Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Analyst ; 148(2): 316-327, 2023 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-36484412

RESUMO

Most nucleic acid biosensors employ nucleic acid-processing enzymes to bind, degrade, splice, synthesize, and modify nucleic acids. Utilizing their unique substrate preference, binding mode, and catalytic activity is of great importance in designing nucleic acid biosensors. Combination with DNA-processing enzymes enables them to transform into a new generation of molecular diagnostics tools with enhanced selectivity and sensitivity and reduced reaction time. Here, we report an isothermal amplification strategy by coemploying a structure-specific endonuclease (flap endonuclease 1, FEN1) and a strand-displacing DNA polymerase (Bst DNA polymerase) to detect long RNA targets. This approach couples the FEN1-driven invasive cleavage reaction with toehold-mediated rolling circle amplification (iFEN-tRCA), enabling the highly selective and rapid detection of long RNA targets and offering a detection limit below 10 pM within 1 h. We used two targets, such as human epidermal growth factor receptor 2 (HER2, encoded by ERBB2) and dopamine- and cyclic AMP-regulated phosphoprotein (DARPP, encoded by PPP1R1B), associated with prognosis or response to anticancer therapy. We demonstrated the feasibility and quantitative capability of the iFEN-tRCA assay by assessing the expression of two RNA transcripts (ERBB2 and PPP1R1B) with total RNA extracts purified from human breast cancer cells. Therefore, we envision that the developed assay will provide a suitable prognostic and diagnostic tool for identifying appropriate patients for HER2-targeted therapy and predicting the clinical outcome and occurrence of metastasis relapse in breast cancer.


Assuntos
Neoplasias da Mama , Humanos , Feminino , Neoplasias da Mama/diagnóstico , Neoplasias da Mama/genética , Transcriptoma , Técnicas de Amplificação de Ácido Nucleico , DNA/genética , DNA/metabolismo , DNA Polimerase Dirigida por DNA/química , RNA
2.
Anal Chem ; 94(8): 3535-3542, 2022 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-35061345

RESUMO

With the growth of drug-facilitated crimes, prevention has become increasingly important. Although various drug detection technologies exist, most focus on postconsumption detection. However, the prevention of drug-facilitated crimes requires technology for the quick and easy detection of amphetamine-type stimulants (ATSs) before ingestion. Herein, drug screening kits (DSKs) were developed for the simple detection of ATSs in drinks. The DSKs consisted of polydiacetylene nanofiber-based paper sensors fabricated by electrospinning with 10,12-pentacosadiynoic acid (PCDA) and PCDA-dopamine as sensing materials that can bind ATSs via hydrogen bonding and π-π interactions. Dropping a drink on the DSK provided an immediate visual indication of the presence of ATSs. When ATSs were present in the drink, the color of the DSK clearly changed from blue to red, with the increase in red intensity being more than twofold greater than that observed when water alone was tested. Notably, the result could be confirmed by the naked eye without any analytical instrumentation. A color change indicating the presence of ATSs was successfully observed in various alcoholic and nonalcoholic drinks. These results indicate the potential of DSKs for preventing drug-facilitated crimes caused by unwanted drug intake.


Assuntos
Estimulantes do Sistema Nervoso Central , Nanofibras , Anfetamina , Colorimetria/métodos
3.
Chem Eng J ; 442: 136143, 2022 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-35382003

RESUMO

Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection has led to a pandemic of acute respiratory disease, namely coronavirus disease (COVID-19). This disease threatens human health and public safety. Early diagnosis, isolation, and prevention are important to suppress the outbreak of COVID 19 given the lack of specific antiviral drugs to treat this disease and the emergence of various variants of the virus that cause breakthrough infections even after vaccine administration. Simple and prompt testing is paramount to preventing further spread of the virus. However, current testing methods, namely RT-PCR, is time-consuming. Binding of the SARS-CoV-2 spike (S) glycoprotein to human angiotensin-converting enzyme 2 (hACE2) receptor plays a pivotal role in host cell entry. In the present study, we developed a hACE2 mimic peptide beacon (COVID19-PEB) for simple detection of SARS-CoV-2 using a fluorescence resonance energy transfer system. COVID19-PEB exhibits minimal fluorescence in its ''closed'' hairpin structure; however, in the presence of SARS-CoV-2, the specific recognition of the S protein receptor-binding domain by COVID19-PEB causes the beacon to assume an ''open'' structure that emits strong fluorescence. COVID19-PEB can detect SARS-CoV-2 within 3 h or even 50 min and exhibits strong fluorescence even at low viral concentrations, with a detection limit of 4 × 103 plaque-forming unit/test. Furthermore, in SARS-CoV-2-infected patient samples confirmed using polymerase chain reaction, COVID19-PEB accurately detected the virus. COVID19-PEB could be developed as a rapid and accurate diagnostic tool for COVID-19.

4.
Talanta ; 275: 126073, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38688085

RESUMO

Methicillin-resistant Staphylococcus aureus (MRSA) has a high incidence in infectious hospitals and communities, highlighting the need for early on-site detection due to its resistance to methicillin antibiotics. The present study introduces a highly sensitive detection system for mecA, a crucial methicillin marker, utilizing an RCA-based isothermal exponential amplification reaction. The G-quadruplex-based isothermal exponential amplification reaction (GQ-EXPAR) method designs probes to establish G-quadruplex secondary structures incorporating thioflavin T for fluorescence. The system, unlike conventional genetic detection methods, works with portable isothermal PCR devices (isoQuark), facilitating on-site detection. A detection limit of 0.1 fmol was demonstrated using synthetic DNA, and effective detection was proven using thermal lysis. The study also validated the detection of targets swabbed from surfaces within bacterial 3D nanostructures using the GQ-EXPAR method. After applying complementary sequences to the padlock probe for the target, the GQ-EXPAR method can be used on various targets. The developed method could facilitate rapid and accurate diagnostics within MRSA strains.


Assuntos
Quadruplex G , Staphylococcus aureus Resistente à Meticilina , Técnicas de Amplificação de Ácido Nucleico , Staphylococcus aureus Resistente à Meticilina/isolamento & purificação , Staphylococcus aureus Resistente à Meticilina/genética , Técnicas de Amplificação de Ácido Nucleico/métodos , Limite de Detecção , Proteínas de Ligação às Penicilinas , Proteínas de Bactérias/genética , DNA Bacteriano/genética , DNA Bacteriano/análise , Benzotiazóis/química , Humanos
5.
Biosens Bioelectron ; 259: 116375, 2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-38749283

RESUMO

Since the outbreak of the novel severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) at the end of 2019, the spread of the virus has posed a significant threat to public health and the global economy. This work proposed a one-step, dual-structure-switching aptamer-mediated signal amplification cascade for rapid and sensitive detection of the SARS-CoV-2 nucleocapsid protein. This system consisted of two DNA aptamers with structure-switching functionality and fuel DNA, where a cascade of strand hybridization and displacement triggered fluorescence generation and signal amplification. This aptamer-based amplification cascade required neither an amplification stage using enzymes nor pre-processing steps such as washing, viral isolation, and gene extraction. The assay could distinguish SARS-CoV-2 from other respiratory viruses and detect up to 1.0 PFU/assay of SARS-CoV-2 within 30 min at room temperature. In 35 nasopharyngeal clinical samples, the assay accurately assessed 25 positive and 10 negative clinical swab samples, which were confirmed using quantitative polymerase chain reaction. The strategy reported herein can help detect newly emerging pathogens and biomarkers of various diseases in liquid samples. In addition, the developed detection system consisting of only DNA and fluorophores can be widely integrated into liquid biopsy platforms for disease diagnosis.


Assuntos
Aptâmeros de Nucleotídeos , Técnicas Biossensoriais , COVID-19 , Técnicas de Amplificação de Ácido Nucleico , SARS-CoV-2 , SARS-CoV-2/isolamento & purificação , SARS-CoV-2/genética , Humanos , Técnicas Biossensoriais/métodos , Aptâmeros de Nucleotídeos/química , COVID-19/virologia , COVID-19/diagnóstico , Técnicas de Amplificação de Ácido Nucleico/métodos , Proteínas do Nucleocapsídeo de Coronavírus/genética , Fosfoproteínas/química , Limite de Detecção , Teste de Ácido Nucleico para COVID-19/métodos , Teste de Ácido Nucleico para COVID-19/instrumentação
6.
Biosens Bioelectron ; 239: 115592, 2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37603987

RESUMO

Exosomes are useful for cancer diagnosis and monitoring. However, clinical samples contain impurities that complicate direct analyses of cancer-derived exosomes. Therefore, a microfluidic chip-based magnetically labeled exosome isolation system (MEIS-chip) was developed as a lab-on-a-chip platform for human epidermal growth factor receptor 2 (HER2)-positive cancer diagnosis and monitoring. Various magnetic nanoclusters (MNCs) were synthesized with different degrees of magnetization, and antibodies were introduced to capture HER2-overexpressing and common exosomes using immunoaffinity. MNC-bonded exosomes were separated into different exits according to their magnetization degrees. The MEIS-chip efficiently separated HER2-overexpressing exosomes from common exosomes that did not contain disease-related information. The simultaneous separation of HER2-and non-HER2-overexpressing exosomes provided a means of analyzing high-purity HER2-overexpressing exosomes while minimizing the contribution of non-target exosomes, reducing misdiagnosis risk. Notably, common exosomes served as a negative control for monitoring real-time changes in HER2 expression. These findings support the application of MEIS-chip for cancer diagnosis and treatment monitoring via effective exosome isolation.


Assuntos
Técnicas Biossensoriais , Exossomos , Neoplasias , Humanos , Microfluídica , Neoplasias/diagnóstico , Anticorpos
7.
ACS Appl Mater Interfaces ; 15(6): 7759-7766, 2023 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-36748606

RESUMO

Infectious agents such as viruses pose significant threats to human health, being transmitted via direct contact as well as airborne transmission without direct contact, thus requiring rapid detection to prevent the spread of infectious diseases. In this study, we developed a conductive thread-based immunosensor (CT-IS), a biosensor to easily detect the presence of airborne viruses. CT-IS utilizes an antibody that specifically recognizes the HA protein of the pandemic influenza A (pH1N1) virus, which is incorporated into the conductive thread. The antigen-antibody interaction results in increased strain on the conductive thread in the presence of the pH1N1 virus, resulting in increased electrical resistance of the CT-IS. We evaluated the performance of this sensor using the HA protein and the pH1N1 virus, in addition to samples from patients infected with the pH1N1 virus. We observed a significant change in resistance in the pH1N1-infected patient samples (positive: n = 11, negative: n = 9), whereas negligible change was observed in the control samples (patients not infected with the pH1N1 virus; negative). Hence, the CT-IS is a lightweight fiber-type sensor that can be used as a wearable biosensor by combining it with textiles, to detect the pH1N1 virus in a person's vicinity.


Assuntos
Técnicas Biossensoriais , Vírus da Influenza A Subtipo H1N1 , Influenza Humana , Humanos , Influenza Humana/diagnóstico , Imunoensaio , Anticorpos
8.
J Hazard Mater ; 460: 132398, 2023 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-37639787

RESUMO

Over the past few years, infections caused by airborne pathogens have spread worldwide, infecting several people and becoming an increasingly severe threat to public health. Therefore, there is an urgent need for developing airborne pathogen monitoring technology for use in confined environments to enable epidemic prevention. In this study, we designed a colorimetry-based bacterial detection platform that uses a clustered regularly interspaced short palindromic repeat-associated protein 12a system to amplify signals and a urease enzyme to induce color changes. Furthermore, we have developed a smartphone application that can distinguish colors under different illumination conditions based on the HSV model and detect three types of disease-causing bacteria. Even synthetic oligomers of a few picomoles of concentration and genomic DNA of airborne bacteria smaller than several nanograms can be detected with the naked eye and using color analysis systems. Furthermore, in the air capture model system, the bacterial sample generated approximately a 2-fold signal difference compared with that in the control group. This colorimetric detection method can be widely applied for public safety because it is easy to use and does not require complex equipment.


Assuntos
Colorimetria , Smartphone , Humanos , Bactérias/genética , Modelos Biológicos , Saúde Pública
9.
Food Chem ; 403: 134317, 2023 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-36182855

RESUMO

Ingesting large quantities of biogenic amines (BAs), which are released from spoiled foods, can have adverse side effects on the human body. Herein, we developed a colorimetric sensor using polydiacetylene (PDA)-based hydrogel beads that change color upon binding with BAs, thereby conveniently checking whether food is spoiled due to improper storage and distribution. The colorimetric sensor is fabricated by mixing PDA liposomes with an alginate solution. PDA undergoes a color change from blue to red when exposed to various external stimuli. In addition, alginate bestows the hydrogel with a three-dimensional porous structure, affording a large surface area. The PDA-based hydrogel beads can visually confirm the presence of BAs in solution or vapor form. Cadaverine and propylamine were rapidly detected with distinct color changes in the solution and vapor phases, respectively. The spoilage of pork meat at room temperature could be detected after two days as a 40.84% red chromatic shift.


Assuntos
Colorimetria , Hidrogéis , Humanos , Colorimetria/métodos , Aminas Biogênicas , Carne/análise , Alginatos
10.
Talanta ; 246: 123502, 2022 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-35523021

RESUMO

MicroRNAs (miRNAs) are important diagnostic and prognostic biomarkers for various tumors. Currently, many diagnostic systems have been developed to detect miRNAs, but simple techniques for detecting miRNAs are still required. Recently, we reported that the expression of miRNA-135b is upregulated in gastric epithelial cells during gastric inflammation and carcinogenesis. Our aim was to develop an in vitro diagnostic platform to analyze the expression of gastric cancer-related biomarkers in the blood. The diagnostic platform comprised an isothermal amplification-based lateral flow biosensor (IA-LFB) that enables easy diagnosis of gastric cancer through visual observation. In this platform, trace amounts of biomarkers are isothermally amplified through rolling circle amplification (RCA), and the amplified product is grafted to the LFB. The performance of the IA-LFB was confirmed using RNAs extracted from in vitro and in vivo models. The platform could detect target miRNAs within 3 h with excellent sensitivity and selectivity. In particular, the IA-LFB could detect the overexpression of gastric cancer-related markers (miRNA-135b and miRNA-21) in RNAs extracted from the blood of patients with various stages (stages 1-4) of gastric cancer compared to that in healthy volunteers. Therefore, IA-LFB is a simple and sensitive in vitro diagnostic system for detecting gastric cancer-related biomarkers and can contribute to the early diagnosis and prognosis monitoring of gastric cancer. Furthermore, this technology can be applied to systems that can detect multiple biomarkers related to various diseases (such as infectious and genetic diseases).


Assuntos
Técnicas Biossensoriais , MicroRNAs , Neoplasias Gástricas , Técnicas Biossensoriais/métodos , Humanos , MicroRNAs/genética , Técnicas de Amplificação de Ácido Nucleico/métodos , Neoplasias Gástricas/diagnóstico , Neoplasias Gástricas/genética
11.
Biosens Bioelectron ; 209: 114279, 2022 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-35447599

RESUMO

Alzheimer's disease (AD), one of the leading senile disorders in the world, causes severe memory loss and cognitive impairment. To date, there is no clear cure for AD. However, early diagnosis and monitoring can help mitigate the effects of this disease. In this study, we reported a platform for diagnosing early-stage AD using microRNAs (miRNAs) in the blood as biomarkers. First, we selected an appropriate target miRNA (miR-574-5p) using AD model mice (4-month-old 5XFAD mice) and developed a hydrogel-based sensor that enabled high-sensitivity detection of the target miRNA. This hydrogel contained catalytic hairpin assembly (CHA) reaction-based probes, leading to fluorescence signal amplification without enzymes and temperature changes, at room temperature. This sensor exhibited high sensitivity and selectivity, as evidenced by its picomolar-level detection limit (limit of detection: 1.29 pM). Additionally, this sensor was evaluated using the plasma of AD patients and non-AD control to validate its clinical applicability. Finally, to use this sensor as a point-of-care-testing (POCT) diagnostic system, a portable fluorometer was developed and verified for feasibility of application.


Assuntos
Doença de Alzheimer , Técnicas Biossensoriais , MicroRNAs , Animais , Diagnóstico Precoce , Humanos , Hidrogéis , Camundongos , MicroRNAs/genética
12.
Biosens Bioelectron ; 209: 114256, 2022 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-35430408

RESUMO

In this study, we uncover a ligation-free DNA extension method in two adjacent fragmented probes, which are hybridized to target RNA, for developing a ligation-free nucleic acid amplification reaction. In this reaction, DNA elongation occurs from a forward probe to a phosphorothioated-hairpin probe in the presence of target RNA regardless of ligation. The second DNA elongation then occurs simultaneously at the nick site of the phosphorothioated probe and the self-priming region. Therefore, the binding site of the clustered regularly interspaced short palindromic repeats (CRISPR)/CRISPR-associated protein (Cas) 12a is repeatedly amplified, inducing a fluorescence signal in the presence of CRISPR-Cas12a. This ligation-free isothermal gene amplification method enables the detection of target RNA with 49.2 fM sensitivity. Moreover, two types of mRNA detection are feasible, thus, demonstrating the potential of this method for cancer companion diagnostics. Notably, the proposed method also demonstrates efficacy when applied for the detection of mRNA extracted from human cells and tumor-bearing mouse tissue and urine samples. Hence, this newly developed ligation-free isothermal nucleic acid amplification system is expected to be widely used in a variety of gene detection platforms.


Assuntos
Técnicas Biossensoriais , Sistemas CRISPR-Cas , Animais , Técnicas Biossensoriais/métodos , Sistemas CRISPR-Cas/genética , DNA/genética , Camundongos , Técnicas de Amplificação de Ácido Nucleico/métodos , RNA , RNA Mensageiro
13.
Biosens Bioelectron ; 197: 113753, 2022 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-34741958

RESUMO

Metastasis attributed to approximately 90% of cancer-related deaths; hence, the detection of metastatic tumor-derived components in the blood assists in determining cancer recurrence and patient survival. Microfluidic-based sensors facilitate analysis of small fluid volumes and represent an accurate, rapid, and user-friendly method of field diagnoses. In this study, we have developed a microfluidic chip-based exosomal mRNA sensor (exoNA-sensing chip) for the one-step detection of exosomal ERBB2 in the blood by integrating a microfluidic chip and 3D-nanostructured hydrogels. The exoNA-sensing chip is a vacuum-driven power-free microfluidic chip that can accurately control the flow of trace fluids (<100 µL). The sensing part of the exoNA-sensing chip includes 3D-nanostructured hydrogels capable of detecting ERBB2 and a reference gene by amplifying a fluorescent signal via an enzyme-free catalytic hairpin assembly reaction at room temperature. This hydrogel offers a detection limit of 58.3 fM with good selectivity for target sequences. The performance of the exoNA-sensing chip was evaluated by testing in vitro and in vivo samples and was proven to be effective for cancer diagnosis and liquid biopsies.


Assuntos
Técnicas Biossensoriais , Neoplasias da Mama , Nanoestruturas , Neoplasias da Mama/diagnóstico , Neoplasias da Mama/genética , Feminino , Humanos , Dispositivos Lab-On-A-Chip , RNA Mensageiro/genética
14.
ACS Sens ; 5(10): 3099-3108, 2020 10 23.
Artigo em Inglês | MEDLINE | ID: mdl-32786378

RESUMO

Biological metamaterials with a specific size and spacing are necessary for developing highly sensitive and selective sensing systems to detect hazardous bacteria in complex solutions. Herein, the construction of peptidoglycan-binding protein (PGBP)-based metamaterials to selectively capture Gram-positive cells with high efficacy is reported. Nanoimprint lithography was used to generate a nanohole pattern as a template, the inside of which was modified with nickel(II)-nitrilotriacetic acid (Ni-NTA). Then, PGBP metamaterials were fabricated by immobilizing PGBP via chelation between Ni-NTA and six histidines on PGBP. Compared to the flat and spread PGBP-covered bare substrates, the PGBP-based metamaterials enabled selective capturing of Gram-positive bacteria with high efficacy, owing to enhanced interactions between the metamaterials and bacterial surface not shown in bulk materials. Thereafter, the specific strain and quantitative information of the captured bacteria was obtained by surface-enhanced Raman scattering mapping analysis in the 1 to 1 × 106 cfu/mL range within 30 min. It should be noted that no additional signal amplification process was required for lowly abundant bacteria, even at the single-bacterium level. The PGBP-based metamaterials could be regenerated multiple times with preserved sensing efficiency. Finally, this assay can detect specific Gram-positive bacteria, such as Staphylococcus aureus, in human plasma.


Assuntos
Peptidoglicano , Análise Espectral Raman , Bactérias , Proteínas de Transporte , Bactérias Gram-Positivas , Humanos
15.
Biosens Bioelectron ; 167: 112474, 2020 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-32798804

RESUMO

Exosomal messenger RNA (mRNA) has emerged as a valuable biomarker for liquid biopsy-based disease diagnosis and prognosis due to its stability in body fluids and its biological regulatory function. Here, we report a rapid one-step isothermal gene amplification reaction based on three-way junction (3WJ) formation and the successful detection of urinary exosomal mRNA from tumor-bearing mice. The 3WJ structure can be formed by the association of 3WJ probes (3WJ-template and 3WJ-primer) in the presence of target RNA. After 3WJ structure formation, the 3WJ primer is repeatedly extended and cleaved by a combination of DNA polymerase and nicking endonuclease, producing multiple signal primers. Subsequently, the signal primers promote a specially designed network reaction pathway to produce G-quadruplex probes under isothermal conditions. Finally, G-quadruplex structure produces highly enhanced fluorescence signal upon binding to thioflavin T. This method provides a detection limit of 1.23 pM (24.6 amol) with high selectivity for the target RNA. More importantly, this method can be useful for the sensing of various kinds of mRNA, including breast cancer cellular mRNA, breast cancer exosomal mRNA, and even urinary exosomal mRNA from breast cancer mice. We anticipate that the developed RNA detection assay can be used for various biomedical applications, such as disease diagnosis, prognosis, and treatment monitoring.


Assuntos
Técnicas Biossensoriais , Quadruplex G , Animais , Amplificação de Genes , Limite de Detecção , Camundongos , Técnicas de Amplificação de Ácido Nucleico , RNA Mensageiro
16.
ACS Omega ; 4(11): 14560-14568, 2019 Sep 10.
Artigo em Inglês | MEDLINE | ID: mdl-31528810

RESUMO

Several microRNAs (miRNAs) have been reported to be closely related to influenza A virus infection, replication, and immune response. Therefore, the development of the infectious-disease detection system using miRNAs as biomarkers is actively underway. Herein, we identified two miRNAs (miR-181c-5p and miR-1254) as biomarkers for detection of pandemic influenza A H1N1 virus infection and proposed the catalytic hairpin assembly-based in vitro diagnostic (CIVD) system for a highly sensitive diagnosis; this system is composed of two sets of cascade hairpin probes enabling to detect miR-181c-5p and miR-1254. We demonstrated that CIVD kits could not only detect subnanomolar levels of target miRNAs but also distinguish even single-base mismatches. Moreover, this CIVD kit has shown excellent detection performance in real intracellular RNA samples and confirmed results similar to those of conventional methods (microarray and quantitative real-time polymerase chain reaction).

17.
Nanomaterials (Basel) ; 9(6)2019 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-31146479

RESUMO

Wearable devices are becoming widespread in a wide range of applications, from healthcare to biomedical monitoring systems, which enable continuous measurement of critical biomarkers for medical diagnostics, physiological health monitoring and evaluation. Especially as the elderly population grows globally, various chronic and acute diseases become increasingly important, and the medical industry is changing dramatically due to the need for point-of-care (POC) diagnosis and real-time monitoring of long-term health conditions. Wearable devices have evolved gradually in the form of accessories, integrated clothing, body attachments and body inserts. Over the past few decades, the tremendous development of electronics, biocompatible materials and nanomaterials has resulted in the development of implantable devices that enable the diagnosis and prognosis through small sensors and biomedical devices, and greatly improve the quality and efficacy of medical services. This article summarizes the wearable devices that have been developed to date, and provides a review of their clinical applications. We will also discuss the technical barriers and challenges in the development of wearable devices, and discuss future prospects on wearable biosensors for prevention, personalized medicine and real-time health monitoring.

18.
Nanomaterials (Basel) ; 9(3)2019 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-30862030

RESUMO

We designed a high-sensitivity magnetic resonance imaging contrast agent that could be used to diagnose diseases. First, magnetic nanocrystals were synthesized by a thermal decomposition method on an organic solvent to obtain a high magnetism and methoxy poly(ethylene glycol)-poly(lactic acid) as an amphiphilic polymer using the ring-opening polymerization method to stably disperse the magnetic nanocrystals in an aqueous phase. Subsequently, the magnetic nanoclusters simultaneously self-assembled with methoxy poly(ethylene glycol)-poly(lactic acid) using the nano-emulsion method to form magnetic nanoclusters. Because their shape was similar to a raspberry, they were named PEGylated magnetic nano-assemblies. The PEGylated magnetic nano-assemblies were dispersed stably in the aqueous phase with a uniform size of approximately 65⁻70 nm for an extended period (0 days: 68.8 ± 5.1 nm, 33 days: 69.2 ± 2.0 nm, and 44 days: 63.2 ± 5.6). They exhibited both enough of a magnetic resonance (MR) contrast effect and biocompatibility. In an in vivo study, the PEGylated magnetic nano-assemblies provided a high contrast effect for magnetic resonance images for a long time after one treatment, thereby improving the diagnostic visibility of the disease site.

19.
Chem Commun (Camb) ; 55(24): 3457-3460, 2019 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-30735212

RESUMO

We have proposed a novel strategy for miRNA detection through enzyme-free signal amplification by self-circulation of the hybridization between the miRNAs and molecular beacon (MB) circuits. Unlike general MB-based miRNA detection based on the one-to-one (1 : 1) hybridization between MBs and miRNA, our system consists of four species of MBs (MBs A, B, C and D) (MB circuits) and is activated by a hybridization chain reaction. MBs stably coexist as hairpin structures that hardly show fluorescence signals in the absence of target miRNA. After miRNA detection, this MB circuit is able to generate fluorescence signals and amplify the fluorescence signal, contributing to improvement in detection sensitivity under iso-thermal conditions without an enzyme. Furthermore, in vitro and in vivo studies have proven that MB circuits can detect low levels of miRNA with high sensitivity, compared to when only one MB alone is used. Therefore, the MB circuits can provide a useful platform for target miRNA detection.


Assuntos
MicroRNAs/análise , Hibridização de Ácido Nucleico/métodos , Espectrometria de Fluorescência/métodos , Animais , Neoplasias da Mama/diagnóstico por imagem , Linhagem Celular Tumoral , Feminino , Fluorescência , Humanos , Limite de Detecção , Camundongos , Imagem Óptica/métodos
20.
Sci Rep ; 9(1): 129, 2019 01 15.
Artigo em Inglês | MEDLINE | ID: mdl-30644425

RESUMO

Peptidoglycan-binding protein-modified magnetic nanobeads (PGBP-MNBs) were prepared for efficient magnetic capturing of Staphylococcus aureus (S. aureus), which is associated with sepsis, using the binding affinity of PGBP for the peptidoglycan (PG) layer on S. aureus. These PGBP-MNBs can simply capture S. aureus in plasma within 1 hr or even 15 min. Importantly, they also can capture various types of Gram-positive bacteria, such as Bacillus cereus and methicillin-resistant and methicillin-susceptible S. aureus (MRSA and MSSA). We believe that PGBP-based systems will be used to develop diagnostic systems for Gram-positive bacteria-related diseases.


Assuntos
Separação Imunomagnética/métodos , Sepse/microbiologia , Staphylococcus aureus/isolamento & purificação , Proteínas de Bactérias/metabolismo , Proteínas de Transporte/metabolismo , Bactérias Gram-Positivas/isolamento & purificação , Humanos , Peptidoglicano/metabolismo , Ligação Proteica , Sepse/sangue , Staphylococcus aureus/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA