Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Clin Med ; 13(8)2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38673445

RESUMO

(1) Objective: We aimed to assess whether the candidate profile, the long-term outcomes and the predictors for long-term mortality after transcatheter edge-to-edge mitral valve repair (M-TEER) have changed over the last decade; (2) Methods: Long-term follow-up data (median time of 1202 days) including mortality, MACCE and functional status were available for 677 consecutive patients enrolled in the prospective MiTra Ulm registry from January 2010 to April 2019. The initial 340 patients treated in our institution before January 2016 were compared with the following 337 patients; (3) Results: Patients treated after 2016 showed significantly less ventricular dilatation (left ventricular end-systolic diameter of 43 ± 13 mm vs. 49 ± 16 mm, p < 0.007), lower systolic pulmonary pressures (50 ± 15 mmHg vs. 57 ± 21 mmHg, p = 0.01) and a lower prevalence of severe tricuspid regurgitation (27.2% vs. 47.3%, p < 0.001) at baseline than patients treated before 2016. Compared to the cohort treated before 2016, patients treated afterwards showed a significantly lower all-cause 3-year mortality (29.4% vs. 43.8%, p < 0.001) and lower MACCE (38.6% vs. 54.1%, p < 0.001), without differences for MR etiology. While severe tricuspid regurgitation and NYHA class IV remained independently associated with an increased long-term mortality over the last decade, severe left ventricular dilatation (hazard ratio, HR 2.12, p = 0.047) and severe pulmonary hypertension (HR 2.18, p = 0.047) were predictors of long-term mortality only in patients treated before 2016. (4) Conclusions: The M-TEER candidates are currently treated earlier in the course of disease and benefit significantly in terms of a better long-term survival than patients treated at the beginning of the M-TEER era.

2.
Front Cardiovasc Med ; 10: 1269833, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38107259

RESUMO

Background: Conduction disturbances demanding permanent pacemaker implantation (PPI) remain a common complication after transcatheter aortic valve replacement (TAVR). Optimization of the implantation depth (ID) by introducing the cusp-overlap projection (COP) technique led to a reduced rate of PPI when self-expanding valves were used. Objectives: The aim of the present study was to determine if using the novel COP view is applicable for all types of TAVR prosthesis and results in a higher ID and reduced incidence of new conduction disturbances and PPI. Methods: In this prospective case-control study 586 consecutive patients undergoing TAVR with either balloon-expandable Edwards SAPIEN S3 (n = 280; 47.8%), or mechanically expandable Boston LOTUS Edge heart valve prostheses (n = 306; 52.2%) were included. ID as well as rates of periprocedural PPI and left bundle branch block (LBBB) were compared between the conventional three-cusp coplanar (TCC) projection and the COP view for implantation. Results: Of 586 patients, 282 (48.1%) underwent TAVR using COP, whereas in 304 patients (51.9%) the TCC view was applied. Using COP a significantly higher ID was achieved in Edwards SAPIEN S3 TAVR procedures (ID mean difference -1.0 mm, 95%-CI -1.9 to -0.1 mm; P = 0.029), whereas the final platform position did not differ significantly between both techniques when a Boston LOTUS Edge valve was used (ID mean difference -0.1 mm, 95%-CI -1.1 to +0.9 mm; P = 0.890). In Edwards SAPIEN S3 valves, higher ID was associated with a numerically lower post-procedural PPI incidence (4.9% vs. 7.3%; P = 0.464). Moreover, ID was significantly deeper in patients requiring PPI post TAVR compared to those without PPI [8.7 mm (6.8-10.6 mm) vs. 6.5 mm (6.1-7.0 mm); P = 0.005]. In Boston LOTUS Edge devices, COP view significantly decreased the incidence of LBBB post procedure (28.1% vs. 47.9%; P < 0.001), while PPI rates were similar in both groups (21.6% vs. 25.7%; P = 0.396). Conclusion: The present study demonstrates the safety, efficacy and reproducibility of the cusp-overlap view even in balloon-expandable and mechanically-expandable TAVR procedures. Application of COP leads to significantly less LBBB in repositionable Boston LOTUS Edge valves and a numerically lower PPI rate in Edwards SAPIEN S3 valves post TAVR compared to the standard TCC projection. The results should encourage to apply the COP view more widely in clinical practice.

3.
Front Cardiovasc Med ; 10: 1213992, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37671137

RESUMO

Background: Small-vessel coronary artery disease (CAD) is frequently observed in coronary angiography and linked to a higher risk of lesion failure and restenosis. Currently, treatment of small vessels is not standardized while having drug-eluting stents (DES) or drug-coated balloons (DCBs) as possible strategies. We aimed to conduct a meta-analytic approach to assess the effectiveness of treatment strategies and outcomes for small-vessel CAD. Methods: Comprehensive literature search was conducted using PubMed, Embase, MEDLINE, and Cochrane Library databases to identify studies reporting treatment strategies of small-vessel CAD with a reference diameter of ≤3.0 mm. Target lesion revascularization (TLR), target lesion thrombosis, all-cause death, myocardial infarction (MI), and major adverse cardiac events (MACE) were defined as clinical outcomes. Outcomes from single-arm and randomized studies based on measures by means of their corresponding 95% confidence intervals (CI) were compared using a meta-analytic approach. Statistical significance was assumed if CIs did not overlap. Results: Thirty-seven eligible studies with a total of 31,835 patients with small-vessel CAD were included in the present analysis. Among those, 28,147 patients were treated with DES (24 studies) and 3,299 patients with DCB (18 studies). Common baseline characteristics were equally distributed in the different studies. TLR rate was 4% in both treatment strategies [0.04; 95% CI 0.03-0.05 (DES) vs. 0.03-0.07 (DCB)]. MI occurred in 3% of patients receiving DES and in 2% treated with DCB [0.03 (0.02-0.04) vs. 0.02 (0.01-0.03)]. All-cause mortality was 3% in the DES group [0.03 (0.02-0.05)] compared with 1% in the DCB group [0.01 (0.00-0.03)]. Approximately 9% of patients with DES developed MACE vs. 4% of patients with DCB [0.09 (0.07-0.10) vs. 0.04 (0.02-0.08)]. Meta-regression analysis did not show a significant impact of reference vessel diameter on outcomes. Conclusion: This large meta-analytic approach demonstrates similar clinical and angiographic results between treatment strategies with DES and DCB in small-vessel CAD. Therefore, DES may be waived in small coronary arteries when PCI is performed with DCB.

4.
J Clin Med ; 11(2)2022 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-35054012

RESUMO

Aortic stenosis (AS) is the most frequent degenerative valvular disease in developed countries. Its incidence has been constantly rising due to population aging. The diagnosis of AS was considered straightforward for a very long time. High gradients and reduced aortic valve area were considered as "sine qua non" in diagnosis of AS until a growing body of evidence showed that patients with low gradients could also have severe AS with the same or even worse outcome. This completely changed the paradigm of AS diagnosis and involved large numbers of parameters that had never been used in the evaluation of AS severity. Low gradient AS patients may present with heart failure (HF) with preserved or reduced left ventricular ejection fraction (LVEF), associated with changes in cardiac output and flow across the aortic valve. These patients with low-flow low-gradient or paradoxical low-flow low-gradient AS are particularly challenging to diagnose, and cardiac output and flow across the aortic valve have become the most relevant parameters in evaluation of AS, besides gradients and aortic valve area. The introduction of other imaging modalities in the diagnosis of AS significantly improved our knowledge about cardiac mechanics, tissue characterization of myocardium, calcium and inflammation burden of the aortic valve, and their impact on severity, progression and prognosis of AS, not only in symptomatic but also in asymptomatic patients. However, a variety of novel parameters also brought uncertainty regarding the clinical relevance of these indices, as well as the necessity for their validation in everyday practice. The aim of this review is to summarize the prevalence of HF in patients with severe AS and elaborate on the diagnostic challenges and advantages of comprehensive multimodality cardiac imaging to identify the patients that may benefit from surgical or transcatheter aortic valve replacement, as well as parameters that may help during follow-up.

5.
Front Cardiovasc Med ; 8: 738854, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34957235

RESUMO

Background: Vascular complications after transfemoral transcatheter aortic valve implantation (TAVI) are associated with morbidity and mortality. However, consistent predictors have not been identified yet. The size of the implantation sheath seems to play a role, though especially with new generation TAVI devices and their improved sheaths and delivery systems this remains uncertain. Objectives: This study aimed to determine the incidence and predictors of access site-related vascular complications (VC) in the era of new generation TAVI devices. Methods and Results: Four hundred consecutive patients receiving TAVI in an experienced tertiary care center were analyzed. VC occurred in 89 patients (22.25%) with the majority being minor VC (21%) and only 1.25% major VC. Possible predictors for VC were tested, and only peri-interventional dual antiplatelet therapy (DAPT) showed to be predictive for VC [OR 2.11 (95% CI 1.10-4.06, p = 0.025)]. The female gender [OR 0.75 (95% CI 0.44-1.3), p = 0.31], sheath to femoral artery ratio >1.05 [OR 1.18 (95% CI 0.66-2.08, p = 0.58)], calcification of the access site vessel [OR 0.83 (95% CI 0.48-1.42, p = 0.48)], known peripheral artery disease [OR 0.95 (95% CI 0.4-2.25, p = 0.9)], and BMI ≥ 25 kg/m2 [OR 0.69 (95% CI 0.41-1.19, p = 0-19)] were not predictive of VC. The larger sheath with 20 French even showed less VC than the smaller sheath with 16 French [OR 0.43 (95% CI 0.25-0.74, p = 0.002)]. Conclusions: Overall, the rate of major and minor VC was low in this study population (for major VC: rate of 1.25%). Predefined risk factors were not associated with the occurrence of VC, except for peri-interventional treatment with DAPT. Especially, larger sheath size could not be identified as a predictor for VC in the setting of TAVI procedures performed with contemporary devices.

6.
Front Cardiovasc Med ; 8: 713625, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34527713

RESUMO

Chronic total occlusion (CTO) of coronary arteries is a common finding in patients with known or suspected coronary artery disease (CAD). Although tremendous advances have been made in the interventional treatment of CTOs over the past decade, correct patient selection remains an important parameter for achieving optimal results. Non-invasive imaging can make a valuable contribution. Ischemia and viability, two major factors in this regard, can be displayed using echocardiography, single-photon emission tomography, positron emission tomography, computed tomography, and cardiac magnetic resonance imaging. Each has its own strengths and weaknesses. Although most have been studied in patients with CAD in general, there is an increasing number of studies with positive preselectional factors for patients with CTOs. The aim of this review is to provide a structured overview of the current state of pre-interventional imaging for CTOs.

7.
J Clin Med ; 10(17)2021 Aug 24.
Artigo em Inglês | MEDLINE | ID: mdl-34501230

RESUMO

(1) Background: Long COVID syndrome refers to long-term sequelae of the novel viral disease, which occur even in patients with initially mild disease courses. However, there is still little evidence of the actual organic consequences and their frequency, and there is no standardized workup to diagnose long COVID syndrome yet. In this study, we aim to determine the efficiency of a stepwise diagnostic approach for reconvalescent COVID-19 patients with cardiopulmonary symptoms. (2) Methods: The diagnostic workup for long COVID syndrome included three steps. In the first step, the focus was on broad applicability (e.g., blood tests and body plethysmography). In the second step, cardiopulmonary exercise testing (CPET) and cardiac MRI (CMR) were used. The third step was tailored to the individual needs of each patient. The observation period lasted from 22 February to 14 May 2021. (3) Results: We examined 231 patients in our long COVID unit (mean [SD] age, 47.8 [14.9], 132 [57.1%] women). Acute illness occurred a mean (SD) of 121 (77) days previously. Suspicious findings in the first visit were seen in 80 (34.6%) patients, prompting further diagnostics. Thirty-six patients were further examined with CPET and CMR. Of those, 16 (44.4%) had pathological findings. The rest had functional complaints without organ damage ("functional long COVID"). Cardiopulmonary sequelae were found in asymptomatic as well as severe courses of the initial COVID-19 disease. (4) Conclusions: A structured diagnostic pathway for the diagnosis of long COVID syndrome is practicable and rational in terms of resource allocation. With this approach, manifest organ damage can be accurately and comprehensively diagnosed and distinguished from functional complaints.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA