Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Bone Jt Open ; 5(2): 132-138, 2024 02 13.
Artigo em Inglês | MEDLINE | ID: mdl-38346449

RESUMO

Aims: The primary aim of this study was to report the radiological outcomes of patients with a dorsally displaced distal radius fracture who were randomized to a moulded cast or surgical fixation with wires following manipulation and closed reduction of their fracture. The secondary aim was to correlate radiological outcomes with patient-reported outcome measures (PROMs) in the year following injury. Methods: Participants were recruited as part of DRAFFT2, a UK multicentre clinical trial. Participants were aged 16 years or over with a dorsally displaced distal radius fracture, and were eligible for the trial if they needed a manipulation of their fracture, as recommended by their treating surgeon. Participants were randomly allocated on a 1:1 ratio to moulded cast or Kirschner wires after manipulation of the fracture in the operating theatre. Standard posteroanterior and lateral radiographs were performed in the radiology department of participating centres at the time of the patient's initial assessment in the emergency department and six weeks postoperatively. Intraoperative fluoroscopic images taken at the time of fracture reduction were also assessed. Results: Patients treated with surgical fixation with wires had less dorsal angulation of the radius versus those treated in a moulded cast at six weeks after manipulation of the fracture; the mean difference of -4.13° was statistically significant (95% confidence interval 5.82 to -2.45). There was no evidence of a difference in radial shortening. However, there was no correlation between these radiological measurements and PROMs at any timepoint in the 12 months post-injury. Conclusion: For patients with a dorsally displaced distal radius fracture treated with a closed manipulation, surgical fixation with wires leads to less dorsal angulation on radiographs at six weeks compared with patients treated in a moulded plaster cast alone. However, the difference in dorsal angulation was small and did not correlate with patient-reported pain and function.

2.
J Foot Ankle Surg ; 47(4): 273-7, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18590887

RESUMO

We prospectively reviewed 22 patients (31 feet) who underwent a scarf osteotomy between January 2001 and March 2002. There were 20 females and 2 males. Ages ranged from 35 to 77 years (mean = 57 years). American Orthopedic Foot and Ankle Society (AOFAS) scores improved from a preoperative mean of 47.94 +/- 13.57 and increased significantly to 96.10 +/- 6.15 (P < .01) after 12 months. The hallux valgus angle improved in all patients from a preop mean of 31.4 +/- 8.0 degrees to 11.0 +/- 10.8 degrees at 12 months. The intermetatarsal angle improved from 13.0 +/- 4.2 degrees to 6.1 +/- 3.2 degrees. All of these changes were significant. Bony union was achieved in all patients. There were no significant changes in peak pressure, pressure/time, or force/time pedobarography noted after 12 months. Significant improvement in pain scores from preoperative mean of 21.29 +/- 11.0 to 32.90 +/- 9.57 at 5 years (P < .01) was noted and 90.9% of patients remained satisfied with the operation and would recommend the procedure. There were 2 complications. One patient experienced a traumatic neuroma and another avascular necrosis of the first metatarsal head. The scarf osteotomy is a safe and effective procedure with reproducible and excellent medium-term results.


Assuntos
Hallux Valgus/cirurgia , Osteotomia/métodos , Adulto , Idoso , Feminino , Hallux Valgus/diagnóstico por imagem , Inquéritos Epidemiológicos , Humanos , Masculino , Metatarso/cirurgia , Pessoa de Meia-Idade , Osteotomia/instrumentação , Estudos Prospectivos , Radiografia , Inquéritos e Questionários , Fatores de Tempo , Resultado do Tratamento
3.
J Hand Surg Eur Vol ; 43(8): 808-812, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29871567

RESUMO

We conducted a prospective randomized controlled trial to investigate carpal tunnel decompression under local anaesthesia. Carpal tunnel decompression was performed in 37 wrists using local anaesthesia and an arm tourniquet and 36 without tourniquet but with a local anaesthetic mixture containing adrenaline. Patients who underwent carpal tunnel decompression using a tourniquet experienced a significantly greater degree of pain when compared with those who did not have a tourniquet. Pain and hand function improved to a similar degree in both groups. We conclude that carpal tunnel decompression performed with a tourniquet causes patients unnecessary pain with no additional benefit as compared with the wide-awake carpal tunnel decompression without use of a tourniquet. LEVEL OF EVIDENCE: I.


Assuntos
Anestesia Local , Síndrome do Túnel Carpal/cirurgia , Descompressão Cirúrgica , Dor/etiologia , Torniquetes , Anestésicos Locais/administração & dosagem , Avaliação da Deficiência , Epinefrina/administração & dosagem , Feminino , Humanos , Complicações Intraoperatórias , Lidocaína/administração & dosagem , Masculino , Pessoa de Meia-Idade , Dor/prevenção & controle , Vasoconstritores/administração & dosagem , Escala Visual Analógica
4.
Injury ; 46(12): 2389-93, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26482482

RESUMO

Reverse oblique intertrochanteric fractures have unique mechanical characteristics and are often treated with intramedullary implants. We compared the outcomes of the reconstruction trochanteric antegrade nail (TAN) with the proximal femoral nail antirotation (PFNA). Between July 2008 and February 2014, we reviewed all patients with reverse oblique intertrochanteric fractures treated at our hospital. Patients with pathological fractures and those who were treated with other than TAN and PFNA nailing systems were excluded. Preoperative assessment included the Abbreviated mental test score (AMT), the ASA grade, pre-injury mobility and place of residence. Postoperative outcome measures included the type of implant used, time to fracture union, failures of fixation and revision surgeries. Fifty-eight patients were included and divided into two groups based on the treatment: 22 patients treated with TAN and 36 patients treated with PFNA systems. The two groups were well matched with regards to demographics and fracture type. The overall union rate was similar in both groups but the time to union was shorter in the TAN group. There were 8 implant failures in the PFNA (22.2%) group compare to none in the TAN group. Implant failure was associated with the severity of fracture (AO 31.A3.3) but was not related to fracture malreduction or screw position (Tip-apex-distance). Our study suggests that the use of reconstruction system with two screws such as TAN may be more suitable implant for reverse oblique intertrochanteric hip fractures.


Assuntos
Fixação Intramedular de Fraturas , Fraturas do Quadril/cirurgia , Articulação do Quadril/cirurgia , Complicações Pós-Operatórias/cirurgia , Reoperação/estatística & dados numéricos , Idoso , Idoso de 80 Anos ou mais , Pinos Ortopédicos , Feminino , Seguimentos , Fixação Intramedular de Fraturas/efeitos adversos , Fixação Intramedular de Fraturas/instrumentação , Fixação Intramedular de Fraturas/métodos , Consolidação da Fratura , Fraturas do Quadril/diagnóstico por imagem , Fraturas do Quadril/fisiopatologia , Articulação do Quadril/fisiopatologia , Humanos , Masculino , Duração da Cirurgia , Avaliação de Processos e Resultados em Cuidados de Saúde , Estudos Retrospectivos , Rotação
5.
Foot Ankle Clin ; 16(1): 165-79, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21338937

RESUMO

Massive bone loss following calcaneal fractures is a challenging condition to treat, especially if nonunion is present. Meticulous preoperative examination and imaging are crucial for accurate preoperative planning. If performed, successful outcomes can be achieved with the strategies outlined in this article.


Assuntos
Artrodese/métodos , Reabsorção Óssea/cirurgia , Calcâneo/lesões , Fraturas Ósseas/complicações , Fraturas Mal-Unidas/complicações , Articulações Tarsianas , Reabsorção Óssea/diagnóstico , Reabsorção Óssea/etiologia , Fraturas Ósseas/diagnóstico , Fraturas Ósseas/cirurgia , Fraturas Mal-Unidas/diagnóstico , Fraturas Mal-Unidas/cirurgia , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA