Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 75
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Europace ; 26(10)2024 Oct 03.
Artigo em Inglês | MEDLINE | ID: mdl-39177260

RESUMO

AIMS: The effective refractory period (ERP) is one of the main electrophysiological properties governing arrhythmia, yet ERP personalization is rarely performed when creating patient-specific computer models of the atria to inform clinical decision-making. This study evaluates the impact of integrating clinical ERP measurements into personalized in silico models on arrhythmia vulnerability. METHODS AND RESULTS: Clinical ERP measurements were obtained in seven patients from multiple locations in the atria. Atrial geometries from the electroanatomical mapping system were used to generate personalized anatomical atrial models. The Courtemanche M. et al. cellular model was adjusted to reproduce patient-specific ERP. Four modeling approaches were compared: homogeneous (A), heterogeneous (B), regional (C), and continuous (D) ERP distributions. Non-personalized approaches (A and B) were based on literature data, while personalized approaches (C and D) were based on patient measurements. Modeling effects were assessed on arrhythmia vulnerability and tachycardia cycle length, with sensitivity analysis on ERP measurement uncertainty. Mean vulnerability was 3.4 ± 4.0%, 7.7 ± 3.4%, 9.0 ± 5.1%, and 7.0 ± 3.6% for scenarios A-D, respectively. Mean tachycardia cycle length was 167.1 ± 12.6 ms, 158.4 ± 27.5 ms, 265.2 ± 39.9 ms, and 285.9 ± 77.3 ms for scenarios A-D, respectively. Incorporating perturbations to the measured ERP in the range of 2, 5, 10, 20, and 50 ms changed the vulnerability of the model to 5.8 ± 2.7%, 6.1 ± 3.5%, 6.9 ± 3.7%, 5.2 ± 3.5%, and 9.7 ± 10.0%, respectively. CONCLUSION: Increased ERP dispersion had a greater effect on re-entry dynamics than on vulnerability. Inducibility was higher in personalized scenarios compared with scenarios with uniformly reduced ERP; however, this effect was reversed when incorporating fibrosis informed by low-voltage areas. Effective refractory period measurement uncertainty up to 20 ms slightly influenced vulnerability. Electrophysiological personalization of atrial in silico models appears essential and requires confirmation in larger cohorts.


Assuntos
Potenciais de Ação , Átrios do Coração , Modelos Cardiovasculares , Modelagem Computacional Específica para o Paciente , Período Refratário Eletrofisiológico , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Átrios do Coração/fisiopatologia , Idoso , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Frequência Cardíaca , Fatores de Tempo , Técnicas Eletrofisiológicas Cardíacas , Valor Preditivo dos Testes , Simulação por Computador
2.
J Cardiovasc Electrophysiol ; 34(4): 833-840, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36786515

RESUMO

INTRODUCTION: Pulmonary vein isolation (PVI) is well established as a primary treatment for atrial fibrillation (AF). The POLAR ICE study was designed to collect prospective real world data on the safety and effectiveness of the POLARxTM cryoballoon for PVI to treat paroxysmal AF. METHODS: POLAR ICE, a prospective, non-randomized, multicenter (international) registry (NCT04250714), enrolled 399 patients across 19 European centers. Procedural characteristics, such as time to isolation, cryoablations per pulmonary vein (PV), balloon nadir temperature, and occlusion grade were recorded. PVI was confirmed with entrance block testing. RESULTS: Data on 372 de novo PVI procedures (n = 2190 ablations) were collected. Complete PVI was achieved in 96.8% of PVs. Procedure and fluoroscopy times were 68.2 ± 24.6 and 15.6 ± 9.6 min, respectively. Left atrial dwell time was 46.6 ± 18.3 min. Grade 3 or 4 occlusion was achieved in 98.2% of PVs reported and 71.2% of PVs isolation required only a single cryoablation. Of 2190 cryoapplications, 83% had a duration of at least 120 s; nadir temperature of these ablations averaged -56.3 ± 6.5°C. There were 6 phrenic nerve palsy events, 2 of which resolved within 3 months of the procedure. CONCLUSION: This real-world usage data on a novel cryoballoon suggests this device is effective, safe, and relatively fast in centers with cryoballoon experience. These data are comparable to prior POLARx reports and in keeping with reported data on other cryoballoons. Future studies should examine the long-term outcomes and the relationship between biophysical parameters and outcomes for this novel cryoballoon.


Assuntos
Fibrilação Atrial , Humanos , Fibrilação Atrial/cirurgia , Estudos Prospectivos , Resultado do Tratamento , Átrios do Coração , Fluoroscopia
3.
Europace ; 24(6): 959-969, 2022 07 15.
Artigo em Inglês | MEDLINE | ID: mdl-34922350

RESUMO

AIMS: Bipolar radiofrequency ablation (B-RFA) has been reported as a bail-out strategy for the treatment of therapy refractory ventricular arrhythmias (VA). Currently, existing setups have not been standardized for B-RFA, while the impact of conventional B-RFA approaches on lesion formation remains unclear. METHODS AND RESULTS: (i) In a multicentre observational study, patients undergoing B-RFA for previously therapy-refractory VA using a dedicated B-RFA setup were retrospectively analysed. (ii) Additionally, in an ex vivo model lesion formation during B-RFA was evaluated using porcine hearts. In a total of 26 procedures (24 patients), acute success was achieved in all 14 ventricular tachycardia (VT) procedures and 7/12 procedures with premature ventricular contractions (PVC), with major complications occurring in 1 procedure (atrioventricular block). During a median follow-up of 211 days in 21 patients, 6/11 patients (VT) and 5/10 patients (PVC) remained arrhythmia-free. Lesion formation in the ex vivo model during energy titration from 30 to 50 W led to similar lesion volumes compared with initial high-power 50 W B-RFA. Lesion size significantly increased when combining sequential unipolar and B-RFA (1429 mm3 vs. titration 501 mm3 vs. B-RFA 50 W 423 mm3, P < 0.001), an approach used in overall 58% of procedures and more frequently applied in procedures without VA recurrence (92% vs. 36%, P = 0.009). Adipose tissue severely limited lesion formation during B-RFA. CONCLUSION: Using a dedicated device for B-RFA for therapy-refractory VA appears feasible and safe. While some patients need repeat ablation, success rates were encouraging. Sequential unipolar and B-RFA may be favourable for lesion formation.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Complexos Ventriculares Prematuros , Animais , Ablação por Cateter/métodos , Estudos Retrospectivos , Suínos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Resultado do Tratamento , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/cirurgia
4.
Europace ; 24(7): 1186-1194, 2022 07 21.
Artigo em Inglês | MEDLINE | ID: mdl-35045172

RESUMO

AIMS: Atrial flutter (AFlut) is a common re-entrant atrial tachycardia driven by self-sustainable mechanisms that cause excitations to propagate along pathways different from sinus rhythm. Intra-cardiac electrophysiological mapping and catheter ablation are often performed without detailed prior knowledge of the mechanism perpetuating AFlut, likely prolonging the procedure time of these invasive interventions. We sought to discriminate the AFlut location [cavotricuspid isthmus-dependent (CTI), peri-mitral, and other left atrium (LA) AFlut classes] with a machine learning-based algorithm using only the non-invasive signals from the 12-lead electrocardiogram (ECG). METHODS AND RESULTS: Hybrid 12-lead ECG dataset of 1769 signals was used (1424 in silico ECGs, and 345 clinical ECGs from 115 patients-three different ECG segments over time were extracted from each patient corresponding to single AFlut cycles). Seventy-seven features were extracted. A decision tree classifier with a hold-out classification approach was trained, validated, and tested on the dataset randomly split after selecting the most informative features. The clinical test set comprised 38 patients (114 clinical ECGs). The classifier yielded 76.3% accuracy on the clinical test set with a sensitivity of 89.7%, 75.0%, and 64.1% and a positive predictive value of 71.4%, 75.0%, and 86.2% for CTI, peri-mitral, and other LA class, respectively. Considering majority vote of the three segments taken from each patient, the CTI class was correctly classified at 92%. CONCLUSION: Our results show that a machine learning classifier relying only on non-invasive signals can potentially identify the location of AFlut mechanisms. This method could aid in planning and tailoring patient-specific AFlut treatments.


Assuntos
Flutter Atrial , Ablação por Cateter , Flutter Atrial/diagnóstico , Flutter Atrial/etiologia , Flutter Atrial/cirurgia , Eletrocardiografia/métodos , Sistema de Condução Cardíaco , Humanos , Aprendizado de Máquina
5.
J Cardiovasc Electrophysiol ; 32(3): 580-587, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33492749

RESUMO

INTRODUCTION: Recently a novel cryoballoon system (POLARx, Boston Scientific) became available for the treatment of atrial fibrillation. This cryoballoon is comparable with Arctic Front Advance Pro (AFA-Pro, Medtronic), however, it maintains a constant balloon pressure. We compared the procedural efficacy and biophysical characteristics of both systems. METHODS: One hundred and ten consecutive patients who underwent first-time cryoballoon ablation (POLARx: n = 57; AFA-Pro: n = 53) were included in this prospective cohort study. RESULTS: Acute isolation was achieved in 99.8% of all pulmonary veins (POLARx: 99.5% vs. AFA-Pro: 100%, p = 1.00). Total procedure time (81 vs. 67 min, p < .001) and balloon in body time (51 vs. 35 min, p < .001) were longer with POLARx. After a learning curve, these times were similar. Cryoablation with POLARx was associated with shorter time to balloon temperature -30°C (27 vs. 31 s, p < .001) and -40°C (32 vs. 54 s, p < .001), lower balloon nadir temperature (-55°C vs. -47°C, p < .001), and longer thawing time till 0°C (16 vs. 9 s, p < .001). There were no differences in time-to-isolation (TTI; POLARx: 45 s vs. AFA-Pro 43 s, p = .441), however, POLARx was associated with a lower balloon temperature at TTI (-46°C vs. -37°C, p < .001). Factors associated with acute isolation differed between groups. The incidence of phrenic nerve palsy was comparable (POLARx: 3.5% vs. AFA-Pro: 3.7%). CONCLUSION: The novel cryoballoon is comparable to AFA-Pro and requires only a short learning curve to get used to the slightly different handling. It was associated with faster cooling rates and lower balloon temperatures but TTI was similar to AFA-Pro.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Boston , Criocirurgia/efeitos adversos , Humanos , Estudos Prospectivos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Resultado do Tratamento
6.
Europace ; 23(23 Suppl 1): i133-i142, 2021 03 04.
Artigo em Inglês | MEDLINE | ID: mdl-33751084

RESUMO

AIMS: The treatment of atrial fibrillation beyond pulmonary vein isolation has remained an unsolved challenge. Targeting regions identified by different substrate mapping approaches for ablation resulted in ambiguous outcomes. With the effective refractory period being a fundamental prerequisite for the maintenance of fibrillatory conduction, this study aims at estimating the effective refractory period with clinically available measurements. METHODS AND RESULTS: A set of 240 simulations in a spherical model of the left atrium with varying model initialization, combination of cellular refractory properties, and size of a region of lowered effective refractory period was implemented to analyse the capabilities and limitations of cycle length mapping. The minimum observed cycle length and the 25% quantile were compared to the underlying effective refractory period. The density of phase singularities was used as a measure for the complexity of the excitation pattern. Finally, we employed the method in a clinical test of concept including five patients. Areas of lowered effective refractory period could be distinguished from their surroundings in simulated scenarios with successfully induced multi-wavelet re-entry. Larger areas and higher gradients in effective refractory period as well as complex activation patterns favour the method. The 25% quantile of cycle lengths in patients with persistent atrial fibrillation was found to range from 85 to 190 ms. CONCLUSION: Cycle length mapping is capable of highlighting regions of pathologic refractory properties. In combination with complementary substrate mapping approaches, the method fosters confidence to enhance the treatment of atrial fibrillation beyond pulmonary vein isolation particularly in patients with complex activation patterns.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Simulação por Computador , Átrios do Coração , Frequência Cardíaca , Humanos , Veias Pulmonares/cirurgia
7.
Europace ; 23(7): 1042-1051, 2021 07 18.
Artigo em Inglês | MEDLINE | ID: mdl-33550380

RESUMO

AIMS: Radiofrequency ablation creates irreversible cardiac damage through resistive heating and this temperature change results in a generator impedance drop. Evaluation of a novel local impedance (LI) technology measured exclusively at the tip of the ablation catheter found that larger LI drops were indicative of more effective lesion formation. We aimed to evaluate whether LI drop is associated with conduction block in patients with paroxysmal atrial fibrillation (AF) undergoing pulmonary vein isolation (PVI). METHODS AND RESULTS: Sixty patients underwent LI-blinded de novo PVI using a point-by-point ablation workflow. Pulmonary vein rings were divided into 16 anatomical segments. After a 20-min waiting period, gaps were identified on electroanatomic maps. Median LI drop within segments with inter-lesion distance ≤6 mm was calculated offline. The diagnostic accuracy of LI drop for predicting segment block was assessed using receiver operating characteristic analysis. For segments with inter-lesion distance ≤6 mm, acutely blocked segments had a significantly larger LI drop [19.8 (14.1-27.1) Ω] compared with segments with gaps [10.6 (7.8-14.7) Ω, P < 0.001). In view of left atrial wall thickness differences, the association between LI drop and block was further evaluated for anterior/roof and posterior/inferior segments. The optimal LI cut-off value for anterior/roof segments was 16.1 Ω (positive predictive value for block: 96.3%) and for posterior/inferior segments was 12.3 Ω (positive predictive value for block: 98.1%) where inter-lesion distances were ≤6 mm. CONCLUSION: The magnitude of LI drop was predictive of acute PVI segment conduction block in patients with paroxysmal AF. The thinner posterior wall required smaller LI drops for block compared with the thicker anterior wall.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Catéteres , Impedância Elétrica , Humanos , Veias Pulmonares/cirurgia , Resultado do Tratamento
8.
Herz ; 45(7): 663-667, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33026483

RESUMO

BACKGROUND: Several observational studies have suggested a worrying reduction in hospitalisations for acute coronary syndromes in the emergency cardiology department in the last few months all over the world. The aim of the present study is to assess the impact of the current COVID-19 health crisis on admission for acute coronary syndrome (ACS) in the cardiology department of a tertiary general hospital in Germany with a COVID-19 ward. METHODS AND RESULTS: The authors retrieved clinical data evaluating consecutive patients with ACS admitted to their emergency cardiology department. Data from January to June 2020, as well as for a 5-week period corresponding to this year's COVID-19 outbreak in south-west Germany (23rd March-26th April), were analysed and compared to data from equivalent weeks in the previous 2 years. A trend of reduction in admissions for ACS was observed from the beginning of the outbreak in the region at the end of March 2020. This trend continued and even intensified after a fall in COVID-19 cases in the area; the number of ACS patients in April 2020 was 25% and in June 29% lower than in January 2020 (p-value for linear trend <0.001). An even more consistent reduction was observed as compared with the equivalent weeks in the previous 2 years (38% and 30% lower than in 2019 and 2018, respectively; p = 0.009). CONCLUSIONS: The COVID-19 health and social crisis has caused a worrying trend of reduced cardiological admissions for ACS, without evidence of a decrease in its incidence. Understanding and counteracting the causes appears to be crucial to avoiding major long-term consequences for healthcare systems worldwide.


Assuntos
Síndrome Coronariana Aguda/epidemiologia , Infecções por Coronavirus/epidemiologia , Pneumonia Viral/epidemiologia , Betacoronavirus , COVID-19 , Alemanha/epidemiologia , Hospitalização , Humanos , Pandemias , Estudos Retrospectivos , SARS-CoV-2 , Centros de Atenção Terciária
9.
BMC Cardiovasc Disord ; 18(1): 71, 2018 04 27.
Artigo em Inglês | MEDLINE | ID: mdl-29703158

RESUMO

BACKGROUND: There is a lack of data on anticoagulation requirements during ablation of atrial fibrillation (AF). This study compares different oral anticoagulation (OAC) strategies to evaluate risk of bleeding and thromboembolic complications. METHODS: We conducted a single-centre study in patients undergoing left atrial ablation of AF. Three groups were defined: 1) bridging: interrupted vitamin-K-antagonists (VKA), INR ≤2, and bridging with heparin; 2) VKA: uninterrupted VKA and INR of > 2; 3) DOAC: uninterrupted direct oral anticoagulants. Bleeding complications, thromboembolic events and peri-procedural heparin doses were assessed. RESULTS: In total, 780 patients were documented. At 48 h, major complications were more common in the bridging group compared to uninterrupted VKA and DOAC groups (OR: 3.42, 95% CI: 1.29-9.10 and OR: 3.01, 95% CI: 1.19-7.61), largely driven by differences in major pericardial effusion (OR: 4.86, 95% CI: 1.56-15.99 and OR: 4.466, 95% CI, 1.52-13.67) and major vascular events (OR: 2.92, 95% CI: 0.58-14.67 and OR: 9.72, 95% CI: 1.00-94.43). Uninterrupted VKAs and DOACs resulted in similar odds of major complications (overall OR: 1.14, 95% CI: 0.44-2.92), including cerebrovascular events (OR: 1.21, 95% CI: 0.27-5.45). However, whereas only TIAs were observed in DOAC and bridging groups, strokes also occurred in the VKA group. Rates of minor complications (pericardial effusion, vascular complications, gastrointestinal hemorrhage) and major/minor groin hemorrhage were similar across groups. CONCLUSION: Our dataset illustrates that uninterrupted VKA and DOAC have a better risk-benefit profile than VKA bridging. Bridging was associated with a 4.5× increased risk of complications and should be avoided, if possible.


Assuntos
Anticoagulantes/administração & dosagem , Fibrilação Atrial/cirurgia , Ablação por Cateter , Vitamina K/antagonistas & inibidores , Administração Oral , Idoso , Anticoagulantes/efeitos adversos , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Esquema de Medicação , Feminino , Alemanha , Hemorragia/induzido quimicamente , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Tromboembolia/etiologia , Tromboembolia/prevenção & controle , Fatores de Tempo , Resultado do Tratamento
10.
Europace ; 19(3): 378-384, 2017 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-27702864

RESUMO

AIMS: Radiofrequency (RF) ablation represents a standard of care for pulmonary vein isolation in patients with drug-refractory paroxysmal atrial fibrillation (AF). In this setting, cryoballoon (CB) ablation has emerged as alternative therapy. However, the efficacy and safety of CB vs. RF ablation in patients with paroxysmal AF remain a matter of debate. METHODS AND RESULTS: We searched electronic scientific databases for studies of CB vs. RF ablation in patients with paroxysmal AF. Aggregate data were pooled to perform a meta-analysis. The primary efficacy and safety outcomes were the recurrence of any atrial arrhythmia and procedure-related complications, respectively. A total of 6473 participants from 10 studies (CB, n = 2232 vs. RF, n = 4241) were studied. After a median follow-up of 16 months, the risk of any atrial arrhythmia recurrence (risk ratio, RR 95% confidence interval [95% CI] = 1.01 [0.90-1.14], P = 0.83) and procedure-related complications (RR [95% CI] = 0.92 [0.66-1.28], P = 0.61) were comparable between CB vs. RF ablation. Cryoballoon ablation led to a higher risk of persistent phrenic nerve palsy (RR [95% CI] = 13.60 [3.87-47.81], P < 0.01) and a lower risk of cardiac tamponade (RR [95% CI] = 0.48 [0.25-0.89], P = 0.02) compared with RF ablation. There was a trend of statistically significant interaction between the type of CB and the duration of ablation (P for interaction = 0.09). CONCLUSION: In patients with paroxysmal AF, ablation therapy with CB is associated with efficacy and safety comparable to that of RF. Second-generation CB catheters seem to reduce procedure duration. Further studies are warranted to disclose the impact of second-generation CB catheters compared with RF for ablation of paroxysmal AF.


Assuntos
Fibrilação Atrial/cirurgia , Cateteres Cardíacos , Ablação por Cateter , Criocirurgia/instrumentação , Veias Pulmonares/cirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Distribuição de Qui-Quadrado , Criocirurgia/efeitos adversos , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Observacionais como Assunto , Razão de Chances , Veias Pulmonares/fisiopatologia , Ensaios Clínicos Controlados Aleatórios como Assunto , Recidiva , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
11.
BMC Cardiovasc Disord ; 17(1): 135, 2017 05 25.
Artigo em Inglês | MEDLINE | ID: mdl-28545407

RESUMO

BACKGROUND: Effective treatment of paroxysmal atrial fibrillation (AF) is essential for reducing the risk of stroke and heart failure. Cryoballoon (CB) ablation has been developed as an alternative to the use of radiofrequency (RF) energy for electrical isolation of the pulmonary veins. Herein, we provide long-term data regarding the efficacy of CB ablation in comparison to RF. METHODS: FreezeAF was a randomised non-inferiority study comparing CB ablation with RF ablation for the treatment of patients with drug-refractory paroxysmal AF. Procedural success for the long-term follow-up (30 months) was defined as freedom from AF with an absence of persistent complications. RESULTS: Of the 315 patients that were randomised and received catheter ablation, 292 (92.7%) completed the 30-month follow-up (147 in the RF group and 145 in the CB group). The baseline characteristics of the RF and CB groups were similar. Single-procedure success was achieved by 40% of patients in the RF group and 42% of the CB group (p < 0.001 for non-inferiority). When including re-do procedures in the analysis, the multiple procedure success rate was 72% in the RF group and 76% in the CB group. CONCLUSION: The data provide long-term evidence that CB ablation is non-inferior to RF ablation, with high proportions of patients reporting freedom from AF 30 months after the index procedure. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT00774566 ; first registered October 16, 2008; first patient included October 20, 2008.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Criocirurgia , Veias Pulmonares/cirurgia , Irrigação Terapêutica , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Criocirurgia/efeitos adversos , Criocirurgia/instrumentação , Intervalo Livre de Doença , Feminino , Alemanha , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Veias Pulmonares/fisiopatologia , Recidiva , Irrigação Terapêutica/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
12.
Circulation ; 132(14): 1311-9, 2015 Oct 06.
Artigo em Inglês | MEDLINE | ID: mdl-26283655

RESUMO

BACKGROUND: There is a lack of data on the comparative efficacy and procedural safety of open irrigated radiofrequency (RF) and cryoballoon catheter (CB) ablation for pulmonary vein isolation in patients with paroxysmal atrial fibrillation. METHODS AND RESULTS: In a prospective, noninferiority study, 315 patients were randomly assigned to RF (n=159) or CB (n=156) ablation. The primary end point was freedom from atrial arrhythmia with absence of persistent complications. Patients were largely comparable between groups with more vascular disease in the RF group (8.2% versus 2.6% for CB; P=0.028). The primary end point at 12 months was achieved by 70.7% with RF and 73.6% with CB (multiple procedure success), including 31 redo procedures in each group (19.5% of RF versus 19.9% of CB; P=0.933). For the intention-to-treat population, noninferiority of CB was revealed for the predefined inferiority margin (risk difference, 0.029; 95% confidence interval, -0.074 to 0.132; P<0.001). Rates at 6 months were 63.1% and 64.1% for the RF and CB groups (single procedure success), and noninferiority was confirmed (risk difference, 0.010; 95% confidence interval, -0.097 to 0.116; P=0.002). Periprocedural complications for the index procedure were more frequent in the CB group (5.0% RF, 12.2% CB; P=0.022) with a significant difference in phrenic nerve palsies (0% RF, 5.8% CB; P=0.002). CONCLUSION: This large, prospective, randomized, controlled study demonstrates noninferiority of CB ablation versus RF ablation for treating patients with paroxysmal atrial fibrillation. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT00774566.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Criocirurgia/métodos , Veias Pulmonares/cirurgia , Antagonistas Adrenérgicos beta/uso terapêutico , Idoso , Anticoagulantes/efeitos adversos , Anticoagulantes/uso terapêutico , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/epidemiologia , Doenças Cardiovasculares/epidemiologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/instrumentação , Terapia Combinada , Comorbidade , Criocirurgia/efeitos adversos , Criocirurgia/instrumentação , Diabetes Mellitus/epidemiologia , Eletrocardiografia Ambulatorial , Feminino , Humanos , Imageamento Tridimensional , Complicações Intraoperatórias/epidemiologia , Complicações Intraoperatórias/etiologia , Masculino , Pessoa de Meia-Idade , Derrame Pericárdico/epidemiologia , Derrame Pericárdico/etiologia , Nervo Frênico/lesões , Hemorragia Pós-Operatória/induzido quimicamente , Estudos Prospectivos , Medição de Risco , Tamanho da Amostra , Trombofilia/tratamento farmacológico , Trombofilia/etiologia , Resultado do Tratamento
13.
Catheter Cardiovasc Interv ; 86(4): 738-44, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25641398

RESUMO

OBJECTIVES: To assess outcomes for patients undergoing transcatheter aortic valve implantation (TAVI) versus surgical aortic valve replacement but with less than high risk. BACKGROUND: While there is abundant data for high risk patients there is insufficient data for reduced risk. METHODS: Patients undergoing TAVI or SAVR between 2007 and 2012 in Karlsruhe were considered. They were assessed by cardiac computed tomography, transoesophageal echocardiogram, and logistic EuroSCORE I (ES) and groups compared using Propensity Score Matching. RESULTS: The mean ES was 10.1±2.8 in the TAVI group (n = 419) and 5.7 ± 3.2 in the SAVR group (n = 722; P < 0.0001). Mean survival probability over 3 years was higher in patients undergoing surgery (P < 0.0001). A total of 432 patients were considered for the matched-pairs analysis based on propensity scores (216 in each group). Major vascular complications (10.6% vs. 0.0%; P < 0.0001), new pacemaker implantation (13.9% vs. 4.6%; P < 0.001) and moderate aortic insufficiency (3.2% vs. 0.5%; P = 0.03) were more frequent in patients undergoing TAVI. Major (20.8% vs. 4.2%; P < 0.0001) and life-threatening (14.5% vs. 2.3%; P < 0.0001) bleeding complications were more frequent in those undergoing surgery. Survival probability over 3 years in the propensity matched cohort was comparable between both groups (P = 0.16). CONCLUSIONS: In this large, single center, real world dataset there was no difference in mortality between patients undergoing TAVI or SAVR during a 3-year follow-up but there was a TAVI related increase in major vascular complications, new pacemaker implantation and aortic insufficiency and a SAVR related increased bleeding risk.


Assuntos
Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/métodos , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Procedimentos Cirúrgicos Cardíacos/métodos , Procedimentos Cirúrgicos Cardíacos/mortalidade , Estudos de Coortes , Ecocardiografia Doppler/métodos , Feminino , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Pontuação de Propensão , Sistema de Registros , Estudos Retrospectivos , Medição de Risco , Índice de Gravidade de Doença , Fatores Sexuais , Análise de Sobrevida , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
14.
J Interv Cardiol ; 28(1): 82-9, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25495073

RESUMO

The new balloon-expandable Edwards SAPIEN 3 THV has significant design improvements requiring adjustments in the implantation technique as compared to the previous generation SAPIEN XT. Basically, the new valve requires less oversizing due to the outer skirt, which, if positioned underneath the annulus, can reduce the occurrence and severity of paravalvular leak (PVL). As with any transcatheter vale, a thorough assessment of the device-landing-zone, the surrounding structures, and the distribution of calcifications is of vast importance. Once the SAPIEN 3 valve is positioned with the initial orientation of the middle balloon marker at the level of the leaflet hinge points, the outer skirt will remain under the annulus, despite the foreshortening of the lower inflow portion of the valve. If there is an incomplete apposition, the outer skirt can conform to the anatomy, close the gaps, and reduce the risk of PVL. When calcifications are located on the edges of the annulus, PVL is common with the SAPIEN XT THV but dramatically reduced with the SAPIEN 3 THV. If the calcification extends from the annulus into the entire LVOT, there is always an incomplete apposition of the either valve frame; however, the resulting PVL is reduced by the outer skirt of the SAPIEN 3. In 165 consecutive SAPIEN 3 patients, 89.7% (n = 145) had none or a trace PVL and there were no patients with moderate or severe PVL. The new generation SAPIEN 3 valve allows more challenging anatomies to be treated, requires less oversizing, and can reduce PVL.


Assuntos
Estenose da Valva Aórtica/cirurgia , Bioprótese , Próteses Valvulares Cardíacas , Desenho de Prótese , Ajuste de Prótese , Substituição da Valva Aórtica Transcateter/métodos , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Seleção de Pacientes , Calcificação Vascular/complicações
15.
Europace ; 17(3): 447-52, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25564547

RESUMO

AIMS: The modified anterior line (MAL) is an alternative to the mitral isthmus (MI) line for the treatment of perimitral atrial flutter (PMFL). We sought to investigate acute and long-term efficacy of this line if routinely used for PMFL. METHODS AND RESULTS: The cohort included 77 consecutive patients who underwent catheter ablation of PMFL. The anterior line was deployed between the anterolateral mitral annulus and the ostium of the left superior pulmonary vein. Perimitral atrial flutter was either the presenting arrhythmia after persistent atrial fibrillation (AF) ablation (Group 1, n = 42, 54.5%), occurring during AF ablation (Group 2, n = 25, 35%) or presenting as primary arrhythmia (Group 3, n = 8, 10%). Acute success was defined as PMFL termination during MAL deployment with demonstration of bidirectional line block. Acute success was achieved in 68 of 77 patients (88%) without difference between the three groups. In five patients an additional MI line was necessary to terminate PMFL and in four patients both lines failed to achieve termination. During follow-up (16 ± 7 months), 38 of 77 (49%) patients underwent a repeat procedure for a recurrent arrhythmia. During reablation, 13 of 38 (34%) patients were identified to have a PMFL recurrence. Persistent MAL block was demonstrated in 22 of 38 (58%) patients during the repeat ablation. CONCLUSION: The MAL is effective for acute and long-term treatment of PMFL. Maintenance of bidirectional MAL block was shown in 58% of patients during a repeat ablation.


Assuntos
Flutter Atrial/cirurgia , Ablação por Cateter/métodos , Valva Mitral/cirurgia , Veias Pulmonares/cirurgia , Idoso , Fibrilação Atrial/cirurgia , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Reoperação , Resultado do Tratamento
16.
J Electrocardiol ; 48(2): 171-80, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25595719

RESUMO

BACKGROUND: Intracardiac electrograms are an indispensable part during diagnosis of supraventricular arrhythmias, but atrial activity (AA) can be obscured by ventricular far-fields (VFF). Concepts based on statistical independence like principal component analysis (PCA) cannot be applied for VFF removal during atrial tachycardia with stable conduction. METHODS: A database of realistic electrograms containing AA and VFF was generated. Both PCA and the new technique periodic component analysis (πCA) were implemented, benchmarked, and applied to clinical data. RESULTS: The concept of πCA was successfully verified to retain compromised AA morphology, showing high correlation (cc=0.98±0.01) for stable atrial cycle length (ACL). Performance of PCA failed during temporal coupling (cc=0.03±0.08) but improved for increasing conduction variability (cc=0.77±0.14). Stability of ACL was identified as a critical parameter for πCA application. Analysis of clinical data confirmed these findings. CONCLUSION: πCA is introduced as a powerful new technique for artifact removal in periodic signals. Its concept and performance were benchmarked against PCA using simulated data and demonstrated on measured electrograms.


Assuntos
Artefatos , Flutter Atrial/diagnóstico , Eletrocardiografia/métodos , Idoso , Flutter Atrial/fisiopatologia , Benchmarking , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Análise de Componente Principal , Processamento de Sinais Assistido por Computador , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/fisiopatologia
17.
Int J Cardiol Heart Vasc ; 53: 101435, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38946712

RESUMO

Background: It is currently unknown whether high-resolution 3D-mapping and micro-electrodes add meaningful benefits in catheter ablation of Wolff-Parkinson-White (WPW) syndrome and challenging, e.g. para-Hisian accessory pathways (APs). Objectives: To compare the mapping resolution, acute success and complication rates in patients with WPW syndrome undergoing a first-time catheter ablation using only a contact force-sensing ablation catheter for mapping or a multi-electrode high-resolution mapping catheter. Methods: Fifty consecutive 3D-mapping procedures for WPW syndrome using a 3.5-mm ablation catheter (n = 27) or a multi-electrode high-resolution catheter (n = 23) were retrospectively analyzed regarding mapping resolution defined as first 5/10 msec isochronal activation area, number of RF applications to achieve AP block, occurence of AP automaticity during RF delivery, and acute success and complication rates. Results: Catheter ablation was successful in 48/50 patients with a median of 1 (IQR 1-2) RF applications. Compared to ablation catheter mapping, high-resolution mapping showed a significantly smaller isochronal activation area in the first 5/10 msec (1.25 ± 0.29 vs 0.15 ± 0.03 cm2; P < 0.001 and 3.41 ± 0.58 vs 0.55 ± 0.12 cm2; P < 0.0001) and significantly higher incidence of AP automaticity during RF delivery (0 vs 22 %; P < 0.05). In para-Hisian APs, micro-electrodes recorded distinct His electrograms and AP potentials without fusion and without AP bumping permitting safe and effective para-Hisian AP ablation. Conclusions: High-resolution mapping increases the mapping accuracy of the AP and its insertion site leading to a significantly higher incidence of AP automaticity during RF delivery. Micro-electrodes provide clinically relevant advantages in para-hisian AP mapping improving efficacy and safety of para-Hisian AP ablation.

18.
Nat Med ; 30(7): 2020-2029, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38977913

RESUMO

Pulsed field ablation (PFA) is an emerging technology for the treatment of atrial fibrillation (AF), for which pre-clinical and early-stage clinical data are suggestive of some degree of preferentiality to myocardial tissue ablation without damage to adjacent structures. Here in the MANIFEST-17K study we assessed the safety of PFA by studying the post-approval use of this treatment modality. Of the 116 centers performing post-approval PFA with a pentaspline catheter, data were received from 106 centers (91.4% participation) regarding 17,642 patients undergoing PFA (mean age 64, 34.7% female, 57.8% paroxysmal AF and 35.2% persistent AF). No esophageal complications, pulmonary vein stenosis or persistent phrenic palsy was reported (transient palsy was reported in 0.06% of patients; 11 of 17,642). Major complications, reported for ~1% of patients (173 of 17,642), were pericardial tamponade (0.36%; 63 of 17,642) and vascular events (0.30%; 53 of 17,642). Stroke was rare (0.12%; 22 of 17,642) and death was even rarer (0.03%; 5 of 17,642). Unexpected complications of PFA were coronary arterial spasm in 0.14% of patients (25 of 17,642) and hemolysis-related acute renal failure necessitating hemodialysis in 0.03% of patients (5 of 17,642). Taken together, these data indicate that PFA demonstrates a favorable safety profile by avoiding much of the collateral damage seen with conventional thermal ablation. PFA has the potential to be transformative for the management of patients with AF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/terapia , Feminino , Masculino , Pessoa de Meia-Idade , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Idoso , Resultado do Tratamento , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia
19.
Europace ; 15(12): 1741-6, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23736806

RESUMO

AIMS: To provide a nationwide survey (and reference for the future) on cardiac electrophysiologists, types and numbers of invasive electrophysiological procedures, and training opportunities in 2010. METHODS AND RESULTS: German cardiology centres performing invasive electrophysiology were identified from quality reports and contacted to fill a questionnaire. A majority of 122 centres (65%) responded. Electrophysiology (ablation procedures and device therapy) was mainly part of a cardiology department (82%), and only in 9% independent (own budget). In only 58% of the centres, (at least) two physicians were present during catheter ablations. Although in 2010, women represented 59.4% of physicians <35 years old, only 26% of physicians in electrophysiology training were female. In total, 33 420 catheter ablations were performed with a median number of 180 per centre. Atrial fibrillation (AF) was the most common arrhythmia invasively treated (35%). At least 50 AF ablations were performed in 53% of the centres. Of the centres performing AF ablations, consecutive left atrial arrhythmias were treated by catheter ablation only in 75%, and only 44% had in-house surgical backup. Only one-fourth of the 122 centres fulfilled all requirements for training centre accreditation according to the European Heart Rhythm Association and the German Cardiac Society. CONCLUSION: The results indicate a high number of electrophysiology centres and procedures in Germany. Atrial fibrillation was the most common arrhythmia invasively treated. An increasing demand for catheter ablation is likely, but training opportunities are limited. Women are clearly underrepresented. A co-operation of higher and lower volume electrophysiology centres may be necessary for training purposes.


Assuntos
Arritmias Cardíacas/terapia , Serviço Hospitalar de Cardiologia/tendências , Cardiologia/tendências , Ablação por Cateter/tendências , Educação de Pós-Graduação em Medicina/tendências , Técnicas Eletrofisiológicas Cardíacas/tendências , Acreditação/tendências , Adulto , Arritmias Cardíacas/diagnóstico , Cardiologia/educação , Serviço Hospitalar de Cardiologia/estatística & dados numéricos , Ablação por Cateter/estatística & dados numéricos , Técnicas Eletrofisiológicas Cardíacas/estatística & dados numéricos , Feminino , Alemanha , Pesquisas sobre Atenção à Saúde , Hospitais com Alto Volume de Atendimentos/tendências , Hospitais com Baixo Volume de Atendimentos/tendências , Humanos , Masculino , Médicas/tendências , Avaliação de Programas e Projetos de Saúde , Inquéritos e Questionários , Fatores de Tempo , Recursos Humanos
20.
IEEE Trans Biomed Eng ; 70(2): 533-543, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-35925848

RESUMO

BACKGROUND: Electrical impedance measurements have become an accepted tool for monitoring intracardiac radio frequency ablation. Recently, the long-established generator impedance was joined by novel local impedance measurement capabilities with all electrical circuit terminals being accommodated within the catheter. OBJECTIVE: This work aims at in silico quantification of distinct influencing factors that have remained challenges due to the lack of ground truth knowledge and the superposition of effects in clinical settings. METHODS: We introduced a highly detailed in silico model of two local impedance enabled catheters, namely IntellaNav MiFi OI and IntellaNav Stablepoint, embedded in a series of clinically relevant environments. Assigning material and frequency specific conductivities and subsequently calculating the spread of the electrical field with the finite element method yielded in silico local impedances. The in silico model was validated by comparison to in vitro measurements of standardized sodium chloride solutions. We then investigated the effect of the withdrawal of the catheter into the transseptal sheath, catheter-tissue interaction, insertion of the catheter into pulmonary veins, and catheter irrigation. RESULTS: All simulated setups were in line with in vitro experiments and in human measurements and gave detailed insight into determinants of local impedance changes as well as the relation between values measured with two different devices. CONCLUSION: The in silico environment proved to be capable of resembling clinical scenarios and quantifying local impedance changes. SIGNIFICANCE: The tool can assists the interpretation of measurements in humans and has the potential to support future catheter development.


Assuntos
Ablação por Cateter , Átrios do Coração , Humanos , Impedância Elétrica , Condutividade Elétrica , Catéteres , Simulação por Computador , Ablação por Cateter/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA