Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
J Appl Clin Med Phys ; : e14509, 2024 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-39238193

RESUMO

BACKGROUND: Brachytherapy (BT) treatments involving temporary high-dose rate (HDR) sources are extensively employed in clinical practice. Ensuring the consistency of all measurement equipment at the hospital level is crucial, requiring a robust redundancy and consistency program. This enables the institution to verify the stability of the dosimetry system over time. PURPOSE: To describe, justify, and analyze a component of the redundancy program of the calibration protocols followed by the Radiotherapy Department of the Hospital Universitari i Politècnic La Fe (València, Spain) during the last 10 years for the case of HDR BT as an additional component to ensure long term stability of the measurement equipment. METHODS: At the time the HDR BT source is replaced, its Air Kerma Strength (SK) is measured. By comparing this value with the one obtained at the time of installation (corrected by decay), a clear determination of the stability of the measurement equipment can be performed. RESULTS: Difference between SK,vendor and SK,hosp as a function of the measurement date is reported for a 10 years' period. All measurements are well within the ±3% tolerance level recommended in current international guidelines. Percentage differences of SK,hosp values at the time of replacement compared to SK,hosp ones at the time when the source was installed are within the ±0.5% range, reflecting oscillations around a null deviation. CONCLUSIONS: The method proposed allows any hospital to ensure a redundancy component of the long-term stability of all equipment involved in BT measurements in a very simple and time efficient manner. Additionally, it enables the hospital to maintain a detailed log of historical differences, facilitating the identification and correction of potential systematic deviations over time.

2.
Rep Pract Oncol Radiother ; 26(1): 119-127, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34046222

RESUMO

BACKGROUND: Utilization of stereotactic radiosurgery (SRS) for brain metastases (BM) has become the technique of choice as opposed to whole brain radiation therapy (WBRT). The aim of this work is to evaluate the feasibility and potential benefits in terms of normal tissue (NT) and dose escalation of volumetric modulated arc therapy (VMAT) in SRS metastasis treatment. A VMAT optimization procedure has therefore been developed for internal dose scaling which minimizes planner dependence. MATERIALS AND METHODS: Five patient-plans incorporating treatment with frame-based SRS with dynamic conformal arc technique (DA) were re-planned for VMAT. The lesions selected were between 4-6 cm3. The same geometry used in the DA plans was maintained for the VMAT cases. A VMAT planning procedure was performed attempting to scale the dose in inner auxiliary volumes, and to explore the potential for dose scaling with this technique. Comparison of dose-volume histogram (DVH) parameters were obtained. RESULTS: VMAT allows a superior NT sparing plus conformity and dose scaling using the auxiliary volumes. The VMAT results were significantly superior in NT sparing, improving both the V10 and V12 values in all cases, with a 2-3 cm3 saving. In addition, VMAT improves the dose coverage D95 by about 0.5 Gy. The objective of dose escalation was achieved with VMAT with an increment of the Dmean and the Dmedian of about 2 Gy. CONCLUSIONS: This work shows a benefit of VMAT in SRS treatment with significant NT sparing. A VMAT optimization procedure, based on auxiliary inner volumes, has been developed, enabling internal dose escalation.

3.
J Radiosurg SBRT ; 9(2): 113-120, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39087056

RESUMO

The aim of this work was to evaluate the inter- and intra-observer variation in contouring vestibular schwannoma (VS) and the organs-at-risk (OAR), and its dosimetric impact in Volumetric Modulated Arc Therapy (VMAT). Three VS typical cases were contoured by four clinicians. The Agreement Volume Index (AVI) appeared to be notably higher in VS than in OARs, such that the dose coverage of VS is fairly robust. In OARs, the largest variation was +1.02Gy in dmax for the brainstem, +0.78Gy in dmean for the cochlea and +1.05Gy in dmax of the trigeminal nerve. Accordingly, it was decided that all VS delineations for stereotactic radiosurgery (SRS), and all frame-based SRS contouring in general, should always be reviewed by a second physician. In addition, the retrospective presentation of VS cases at daily peer review meetings has also been adopted to ensure that the consensus is constantly updated, as well as for training purposes.

4.
J Appl Clin Med Phys ; 13(2): 3667, 2012 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-22402383

RESUMO

A new titanized breast mesh, TiLOOP Bra, is currently available for implantation in patients who require radiotherapy. The purpose of this work is to study the dosimetric effect of the presence of a TiLOOP Bra mesh on breast radiation treatment and radiographic imaging. The dosimetric effects have been measured for three X-ray energies: 1.25 MeV, 6 MV and 18 MV, using radiochromic films placed at three different depths. These depths are representative of mesh location in breast during the radiotherapy treatment and hence, are of interest in this study. In order to assess the disturbance in a radiographic image, different computed tomographic (CT) studies of the mesh have been performed. The absorbed dose differences with and without the mesh are less than 1%. No metallic artifacts have been observed in radiographic images associated with the mesh, nor significant disturbances in Hounsfield Units. The TiLOOP Bra mesh does not disturb the dosimetry of a typical radiotherapy treatment and its influence in the quality of the CT scan required for planning is negligible.


Assuntos
Implantes de Mama , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/radioterapia , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Planejamento da Radioterapia Assistida por Computador , Telas Cirúrgicas , Tomografia Computadorizada por Raios X , Neoplasias da Mama/patologia , Feminino , Humanos , Imagens de Fantasmas , Dosagem Radioterapêutica
5.
J Radiosurg SBRT ; 8(4): 283-290, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-37416332

RESUMO

Purpose: In the implementation of the use of EncompassTM partially open immobilization mask to perform SRS of multiple brain metastasis, the evaluation of patient's intrafraction motion (IM) is deemed convenient to verify that the margins applied to the GTV are able to ensure adequate dose coverage to each lesion. Methods: IM was determined by comparing the pre- and post-treatment CBCT images with respect to the simulation CT for a total of 23 fractions. The dosimetric impact on GTV coverage due to translational errors in patient positioning and rotational uncertainties of LINAC's performance was also evaluated. Results: The absolute magnitude of IM was less than 1 mm in all cases. The dosimetric difference on GTV coverage due to patient's IM was inferior to 5%. There was not found any significant correlation between the dosimetric impact of rotational uncertainties with the distance to the isocenter. Conclusion: The margins applied to the GTV are adequate when using EncompassTM immobilization device.

6.
J Contemp Brachytherapy ; 12(2): 139-146, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32395138

RESUMO

PURPOSE: The ICRU 89 recommends reporting a set of vaginal dose points for cervical cancer treatments in order to quantify the goodness of implant. This vaginal dose reporting method for combined external beam radiotherapy and brachytherapy has been adopted by the EMBRACE II study protocol. Large variations in dose between patients and centers have been reported. The aim of this study was to determine possible discrepancies with consensus observers from the same institution. Therefore, the inter- and intra-observer variability were analyzed. MATERIAL AND METHODS: For five patients, five experienced observers reported dose at the proposed vaginal points twice. The effect of inter- and intra-observer variations on total dose was analyzed by estimating biologically equivalent dose EQD2 (α/ß = 3 Gy). Coefficient of variation (CV) was used to provide a measure of data dispersion as a proportion to the mean. RESULTS: The maximum inter-observer deviation among all patients and all points ranged from 0.5 Gy to 24.1 Gy in EQD2. The higher inter-observer discrepancies were found at points at 3 o'clock and at 6 o'clock, with respect to ovoids. In case of the maximum intra-observer deviation, it ranged from 0.5 Gy to 14.2 Gy, with higher deviation points at 12 o'clock and 9 o'clock, with respect to ovoids. CONCLUSIONS: There is a need to ensure consistency in vaginal points reporting. The impact of the dosimetric inter- and intra-observer variability should also be considered when dealing with dose tolerances and limits due to the potential dose gradient.

7.
J Contemp Brachytherapy ; 8(6): 518-524, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28115958

RESUMO

PURPOSE: Esteya® (Nucletron, an Elekta company, Elekta AB, Stockholm, Sweden) is an electronic brachytherapy device used for skin cancer lesion treatment. In order to establish an adequate level of quality of treatment, a risk analysis of the Esteya treatment process has been done, following the methodology proposed by the TG-100 guidelines of the American Association of Physicists in Medicine (AAPM). MATERIAL AND METHODS: A multidisciplinary team familiar with the treatment process was formed. This team developed a process map (PM) outlining the stages, through which a patient passed when subjected to the Esteya treatment. They identified potential failure modes (FM) and each individual FM was assessed for the severity (S), frequency of occurrence (O), and lack of detection (D). A list of existing quality management tools was developed and the FMs were consensually reevaluated. Finally, the FMs were ranked according to their risk priority number (RPN) and their S. RESULTS: 146 FMs were identified, 106 of which had RPN ≥ 50 and 30 had S ≥ 7. After introducing the quality management tools, only 21 FMs had RPN ≥ 50. The importance of ensuring contact between the applicator and the surface of the patient's skin was emphasized, so the setup was reviewed by a second individual before each treatment session with periodic quality control to ensure stability of the applicator pressure. Some of the essential quality management tools are already being implemented in the installation are the simple templates for reproducible positioning of skin applicators, that help marking the treatment area and positioning of X-ray tube. CONCLUSIONS: New quality management tools have been established as a result of the application of the failure modes and effects analysis (FMEA) treatment. However, periodic update of the FMEA process is necessary, since clinical experience has suggested occurring of further new possible potential failure modes.

8.
Radiother Oncol ; 77(2): 216-9, 2005 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-16226817

RESUMO

In this study, the dose rate distributions produced by low dose rate Cs-137 sources loaded in afterloadable dome applicators are studied using the Monte Carlo method. Dose differences between Monte Carlo results and calculations done using the superposition principle are within 1-3% in front of the applicator and between 3 and 10% near and along the longitudinal source axis. Consequently, the real doses to lateral vaginal wall, rectum and bladder are very close to the doses estimated applying the superposition principle, while the dose to the vaginal cuff has been overestimated by up to 10%.


Assuntos
Braquiterapia/métodos , Método de Monte Carlo , Planejamento da Radioterapia Assistida por Computador/instrumentação , Braquiterapia/instrumentação , Relação Dose-Resposta à Radiação , Desenho de Equipamento , Segurança de Equipamentos , Humanos , Dose Máxima Tolerável , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Sensibilidade e Especificidade
9.
J Contemp Brachytherapy ; 3(1): 32-35, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27877198

RESUMO

PURPOSE: The Valencia HDR applicators are accessories of the microSelectron HDR afterloading system (Nucletron) shaped as truncated cones. The base of the cone is either 2 or 3 cm diameter. They are intended to treat skin lesions, being the typical prescription depth 3 mm. In patients with eyelid lesions, an internal shielding is very useful to reduce the dose to the ocular globe. The purpose of this work was to evaluate the dose enhancement from potential backscatter and electron contamination due to the shielding. MATERIAL AND METHODS: Two methods were used: a) Monte Carlo simulation, performed with the GEANT4 code, 2 cm Valencia applicator was placed on the surface of a water phantom in which 2 mm lead slab was located at 3 mm depth; b) radiochromic EBT films, used to verify the Monte Carlo results, positioning the films at 1.5, 3, 5 and 7 mm depth, inside the phantom. Two irradiations, with and without the lead shielding slab, were carried out. RESULTS: The Monte Carlo results showed that due to the backscatter component from the lead, the dose level raised to about 200% with a depth range of 0.5 mm. Under the lead the dose level was enhanced to about 130% with a depth range of 1 mm. Two millimeters of lead reduce the dose under the slab with about 60%. These results agree with film measurements within uncertainties. CONCLUSIONS: In conclusion, the use of 2 mm internal lead shielding in eyelid skin treatments with the Valencia applicators were evaluated using MC methods and EBT film dosimetry. The minimum bolus thickness that was needed above and below the shielding was 0.5 mm and 1 mm respectively, and the shielding reduced the absorbed dose delivered to the ocular globe by about 60%.

10.
J Contemp Brachytherapy ; 3(3): 121-4, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23346120

RESUMO

PURPOSE: The common use of nomograms in Low Dose Rate (LDR) permanent prostate brachytherapy (BT) allows to estimate the number of seeds required for an implant. Independent dosimetry verification is recommended for each clinical dosimetry in BT. Also, nomograms can be useful for dose calculation quality assurance and they could be adapted to High Dose Rate (HDR). This work sets nomograms for LDR and HDR prostate-BT implants, which are applied to three different institutions that use different implant techniques. MATERIAL AND METHODS: Patients treated throughout 2010 till April 2011 were considered for this study. This example was chosen to be the representative of the latest implant techniques and to ensure consistency in the planning. A sufficient number of cases for both BT modalities, prescription dose and different work methodology (depending on the institution) were taken into account. The specific nomograms were built using the correlation between the prostate volume and some characteristic parameters of each BT modality, such as the source Air Kerma Strength, number of implanted seeds in LDR or total radiation time in HDR. RESULTS: For each institution and BT modality, nomograms normalized to the prescribed dose were obtained and fitted to a linear function. The parameters of the adjustment show a good agreement between data and the fitting. It should be noted that for each institution these linear function parameters are different, indicating that each centre should construct its own nomograms. CONCLUSIONS: Nomograms for LDR and HDR prostate brachytherapy are simple quality assurance tools, specific for each institution. Nevertheless, their use should be complementary to the necessary independent verification.

11.
J Contemp Brachytherapy ; 2(3): 129-133, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27853474

RESUMO

PURPOSE: In this work a spreadsheet based program is presented that to a large extent independently verifies the calculations of individual plans of brachytherapy treatment planning systems for low dose rate, high dose rate and pulsed dose rate techniques. MATERIAL AND METHODS: The verification program has been developed based on workbooks/spreadsheets. The treatment planning system output text files are automatically loaded into the new program, allowing the use of the source coordinates, the desired calculation point coordinates, and the dwell times of a patient plan. The source strength and the reference dates are entered by the user and then dose points calculations are independently performed. The program shows its results in a comparison of its calculated point dose data with the corresponding TPS outcome. RESULTS: Results of 250 clinical cases show agreement with the TPS outcome within a 2% level. CONCLUSIONS: The program allows the implementation of the recommendations to verify the clinical brachytherapy dosimetry in a simple and accurate way, in only few minutes and with a minimum of user interactions.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA