Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 38
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Osteoporos Int ; 35(7): 1185-1193, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38563961

RESUMO

The epidemiological data on osteogenesis imperfecta (OI) in Asia is limited. This study, representing the first comprehensive epidemiological investigation on OI in Taiwan, reveals high medical resource utilization and underscores the importance of early diagnosis to enhance care quality. INTRODUCTION: This study examines osteogenesis imperfecta, a hereditary connective tissue disorder causing pediatric fractures and limb deformities, using a nationwide database from Taiwan to analyze clinical features and medical burden. METHODS: The study identified validated OI patients from the Catastrophic Illness Registry in the National Health Insurance Research Database from 2008 to 2019. Demographic data and medical resource utilization were analyzed. A multivariate Cox model assessed the influence of sex, validation age, and comorbidities. RESULTS: 319 OI patients (M/F = 153/166) were identified, with 58% validated before age 20. Prevalence and incidence were 0.8-1.3/100,000 and 0.02-0.09/100,000, respectively, with higher rates in the pediatric demographic. In the study period, 69.6% of the patients had admission history, primarily to pediatric and orthopedic wards. The median admission number was 3, with a median length of stay of 12 days and a median inpatient cost of approximately 3,163 USD during the period. Lower limb fractures were the main reason for hospitalization. 57% of OI patients received bisphosphonate treatment. The leading causes of mortality were OI-related deaths, neurovascular disease, and cardiovascular disease. The median age of validation in the non-survival group was significantly higher compared to the survival group (33 vs. 14 years), and patients validated during childhood required more inpatient fracture surgeries than those validated during adulthood. CONCLUSION: This study provides comprehensive real-world evidence on the clinical characteristics and high medical resource utilization of OI patients in a low prevalence region like Taiwan. Early diagnosis is crucial for improving care quality and enhancing health outcomes.


Assuntos
Bases de Dados Factuais , Osteogênese Imperfeita , Humanos , Osteogênese Imperfeita/epidemiologia , Osteogênese Imperfeita/complicações , Masculino , Feminino , Criança , Adolescente , Pré-Escolar , Taiwan/epidemiologia , Adulto Jovem , Lactente , Adulto , Prevalência , Incidência , Efeitos Psicossociais da Doença , Pessoa de Meia-Idade , Hospitalização/estatística & dados numéricos , Comorbidade , Distribuição por Idade , Sistema de Registros , Recém-Nascido , Distribuição por Sexo , Tempo de Internação/estatística & dados numéricos
2.
Medicina (Kaunas) ; 58(10)2022 Oct 06.
Artigo em Inglês | MEDLINE | ID: mdl-36295564

RESUMO

Observations of a symptomatic discoid lateral meniscus in young children are infrequent. The objective of this report was to demonstrate the use of arthroscopic saucerization and repair for treating a bucket-handle tear of a lateral discoid meniscus in two young children. Two young children (a 28-month-old girl and a 5-year-old boy) presented with a bucket-handle tear of the complete type lateral discoid meniscus. Both patients received arthroscopic saucerization and repair. A full knee extension under a long leg cast was applied for one month after surgery. The two patients were able to achieve a full range of motion of their operated knees without limping or presenting an antalgic gait at the third month after surgery. Both patients and their parents felt satisfied with the treatment at the 2- and 3-year follow-ups, respectively. Our results demonstrated that arthroscopic saucerization and repair seems to be an effective treatment for bucket-handle tears of the lateral discoid meniscus in young children-even those younger than 3 years old. We reported the youngest case (a 28-month-old girl) in comparison with the findings from a literature review.


Assuntos
Doenças das Cartilagens , Lesões do Menisco Tibial , Criança , Masculino , Feminino , Humanos , Pré-Escolar , Meniscos Tibiais/cirurgia , Artroscopia , Lesões do Menisco Tibial/cirurgia , Articulação do Joelho/cirurgia , Estudos Retrospectivos
3.
J Formos Med Assoc ; 114(12): 1211-5, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25312255

RESUMO

BACKGROUND/PURPOSE: Premature adjacent-level degeneration has been attributed to vertebral fusion, but spondylolisthesis has not been reported as a pathological factor responsible for the degeneration of adjacent disc and facet joint. We hypothesized that the degeneration of disc and facet joints in the adjacent levels is correlated with spondylolisthesis. METHODS: Magnetic resonance images of 35 symptomatic young adults (16-29 years old) with low-grade L5-S1 spondylolytic spondylolisthesis (Meyerding Grade 1 or 2) and 50 symptomatic young referents (20-29 years old) with L5-S1 disc herniation without spondylolisthesis were recruited to compare the differences between disc and facet-joint degenerations at the olisthetic and adjacent levels using the Mantel extension test. RESULTS: There were statistically significant degenerative changes of the discs and facet joints at the olisthetic and adjacent levels of patients with spondylolytic spondylolisthesis compared with the reference group. There is a trend that the disc and facet joints degenerate the most at the olisthetic level and become less affected at adjacent levels away from the lesion of pars defect. CONCLUSION: Low-grade spondylolytic spondylolisthesis was associated with significant degenerations of the disc and facet joints at olisthetic and adjacent levels in young adults.


Assuntos
Disco Intervertebral/patologia , Espondilolistese/diagnóstico por imagem , Articulação Zigapofisária/patologia , Adolescente , Adulto , Feminino , Humanos , Disco Intervertebral/diagnóstico por imagem , Dor Lombar/etiologia , Imageamento por Ressonância Magnética , Masculino , Amplitude de Movimento Articular , Estudos Retrospectivos , Ciática/etiologia , Espondilolistese/fisiopatologia , Taiwan , Adulto Jovem , Articulação Zigapofisária/diagnóstico por imagem
4.
J Shoulder Elbow Surg ; 24(4): 547-54, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25457784

RESUMO

BACKGROUND: An abduction brace and abduction exercises are commonly employed after humeral greater tuberosity fracture repair. However, the effects of glenohumeral abduction on the biomechanical strength have seldom been elucidated. METHOD: We studied 24 pairs of female fresh frozen porcine shoulders randomly divided into 3 groups. After creation of a greater tuberosity fracture on each shoulder, 3 fixation techniques were used for the 3 groups: double-row suture anchor fixation (DR), suture bridge technique (SB), and 2-screw fixation (TS). This biomechanical study was conducted to compare the forces that create 3- and 5-mm displacements and the ultimate failure load at the simulated shoulder abduction angles of 0° and 45° among the 3 groups. RESULTS: In the DR group, the mean forces to create 3- and 5-mm displacements and the failure load at 0° were higher than those at 45° (P = .036, P = .012, P = .027). By contrast, in the SB group, the mean forces to create 3- and 5-mm displacements at 45° were greater than those at 0° (P = .012, P = .012). There were no significant differences in the forces to create 3- and 5-mm displacements and construct failure between 0° and 45° in the TS group (P = .575, .327, .478). CONCLUSION: The DR group had greatest initial fixation strength at a low abduction angle, whereas the SB group had the highest initial fixation strength at a high abduction angle. The TS group appeared unaffected by the abduction angle.


Assuntos
Fixação Interna de Fraturas/métodos , Fraturas do Úmero/cirurgia , Articulação do Ombro/cirurgia , Animais , Fenômenos Biomecânicos , Parafusos Ósseos , Feminino , Fixação Interna de Fraturas/instrumentação , Úmero/cirurgia , Âncoras de Sutura , Técnicas de Sutura , Suínos , Suporte de Carga
5.
Knee Surg Sports Traumatol Arthrosc ; 22(2): 431-4, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23179454

RESUMO

Clavicle fractures are common traumatic injuries of the shoulder girdle, with surgery being the recommended treatment for some displaced midshaft fractures. Open surgery is widely used; however, the primary concerns of this procedure include cosmetic problems and incisional complications, such as wound dehiscence, infection, numbness, and sensitivity. A new arthroscopically assisted technique was developed, in which the Knowles pin was used for percutaneous fixation to treat the displaced midclavicular fracture. This technique is an attractive alternative treatment option for midclavicular fractures.


Assuntos
Artroscopia/métodos , Pinos Ortopédicos , Clavícula/lesões , Fixação Interna de Fraturas/métodos , Fraturas Ósseas/cirurgia , Clavícula/cirurgia , Fixação Interna de Fraturas/instrumentação , Humanos
6.
J Shoulder Elbow Surg ; 23(8): 1099-106, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24496050

RESUMO

BACKGROUND: This study investigated the histopathology of the long head of biceps (LHB) tendon and correlated the findings with the macroscopic appearances of the LHB and the size of rotator cuff tears (RCTs) in patients with chronic RCTs. METHODS: We compared biopsy specimens from LHBs in 34 patients with chronic RCTs and grossly normal LHBs in 8 patients undergoing shoulder hemiarthroplasty (controls). Duration of preoperative symptoms, the severity of RCTs, and macroscopic appearance of LHBs were recorded, classified, and compared with the histologic grading and apoptosis index of terminal deoxynucleotide transferase-mediated biotin-deoxy uridine triphosphate nick-end labeling (TUNEL) assays of LHBs. RESULTS: In the RCT group, there were 8 partial-thickness tears with 5 macroscopic LHB lesions, 12 full-thickness tears with 8 macroscopic LHB lesions, and 14 massive tears with 13 macroscopic LHB lesions. There were 6 LHB subluxations. However, the macroscopic grading and the symptom duration were not correlated with the severity of the histology. In patients with massive tears, no matter what the macroscopic appearance of the LHB, the proportion of end-stage (grade 4) histologic LHB tendinopathy significantly increased (85.7%, P < .05) compared with patients with other types of RCTs. There was a consistently high incidence of advanced LHB histology (grade 3 or higher) in each classification of RCTs (75.0%-100.0%). The 8 patients in the control group showed milder histopathology (grade 1 or 2). The apoptosis index significantly increased as the tendinopathy progressed (P < .05). CONCLUSIONS: The macroscopic pathology of LHB may not fully reflect the severity of tendinopathy, and the coexisting size of RCTs plays a role in the severity of LHB tendinopathy.


Assuntos
Traumatismos do Braço/patologia , Manguito Rotador/patologia , Tendinopatia/patologia , Idoso , Doença Crônica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Manguito Rotador/cirurgia , Lesões do Manguito Rotador
7.
J Radiol Prot ; 34(4): 801-9, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25325378

RESUMO

Patients with developmental dysplasia of the hip (DDH) generally undergo multiple x-ray examinations of both hip joints. During these examinations, the gonads are completely exposed to radiation, unless shielded. Although many types and sizes of gonad shields exist, they often do not provide adequate protection because of size and placement issues; additionally, these shields are frequently omitted for female patients. Our aim was to assess gonad protection during x-ray examination that is provided by gonad shields designed for individual female patients with DDH.We retrospectively retrieved data from the Picture Archiving and Communication System database; pelvic plain x-ray films from 766 females, 18 years old or younger, were included in our analysis. Based on x-ray measurements of the anterior superior iliac spine, we developed a system of gonad shield design that depended on the distance between anterior superior iliac spine markers. We custom-made shields and then examined shielding rates and shielding accuracy before and after these new shields became available. Standard (general-purpose) shields were used before our custom design project was implemented. The shielding rate and shielding accuracy were, respectively, 14.5% and 8.4% before the project was implemented and 72.7% and 32.2% after it was implemented. A shield that is more anatomically correct and available in several different sizes may increase the likelihood of gonad protection during pelvic x-ray examinations.


Assuntos
Artrografia/instrumentação , Luxação Congênita de Quadril/diagnóstico por imagem , Tratamentos com Preservação do Órgão/instrumentação , Órgãos em Risco/efeitos da radiação , Ovário/efeitos da radiação , Proteção Radiológica/instrumentação , Adolescente , Artrografia/estatística & dados numéricos , Carga Corporal (Radioterapia) , Criança , Pré-Escolar , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Lactente , Recém-Nascido , Tratamentos com Preservação do Órgão/métodos , Segurança do Paciente , Doses de Radiação , Proteção Radiológica/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
8.
Eur J Radiol ; 170: 111201, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38042022

RESUMO

BACKGROUND: Traditional treatment for displaced humeral supracondylar fractures (SCFs) in children involves closed reduction (CR) under fluoroscopic guidance, percutaneous pinning, and immobilization with a long-arm cast. This study aims to explore the viability of using radiation-free ultrasound (US) for guiding CR and tracking ulnar nerve dynamics during medial pinning, contrasting the US method with the conventional cross pinning technique. MATERIALS AND METHODS: We assessed 70 children with acute displaced SCFs. The US group (n = 30) underwent US-guided reduction, whereas the traditional group (n = 40) underwent fluoroscopy-guided reduction. Both groups received percutaneous cross pinning and subsequent cast immobilization. Postoperative outcomes were compared between the two methods after a 6-month follow-up. In the US group, ultrasonography assessed fracture displacement distances before and after CR. The angle at which the ulnar nerve relocated to the cubital tunnel during elbow extension was documented using real-time US monitoring during medial pinning. RESULTS: The US group demonstrated improved reduction accuracy, increased range of motion, superior restoration of both Baumann and Humeroulnar angles, and a decreased incidence of malunions compared to the traditional group (all p < 0.05). The ultrasonographic measurement of fracture displacement was comparable with that of fluoroscopy (intraclass correlation coefficient > 0.90). In the US group, no ulnar nerve injury was noted, compared to 2.5 % in the traditional group, and real-time US observations revealed ulnar nerve hypermobility, with 53.3 % of patients exhibiting anterior ulnar nerve subluxation at 120° elbow flexion, 40 % at 90°, 16.7 % at 60°, and none at 30° flexion. CONCLUSION: Ultrasound is as reliable as fluoroscopy for evaluating fracture reductions. The use of intra-operative ultrasound significantly improves reduction accuracy and radiographic outcomes while reducing the risk of ulnar nerve injury.


Assuntos
Fraturas do Úmero , Luxações Articulares , Humanos , Criança , Nervo Ulnar/diagnóstico por imagem , Pinos Ortopédicos , Fraturas do Úmero/diagnóstico por imagem , Fraturas do Úmero/cirurgia , Úmero , Ultrassonografia , Resultado do Tratamento , Estudos Retrospectivos , Fixação Interna de Fraturas/métodos
9.
J Bone Joint Surg Am ; 106(4): 356-367, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38015923

RESUMO

BACKGROUND: Clubfoot, or congenital talipes equinovarus deformity, is a common anomaly affecting the foot in infants. However, clinical equipoise remains between different interventions, especially those based on the Ponseti method. The aim of this study was to examine the clinical outcomes of the various interventions for treating idiopathic clubfoot. METHODS: Searches of the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, Embase, Scopus, and CINAHL were conducted. Randomized controlled trials comparing different interventions, including the Ponseti method, accelerated Ponseti method, Ponseti method with botulinum toxin type A (Botox) injection, Ponseti method with early tibialis anterior tendon transfer (TATT), Kite method, and surgical treatment, were included. Network meta-analyses (NMAs) were conducted according to the PRISMA (Preferred Reporting Items for Systematic reviews and Meta-Analyses) reporting guidelines. The primary outcomes were the change in total Pirani score and maximal ankle dorsiflexion. Secondary outcomes were the number of casts, time in casts, and rates of tenotomy, total complications, relapse, adverse events, and additional required major surgery. RESULTS: Eleven randomized controlled trials involving 740 feet were included. According to the SUCRA (surface under the cumulative ranking curve)-based relative ranking, the Ponseti method was associated with the best outcomes in terms of Pirani score changes, maximal ankle dorsiflexion, number of casts, adverse events, and total complications, whereas the accelerated Ponseti method was associated with the best outcomes in terms of time in casts and tenotomy rate. Early TATT ranked best in terms of relapse rate. The Ponseti method with Botox injection was associated with the best outcomes in terms of the need for additional major surgery. CONCLUSIONS: The NMAs suggest that the Ponseti method is the optimal treatment overall, despite potential drawbacks such as longer time in casts and higher rates of tenotomy, relapse, and the need for additional surgery compared with other modified approaches. Therefore, clinicians should consider how treatments can be tailored individually. LEVEL OF EVIDENCE: Therapeutic Level I . See Instructions for Authors for a complete description of levels of evidence.


Assuntos
Tendão do Calcâneo , Toxinas Botulínicas Tipo A , Pé Torto Equinovaro , Lactente , Humanos , Pé Torto Equinovaro/cirurgia , Pé Torto Equinovaro/tratamento farmacológico , Metanálise em Rede , Toxinas Botulínicas Tipo A/uso terapêutico , Resultado do Tratamento , Ensaios Clínicos Controlados Aleatórios como Assunto , Tenotomia/métodos , Tendão do Calcâneo/cirurgia , Recidiva , Moldes Cirúrgicos
10.
Children (Basel) ; 11(4)2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38671703

RESUMO

This case report sheds light on the management of skeletal deformity in a young child with X-linked hypophosphatemia (XLH), emphasizing the significance of a timely orthotic intervention alongside pharmacological treatment, which is a strategy not frequently highlighted in the XLH literature. The patient, a 2-year-and-7-month-old female, presented with classic XLH symptoms, including short stature, pronounced genu varum, and hypophosphatemia, with deformities observed in both the coronal and sagittal planes of the femur and tibia. Despite initial reliance on pharmacotherapy, which proved insufficient for skeletal realignment, the integration of orthotic treatment at age 3 marked a pivotal turn in the management strategy. By the age of 5 years and 9 months, this combined approach yielded significant improvements: the deformities in the femur and tibia were notably corrected, tibial torsion was addressed, and enhanced limb alignment was achieved, as corroborated by radiographic evidence. This case underscores the effectiveness of orthotic intervention as a critical and underemphasized adjunct to pharmacological therapy in managing XLH in early childhood. It advocates for the early inclusion of orthotic measures to optimize treatment outcomes and expand the range of management strategies for limb deformities.

11.
Sci Rep ; 13(1): 6891, 2023 04 27.
Artigo em Inglês | MEDLINE | ID: mdl-37105993

RESUMO

The multitude of fixation options for radial neck fractures, such as pins, screws, biodegradable pins and screws, locking plates, and blade plates, has led to a lack of consensus on the optimal implant choice and associated biomechanical properties. This study aims to evaluate the biomechanical strength of various fixation constructs in axial, sagittal, and torsional loading directions. We included biomechanical studies comparing different interventions, such as cross/parallel screws, nonlocking plates with or without augmented screws, fixed angle devices (T or anatomic locking plates or blade plates), and cross pins. A systematic search of MEDLINE (Ovid), Embase, Scopus, and CINAHL EBSCO databases was conducted on September 26th, 2022. Data extraction was carried out by one author and verified by another. A network meta-analysis (NMA) was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-analyses guidelines. Primary outcomes encompassed axial, bending, and torsional stiffness, while the secondary outcome was bending load to failure. Effect sizes were calculated for continuous outcomes, and relative treatment ranking was measured using the surface under the cumulative ranking curve (SUCRA). Our analysis encompassed eight studies, incorporating 172 specimens. The findings indicated that fixed angle constructs, specifically the anatomic locking plate, demonstrated superior axial stiffness (mean difference [MD]: 23.59 N/mm; 95% CI 8.12-39.06) in comparison to the cross screw. Additionally, the blade plate construct excelled in bending stiffness (MD: 32.37 N/mm; 95% CI - 47.37 to 112.11) relative to the cross screw construct, while the cross-screw construct proved to be the most robust in terms of bending load failure. The parallel screw construct performed optimally in torsional stiffness (MD: 139.39 Nm/degree; 95% CI 0.79-277.98) when compared to the cross screw construct. Lastly, the nonlocking plate, locking T plate, and cross-pin constructs were found to be inferior in most respects to alternative interventions. The NMA indicated that fixed angle devices (blade plate and anatomic locking plate) and screw fixations may exhibit enhanced biomechanical strength in axial and bending directions, whereas cross screws demonstrated reduced torsional stability in comparison to parallel screws. It is imperative for clinicians to consider the application of these findings in constraining forces across various directions during early range of motion exercises, taking into account the distinct biomechanical properties of the respective implants.


Assuntos
Fraturas da Cabeça e do Colo do Rádio , Fraturas do Rádio , Humanos , Fixação Interna de Fraturas , Metanálise em Rede , Parafusos Ósseos , Pinos Ortopédicos , Placas Ósseas , Fraturas do Rádio/cirurgia , Fenômenos Biomecânicos
12.
NMR Biomed ; 25(2): 359-68, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21793078

RESUMO

In vivo (1)H MRS is a noninvasive imaging technique for the identification of malignancy. Musculoskeletal lesions vary in their composition, causing field inhomogeneity and magnetic susceptibility effects which may be technical and diagnostic challenges for MRS. This study investigated the factors that affect diagnostic accuracy in the use of MRS for the characterization of musculoskeletal neoplasms. During a 7-year period, 210 consecutive patients with musculoskeletal lesions larger than 1.5 cm in diameter were examined. MRS of a single-voxel point-resolved spectroscopy sequence with TE = 135 ms was undertaken using a 1.5-T scanner. Lesions with a choline signal-to-noise ratio larger than 3.0 were considered to be malignant tumors. The diagnostic accuracy was calculated for all lesions and for subgroups on the basis of lesion type (bone and soft tissue), lesion composition (mixed and solid nonsclerotic), lesion size (≤4, >4-10 and >10 cm), MR scanner (MR scanner 1 and 2) and selected voxel size (≤3, >3-8 and >8 cm(3)). Multivariate logistic regressions were performed to estimate the associations between each factor and diagnostic accuracy. The diagnostic accuracy was 73.3% for all lesions. The accuracy was 54.4% for mixed lesions and 80.4% for solid nonsclerotic lesions (p < 0.001). The diagnostic accuracy was lower for larger lesions [86.8% for lesions of ≤4 cm, 71.6% for lesions of >4-10 cm (p = 0.04) and 63.6% for lesions of >10 cm (p = 0.007)]. There was no difference in diagnostic accuracy for bone versus soft-tissue lesions or as a function of MR scanner or voxel size. By the use of multivariate logistic regression, a solid nonsclerotic lesion was 3.15 times (95% confidence interval, 1.59-6.27) more likely than a mixed lesion to have a diagnosis (p = 0.001). MRS can be used to characterize musculoskeletal lesions, particularly solid nonsclerotic lesions.


Assuntos
Espectroscopia de Ressonância Magnética/métodos , Sistema Musculoesquelético/patologia , Prótons , Neoplasias de Tecidos Moles/diagnóstico , Neoplasias de Tecidos Moles/patologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Valor Preditivo dos Testes , Neoplasias de Tecidos Moles/classificação , Adulto Jovem
13.
Hu Li Za Zhi ; 59(2): 72-9, 2012 Apr.
Artigo em Zh | MEDLINE | ID: mdl-22469894

RESUMO

BACKGROUND & PROBLEMS: The rate of allogenic blood preparation for an elective total knee arthroplasty (TKA) has been as high as 100% at our institute. However, most (76.2%) of these preparations were wasted. PURPOSE: This project worked to reduce unnecessary blood preparations for this elective procedure and reduce resource expenditures. RESOLUTIONS: Key issues identified as requiring resolution included: Uncertainty regarding urgent transfusion need, insufficient preoperative evaluation of high risk patients, and the use of outdated clinical pathways. Measures taken to overcome these issues included redefining transfusion triggers using relevant empirical data as conclusive evidence and building a general consensus within the medical team while acquiring practical support from decision makers. A more comprehensive assessment process for identifying risk factors was developed by reviewing and assessing the prior experiences of inpatients; New standard procedures for blood preparation and transfusion were issued; and related clinical pathways were updated with supplementary measures. RESULTS: After project implementation, the blood preparation rate declined significantly from 100% to 10.2%. The rate of effective transfusion rate rose from 23.8% to 76.2%. CONCLUSIONS: This project combined various medical professions to propose practical improvements that effectively access peer support. We recommend applying this model in all care units to ensure patient safety and lower medical costs while developing a more effective policy for blood transfusion.


Assuntos
Artroplastia do Joelho/métodos , Transfusão de Sangue , Humanos
14.
GMS Health Innov Technol ; 16: Doc02, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35360087

RESUMO

Medical technology is undergoing rapid transformations, and the classifications of medical devices have also expanded greatly; therefore, it is necessary to develop appropriate reimbursement policies and pricing mechanisms in a timely manner. This paper aims to introduce the reimbursement coverage and pricing rules for medical devices in Taiwan. In addition, this paper identifies and evaluates available health technology assessments (HTA) and literature on published websites concerning medical device decision-making processes and pricing systems in South Korea and Japan, which are near Taiwan and have similar reimbursement coverage processes. Reimbursement policy and pricing mechanisms are constantly being revised in Taiwan, Japan, and South Korea. Recently, all three countries attempted to establish new reimbursement coverage decision-making and pricing rules, adopting a differentiated approach based on the level of evidence required for the appropriated reimbursement in terms of a feasible evaluation mechanism for providing patients with more effective medical devices. This article is expected to contribute to providing references to new reimbursement coverage decision-making and pricing rules.

15.
Knee Surg Sports Traumatol Arthrosc ; 19(7): 1121-30, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21161177

RESUMO

PURPOSE: The use of an intraoperative tourniquet for total knee arthroplasty (TKA) is a common practice. However, the effectiveness and safety are still questionable. A systematic review was conducted to examine that whether using a tourniquet in TKA was effective without increasing the risk of complications. METHODS: A comprehensive literature search was done in PubMed Medicine, Embase, and other internet database. The review work and the following meta-analysis were processed to evaluate the role of tourniquet in TKA. RESULTS: Eight randomized controlled trials and three high-quality prospective studies involving 634 knees and comparing TKA with and without the use of a tourniquet were included in this analysis. The results demonstrated that using a tourniquet could decrease the measured blood loss but could not decrease the calculated blood loss, which indicated actual blood loss. Patients managed with a tourniquet might have higher risks of thromboembolic complications. Using the tourniquet with late release after wound closure could shorten the operation time; whereas early release did not show this benefit. CONCLUSIONS: The current evidence suggested that using tourniquet in TKA may save time but may not reduce the blood loss. Due to the higher risks of thromboembolic complications, we should use a tourniquet in TKA with caution.


Assuntos
Artroplastia do Joelho/métodos , Hemostasia Cirúrgica/instrumentação , Torniquetes , Perda Sanguínea Cirúrgica/prevenção & controle , Volume Sanguíneo , Humanos , Complicações Pós-Operatórias/epidemiologia , Tromboembolia/epidemiologia
16.
J Digit Imaging ; 23(3): 246-57, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19130132

RESUMO

The quality of ultrasound images is usually influenced by speckle noise and the temporal decorrelation of the speckle patterns. To reduce the speckle noise, compounding techniques have been widely applied. Partially correlated images scanned on the same subject cross-section are combined to generate a compound image with improved image quality. However, the compounding technique might introduce image blurring if the transducer or the target moves too fast. This blurring effect becomes especially critical when assessing tissue deformation in clinical motion examinations. In this paper, an ultrasound motion compounding system is proposed to improve the quality of ultrasound motion sequences. The proposed motion compounding technique uses a hierarchical adaptive feature weighted motion estimation method to realign the frames before compounding. Each frame is first registered and warped to the reference frame before being compounded to reduce the speckle noise. Experimental results showed that the motion could be assessed accurately and better visualization could be achieved for the compound images, with improved signal-to-noise and contrast-to-noise ratios.


Assuntos
Sensibilidades de Contraste , Aumento da Imagem , Ultrassonografia Doppler , Algoritmos , Humanos , Aumento da Imagem/métodos , Ultrassonografia Doppler/métodos
17.
J Chin Med Assoc ; 83(2): 156-163, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31834024

RESUMO

BACKGROUND: The relationship between certification for specific disease care and clinical outcome was not well known. Previous studies regarding the effect of certification for acute stroke centers were limited by their cross-sectional design. This study aimed to investigate the effect of disease-specific care (DSC) certification on healthcare performance and clinical outcome of acute myocardial infarction (AMI). METHODS: This retrospective, longitudinal, controlled study was performed by analyzing the nationwide Taiwan Clinical Performance Indicators dataset from 2011 to 2018. Hospitals undergoing DSC certification for coronary care and reporting AMI indicators 1 year before, during, and 1 year after certification were included in group C, whereas hospitals not seeking DSC certification but reporting AMI indicators during the same period were included in group U. The primary endpoint was in-hospital mortality of AMI. RESULTS: In total, 20 hospitals (9 in group C and 11 in group U) and up to 16 173 AMI cases were included for analysis. In-hospital mortality was similar between both groups at baseline. However, the in-hospital mortality was significantly improved during and after certification periods in comparison with that at baseline in group C (6.8% vs 8.4%, p = 0.04; 6.7% vs 8.4%, p = 0.02), whereas there was no significant change in group U, resulting in a statistically significant difference between both groups during and after certification periods (odds ratio = 0.74 [95% CI = 0.60-0.91] and 0.78 [95% CI = 0.64-0.96]). Compared with group U, the improvement in healthcare performance indicators, such as door-to-electrocardiography time <10 minutes, blood testing for low-density lipoprotein cholesterol level, prescribing a beta-blockade or a P2Y12 receptor inhibitor during hospitalization, prescribing a statin on discharge, and consultation for cardiac rehabilitation, was significant in group C. CONCLUSION: The current study demonstrated the beneficial effect of DSC certification on clinical outcome of AMI probably mediated through quality improvement during the healthcare process.


Assuntos
Certificação , Infarto do Miocárdio/terapia , Atenção à Saúde/normas , Mortalidade Hospitalar , Humanos , Estudos Longitudinais , Infarto do Miocárdio/mortalidade , Melhoria de Qualidade , Estudos Retrospectivos
20.
Ci Ji Yi Xue Za Zhi ; 29(1): 37-40, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28757762

RESUMO

Fixation of comminuted or osteoporotic fractures in the proximal humerus is a challenge for orthopedic surgeons. In the past two decades, locking plates have been used for proximal humeral fracture fixation. However, complications such as loss of reduction have been reported, and the implants are not always available in some regions. Therefore, we describe an alternative procedure involving fixation with a nonlocking cloverleaf plate augmented with tension wiring to provide adequate stability and prevent loss of reduction.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA