Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Radiology ; 299(3): 494-507, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33904776

RESUMO

Acknowledging the increasing number of studies describing the use of whole-body MRI for cancer screening, and the increasing number of examinations being performed in patients with known cancers, an international multidisciplinary expert panel of radiologists and a geneticist with subject-specific expertise formulated technical acquisition standards, interpretation criteria, and limitations of whole-body MRI for cancer screening in individuals at higher risk, including those with cancer predisposition syndromes. The Oncologically Relevant Findings Reporting and Data System (ONCO-RADS) proposes a standard protocol for individuals at higher risk, including those with cancer predisposition syndromes. ONCO-RADS emphasizes structured reporting and five assessment categories for the classification of whole-body MRI findings. The ONCO-RADS guidelines are designed to promote standardization and limit variations in the acquisition, interpretation, and reporting of whole-body MRI scans for cancer screening. Published under a CC BY 4.0 license Online supplemental material is available for this article.


Assuntos
Imageamento por Ressonância Magnética/métodos , Oncologia/métodos , Neoplasias/diagnóstico por imagem , Imagem Corporal Total/métodos , Detecção Precoce de Câncer , Humanos
2.
Magn Reson Med ; 85(6): 3434-3446, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33404129

RESUMO

PURPOSE: To prospectively investigate the impact of image reconstruction on MRI radiomics features. METHODS: An anthropomorphic phantom was scanned at 1.5 T using a standardized sequence for MR-guided radiotherapy under SENSE and compressed-SENSE reconstruction settings. A total of 93 first-order and texture radiomics features in 10 volumes of interest were assessed based on (1) accuracy measured by the percentage deviation from the reference, (2) robustness on reconstruction in all volumes of interest measured by the intraclass correlation coefficient, and (3) repeatability measured by the coefficient of variance over the repetitive acquisitions. Finally, reliable and unreliable radiomics features were comprehensively determined based on their accuracy, robustness, and repeatability. RESULTS: Better accuracy and robustness of the radiomics features were achieved under SENSE than compressed-SENSE reconstruction. The feature accuracy under SENSE reconstruction was more affected by acceleration factor than direction, whereas under compressed-SENSE reconstruction, accuracy was substantially impacted by the increasing denoising levels. Feature repeatability was dependent more on feature types than on reconstruction. A total of 45 reliable features and 13 unreliable features were finally determined for SENSE, compared with 22 reliable and 26 unreliable features for compressed SENSE. First-order and gray-level co-occurrence matrix features were generally more reliable than other features. CONCLUSION: Radiomics features could be substantially affected by MRI reconstruction, so precautions need to be taken regarding their reliability for clinical use. This study helps the guidance of the preselection of reliable radiomics features and the preclusion of unreliable features in MR-guided radiotherapy.


Assuntos
Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Imagens de Fantasmas , Reprodutibilidade dos Testes
3.
Acta Radiol ; 59(3): 257-265, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28679324

RESUMO

Background Recent researches suggest that T1rho may be a non-invasive and quantitative technique for detecting and grading liver fibrosis. Purpose To compare a multi-breath-hold bright-blood fast gradient echo (GRE) imaging and a single breath-hold single-shot fast spin echo (FSE) imaging with black-blood effect for liver parenchyma T1rho measurement and to study liver physiological T1rho value in healthy volunteers. Material and Methods The institutional Ethics Committee approved this study. 28 healthy participants (18 men, 10 women; age = 29.6 ± 5.1 years) underwent GRE liver T1rho imaging, and 20 healthy participants (10 men, 10 women; age = 36.9 ± 10.3 years) underwent novel black-blood FSE liver T1rho imaging, both at 3T with spin-lock frequency of 500 Hz. The FSE technique allows simultaneous acquisition of four spin lock times (TSLs; 1 ms, 10 ms, 30 ms, 50msec) in 10 s. Results For FSE technique the intra-scan repeatability intraclass correlation coefficient (ICC) was 0.98; while the inter-scan reproducibility ICC was 0.82 which is better than GRE technique's 0.76. Liver T1rho value in women tended to have a higher value than T1rho values in men (FSE: 42.28 ± 4.06 ms for women and 39.13 ± 2.12 ms for men; GRE: 44.44 ± 1.62 ms for women and 42.36 ± 2.00 ms for men) and FSE technique showed liver T1rho value decreased slightly as age increased. Conclusion Single breath-hold black-blood FSE sequence has better scan-rescan reproducibility than multi-breath-hold bright-blood GRE sequence. Gender and age dependence of liver T1rho in healthy participants is observed, with young women tending to have a higher T1rho measurement.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Fígado/anatomia & histologia , Imageamento por Ressonância Magnética/métodos , Adulto , Fatores Etários , Suspensão da Respiração , Feminino , Humanos , Fígado/diagnóstico por imagem , Masculino , Valores de Referência , Reprodutibilidade dos Testes , Fatores Sexuais , Adulto Jovem
5.
AJR Am J Roentgenol ; 208(4): 761-769, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28177653

RESUMO

OBJECTIVE: The purpose of this study was to determine the prognostic value of myocardial perfusion CT for major adverse cardiac events (MACE). MATERIALS AND METHODS: Data from six centers in Asia, Europe, and North America on 144 patients with known or suspected coronary artery disease who had undergone coronary CT angiography (CCTA) and dynamic myocardial perfusion CT with a dual-source CT system were analyzed. CCTA studies were acquired at rest. Dynamic myocardial perfusion CT was performed under vasodilator stress. CCTA data were evaluated for the presence of coronary artery stenosis (≥ 50% luminal narrowing) on a per-vessel basis. Myocardial perfusion CT data were qualitatively evaluated for perfusion defects in each vessel territory. Patient follow-up was performed 6, 12, and 18 months after imaging. The prognostic value of CT findings was assessed with Kaplan-Meier statistics and the multivariate Cox proportional hazards regression model. RESULTS: According to the CCTA findings, 62 of 144 patients (43.1%) had at least one 50% or greater stenosis. According to the myocardial perfusion CT findings, 51 patients (35.4%) had one or more perfusion defects. Patients with at least one perfusion defect at myocardial perfusion CT were at increased risk of MACE (hazard ratio, 2.50; 95% CI, 1.34-4.65; p = 0.0040). This association remained significant after adjustment for age, sex, and clinical risk factors (hazard ratio, 2.41; 95% CI, 1.28-4.51; p = 0.0064) and after further adjustment for CCTA findings (hazard ratio, 2.03; 95% CI, 1.04-3.97; p = 0.0390). The number of territories with perfusion defects was strongly predictive of MACE with adjusted hazard ratios of 1.41, 3.44, and 4.76 for one, two, and three affected territories. CONCLUSION: In assessment for future MACE, myocardial perfusion CT has incremental predictive value over clinical risk factors and detection of coronary artery stenosis with CCTA.


Assuntos
Angiografia por Tomografia Computadorizada/estatística & dados numéricos , Angiografia Coronária/estatística & dados numéricos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Morte Súbita Cardíaca/epidemiologia , Imagem de Perfusão do Miocárdio/estatística & dados numéricos , Idoso , Ásia/epidemiologia , Europa (Continente)/epidemiologia , Teste de Esforço/estatística & dados numéricos , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , América do Norte/epidemiologia , Prevalência , Prognóstico , Reprodutibilidade dos Testes , Fatores de Risco , Sensibilidade e Especificidade , Taxa de Sobrevida
6.
J Comput Assist Tomogr ; 41(5): 679-687, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28708735

RESUMO

PURPOSE: The aim of this study was to evaluate the effect of the pseudohepatic anisotropy artifact on liver intravoxel incoherent motion (IVIM) metrics and whether the use of multiple gradient directions in the IVIM acquisition minimizes the artifact. MATERIALS AND METHODS: Multiple breath-holding and forced shallow free-breathing IVIM scans were performed on 8 healthy volunteers using 1 and 6 gradient directions. Cluster analysis was carried out to separate motion-contaminated parenchyma from liver parenchyma and vessels. Nonlinear motion analysis was also performed to look for a possible link between IVIM metrics and nonlinear liver motion. RESULTS: On the basis of the resulted clusters, motion-contaminated parenchyma is often noted in the left liver lobe, where the prominent pseudohepatic artifact has previously been identified. A significant reduction in outliers was obtained with the acquisition of 6 noncoplanar gradient directions and when using forced shallow free-breathing. CONCLUSION: The pseudohepatic anisotropy artifact can be minimized when using multiple diffusion-encoding gradient directions and forced free-breathing during IVIM acquisition.


Assuntos
Artefatos , Processamento de Imagem Assistida por Computador/métodos , Fígado/anatomia & histologia , Imageamento por Ressonância Magnética/métodos , Adulto , Anisotropia , Suspensão da Respiração , Análise por Conglomerados , Feminino , Humanos , Masculino , Movimento (Física) , Valores de Referência , Reprodutibilidade dos Testes , Respiração
7.
J Comput Assist Tomogr ; 41(4): 578-585, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-27997442

RESUMO

OBJECTIVE: The aim of this study was to evaluate the effect of signal to noise ratio (SNR) and number of gradient directions (NGD) on intra- and intersession repeatability of liver diffusion tensor imaging (DTI) metrics. METHODS: At each of 3 liver DTI scan sessions, liver diffusion was assessed in 5 healthy volunteers using a 6-direction DTI scan performed 9 separate times (ie, number of signal averages [NSA]). In addition, 4 combinations of NSA and NGD were acquired (NSA/NGD = 1/30, 3/10, 3/12, and 5/6) to determine the combined effect to DTI metrics, which was based on intersubject variability and intrasession (Vintra) and intersession (Vinter) repeatability. RESULTS: Intersubject variability was less than 20%, whereas Vintra and Vinter repeatability were less than 5% and less than 10%, respectfully. Vinter was not affected by the NGD used. Decreases in Vinter(FA), Vinter(λ1), Vinter(RD), and Vinter(MD) were observed with increasing NSA, and hence SNR. CONCLUSION: Increased SNR may improve intrasession and intersession repeatability of liver DTI metrics. Scan repeatability was not influenced by NGD.


Assuntos
Imagem de Tensor de Difusão/métodos , Processamento de Imagem Assistida por Computador/métodos , Fígado/anatomia & histologia , Adulto , Feminino , Humanos , Masculino , Variações Dependentes do Observador , Valores de Referência , Reprodutibilidade dos Testes , Razão Sinal-Ruído
8.
AJR Am J Roentgenol ; 205(1): W67-72, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26102420

RESUMO

OBJECTIVE: The purpose of this study was to evaluate differences in the diagnostic accuracy of absolute and relative territorial myocardial blood flow (MBF) derived from stress dynamic CT myocardial perfusion imaging (MPI) for the detection of significant coronary artery stenosis. MATERIALS AND METHODS: Dynamic CT MPI and coronary CT angiography (CTA) datasets from a multicenter registry of 137 patients (mean age, 60.9 ± 8.4 years; 88 men) with suspected or known coronary artery disease were retrospectively analyzed. For each coronary territory, absolute MBF and the MBF relative to remote myocardium (MBF ratio) were calculated. Coronary CTA datasets were visually assessed for significant stenosis (≥ 50% luminal narrowing) in consensus by two observers. RESULTS: Significant stenosis was detected in 137 of 411 (33.3%) vessels. Mean absolute MBF and MBF ratio were statistically significantly lower in territories supplied by arteries with stenosis (80.7 ± 33.7 vs 140.0 ± 38.4 mL/100 mL/min and 0.52 vs 0.89, respectively; both p < 0.0001). ROC analysis showed better discrimination by MBF ratio than by absolute MBF (AUC, 0.925 vs 0.882; p = 0.0022) and increased sensitivity (90.7% vs 82.4%; p < 0.04) and specificity (93.1% vs 80.5%; p < 0.03) for MBF ratio and absolute MBF cutoff values of 0.71 or less and 103 mL/100 mL/min or less, respectively. CONCLUSION: In stress dynamic CT MPI, relative MBF provides superior diagnostic accuracy compared with absolute territorial MBF values for coronary CTA-detected significant coronary artery stenosis.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Circulação Coronária , Imagem Multimodal , Imagem de Perfusão do Miocárdio/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Técnicas de Imagem de Sincronização Cardíaca , Angiografia Coronária , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade
9.
J Am Soc Nephrol ; 25(1): 175-86, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24052631

RESUMO

Vitamin D seems to protect against cardiovascular disease, but the reported effects of vitamin D on patient outcomes in CKD are controversial. We conducted a prospective, double blind, randomized, placebo-controlled trial to determine whether oral activated vitamin D reduces left ventricular (LV) mass in patients with stages 3-5 CKD with LV hypertrophy. Subjects with echocardiographic criteria of LV hypertrophy were randomly assigned to receive either oral paricalcitol (1 µg) one time daily (n=30) or matching placebo (n=30) for 52 weeks. The primary end point was change in LV mass index over 52 weeks, which was measured by cardiac magnetic resonance imaging. Secondary end points included changes in LV volume, echocardiographic measures of systolic and diastolic function, biochemical parameters of mineral bone disease, and measures of renal function. Change in LV mass index did not differ significantly between groups (median [interquartile range], -2.59 [-6.13 to 0.32] g/m(2) with paricalcitol versus -4.85 [-9.89 to 1.10] g/m(2) with placebo). Changes in LV volume, ejection fraction, tissue Doppler-derived measures of early diastolic and systolic mitral annular velocities, and ratio of early mitral inflow velocity to early diastolic mitral annular velocity did not differ between the groups. However, paricalcitol treatment significantly reduced intact parathyroid hormone (P<0.001) and alkaline phosphatase (P=0.001) levels as well as the number of cardiovascular-related hospitalizations compared with placebo. In conclusion, 52 weeks of treatment with oral paricalcitol (1 µg one time daily) significantly improved secondary hyperparathyroidism but did not alter measures of LV structure and function in patients with severe CKD.


Assuntos
Ergocalciferóis/uso terapêutico , Hipertrofia Ventricular Esquerda/tratamento farmacológico , Hipertrofia Ventricular Esquerda/etiologia , Insuficiência Renal Crônica/complicações , Insuficiência Renal Crônica/tratamento farmacológico , Disfunção Ventricular Esquerda/tratamento farmacológico , Disfunção Ventricular Esquerda/etiologia , Idoso , Fosfatase Alcalina/sangue , Pressão Sanguínea/efeitos dos fármacos , Método Duplo-Cego , Ecocardiografia , Ergocalciferóis/efeitos adversos , Feminino , Humanos , Hipercalcemia/induzido quimicamente , Hipertrofia Ventricular Esquerda/patologia , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Hormônio Paratireóideo/sangue , Estudos Prospectivos , Insuficiência Renal Crônica/patologia , Disfunção Ventricular Esquerda/fisiopatologia
10.
J Digit Imaging ; 28(3): 302-8, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25561071

RESUMO

With the implementation of the PACS in the hospital, there is an increasing demand from the clinicians for immediate access and display of radiological images. Recently, our hospital has installed the first wireless local area network (WLAN)-based direct digital radiography (DDR) portable radiography system. The DDR portable radiography system allows wireless retrieval of modality worklist and wireless transmission of portable X-ray image on the console to the Picture Archiving and Communication System (PACS), via WLAN connection of wireless fidelity (Wi-Fi). The aim of this study was to analyze the workflow and performance between the WLAN-based DDR portable radiography system and the old practice using conventional portable X-ray machine with computed radiography (CR) system. A total of 190 portable chest X-ray examinations were evaluated and timed, using the conventional portable X-ray machine with CR from March to April of 2012 and using the new DDR portable radiography system on December of 2012 (n = 97 for old system and n = 93 for DDR portable system). The time interval of image becoming available to the PACS using the WLAN-based DDR portable radiography system was significantly shorter than that of the old practice using the conventional portable X-ray machine with CR (6.8 ± 2.6 min for DDR portable system; 23 ± 10.2 min for old system; p < 0.0001), with the efficiency improved by 70 %. The implementation of the WLAN-based DDR portable radiography system can enhance the workflow of portable radiography by reduction of procedural steps.


Assuntos
Redes Locais , Sistemas de Informação em Radiologia , Fluxo de Trabalho , Humanos
11.
Eur Radiol ; 24(1): 191-9, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24013818

RESUMO

OBJECTIVES: To evaluate the performance of three-dimensional semi-automated evaluation software for the assessment of myocardial blood flow (MBF) and blood volume (MBV) at dynamic myocardial perfusion computed tomography (CT). METHODS: Volume-based software relying on marginal space learning and probabilistic boosting tree-based contour fitting was applied to CT myocardial perfusion imaging data of 37 subjects. In addition, all image data were analysed manually and both approaches were compared with SPECT findings. Study endpoints included time of analysis and conventional measures of diagnostic accuracy. RESULTS: Of 592 analysable segments, 42 showed perfusion defects on SPECT. Average analysis times for the manual and software-based approaches were 49.1 ± 11.2 and 16.5 ± 3.7 min respectively (P < 0.01). There was strong agreement between the two measures of interest (MBF, ICC = 0.91, and MBV, ICC = 0.88, both P < 0.01) and no significant difference in MBF/MBV with respect to diagnostic accuracy between the two approaches for both MBF and MBV for manual versus software-based approach; respectively; all comparisons P > 0.05. CONCLUSIONS: Three-dimensional semi-automated evaluation of dynamic myocardial perfusion CT data provides similar measures and diagnostic accuracy to manual evaluation, albeit with substantially reduced analysis times. This capability may aid the integration of this test into clinical workflows. KEY POINTS: • Myocardial perfusion CT is attractive for comprehensive coronary heart disease assessment. • Traditional image analysis methods are cumbersome and time-consuming. • Automated 3D perfusion software shortens analysis times. • Automated 3D perfusion software increases standardisation of myocardial perfusion CT. • Automated, standardised analysis fosters myocardial perfusion CT integration into clinical practice.


Assuntos
Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico , Imageamento Tridimensional/métodos , Imagem de Perfusão do Miocárdio , Software , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tomografia Computadorizada por Raios X/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos
12.
AJR Am J Roentgenol ; 203(2): W174-80, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24848691

RESUMO

OBJECTIVE: The purpose of this study was to determine the feasibility of global quantitative measurements of left ventricular myocardial perfusion derived from stress dynamic CT myocardial perfusion imaging. MATERIALS AND METHODS: The coronary CT angiographic and CT myocardial perfusion imaging datasets of 146 patients were visually evaluated for the presence of coronary artery stenosis and perfusion defects. For the quantitative analysis, volumes of interest were defined over the entire left ventricular myocardium to obtain global myocardial blood flow (MBF), myocardial blood volume (MBV), and volume transfer constant (K(trans)). RESULTS: In patients without anatomically significant coronary stenosis or perfusion defects, the mean value of global MBF was 137.9 ± 28.8 mL/100 mL/min; MBV, 19.5 ± 2.3 mL/100 mL; and K(trans), 85.8 ± 15.2 mL/100 mL/min. In patients with perfusion defects in one, two, or three vessels, the mean global MBF values were 132.6 ± 29.2, 117.4 ± 4.9, and 92.5 ± 11.2 mL/100 mL/min; MBV, 17.9 ± 3.2, 16.1 ± 3.1, and 12.8 ± 1.7 mL/100 mL; and K(trans), 80.4 ± 12.9, 76.6 ± 13.8, and 72.6 ± 15.5 mL/100 mL/min. In patients with significant (> 50%) stenosis in one, two, or three vessels at coronary CT angiography, the mean global MBF values were 129.2 ± 28.3, 120.5 ± 24.2, and 119.4 ± 33.5 mL/100 mL/min; MBV, 17.8 ± 3.3, 17.2 ± 3.2, and 14.7 ± 4.1 mL/100 mL; and K(trans), 80.3 ± 12.9, 76.0 ± 14.7, and 77.6 ± 13.2 mL/100 mL/min. CONCLUSION: Global quantitative assessment of left ventricular perfusion with stress dynamic CT myocardial perfusion imaging is feasible, and the findings correlate with the visual assessment of perfusion and the presence of coronary artery stenosis at coronary CT angiography. The potential clinical utility of this technique as a diagnostic tool for differentiating normal from globally reduced myocardial perfusion or as a prognostic marker merits further investigation.


Assuntos
Estenose Coronária/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Técnicas de Imagem de Sincronização Cardíaca , Meios de Contraste , Angiografia Coronária , Circulação Coronária , Estudos de Viabilidade , Feminino , Humanos , Imageamento Tridimensional , Iohexol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Sistema de Registros , Estudos Retrospectivos
13.
J Comput Assist Tomogr ; 38(3): 352-9, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24681854

RESUMO

OBJECTIVE: To evaluate the effect of respiratory and cardiac motion on diffusion tensor imaging (DTI) metrics in healthy human liver. METHODS: Fifteen healthy subjects, participating in either part of this study, were scanned using a 1.5-T magnetic resonance imaging (MRI) device. Coronal liver DTI (6 diffusion-encoding directions; b, 300 mm/s) during breath holding was compared to free breathing. Cardiac motion effects were evaluated by comparing breath-held DTI scans acquired during both diastole and systole. RESULTS: Free breathing resulted in a significantly increased mean diffusivity (P < 0.05), λ1 (P < 0.01), λ2 (P < 0.05), and λ3 (P < 0.01) compared to breath holding. During systole significant increases in fractional anisotropy (P < 0.05), mean diffusivity (P < 0.05), and λ1 (P < 0.05), compared to systole, were found in the left lobe. The right lobe, which is less affected by cardiac motion, showed no significant change in DTI metrics over the cardiac cycle. CONCLUSIONS: Respiratory and cardiac motion tends to increase liver DTI metrics.


Assuntos
Artefatos , Imagem de Tensor de Difusão/métodos , Coração/anatomia & histologia , Coração/fisiologia , Fígado/anatomia & histologia , Fígado/fisiologia , Mecânica Respiratória/fisiologia , Adulto , Suspensão da Respiração , Feminino , Humanos , Masculino , Movimento (Física) , Movimento , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
14.
Hong Kong Med J ; 19(4): 294-9, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23832947

RESUMO

OBJECTIVES: To review the impact of preoperative breast magnetic resonance imaging on the management of planned surgery, and the appropriateness of any resulting alterations. DESIGN: Retrospective review. SETTING: A private hospital in Hong Kong. PATIENTS; For the 147 consecutive biopsy-proven breast cancer patients who underwent preoperative magnetic resonance imaging to determine tumour extent undergoing operation by a single surgeon between 1 January 2006 and 31 December 2009, the impact of magnetic resonance imaging findings was reviewed in terms of management alterations and their appropriateness. RESULTS: The most common indication for breast magnetic resonance imaging was the presence of multiple indeterminate shadows on ultrasound scans (53%), followed by ill-defined border of the main tumour on ultrasound scans (19%). In 66% (97 out of 147) of the patients, the extent of the operation was upgraded. Upgrading entailed: lumpectomy to wider lumpectomy (23 out of 97), lumpectomy to mastectomy (47 out of 97), lumpectomy to bilateral lumpectomy (15 out of 97), and other (12 out of 97). Mostly, these management changes were because magnetic resonance imaging showed more extensive disease (n=29), additional cancer foci (n=39), or contralateral disease (n=24). In five instances, upgrading was due to patient preference. In 34% (50 out of 147) of the patients, there was no change in the planned operation. Regarding 97 of the patients having altered management, in 12 the changes were considered inappropriately extensive (due to false-positive magnetic resonance imaging findings). In terms of magnetic resonance imaging detection of more extensive, multifocal, multicentric, or contralateral disease, the false-positive rate was 13% and false-negative rate 7%. Corresponding rates for sensitivity and specificity were 95% and 81%, using the final pathology as the gold standard. CONCLUSIONS: Preoperative magnetic resonance imaging had a clinically significant and mostly correct impact on management plans. Magnetic resonance imaging should be included as part of the preoperative investigation in patients planned for breast-conserving surgery, in whom there are doubts about the extent of the tumours based on conventional assessment.


Assuntos
Neoplasias da Mama/patologia , Imageamento por Ressonância Magnética/métodos , Mastectomia Segmentar/métodos , Mastectomia/métodos , Adulto , Idoso , Biópsia por Agulha Fina , Neoplasias da Mama/cirurgia , Estudos de Coortes , Reações Falso-Negativas , Reações Falso-Positivas , Feminino , Hong Kong , Hospitais Privados , Humanos , Pessoa de Meia-Idade , Preferência do Paciente , Cuidados Pré-Operatórios/métodos , Estudos Retrospectivos , Sensibilidade e Especificidade
15.
Diagnostics (Basel) ; 13(23)2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-38066821

RESUMO

Radiomics has the potential to aid prostate cancer (PC) diagnoses and prediction by analyzing and modeling quantitative features extracted from clinical imaging. However, its reliability has been a concern, possibly due to its high-dimensional nature. This study aims to quantitatively investigate the impact of randomly generated irrelevant features on MRI radiomics feature selection, modeling, and performance by progressively adding randomly generated features. Two multiparametric-MRI radiomics PC datasets were used (dataset 1 (n = 260), dataset 2 (n = 100)). The endpoint was to differentiate pathology-confirmed clinically significant (Gleason score (GS) ≥ 7) from insignificant (GS < 7) PC. Random features were generated at 12 levels with a 10% increment from 0% to 100% and an additional 5%. Three feature selection algorithms and two classifiers were used to build the models. The area under the curve and accuracy were used to evaluate the model's performance. Feature importance was calculated to assess features' contributions to the models. The metrics of each model were compared using an ANOVA test with a Bonferroni correction. A slight tendency to select more random features with the increasing number of random features introduced to the datasets was observed. However, the performance of the radiomics-built models was not significantly affected, which was partially due to the higher contribution of radiomics features toward the models compared to the random features. These reliability effects also vary among datasets. In conclusion, while the inclusion of additional random features may still slightly impact the performance of the feature selection, it may not have a substantial impact on the MRI radiomics model performance.

16.
Quant Imaging Med Surg ; 12(2): 1585-1607, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35111651

RESUMO

Magnetic resonance guided radiotherapy (MRgRT), enabled by the clinical introduction of the integrated MRI and linear accelerator (MR-LINAC), is a novel technique for prostate cancer (PCa) treatment, promising to further improve clinical outcome and reduce toxicity. The role of prostate MRI has been greatly expanded from the traditional PCa diagnosis to also PCa screening, treatment and surveillance. Diagnostic prostate MRI has been relatively familiar in the community, particularly with the development of Prostate Imaging - Reporting and Data System (PI-RADS). But, on the other hand, the use of MRI in the emerging clinical practice of PCa MRgRT, which is substantially different from that in PCa diagnosis, has been so far sparsely presented in the medical literature. This review attempts to give a comprehensive overview of MRI acquisition techniques currently used in the clinical workflows of PCa MRgRT, from treatment planning to online treatment guidance, in order to promote MRI practice and research for PCa MRgRT. In particular, the major differences in the MRI acquisition of PCa MRgRT from that of diagnostic prostate MRI are demonstrated and explained. Limitations in the current MRI acquisition for PCa MRgRT are analyzed. The future developments of MRI in the PCa MRgRT are also discussed.

17.
Hepatol Int ; 16(2): 371-380, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35347596

RESUMO

BACKGROUND: Magnetic resonance (MR) elastography and proton density fat fraction (PDFF) are emerging techniques for non-invasive assessment of liver stiffness and steatosis, respectively. We investigated the role of MR metrics in pre-treatment prognostication of hepatocellular carcinoma (HCC). METHODS: Patients with newly diagnosed HCC were prospectively recruited. Pre-treatment MR elastography and PDFF were performed on tumor and non-tumor regions. HCC treatment was categorized as potentially curative (resection/ablation) or non-curative (locoregional/systemic therapy). HCC recurrence, liver-related complications (ascites/ variceal bleeding/ hepatic encephalopathy) and mortality were monitored. RESULTS: Of the 158 recruited patients (mean age 62.9 years, 84.2% male, 82.9% viral hepatitis), 58.2% (n = 92) and 41.8% (n = 66) received potentially curative and non-curative therapy, respectively. Pre-treatment non-tumor liver stiffness independently predicted liver-related complications, regardless of treatment type (HR 1.384, 95% CI 1.067-1.796, p = 0.014). In the potentially curative therapy group, non-tumor stiffness and non-tumor PDFF were independently associated with HCC recurrence (HR 1.308, 95% CI 1.022-1.673 & HR 1.080, 95% CI 1.009-1.156 respectively, both p < 0.05); and non-tumor PDFF predicted mortality (HR 1.160, 95% CI 1.038-1.296, p = 0.009). In the non-curative group, tumor stiffness independently predicted liver-related complications (HR 1.299, 95% CI 1.023-1.651, p = 0.032), and a combination of tumor stiffness ≥ 5.7 kPa plus non-tumor stiffness ≥ 3.7 kPa was associated with a two-fold risk of liver-related complications (86.7% vs 40.0%, p < 0.001). CONCLUSION: Pre-treatment MR elastography and PDFF over tumor and non-tumor regions demonstrated prognosticating roles in HCC. Simultaneous measurements of both metrics during conventional MR liver should be considered in the diagnostic workup of HCC.


Assuntos
Carcinoma Hepatocelular , Técnicas de Imagem por Elasticidade , Varizes Esofágicas e Gástricas , Neoplasias Hepáticas , Carcinoma Hepatocelular/patologia , Técnicas de Imagem por Elasticidade/métodos , Varizes Esofágicas e Gástricas/complicações , Feminino , Hemorragia Gastrointestinal/complicações , Humanos , Fígado/diagnóstico por imagem , Fígado/patologia , Neoplasias Hepáticas/patologia , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Prótons
18.
J Cancer Res Clin Oncol ; 148(7): 1749-1759, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34363123

RESUMO

PURPOSE: Performance of 3D-T1W-TSE has been proven superior to 3D-MP-GRE at 3 T on brain metastases (BM) contrast-enhanced (CE) MRI. However, its performance at 1.5 T is largely unknown and sparsely reported. This study aims to assess image quality, lesion detectability and conspicuity of 1.5 T 3D-T1W-TSE on planning MRI of frameless BM radiotherapy. METHODS: 94 BM patients to be treated by frameless brain radiotherapy were scanned using 3D-T1W-TSE with immobilization on multi-vendor 1.5 T MRI-simulators. BMs were jointly diagnosed by 4 reviewers. Enhanced lesion conspicuity was quantitatively assessed by calculating contrast ratio (CR) and contrast-to-noise ratio (CNR). Signal-to-noise ratio (SNR) reduction of white matter due to the use of flexible coil was assessed. Lesion detectability and conspicuity were compared between 1.5 T planning MRI and 3 T diagnostic MRI by an oncologist and a radiologist in 10 patients. RESULTS: 497 BMs were jointly diagnosed. The CR and CNR were 75.2 ± 39.9% and 14.2 ± 8.1, respectively. SNR reduced considerably from 31.7 ± 8.3 to 21.9 ± 5.4 with the longer distance to coils. 3 T diagnostic MRI and 1.5 T planning MRI yielded exactly the same detection of 84 BMs. Qualitatively, lesion conspicuity at 1.5 T was not inferior to that at 3 T. Quantitatively, lower brain SNR and lesion CNR were found at 1.5 T, while lesion CR at 1.5 T was highly comparable to that at 3 T. CONCLUSION: 1.5 T 3D-T1W-TSE planning MRI of frameless BM radiotherapy was comprehensively assessed. Highly comparable BM detectability and conspicuity were achieved by 1.5 T planning MRI compared to 3 T diagnostic MRI. 1.5 T 3D-T1W-TSE should be valuable for frameless brain radiotherapy planning.


Assuntos
Neoplasias Encefálicas , Radioterapia (Especialidade) , Encéfalo , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/radioterapia , Meios de Contraste , Humanos , Imageamento por Ressonância Magnética/métodos
19.
Asia Pac J Clin Oncol ; 18(5): e369-e377, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35073460

RESUMO

PURPOSE: To assess the image quality and delineation value of compressed sensing (CS)-accelerated 3D T2W turbo-spin-echo (TSE) sequence for radiotherapy treatment planning (RTP) of prostate cancer. METHODS: An optimized CS-accelerated 3D-T2W-TSE was determined by volunteer imaging and applied for clinical RTP-MRI. This optimized CS-accelerated planning MRI and the standardized adaptive MRI acquired at 1.5T were retrospectively analyzed in 26 prostate cancer patients who were to receive MR-guided radiotherapy. Signal-to-noise ratio (SNR) and relative contrast ratio (CR) were quantitatively assessed. Image quality and artifacts were qualitatively assessed using a five-point scale rating. Delineation value in the prostate and organs-at-risk (OARs) was also rated and compared. Wilcoxon signed-rank test was used for SNR, relative CR, and rating comparisons. The interobserver rating agreement was evaluated by percent agreement. RESULTS: Significantly better SNR and relative CR in the prostate, rectum, bowel, penis, and penile bulb, while significantly worse in the cauda equina, were observed on the planning MRI. Significantly better ratings of image quality and artifacts were given to the planning MRI, with much less Gibbs ringing and reconstruction artifacts. Significantly better delineation value rating was achieved on the planning MRI in the prostate, seminal vesicle, rectum, penis, penile bulb, and testes, while significantly worse in the cauda equina. A strong to almost perfect interobserver rating agreement was obtained. CONCLUSION: This study suggested that CS acceleration is applicable and valuable in prostate RTP-MRI. CS-accelerated 3D-T2W-TSE images should benefit the delineation of prostate and many OARs.


Assuntos
Imageamento por Ressonância Magnética , Neoplasias da Próstata , Aceleração , Artefatos , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Estudos Retrospectivos
20.
Psychopharmacology (Berl) ; 239(7): 2133-2141, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35211769

RESUMO

RATIONALE: How striatal dopamine synthesis capacity (DSC) contributes to the pathogenesis of negative symptoms in first-episode schizophrenia (SZ) and delusional disorder (DD) has seldom been explored. As negative symptoms during active psychotic episodes can be complicated by secondary influences, such as positive symptoms, longitudinal investigations may help to clarify the relationship between striatal DSC and negative symptoms and differentiate between primary and secondary negative symptoms. OBJECTIVE: A longitudinal study was conducted to examine whether baseline striatal DSC would be related to negative symptoms at 3 months in first-episode SZ and DD patients. METHODS: Twenty-three first-episode age- and gender-matched patients (11 DD and 12 SZ) were consecutively recruited through an early intervention service for psychosis in Hong Kong. Among them, 19 (82.6%) patients (9 DD and 10 SZ) were followed up at 3 months. All patients received an 18F-DOPA PET/MR scan at baseline. RESULTS: Baseline striatal DSC (Kocc;30-60) was inversely associated with negative symptoms at 3 months in first-episode SZ patients (rs = - 0.80, p = 0.010). This association remained in SZ patients even when controlling for baseline negative, positive, and depressive symptoms, as well as cumulative antipsychotic dosage (ß = - 0.69, p = 0.012). Such associations were not observed in first-episode DD patients. Meanwhile, the severity of negative symptoms at 3 months was associated with more positive symptoms in DD patients (rs = 0.74, p = 0.010) and not in SZ patients. CONCLUSIONS: These findings highlight the role of striatal DSC in negative symptoms upon resolution of active psychotic episodes among first-episode SZ patients. Baseline striatal dopamine activity may inform future symptom expression with important treatment implications.


Assuntos
Dopamina , Transtornos Psicóticos , Corpo Estriado/diagnóstico por imagem , Corpo Estriado/metabolismo , Dopamina/metabolismo , Humanos , Estudos Longitudinais , Transtornos Psicóticos/metabolismo , Esquizofrenia Paranoide/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA