Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 181
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Eur Heart J ; 45(10): 778-790, 2024 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-38231881

RESUMO

BACKGROUND AND AIMS: Both clonal haematopoiesis of indeterminate potential (CHIP) and atrial fibrillation (AF) are age-related conditions. This study investigated the potential role of CHIP in the development and progression of AF. METHODS: Deep-targeted sequencing of 24 CHIP mutations (a mean depth of coverage = 1000×) was performed in 1004 patients with AF and 3341 non-AF healthy subjects. Variant allele fraction ≥ 2.0% indicated the presence of CHIP mutations. The association between CHIP and AF was evaluated by the comparison of (i) the prevalence of CHIP mutations between AF and non-AF subjects and (ii) clinical characteristics discriminated by CHIP mutations within AF patients. Furthermore, the risk of clinical outcomes-the composite of heart failure, ischaemic stroke, or death-according to the presence of CHIP mutations in AF was investigated from the UK Biobank cohort. RESULTS: The mean age was 67.6 ± 6.9 vs. 58.5 ± 6.5 years in AF (paroxysmal, 39.0%; persistent, 61.0%) and non-AF cohorts, respectively. CHIP mutations with a variant allele fraction of ≥2.0% were found in 237 (23.6%) AF patients (DNMT3A, 13.5%; TET2, 6.6%; and ASXL1, 1.5%) and were more prevalent than non-AF subjects [356 (10.7%); P < .001] across the age. After multivariable adjustment (age, sex, smoking, body mass index, diabetes, and hypertension), CHIP mutations were 1.4-fold higher in AF [adjusted odds ratio (OR) 1.38; 95% confidence interval 1.10-1.74, P < .01]. The ORs of CHIP mutations were the highest in the long-standing persistent AF (adjusted OR 1.50; 95% confidence interval 1.14-1.99, P = .004) followed by persistent (adjusted OR 1.44) and paroxysmal (adjusted OR 1.33) AF. In gene-specific analyses, TET2 somatic mutation presented the highest association with AF (adjusted OR 1.65; 95% confidence interval 1.05-2.60, P = .030). AF patients with CHIP mutations were older and had a higher prevalence of diabetes, a longer AF duration, a higher E/E', and a more severely enlarged left atrium than those without CHIP mutations (all P < .05). In UK Biobank analysis of 21 286 AF subjects (1297 with CHIP and 19 989 without CHIP), the CHIP mutation in AF is associated with a 1.32-fold higher risk of a composite clinical event (heart failure, ischaemic stroke, or death). CONCLUSIONS: CHIP mutations, primarily DNMT3A or TET2, are more prevalent in patients with AF than non-AF subjects whilst their presence is associated with a more progressive nature of AF and unfavourable clinical outcomes.


Assuntos
Fibrilação Atrial , Isquemia Encefálica , Diabetes Mellitus , Insuficiência Cardíaca , AVC Isquêmico , Acidente Vascular Cerebral , Idoso , Humanos , Pessoa de Meia-Idade , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/genética , Fibrilação Atrial/complicações , Isquemia Encefálica/complicações , Hematopoiese Clonal/genética , Estudos de Coortes , População do Leste Asiático , Insuficiência Cardíaca/complicações , AVC Isquêmico/complicações , Acidente Vascular Cerebral/epidemiologia
2.
Clin Gastroenterol Hepatol ; 22(5): 981-993.e11, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38184099

RESUMO

BACKGROUND & AIMS: In patients with atrial fibrillation (AF) receiving direct oral anticoagulant (DOAC), upper gastrointestinal bleeding (UGIB) is a serious complication. There are limited data on the benefit of preventive proton pump inhibitor (PPI) use to reduce the risk of UGIB in DOAC users. METHODS: We included patients with AF receiving DOAC from 2015 to 2020 based on the Korean Health Insurance Review and Assessment database. The propensity score (PS) weighting method was used to compare patients with PPI use and those without PPI use. The primary outcome was hospitalization for UGIB. Weighted hazard ratios (HRs) and corresponding 95% confidence intervals (CIs) were evaluated using the Cox proportional hazards regression model. RESULTS: A total of 165,624 patients were included (mean age: 72.2 ± 10.8 years; mean CHA2DS2-VASc score: 4.3 ± 1.8; mean HAS-BLED score: 3.3 ± 1.2). Among them, 99,868 and 65,756 were in the non-PPI group and PPI group, respectively. During a median follow-up of 1.5 years, the PPI group was associated with lower risks of hospitalization for UGIB and UGIB requiring red blood cell transfusion than non-PPI group (weighted HR, 0.825; 95% CI, 0.761-0.894 and 0.798; 95% CI, 0.717-0.887, respectively, both P < .001). The benefits of PPI on the risk of hospitalization for UGIB were greater in those with older age (≥75 years), higher HAS-BLED score (≥3), prior GIB history, and concomitant use of antiplatelet agent (all P-for-interaction < .1). Low-dose PPI was consistently associated with a lower risk of significant UGIB by 43.6-49.3% (P < .001). CONCLUSIONS: In this large Asian cohort of patients with AF on DOAC, PPI co-therapy is beneficial for reducing the risk of hospitalization for UGIB, particularly in high-risk patients.


Assuntos
Fibrilação Atrial , Hemorragia Gastrointestinal , Inibidores da Bomba de Prótons , Humanos , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/complicações , Inibidores da Bomba de Prótons/administração & dosagem , Inibidores da Bomba de Prótons/uso terapêutico , Inibidores da Bomba de Prótons/efeitos adversos , Masculino , Feminino , Idoso , Hemorragia Gastrointestinal/induzido quimicamente , Hemorragia Gastrointestinal/epidemiologia , Hemorragia Gastrointestinal/prevenção & controle , República da Coreia , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Anticoagulantes/efeitos adversos , Anticoagulantes/administração & dosagem , Anticoagulantes/uso terapêutico , Hospitalização/estatística & dados numéricos , Estudos de Coortes , Administração Oral , Estudos Retrospectivos
3.
J Cardiovasc Electrophysiol ; 35(1): 69-77, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37927151

RESUMO

INTRODUCTION: Influence of early atrial fibrillation (AF) ablation, particularly cryoballoon ablation (CBA), on clinical outcome during long-term follow-up has not been clarified. The objective was to determine whether an early CBA (diagnosis-to-ablation of ≤6 months) strategy could affect freedom from AF recurrence after index CBA. METHODS: The study included 2605 patients from Korean CBA registry data with follow-up >12 months after de novo CBA. The primary outcome was recurrence of atrial tachyarrhythmias (ATs) of ≥30-s after a 3-month blanking period. RESULTS: Compared to patients in early CBA group, patients in late CBA group had higher prevalence of diabetes, congestive heart failure, and chronic kidney disease, and higher mean CHA2 DS2 -VAS score. During mean follow-up of >21 months, ATs recurrence was detected in 839 (32.2%) patients. The early CBA group showed a significantly lower 2-year recurrence rate of ATs than the late CBA group (26.1% vs. 31.7%, p = 0.043). In subgroup analysis, the early CBA group showed significantly higher 1-year and 2-year freedom from ATs recurrence than the late CBA group only in paroxysmal atrial fibrillation (PAF) patients in overall and propensity score matched cohorts. Multivariate analysis showed that early CBA was an independent factor for preventing ATs recurrence in PAF (hazard ratio: 0.637; 95% confidence intervals: 0.412-0.984). CONCLUSION: Early CBA strategy, resulting in significantly lower ATs recurrence during 2-year follow-up after index CBA, might be considered as an initial rhythm control therapy in patients with paroxysmal AF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Átrios do Coração , República da Coreia/epidemiologia , Resultado do Tratamento , Ablação por Cateter/efeitos adversos , Recidiva , Veias Pulmonares/cirurgia
4.
Artigo em Inglês | MEDLINE | ID: mdl-38890808

RESUMO

INTRODUCTION: The impact of early recurrence of atrial tachyarrhythmia (ERAT) within the 90-day blanking period on long-term outcomes in atrial fibrillation (AF) patients undergoing cryoballoon ablation (CBA) is controversial. This study aimed to assess the relationship between ERAT and late recurrence of atrial tachyarrhythmia (LRAT) post-CBA. METHODS: Utilizing data from a multicenter registry in Korea (May 2018 to June 2022), we analyzed the presence and timing of ERAT (<30, 30-60, and 60-90 days) and its association with LRAT risk after CBA. LRAT was defined as any recurrence of AF, atrial flutter, or atrial tachycardia lasting more than 30 s beyond the 90 days. RESULTS: Out of 2636 patients, 745 (28.2%) experienced ERAT post-CBA. Over an average follow-up period of 21.2 ± 10.3 months, LRAT was observed in 874 (33.1%) patients. Patients with ERAT had significantly lower 1-year LRAT freedom compared to those without ERAT (42.6% vs. 85.5%, p < .001). Multivariate analysis identified ERAT as a potential predictor of LRAT, with a hazard ratio (HR) of 3.98 (95% confidence interval [CI], 3.47-4.57). Significant associations were noted across all examined time frames (HR, 3.84; 95% CI, 3.32-4.45 in <30 days, HR, 5.53; 95% CI, 4.13-7.42 in 30-60 days, and HR, 4.29; 95% CI, 3.12-5.89 in 60-90 days). This finding was consistently observed across all types of AF. CONCLUSION: ERAT during the 90-day blanking period strongly predicts LRAT in AF patients undergoing CBA, indicating a need to reconsider the clinical significance of this period.

5.
Cardiovasc Diabetol ; 23(1): 115, 2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38555442

RESUMO

BACKGROUND: Diabetes mellitus (DM) duration affects incident atrial fibrillation (AF) risk; the effect of physical activity on mitigating AF risk related to varying DM duration remains unknown. We assessed the effect of physical activity on incident AF in patients with DM with respect to known DM duration. METHODS: Patients with type 2 DM who underwent the Korean National Health Insurance Service health examination in 2015-2016 were grouped by DM duration: new onset and < 5, 5-9, and ≥ 10 years. Physical activity was classified into four levels: 0, < 500, 500-999, 1,000-1,499, and ≥ 1,500 metabolic equivalent task (MET)-min/week, with the primary outcome being new-onset AF. RESULTS: The study enrolled 2,392,486 patients (aged 59.3 ± 12.0 years, 39.8% female) with an average follow-up of 3.9 ± 0.8 years and mean DM duration of 5.3 ± 5.1 years. Greater physical activity was associated with a lower AF risk. Lowering of incident AF risk varied with different amounts of physical activity in relation to known DM duration. Among patients with new-onset DM, DM duration < 5 years and 5-9 years and 1,000-1,499 MET-min/week exhibited the lowest AF risk. Physical activity ≥ 1,500 MET-min/week was associated with the lowest incident AF risk in patients with DM duration ≥ 10 years (by 15%), followed DM duration of 5-9 years (12%) and < 5 years (9%) (p-for-interaction = 0.002). CONCLUSIONS: Longer DM duration was associated with a high risk of incident AF, while increased physical activity generally reduced AF risk. Engaging in > 1,500 MET-min/week was associated with the greatest AF risk reduction in patients with longer DM duration, highlighting the potential benefits of higher activity levels for AF prevention.


Assuntos
Fibrilação Atrial , Diabetes Mellitus Tipo 2 , Humanos , Feminino , Masculino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/prevenção & controle , Fatores de Risco , Incidência , Diabetes Mellitus Tipo 2/diagnóstico , Diabetes Mellitus Tipo 2/epidemiologia , Diabetes Mellitus Tipo 2/complicações , Exercício Físico
6.
Europace ; 26(2)2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38290433

RESUMO

AIMS: Data on the optimal use of antithrombotic drugs and associated clinical outcomes in patients with atrial fibrillation (AF) and acute ischaemic stroke (IS) are limited. We investigated the prescription patterns of antithrombotics in community practice and long-term clinical prognosis according to early post-stroke antithrombotic therapy in patients with AF and acute IS. METHODS AND RESULTS: Patients with AF who were admitted for acute IS at a single tertiary hospital in 2010-2020 were retrospectively reviewed. Clinical profiles including the aetiology of stroke and prescription patterns of antithrombotics were identified. The net clinical outcome (NCO)-the composite of recurrent stroke, any bleeding, hospitalization or emergency department visits for cardiovascular (CV) events, and death-was compared according to the antithrombotic therapy at the first outpatient clinic visit [oral anticoagulation (OAC) alone vs. antiplatelet (APT) alone vs. OAC/APT(s)] following discharge. A total of 918 patients with AF and acute IS (mean age, 72.6 years; male, 59.3%; mean CHA2DS2-VASc score 3.3) were analysed. One-third (33.9%, n = 310) of patients were simultaneously diagnosed with AF and IS. The most common aetiology of IS was cardioembolism (71.2%), followed by undetermined aetiology (19.8%) and large artery atherosclerosis (6.0%). OAC, APT(s), and concomitant OAC and APT(s) were prescribed in 33.4%, 11.1%, and 53.4% of patients during admission that changed to 67.0%, 9.1%, and 21.7% at the first outpatient clinic, and were mostly continued up to one year after IS. Non-prescription of OAC was observed in 11.3% of post-stroke patients with AF. During a median follow-up of 2.1 years, the overall incidence rate of NCO per 100 patient-year (PY) was 20.14. APT(s) monotherapy presented the highest cumulative risk of NCO (adjusted hazard ratio 1.47, 95% confidence interval 1.08-2.00, P = 0.015; with reference to OAC monotherapy) mainly driven by the highest rates of recurrent stroke and any bleeding. OAC/APT(s) combination therapy was associated with a 1.62-fold significantly higher risk of recurrent stroke (P = 0.040) and marginally higher risk of any bleeding than OAC monotherapy. CONCLUSION: Approximately one-third of acute IS in AF have a distinctive mechanism from cardioembolism. Although APT was frequently prescribed in post-stroke patients with AF, no additive clinical benefit was observed. Adherence to OAC treatment is essential to prevent further CV adverse events in patients with AF and IS.


Assuntos
Fibrilação Atrial , Isquemia Encefálica , AVC Isquêmico , Acidente Vascular Cerebral , Humanos , Masculino , Idoso , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/epidemiologia , Fibrinolíticos/efeitos adversos , Anticoagulantes/efeitos adversos , Inibidores da Agregação Plaquetária/efeitos adversos , Estudos Retrospectivos , Fatores de Risco , Hemorragia/induzido quimicamente , Estudos de Coortes , Resultado do Tratamento , Administração Oral
7.
Europace ; 26(5)2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38624037

RESUMO

AIMS: Pulmonary vein isolation using cryoablation is effective and safe in patients with atrial fibrillation (AF). Although both obesity and underweight are associated with a higher risk for incident AF, there is limited data on the efficacy and safety following cryoablation according to body mass index (BMI) especially in Asians. METHODS AND RESULTS: Using the Korean Heart Rhythm Society Cryoablation registry, a multicentre registry of 12 tertiary hospitals, we analysed AF recurrence and procedure-related complications after cryoablation by BMI (kg/m2) groups (BMI < 18.5, underweight, UW; 18.5-23, normal, NW; 23-25, overweight, OW; 25-30, obese Ⅰ, OⅠ; ≥30, obese Ⅱ, OⅡ). A total of 2648 patients were included (median age 62.0 years; 76.7% men; 55.6% non-paroxysmal AF). Patients were categorized by BMI groups: 0.9% UW, 18.7% NW, 24.8% OW, 46.1% OI, and 9.4% OII. Underweight patients were the oldest and had least percentage of non-paroxysmal AF (33.3%). During a median follow-up of 1.7 years, atrial arrhythmia recurred in 874 (33.0%) patients (incidence rate, 18.9 per 100 person-years). After multivariable adjustment, the risk of AF recurrence was higher in UW group compared with NW group (adjusted hazard ratio, 95% confidence interval; 2.55, 1.18-5.50, P = 0.02). Procedure-related complications occurred in 123 (4.7%) patients, and the risk was higher for UW patients (odds ratio, 95% confidence interval; 2.90, 0.94-8.99, P = 0.07), mainly due to transient phrenic nerve palsy. CONCLUSION: Underweight patients showed a higher risk of AF recurrence after cryoablation compared with NW patients. Also, careful attention is needed on the occurrence of phrenic nerve palsy in UW patients.


Assuntos
Fibrilação Atrial , Índice de Massa Corporal , Criocirurgia , Obesidade , Veias Pulmonares , Recidiva , Sistema de Registros , Humanos , Fibrilação Atrial/cirurgia , Criocirurgia/efeitos adversos , Masculino , Feminino , Pessoa de Meia-Idade , República da Coreia/epidemiologia , Idoso , Resultado do Tratamento , Fatores de Risco , Veias Pulmonares/cirurgia , Obesidade/complicações , Magreza/complicações , Fatores de Tempo , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia
8.
Br J Sports Med ; 58(8): 427-434, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38418213

RESUMO

OBJECTIVE: Data on cardiovascular outcomes according to objectively measured physical activity (PA) in patients with atrial fibrillation (AF) are scarce. This study explored the associations between PA derived from wrist-worn accelerometers and the risk of death, incident heart failure (HF), and incident stroke in patients with AF. METHODS: From 37 990 patients with AF in UK Biobank, 2324 patients with accelerometer data were included. Weekly moderate-to-vigorous PA (MVPA) duration was computed from accelerometer data. The primary outcome was all-cause mortality. Secondary outcomes were cardiovascular mortality, incident HF, and incident stroke. Restricted cubic splines estimated the dose-response associations between MVPA duration and the outcomes. The adjusted HRs (aHRs) of the outcomes according to adherence to PA standard guidelines (performing MVPA≥150 min/week) were also evaluated. RESULTS: The mean age was 66.9±6.2 years and 64.9% were male. During a median follow-up of 6.7 years, there were 181 all-cause deaths, 62 cardiovascular deaths, 225 cases of incident HF, and 91 cases of incident stroke; the overall incidence rate per 1000 patient-years was 11.76, 4.03, 15.16 and 5.99, respectively. There was a linear inverse dose-response relationship between MVPA (≥108 min/week) and all-cause mortality. Performing MVPA for 105-590 min/week was associated with a lower risk of HF than those with no measurable MVPA. The risk of stroke and cardiovascular mortality was not associated with MVPA. Performing guideline-adherent MVPA was related to a 30% lower risk of all-cause mortality (aHR: 0.70 (0.50-0.98), p=0.04) and 33% lower risk of HF (aHR 0.67 (0.49-0.93), p=0.02). CONCLUSION: In patients with AF, accelerometer-derived PA data supports lower risks of all-cause mortality and HF according to a greater level of MVPA and adherence to PA guidelines. Regular MVPA should be encouraged in patients with AF as a part of integrated management.


Assuntos
Fibrilação Atrial , Insuficiência Cardíaca , Acidente Vascular Cerebral , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Fibrilação Atrial/epidemiologia , Estudos Prospectivos , Biobanco do Reino Unido , Bancos de Espécimes Biológicos , Exercício Físico/fisiologia , Acelerometria
9.
J Med Internet Res ; 26: e46098, 2024 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-38512332

RESUMO

BACKGROUND: Wearable electrocardiogram (ECG) monitoring devices are used worldwide. However, data on the diagnostic yield of an adhesive single-lead ECG patch (SEP) to detect premature ventricular complex (PVC) and the optimal duration of wearing an SEP for PVC burden assessment are limited. OBJECTIVE: We aimed to validate the diagnostic yield of an SEP (mobiCARE MC-100, Seers Technology) for PVC detection and evaluate the PVC burden variation recorded by the SEP over a 3-day monitoring period. METHODS: This is a prospective study of patients with documented PVC on a 12-lead ECG. Patients underwent simultaneous ECG monitoring with the 24-hour Holter monitor and SEP on the first day. On the subsequent second and third days, ECG monitoring was continued using only SEP, and a 3-day extended monitoring was completed. The diagnostic yield of SEP for PVC detection was evaluated by comparison with the results obtained on the first day of Holter monitoring. The PVC burden monitored by SEP for 3 days was used to assess the daily and 6-hour PVC burden variations. The number of patients additionally identified to reach PVC thresholds of 10%, 15%, and 20% during the 3-day extended monitoring by SEP and the clinical factors associated with the higher PVC burden variations were explored. RESULTS: The recruited data of 134 monitored patients (mean age, 54.6 years; males, 45/134, 33.6%) were analyzed. The median daily PVC burden of these patients was 2.4% (IQR 0.2%-10.9%), as measured by the Holter monitor, and 3.3% (IQR 0.3%-11.7%), as measured in the 3-day monitoring by SEP. The daily PVC burden detected on the first day of SEP was in agreement with that of the Holter monitor: the mean difference was -0.07%, with 95% limits of agreement of -1.44% to 1.30%. A higher PVC burden on the first day was correlated with a higher daily (R2=0.34) and 6-hour burden variation (R2=0.48). Three-day monitoring by SEP identified 29% (12/42), 18% (10/56), and 7% (4/60) more patients reaching 10%, 15%, and 20% of daily PVC burden, respectively. Younger age was additionally associated with the identification of clinically significant PVC burden during the extended monitoring period (P=.02). CONCLUSIONS: We found that the mobiCARE MC-100 SEP accurately detects PVC with comparable diagnostic yield to the 24-hour Holter monitor. Performing 3-day PVC monitoring with SEP, especially among younger patients, may offer a pragmatic alternative for identifying more individuals exceeding the clinically significant PVC burden threshold.


Assuntos
Complexos Ventriculares Prematuros , Masculino , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos , Complexos Ventriculares Prematuros/diagnóstico , Eletrocardiografia , Eletrocardiografia Ambulatorial , Tecnologia
11.
BMC Med ; 21(1): 509, 2023 12 21.
Artigo em Inglês | MEDLINE | ID: mdl-38129845

RESUMO

BACKGROUND: The predictive relationship between mild-to-moderate alcohol consumption and the risk of incident atrial fibrillation (AF) remains controversial. OBJECTIVE: We investigated whether the relationship between alcohol consumption and the risk of incident AF could be associated with the genetic predisposition to alcohol metabolism. METHODS: A total of 399,329 subjects with genetic data from the UK Biobank database, enrolled between 2006 and 2010, were identified and followed for incident AF until 2021. Genetic predisposition to alcohol metabolism was stratified according to the polygenic risk score (PRS) tertiles. Alcohol consumption was categorized as non-drinkers, mild-to-moderate drinkers (< 30 g/day), and heavy drinkers (≥ 30 g/day). RESULTS: During the follow-up (median 12.2 years), 19,237 cases of AF occurred. When stratified by PRS tertiles, there was a significant relationship between genetic predisposition to alcohol metabolism and actual alcohol consumption habits (P < 0.001). Mild-to-moderate drinkers showed a decreased risk of AF (HR 0.96, 95% CI 0.92-0.99), and heavy drinkers showed an increased risk of AF (HR 1.06, 95% CI 1.02-1.10) compared to non-drinkers. When stratified according to PRS tertiles for genetic predisposition to alcohol metabolism, mild-to-moderate drinkers had equivalent AF risks, and heavy drinkers showed increased AF risk in the low PRS tertile group. However, mild-to-moderate drinkers had decreased AF risks and heavy drinkers showed similar risks of AF in the middle/high PRS tertile groups. CONCLUSIONS: Differential associations between alcohol consumption habits and incident AF across genetic predisposition to alcohol metabolism were observed; individuals with genetic predisposition to low alcohol metabolism were more susceptible to AF.


Assuntos
Fibrilação Atrial , Humanos , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/genética , Estudos de Coortes , Fatores de Risco , Biobanco do Reino Unido , Bancos de Espécimes Biológicos , Consumo de Bebidas Alcoólicas/efeitos adversos , Consumo de Bebidas Alcoólicas/epidemiologia , Consumo de Bebidas Alcoólicas/genética , Predisposição Genética para Doença
12.
J Cardiovasc Electrophysiol ; 34(9): 1811-1819, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37595097

RESUMO

INTRODUCTION: Although left atrial wall thickness (LAWT) is known to be varied, a fixed target Ablation Index (AI) based pulmonary vein isolation (PVI) has been suggested in catheter ablation for atrial fibrillation (AF). We aimed to evaluate the efficacy and safety of PVI applying tailored AI based on LAWT assessed by cardiac computed tomography (CT). METHODS: The thick segment was defined as the segment including ≥LAWT grade 3 (≥1.5 mm). The fixed AI strategy was defined as AI targets were 450 on the anterior/roof segments and 350 on the posterior/inferior/carina segments regardless of LAWT. The tailored AI strategy consisted of AI increasing the targets to 500 on the anterior/roof segments and to 400 on the posterior/inferior/carina segments when ablating the thick segment. After PVI, acute pulmonary vein (PV) reconnection, defined by the composite of residual potential and early reconnection, was evaluated. RESULTS: A total of 156 patients (paroxysmal AF 72%) were consecutively included (86 for the fixed AI group and 70 for the tailored AI group). The tailored AI group showed a significantly lower rate of segments with acute PV reconnection than the fixed AI group (8% vs. 5%, p = .007). The tailored AI group showed a trend for shorter ablation time for PVI. One-year AF/atrial tachycardia free survival rate was similar in two groups (87.2% in the fixed AI group and 90.0% in the tailored AI group, p = .606). CONCLUSION: Applying tailored AI based on the LAWT was a feasible and effective strategy to reduce acute PV reconnection after PVI.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Tomografia Computadorizada por Raios X , Ablação por Cateter/efeitos adversos
13.
Cardiovasc Diabetol ; 22(1): 18, 2023 01 30.
Artigo em Inglês | MEDLINE | ID: mdl-36717853

RESUMO

BACKGROUND: Patients with concurrent atrial fibrillation (AF) and diabetes mellitus (DM) [AF-DM] have a high risk of cardiovascular and diabetes-related complications, but are less engaged in a comprehensive treatment approach. We evaluated the association of early rhythm control (ERC), lifestyle modification (LSM), and a combination of ERC and LSM with cardiovascular or diabetes-related complication risk in patients with AF-DM (type 2). METHODS: From the National Health Information Database, 47,940 patients diagnosed with AF-DM in 2009-2016 were included. We defined ERC as rhythm control therapy within two years of AF diagnosis and LSM as adherence to ≥ 2 of the healthy behaviors among non-current smoking, non-drinking, and regular exercise. We compared the primary (ischemic stroke) and secondary (macro- and microvascular complications, glycemic emergency, and all-cause death) outcomes in four groups: non-ERC and non-LSM (group 1), LSM only (group 2), ERC only (group 3), and both ERC and LSM (group 4). RESULTS: Of total, 10,617 (22%), 26,730 (55.8%), 2,903 (6.1%), and 7,690 (16.0%) were classified into groups 1 to 4, in sequence. The mean duration from AF diagnosis to ERC was 25.6 ± 75.5 days. During 4.0 (interquartile range: 2.5-6.2) years' follow-up, groups 2 and 3 were associated with 23% and 33% lower risks of stroke than group 1, respectively. Group 4 was associated with the lowest risk of stroke: hazard ratio (HR) 0.58, 95% confidence interval (CI) 0.51-0.67, p < 0.001. Regarding secondary outcomes, the lowest risks were also observed in group 4; macro- and microvascular complications, glycemic emergency, and all-cause death had HRs (95% CIs) of 0.63 (0.56-0.70), 0.88 (0.82-0.94), 0.72 (0.62-0.84), and 0.80 (0.73-0.87), respectively, all p < 0.001. CONCLUSIONS: For AF-DM patients, ERC and LSM exert a synergistic effect in preventing cardiovascular and diabetes-related complications with the greatest lowered risk of stroke. A comprehensive treatment approach should be pursued in AF-DM patients.


Assuntos
Fibrilação Atrial , Prestação Integrada de Cuidados de Saúde , Complicações do Diabetes , Diabetes Mellitus Tipo 2 , Diabetes Mellitus , Acidente Vascular Cerebral , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/terapia , Estudos de Coortes , Fatores de Risco , Prognóstico , Diabetes Mellitus Tipo 2/complicações , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/prevenção & controle , Complicações do Diabetes/diagnóstico , Complicações do Diabetes/epidemiologia , Complicações do Diabetes/terapia , Estilo de Vida Saudável , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/epidemiologia , Diabetes Mellitus/terapia
14.
Cardiovasc Diabetol ; 22(1): 12, 2023 01 19.
Artigo em Inglês | MEDLINE | ID: mdl-36658574

RESUMO

BACKGROUND: Patients with diabetes mellitus have an increased risk of incident atrial fibrillation (AF). The effect of accumulated hypertension burden is a less well-known modifiable risk factor. We explored the relationship between accumulated hypertension burden and incident AF in these patients. METHODS: We evaluated data for 526,384 patients with diabetes who underwent three consecutive health examinations, between 2009 and 2012, from the Korean National Health Insurance Service. Hypertension burden was calculated by assigning points to each stage of hypertension in each health examination: 1 for stage 1 hypertension (systolic blood pressure [SBP] 130-139 mmHg; diastolic blood pressure [DBP] 80-89 mmHg); 2 for stage 2 (SBP 140-159 mmHg and DBP 90-99 mmHg); and 3 for stage 3 (SBP ≥ 160 mmHg or DBP ≥ 100 mmHg). Patients were categorized into 10 hypertensive burden groups (0-9). Groups 1-9 were then clustered into 1-3, 4-6, and 7-9. RESULTS: During a mean follow-up duration of 6.7 ± 1.7 years, AF was newly diagnosed in 18,561 (3.5%) patients. Compared to patients with hypertension burden 0, those with burden 1 to 9 showed a progressively increasing risk of incident AF: 6%, 11%, 16%, 24%, 28%, 41%, 46%, 57%, and 67% respectively. Clusters 1-3, 4-6, and 7-9 showed increased risks by 10%, 26%, and 45%, respectively, when compared to a hypertension burden of 0. CONCLUSIONS: Accumulated hypertension burden was associated with an increased risk of incident AF in patients with diabetes. Strict BP control should be emphasized for these patients.


Assuntos
Fibrilação Atrial , Diabetes Mellitus , Hipertensão , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Hipertensão/diagnóstico , Hipertensão/epidemiologia , Hipertensão/complicações , Pressão Sanguínea , Fatores de Risco , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/epidemiologia
15.
BMC Cardiovasc Disord ; 23(1): 51, 2023 01 27.
Artigo em Inglês | MEDLINE | ID: mdl-36703129

RESUMO

BACKGROUND: Takotsubo syndrome (TTS) with physical triggers has worse short- and long-term clinical courses than those with emotional triggers. However, predictive factors associated with poor outcomes of TTS with physical triggers are unknown. METHODS: We included 231 patients identified as TTS preceded by physical triggers at two tertiary referral hospitals from 2010 to 2019. In-hospital complications (IHC)-a composite of malignant arrhythmia, need for mechanical circulatory support or mechanical ventilation, and in-hospital death-and overall mortality were retrospectively reviewed. The associations with clinical features were evaluated by multivariable logistic and Cox regression analyses. RESULTS: The mean age was 69.3 ± 11.6 years, and 85 (36.8%) were male. The in-hospital complications rate was 46.8%. During a median follow-up of 883 days, 96 (41.6%) had died, and overall mortality was 13.6% per patient-year. Higher neutrophil-to-lymphocyte ratio (NLR) was associated with a higher risk of IHC (area under the receiver operating characteristic curve = 0.73; positive and negative predictive value = 60.9% and 67.2% for NLR ≤ 12); odds ratio (OR) with 95% confidence interval (CI) was 1.03 (1.01-1.05), p = 0.010. Subsequently, higher NLR was also related to a greater risk of overall mortality; patients with high NLR (NLR > 12) exhibited poor long-term survival than those with low NLR (NLR ≤ 5): hazard ratio (95% CI), 3.70 (1.72-7.94) with p < 0.001. CONCLUSIONS: A high NLR at initial presentation is associated with an increased risk of IHC and overall mortality in TTS preceded by physical triggers. Given that the treatment of TTS is mainly supportive, intensive monitoring with careful follow-up would be warranted in patients with high NLR.


Assuntos
Neutrófilos , Cardiomiopatia de Takotsubo , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Feminino , Mortalidade Hospitalar , Cardiomiopatia de Takotsubo/diagnóstico , Cardiomiopatia de Takotsubo/terapia , Cardiomiopatia de Takotsubo/complicações , Estudos Retrospectivos , Linfócitos , Hospitais , Prognóstico
16.
J Korean Med Sci ; 38(24): e186, 2023 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-37337809

RESUMO

BACKGROUND: As an indicator of electro-mechanical coupling, electromechanical window (EMW) can be used to predict fatal ventricular arrhythmias. We investigated the additive effect of EMW on the prediction of fatal ventricular arrhythmias in high-risk patients. METHODS: We included patients who had implantable cardioverter-defibrillator (ICD) implanted for primary or secondary prevention. The event group was defined as those who received an appropriate ICD therapy. We acquired echocardiograms at ICD implantation and follow-up. The EMW was calculated as the difference between the interval from QRS onset to aortic valve closure and QT interval from the electrocardiogram embedded in the continuous wave doppler image. We evaluated the predictive value of EMW for predicting fatal ventricular arrhythmia. RESULTS: Of 245 patients (67.2 ± 12.8 years, 63.7% men), the event group was 20.0%. EMW at baseline (EMW-Baseline) and follow-up (EMW-FU) was significantly different between event and control groups. After adjustment, both EMW-Baseline (odds ratio [OR]adjust 1.02 [1.01-1.03], P = 0.004) and EMW-FU (ORadjust 1.06 [1.04-1.07], P < 0.001) remained as significant predictors for fatal arrhythmic events. Adding EMW-Baseline significantly improved the discriminating ability of the multivariable model including clinical variables (area under the curve [AUC] 0.77 [0.70-0.84] vs. AUC 0.72 [0.64-0.80], P = 0.004), while a univariable model using EMW-FU alone showed the best performance among models (AUC 0.87 [0.81-0.94], P = 0.060 against model with clinical variables; P = 0.030 against model with clinical variables and EMW-Baseline). CONCLUSION: The EMW could effectively predict severe ventricular arrhythmia in ICD implanted patients. This finding supports the importance of incorporating the electro-mechanical coupling index into the clinical practice for predicting future fatal arrhythmia events.


Assuntos
Arritmias Cardíacas , Desfibriladores Implantáveis , Masculino , Humanos , Feminino , Arritmias Cardíacas/diagnóstico , Eletrocardiografia , Ecocardiografia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Fatores de Risco
17.
Cardiovasc Diabetol ; 21(1): 251, 2022 11 17.
Artigo em Inglês | MEDLINE | ID: mdl-36397079

RESUMO

BACKGROUND: It is unclear whether mental disorders are an independent risk factor for atrial fibrillation (AF) in patients with diabetes. We aimed to investigate whether patients with diabetes who have mental disorders have an increased risk for AF. METHODS: Using the Korea National Health Insurance Service database, we enrolled 2,512,690 patients diagnosed with diabetes without AF between 2009 and 2012. We assessed five mental disorders: depression, insomnia, anxiety, bipolar disorder, and schizophrenia. Newly diagnosed AF was identified during the follow-up period, and multivariate Cox regression analysis was performed. RESULTS: Among the 2,512,690 patients (mean age 57.2 ± 12.3 years; 60.1% men), 828,929 (33.0%) had mental disorders. Among the five mental disorders, anxiety (68.1%) was the most common, followed by insomnia (40.0%). During a median follow-up duration of 7.1 years, new-onset AF was diagnosed in 79,525 patients (4.66 per 1,000 person-years). Patients with diabetes who had mental disorders showed a higher risk for AF (adjusted hazard ratio [HR] 1.19; 95% confidence interval [CI] 1.17-1.21; p-value < 0.001). Depression, insomnia, and anxiety were significantly associated with higher risk for AF (adjusted HR [95% CI]: 1.15 [1.12-1.17], 1.15 [1.13-1.18], and 1.19 [1.67-1.21], respectively; all p-values < 0.001), whereas bipolar disorder and schizophrenia were not. CONCLUSIONS: Mental disorders, especially depression, insomnia, and anxiety, were associated with an increased risk for AF in patients with diabetes. Greater awareness with a prompt diagnosis of AF should be considered for patients with both DM and mental disorders.


Assuntos
Fibrilação Atrial , Diabetes Mellitus , Transtornos Mentais , Distúrbios do Início e da Manutenção do Sono , Masculino , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Feminino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Distúrbios do Início e da Manutenção do Sono/complicações , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/epidemiologia , Transtornos Mentais/diagnóstico , Transtornos Mentais/epidemiologia , Transtornos Mentais/complicações , Fatores de Risco
18.
Br J Clin Pharmacol ; 88(11): 4676-4687, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35921204

RESUMO

AIMS: The evidence of a protective effect of proton-pump inhibitor (PPI) in oral anticoagulant (OAC)-treated patients against gastrointestinal bleeding (GIB) is still lacking. We conducted a meta-analysis to estimate the risk of GIB in patients with OAC and PPI cotherapy. METHODS: A systematic search of PubMed, EMBASE, Cochrane and Scopus databases was performed for studies reporting GIB risk in OAC and PPI cotherapy. Primary outcomes were total GIB and major GIB events. Pooled estimates of GIB risk were calculated by a random-effect meta-analysis and reported as odds ratios and 95% confidence interval. RESULTS: A total of 10 studies and 1 970 931 patients were included. OAC and PPI cotherapy were associated with a lower odds of total and major GIB; odds ratio (95% confidence interval) was 0.67 (0.62-0.74) for total and 0.68 (0.63-0.75) for major GIB, respectively. No differences in the GIB of PPI cotherapy were observed between Asians and non-Asians (P-for-difference, total GIB = .70, major GIB = .75, respectively). For all kinds of OAC except for edoxaban, PPI cotreatment was related to lower odds of GIB by 24-44%. The protective effect of PPI on total GIB was more significant in concurrent antiplatelets or nonsteroidal anti-inflammatory drug users and those with high bleeding risks: patients with previous GIB history, HAS-BLED ≥3 or underlying gastrointestinal diseases. CONCLUSION: In patients who receive OAC, PPI cotherapy is associated with a lower total and major GIB irrespective of ethnic group and OAC type, except for edoxaban. PPI cotherapy can be considered particularly in patients with high risk of GIB.


Assuntos
Anticoagulantes , Inibidores da Bomba de Prótons , Anti-Inflamatórios não Esteroides , Anticoagulantes/efeitos adversos , Hemorragia Gastrointestinal/induzido quimicamente , Hemorragia Gastrointestinal/epidemiologia , Hemorragia Gastrointestinal/prevenção & controle , Humanos , Inibidores da Bomba de Prótons/efeitos adversos , Piridinas , Tiazóis
19.
Cardiovasc Drugs Ther ; 36(4): 679-689, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-33730289

RESUMO

PURPOSE: The risk of gastrointestinal bleeding (GIB) can be mitigated by proton pump inhibitor (PPI) co-therapy in patients with atrial fibrillation (AF) treated with anticoagulants. We aimed to evaluate the effect of PPIs on the risk of GIB in Asian patients with AF, treated with oral anticoagulants (OACs), and with a prior history of upper GIB. METHODS: Using a nationwide claims database, OAC-naïve patients with AF and a history of upper GIB before initiating OAC treatment between January 2010 and April 2018 were included. Patients were categorized into 10 groups according to the index OAC (warfarin, rivaroxaban, dabigatran, apixaban, and edoxaban) and whether or not they received PPI co-therapy, and were followed up for incidence of major GIB. RESULTS: Among a total of 42,048 patients, 40% were prescribed PPIs as co-therapy with OACs. Over a median 0.6 years (interquartile ranges 0.2-1.7 years) of follow-up, rivaroxaban use without PPIs showed the highest crude incidence of major GIB (2.62 per 100 person-years), followed by the use of warfarin without a PPI (2.20 per 100 person-years). Compared to the patients without PPI use, PPI co-therapy was associated with a significantly lower risk of major GIB, by 40% and 36%, in the rivaroxaban and warfarin groups, respectively. In dabigatran, apixaban, and edoxaban users, PPI co-therapy did not show a significant reduction in the risk of major GIB. CONCLUSION: Among patients with AF receiving anticoagulant treatment and with a prior history of upper GIB, PPI co-therapy was associated with a significant reduction in the risk of major GIB in patients treated with rivaroxaban and warfarin.


Assuntos
Fibrilação Atrial , Acidente Vascular Cerebral , Trato Gastrointestinal Superior , Administração Oral , Anticoagulantes , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/epidemiologia , Dabigatrana , Hemorragia Gastrointestinal/induzido quimicamente , Hemorragia Gastrointestinal/diagnóstico , Hemorragia Gastrointestinal/epidemiologia , Humanos , Inibidores da Bomba de Prótons/efeitos adversos , Rivaroxabana , Acidente Vascular Cerebral/epidemiologia , Varfarina
20.
J Med Internet Res ; 24(5): e37970, 2022 05 09.
Artigo em Inglês | MEDLINE | ID: mdl-35532989

RESUMO

BACKGROUND: There is insufficient evidence for the use of single-lead electrocardiogram (ECG) monitoring with an adhesive patch-type device (APD) over an extended period compared to that of the 24-hour Holter test for atrial fibrillation (AF) detection. OBJECTIVE: In this paper, we aimed to compare AF detection by the 24-hour Holter test and 72-hour single-lead ECG monitoring using an APD among patients with AF. METHODS: This was a prospective, single-center cohort study. A total of 210 patients with AF with clinical indications for the Holter test at cardiology outpatient clinics were enrolled in the study. The study participants were equipped with both the Holter device and APD for the first 24 hours. Subsequently, only the APD continued ECG monitoring for an additional 48 hours. AF detection during the first 24 hours was compared between the two devices. The diagnostic benefits of extended monitoring using the APD were evaluated. RESULTS: A total of 200 patients (mean age 60 years; n=141, 70.5% male; and n=59, 29.5% female) completed 72-hour ECG monitoring with the APD. During the first 24 hours, both monitoring methods detected AF in the same 40/200 (20%) patients (including 20 patients each with paroxysmal and persistent AF). Compared to the 24-hour Holter test, the APD increased the AF detection rate by 1.5-fold (58/200; 29%) and 1.6-fold (64/200; 32%) with 48- and 72-hour monitoring, respectively. With the APD, the number of newly discovered patients with paroxysmal AF was 20/44 (45.5%), 18/44 (40.9%), and 6/44 (13.6%) at 24-, 48-, and 72-hour monitoring, respectively. Compared with 24-hour Holter monitoring, 72-hour monitoring with the APD increased the detection rate of paroxysmal AF by 2.2-fold (44/20). CONCLUSIONS: Compared to the 24-hour Holter test, AF detection could be improved with 72-hour single-lead ECG monitoring with the APD.


Assuntos
Fibrilação Atrial , Fibrilação Atrial/diagnóstico , Estudos de Coortes , Eletrocardiografia , Eletrocardiografia Ambulatorial/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA