Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Eur Radiol ; 34(1): 39-49, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37552259

RESUMO

OBJECTIVES: Quantitative CT imaging is an important emphysema biomarker, especially in smoking cohorts, but does not always correlate to radiologists' visual CT assessments. The objectives were to develop and validate a neural network-based slice-wise whole-lung emphysema score (SWES) for chest CT, to validate SWES on unseen CT data, and to compare SWES with a conventional quantitative CT method. MATERIALS AND METHODS: Separate cohorts were used for algorithm development and validation. For validation, thin-slice CT stacks from 474 participants in the prospective cross-sectional Swedish CArdioPulmonary bioImage Study (SCAPIS) were included, 395 randomly selected and 79 from an emphysema cohort. Spirometry (FEV1/FVC) and radiologists' visual emphysema scores (sum-visual) obtained at inclusion in SCAPIS were used as reference tests. SWES was compared with a commercially available quantitative emphysema scoring method (LAV950) using Pearson's correlation coefficients and receiver operating characteristics (ROC) analysis. RESULTS: SWES correlated more strongly with the visual scores than LAV950 (r = 0.78 vs. r = 0.41, p < 0.001). The area under the ROC curve for the prediction of airway obstruction was larger for SWES than for LAV950 (0.76 vs. 0.61, p = 0.007). SWES correlated more strongly with FEV1/FVC than either LAV950 or sum-visual in the full cohort (r = - 0.69 vs. r = - 0.49/r = - 0.64, p < 0.001/p = 0.007), in the emphysema cohort (r = - 0.77 vs. r = - 0.69/r = - 0.65, p = 0.03/p = 0.002), and in the random sample (r = - 0.39 vs. r = - 0.26/r = - 0.25, p = 0.001/p = 0.007). CONCLUSION: The slice-wise whole-lung emphysema score (SWES) correlates better than LAV950 with radiologists' visual emphysema scores and correlates better with airway obstruction than do LAV950 and radiologists' visual scores. CLINICAL RELEVANCE STATEMENT: The slice-wise whole-lung emphysema score provides quantitative emphysema information for CT imaging that avoids the disadvantages of threshold-based scores and is correlated more strongly with reference tests than LAV950 and reader visual scores. KEY POINTS: • A slice-wise whole-lung emphysema score (SWES) was developed to quantify emphysema in chest CT images. • SWES identified visual emphysema and spirometric airflow limitation significantly better than threshold-based score (LAV950). • SWES improved emphysema quantification in CT images, which is especially useful in large-scale research.


Assuntos
Obstrução das Vias Respiratórias , Enfisema , Doença Pulmonar Obstrutiva Crônica , Enfisema Pulmonar , Humanos , Estudos Prospectivos , Estudos Transversais , Enfisema Pulmonar/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Enfisema/diagnóstico por imagem , Obstrução das Vias Respiratórias/diagnóstico por imagem
2.
Acta Radiol ; 65(3): 307-317, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38115809

RESUMO

BACKGROUND: Magnetic resonance imaging (MRI) is useful in the diagnosis of clinically significant prostate cancer (csPCa). MRI-derived radiomics may support the diagnosis of csPCa. PURPOSE: To investigate whether adding radiomics from biparametric MRI to predictive models based on clinical and MRI parameters improves the prediction of csPCa in a multisite-multivendor setting. MATERIAL AND METHODS: Clinical information (PSA, PSA density, prostate volume, and age), MRI reviews (PI-RADS 2.1), and radiomics (histogram and texture features) were retrieved from prospectively included patients examined at different radiology departments and with different MRI systems, followed by MRI-ultrasound fusion guided biopsies of lesions PI-RADS 3-5. Predictive logistic regression models of csPCa (Gleason score ≥7) for the peripheral (PZ) and transition zone (TZ), including clinical data and PI-RADS only, and combined with radiomics, were built and compared using receiver operating characteristic (ROC) curves. RESULTS: In total, 456 lesions in 350 patients were analyzed. In PZ and TZ, PI-RADS 4-5 and PSA density, and age in PZ, were independent predictors of csPCa in models without radiomics. In models including radiomics, PI-RADS 4-5, PSA density, age, and ADC energy were independent predictors in PZ, and PI-RADS 5, PSA density and ADC mean in TZ. Comparison of areas under the ROC curve (AUC) for the models without radiomics (PZ: AUC = 0.82, TZ: AUC = 0.80) versus with radiomics (PZ: AUC = 0.82, TZ: AUC = 0.82) showed no significant differences (PZ: P = 0.366; TZ: P = 0.171). CONCLUSION: PSA density and PI-RADS are potent predictors of csPCa. Radiomics do not add significant information to our multisite-multivendor dataset.


Assuntos
Imageamento por Ressonância Magnética , Neoplasias da Próstata , Masculino , Humanos , Imageamento por Ressonância Magnética/métodos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Antígeno Prostático Específico , Radiômica , Curva ROC , Estudos Retrospectivos
3.
Acta Radiol ; 64(5): 1859-1864, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36749001

RESUMO

The Swedish Society of Uroradiology has revised their computed tomography (CT) guidelines regarding iodine contrast media-induced acute kidney injury (CI-AKI). They are more cautious compared to the European Society of Urogenital Radiology and the American College of Radiology since the actual risk of CI-AKI remains uncertain in patients with moderate to severe kidney damage due to a lack of prospective controlled studies and mainly based on retrospective propensity score-matched studies with low-grade evidence. Another source of uncertainty is the imprecision of glomerular filtration rate (GFR) estimating equations. However, randomized hydration studies indictae an upper limit risk of CI-AKI of about 5% for outpatients with a GFR in the range of 30-44 or 45-59 mL/min/1.73m2 combined with multiple risk factors. Apart from GFR limits, the guideline also includes limits for systemic contrast medium exposure expressed in gram-iodine/GFR ratio.


Assuntos
Injúria Renal Aguda , Iodo , Humanos , Iodo/efeitos adversos , Suécia , Estudos Retrospectivos , Injúria Renal Aguda/induzido quimicamente , Radiografia , Meios de Contraste/efeitos adversos , Fatores de Risco , Taxa de Filtração Glomerular
4.
Eur Radiol ; 31(8): 5980-5989, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33635394

RESUMO

OBJECTIVES: To prospectively validate three quantitative single-energy CT (SE-CT) methods for classifying uric acid (UA) and non-uric acid (non-UA) stones. METHODS: Between September 2018 and September 2019, 116 study participants were prospectively included in the study if they had at least one 3-20-mm urinary stone on an initial urinary tract SE-CT scan. An additional dual-energy CT (DE-CT) scan was performed, limited to the stone of interest. Additionally, to include a sufficient number of UA stones, eight participants with confirmed UA stone on DE-CT were retrospectively included. The SE-CT stone features used in the prediction models were (1) maximum attenuation (maxHU) and (2) the peak point Laplacian (ppLapl) calculated at the position in the stone with maxHU. Two prediction models were previously published methods (ppLapl-maxHU and maxHU) and the third was derived from the previous results based on the k-nearest neighbors (kNN) algorithm (kNN-ppLapl-maxHU). The three methods were evaluated on this new independent stone dataset. The reference standard was the CT vendor's DE-CT application for kidney stones. RESULTS: Altogether 124 participants (59 ± 14 years, 91 men) with 106 non-UA and 37 UA stones were evaluated. For classification of UA and non-UA stones, the sensitivity, specificity, and accuracy were 100% (37/37), 97% (103/106), and 98% (140/143), respectively, for kNN-ppLapl-maxHU; 95% (35/37), 98% (104/106), and 97% (139/143) for ppLapl-maxHU; and 92% (34/37), 94% (100/106), and 94% (134/143) for maxHU. CONCLUSION: A quantitative SE-CT method (kNN-ppLapl-maxHU) can classify UA stones with accuracy comparable to DE-CT. KEY POINTS: • Single-energy CT is the first-line diagnostic tool for suspected renal colic. • A single-energy CT method based on the internal urinary stone attenuation distribution can classify urinary stones into uric acid and non-uric acid stones with high accuracy. • This immensely increases the availability of in vivo stone analysis.


Assuntos
Ácido Úrico , Cálculos Urinários , Humanos , Masculino , Estudos Prospectivos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Cálculos Urinários/diagnóstico por imagem
5.
J Card Surg ; 36(10): 3702-3708, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34312919

RESUMO

BACKGROUND: Randomized trials show high long-term patency for no-touch saphenous vein grafts in coronary artery bypass grafting. The patency rate in off-pump coronary bypass surgery for these grafts has not been investigated. Our center participated in the CORONARY randomized trial, NCT00463294. This is a study aimed to assess the patency of no-touch saphenous veins in on- versus off-pump coronary bypass surgery at five-year follow-up. METHODS: Fifty-six patients were included. Forty of 49 patients, alive at 5 years, participated in this follow-up. There were 21 and 19 patients in the on- and off-pump groups respectively. No-touch saphenous veins were used to bypass all targets and in some cases the left anterior descending artery. Graft patency according to distal anastomosis was evaluated with computed tomography angiography. RESULTS: The five-year patency rate was 123/139 (88.5%). The patency for the no-touch vein grafts was 57/64 (89.1%) in the on-pump versus 37/45 (82.2%) in the off-pump group. All left internal thoracic arteries except for one, 29/30 (96.6%), were patent. All vein grafts used to bypass the left anterior descending and the diagonal arteries were patent 32/32. The lowest patency rate for the saphenous veins was to the right coronary territory, particularly in off-pump surgery (80.0% vs. 62.5% for the on- respective off-pump groups). CONCLUSIONS: Comparable 5-year patency for the no-touch saphenous veins and the left internal thoracic arteries to the left anterior descending territory in both on- and off-pump coronary artery bypass grafting. Graft patency in off-pump CABG is lower to the right coronary artery.


Assuntos
Artéria Torácica Interna , Angiografia Coronária , Ponte de Artéria Coronária , Humanos , Veia Safena/diagnóstico por imagem , Resultado do Tratamento , Grau de Desobstrução Vascular
6.
J Digit Imaging ; 33(5): 1185-1193, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32779016

RESUMO

Emphysema is visible on computed tomography (CT) as low-density lesions representing the destruction of the pulmonary alveoli. To train a machine learning model on the emphysema extent in CT images, labeled image data is needed. The provision of these labels requires trained readers, who are a limited resource. The purpose of the study was to test the reading time, inter-observer reliability and validity of the multi-reader-multi-split method for acquiring CT image labels from radiologists. The approximately 500 slices of each stack of lung CT images were split into 1-cm chunks, with 17 thin axial slices per chunk. The chunks were randomly distributed to 26 readers, radiologists and radiology residents. Each chunk was given a quick score concerning emphysema type and severity in the left and right lung separately. A cohort of 102 subjects, with varying degrees of visible emphysema in the lung CT images, was selected from the SCAPIS pilot, performed in 2012 in Gothenburg, Sweden. In total, the readers created 9050 labels for 2881 chunks. Image labels were compared with regional annotations already provided at the SCAPIS pilot inclusion. The median reading time per chunk was 15 s. The inter-observer Krippendorff's alpha was 0.40 and 0.53 for emphysema type and score, respectively, and higher in the apical part than in the basal part of the lungs. The multi-split emphysema scores were generally consistent with regional annotations. In conclusion, the multi-reader-multi-split method provided reasonably valid image labels, with an estimation of the inter-observer reliability.


Assuntos
Enfisema Pulmonar , Feminino , Humanos , Pulmão , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Enfisema Pulmonar/diagnóstico por imagem , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X
7.
Eur Radiol ; 28(6): 2474-2483, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29368161

RESUMO

OBJECTIVES: To compare the ability of different size estimates to predict spontaneous passage of ureteral stones using a 3D-segmentation and to investigate the impact of manual measurement variability on the prediction of stone passage. METHODS: We retrospectively included 391 consecutive patients with ureteral stones on non-contrast-enhanced CT (NECT). Three-dimensional segmentation size estimates were compared to the mean of three radiologists' measurements. Receiver-operating characteristic (ROC) analysis was performed for the prediction of spontaneous passage for each estimate. The difference in predicted passage probability between the manual estimates in upper and lower stones was compared. RESULTS: The area under the ROC curve (AUC) for the measurements ranged from 0.88 to 0.90. Between the automated 3D algorithm and the manual measurements the 95% limits of agreement were 0.2 ± 1.4 mm for the width. The manual bone window measurements resulted in a > 20 percentage point (ppt) difference between the readers in the predicted passage probability in 44% of the upper and 6% of the lower ureteral stones. CONCLUSIONS: All automated 3D algorithm size estimates independently predicted the spontaneous stone passage with similar high accuracy as the mean of three readers' manual linear measurements. Manual size estimation of upper stones showed large inter-reader variations for spontaneous passage prediction. KEY POINTS: • An automated 3D technique predicts spontaneous stone passage with high accuracy. • Linear, areal and volumetric measurements performed similarly in predicting stone passage. • Reader variability has a large impact on the predicted prognosis for stone passage.


Assuntos
Imageamento Tridimensional/métodos , Cálculos Ureterais/diagnóstico por imagem , Cálculos Ureterais/patologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Probabilidade , Prognóstico , Curva ROC , Remissão Espontânea , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Adulto Jovem
8.
Eur Radiol ; 27(11): 4775-4785, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28593428

RESUMO

OBJECTIVES: To determine how to most accurately predict the chance of spontaneous passage of a ureteral stone using information in the diagnostic non-enhanced computed tomography (NECT) and to create predictive models with smaller stone size intervals than previously possible. METHODS: Retrospectively 392 consecutive patients with ureteric stone on NECT were included. Three radiologists independently measured the stone size. Stone location, side, hydronephrosis, CRP, medical expulsion therapy (MET) and all follow-up radiology until stone expulsion or 26 weeks were recorded. Logistic regressions were performed with spontaneous stone passage in 4 weeks and 20 weeks as the dependent variable. RESULTS: The spontaneous passage rate in 20 weeks was 312 out of 392 stones, 98% in 0-2 mm, 98% in 3 mm, 81% in 4 mm, 65% in 5 mm, 33% in 6 mm and 9% in ≥6.5 mm wide stones. The stone size and location predicted spontaneous ureteric stone passage. The side and the grade of hydronephrosis only predicted stone passage in specific subgroups. CONCLUSION: Spontaneous passage of a ureteral stone can be predicted with high accuracy with the information available in the NECT. We present a prediction method based on stone size and location. KEY POINTS: • Non-enhanced computed tomography can predict the outcome of ureteral stones. • Stone size and location are the most important predictors of spontaneous passage. • Prediction models based on stone width or length and stone location are introduced. • The observed passage rates for stone size in mm-intervals are reported. • Clinicians can make better decisions about treatment.


Assuntos
Tomografia Computadorizada por Raios X , Cálculos Ureterais/diagnóstico por imagem , Cálculos Ureterais/patologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Hidronefrose/diagnóstico por imagem , Hidronefrose/patologia , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Probabilidade , Prognóstico , Remissão Espontânea , Estudos Retrospectivos , Adulto Jovem
9.
J Heart Valve Dis ; 26(5): 502-508, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-29762918

RESUMO

BACKGROUND: Flow measurements using cardiac magnetic resonance imaging (CMRI) enable quantification of the stroke volume, regurgitant volume (RV) and regurgitant fraction (RF) in patients with aortic regurgitation (AR). These variables are used to assess the severity of the valve disease and for the timing of surgery. The aim of the study was to investigate the impact of an increased heart rate on measurement of the RV and RF in patients with AR. METHODS: Among 13 patients with known moderate or severe AR, regurgitant flow measurements, using phase-contrast cine magnetic resonance imaging, were obtained in the ascending aorta. Flow measurements were obtained at rest and at increased heart rates after intravenous administration of atropine. RESULTS: The mean heart rate was 61 beats per min at rest and 91 beats per min after atropine administration. The RV and RF were 52 ml and 35% at rest, respectively, and 34 ml (p <0.001) and 30% (p = 0.065) at increased heart rate, respectively. CONCLUSIONS: An increased heart rate leads to a decreased RV. The RF is more stable and may therefore be preferable for severity grading in AR.


Assuntos
Insuficiência da Valva Aórtica , Atropina/farmacologia , Velocidade do Fluxo Sanguíneo/fisiologia , Frequência Cardíaca/efeitos dos fármacos , Idoso , Antiarrítmicos/farmacologia , Insuficiência da Valva Aórtica/diagnóstico , Insuficiência da Valva Aórtica/fisiopatologia , Ecocardiografia/métodos , Feminino , Frequência Cardíaca/fisiologia , Humanos , Imagem Cinética por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Volume Sistólico , Tempo para o Tratamento
10.
Cardiovasc Ultrasound ; 15(1): 4, 2017 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-28270161

RESUMO

BACKGROUND: There is today no established approach to estimate right ventricular ejection fraction (RVEF) using 2D transthoracic echocardiography (TTE). The aim of this study was to evaluate a new method for RVEF calculations using 2D TTE and compare the results with cardiac magnetic resonance (CMR) imaging and tricuspid annular plane systolic excursion (TAPSE). METHODS: A total of 37 subjects, 25 retrospectively included patients and twelve healthy volunteers, were included to give a wide range of RVEF. The right ventricle (RV) was modeled as a part of an ellipsoid enabling calculation of the RV volume by combining three distance measurements. RVEF calculated according to the model, RVEFTTE, were compared with reference CMR-derived RVEF, RVEFCMR. Further, TAPSE was measured in the TTE images and the correlations were calculated between RVEFTTE, TAPSE and RVEFCMR. RESULTS: The mean values were RVEFCMR = 43 ± 12% (range 20-66%) and RVEFTTE = 50 ± 9% (range 34-65%). There was a high correlation (r = 0.80, p < 0.001) between RVEFTTE and RVEFCMR. Bland-Altman analysis showed a mean difference between RVEFCMR and RVEFTTE of 6 percentage points (ppt) with limits of agreement from -11 to 23 ppt. The mean value for TAPSE was 19 ± 5 mm and the correlation between TAPSE and RVEFCMR was moderate (r = 0.54, p < 0.001). The correlation between RVEFTTE and RVEFCMR was significantly higher (p < 0.05) than the correlation between TAPSE and RVEFCMR. CONCLUSIONS: The ellipsoid model shows promise for RVEF calculations using 2D TTE for a wide range of RVEF, providing RVEF estimates that were significantly better correlated to RVEF obtained from CMR compared to TAPSE.


Assuntos
Ventrículos do Coração/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Imagem Cinética por Ressonância Magnética/métodos , Modelos Teóricos , Volume Sistólico/fisiologia , Disfunção Ventricular Direita/fisiopatologia , Função Ventricular Direita/fisiologia , Adulto , Feminino , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Disfunção Ventricular Direita/diagnóstico
11.
Acta Radiol ; 58(6): 702-709, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28157395

RESUMO

Background Iterative reconstruction (IR) is a recent reconstruction algorithm for computed tomography (CT) that can be used instead of the standard algorithm, filtered back projection (FBP), to reduce radiation dose and/or improve image quality. Purpose To evaluate and compare the image quality of low-dose CT of the lumbar spine reconstructed with IR to conventional FBP, without further reduction of radiation dose. Material and Methods Low-dose CT on 55 patients was performed on a Siemens scanner using 120 kV tube voltage, 30 reference mAs, and automatic dose modulation. From raw CT data, lumbar spine CT images were reconstructed with a medium filter (B41f) using FBP and four levels of IR (levels 2-5). Five reviewers scored all images on seven image quality criteria according to the European guidelines on quality criteria for CT, using a five-grade scale. A side-by-side comparison was also performed. Results There was significant improvement in image quality for IR (levels 2-4) compared to FBP. According to visual grading regression, odds ratios of all criteria with 95% confidence intervals for IR2, IR3, IR4, and IR5 were: 1.59 (1.39-1.83), 1.74 (1.51-1.99), 1.68 (1.46-1.93), and 1.08 (0.94-1.23), respectively. In the side-by-side comparison of all reconstructions, images with IR (levels 2-4) received the highest scores. The mean overall CTDIvol was 1.70 mGy (SD 0.46; range, 1.01-3.83 mGy). Image noise decreased in a linear fashion with increased strength of IR. Conclusion Iterative reconstruction at levels 2, 3, and 4 improves image quality of low-dose CT of the lumbar spine compared to FPB.


Assuntos
Processamento de Imagem Assistida por Computador , Vértebras Lombares/diagnóstico por imagem , Doses de Radiação , Tomografia Computadorizada por Raios X , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X/métodos , Adulto Jovem
12.
Echocardiography ; 33(6): 844-53, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26841195

RESUMO

BACKGROUND: The position of the right ventricle (RV), often partly behind the sternum, implies difficulties to image the RV free wall using transthoracic echocardiography (TTE) and consequently limits the possibilities of stroke volume calculations. The aim of this study was to evaluate whether the volume of the right ventricle (RV) can be determined by combining TTE distance measurements that do not need the RV free wall to be fully visualized. METHODS: The RV volume was approximated by an ellipsoid composed of three distances. Distance measurements, modeled RV stroke volumes (RVSV), and RV ejection fraction (RVEF) were compared to reference values obtained from cardiac magnetic resonance (CMR) imaging for 12 healthy volunteers. RESULTS: Inter-modality comparisons showed that distance measurements were significantly underestimated in TTE compared to CMR. The modeled RV volumes using TTE distance measurements were underestimated compared to reference CMR volumes. There was, however, for TTE an agreement between modeled RVSV and left ventricular stroke volumes determined by biplane Simpson's rule. Similar agreement was shown between modeled RVSV based on CMR distance measurements and the CMR reference. Regarding RVEF, further studies including patients with a wider range of RVEF are needed to evaluate the method. CONCLUSION: In conclusion, the ellipsoid model of the RV provides good estimates of RVSVs, but volumes based on distance measurements from different modalities cannot be used interchangeably.


Assuntos
Pontos de Referência Anatômicos/anatomia & histologia , Pontos de Referência Anatômicos/diagnóstico por imagem , Ecocardiografia Tridimensional/métodos , Ventrículos do Coração/anatomia & histologia , Ventrículos do Coração/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Adolescente , Adulto , Idoso , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão , Sensibilidade e Especificidade , Volume Sistólico , Adulto Jovem
13.
Acta Radiol ; 57(5): 602-11, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26221055

RESUMO

BACKGROUND: Lumbar spine radiography is often performed instead of CT for radiation dose concerns. PURPOSE: To compare image quality and diagnostic information from low dose lumbar spine CT at an effective dose of about 1 mSv with lumbar spine radiography. MATERIAL AND METHODS: Fifty-one patients were examined by both methods. Five reviewers scored all examinations on eight image quality criteria using a five-graded scale and also assessed three common pathologic changes. RESULTS: Low dose CT scored better than radiography on the following: sharp reproduction of disc profile and vertebral end-plates (odds ratio [OR], 1.8; 95% confidence interval [CI], 1.3-2.5), intervertebral foramina and pedicles (OR, 4.3; 95% CI, 3.1-5.9), intervertebral joints (OR, 139; 95% CI, 59-326), spinous and transverse processes (OR, 7.0; 95% CI, 4.3-11.2), sacro-iliac joints (OR, 4.2; 95% CI, 3.2-5.7), reproduction of the adjacent soft tissues (OR, 2.9; 95% CI, 2.1-4.0), and absence of any obscuring superimposed gastrointestinal gas and contents (OR, 188; 95% CI, 66-539). Radiography scored better on sharp reproduction of cortical and trabecular bone (OR, 0.3; 95% CI, 0.2-0.4). The reviewers visualized disk degeneration, spondylosis/diffuse idiopathic skeletal hyperostosis (DISH) and intervertebral joint osteoarthritis more clearly and were more certain with low dose CT. Mean time to review low dose CT was 204 s (95% CI, 194-214 s.), radiography 152 s (95% CI, 146-158 s.). The effective dose for low dose CT was 1.0-1.1 mSv, for radiography 0.7 mSv. CONCLUSION: Low dose lumbar spine CT at about 1 mSv has superior image quality to lumbar spine radiography with more anatomical and diagnostic information.


Assuntos
Vértebras Lombares/diagnóstico por imagem , Doses de Radiação , Doenças da Coluna Vertebral/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
14.
Scand Cardiovasc J ; 49(1): 27-38, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25614080

RESUMO

OBJECTIVES: Takotsubo cardiomyopathy (TTC) is a condition of transient left ventricular (LV) dysfunction. The effects on LV mass (LVM) and geometry have not been studied enough in TTC. Retrospectively, we analyzed our TTC cohort both by transthoracic echocardiography (TTE) and magnetic resonance imaging (MRI), for comparative purposes. DESIGN: Thirteen women undergoing TTE and MRI, at onset and three months later, were included. LVM was estimated by MRI, and two TTE methods. Segmental wall thickness (SWT) was measured, while radial strain was assessed by TTE. Data analysis included Wilcoxon's test (between phases), Mann-Whitney U test and McNemar's test (between and within groups). Bland-Altman analyses were used for intertechnique coherence, while interactions regarding TTE were tested using Spearman's coefficient. RESULTS: LVM decreased during recovery (p < 0.05), by MRI and one of the TTE methods; truncated ellipsoid formula (TEF), which also showed relatively better coherence compared with MRI. SWT decreased in two of three sites, by both modalities, but with ambiguous coherence there between. The TEF data interacted partially with a demonstrated increase in radial strain. CONCLUSIONS: TTC associates with acute increase in LVM, which appears to be an apical effect, tending to follow the changes in concentric wall motion. MRI and TTE show adequate coherence; primarily for the TEF method regarding LVM.


Assuntos
Ecocardiografia Doppler , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/patologia , Imagem Cinética por Ressonância Magnética , Cardiomiopatia de Takotsubo/diagnóstico , Idoso , Feminino , Ventrículos do Coração/fisiopatologia , Humanos , Contração Miocárdica , Variações Dependentes do Observador , Valor Preditivo dos Testes , Prognóstico , Reprodutibilidade dos Testes , Estudos Retrospectivos , Cardiomiopatia de Takotsubo/diagnóstico por imagem , Cardiomiopatia de Takotsubo/patologia , Cardiomiopatia de Takotsubo/fisiopatologia , Fatores de Tempo , Função Ventricular Esquerda
15.
Acta Radiol ; 56(4): 487-92, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24646626

RESUMO

BACKGROUND: The standard imaging procedure for a patient presenting with renal colic is unenhanced computed tomography (CT). The CT measured size has a close correlation to the estimated prognosis for spontaneous passage of a ureteral calculus. Size estimations of urinary calculi in CT images are still based on two-dimensional (2D) reformats. PURPOSE: To develop and validate a calculus oriented three-dimensional (3D) method for measuring the length and width of urinary calculi and to compare the calculus oriented measurements of the length and width with corresponding 2D measurements obtained in axial and coronal reformats. MATERIAL AND METHODS: Fifty unenhanced CT examinations demonstrating urinary calculi were included. A 3D symmetric segmentation algorithm was validated against reader size estimations. The calculus oriented size from the segmentation was then compared to the estimated size in axial and coronal 2D reformats. RESULTS: The validation showed 0.1 ± 0.7 mm agreement against reference measure. There was a 0.4 mm median bias for 3D estimated calculus length compared to 2D (P < 0.001), but no significant bias for 3D width compared to 2D. CONCLUSION: The length of a calculus in axial and coronal reformats becomes underestimated compared to 3D if its orientation is not aligned to the image planes. Future studies aiming to correlate calculus size with patient outcome should use a calculus oriented size estimation.


Assuntos
Imageamento Tridimensional/métodos , Tomografia Computadorizada por Raios X/métodos , Cálculos Urinários/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador/métodos , Reprodutibilidade dos Testes , Estudos Retrospectivos
16.
BMJ Case Rep ; 17(2)2024 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-38331446

RESUMO

A woman in her 80s experienced a life-threatening complication of pacemaker implant consisting of subacute right ventricular lead perforation causing iatrogenic injury to an intercostal artery, resulting in a large haemothorax. A CT scan confirmed active bleeding from the fourth intercostal artery. The patient underwent cardiothoracic surgery via a median sternotomy approach, during which the source of the bleeding was sealed, a new epicardial lead was positioned, and the original lead was extracted. This case emphasises the potentially severe consequences of pacemaker lead perforation and secondary injury to adjacent structures. It underscores the importance of early recognition and timely intervention, preferably in a tertiary specialist unit equipped for cardiothoracic surgery and confirms the value of pacemaker interrogation and CT scans for diagnosis.


Assuntos
Traumatismos Cardíacos , Marca-Passo Artificial , Feminino , Humanos , Artérias , Traumatismos Cardíacos/diagnóstico por imagem , Traumatismos Cardíacos/etiologia , Traumatismos Cardíacos/cirurgia , Hemorragia/diagnóstico por imagem , Hemorragia/etiologia , Hemorragia/terapia , Hemotórax/diagnóstico por imagem , Hemotórax/etiologia , Hemotórax/cirurgia , Doença Iatrogênica , Marca-Passo Artificial/efeitos adversos , Idoso de 80 Anos ou mais
17.
J Occup Environ Med ; 2024 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-38788162

RESUMO

OBJECTIVE: To study infection, hospitalisation, and admission to ICU for COVID-19 in different occupations and pandemic waves in a Swedish county. METHODS: Individual registry data of infection and hospitalisation were merged with occupational data in, this cross-sectional study. Infected, hospital- and ICU-admission were analysed by occupational groups. RESULTS: 22,095 cases of COVID-19 from 21 February 2021 to 31 August 2022 were identified. Healthcare workers and others working in close physical proximity showed a higher rate of confirmed COVID-19 infections in all waves and higher risk for hospital admission early in the pandemic. Exposure to diseases and physical proximity played a decisive role. CONCLUSION: Workers in close-contact occupations experienced a higher rate of confirmed infections throughout the pandemic and higher hospitalisation rates in the first pandemic wave, suggesting a need for more effective initial safety measures in a future pandemic.

18.
Urolithiasis ; 51(1): 66, 2023 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-37027057

RESUMO

We aimed to externally validate five previously published predictive models (Ng score, Triple D score, S3HoCKwave score, Kim nomogram, Niwa nomogram) for shock wave lithotripsy (SWL) single-session outcomes in patients with a solitary stone in the upper ureter. The validation cohort included patients treated with SWL from September 2011 to December 2019 at our institution. Patient-related variables were retrospectively collected from the hospital records. Stone-related data including all measurements were retrieved from computed tomography prior to SWL. We estimated discrimination using area under the curve (AUC), calibration, and clinical net benefit based on decision curve analysis (DCA). A total of 384 patients with proximal ureter stones treated with SWL were included in the analysis. Median age was 55.5 years, and 282 (73%) of the sample were men. Median stone length was 8.0 mm. All models significantly predicted the SWL outcomes after one session. S3HoCKwave score, Niwa, and Kim nomograms had the highest accuracy in predicting outcomes, with AUC 0.716, 0.714 and 0.701, respectively. These three models outperformed both the Ng (AUC: 0.670) and Triple D (AUC: 0.667) scoring systems, approaching statistical significance (P = 0.05). Of all the models, the Niwa nomogram showed the strongest calibration and highest net benefit in DCA. To conclude, the models showed small differences in predictive power. The Niwa nomogram, however, demonstrated acceptable discrimination, the most accurate calibration, and the highest net benefit whilst having relatively simple design. Therefore, it could be useful for counselling patients with a solitary stone in the upper ureter.


Assuntos
Cálculos Renais , Litotripsia , Cálculos Ureterais , Masculino , Humanos , Pessoa de Meia-Idade , Feminino , Cálculos Ureterais/terapia , Estudos Retrospectivos , Resultado do Tratamento , Litotripsia/métodos , Cálculos Renais/terapia
19.
Eur Radiol ; 22(4): 731-7, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22160167

RESUMO

OBJECTIVES: The size estimation in CT images of an obstructing ureteral calculus is important for the clinical management of a patient presenting with renal colic. The objective of the present study was to develop a reader independent urinary calculus segmentation algorithm using well-known digital image processing steps and to validate the method against size estimations by several readers. METHODS: Fifty clinical CT examinations demonstrating urinary calculi were included. Each calculus was measured independently by 11 readers. The mean value of their size estimations was used as validation data for each calculus. The segmentation algorithm consisted of interpolated zoom, binary thresholding and morphological operations. Ten examinations were used for algorithm optimisation and 40 for validation. Based on the optimisation results three segmentation method candidates were identified. RESULTS: Between the primary segmentation algorithm using cubic spline interpolation and the mean estimation by 11 readers, the bias was 0.0 mm, the standard deviation of the difference 0.26 mm and the Bland-Altman limits of agreement 0.0 ± 0.5 mm. CONCLUSIONS: The validation showed good agreement between the suggested algorithm and the mean estimation by a large number of readers. The limit of agreement was narrower than the inter-reader limit of agreement previously reported for the same data. KEY POINTS: The size of kidney stones is usually estimated manually by the radiologist. An algorithm for computer-aided size estimation is introduced. The variability between readers can be reduced. A reduced variability can give better information for treatment decisions.


Assuntos
Algoritmos , Reconhecimento Automatizado de Padrão/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Cálculos Urinários/diagnóstico por imagem , Urografia/métodos , Humanos , Variações Dependentes do Observador , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
20.
Acta Radiol ; 53(6): 689-94, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22798385

RESUMO

BACKGROUND: Dual-energy computed tomography (DECT) has been shown to be useful for subtracting bone or calcium in CT angiography and gives an opportunity to produce a virtual non-contrast-enhanced (VNC) image from a series where contrast agents have been given intravenously. High noise levels and low resolution have previously limited the diagnostic value of the VNC images created with the first generation of DECT. With the recent introduction of a second generation of DECT, there is a possibility of obtaining VNC images with better image quality at hopefully lower radiation dose compared to the previous generation. PURPOSE: To compare the image quality of the single-energy series to a VNC series obtained with a two generations of DECT scanners. CT of the urinary tract was used as a model. MATERIAL AND METHODS: Thirty patients referred for evaluation of hematuria were examined with an older system (Somatom Definition) and another 30 patients with a new generation (Somatom Definition Flash). One single-energy series was obtained before and one dual-energy series after administration of intravenous contrast media. We created a VNC series from the contrast-enhanced images. Images were assessed concerning image quality with a visual grading scale evaluation of the VNC series with the single-energy series as gold standard. RESULTS: The image quality of the VNC images was rated inferior to the single-energy variant for both scanners, OR 11.5-67.3 for the Definition and OR 2.1-2.8 for the Definition Flash. Visual noise and overall quality were regarded as better with Flash than Definition. CONCLUSION: Image quality of VNC images obtained with the new generation of DECT is still slightly inferior compared to native images. However, the difference is smaller with the new compared to the older system.


Assuntos
Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Doenças Urológicas/diagnóstico por imagem , Interface Usuário-Computador , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Hematúria/complicações , Hematúria/diagnóstico por imagem , Humanos , Pessoa de Meia-Idade , Variações Dependentes do Observador , Razão de Chances , Estudos Prospectivos , Intensificação de Imagem Radiográfica/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Urografia/métodos , Doenças Urológicas/complicações , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA