RESUMO
Structural valve deterioration after aortic root replacement (ARR) surgery may be treated by transcatheter valve-in-valve (ViV-TAVI) intervention. However, several technical challenges and outcomes are not well described. The aim of the present review was to analyze the outcomes of ViV-TAVI in deteriorated ARR. This review included studies reporting any form of transcatheter valvular intervention in patients with a previous ARR. All forms of ARR were considered, as long as the entire root was replaced. Pubmed, ScienceDirect, SciELO, DOAJ, and Cochrane library databases were searched until September 2023. Overall, 86 patients were included from 31 articles that met our inclusion criteria out of 741 potentially eligible studies. In the entire population, the mean time from ARR to reintervention was 11.0 years (range: 0.33-22). The most frequently performed techniques/grafts for ARR was homograft (67.4%) and the main indication for intervention was aortic regurgitation (69.7%). Twenty-three articles reported no postoperative complications. Six (7.0%) patients required permanent pacemaker implantation (PPI) after the ViV-TAVI procedure, and 4 (4.7%) patients had a second ViV-TAVI implant. There were three device migrations (3.5%) and 1 stroke (1.2%). Patients with previous ARR present a high surgical risk. ViV-TAVI can be considered in selected patients, despite unique technical challenges that need to be carefully addressed according to the characteristics of the previous surgery and on computed tomography analysis.
Assuntos
Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/etiologia , Prótese Vascular , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/efeitos adversos , Estimulação Cardíaca Artificial , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Falha de Prótese , Recuperação de Função Fisiológica , Medição de Risco , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do TratamentoRESUMO
OBJECTIVES: Report contemporary outcomes in patients included in the Mitragister registry and treated with transcatheter mitral valve implantation for failed surgical annuloplasty rings or deteriorated bioprosthesis. BACKGROUND: Midterm survival rates have been reported, but little is known about contemporary morbimortality endpoints. METHODS: The primary safety outcome was the technical success rate. The primary efficacy composite endpoint was a composite of cardiovascular mortality and heart failure hospitalizations. RESULTS: From 2016 to 2021, 102 patients (median age: 81 [74;84] years, 61% female, Euroscore II 11.0% [7.8;16.0]) undergoing valve-in-valve (ViV; n = 89) or valve-in-ring (ViR; n = 13) procedures were consecutively included. At baseline, ViR group patients had worse left ventricular ejection fraction (50% vs. 60%; p = 0.004) and more frequently severe regurgitation (46% vs. 15%; p = 0.014). The primary safety outcome was 95%: 77% and 98% in the ViR and ViV populations, respectively, (p = 0.014). At intermediate follow-up (6-12 months) clinical improvement was notable, 88% of the patients were in NYHA class ≤ II (vs. 25% at baseline; p < 0.001). At a mean follow-up of 17.1 ± 11.0 months, the primary efficacy composite reached 27%. By multivariate analysis, paravalvular leak (PVL) was the only independent predictor (hazard ratio: 2.39, 95% confidence interval: 1.08-5.29; p = 0.031) while ViR was not found statistically associated (p = 0.456). CONCLUSIONS: This study confirms the safety and efficacy of the mitral ViV procedure. ViR patients appear at higher risk of procedural complications. The presence of PVL could be associated with markedly worse midterm prognosis. Whatever the intervention, procedural strategies to reduce PVL incidence remain to be assessed to prevent latter adverse outcomes.
Assuntos
Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Idoso de 80 Anos ou mais , Bioprótese/efeitos adversos , Cateterismo Cardíaco/métodos , Feminino , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Falha de Prótese , Sistema de Registros , Volume Sistólico , Resultado do Tratamento , Função Ventricular EsquerdaRESUMO
BACKGROUND: No randomized study powered to compare balloon expandable (BE) with self expanding (SE) transcatheter heart valves (THVs) on individual end points after transcatheter aortic valve replacement has been conducted to date. METHODS: From January 2013 to December 2015, the FRANCE-TAVI nationwide registry (Registry of Aortic Valve Bioprostheses Established by Catheter) included 12 141 patients undergoing BE-THV (Edwards, n=8038) or SE-THV (Medtronic, n=4103) for treatment of native aortic stenosis. Long term mortality status was available in all patients (median 20 months; interquartile range, 14 to 30). Patients treated with BE-THV (n=3910) were successfully matched 1:1 with 3910 patients treated with SE-THV by using propensity score (25 clinical, anatomical, and procedural variables) and by date of the procedure (within 3 months). The first coprimary outcome was ≥ moderate occurrence of paravalvular regurgitation or in-hospital mortality, or both. The second coprimary outcome was 2-year all-cause mortality. RESULTS: In propensity-matched analyses, the incidence of the first coprimary outcome was higher with SE-THV (19.8%) compared with BE-THV (11.9%; relative risk, 1.68 [95% CI, 1.46-1.91]; P<0.0001). Each component of the outcome was also higher in patients receiving SE-THV: ≥ moderate paravalvular regurgitation (15.5% versus 8.3%; relative risk, 1.90 [95% CI, 1.63-2.22]; P<0.0001) and in hospital mortality (5.6% versus 4.2%; relative risk, 1.34 [95% CI, 1.07-1.66]; P=0.01). During follow up, all cause mortality occurred in 899 patients treated with SE-THV (2-year mortality, 29.8%) and in 801 patients treated with BE-THV (2-year mortality, 26.6%; hazard ratio, 1.17 [95% CI, 1.06-1.29]; P=0.003). Similar results were found using inverse probability of treatment weighting using propensity score analysis. CONCLUSION: The present study suggests that use of SE-THV was associated with a higher risk of paravalvular regurgitation and higher in-hospital and 2-year mortality compared with use of BE-THV. These data strongly support the need for a randomized trial sufficiently powered to compare the latest generation of SE-THV and BE-THV. CLINICAL TRIAL REGISTRATION: https://www.clinicaltrials.gov. Unique identifier: NCT01777828.
Assuntos
Próteses Valvulares Cardíacas , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/cirurgia , Intervalo Livre de Doença , Feminino , Seguimentos , França/epidemiologia , Humanos , Masculino , Taxa de SobrevidaRESUMO
BACKGROUND: In patients who have chronic heart failure with reduced left ventricular ejection fraction, severe secondary mitral-valve regurgitation is associated with a poor prognosis. Whether percutaneous mitral-valve repair improves clinical outcomes in this patient population is unknown. METHODS: We randomly assigned patients who had severe secondary mitral regurgitation (defined as an effective regurgitant orifice area of >20 mm2 or a regurgitant volume of >30 ml per beat), a left ventricular ejection fraction between 15 and 40%, and symptomatic heart failure, in a 1:1 ratio, to undergo percutaneous mitral-valve repair in addition to receiving medical therapy (intervention group; 152 patients) or to receive medical therapy alone (control group; 152 patients). The primary efficacy outcome was a composite of death from any cause or unplanned hospitalization for heart failure at 12 months. RESULTS: At 12 months, the rate of the primary outcome was 54.6% (83 of 152 patients) in the intervention group and 51.3% (78 of 152 patients) in the control group (odds ratio, 1.16; 95% confidence interval [CI], 0.73 to 1.84; P=0.53). The rate of death from any cause was 24.3% (37 of 152 patients) in the intervention group and 22.4% (34 of 152 patients) in the control group (hazard ratio, 1.11; 95% CI, 0.69 to 1.77). The rate of unplanned hospitalization for heart failure was 48.7% (74 of 152 patients) in the intervention group and 47.4% (72 of 152 patients) in the control group (hazard ratio, 1.13; 95% CI, 0.81 to 1.56). CONCLUSIONS: Among patients with severe secondary mitral regurgitation, the rate of death or unplanned hospitalization for heart failure at 1 year did not differ significantly between patients who underwent percutaneous mitral-valve repair in addition to receiving medical therapy and those who received medical therapy alone. (Funded by the French Ministry of Health and Research National Program and Abbott Vascular; MITRA-FR ClinicalTrials.gov number, NCT01920698 .).
Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral/tratamento farmacológico , Insuficiência da Valva Mitral/cirurgia , Intervenção Coronária Percutânea , Idoso , Idoso de 80 Anos ou mais , Terapia Combinada , Feminino , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/terapia , Próteses Valvulares Cardíacas/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Hospitalização/estatística & dados numéricos , Humanos , Análise de Intenção de Tratamento , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/mortalidade , Falha de Prótese , Volume Sistólico , Resultado do Tratamento , Disfunção Ventricular Esquerda/etiologiaRESUMO
BACKGROUND: We examined the outcomes of older adults undergoing nontrans-femoral (non-TF) transcatheter aortic valve replacement (TAVR) procedures including trans-apical (TA), trans-aortic (TAo), trans-subclavian (TSub), and trans-carotid (TCa) techniques. METHODS AND RESULTS: This is an observational study of all consecutive older patients who underwent non-TF TAVR for symptomatic severe AS with Edwards Sapien (ES), Medtronic CoreValve, ES3 or Lotus Valve at three centers in France and the United States from 04/2008 to 02/2017. Baseline characteristics and clinical outcomes were defined according to VARC-2 criteria. Of 857 patients who received TAVR, 172 (20%) had an alternative access procedure. Of these, 45 (26%) were TA, 67 (39%) TAo, 17 (10%) TSub, and 43 (25%) TCa procedures. The preference for non-TF access site was different between the two countries (US: TA 39%, TAo 52%, TSub 9%; TCa 0% vs. France: TA 9%, TAo 23%, TSub 11%, and TCa 57%, P-value < .001). Most patients who underwent TAo TAVR were older women (median age: TA 82, TAo 84, TSub 81, TCa 81, P-value = 0.043; female gender: TA 32 (27%), TAo 30 (55%), TSub 10 (41%), TCa 27 (37%), P-value = .021). The predicted Society of Thoracic Surgery risk of mortality was similar among groups (TA 7%, TAo 7%, TSub 6%, TCa 7%, P-value= .738). No differences were observed in the frequency of para-valvular leak, intra-procedural bleeding, vascular complications, conversion to open-heart surgery, or development of acute kidney injury. The highest in-hospital mortality was observed in the TAo group (TA 2%, TAo 15%, TSub 0%, TCa 2%, P-value = .014). However, hospital length of stay, one-month, and one-year mortality were similar among non-TF techniques. CONCLUSION: Although regional differences exist in the choice of alternative access techniques, centers with high technical expertise can provide a safe alternative to traditional TF TAVR. TAo TAVR was associated with higher in-hospital mortality than other non-TF approaches, and this may have reflected patient rather than procedural factors. All alternative access techniques had similar mortality rates and clinical outcomes at one-year follow-up. Trans-carotid access is safe and feasible compared to other non-TF access techniques.
Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Cateterismo Periférico/métodos , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/mortalidade , Bases de Dados Factuais , Feminino , França , Mortalidade Hospitalar , Humanos , Masculino , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/cirurgia , Reoperação , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento , Estados UnidosRESUMO
BACKGROUND: Recently, the carotid artery has been used as an alternative approach for transcatheter aortic valve implantation (TAVI). The aim of this study was to prove the safety and feasibility of transcarotid (TC) vs. transfemoral (TF) TAVI. MethodsâandâResults: This retrospective study enrolled 726 consecutive patients with severe symptomatic aortic stenosis. All patients underwent TC-TAVI or TF-TAVI at Hôpital Haut-Lévèque, Bordeaux Heart University Hospital between September 2012 and October 2017. The TC-TAVI (n=83) and TF-TAVI (n=643) groups were compared statistically. The EuroSCORE II was significantly higher (8.2±6.7 vs. 6.4±5.5; P=0.007) and rates of current smoking, dyslipidemia and peripheral arterial disease were higher in the TC-TAVI than TF-TAVI group. All TC-TAVIs and 9.3% of TF-TAVIs were performed under general anesthesia. Radiation time was significantly shorter in the TC-TAVI than TF-TAVI group (14.5±6.0 vs. 23.0±10.8 min; P<0.001). Postimplant balloon valvuloplasty was performed more frequently in the TF-TAVI than TC-TAVI group (7.2% vs. 19.4%; P=0.006). Postoperative echocardiographic data were similar between the 2 groups, and there were no significant differences in 30-day mortality (8.4% vs. 5.0%; P=0.189) or stroke rate (1.2% vs. 2.6%; P=0.428) between the TF-TAVI and TC-TAVI groups. CONCLUSIONS: The feasibility and 30-day safety of TC-TAVI and TF-TAVI are similar. When TF-TAVI is not suitable anatomically for a particular patient, TC-TAVI is a preferable alternative.
Assuntos
Artérias Carótidas/cirurgia , Artéria Femoral/cirurgia , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/cirurgia , Valvuloplastia com Balão/estatística & dados numéricos , Ecocardiografia , Feminino , Humanos , Masculino , Mortalidade , Doença Arterial Periférica , Complicações Pós-Operatórias , Estudos Retrospectivos , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do TratamentoRESUMO
BACKGROUND: Recently, several trials have shown that closed-loop sedation is feasible. No study has used automated sedation in extremely frail patients, such as those scheduled for transcatheter aortic valve implantation (TAVI). We developed and tested a novel automated sedation system for this kind of population and surgery. The system integrates a decision support system that detects respiratory and hemodynamic events via smart alarms, which provide pertinent/related clinical suggestions and treatment options. The main objective was the feasibility of closed-loop sedation, defined as successful automated sedation without manual override. Secondary qualitative observations were clinical and controller performance. METHODS: Twenty patients scheduled for elective TAVI were enrolled. Sedation was administered via a closed-loop delivery system designed for propofol. The clinical performance of sedation was the efficacy to maintain a bispectral index (BIS) of 65. To evaluate the sedation performance, BIS values were stratified into 4 categories: excellent, very good, good, and inadequate sedation control, defined as BIS values within 10%, ranging from 11% to 20%, ranging from 21% to 30%, or >30% from the target value, respectively. The controller performance was calculated using Varvel parameters. Critical respiratory and hemodynamic events were documented. The former was defined as peripheral oxygen saturation <92% and/or respiratory rate <8/min, whereas the latter was considered a mean arterial pressure <60 mm Hg and/or heart rate <40 bpm. RESULTS: Automated sedation was successful in 19 patients undergoing TAVI. One patient was excluded from the final analysis because of conversion to general anesthesia. The secondary observations revealed that the clinical performance allowed an excellent to good control during 69% (99% confidence interval, 53%-77%; interquartile range, 59%-79%) of the sedation time. Fifteen patients presented critical respiratory episodes, with a median of 3 events per hour of sedation. Six patients presented critical hemodynamic episodes, with a median of 2 events per hour of procedure. CONCLUSIONS: The automated closed-loop sedation system tested could be used successfully for patients scheduled for a TAVI procedure. The results showed a satisfactory clinical performance of sedation control.
Assuntos
Anestesia Intravenosa/métodos , Anestésicos Intravenosos/administração & dosagem , Hipnóticos e Sedativos/administração & dosagem , Monitorização Intraoperatória/métodos , Propofol/administração & dosagem , Robótica/métodos , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Anestesia Intravenosa/efeitos adversos , Anestesia Intravenosa/instrumentação , Anestésicos Intravenosos/efeitos adversos , Automação , Alarmes Clínicos , Monitores de Consciência , Sistemas de Apoio a Decisões Clínicas , Procedimentos Cirúrgicos Eletivos , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Hemodinâmica/efeitos dos fármacos , Humanos , Hipnóticos e Sedativos/efeitos adversos , Masculino , Monitorização Intraoperatória/instrumentação , Projetos Piloto , Propofol/efeitos adversos , Estudos Prospectivos , Respiração/efeitos dos fármacos , Fatores de Risco , Robótica/instrumentação , Resultado do TratamentoRESUMO
OBJECTIVES: Innate immune system alterations, including dendritic cell loss, have been reproducibly observed in patients with septic shock and correlated to adverse outcomes or nosocomial infections. The goal of this study is to better understand the mechanisms behind this observation in order to better assess septic shock pathogenesis. DESIGN: Prospective, controlled experimental study. SETTING: Research laboratory at an academic medical center. SUBJECTS: The study enrolled 71 patients, 49 with septic shock and 22 with cardiogenic shock. Seventeen healthy controls served as reference. In vitro monocyte-derived dendritic cells were generated from healthy volunteers. INTERVENTIONS: Sera were assessed for their ability to promote in vitro dendritic cell death through flow cytometry detection in each group of patients. The percentage of apoptotic or necrotic dendritic cells was evaluated by annexin-V and propidium iodide staining. MEASUREMENTS AND MAIN RESULTS: We observed that only patients with septic shock and not patients with pure cardiogenic shock were characterized by a rapid and profound loss of circulating dendritic cells. In vitro analysis revealed that sera from patients with septic shock induced higher dendritic cell death compared to normal sera or cardiogenic shock (p<0.005). Sera from surviving patients induced dendritic cell death through a caspase-dependent apoptotic pathway, whereas sera from nonsurviving patients induced dendritic cell-regulated necrosis. Dendritic cell necrosis was not due to necroptosis but was dependent of the presence of circulating histone. The toxicity of histones toward dendritic cell could be prevented by recombinant human activated protein C. Finally, we observed a direct correlation between the levels of circulating histones in patients and the ability of the sera to promote dendritic cell-regulated necrosis. CONCLUSIONS: The study demonstrates a differential mechanism of dendritic cell death in patients with septic shock that is dependent on the severity of the disease.
Assuntos
Células Dendríticas/patologia , Histonas/sangue , Choque Séptico/sangue , Adulto , Idoso , Caspases/fisiologia , Morte Celular , Células Dendríticas/fisiologia , Feminino , Citometria de Fluxo , Histonas/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Necrose , Nucleossomos , Estudos Prospectivos , Choque Cardiogênico/sangue , Choque Séptico/mortalidadeRESUMO
OBJECTIVES: To investigate the outcome of patients with acute myocardial infarction (AMI) complicated by refractory cardiogenic shock (CS) who underwent mechanical circulatory support with Impella 2.5. BACKGROUND: AMI complicated by CS remains a highly fatal condition. A potent and minimally invasive left ventricular assist device might improve patient outcomes. METHODS: We analyzed the procedural characteristics and outcomes of 22 consecutive patients who underwent, between July 2008 and December 2012, a percutaneous coronary intervention and Impella 2.5 support for AMI complicated by CS refractory to first-line therapy with inotropes and/or Intra-aortic balloon pump. RESULTS: In this analysis, patients were relatively young with a mean age of 57.9 ± 11.6 year old and 59.1% were male. The majority of patients (77.3%) were admitted in CS and 40.9% sustained cardiac arrest prior to admission. Hemodynamics improved significantly upon initiation of support, end-organ and tissue perfusion improved subsequently demonstrated by a significant decrease in lactate levels from 6.37 ± 5.3 mmol/L to 2.41 ± 2.1 mmo/L, (P = 0.008) after 2 days of support. Thirteen (59.1%) patients were successfully weaned-off Impella 2.5 and 4 (18.2%) were transitioned to another device. We observed a functional recovery of the left ventricle when compared to baseline (43 ± 10% vs. 27 ± 9%, P < 0.0001). The survival rate at 6 months and 1 year was 59.1% and 54.5%, respectively. CONCLUSION: Impella 2.5 was initiated as a last resort therapy to support very sick patients with refractory CS after failed conventional therapy. The use of the device yielded favorable short and mid-term survival results with recovery being the most frequently observed outcome.
Assuntos
Coração Auxiliar , Infarto do Miocárdio/terapia , Choque Cardiogênico/complicações , Choque Cardiogênico/mortalidade , Circulação Sanguínea , Cardiotônicos/efeitos adversos , Feminino , França/epidemiologia , Hemodinâmica , Humanos , Balão Intra-Aórtico/efeitos adversos , Ácido Láctico/sangue , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/complicações , Infarto do Miocárdio/mortalidade , Intervenção Coronária Percutânea , Falha de TratamentoAssuntos
Antibacterianos/efeitos adversos , Autoanticorpos/imunologia , Doenças Autoimunes/terapia , Ceftriaxona/efeitos adversos , Deficiência do Fator V/terapia , Fator V/imunologia , Transfusão de Plaquetas , Cuidados Pré-Operatórios/métodos , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Antibacterianos/uso terapêutico , Anticoagulantes/uso terapêutico , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/cirurgia , Fibrilação Atrial/complicações , Fibrilação Atrial/tratamento farmacológico , Autoanticorpos/sangue , Doenças Autoimunes/diagnóstico , Doenças Autoimunes/imunologia , Ceftriaxona/uso terapêutico , Terapia Combinada , Emergências , Deficiência do Fator V/diagnóstico , Deficiência do Fator V/imunologia , Feminino , Insuficiência Cardíaca/etiologia , Humanos , Tempo de Tromboplastina Parcial , Prednisona/uso terapêutico , Tempo de Protrombina , Pirazóis/efeitos adversos , Pirazóis/uso terapêutico , Piridonas/efeitos adversos , Piridonas/uso terapêutico , Infecções Urinárias/complicações , Infecções Urinárias/tratamento farmacológicoRESUMO
Prasugrel is a widely used antiplatelet agent in the setting of percutaneous coronary intervention. In case of resistance to this third-generation thienopyridine, choices of alternative drugs remain limited. Here, we describe a case of a 49-year-old man with stent thrombosis occurring 5 days after drug-eluting stent implantation despite a well-conducted antiplatelet therapy with aspirin and prasugrel. Evaluation of platelet functions by different tests revealed prasugrel resistance. Genotyping for various CYP single-nucleotide polymorphisms showed that the patient carried mutant alleles encoding enzymes CYP2B6 and CYP2C9 involved in prasugrel metabolic pathway. Strikingly, an adequate platelet response was rapidly obtained after switching from prasugrel to ticagrelor.
Assuntos
Adenosina/análogos & derivados , Piperazinas/efeitos adversos , Antagonistas do Receptor Purinérgico P2Y/uso terapêutico , Tiofenos/efeitos adversos , Trombose/tratamento farmacológico , Adenosina/uso terapêutico , Resistência a Medicamentos , Humanos , Masculino , Pessoa de Meia-Idade , Cloridrato de Prasugrel , Trombose/etiologia , TicagrelorRESUMO
BACKGROUND: Large datasets of transcatheter aortic valve implantation (TAVI) for pure aortic valve regurgitation (PAVR) are scarce. AIMS: We aimed to report procedural safety and long-term clinical events (CE) in a contemporary cohort of PAVR patients treated with new-generation devices (NGD). METHODS: Patients with grade III/IV PAVR enrolled in the FRANCE-TAVI Registry were selected. The primary safety endpoint was technical success (TS) according to Valve Academic Research Consortium 3 criteria. The co-primary endpoint was defined as a composite of mortality, heart failure hospitalisation and valve reintervention at last follow-up. RESULTS: From 2015 to 2021, 227 individuals (64.3% males, median age 81.0 [interquartile range {IQR} 73.5-85.0] years, with EuroSCORE II 6.0% [IQR 4.0-10.9]) from 41 centres underwent TAVI with NGD, using either self-expanding (55.1%) or balloon-expandable valves (44.9%; p=0.50). TS was 85.5%, with a non-significant trend towards increased TS in high-volume activity centres. A second valve implantation (SVI) was needed in 8.8% of patients, independent of valve type (p=0.82). Device size was ≥29 mm in 73.0% of patients, post-procedure grade ≥III residual aortic regurgitation was rare (1.2%), and the permanent pacemaker implantation (PPI) rate was 36.0%. At 30 days, the incidences of mortality and reintervention were 8.4% and 3.5%, respectively. The co-primary endpoint reached 41.6% (IQR 34.4-49.6) at 1 year, increased up to 61.8% (IQR 52.4-71.2) at 4 years, and was independently predicted by TS, with a hazard ratio of 0.45 (95% confidence interval: 0.27-0.76); p=0.003. CONCLUSIONS: TAVI with NGD in PAVR patients is efficient and reasonably safe. Preventing the need for an SVI embodies the major technical challenge. Larger implanted valves may have limited this complication, outweighing the increased risk of PPI. Despite successful TAVI, PAVR patients experience frequent CE at long-term follow-up.
Assuntos
Insuficiência da Valva Aórtica , Próteses Valvulares Cardíacas , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Insuficiência da Valva Aórtica/cirurgia , Masculino , Feminino , Idoso , Idoso de 80 Anos ou mais , Resultado do Tratamento , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Fatores de Risco , FrançaRESUMO
BACKGROUND: Patients with mitral regurgitation (MR) and morphologic presence of relevant mitral annular calcification (MAC) represent a challenging phenotypic subset with limited treatment options. OBJECTIVES: The aim of this study was to assess the feasibility of transcatheter mitral valve replacement (TMVR) using dedicated devices for the treatment of MAC patients. METHODS: Consecutive patients with symptomatic MR receiving TMVR and with available computed tomography data from the CHOICE-MI (Choice of Optimal Transcatheter Treatment for Mitral Insufficiency) multicenter registry were stratified by the presence of none or mild mitral annular calcification (MACnone/mild) vs moderate or severe mitral annular calcification (MACmod/sev). RESULTS: Among 279 eligible patients (median age = 76.0 years [Q1-Q3: 71.0-81.0 years], EuroSCORE II = 6.2% [Q1-Q3: 3.9%-12.1%]), 222 (79.6%) presented with MACnone/mild and 57 (20.4%) with MACmod/sev. Patients with MACmod/sev had a higher prevalence of extracardiac arteriopathy (P = 0.011) and primary MR (P < 0.001). Although the technical success rate and the extent of MR elimination did not differ, TMVR treatment in MACmod/sev patients was associated with higher rates of postprocedural bleeding complications (P = 0.02) and renal failure (P < 0.001). Functional improvement at the 1- and 2-year follow-up did not differ between groups. At the 2-year follow-up, there were no differences between patients with MACmod/sev and MACnone/mild regarding all-cause mortality (38.5% vs 37.7%; P = 0.76), cardiovascular mortality (21.3% vs 24.9%; P = 0.97), and all-cause mortality or heart failure hospitalization (52.4% vs 46.7%; P = 0.28) CONCLUSIONS: TMVR in patients with MACmod/sev is associated with higher rates of postprocedural complications but similar rates of survival, MR resolution, and functional improvement compared to MACnone/mild. Further studies are necessary to define the role of dedicated TMVR devices in this population. (Choice of Optimal Transcatheter Treatment for Mitral Insufficiency Registry [CHOICE-MI]; NCT04688190).
Assuntos
Calcinose , Cateterismo Cardíaco , Estudos de Viabilidade , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Valva Mitral , Desenho de Prótese , Recuperação de Função Fisiológica , Sistema de Registros , Humanos , Idoso , Masculino , Feminino , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/mortalidade , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Valva Mitral/cirurgia , Resultado do Tratamento , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/mortalidade , Idoso de 80 Anos ou mais , Fatores de Tempo , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Calcinose/diagnóstico por imagem , Calcinose/cirurgia , Calcinose/mortalidade , Calcinose/fisiopatologia , Calcinose/terapia , Fatores de Risco , Índice de Gravidade de Doença , Europa (Continente)RESUMO
BACKGROUND: There are limited data on the impact of transcatheter heart valve (THV) type on the outcomes of surgical explantation after THV failure. AIMS: We sought to determine the outcomes of transcatheter aortic valve replacement (TAVR) explantation for failed balloon-expandable valves (BEV) versus self-expanding valves (SEV). METHODS: From November 2009 to February 2022, 401 patients across 42 centres in the EXPLANT-TAVR registry underwent TAVR explantation during a separate admission from the initial TAVR. Mechanically expandable valves (N=10, 2.5%) were excluded. The outcomes of TAVR explantation were compared for 202 (51.7%) failed BEV and 189 (48.3%) failed SEV. RESULTS: Among 391 patients analysed (mean age: 73.0±9.8 years; 33.8% female), the median time from index TAVR to TAVR explantation was 13.3 months (interquartile range 5.1-34.8), with no differences between groups. Indications for TAVR explantation included endocarditis (36.0% failed SEV vs 55.4% failed BEV; p<0.001), paravalvular leak (21.2% vs 11.9%; p=0.014), structural valve deterioration (30.2% vs 21.8%; p=0.065) and prosthesis-patient mismatch (8.5% vs 10.4%; p=0.61). The SEV group trended fewer urgent/emergency surgeries (52.0% vs 62.3%; p=0.057) and more root replacement (15.3% vs 7.4%; p=0.016). Concomitant cardiac procedures were performed in 57.8% of patients, including coronary artery bypass graft (24.8%), and mitral (38.9%) and tricuspid (14.6%) valve surgery, with no differences between groups. In-hospital, 30-day, and 1-year mortality and stroke rates were similar between groups (allp>0.05), with no differences in cumulative mortality at 3 years (log-rank p=0.95). On multivariable analysis, concomitant mitral surgery was an independent predictor of 1-year mortality after BEV explant (hazard ratio [HR] 2.00, 95% confidence interval [CI]: 1.07-3.72) and SEV explant (HR 2.00, 95% CI: 1.08-3.69). CONCLUSIONS: In the EXPLANT-TAVR global registry, BEV and SEV groups had different indications for surgical explantation, with more root replacements in SEV failure, but no differences in midterm mortality and morbidities. Further refinement of TAVR explantation techniques are important to improving outcomes.
Assuntos
Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Masculino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Remoção de Dispositivo , Catéteres , Valvas Cardíacas , Sistema de RegistrosRESUMO
Severe anaphylactoid reaction after the use of iodinated contrast media are rare but can contraindicate the use of contrast agent. It was the case of a 53-year-old woman suffering from symptomatic severe aortic stenosis, recused for cardiac surgery because of deleterious effects of chest-wall irradiation, with porcelain aorta. We decided to implant a 23-mm Edwards(®) SAPIEN(®) transcatheter aortic valve via a femoral route without using any contrast media. The implantation was successful after surgical approach of the femoral artery, transesophageal echocardiography guiding, and localization of native leaflets and coronary trunk with catheters. Immediate and one month post-interventional follow-up was favorable and echocardiography showed a good functioning of the aortic bioprosthesis. Although conventional angiography is the best way to visualize the good positioning of the valve before deployment, our case suggests that, in special situations, transfemoral implantation of an Edwards(®) SAPIEN(®) aortic bioprosthesis is feasible without any contrast injection.
Assuntos
Anafilaxia/induzido quimicamente , Estenose da Valva Aórtica/terapia , Bioprótese , Cateterismo Cardíaco , Meios de Contraste/efeitos adversos , Hipersensibilidade a Drogas/etiologia , Artéria Femoral , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Anafilaxia/prevenção & controle , Estenose da Valva Aórtica/diagnóstico , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/métodos , Hipersensibilidade a Drogas/prevenção & controle , Ecocardiografia Transesofagiana , Feminino , Artéria Femoral/diagnóstico por imagem , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Desenho de Prótese , Índice de Gravidade de Doença , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Ultrassonografia de Intervenção/métodosRESUMO
A 75-year-old female patient was referred to our institution for severe symptomatic low-flow low-gradient aortic valve stenosis and tricuspid valve regurgitation (TR) associated with heart failure. After multidisciplinary discussion, the patient was scheduled for one-stage totally percutaneous treatment of her valve lesions by transcatheter aortic valve implantation (TAVI) and transcatheter edge-to-edge tricuspid valve repair (TEER) through transfemoral access. The patient had an uneventful hospital stay and was discharged home on the third postoperative day. During the following 24 months, the patient did well with regression of her heart failure signs and symptoms.
RESUMO
Tricuspid regurgitation is a frequent condition that is linked to an elevated risk of cardiovascular events and significant mortality but is often overshadowed by left-sided valve diseases. Isolated surgical tricuspid valve surgery is still considered a high-risk surgery, and over recent years, various transcatheter procedures for tricuspid treatment have emerged as an alternative solution. Among the available transcatheter procedures, the EVOQUE system's transcatheter tricuspid valve replacement could potentially offer a solution, especially in patients considered non-eligible for transcatheter edge-to-edge tricuspid valve repair. We present a case report of an octogenarian patient considered at prohibitive risk for conventional surgery and not eligible for transcatheter edge-to-edge repair who was eventually treated with a transfemoral transcatheter tricuspid 52-mm EVOQUE valve implantation. Postprocedural recovery and follow-up at 18 months were uneventful, with a well-functioning tricuspid valve bioprosthesis.
RESUMO
OBJECTIVES: The aim of this study was to investigate the impact of Valve Academic Research Consortium 3 minor access site vascular complications (VCs) in patients who underwent percutaneous transfemoral (TF) transcatheter aortic valve implantation (TAVI). METHODS: This single-centre retrospective study included consecutive patients who underwent percutaneous TF-TAVI from 2009 to 2021. A propensity score-matched analysis was performed to compare early and long-term clinical results between patients with VC and without VC (nVC). RESULTS: A total of 2161 patients were included, of whom 284 (13.1%) experienced access site VC. Propensity score analysis allowed to match 270 patients from the VC group with 727 patients from the nVC group. In the matched cohorts, the VC group showed longer operative times (63.5 vs 50.0 min, P < 0.001), higher operative and in-hospital mortality (2.6% vs 0.7%, P = 0.022; and 6.3% vs 3.2%, P = 0.040, respectively), longer hospital length of stay (8 vs 7 days, P = 0.001) and higher rates of blood transfusion (20.4% vs 4.3%, P < 0.001) and infectious complications (8.9% vs 3.8%, P = 0.003). Overall survival during follow-up was significantly lower in the VC group (hazard ratio 1.37, 95% CI 1.03-1.82, P = 0.031) with 5-year survival rates being 58.0% (95% CI 49.5-68.0%) and 70.7% (95% CI 66.2-75.5%) for the VC and nVC groups, respectively. CONCLUSIONS: This retrospective study observed that minor access site VCs during percutaneous TF-TAVI can be serious events affecting early and long-term outcomes.
Assuntos
Estenose da Valva Aórtica , Doenças Cardiovasculares , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Estudos Retrospectivos , Resultado do Tratamento , Doenças Cardiovasculares/cirurgia , Valva Aórtica/cirurgia , Artéria Femoral/cirurgiaRESUMO
We developed humanized biosimulator to predict the risk of coronary obstruction among high-risk patients undergoing valve-in-valve (ViV) procedures. In this case, based on unchanged instantaneous wave-free ratio values measured during a ViV simulation session, the procedure was performed safely in the patient the day afterward, without coronary artery issues and with good hemodynamic results. (Level of Difficulty: Advanced.).
RESUMO
Structural heart interventions are steadily increasing, and the majority requires echocardiographic guidance. As a result, imaging specialists are exposed to the harmful effects of scattered ionizing radiation. This X-ray exposure must be quantified, its potential consequences should be monitored by occupational medicine and the "as low as reasonably achievable" principles of radioprotection should be optimized (including increasing the distance, decreasing the duration, using shielding radiation and providing safety training for the imaging specialist). The spatial organization of and shielding provision in the procedural rooms should be designed to optimize radioprotection for all team members.