and preeclampsia in women without FGR (odds ratio, 1.91 [95% CI, 0.84-4.36]). High systemic vascular resistance was strongly associated with increased rates of all forms of hypertensive disorders of pregnancy. CONCLUSIONS: Low CO is associated with preeclampsia risk in women with and without FGR, particularly before 37 weeks. Repeated measurements of third-trimester cardiovascular function might identify women without FGR for monitoring for preeclampsia, but this result needs to be confirmed in other studies.