Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Epilepsia ; 59(7): 1351-1361, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29893991

RESUMO

OBJECTIVE: Epilepsy is a major public health issue in low- and middle-income countries, where the availability and accessibility of quality treatment remain important issues, the severity of which may be aggravated by poor quality antiepileptic drugs (AEDs). The primary objective of this study was to measure the quality of AEDs in rural and urban areas in 3 African countries. METHODS: This cross-sectional study was carried out in Gabon, Kenya, and Madagascar. Both official and unofficial supply chains in urban and rural areas were investigated. Samples of oral AEDs were collected in areas where a patient could buy or obtain them. Pharmacological analytical procedures and Medicine Quality Assessment Reporting Guidelines were used to assess quality. RESULTS: In total, 102 batches, representing 3782 units of AEDs, were sampled. Overall, 32.3% of the tablets were of poor quality, but no significant difference was observed across sites: 26.5% in Gabon, 37.0% in Kenya, and 34.1% in Madagascar (P = .7). The highest proportions of substandard medications were found in the carbamazepine (38.7%; 95% confidence interval [CI] 21.8-57.8) and phenytoin (83.3%; 95% CI 35.8-99.5) batches, which were mainly flawed by their failure to dissolve. Sodium valproate was the AED with the poorest quality (32.1%; 95% CI 15.8-42.3). The phenobarbital (94.1%; 95% CI 80.3-99.2) and diazepam (100.0%) batches were of better quality. The prevalence of substandard quality medications increased in samples supplied by public facilities (odds ratio [OR] 9.9; 95% CI 1.2-84.1; P < .04) and manufacturers located in China (OR 119.8; 95% CI 8.7-1651.9; P < .001). The prevalence of AEDs of bad quality increased when they were stored improperly (OR 5.4; 95% CI 1.2-24.1; P < .03). SIGNIFICANCE: No counterfeiting was observed. However, inadequate AED storage conditions are likely to lead to ineffective and possibly dangerous AEDs, even when good-quality AEDs are initially imported.


Assuntos
Anticonvulsivantes/normas , Países em Desenvolvimento/estatística & dados numéricos , Controle de Qualidade , Administração Oral , Anticonvulsivantes/análise , Anticonvulsivantes/uso terapêutico , Estudos Transversais , Epilepsia/tratamento farmacológico , Gabão , Humanos , Quênia , Madagáscar , Saúde da População Rural , Saúde da População Urbana
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA