Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 48
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Vasc Interv Radiol ; 34(7): 1200-1213, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37001638

RESUMO

Primary liver malignancy, of which hepatocellular carcinoma (HCC) is the most common type, is the second most common cause of death due to cancer worldwide. Given the historically poor prognosis of liver cancer, there has been major research on its treatment options, with significant advancements over the last decade. Transarterial radioembolization (TARE) is a locoregional treatment option for HCC that involves transarterial delivery of the ß-emitter yttrium-90 via resin or glass microspheres to arterialized tumor vasculature, delivering a tumoricidal dose to the tumor. The recent 2022 update of the Barcelona Clinic Liver Cancer (BCLC) treatment algorithm features a more prominent role for locoregional treatment, including the incorporation of radioembolization for very-early-stage (BCLC-0) and early-stage (BCLC-A) diseases. This review provides a contemporary summary of the evolving role of TARE in treatment of HCC in light of recent and upcoming trials.


Assuntos
Carcinoma Hepatocelular , Embolização Terapêutica , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/radioterapia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/radioterapia , Embolização Terapêutica/efeitos adversos , Radioisótopos de Ítrio/efeitos adversos , Microesferas
2.
J Vasc Interv Radiol ; 33(4): 410-415.e1, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35365283

RESUMO

Percutaneous glue embolization was investigated as a treatment for bronchopleural fistulae (BPFs) and alveolar-pleural fistulae (APFs) associated with persistent air leak. Seven consecutive patients with persistent air leak were treated with percutaneous glue embolization of the BPF/APF from both iatrogenic and spontaneous causes. Treatment was performed using direct n-butyl cyanoacrylate (nBCA) glue injection for discrete, visible fistulae (n = 4), fibrin glue spray for suspected tiny multifocal leaks (n = 2), or both (n = 1). The number of treatments required per patient was 1 (n = 3), 2 (n = 3), or 3 (n = 1). Technical success was achieved in all cases. Follow-up showed resolution of all air leaks, with mean chest tube removal at 7.1 days after the embolization. The follow-up duration ranged from 2 to 47 months. No significant procedure-related morbidity, mortality, or recurrence was encountered. Percutaneous treatment for persistent BPFs and APFs showed good efficacy in this small case series and warrants further investigation.


Assuntos
Fístula Brônquica , Embucrilato , Doenças Pleurais , Brônquios , Fístula Brônquica/diagnóstico por imagem , Fístula Brônquica/etiologia , Fístula Brônquica/terapia , Tubos Torácicos , Humanos , Doenças Pleurais/diagnóstico por imagem , Doenças Pleurais/etiologia , Doenças Pleurais/terapia
3.
Emerg Radiol ; 29(3): 615-619, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35182255

RESUMO

Popliteal vein aneurysms (PVAs) are rare entities, with less than 300 hundred cases reported in the global literature. Despite their rarity, they have immense consequences, having the potential to lead to life-threatening conditions such as pulmonary embolisms and even death. Hence, it is vital for clinicians to be aware of this condition. In this paper, we report a case of PVA and its imaging features seen on the varying imaging modalities. Diagnosis often may not be straightforward as it can mimic other non-vascular or soft tissue masses, hence understanding and appreciating its specific imaging appearances is essential. Generally, PVAs are treated surgically with good outcomes with no reported mortality or recurrence of pulmonary embolism.


Assuntos
Aneurisma , Embolia Pulmonar , Aneurisma/diagnóstico por imagem , Aneurisma/cirurgia , Humanos , Perna (Membro) , Veia Poplítea/diagnóstico por imagem , Embolia Pulmonar/diagnóstico por imagem , Embolia Pulmonar/terapia
4.
Radiology ; 300(3): 715-724, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34227886

RESUMO

Background There is a paucity of randomized trials demonstrating superior efficacy of drug-coated balloon angioplasty (DCBA) compared with conventional percutaneous transluminal angioplasty (PTA) for below-the-knee arterial disease in patients with -critical limb ischemia. Purpose To compare DCBA versus PTA for below-the-knee lesions in participants with critical limb ischemia through 12 months. Materials and Methods In this prospective, randomized, two-center, double-blind superiority study, participants with critical limb ischemia with rest pain or tissue loss with atherosclerotic disease in the native below-the-knee arteries were randomly assigned (in a one-to-one ratio) to DCBA or PTA after stratification for diabetes and renal failure between November 2013 and October 2017. The primary efficacy end point was angiographic primary patency at 6 months analyzed on an intention-to-treat basis. Secondary end points through 12 months were composed of major adverse events including death and major amputations, wound healing, limb salvage, clinically driven target-lesion revascularization, and amputation-free survival. Primary and binary secondary end points, analyzed by using generalized-linear model and time-to-event analyses, were estimated with Kaplan-Meier survival curves and hazard ratios (Cox regression). Results Seventy participants (mean age, 61 years ± 10 [standard deviation]; 43 men) in the DCBA group and 68 (mean age, 64 years ± 10; 50 men) in the PTA group were evaluated. The percentage of patients with angiographic primary patency at 6 months was 43% (30 of 70) in the DCBA group and 38% (26 of 68) in the PTA group (P = .48). Through 12 months, the percentage of deaths was similar: 21% in the DCBA group and 16% in the PTA group (P = .43). Amputation-free survival rate assessed with Kaplan-Meier curves differed through 12 months: 59% (41 of 70) in the DCBA group compared with 78% (53 of 68) in the PTA group (P = .01). Conclusion In participants with critical limb ischemia, the drug-coated balloon angioplasty group and the conventional percutaneous transluminal angioplasty group had similar primary patency rates at 6 months after treatment of below-the-knee arteries. Amputation-free survival rates through 12 months were higher in the percutaneous transluminal angioplasty group. © RSNA, 2021 Online supplemental material is available for this article.


Assuntos
Angioplastia com Balão/instrumentação , Isquemia/cirurgia , Extremidade Inferior/irrigação sanguínea , Paclitaxel/administração & dosagem , Doença Arterial Periférica/cirurgia , Moduladores de Tubulina/administração & dosagem , Angiografia , Meios de Contraste , Método Duplo-Cego , Sistemas de Liberação de Medicamentos , Feminino , Humanos , Iohexol , Isquemia/diagnóstico por imagem , Salvamento de Membro , Extremidade Inferior/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/diagnóstico por imagem , Estudos Prospectivos
5.
J Vasc Interv Radiol ; 32(11): 1536-1545.e38, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34166803

RESUMO

PURPOSE: To evaluate the efficacy of hepatic arterial infusion (HAI), conventional transarterial chemoembolization, drug-eluting embolic transarterial chemoembolization (DEE-TACE), transarterial radioembolization, and their combinations with systemic chemotherapy (SCT) for unresectable colorectal liver metastases. METHODS: A search was conducted on Embase, Scopus, PubMed, and Web of Science for prospective nonrandomized studies and randomized controlled trials (RCTs) from inception to June 20, 2020. Survival data of patients were recovered from original Kaplan-Meier curves by exploiting a graphical reconstructive algorithm. One-stage meta-analyses were conducted for the median overall survival (OS), survival rates (SRs), and restricted mean survival time (RMST), whereas two-stage meta-analyses of proportions were conducted to determine response rates (RRs) and conversion to resection rates (CRRs). RESULTS: A total of 71 prospective nonrandomized studies and 21 RCTs were identified, comprising 6,695 patients. Among patients treated beyond the first-line, DEE-TACE + SCT (n = 152) had the best survival outcomes of median OS of 26.5 (95% confidence interval [CI], 22.5-29.1) months and a 3-year RMST of 23.6 (95% CI, 21.8-25.5) months. Upon further stratification by publication year, DEE-TACE + SCT appeared to consistently have the highest pooled SRs at 1 year (81.9%) and 2 years (66.1%) in recent publications (2015-2020). DEE-TACE + SCT and HAI + SCT had the highest pooled RRs of 56.7% (I2 = 0.90) and 62.6% (I2 = 0.87) and pooled CRRs of 35.5% (I2 = 0.00) and 30.3% (I2 = 0.80), respectively. CONCLUSIONS: Albeit significant heterogeneity, the paucity of high-quality evidence, and the noncomparative nature of all analyses, the overall evidence suggests that patients treated with DEE-TACE + SCT have the best oncological outcomes and greatest potential to be converted for resection.


Assuntos
Braquiterapia , Carcinoma Hepatocelular , Quimioembolização Terapêutica , Neoplasias Colorretais , Embolização Terapêutica , Neoplasias Hepáticas , Carcinoma Hepatocelular/terapia , Quimioembolização Terapêutica/efeitos adversos , Neoplasias Colorretais/terapia , Embolização Terapêutica/efeitos adversos , Humanos , Neoplasias Hepáticas/terapia , Taxa de Sobrevida , Resultado do Tratamento
6.
J Vasc Interv Radiol ; 31(12): 1969-1977.e1, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33139186

RESUMO

PURPOSE: To review outcomes of patients with critical limb ischemia (CLI) who underwent conventional percutaneous transluminal angioplasty (PTA) as first-line treatment for revascularization. MATERIALS AND METHODS: Retrospective review of 3,303 angioplasty procedures on 2,402 limbs in 1,968 patients with CLI was conducted. Mean patient age was 68 years ± 11, and 1,057 patients (54%) were male. Diabetes mellitus (DM) was present in 1,736 patients (88%), and end-stage renal disease (ESRD) in 579 (29%). A majority of patients (90%) had tissue loss. Limb salvage rates were generated by Kaplan-Meier plot. Univariate and multivariate Cox regression analysis was conducted to investigate associations between clinical predictors and time-to-event outcome. RESULTS: Limb salvage rates at 1, 3, 5, and 10 years were 75%, 73%, 72%, and 62%, respectively, and overall survival rates were 79%, 64%, 56%, and 34%, respectively. In multivariable Cox regression analysis with the outcome of major amputation, significant predictors included age < 69 years (P = .032), Malay race (P = .029), DM (P < .001), history of cerebral vascular disease (P = .003), ESRD (P < .001), Rutherford classification (P = .042), repeat intervention (P = .034), and number of straight-line flows (P < .001) and plantar arch integrity (P < .001) on completion angiography. Significant associations with mortality were age < 69 years (P < .001), male sex (P = .030), Malay race (P = .027), history of ischemic heart disease (P < .001), ESRD (P < .001), and repeat intervention (P < .001). CONCLUSIONS: PTA as first-line revascularization for patients with CLI is safe and effective. Further studies are suggested to validate the outcome predictive model.


Assuntos
Angioplastia com Balão , Isquemia/terapia , Salvamento de Membro , Doença Arterial Periférica/terapia , Idoso , Amputação Cirúrgica , Angioplastia com Balão/efeitos adversos , Angioplastia com Balão/instrumentação , Angioplastia com Balão/mortalidade , Comorbidade , Estado Terminal , Bases de Dados Factuais , Feminino , Humanos , Isquemia/diagnóstico por imagem , Isquemia/mortalidade , Salvamento de Membro/efeitos adversos , Salvamento de Membro/mortalidade , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/mortalidade , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Singapura , Stents , Centros de Atenção Terciária , Fatores de Tempo , Resultado do Tratamento
7.
J Endovasc Ther ; 25(2): 252-254, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29409379

RESUMO

PURPOSE: To describe a case of extrinsic compression of the Ovation stent-graft following glue embolization for type II endoleak. CASE REPORT: A 75-year-old man with a past history of ischemic heart disease and endovascular aneurysm repair with an Ovation stent-graft was admitted for treatment of type II endoleaks from the right L2 and left L4 lumbar arteries with egress via the inferior mesenteric and right L4 lumbar arteries, respectively. Successful embolization was performed via a translumbar sac puncture with a combination of coils and histoacryl glue. On final angiography severe lumen narrowing of the unsupported portion of the Ovation stent-graft was seen owing to extrinsic compression by the glue. This was successfully salvaged with percutaneous transarterial kissing balloon angioplasty. CONCLUSION: Aortic lumen narrowing caused by extrinsic compression of an Ovation stent-graft following glue embolization of type II endoleak is an unusual and potentially problematic complication.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Embolização Terapêutica/efeitos adversos , Embucrilato/efeitos adversos , Endoleak/terapia , Procedimentos Endovasculares/instrumentação , Oclusão de Enxerto Vascular/etiologia , Stents , Idoso , Angioplastia com Balão , Implante de Prótese Vascular/efeitos adversos , Endoleak/diagnóstico , Endoleak/etiologia , Procedimentos Endovasculares/efeitos adversos , Oclusão de Enxerto Vascular/diagnóstico por imagem , Oclusão de Enxerto Vascular/fisiopatologia , Oclusão de Enxerto Vascular/terapia , Humanos , Masculino , Desenho de Prótese , Grau de Desobstrução Vascular
8.
Radiographics ; 37(2): 665-680, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28287940

RESUMO

Complications related to percutaneous biliary tract interventions (PBTIs) can range from access site discomfort to life-threatening vascular complications. These complications are relatively uncommon, and most of them are self-limiting. However, major complications for which an increased level of patient care and/or a prolonged hospital stay are required and that may lead to death-albeit rarely-can occur. Some of the most common complications related to PBTI include pain, infection, bile leakage, and catheter blockage. These conditions can be easily recognized by using the patient's clinical history and laboratory examination results. However, the more uncommon complications, such as life-threatening hemobilia, acute pancreatitis, and catheter and stent fractures, may have nonspecific clinical manifestations, and the underlying pathologic condition may be found only when it is being sought specifically. It is important that diagnostic and interventional radiologists be aware of the wide spectrum of PBTI-related complications, as early recognition and treatment may prevent catastrophic situations. In addition, knowledge of the different treatment options is essential for guidance in interventional radiology procedures such as transarterial control of hemobilia, imaging-guided direct percutaneous embolization of pseudoaneurysms, and percutaneous treatment of catheter- and stent-related complications such as fractures. The authors review a wide spectrum of complications associated with PBTI and the percutaneous management of these conditions. They also highlight valuable lessons learned from morbidity and mortality rounds at a high-volume tertiary care center. ©RSNA, 2017.


Assuntos
Doenças Biliares/cirurgia , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/terapia , Radiologia Intervencionista/métodos , Humanos
9.
Can Assoc Radiol J ; 66(4): 363-7, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26387729

RESUMO

PURPOSE: The purpose was to compare performance of diagnostic workstation monitors and the Apple iPad 2 (Cupertino, CA) in interpretation of emergency computed tomography (CT) brain studies. METHODS: Two experienced radiologists interpreted 100 random emergency CT brain studies on both on-site diagnostic workstation monitors and the iPad 2 via remote access. The radiologists were blinded to patient clinical details and to each other's interpretation and the study list was randomized between interpretations on different modalities. Interobserver agreement between radiologists and intraobserver agreement between modalities was determined and Cohen kappa coefficients calculated for each. Performance with regards to urgent and nonurgent abnormalities was assessed separately. RESULTS: There was substantial intraobserver agreement of both radiologists between the modalities with overall calculated kappa values of 0.959 and 0.940 in detecting acute abnormalities and perfect agreement with regards to hemorrhage. Intraobserver agreement kappa values were 0.939 and 0.860 for nonurgent abnormalities. Interobserver agreement between the 2 radiologists for both diagnostic monitors and the iPad 2 was also substantial ranging from 0.821-0.860. CONCLUSIONS: The iPad 2 is a reliable modality in the interpretation of CT brain studies in them emergency setting and for the detection of acute and chronic abnormalities, with comparable performance to standard diagnostic workstation monitors.


Assuntos
Plantão Médico , Encefalopatias/diagnóstico por imagem , Computadores de Mão , Serviços Médicos de Emergência/métodos , Interpretação de Imagem Assistida por Computador/instrumentação , Tomografia Computadorizada Multidetectores/instrumentação , Sistemas de Informação em Radiologia/instrumentação , Telerradiologia/instrumentação , Encéfalo/diagnóstico por imagem , Isquemia Encefálica/diagnóstico por imagem , Humanos , Aumento da Imagem/instrumentação , Variações Dependentes do Observador , Valores de Referência , Estudos Retrospectivos
11.
Med Phys ; 2024 Aug 14.
Artigo em Inglês | MEDLINE | ID: mdl-39140650

RESUMO

BACKGROUND: Fluoroscopy guided interventions (FGIs) pose a risk of prolonged radiation exposure; personalized patient dosimetry is necessary to improve patient safety during these procedures. However, current FGIs systems do not capture the precise exposure regions of the patient, making it challenging to perform patient-procedure-specific dosimetry. Thus, there is a pressing need to develop approaches to extract and use this information to enable personalized radiation dosimetry for interventional procedures. PURPOSE: To propose a deep learning (DL) approach for the automatic localization of 3D anatomical landmarks on randomly collimated and magnified 2D head fluoroscopy images. MATERIALS AND METHODS: The model was developed with datasets comprising 800 000 pseudo 2D synthetic images (mixture of vessel-enhanced and non-enhancement), each with 55 annotated anatomical landmarks (two are landmarks for eye lenses), generated from 135 retrospectively collected head computed tomography (CT) volumetric data. Before training, dynamic random cropping was performed to mimic the varied field-size collimation in FGI procedures. Gaussian-distributed additive noise was applied to each individual image to enhance the robustness of the DL model in handling image degradation that may occur during clinical image acquisition in a clinical environment. The model was trained with 629 370 synthetic images for approximately 275 000 iterations and evaluated against a synthetic image test set and a clinical fluoroscopy test set. RESULTS: The model shows good performance in estimating in- and out-of-image landmark positions and shows feasibility to instantiate the skull shape. The model successfully detected 96.4% and 92.5% 2D and 3D landmarks, respectively, within a 10 mm error on synthetic test images. It demonstrated an average of 3.6 ± 2.3 mm mean radial error and successfully detected 96.8% 2D landmarks within 10 mm error on clinical fluoroscopy images. CONCLUSION: Our deep-learning model successfully localizes anatomical landmarks and estimates the gross shape of skull structures from collimated 2D projection views. This method may help identify the exposure region required for patient-specific organ dosimetry in FGIs procedures.

12.
Diagn Interv Radiol ; 29(2): 318-325, 2023 03 29.
Artigo em Inglês | MEDLINE | ID: mdl-36987983

RESUMO

Percutaneous thermal ablation of hepatic tumors is accepted as a safe, reliable, and cost-effective therapeutic option for treating hepatocellular carcinoma and hepatic metastases. However, operators should be familiar with the myriad of vascular and non-vascular complications that can occur post-ablation and that are described in the literature. This review will focus on the various vascular complications related to percutaneous thermal ablation of hepatic tumors and discuss strategies to avoid and manage these complications.


Assuntos
Carcinoma Hepatocelular , Ablação por Cateter , Neoplasias Hepáticas , Humanos , Ablação por Cateter/efeitos adversos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Neoplasias Hepáticas/patologia , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/cirurgia , Carcinoma Hepatocelular/patologia , Resultado do Tratamento
13.
Sci Rep ; 13(1): 16980, 2023 10 09.
Artigo em Inglês | MEDLINE | ID: mdl-37813906

RESUMO

Hepatic venous pressure gradient (HVPG) is an accurate measure of portal hypertension in cirrhosis. However, the effect of catheter tip distance from hepatic vein ostium (HVO) on HVPG is unknown. We performed a retrospective study on 228 patients with 307 HVPGs in our institution. The objectives of this study were to assess the effect of catheter position on the validity of HVPG and its prognostication in cirrhosis. In this study, free hepatic vein pressure (FHVP) was considered optimal when difference between FHVP and inferior vena cava pressure was ≤ 2 mmHg. HVPG progressively decreased (p < 0.001) when measured at increasing distance from HVO due to an increasing FHVP (p = 0.036) but an unchanged wedged hepatic vein pressure (p = 0.343). Catheter tip distance > 5 to ≤ 8 cm [odds ratio {OR} 0.16 (95% CI 0.05-0.47), p = 0.001] and > 8 cm [OR 0.14 (95% CI 0.04-0.47), p = 0.002] compared to ≤ 3 cm from HVO were independent predictors of not achieving optimal FHVP. Baseline HVPG ≥ 16 mmHg was strongly associated with deaths due to cirrhosis and liver transplantation for end-stage liver disease compared to HVPG < 16 mmHg when FHVP was optimal (p < 0.001) but not when it was suboptimal (p = 0.359). Our study showed that FHVP is spuriously elevated when measured at > 5 cm from HVO, resulting in inaccurately low HVPG.


Assuntos
Veias Hepáticas , Cirrose Hepática , Humanos , Estudos Retrospectivos , Cirrose Hepática/complicações , Fibrose , Pressão na Veia Porta , Catéteres
14.
Phys Eng Sci Med ; 46(4): 1535-1552, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37695509

RESUMO

In fluoroscopy-guided interventions (FGIs), obtaining large quantities of labelled data for deep learning (DL) can be difficult. Synthetic labelled data can serve as an alternative, generated via pseudo 2D projections of CT volumetric data. However, contrasted vessels have low visibility in simple 2D projections of contrasted CT data. To overcome this, we propose an alternative method to generate fluoroscopy-like radiographs from contrasted head CT Angiography (CTA) volumetric data. The technique involves segmentation of brain tissue, bone, and contrasted vessels from CTA volumetric data, followed by an algorithm to adjust HU values, and finally, a standard ray-based projection is applied to generate the 2D image. The resulting synthetic images were compared to clinical fluoroscopy images for perceptual similarity and subject contrast measurements. Good perceptual similarity was demonstrated on vessel-enhanced synthetic images as compared to the clinical fluoroscopic images. Statistical tests of equivalence show that enhanced synthetic and clinical images have statistically equivalent mean subject contrast within 25% bounds. Furthermore, validation experiments confirmed that the proposed method for generating synthetic images improved the performance of DL models in certain regression tasks, such as localizing anatomical landmarks in clinical fluoroscopy images. Through enhanced pseudo 2D projection of CTA volume data, synthetic images with similar features to real clinical fluoroscopic images can be generated. The use of synthetic images as an alternative source for DL datasets represents a potential solution to the application of DL in FGIs procedures.


Assuntos
Aprendizado Profundo , Radiologia Intervencionista , Radiografia , Fluoroscopia/métodos , Algoritmos
16.
Cardiovasc Intervent Radiol ; 45(11): 1663-1669, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35237860

RESUMO

PURPOSE: Drug-coated balloon angioplasty (DCBA) has been studied as a potentially superior option compared to conventional percutaneous transluminal angioplasty (PTA) in treating below-the-knee (BTK) arteries in chronic limb-threatening ischemia (CLTI). The aim of this study is to examine the cost-effectiveness of DCBA versus PTA in BTK arteries based on a randomized controlled trial. MATERIAL AND METHODS: A prospective economic study was embedded in a randomized controlled trial of 138 patients with CLTI. Resource use and health outcomes were assessed at baseline, and at 3, 6 and 12 months post-intervention. Costs were calculated from a societal perspective and health outcomes measured using quality-adjusted life years with probabilistic sensitivity analysis performed to account for subject heterogeneity. RESULTS: Compared with participants randomized to receive PTA, participants randomized to DCBA gained an average baseline-adjusted quality-adjusted life years (QALYs) of .012 while average total costs were USD$1854 higher; this translates to an incremental cost-effectiveness ratio (ICER) of US$154,500 additional cost per QALY gained. However, the estimate of ICER had substantial variance with only 48% of bootstrap ICERs meeting a benchmark threshold of US$57,705 (the average gross domestic product (GDP) per capita of Singapore). CONCLUSION: The use of DCBA in BTK arteries in CLTI patients was not cost-effective compared with PTA. LEVEL OF EVIDENCE: 2, Randomized trial.


Assuntos
Angioplastia com Balão , Isquemia Crônica Crítica de Membro , Humanos , Análise Custo-Benefício , Estudos Prospectivos , Resultado do Tratamento , Angioplastia com Balão/efeitos adversos , Artéria Poplítea , Angioplastia , Isquemia/terapia
17.
Cardiovasc Intervent Radiol ; 45(5): 646-653, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35059796

RESUMO

PURPOSE: To study the safety and efficacy of cutting balloon angioplasty (CBA) followed by paclitaxel drug-coated balloon (PCB) angioplasty for recurrent venous lesions in arteriovenous fistulas (AVFs). MATERIALS AND METHODS: We conducted a prospective single-arm cohort study of CBA followed by PCB angioplasty for recurrent AVF stenoses between September 2017 and April 2019. In total, 44 participants were recruited. Target lesions were included if they had recurred within 12 months post-angioplasty, were > = 0.5 cm upstream from the arteriovenous anastomosis, and did not involve the central veins. Up to two non-target lesions per circuit/participant with the same definition were allowed. Lesions were considered separate when there was an intervening 2-cm segment of normal vessel. Technical success was defined as complete lesion effacement on angioplasty. End-points of target and circuit patency were evaluated clinically at 3, 6, and 12 months post-procedure. RESULT: Technical success was 96% (42/44): Two participants were excluded from analysis due to the need for high-pressure balloon angioplasty as the target lesions did not efface with CBA. The median follow-up duration was 337.5 days. Mean stenosis pre- and post-angioplasty was 69.0% (51.6-84.8) and 20.8% (0-44.8), respectively. The target lesion primary, primary assisted and circuit patency for the entire study population (n = 42) were 61.6 ± 7.8%, 92.7 ± 4.0%, and 54.7 ± 7.9%, respectively, at 12 months. For participants without non-target lesions (n = 22), the rates were 77.3 ± 8.9%, 90.9 ± 6.1%, and 60.7 ± 11.0%, respectively, at 12 months. CONCLUSION: CBA followed by PCB angioplasty appears safe and feasible for treatment of recurrent venous lesions in dysfunctional AVFs.


Assuntos
Angioplastia com Balão , Fístula Arteriovenosa , Derivação Arteriovenosa Cirúrgica , Angioplastia com Balão/métodos , Materiais Revestidos Biocompatíveis , Estudos de Coortes , Constrição Patológica/terapia , Humanos , Paclitaxel , Estudos Prospectivos , Diálise Renal , Resultado do Tratamento , Grau de Desobstrução Vascular
18.
Cancer Invest ; 29(5): 365-9, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21599513

RESUMO

p53 and HER-2 coexpression in breast cancer has been controversial. These markers were tested using immunohistochemistry and HercepTest. HER-2 expression is related to reduced breast cancer survival (p = .02) . p53 expression relates to HER-2 expression (p = .029). Coexpression between p53 and HER-2 has no relation to prognosis. On univariate and multivariate analysis, combination of HER-2 positive and p53 negative expression was associated with a poor prognosis (p = .018 and p = .027, respectively), while the combination of HER-2 negative and p53 positive expression was associated with a favorable prognosis (p = .022 and p = .010, respectively). Therefore the expression of these markers should be considered collectively.


Assuntos
Biomarcadores Tumorais/análise , Neoplasias da Mama/química , Receptor ErbB-2/análise , Proteína Supressora de Tumor p53/análise , Adulto , Idoso , Idoso de 80 Anos ou mais , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Neoplasias da Mama/mortalidade , Neoplasias da Mama/patologia , Neoplasias da Mama/terapia , Quimioterapia Adjuvante , Feminino , Humanos , Imuno-Histoquímica , Irlanda , Estimativa de Kaplan-Meier , Mastectomia , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Modelos de Riscos Proporcionais , Recidiva , Estudos Retrospectivos , Fatores de Risco , Taxa de Sobrevida , Fatores de Tempo , Resultado do Tratamento
20.
Radiol Case Rep ; 16(9): 2474-2477, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34257783

RESUMO

Dissecting intramural hematoma of esophagus (DIHE) is an uncommon entity, characterized by accumulation of blood within the esophageal wall and usually managed conservatively. Only in rare circumstances, DIHE is associated with massive life-threatening hemorrhage requiring emergency treatment. We present a case of DIHE associated with cardiovascular collapse and treated by transcatheter arterial embolization. Transcatheter arterial embolization is a rare treatment option for DIHE associated with hemodynamic instability and only a handful of cases have been reported in the literature.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA