Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 98
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Gastrointest Endosc ; 99(2): 237-244.e1, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37536633

RESUMO

BACKGROUND AND AIMS: Mucosal closure adds time but reduces adverse events associated with endoscopic submucosal dissection (ESD). We aimed to assess the closure time (CT), technical success, and cost-effectiveness between a novel through-the-scope helix tack suture system (TTSS) and the over-the-scope suturing system (OTSS). METHODS: In this single-center, prospective, randomized trial, all patients undergoing ESD with anticipated closure were randomized 1:1 to TTSS (study group) or OTSS (control group). Primary outcomes were CT and overall CT (OCT; CT + setup time). Secondary outcomes were rates of technical success, adverse events, and cost-effectiveness. RESULTS: Forty patients were randomized to OTSS (n = 20) or TTSS (n = 20). OTSS and TTSS groups were similar with respect to age, gender, proportion of colorectal polyps, proximal colon polyps, and mean size of the resected specimen (40.9 mm vs 40.4 mm). The mean CT was 18.4 minutes for OTSS and 23.3 minutes for TTSS (P = .36). The mean OCT was 32 minutes for OTSS and 39.5 minutes for TTSS (P = .36). Closure with a primary device was successful in 17 cases (85%) with OTSS and 18 cases (90%) with TTSS (P = .63). No closure-related intraprocedural adverse events or delayed perforations were noted. Mean cost of closure was significantly lower in the TTSS group for lesions <35 mm (P = .008). CONCLUSIONS: TTSS was not found to be superior to OTSS with respect to CT and technical and clinical success for closure of gastric and colorectal ESD defects. TTSS is more cost-effective for closure of lesions <35 mm. (Clinical trial registration number: NCT04925271.).


Assuntos
Neoplasias Colorretais , Ressecção Endoscópica de Mucosa , Humanos , Ressecção Endoscópica de Mucosa/métodos , Estudos Prospectivos , Estômago , Neoplasias Colorretais/cirurgia , Neoplasias Colorretais/etiologia , Suturas , Resultado do Tratamento , Estudos Retrospectivos
2.
Gastrointest Endosc ; 99(4): 606-613, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37951278

RESUMO

BACKGROUND AND AIMS: Lumen-apposing metal stents (LAMSs) have revolutionized the treatment of various gastroenterologic conditions that previously required surgery. The use of LAMSs for the management of small-bowel obstruction (SBO) involves EUS-guided coloenterostomy (EUS-CE) between the colon and a dilated loop of the small intestine proximal to the point of obstruction. This procedure is potentially beneficial for patients with malignant SBO who are poor surgical candidates. METHODS: A retrospective cohort study was conducted at 2 tertiary care hospitals. Patients who underwent EUS-CE for SBO were identified, and data regarding patient demographics, indication for the procedure, location of the obstruction, procedural details, and adverse events were collected. The primary outcome was technical success of the procedure. Secondary outcomes were clinical success, resolution of symptoms, ability to tolerate enteral nutrition, and adverse events. RESULTS: Twenty-six patients who underwent the EUS-CE procedure were included. Technical success was achieved in all 26 patients, clinical success (resolution of obstructive symptoms) was achieved in 92.3% of patients (24/26), and the ability to resume enteral nutrition in 84.6% (22/26). Adverse events occurred in 4 patients (15.4%) and included bleeding (1/26), diarrhea (2/26), and postprocedure sepsis (1/26). Patients were followed for a mean of 54.8 days (range, 2-190). CONCLUSIONS: This study highlights that EUS-CE with LAMSs can be performed with high technical and clinical success for the management of SBO, particularly in patients with malignant obstructions who are not suitable candidates for surgical interventions. Further research with larger sample sizes will be essential to substantiate its efficacy and safety.


Assuntos
Endossonografia , Stents , Humanos , Estudos Retrospectivos , Intestino Delgado , Colo , Drenagem/métodos , Ultrassonografia de Intervenção , Resultado do Tratamento
3.
Gastrointest Endosc ; 2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-38431104

RESUMO

BACKGROUND AND AIMS: Direct endoscopic necrosectomy (DEN) is a recommended strategy for treatment of walled-off-necrosis (WON). DEN uses a variety of devices including the EndoRotor (Interscope, Inc.) debridement catheter. Recently, a 5.1 mm EndoRotor with increased chamber size and rate of tissue removal was introduced. The aim of this study was to assess the efficacy and safety of this device. METHODS: A multi-center cohort study was conducted at eight institutions including patients who underwent DEN with the 5.1 mm EndoRotor. The primary outcome was the number of DEN sessions needed for WON resolution. Secondary outcomes included the average percent reduction in solid WON debris and decrease in WON area per session, total time spent performing EndoRotor therapy for WON resolution, and adverse events. RESULTS: 64 procedures in 41 patients were included. For patients in which the 5.1 mm EndoRotor catheter was the sole therapeutic modality, an average of 1.6 DEN sessions resulted in WON resolution with an average cumulative time of 85.5 minutes. Of the 21 procedures with data regarding percent of solid debris, the average reduction was 85% +/- 23% per session. Of the 19 procedures with data regarding WON area, the mean area significantly decreased from 97.6 +/- 72.0 cm2 to 27.1 +/- 35.5 cm2 (p<0.001) per session. Adverse events included two intra-procedural LAMS dislodgements managed endoscopically and three perforations none of which were related to EndoRotor. Bleeding was reported in seven cases, none required embolic or surgical therapy and two required blood transfusions. CONCLUSIONS: This is the first multi-center retrospective study to investigate the efficacy and safety of the 5.1 mm EndoRotor catheter for WON. Results from this study showed an average of 1.6 DEN sessions were needed to achieve WON resolution with an 85% single session reduction in solid debris and a 70% single session decrease in WON area with minimal adverse events.

4.
Gastrointest Endosc ; 98(1): 7-18.e4, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36907527

RESUMO

BACKGROUND AND AIMS: The practices for resection of diminutive colon polyps vary among endoscopists, and U.S. Multi-Society Task force guidelines recommend use of cold snare polypectomy (CSP) for this purpose. In this meta-analysis, we compared CSP and cold forceps polypectomy (CFP) for resection of diminutive polyps. METHODS: Several databases were reviewed to identify randomized controlled trials that compared CSP and CFP for resection of diminutive polyps. The study outcomes of interest were complete resection of all diminutive polyps, complete resection of polyps ≤3 mm in size, failure of tissue retrieval, and polypectomy time. For categorical variables, pooled odds ratios (ORs) with 95% confidence intervals (CIs) were calculated; for continuous variables, mean differences (MDs) with 95% CIs were calculated. Data were analyzed by using a random-effects model, and heterogeneity was assessed by using the I2 statistic. RESULTS: We included 9 studies with 1037 patients. Rate of complete resection of all diminutive polyps was significantly higher in the CSP group (OR, 1.68; 95% CI, 1.09-2.58). Subgroup analysis, including jumbo or large-capacity forceps, found no significant difference in complete resection between groups (OR, 1.43; 95% CI, .80-2.56). We found no significant between-groups in the rates of complete resection of polyps ≤3 mm in size (OR, .83; 95% CI, .30-2.31). Rate of failure of tissue retrieval was significantly higher in the CSP group (OR, 10.13; 95% CI, 2.29-44.74). No significant between-group difference was noted in polypectomy time. CONCLUSIONS: CFP using large-capacity or jumbo biopsy forceps is noninferior to CSP for complete resection of diminutive polyps.


Assuntos
Pólipos do Colo , Neoplasias Colorretais , Humanos , Pólipos do Colo/cirurgia , Pólipos do Colo/patologia , Colonoscopia , Neoplasias Colorretais/patologia , Ensaios Clínicos Controlados Aleatórios como Assunto , Instrumentos Cirúrgicos
5.
J Clin Gastroenterol ; 57(2): 218-226, 2023 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-33899781

RESUMO

BACKGROUND AND AIMS: Endoscopic decompression is considered a first-line treatment for symptomatic pancreatic fluid collections (PFCs). A lumen-apposing metal stent (LAMS) with an electrocautery-enhanced delivery system [electrocautery-enhanced lumen-apposing metal stent (ELAMS)] may facilitate this procedure. This study evaluated the safety and efficacy of ELAMS in the management of symptomatic PFCs. PATIENTS AND METHODS: A multicenter, nonblinded, prospective, Food and Drug Administration (FDA)-approved, investigational device exemption clinical trial was conducted. Enrollment criteria included symptomatic PFCs ≥6 cm with ≥70% fluid fraction. Subjects were followed prospectively for safety, efficacy, and resolution of the collections. Primary endpoint success was defined as ≥50% reduction in PFC size. Clinical outcomes were compared with our previously published series of LAMS without the cautery-enhanced delivery system. RESULTS: The target enrollment of 30 patients was achieved in 7 US tertiary care centers. All patients underwent successful placement of the ELAMS. The mean procedure duration, stent placement time, and fluoroscopy exposures were 28.1±12.5, 5.8±2.6, and 1.8±1.6 minutes, respectively. Eight patients had no fluoroscopy. The primary endpoint was achieved in 83.3% of patients. Two adverse events were attributed to the ELAMS: 1 bleeding upon stent removal and 1 stent migration. Relative to the comparator noncautery LAMS multicenter trial (N=33, 8 tertiary centers), there was a significantly shorter procedure duration [36 min ( P <0.001)] with similar technical and clinical outcomes in the ELAMS cohort. CONCLUSION: LAMS placed using an electrocautery delivery system significantly reduce procedure duration and were safe and effective in the management of symptomatic PFCs.


Assuntos
Descompressão Cirúrgica , Pancreatopatias , Humanos , Drenagem/métodos , Eletrocoagulação , Endossonografia , Vértebras Lombares/cirurgia , Metais/efeitos adversos , Pancreatopatias/cirurgia , Estudos Prospectivos , Stents/efeitos adversos
6.
J Clin Gastroenterol ; 2023 Aug 29.
Artigo em Inglês | MEDLINE | ID: mdl-37646532

RESUMO

BACKGROUND: Endoscopic ultrasound (EUS)-guided gastroenterostomy (EUS-GE) is a minimally invasive therapy for patients with gastric outlet obstruction without the risks of surgical bypass and the limited long-term efficacy of enteral self-expanding metal stent placement. However, due to its novelty, there is a lack of significant data comparing long-term outcomes of patients with EUS-GE, based on the underlying disease. In this study, we compare outcomes of EUS-GE on benign versus malignant indications. METHODS: Consecutive patients from 12 international, tertiary care centers who underwent EUS-GE over 3 years were extracted in a retrospective registry. Demographic characteristics, procedure-related information and follow-up data was collected. Primary outcome was the rate of adverse events associated with EUS-GE and the comparison of the rate of adverse events in benign versus malignant diseases. Secondary outcomes included technical and clinical success as well as hospitalization admission. RESULTS: A total of 103 patients were included: 72 malignant and 31 benign. The characteristics of the patients undergoing EUS-GE is shown in Table 1. The mean age of the cohort was 68 years and 58 years for malignant and benign etiology. Gender distribution was 57% and 39% being females in malignant and benign etiology group, respectively. Clinical success, technical success, average procedure time, and hospital length of stay were similar in both groups. Patients with benign underlying etiology had significantly higher number of surgically altered midgut anatomy (P=0.0379). CONCLUSION: EUS-GE is equally efficient regardless of the underlying etiology (malignant vs. benign), and the adverse events both groups were comparable.

7.
J Clin Gastroenterol ; 57(8): 798-803, 2023 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-35997700

RESUMO

INTRODUCTION: Single-use disposable duodenoscopes (SDD) have been developed to mitigate infectious risks related to reusable duodenoscopes. The aim of this study is to compare the safety and efficacy of the two available SDDs in the United States. METHODS: We conducted a comparative study of 2 SDD in consecutive ERCP procedures performed by expert endoscopists from 9 academic centers. Performance ratings, procedure details, and adverse events were collected. RESULTS: A total of 201 patients were included: 129 patients underwent ERCP with Exalt (mean age 63, Males- 66 (51%), 72 with aScope Duodeno (mean age 65, males=30 (42%). A majority of endoscopists had performed >2000 ERCPs in both groups (71% Exalt, 93% aScope Duodeno). Technical success was 92% in both groups (n=119 Exalt-group, n=66 aScope-Duodeno-group). The procedural complexity for the ERCP cases performed were: Grade 1: 35 cases (18%), Grade 2: 83 cases (41%), Grade 3: 65 cases (32%), and Grade 4: 18 cases (9%). Thirteen patients (10%) from the Exalt group and 16 patients (22%) from the aScope Duodeno group required conversion to a reusable duodenoscope. On a scale of 1 to 5, Exalt and aScope Duodeno, respectively, were rated: 2.31 versus 2.60 for location and visualization quality, 1.38 versus 1.57 for maneuverability based on papillary orientation, 1.48 versus 1.15 for suction/air control, and 2.31 versus 2.34 for elevator efficiency. None of the adverse events were related to the SDDs. CONCLUSIONS: The 2 SDDs were comparable. Further ongoing enhancements to these devices will improve maneuverability and clinical effectiveness.


Assuntos
Colangiopancreatografia Retrógrada Endoscópica , Duodenoscópios , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Duodenoscópios/efeitos adversos , Colangiopancreatografia Retrógrada Endoscópica/efeitos adversos
8.
Gastrointest Endosc ; 95(3): 482-488, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34678298

RESUMO

BACKGROUND AND AIMS: Lumen-apposing metal stents (LAMSs) provide an endoscopic method for management of walled-off necrosis (WON) and a gateway for the performance of endoscopic necrosectomy (EN). However, bleeding may occur in up to 20% of EN procedures. Predictive factors for bleeding in this patient population are unknown, and there is no agreed-on algorithm for the management of bleeding. The aim of this study was to evaluate preprocedural risk factors for bleeding in patients undergoing endoscopic drainage or EN for WON. METHODS: A retrospective cohort of patients undergoing EN for WON was reviewed. Demographics, comorbidities, concurrent medications, and etiology of pancreatitis were recorded. Pre-, peri-, and postprocedural clinical variables were compared using the χ2 test and independent t test. RESULTS: Between June 2014 and October 2020, 536 ENs were performed in 151 patients. Intraprocedural bleeding occurred during 28 procedures (5.2%) in 18 patients (11.9%). Endoscopic hemostasis was attempted in 8 patients (10 procedures). Eight patients (10 procedures) in total were treated by interventional radiology (IR). Thrombocytopenia (P = .006) and cirrhosis (P = .049) were associated with intraprocedural bleeding, although thrombocytopenia was present in only 1 patient. Identification of a vessel within the cavity endoscopically was also associated with bleeding (P < .001). On multivariate analysis, identification of a vessel within the cavity endoscopically remained a strong predictor of bleeding (P < .001), whereas cirrhosis was no longer significant. Patients who required IR for hemostasis were transfused with significantly more blood before the procedure than patients who did not (3.4 units vs .67 units, P = .002). CONCLUSIONS: EN for WON was associated with a 5.2% per-procedure risk of bleeding and an 11.9% per-patient bleeding risk. Identification of a vessel within the cavity during endoscopy is predictive of bleeding during EN. Patients who require more transfusions before endoscopy may require earlier intervention by IR.


Assuntos
Pancreatite Necrosante Aguda , Drenagem/métodos , Endoscopia/métodos , Humanos , Necrose/etiologia , Pancreatite Necrosante Aguda/etiologia , Estudos Retrospectivos , Stents/efeitos adversos , Centros de Atenção Terciária , Resultado do Tratamento
9.
Gastrointest Endosc ; 95(3): 471-479, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34562471

RESUMO

BACKGROUND AND AIMS: Direct endoscopic necrosectomy (DEN) of walled-off pancreatic necrosis (WOPN) lacks dedicated instruments and requires repetitive and cumbersome procedures. This study evaluated the safety and efficacy of a new powered endoscopic debridement (PED) system designed to simultaneously resect and remove solid debris within WOPN. METHODS: This was a single-arm, prospective, multicenter, international device trial conducted from November 2018 to August 2019 at 10 sites. Patients with WOPN ≥6 cm and ≤22 cm and with >30% solid debris were enrolled. The primary endpoint was safety through 21 days after the last DEN procedure. Efficacy outcomes included clearance of necrosis, procedural time, adequacy of debridement, number of procedures until resolution, hospital stay duration, and quality of life. RESULTS: Thirty patients (mean age, 55 years; 60% men) underwent DEN with no device-related adverse events. Of 30 patients, 15 (50%) achieved complete debridement in 1 session and 20 (67%) achieved complete debridement within 2 or fewer sessions. A median of 1.5 interventions (range, 1-7) were required. Median hospital stay was 10 days (interquartile range, 22). There was an overall reduction of 91% in percent necrosis within WOPN from baseline to follow-up and 85% in collection volume. Baseline WOPN volume was positively correlated with the total number of interventions (ρ = .363, P = .049). CONCLUSIONS: The new PED system seems to be a safe and effective treatment tool for WOPN, resulting in fewer interventions and lower hospital duration when compared with published data on using conventional instruments. Randomized controlled trials comparing the PED system with conventional DEN are needed. (Clinical trial registration number: NCT03694210.).


Assuntos
Pancreatite Necrosante Aguda , Drenagem/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Necrose/cirurgia , Pâncreas/cirurgia , Pancreatite Necrosante Aguda/cirurgia , Estudos Prospectivos , Qualidade de Vida , Estudos Retrospectivos , Stents , Resultado do Tratamento
10.
Gastrointest Endosc ; 94(4): 727-732, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-33957105

RESUMO

BACKGROUND AND AIMS: EUS-directed transgastric ERCP (the EDGE procedure) is a simplified method of performing ERCP in Roux-en-Y gastric bypass patients. The EDGE procedure involves placement of a lumen-apposing metal stent (LAMS) into the excluded stomach to serve as a conduit for passage of the duodenoscope for pancreatobiliary intervention. Originally a multistep process, urgent indications for ERCP have led to the development of single-session EDGE (SS-EDGE) with LAMS placement and ERCP performed in the same session. The goal of this study was to identify predictive factors of intraprocedural LAMS migration in SS-EDGE. METHODS: We conducted a multicenter retrospective review that included 9 tertiary medical centers across the United States. Data were collected and analyzed from 128 SS-EDGE procedures. The primary outcome was intraprocedural LAMS migration. Secondary outcomes were other procedural adverse events such as bleeding and perforation. RESULTS: Eleven LAMS migrations were observed in 128 procedures (8.6%). Univariate analysis of clinically relevant variables was performed, as was a binary logistic regression analysis of stent diameter and stent dilation. This revealed that use of a smaller (15 mm) diameter LAMS was an independent predictor of intraprocedural stent migration (odds ratio, 5.36; 95% confidence interval, 1.29-22.24; P = .021). Adverse events included 3 patients who required surgery and 2 who experienced intraprocedural bleeding. CONCLUSIONS: Use of a larger-diameter LAMS is a predictive factor for a nonmigrated stent and improved procedural success in SS-EDGE. Although larger patient cohorts are needed to adequately assess these findings, performance of LAMS dilation and fixation may also decrease risk of intraprocedural LAMS migration and improve procedural success.


Assuntos
Colangiopancreatografia Retrógrada Endoscópica , Derivação Gástrica , Colangiopancreatografia Retrógrada Endoscópica/efeitos adversos , Derivação Gástrica/efeitos adversos , Humanos , Estudos Retrospectivos , Stents , Estômago/cirurgia
11.
Endoscopy ; 53(6): 611-618, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-32882722

RESUMO

BACKGROUND: Endoscopic ultrasound-directed transgastric endoscopic retrograde cholangiopancreatography (ERCP; EDGE) is an alternative to enteroscopy- and laparoscopy-assisted ERCP in patients with Roux-en-Y gastric bypass anatomy. Although short-term results are promising, the long-term outcomes are not known. The aims of this study were: (1) to determine the rates of long-term adverse events after EDGE, with a focus on rates of persistent gastrogastric or jejunogastric fistula; (2) to identify predictors of persistent fistula; (3) to assess the outcomes of endoscopic closure when persistent fistula is encountered. METHODS: This was a multicenter retrospective study involving 13 centers between February 2015 and March 2019. Adverse events were defined according to the ASGE lexicon. Persistent fistula was defined as an upper gastrointestinal series or esophagogastroduodenoscopy showing evidence of fistula. RESULTS: 178 patients (mean age 58 years, 79 % women) underwent EDGE. Technical success was achieved in 98 % of cases (175/178), with a mean procedure time of 92 minutes. Periprocedural adverse events occurred in 28 patients (15.7 %; mild 10.1 %, moderate 3.4 %, severe 2.2 %). The four severe adverse events were managed laparoscopically. Persistent fistula was diagnosed in 10 % of those sent for objective testing (9/90). Following identification of a fistula, 5 /9 patients underwent endoscopic closure procedures, which were successful in all cases. CONCLUSIONS: The EDGE procedure is associated with high clinical success rates and an acceptable risk profile. Persistent fistulas after lumen-apposing stent removal are uncommon, but objective testing is recommended to identify their presence. When persistent fistulas are identified, endoscopic treatment is warranted, and should be successful in closing the fistula.


Assuntos
Colangiopancreatografia Retrógrada Endoscópica , Derivação Gástrica , Endoscopia Gastrointestinal , Endossonografia , Feminino , Derivação Gástrica/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
12.
J Surg Oncol ; 124(3): 343-353, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34120342

RESUMO

Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) is the preferred method for diagnosing pancreatic masses. While the diagnostic success of EUS-FNA is widely accepted, the actual performance of EUS-FNA is not known. This study sought to define the EUS-FNA accuracy compared with the gold standard, surgically resected specimens. The study was a single institution, retrospective, and chart review of patients with surgically resected pancreatic specimens from 2005 to 2015 with a preoperative EUS-FNA or biliary brushing. Cytological reports were organized from least concerning (i.e., low chance of malignancy) to most concerning (high chance of malignancy) into eight cytologic categories. We identified 741 cytologic cases: 530 EUS-FNA and 211 endoscopic brushings. For EUS-FNA samples, 62.5% of "benign" samples proved to be "benign" on surgical pathology. A cytologic diagnosis of "suspicious for malignancy" or "positive for malignancy" were concordant with a cancer diagnosis on surgical pathology 93.3% and 98.0% of cases, respectively. EUS-FNA proved to be highly reliable at diagnosing malignancy for cytologic samples that were "suspicious" or "positive" for malignancy. Paired with supportive clinical data, these interpretations may be used to justify cancer treatment.


Assuntos
Pancreatopatias/patologia , Pancreatopatias/cirurgia , Neoplasias Pancreáticas/patologia , Neoplasias Pancreáticas/cirurgia , Carcinoma Ductal Pancreático/diagnóstico por imagem , Carcinoma Ductal Pancreático/patologia , Carcinoma Ductal Pancreático/cirurgia , Diagnóstico Diferencial , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico , Humanos , Pancreatectomia , Pancreatopatias/diagnóstico por imagem , Neoplasias Pancreáticas/diagnóstico por imagem , Pancreaticoduodenectomia
13.
Gastroenterology ; 155(5): 1483-1494.e7, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30056094

RESUMO

BACKGROUND & AIMS: It is unclear whether participation in competency-based fellowship programs for endoscopic ultrasound (EUS) and endoscopic retrograde cholangiopancreatography (ERCP) results in high-quality care in independent practice. We measured quality indicator (QI) adherence during the first year of independent practice among physicians who completed endoscopic training with a systematic assessment of competence. METHODS: We performed a prospective multicenter cohort study of invited participants from 62 training programs. In phase 1, 24 advanced endoscopy trainees (AETs), from 20 programs, were assessed using a validated competence assessment tool. We used a comprehensive data collection and reporting system to create learning curves using cumulative sum analysis that were shared with AETs and trainers quarterly. In phase 2, participating AETs entered data into a database pertaining to every EUS and ERCP examination during their first year of independent practice, anchored by key QIs. RESULTS: By the end of training, most AETs had achieved overall technical competence (EUS 91.7%, ERCP 73.9%) and cognitive competence (EUS 91.7%, ERCP 94.1%). In phase 2 of the study, 22 AETs (91.6%) participated and completed a median of 136 EUS examinations per AET and 116 ERCP examinations per AET. Most AETs met the performance thresholds for QIs in EUS (including 94.4% diagnostic rate of adequate samples and 83.8% diagnostic yield of malignancy in pancreatic masses) and ERCP (94.9% overall cannulation rate). CONCLUSIONS: In this prospective multicenter study, we found that although competence cannot be confirmed for all AETs at the end of training, most meet QI thresholds for EUS and ERCP at the end of their first year of independent practice. This finding affirms the effectiveness of training programs. Clinicaltrials.gov ID NCT02509416.


Assuntos
Colangiopancreatografia Retrógrada Endoscópica , Competência Clínica , Endossonografia , Colangiopancreatografia Retrógrada Endoscópica/normas , Endossonografia/normas , Humanos , Curva de Aprendizado , Estudos Prospectivos , Indicadores de Qualidade em Assistência à Saúde
14.
Gastrointest Endosc ; 89(6): 1160-1168.e9, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30738985

RESUMO

BACKGROUND AND AIMS: Minimum EUS and ERCP volumes that should be offered per trainee in "high quality" advanced endoscopy training programs (AETPs) are not established. We aimed to define the number of procedures required by an "average" advanced endoscopy trainee (AET) to achieve competence in technical and cognitive EUS and ERCP tasks to help structure AETPs. METHODS: American Society for Gastrointestinal Endoscopy (ASGE)-recognized AETPs were invited to participate; AETs were graded on every fifth EUS and ERCP examination using a validated tool. Grading for each skill was done using a 4-point scoring system, and learning curves using cumulative sum analysis for overall, technical, and cognitive components of EUS and ERCP were shared with AETs and trainers quarterly. Generalized linear mixed-effects models with a random intercept for each AET were used to generate aggregate learning curves, allowing us to use data from all AETs to estimate the average learning experience for trainees. RESULTS: Among 62 invited AETPs, 37 AETs from 32 AETPs participated. Most AETs reported hands-on EUS (52%, median 20 cases) and ERCP (68%, median 50 cases) experience before starting an AETP. The median number of EUS and ERCPs performed per AET was 400 (range, 200-750) and 361 (range, 250-650), respectively. Overall, 2616 examinations were graded (EUS, 1277; ERCP-biliary, 1143; pancreatic, 196). Most graded EUS examinations were performed for pancreatobiliary indications (69.9%) and ERCP examinations for ASGE biliary grade of difficulty 1 (72.1%). The average AET achieved competence in core EUS and ERCP skills at approximately 225 and 250 cases, respectively. However, overall technical competence was achieved for grade 2 ERCP at about 300 cases. CONCLUSION: The thresholds provided for an average AET to achieve competence in EUS and ERCP may be used by the ASGE and AETPs in establishing the minimal standards for case volume exposure for AETs during their training. (Clinical trial registration number: NCT02509416.).


Assuntos
Colangiopancreatografia Retrógrada Endoscópica , Competência Clínica , Educação de Pós-Graduação em Medicina/normas , Endoscopia do Sistema Digestório/educação , Endossonografia , Bolsas de Estudo/normas , Gastroenterologia/educação , Curva de Aprendizado , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico , Humanos , Estudos Prospectivos , Esfinterotomia Endoscópica/educação
15.
Surg Endosc ; 33(4): 1260-1270, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30209610

RESUMO

BACKGROUND: Percutaneous cholecystostomy tube (PTGBD), endoscopic retrograde cholangiopancreatography with transpapillary gallbladder drainage (TP), and endoscopic ultrasound-guided transmural gallbladder drainage (EGBD) using lumen-apposing metal stents (LAMS) have been offered for gallbladder decompression for acute cholecystitis in high-risk surgical patients. Yet, there are limited data comparing these therapies. Our aim was to compare the safety and efficacy of EGBD to TP and PTGBD for gallbladder drainage. METHODS: We retrospectively collected high-risk surgical patients from six centers with acute cholecystitis who underwent gallbladder drainage by EGBD, TP, or PTGBD. Data included technical success (gallbladder drainage), clinical success (acute cholecystitis resolution), adverse events (AE), and follow-up. RESULTS: From 2010 to 2016, 372 patients underwent gallbladder drainage, with 146 by PTGBD, 124 by TP, and 102 drained by EGBD. Technical (98% vs. 88% vs. 94%; p = 0.004) and Clinical (97% vs. 90% vs. 80%; p < 0.001) success rates were significantly higher with PTGBD and EGBD compared to TP. PTGBD group had statistically significantly higher number of complications as compared to EGBD and TP groups (2 0% vs. 2% vs. 5%; p = 0.01). Mean hospital stay in the EGBD group was significantly less than TP and PTGBD (16 vs. 18 vs. 19 days; p = 0.01), while additional surgical intervention was significantly higher in the PTGBD group compared to the EGBD and TP groups (49% vs. 4% vs. 11%; p < 0.0001). CONCLUSIONS: EGBD with LAMS is an effective and safer alternative to TP and PTGBD for treatment of patients with acute cholecystitis who cannot undergo surgery. EGBD with LAMS has significantly lower overall AEs, hospital stay, and unplanned admissions compared to PTGBD. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT01522573.


Assuntos
Colangiopancreatografia Retrógrada Endoscópica/métodos , Colecistite Aguda/cirurgia , Colecistostomia/métodos , Drenagem/métodos , Endossonografia/métodos , Stents Metálicos Autoexpansíveis , Adulto , Idoso , Drenagem/efeitos adversos , Endossonografia/instrumentação , Feminino , Humanos , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco
17.
Gastrointest Endosc ; 87(6): 1499-1504, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29425886

RESUMO

BACKGROUND AND AIMS: ERCP performed through previously placed enteral stents is an uncommon procedure without a significant amount of supporting literature and with a wide reported range of technical success. The purpose of this study was to evaluate and better define the technical feasibility and safety of performing ERCP through enteral stents in patients with combined malignant biliary and gastric outlet obstruction. METHODS: We conducted a multicenter, retrospective study on 71 patients with combined gastric outlet and biliary obstruction who underwent ERCP through a previously placed enteral stent at 2 tertiary care centers. Outcomes included but were not limited to technical success, clinical success, need for repeat ERCP, adverse events, and survival time. RESULTS: Overall technical success was achieved in 60 of 71 patients (85%), with technical success of 40 of 46 (87%) in type I obstructions (gastric outlet obstruction above the ampulla), 16 of 21 (76%) in type II obstructions (gastric outlet obstruction at the level of the ampulla), and 4 of 4 (100%) in type III obstructions (gastric outlet obstruction distal to the ampulla). In general, patients who achieved technical success also achieved clinical success. Adverse events occurred in 3 patients (3/71): 2 patients with acute cholangitis and 1 patient with perforation. Average survival time after the procedure was 4.6 months overall. CONCLUSIONS: ERCP performed through enteral stents is safe, with a high technical and clinical success rate, but may be more technically challenging in the setting of type II obstructions. This procedure could be considered first line in the unique setting that a patient requires ERCP through a previously placed enteral stent for malignant gastric outlet and biliary obstruction.


Assuntos
Colangiopancreatografia Retrógrada Endoscópica/métodos , Colestase/cirurgia , Duodeno , Obstrução da Saída Gástrica/cirurgia , Complicações Pós-Operatórias/epidemiologia , Stents , Adulto , Idoso , Idoso de 80 Anos ou mais , Ampola Hepatopancreática , Neoplasias do Ducto Colédoco/complicações , Neoplasias do Ducto Colédoco/cirurgia , Neoplasias Duodenais/complicações , Neoplasias Duodenais/cirurgia , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias Pancreáticas/complicações , Neoplasias Pancreáticas/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
18.
Gastrointest Endosc ; 88(3): 486-494, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29730228

RESUMO

BACKGROUND AND AIMS: ERCP is challenging in patients with Roux-en-Y gastric bypass (RYGB) anatomy. EUS-guided gastrogastrostomy (GG) creation is a promising novel technique to access the excluded stomach to facilitate conventional ERCP. We aimed to compare procedural outcomes and adverse events (AEs) between EUS-guided GG-assisted ERCP (EUS-GG-ERCP) and enteroscopy-assisted ERCP (e-ERCP) in patients with RYGB. METHODS: Patients with RYGB anatomy who underwent EUS-GG-ERCP or e-ERCP between 2014 and 2016 at 5 tertiary centers were included. The primary outcome was technical success of ERCP, defined as successful cannulation of the selected duct with successful intervention as intended. Secondary outcomes included total procedural time (in the EUS-GG group, total procedural time included EUS-GG creation plus ERCP procedure time), length of hospital stay, and rate/severity of AEs graded according to the American Society for Gastrointestinal Endoscopy lexicon. RESULTS: A total of 60 patients (mean age, 57.2 ± 13.2; 75% women) were included, of whom 30 (50%) underwent EUS-GG-ERCP and 30 (50%) underwent e-ERCP (double-balloon enteroscope ERCP, 19; single-balloon enteroscope ERCP, 11). The technical success rate was significantly higher in the EUS-GG-ERCP versus the e-ERCP group (100% vs 60.0%, P < .001). Total procedure time was significantly shorter in patients who underwent EUS-GG-ERCP (49.8 minutes vs 90.7 minutes, P < .001). Postprocedure median length of hospitalization was shorter in the EUS-GG group (1 vs 10.5 days, P = .02). Rate of AEs was similar in both groups (10% vs 6.7%, P = 1). CONCLUSIONS: EUS-GG-ERCP may be superior to e-ERCP in patients with RYGB anatomy in terms of a higher technical success and shorter procedural times and offers a similar safety profile.


Assuntos
Colangiopancreatografia Retrógrada Endoscópica/métodos , Doenças do Sistema Digestório/terapia , Endoscopia Gastrointestinal , Endossonografia , Derivação Gástrica , Obesidade/cirurgia , Adulto , Idoso , Anastomose Cirúrgica , Doenças dos Ductos Biliares/complicações , Doenças dos Ductos Biliares/diagnóstico , Doenças dos Ductos Biliares/terapia , Doenças do Sistema Digestório/complicações , Doenças do Sistema Digestório/diagnóstico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Obesidade/complicações , Pancreatite/complicações , Pancreatite/diagnóstico , Pancreatite/terapia , Implantação de Prótese , Estudos Retrospectivos , Stents , Estômago/cirurgia
19.
J Ultrasound Med ; 37(1): 123-129, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28681437

RESUMO

OBJECTIVES: To use subharmonic imaging (SHI) to depict the vascularity of pancreatic masses compared to contrast-enhanced endoscopic ultrasound (EUS) and pathologic results. METHODS: Sixteen patients scheduled for biopsy of a pancreatic mass were enrolled in an Institutional Review Board-approved study. Pulse-inversion SHI (transmitting/receiving at 2.5/1.25 MHz) was performed on a LOGIQ 9 system (GE Healthcare, Milwaukee, WI) with a 4C transducer, whereas contrast harmonic EUS (transmitting/receiving at 4.7/9.4 MHz) was performed with a radial endoscope (GF-UTC180; Olympus Corporation, Tokyo, Japan) connected to a ProSound SSD α-10 scanner (Hitachi Aloka, Tokyo, Japan). Two injections of the contrast agent Definity (Lantheus Medical Imaging, North Billerica, MA) were administrated (0.3-0.4 and 0.6-0.8 mL for EUS and SHI, respectively). Contrast-to-tissue ratios (CTRs) in the mass and an adjacent vessel were calculated. Four physicians independently scored the images (benign to malignant) for diagnostic accuracy and inter-reader agreement. RESULTS: One patient dropped out before imaging, leaving 11 adenocarcinomas, 1 gastrointestinal stromal tumor with pancreatic infiltration, and 3 benign masses. Marked subharmonic signals were obtained in all patients, with intratumoral blood flow clearly visualized with SHI. Significantly greater CTRs were obtained in the masses with SHI than with EUS (mean ± SD, 1.71 ± 1.63 versus 0.63 ± 0.89; P = .016). There were no differences in the CTR in the surrounding vessels or when grouped by pathologic results (P > .60). The accuracies for contrast EUS and SHI were low (<53%), albeit with a greater κ value for SHI (0.34) than for EUS (0.13). CONCLUSIONS: Diagnostic accuracy of contrast EUS and transabdominal SHI for assessment of pancreatic masses was quite low in this pilot study. However, SHI had improved tumoral CTRs relative to contrast EUS.


Assuntos
Meios de Contraste , Endossonografia/métodos , Aumento da Imagem/métodos , Neoplasias Pancreáticas/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pâncreas/diagnóstico por imagem , Projetos Piloto , Reprodutibilidade dos Testes
20.
Gastrointest Endosc ; 86(3): 510-515, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28131864

RESUMO

BACKGROUND AND AIMS: Subepithelial lesions are found in about 1% of all EGD procedures, and GI stromal tumors are a type of subepithelial lesion commonly encountered. Although the majority of subepithelial lesions are benign, GI stromal tumors have malignant potential, making a definitive diagnosis important. Currently, the criterion standard for the diagnosis of GI stromal tumors is EUS-directed FNA (EUS-FNA). The definitive diagnosis of GI stromal tumors relies on immunohistochemical staining, which depends on enough tissue being submitted to the pathologist. Achieving adequate tissue acquisition from suspected GI stromal tumors by EUS-FNA remains a limitation. Advancements in needle design, however, have improved tissue acquisition and therefore may improve the definitive diagnosis of GI stromal tumors by EUS-FNA. The goal of this study is to compare a fine-needle biopsy (FNB) needle (SharkCore, Medtronics) with FNA needles in definitively diagnosing suspected GI stromal tumors. METHODS: This is a retrospective, single-center study of consecutive patients with suspected GI stromal tumors by EUS characterization who underwent EUS-FNA or EUS-FNB. RESULTS: A total of 106 patients (53 men, mean [± standard deviation {SD}] age 62.19 ± 16.33 years) were included in the study undergoing EUS-FNA or EUS-FNB of suspected GI stromal tumors. The needle size that was used most often was 22 gauge in both groups. The average size of the lesions was 27.68 ± 15.70 mm; 71.7% of lesions were located in stomach, 19.8% in the esophagus, 5.7% in the duodenum, and 2.8% in the rectosigmoid colon. Ninety-one patients underwent EUS-FNA and 15 patients underwent EUS-FNB. Adequate tissue was procured, allowing immunohistochemical staining in 59 (64.8%) patients in the FNA group and 15 (100%) patients in the FNB group; P = .006. A diagnosis was reached by immunohistochemical staining in 48 (52.7%) patients in the FNA group and 13 (86.7%) patients in the FNB group; P = .01. Tissue was insufficient to make a cytologic diagnosis in 22 (24.2%) patients in the FNA group compared with none in the FNB group; P = .03. Adequate tissue was procured on the first pass of the FNB needle in the majority of patients (83.3%), whereas only 23.5% of patients had adequate tissue on the first pass by the FNA needle, with a median of 3 passes; P = .00. Tissue was insufficient to perform immunohistochemical staining, and thus a diagnosis could not be confirmed before surgery in 8 of the 34 surgical patients in the FNA group. Ten of 15 patients in the EUS-FNB group underwent surgery, all of whom were correctly diagnosed by FNB. There were no reported immediate adverse events or technical difficulties in either group. CONCLUSIONS: EUS-FNB by using a SharkCore needle for suspected GI stromal tumors is technically similar and equally safe as FNA, with better tissue acquisition, which was achieved with fewer needle passes and an improved diagnostic yield by immunohistochemical staining.


Assuntos
Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/instrumentação , Neoplasias Gastrointestinais/patologia , Tumores do Estroma Gastrointestinal/patologia , Agulhas , Idoso , Neoplasias Duodenais/diagnóstico , Neoplasias Duodenais/patologia , Endoscopia Gastrointestinal/instrumentação , Endoscopia Gastrointestinal/métodos , Neoplasias Esofágicas/diagnóstico , Neoplasias Esofágicas/patologia , Feminino , Tumores do Estroma Gastrointestinal/diagnóstico , Humanos , Imuno-Histoquímica , Masculino , Pessoa de Meia-Idade , Neoplasias Retais/diagnóstico , Neoplasias Retais/patologia , Estudos Retrospectivos , Neoplasias do Colo Sigmoide/diagnóstico , Neoplasias do Colo Sigmoide/patologia , Neoplasias Gástricas/diagnóstico , Neoplasias Gástricas/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA