Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Neth Heart J ; 32(4): 160-166, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38015347

RESUMO

BACKGROUND: Untreated atrial fibrillation (AF) often results in increased morbidity and mortality. Opportunistic AF screening in persons aged ≥ 65 years is recommended to identify patients with AF in order to prevent AF-related complications. OBJECTIVE: The aim of this study was to assess the feasibility of screening persons for AF with the Kardia mobile electrocardiogram device (MED) and to determine the percentage of newly detected AF cases by selective population screening in the Netherlands. METHODS: Persons aged ≥ 65 years, without a medical history of AF, in nursing homes, at public events or visiting the general practitioner (GP) were approached to participate. A Kardia MED smartphone ECG (sECG) was recorded and the CHA2DS2-VASc score was calculated. An automated AF algorithm classified the sECGs as 'sinus rhythm', 'AF' or 'unclassified'. In the case of AF, participants were referred to their GP. All sECGs were assessed by blinded experts. RESULTS: A total of 2168 participants were screened for AF. According to the expert's interpretation, 2.5% had newly detected AF, of whom 76.4% never experienced palpitations and 89.1% had a CHA2DS2-VASc score ≥ 2. The algorithm result was unclassified in 12.2% of cases, of which 95.5% were interpretable by experts. With expert opinion as the gold standard and excluding unclassified sECGs, the Kardia MED's negative and positive predictive value for detecting AF was 99.8% and 60.0%, respectively. CONCLUSION: Screening for AF using the Kardia MED is feasible and results in 2.5% newly detected AF cases. Expert interpretation of algorithm outcomes AF and unclassified is recommended.

2.
Europace ; 11(9): 1248-9, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19592409

RESUMO

Catheter ablation of left ventricular outflow tract tachycardia (LVOTT) holds the risk of complications, if foci are located close to the coronary artery orifices. The use of an accurate three-dimensional electro-anatomic approach is necessary to avoid ablation in the coronaries. We report a case in which we demonstrate the value of the CartoSound system, in the ablation of LVOTT.


Assuntos
Algoritmos , Ablação por Cateter/métodos , Ecocardiografia Tridimensional/instrumentação , Ecocardiografia Tridimensional/métodos , Obstrução do Fluxo Ventricular Externo/diagnóstico por imagem , Obstrução do Fluxo Ventricular Externo/cirurgia , Feminino , Humanos , Pessoa de Meia-Idade , Software , Cirurgia Assistida por Computador/métodos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA