Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Stroke ; 54(3): 751-758, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36748463

RESUMO

BACKGROUND: Collateral formation from the extracranial carotid artery to ischemic brain tissue determines the clinical success of superficial temporal artery (STA) to middle cerebral artery (MCA) bypass surgery in adult patients with moyamoya disease, but postoperative collateral formation (PCF) after STA-MCA bypass surgery is unpredictable. Accurate preoperative prediction of acceptable PCF could improve patient selection. This study aims to develop a prediction nomogram model for PCF in this patient population. METHODS: Adult patients with moyamoya disease undergoing the STA-MCA bypass surgery between January 2013 and December 2020 at a single institution were retrospectively or prospectively enrolled in this observational study. Data including potential clinical and radiological predictors were obtained from hospital records. A nomogram was generated based on a multivariate logistic regression analysis, to identify potential predictors associated with good PCF. The performance of the nomogram was evaluated for discrimination, calibration, and clinical utility. RESULTS: Data from 243 patients with moyamoya disease who underwent the STA-MCA bypass surgery were analyzed to build the nomogram. After 1-year follow-up, 162 (66.7%) hemispheres had good PCF and 81 (33.3%) had poor PCF. Good PCF is associated with 3 preoperative factors: age at operation, a diameter of donor branch of STA, and the preinfarction period stage. Incorporating these 3 factors, the model achieved a concordance index of 0.88 (95% CI, 0.84-0.92) and had a well-fitted calibration curve and good clinical application value. A cutoff value of 100 was determined to predict good PCF via this nomogram. CONCLUSIONS: The nomogram exhibits high accuracy in predicting good PCF after the STA-MCA bypass surgery in adult patients with moyamoya disease and may allow surgeons to better evaluate preoperatively candidacy for successful bypass surgery.


Assuntos
Revascularização Cerebral , Doença de Moyamoya , Humanos , Adulto , Doença de Moyamoya/diagnóstico por imagem , Doença de Moyamoya/cirurgia , Doença de Moyamoya/complicações , Artéria Cerebral Média/diagnóstico por imagem , Artéria Cerebral Média/cirurgia , Artérias Temporais/cirurgia , Estudos Retrospectivos , Nomogramas
2.
J Magn Reson Imaging ; 58(5): 1521-1530, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-36847756

RESUMO

BACKGROUND: The clinical application of coronary MR angiography (MRA) remains limited due to its long acquisition time and often unsatisfactory image quality. A compressed sensing artificial intelligence (CSAI) framework was recently introduced to overcome these limitations, but its feasibility in coronary MRA is unknown. PURPOSE: To evaluate the diagnostic performance of noncontrast-enhanced coronary MRA with CSAI in patients with suspected coronary artery disease (CAD). STUDY TYPE: Prospective observational study. POPULATION: A total of 64 consecutive patients (mean age ± standard deviation [SD]: 59 ± 10 years, 48.4% females) with suspected CAD. FIELD STRENGTH/SEQUENCE: A 3.0-T, balanced steady-state free precession sequence. ASSESSMENT: Three observers evaluated the image quality for 15 coronary segments of the right and left coronary arteries using a 5-point scoring system (1 = not visible; 5 = excellent). Image scores ≥3 were considered diagnostic. Furthermore, the detection of CAD with ≥50% stenosis was evaluated in comparison to reference standard coronary computed tomography angiography (CTA). Mean acquisition times for CSAI-based coronary MRA were measured. STATISTICAL TESTS: For each patient, vessel and segment, sensitivity, specificity, and diagnostic accuracy of CSAI-based coronary MRA for detecting CAD with ≥50% stenosis according to coronary CTA were calculated. Intraclass correlation coefficients (ICCs) were used to assess the interobserver agreement. RESULTS: The mean MR acquisition time ± SD was 8.1 ± 2.4 minutes. Twenty-five (39.1%) patients had CAD with ≥50% stenosis on coronary CTA and 29 (45.3%) patients on MRA. A total of 885 segments on the CTA images and 818/885 (92.4%) coronary MRA segments were diagnostic (image score ≥3). The sensitivity, specificity, and diagnostic accuracy were as follows: per patient (92.0%, 84.6%, and 87.5%), per vessel (82.9%, 93.4%, and 91.1%), and per segment (77.6%, 98.2%, and 96.6%), respectively. The ICCs for image quality and stenosis assessment were 0.76-0.99 and 0.66-1.00, respectively. DATA CONCLUSION: The image quality and diagnostic performance of coronary MRA with CSAI may show good results in comparison to coronary CTA in patients with suspected CAD. EVIDENCE LEVEL: 1. TECHNICAL EFFICACY: 2.


Assuntos
Doença da Artéria Coronariana , Aprendizado Profundo , Feminino , Humanos , Masculino , Doença da Artéria Coronariana/diagnóstico por imagem , Angiografia por Ressonância Magnética/métodos , Constrição Patológica , Inteligência Artificial , Angiografia Coronária , Sensibilidade e Especificidade
3.
Eur Radiol ; 33(11): 8180-8190, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37209126

RESUMO

OBJECTIVES: To examine a compressed sensing artificial intelligence (CSAI) framework to accelerate image acquisition in non-contrast-enhanced whole-heart bSSFP coronary magnetic resonance (MR) angiography. METHODS: Thirty healthy volunteers and 20 patients with suspected coronary artery disease (CAD) scheduled for coronary computed tomography angiography (CCTA) were enrolled. Non-contrast-enhanced coronary MR angiography was performed with CSAI, compressed sensing (CS), and sensitivity encoding (SENSE) methods in healthy participants and with CSAI in patients. Acquisition time, subjective image quality score, and objective image quality measurement (blood pool homogeneity, signal-to-noise ratio [SNR], and contrast-to-noise ratio [CNR]) were compared among the three protocols. The diagnostic performance of CASI coronary MR angiography for predicting significant stenosis (≥ 50% diameter stenosis) on CCTA was evaluated. The Friedman test was performed to compare the three protocols. RESULTS: Acquisition time was significantly shorter in the CSAI and CS groups than in the SENSE group (10.2 ± 3.2 min vs. 10.9 ± 2.9 min vs. 13.0 ± 4.1 min, p < 0.001). However, the CSAI approach had the highest image quality scores, blood pool homogeneity, mean SNR value, and mean CNR value (all p < 0.001) compared with the CS and SENSE approaches. The sensitivity, specificity, and accuracy of CSAI coronary MR angiography per patient were 87.5% (7/8), 91.7% (11/12), and 90.0% (18/20); those per vessel were 81.8% (9/11), 93.9% (46/49), and 91.7% (55/60); and those per segment were 84.6% (11/13), 98.0% (244/249), and 97.3% (255/262), respectively. CONCLUSIONS: CSAI yielded superior image quality within a clinically feasible acquisition time in healthy participants and patients with suspected CAD. CLINICAL RELEVANCE STATEMENT: The non-invasive and radiation-free CSAI framework could be a promising tool for rapid screening and comprehensive examination of the coronary vasculature in patients with suspected CAD. KEY POINTS: • This prospective study showed that CSAI enables a reduction in acquisition time by 22% with superior diagnostic image quality compared with the SENSE protocol. • CSAI replaces the wavelet transform with a CNN as a sparsifying transform in the CS algorithm, achieving high coronary MR image quality with reduced noise. • CSAI achieved per-patient sensitivity of 87.5% (7/8) and specificity of 91.7% (11/12) respectively for detecting significant coronary stenosis.


Assuntos
Doença da Artéria Coronariana , Aprendizado Profundo , Humanos , Angiografia Coronária/métodos , Estudos Prospectivos , Constrição Patológica , Estudos de Viabilidade , Inteligência Artificial , Doença da Artéria Coronariana/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/métodos , Angiografia por Ressonância Magnética/métodos
4.
Acta Radiol ; 64(6): 2211-2216, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37128160

RESUMO

BACKGROUND: Central catheter-related thrombosis (CRT) is the most common catheter-related complication in patients with end-stage renal disease (ESRD) but is often underappreciated and misdiagnosed by radiologist. PURPOSE: To find the computed tomography angiography (CTA) characteristics of central CRT, then raise the diagnosis of this disorder. MATERIAL AND METHODS: A total of 301 eligible patients with ESRD who experienced both chest multi-phase multidetector CTA (MDCTA) and digital subtraction angiography were enrolled in the final analysis. The location, shape, and related signs of the central CRT in MDCTA images were evaluated. Independent-samples T test, chi-square test, and binary logistic regression were analyzed using SPSS software. RESULTS: In total, 166 patients were found to have CRT using MDCTA, and this was verified by DSA. Central CRT was usually irregular in the superior vena cava segment, and the angle of the contact area between central CRT and catheter was <180° (all P < 0.05). Age, collateral circulation, and venous stenosis were shown to have significant differences when compared to patients without CRT (all P < 0.05), but there were no significant differences about the sex or catheter insertion site. In addition, age and collateral circulation were the factors found to be significantly associated with thrombosis (P < 0.05). In particular, the thrombosis was 2.213 times more likely to be found in those patients with collateral circulation (odds ratio = 2.213, 95% confidence interval = 1.236-3.961). CONCLUSION: Chest multi-phase MDCTA can effectively reduce the missed diagnosis and misdiagnosis of central CRT. It is worth paying more attention to the central CRT especially when the collateral circulation is observed.


Assuntos
Cateteres Venosos Centrais , Falência Renal Crônica , Trombose , Trombose Venosa , Humanos , Angiografia por Tomografia Computadorizada , Veia Cava Superior , Trombose/etiologia , Trombose Venosa/diagnóstico por imagem , Falência Renal Crônica/complicações , Falência Renal Crônica/terapia , Diálise Renal/efeitos adversos , Angiografia Digital , Tomografia Computadorizada Multidetectores , Catéteres/efeitos adversos , Cateteres Venosos Centrais/efeitos adversos
5.
Stroke ; 53(1): 210-217, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34547926

RESUMO

BACKGROUND AND PURPOSE: There is also a risk of stroke in the asymptomatic hemispheres of moyamoya disease (MMD), but it does not draw enough attention. The study investigated the differences between the three types of asymptomatic hemispheres in MMD and their associations with the two types of symptomatic hemispheres, respectively. METHODS: Retrospectively reviewed clinical and imaging characteristics of asymptomatic and symptomatic hemispheres in consecutive cases of single-center MMD patients, with an emphasis on imaging characterization regarding vascular morphology and cerebral perfusion. MMD hemispheres were categorized into 5 types: hemorrhagic hemispheres, ischemic hemispheres, asymptomatic hemispheres in unilateral hemorrhagic MMD, asymptomatic hemispheres in unilateral ischemic MMD, and bilateral asymptomatic hemispheres in MMD. Angiographic feature was assessed by Suzuki's angiographic stage, while hemodynamic feature was assessed by preinfarction period stage. RESULTS: One hundred ninety-four MMD patients with 388 hemispheres were enrolled. Asymptomatic hemispheres in unilateral hemorrhagic MMD were largely similar to hemorrhagic hemispheres, both had more advanced Suzuki's angiographic stage and lower degree of hemodynamic failure compared with bilateral asymptomatic hemispheres in MMD and asymptomatic hemispheres in unilateral ischemic MMD. Asymptomatic hemispheres in unilateral ischemic MMD were similar to ischemic hemispheres, both had less advanced Suzuki's angiographic stage and higher degree of hemodynamic failure compared with bilateral asymptomatic hemispheres in MMD and asymptomatic hemispheres in unilateral hemorrhagic MMD. Bilateral asymptomatic hemispheres in MMD were different from the other hemispheres and had less advanced Suzuki's angiographic stage and lower degree of hemodynamic failure. CONCLUSIONS: The three types of asymptomatic hemispheres in MMD are defined and have unique angiographic and hemodynamic features. Different combinations of the two features can reflect the tendency of pathological evolution in these different asymptomatic hemispheres.


Assuntos
Doenças Assintomáticas , Encéfalo/diagnóstico por imagem , Angiografia Cerebral/métodos , Circulação Cerebrovascular/fisiologia , Hemodinâmica/fisiologia , Doença de Moyamoya/diagnóstico por imagem , Adolescente , Adulto , Idoso , Encéfalo/fisiopatologia , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doença de Moyamoya/fisiopatologia , Estudos Retrospectivos , Adulto Jovem
6.
Respir Res ; 23(1): 47, 2022 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-35248040

RESUMO

BACKGROUND: High-resolution computed tomography (HRCT) is recommended diagnosing and monitoring connective tissue disease-associated interstitial lung disease (CTD-ILD). Quantitative computed tomography has the potential to precisely assess the radiological severity of CTD-ILD, but has still been under study. OBJECTIVE: To investigate whether dual-energy computed tomography (DECT), a novel quantitative technique, can be used for quantitative severity assessment in CTD-ILD. METHODS: This cross sectional study recruited adult CTD-ILD patients who underwent DECT scans from the ICE study between October 2019 and November 2021. DECT parameters, including effective atomic number (Zeff), lung (lobe) volume, and monochromatic CT number (MCTN) of each lung lobe, were evaluated. CTD-ILD was classified into extensive CTD-ILD and limited CTD-ILD by staging algorithm using combined forced vital capacity (FVC)%predicted and total extent of ILD (TEI) on CT. Dyspnea, cough, and life quality were scored by Borg dyspnea score, Leicester cough questionnaire (LCQ), and short-form 36 health survey questionnaire (SF-36), respectively. RESULTS: There was a total of 147 patients with DECT scans enrolled. Higher Zeff value (3.104 vs 2.256, p < 0.001), higher MCTN (- 722.87 HU vs - 802.20 HU, p < 0.001), and lower lung volume (2309.51cm3 vs 3475.21cm3, p < 0.001) were found in extensive CTD-ILD compared with limited CTD-ILD. DECT parameters had significant moderate correlations with FVC%predicted (|r|= 0.542-0.667, p < 0.01), DLCO%predicted (|r|= 0.371-0.427, p < 0.01), and TEI (|r|= 0.485-0.742, p < 0.01). Receiver operating characteristic (ROC) analysis indicated MCTN averaged over the whole lung had the best performance for extensive CTD-ILD discrimination (AUC = 0.901, cut-off: - 762.30 HU, p < 0.001), with a sensitivity of 82.1% and a specificity of 85.4%. The Zeff value was the independent risk factor for dyspnea (OR = 3.644, 95% CI: 1.846-7.192, p < 0.001) and cough (OR = 3.101, 95% CI: 1.528-6.294, p = 0.002), and lung volume significantly contributed to the mental component summary (MCS) in SF-36 (standardized ß = 0.198, p < 0.05). CONCLUSIONS: DECT can be applied to evaluate the severity of CTD-ILD.


Assuntos
Doenças Pulmonares Intersticiais/diagnóstico , Pulmão/diagnóstico por imagem , Qualidade de Vida , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Capacidade Vital/fisiologia , Estudos Transversais , Feminino , Humanos , Pulmão/fisiopatologia , Doenças Pulmonares Intersticiais/fisiopatologia , Masculino , Pessoa de Meia-Idade , Curva ROC , Índice de Gravidade de Doença
7.
Eur Radiol ; 32(5): 2912-2920, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35059803

RESUMO

OBJECTIVES: To explore the use of 70-kVp tube voltage combined with high-strength deep learning image reconstruction (DLIR-H) in reducing radiation and contrast doses in coronary CT angiography (CCTA) in patients with body mass index (BMI) < 26 kg/m2, in comparison with the conventional scan protocol using 120 kVp and adaptive statistical iterative reconstruction (ASIR-V). METHODS: A total of 100 patients referred to CCTA were prospectively enrolled and randomly divided into two groups: low-dose group (n = 50) with 70 kVp, Smart mA for noise index (NI) of 36HU, contrast dose rate of 16mgI/kg/s, and DLIR-H, and conventional group (n = 50) with 120 kV, Smart mA for NI of 25HU, contrast dose rate of 32mgI/kg/s, and 60%ASIR-V. Radiation and contrast dose, subjective image quality score, and objective image quality measurement (image noise, contrast-noise-ratio (CNR), and signal-noise-ratio (SNR) for vessel) were compared between the two groups. RESULTS: Low-dose group used significantly reduced contrast dose (23.82 ± 3.69 mL, 50.6% reduction) and radiation dose (0.75 ± 0.14 mSv, 54.5% reduction) compared to the conventional group (48.23 ± 6.38 mL and 1.65 ± 0.66 mSv, respectively) (all p < 0.001). Both groups had similar enhancement in vessels. However, the low-dose group had lower background noise (23.57 ± 4.74 HU vs. 35.04 ± 8.41 HU), higher CNR in RCA (48.63 ± 10.76 vs. 29.32 ± 5.52), LAD (47.33 ± 10.20 vs. 29.27 ± 5.12), and LCX (46.74 ± 9.76 vs. 28.58 ± 5.12) (all p < 0.001) compared to the conventional group. CONCLUSIONS: The use of 70-kVp tube voltage combined with DLIR-H for CCTA in normal size patients significantly reduces radiation dose and contrast dose while further improving image quality compared with the conventional 120-kVp tube voltage with 60%ASIR-V. KEY POINTS: • The combination of 70-kVp tube voltage and high-strength deep learning image reconstruction (DLIR-H) algorithm protocol reduces approximately 50% of radiation and contrast doses in coronary computed tomography angiography (CCTA) compared with the conventional scan protocol. • CCTA of normal size (BMI < 26 kg/m2) patients acquired at sub-mSv radiation dose and 24 mL contrast dose through the combination of 70-kVp tube voltage and DLIR-H algorithm achieves excellent diagnostic image quality with a good inter-rater agreement. • DLIR-H algorithm shows a higher capacity of significantly reducing image noise than adaptive statistical iterative reconstruction algorithm in CCTA examination.


Assuntos
Angiografia por Tomografia Computadorizada , Aprendizado Profundo , Algoritmos , Angiografia por Tomografia Computadorizada/métodos , Meios de Contraste , Angiografia Coronária/métodos , Humanos , Processamento de Imagem Assistida por Computador , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos
8.
Sichuan Da Xue Xue Bao Yi Xue Ban ; 53(4): 676-681, 2022 Jul.
Artigo em Zh | MEDLINE | ID: mdl-35871740

RESUMO

Objective: To explore the application value of the "three-low" technique (low radiation dose, low contrast agent dosage and low contrast agent flow rate) combined with artificial intelligence iterative reconstruction (AIIR) in aortic CT angiography (CTA). Methods: A total of 33 patients who underwent aortic CTA were prospectively enrolled. Based on the time of their follow-up examinations, the imaging data were divided into Group A and Group B, with Group A being the control group (100 kV, 0.8 mL/kg, 5 mL/s) and Group B being the "three-low" technique group (70 kV, 0.5 mL/kg, 3 mL/s). In group A, the images were reconstructed by Karl iterative algorithm. Group B was divided into B1 and B2 subgroups, with their images being reconstructed by Karl iterative algorithm and AIIR, respectively. The CT and SD values of the ascending aorta, descending aorta, abdominal aorta, left common iliac artery and right common iliac artery were measured, and the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. The subjective scoring of image quality was performed. The radiation dose parameters were documented. Results: Differences in the CT value, SD value, SNR and CNR of the three groups were statistically significant ( P<0.001). The CT value, SNR and CNR of group B2 were significantly higher than those of group B1, while the SD value of group B2 was significantly lower than that of group B1 ( P<0.017). There was no significant difference between the CT values of group A and those of group B2 ( P>0.017). The SD values, SNR and CNR in group B2 were better than those in group A ( P>0.017). There was significant difference in the subjective evaluation of image quality among the three groups ( P<0.05), but there was no significant difference between group A and group B2 ( P>0.017). The radiation dose and contrast medium dosage in group B decreased 84.14% and 37.08%, respectively, compared with those of group A. Conclusion: With the "three-low" technique combined with AIIR algorithm, the image quality of aortic CTA obtained is comparable to that of conventional dose scanning, while the radiation dose, contrast agent dosage and contrast agent flow rate of patients are significantly reduced.


Assuntos
Inteligência Artificial , Angiografia por Tomografia Computadorizada , Algoritmos , Aorta/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/métodos , Meios de Contraste , Humanos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador , Tomografia Computadorizada por Raios X
9.
J Neuroradiol ; 44(5): 313-318, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28237366

RESUMO

BACKGROUND AND PURPOSE: It has been acknowledged that delayed cerebral ischemia (DCI) after aneurysmal subarachnoid hemorrhage (SAH) can be diagnosed by CT perfusion (CTP) in the DCI time-window. We evaluated the diagnostic accuracy of CTP for DCI during the early stage of the time-window. MATERIALS AND METHODS: We prospectively enrolled patients with aneurysmal SAH. DCI was defined as both new cerebral infarction and clinical deterioration after SAH. CTP was performed by using a standardized protocol with predefined regions of interest in 4 to 6 days after SAH. We quantitatively evaluated the diagnostic accuracy of eight CTP parameters (4 for absolute parameters and 4 for relative parameters). The receiver operator characteristic (ROC) curves of all parameters were generated and the optimal threshold values were derived for the calculation of sensitivities and specificities. RESULTS: Fifty-three patients were enrolled and 20 patients were diagnosed with DCI. In the analysis of absolute CTP parameters, CBF and MTT had areas under the curve (AUC) >0.75 and the optimal threshold value was 40.4mL/100g/min and 3.78seconds, respectively. Through the evaluation of relative CTP parameters, all 4 parameters had AUC >0.75 and the optimal threshold value was 0.9 for CBV ratio, 0.85 for CBF ratio, 0.32seconds for MTT difference and 1.31seconds for TTP difference. CONCLUSIONS: Besides two absolute CTP parameters (CBV and TTP), all six CTP parameters can be used as good diagnostic tests for DCI in the early stage of the time-window.


Assuntos
Isquemia Encefálica/diagnóstico por imagem , Hemorragia Subaracnóidea/diagnóstico por imagem , Angiografia Digital , Isquemia Encefálica/etiologia , Angiografia Cerebral , Circulação Cerebrovascular , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Interpretação de Imagem Radiográfica Assistida por Computador , Fatores de Risco , Sensibilidade e Especificidade , Hemorragia Subaracnóidea/complicações , Fatores de Tempo
10.
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi ; 33(5): 945-50, 2016 Oct.
Artigo em Zh | MEDLINE | ID: mdl-29714949

RESUMO

The purpose of this study was to explore the feasibility of dual-source computed tomography(DSCT)highpitch scan mode in the preoperative evaluation of severe aortic stenosis(AS)referred to transcatheter aortic valve implantation(TAVI).Thirty patients with severe AS referred for TAVI underwent cervico-femoral artery joint DSCT angiography.Measurement and calculation of contrast,contrast noise ratio(CNR)and noise of aorta and access vessels were performed.The intra-and inter-observer reproducibilities for assessing aortic root and access vessels were evaluated.Evaluation of shape and plagues of aorta and access vessels was performed.The contrast,CNR and noise of aorta and access vessels were 348.2~457.9HU,12.2~30.3HU and 19.1~48.1 HU,respectively.There were good intra-and inter-observer reproducibilities in assessing aortic root and access vessels by DSCT(mean difference:-0.73~0.79 mm,r=0.90~0.98,P<0.001;mean difference:-0.70~0.73 mm,r=0.90~0.96,P<0.001).In the 30 patients,the diameters of external iliac artery,femeral artery or subclavian artery were less than 7mm in 5cases(16.7%),marked calcification in bilateral common iliac arteries in 1case(3.3%)and marked soft plaque in left common iliac artery in 1case(3.3%).DSCT high-pitch scan mode was feasible in the preoperative evaluation of aorta and access vessels in patients with AS referred for TAVI.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Substituição da Valva Aórtica Transcateter , Angiografia , Aorta/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Meios de Contraste , Estudos de Viabilidade , Artéria Femoral , Próteses Valvulares Cardíacas , Humanos , Artéria Ilíaca/diagnóstico por imagem , Tomografia Computadorizada Multidetectores , Cintilografia , Tomografia Computadorizada por Raios X
11.
ACS Appl Mater Interfaces ; 16(25): 32727-32738, 2024 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-38864718

RESUMO

Enhancing the sensitivity of capacitive pressure sensors through microstructure design may compromise the reliability of the device and rely on intricate manufacturing processes. It is an effective way to solve this issue by balancing the intrinsic properties (elastic modulus and dielectric constant) of the dielectric layer materials. Here, we introduce a liquid metal (LM) hybrid elastomer prepared by a chain-extension-free polyurethane (PU) and LM. The synergistic strategies of extender-free and LM doping effectively reduce the elastic modulus (7.6 ± 0.2-2.1 ± 0.3 MPa) and enhance the dielectric constant (5.12-8.17 @1 kHz) of LM hybrid elastomers. Interestingly, the LM hybrid elastomer combines reprocessability, recyclability, and photothermal conversion. The obtained flexible pressure sensor can be used for detecting hand and throat muscle movements, and high-precision speech recognition of seven words has been using a convolutional neural network (CNN) in deep learning. This work provides an idea for designing and manufacturing wearable, recyclable, and intelligent control pressure sensors.

12.
Nanomaterials (Basel) ; 14(15)2024 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-39120417

RESUMO

The activation of PMS to produce active species is an attractive technique for antibiotic degradation but is restricted to the low reaction kinetics and high costs. In this work, a cobalt-based catalyst was prepared by in situ electrodeposition to enhance the electrically activated PMS process for the degradation of antibiotics. Almost 100% of pefloxacin (PFX) was removed within 10 min by employing Co(OH)2 as the catalyst in the electrically activated peroxymonosulfate (PMS) process, and the reaction kinetic constant reached 0.52 min-1. The redox processes of Co2+ and Co3+ in Co(OH)2 catalysts were considered to be the main pathways for PMS activation, in which 1O2 was the main active species. Furthermore, this strategy could also achieve excellent degradation efficiency for other organic pollutants. This study provides an effective and low-cost strategy with no secondary pollution for pollutant degradation.

13.
Water Res ; 262: 122104, 2024 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-39032331

RESUMO

Electrochemically active biofilms (EABs) play an ever-growingly critical role in the biological treatment of wastewater due to its low carbon footprint and sustainability. However, how the multispecies biofilms adapt, survive and become tolerant under acute and chronic toxicity such as antibiotic stress still remains well un-recognized. Here, the stress responses of EABs to tetracycline concentrations (CTC) and different operation schemes were comprehensively investigated. Results show that EABs can quickly adapt (start-up time is barely affected) to low CTC (≤ 5 µM) exposure while the adaptation time of EABs increases and the bioelectrocatalytic activity decreases at CTC ≥ 10 µM. EABs exhibit a good resilience and high anti-shocking capacity under chronic and acute TC stress, respectively. But chronic effects negatively affect the metabolic activity and extracellular electron transfer, and simultaneously change the spatial morphology and microbial community structure of EABs. Particularly, the typical exoelectrogens Geobacter anodireducens can be selectively enriched under chronic TC stress with relative abundance increasing from 45.11% to 85.96%, showing stronger TC tolerance than methanogens. This may be attributed to the effective survival strategies of EABs in response to TC stress, including antibiotic efflux regulated by tet(C) at the molecular level and the secretion of more extracellular proteins in the macro scale, as the C=O bond in amide I of aromatic amino acids plays a critical role in alleviating the damage of TC to cells. Overall, this study highlights the versatile defences of EABs in terms of microbial adaptation, survival strategies, and antibiotic resistance, and deepens the understanding of microbial communities' evolution of EABs in response to acute and chronic TC stress.


Assuntos
Biofilmes , Biofilmes/efeitos dos fármacos , Antibacterianos/farmacologia , Resistência Microbiana a Medicamentos , Adaptação Fisiológica , Tetraciclina/farmacologia
14.
World Neurosurg ; 181: e1012-e1018, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37952879

RESUMO

BACKGROUND: Moyamoya disease (MMD) cannot be found commonly as a rare type compared with other vascular disease, such as aneurysm. However, it cannot be ignored for its high fatality and disability rates. In addition, exact pathogenesis study of this disease is still on the way. The ivy sign is always observed in MMD, but the clinical importance of this sign in MMD isn't clearly known. The main purpose of this research was to specifically investigate the clinical significance. METHODS: In this retrospective cohort study to gather the baseline clinical and imaging study, the patients with MMD were hospitalized from January 2016 to 2020. In the analysis, univariate and multivariate logistic regression was used to testify whether ivy sign was independently associated with MMD characteristics including cerebrovascular morphology, cerebral hemodynamics, cerebrovascular events, and postoperative collateral formation (PCF). RESULTS: We included 156 patients with 312 hemispheres. As for the result of multivariate logistic regression analysis, we could discover a fact that ivy sign was tightly connected to the Suzuki stage ≥IV (odds ratio [OR], 1.386; 95% confidence interval [CI], 1.055-1.822; P = 0.019), cerebral blood flow (CBF) decreased type (OR, 2.330; 95% CI, 1.733-3.133; P = 0.000), age acted as a protective factor for CBF (OR, 0.966; 95% CI, 0.946-0.986; P = 0.001), the elder was more likely associated with decreased CBF. Ivy sign also played a significant role in ischemic cerebrovascular events (OR, 5.653; 95% CI, 3.092-10.336; P = 0.003), their remarkable connection could be seen on the study. We could also find that ivy sign was closely connected to the good PCF (OR, 2.830; 95% CI, 1.329-6.027; P = 0.007), and we couldn't ignore the fact that age was associated with good PCF as well (OR, 0.933; 95% CI, 0.882-0.987; P = 0.015). DISCUSSION: We could be more aware of the connection between ivy sign and Moyamoya disease from this study in order to implement diagnosis, treatment, and prognosis more efficiently.


Assuntos
Doença de Moyamoya , Humanos , Doença de Moyamoya/diagnóstico por imagem , Doença de Moyamoya/complicações , Imageamento por Ressonância Magnética/métodos , Estudos Retrospectivos , Prognóstico , Circulação Cerebrovascular/fisiologia
15.
J Imaging Inform Med ; 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38502435

RESUMO

This study aims to investigate the maximum achievable dose reduction for applying a new deep learning-based reconstruction algorithm, namely the artificial intelligence iterative reconstruction (AIIR), in computed tomography (CT) for hepatic lesion detection. A total of 40 patients with 98 clinically confirmed hepatic lesions were retrospectively included. The mean volume CT dose index was 13.66 ± 1.73 mGy in routine-dose portal venous CT examinations, where the images were originally obtained with hybrid iterative reconstruction (HIR). Low-dose simulations were performed in projection domain for 40%-, 20%-, and 10%-dose levels, followed by reconstruction using both HIR and AIIR. Two radiologists were asked to detect hepatic lesion on each set of low-dose image in separate sessions. Qualitative metrics including lesion conspicuity, diagnostic confidence, and overall image quality were evaluated using a 5-point scale. The contrast-to-noise ratio (CNR) for lesion was also calculated for quantitative assessment. The lesion CNR on AIIR at reduced doses were significantly higher than that on routine-dose HIR (all p < 0.05). Lower qualitative image quality was observed as the radiation dose reduced, while there were no significant differences between 40%-dose AIIR and routine-dose HIR images. The lesion detection rate was 100%, 98% (96/98), and 73.5% (72/98) on 40%-, 20%-, and 10%-dose AIIR, respectively, whereas it was 98% (96/98), 73.5% (72/98), and 40% (39/98) on the corresponding low-dose HIR, respectively. AIIR outperformed HIR in simulated low-dose CT examinations of the liver. The use of AIIR allows up to 60% dose reduction for lesion detection while maintaining comparable image quality to routine-dose HIR.

16.
Bioresour Technol ; 406: 131026, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38917910

RESUMO

A bioelectrochemical upflow anaerobic sludge blanket (BE-UASB) was constructed and compared with the traditional UASB to investigate the role of bioelectrocatalysis in modulating methanogenesis and sulfidogensis involved within anaerobic treatment of high-sulfate methanolic wastewater (COD/SO42- ratio ≤ 2). Methane production rate for BE-UASB was 1.4 times higher than that of the single UASB, while SO42- removal stabilized at 16.7%. Bioelectrocatalysis selectively enriched key functional anaerobes and stimulated the secretion of extracellular polymeric substances, especially humic acids favoring electron transfer, thereby accelerating the electroactive biofilms development of electrodes. Methanomethylovorans was the dominant genus (35%) to directly convert methanol to CH4. Methanobacterium as CO2 electroreduction methane-producing archaea appeared only on electrodes. Acetobacterium exhibited anode-dependence, which provided acetate for sulfate-reducing bacteria (norank Syntrophobacteraceae and Desulfomicrobium) through synergistic coexistence. This study confirmed that BE-UASB regulated the microbial ecology to achieve efficient removal and energy recovery of high-sulfate methanolic wastewater.


Assuntos
Metano , Metanol , Esgotos , Sulfatos , Águas Residuárias , Águas Residuárias/microbiologia , Metanol/metabolismo , Metano/metabolismo , Sulfatos/metabolismo , Esgotos/microbiologia , Anaerobiose , Reatores Biológicos/microbiologia , Eletrodos
17.
Water Res ; 256: 121557, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38581982

RESUMO

Electrochemical anaerobic membrane bioreactor (EC-AnMBR) by integrating a composite anodic membrane (CAM), represents an effective method for promoting methanogenic performance and mitigating membrane fouling. However, the development and formation of electroactive biofilm on CAM, and the spatio-temporal distribution of key functional microorganisms, especially the degradation mechanism of organic pollutants in metabolic pathways were not well documented. In this work, two AnMBR systems (EC-AnMBR and traditional AnMBR) were constructed and operated to identify the role of CAM in metabolic pathway on biogas upgrading and mitigation of membrane fouling. The methane yield of EC-AnMBR at HRT of 20 days was 217.1 ± 25.6 mL-CH4/g COD, about 32.1 % higher compared to the traditional AnMBR. The 16S rRNA analysis revealed that the EC-AnMBR significantly promoted the growth of hydrolysis bacteria (Lactobacillus and SJA-15) and methanogenic archaea (Methanosaeta and Methanobacterium). Metagenomic analysis revealed that the EC-AnMBR promotes the upregulation of functional genes involved in carbohydrate metabolism (gap and kor) and methane metabolism (mtr, mcr, and hdr), improving the degradation of soluble microbial products (SMPs)/extracellular polymeric substances (EPS) on the CAM and enhancing the methanogens activity on the cathode. Moreover, CAM biofilm exhibits heterogeneity in the degradation of organic pollutants along its vertical depth. The bacteria with high hydrolyzing ability accumulated in the upper part, driving the feedstock degradation for higher starch, sucrose and galactose metabolism. A three-dimensional mesh-like cake structure with larger pores was formed as a biofilter in the middle and lower part of CAM, where the electroactive Geobacter sulfurreducens had high capabilities to directly store and transfer electrons for the degradation of organic pollutants. This outcome will further contribute to the comprehension of the metabolic mechanisms of CAM module on membrane fouling control and organic solid waste treatment and disposal.


Assuntos
Biocombustíveis , Reatores Biológicos , Membranas Artificiais , Reatores Biológicos/microbiologia , Anaerobiose , RNA Ribossômico 16S/genética , Metano/metabolismo , Biofilmes , Bactérias/metabolismo , Incrustação Biológica
18.
Nat Commun ; 15(1): 4441, 2024 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-38789409

RESUMO

Ideal hydrogel fibers with high toughness and environmental tolerance are indispensable for their long-term application in flexible electronics as actuating and sensing elements. However, current hydrogel fibers exhibit poor mechanical properties and environmental instability due to their intrinsically weak molecular (chain) interactions. Inspired by the multilevel adjustment of spider silk network structure by ions, bionic hydrogel fibers with elaborated ionic crosslinking and crystalline domains are constructed. Bionic hydrogel fibers show a toughness of 162.25 ± 21.99 megajoules per cubic meter, comparable to that of spider silks. The demonstrated bionic structural engineering strategy can be generalized to other polymers and inorganic salts for fabricating hydrogel fibers with broadly tunable mechanical properties. In addition, the introduction of inorganic salt/glycerol/water ternary solvent during constructing bionic structures endows hydrogel fibers with anti-freezing, water retention, and self-regeneration properties. This work provides ideas to fabricate hydrogel fibers with high mechanical properties and stability for flexible electronics.

19.
Quant Imaging Med Surg ; 14(2): 1860-1872, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38415146

RESUMO

Background: For patients with suspected simultaneous coronary and cerebrovascular atherosclerosis, conventional single-site computed tomography angiography (CTA) for both sites can result in nonnegligible radiation and contrast agent dose. The purpose of this study was to validate the feasibility of one-stop coronary and carotid-cerebrovascular CTA (C&CC-CTA) with a "double-low" (low radiation and contrast) dose protocol reconstructed with deep learning image reconstruction with high setting (DLIR-H) algorithm. Methods: From February 2018 to January 2019, 60 patients referred to C&CC-CTA simultaneously in West China Hospital were recruited in this prospective cohort study. By random assignment, patients were divided into two groups: double-low dose group (n=30) used 80 kVp and 24 mgI/kg/s contrast dose with images reconstructed using DLIR-H; and routine-dose group (n=30) used 100 kVp and 32 mgI/kg/s contrast dose with images reconstructed using 50% adaptive statistical iterative reconstruction-V (ASIR-V50%). Radiation and contrast doses, subjective image quality score, CT attenuation values, noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were measured and compared between the groups. Results: The DLIR-H group used 30% less contrast dose (35.80±4.85 vs. 51.13±6.91 mL) and 48% less overall radiation dose (1.00±0.09 vs. 1.91±0.42 mSv) than the ASIR-V50% group (both P<0.001). There was no statistically significant difference on subjective quality score between the two groups (C-CTA: 4.38±0.67 vs. 4.17±0.81, P=0.337 and CC-CTA: 4.18±0.87 vs. 4.08±0.79, P=0.604). For coronary CTA, lower background noise (18.93±1.43 vs. 22.86±3.75 HU) was reached in DLIR-H group, and SNR and CNR at all assessed branches were significantly increased compared to ASIR-V50% group (all P<0.05), except SNR of left anterior descending (P>0.05). For carotid-cerebrovascular CTA, DLIR-H group was comparable in background noise (19.25±1.42 vs. 20.23±2.40 HU), SNR and CNR at all assessed branches with ASIR-V50% group (all P>0.05). Conclusions: The "double-low" dose one-stop C&CC-CTA with DLIR-H obtained higher image quality compared with the routine-dose protocol with ASIR-V50% while achieving 48% and 30% reduction in radiation and contrast dose, respectively.

20.
Sci Total Environ ; 905: 167006, 2023 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-37722426

RESUMO

Thick electrochemically active biofilms (EABs) will lead to insufficient extracellular electron transfer (EET) rate because of the limitation of both substrate diffusion and electron exchange. Herein, carbon nanotubes (CNTs)-doped EABs are developed through self-assembly. The highly conductive biofilms (internal resistance of ∼211 Ω) are efficiently enriched at CNTs dosage of 1 g L-1, with the stable power output of 0.568 W m-2 over three months. The embedded CNTs can act as electron tunnel to accelerate the EET rate in thick biofilm. Self-charging/discharging experiments and Nernst-Monod model stimulation demonstrate a higher net charge storage capacity (0.15 C m-2) and more negative half-saturation potential (-0.401 V) for the hybrid biofilms than that of the control (0.09 C m-2, and -0.378 V). Enzyme activity tests and the observation of confocal laser scanning microscopy by live/dead staining show a nearly negligible cytotoxicity of CNTs, and non-targeted metabonomics analysis reveals fourteen differential metabolites that do not play key roles in microbial central metabolic pathways according to KEGG compound database. The abundance of typical exoelectrogens Geobacter sp. is 2-fold of the control, resulting in a better bioelectrocatalytic activity. These finding provide a possible approach to prolong electron exchange and power output by developing a hybrid EABs doped with conductive material.


Assuntos
Fontes de Energia Bioelétrica , Nanotubos de Carbono , Nanotubos de Carbono/toxicidade , Elétrons , Eletrodos , Biofilmes , Transporte de Elétrons
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA