Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 80
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
N Engl J Med ; 390(21): 1959-1971, 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38587261

RESUMO

BACKGROUND: Patients with severe aortic stenosis and a small aortic annulus are at risk for impaired valvular hemodynamic performance and associated adverse cardiovascular clinical outcomes after transcatheter aortic-valve replacement (TAVR). METHODS: We randomly assigned patients with symptomatic severe aortic stenosis and an aortic-valve annulus area of 430 mm2 or less in a 1:1 ratio to undergo TAVR with either a self-expanding supraannular valve or a balloon-expandable valve. The coprimary end points, each assessed through 12 months, were a composite of death, disabling stroke, or rehospitalization for heart failure (tested for noninferiority) and a composite end point measuring bioprosthetic-valve dysfunction (tested for superiority). RESULTS: A total of 716 patients were treated at 83 sites in 13 countries (mean age, 80 years; 87% women; mean Society of Thoracic Surgeons Predicted Risk of Mortality, 3.3%). The Kaplan-Meier estimate of the percentage of patients who died, had a disabling stroke, or were rehospitalized for heart failure through 12 months was 9.4% with the self-expanding valve and 10.6% with the balloon-expandable valve (difference, -1.2 percentage points; 90% confidence interval [CI], -4.9 to 2.5; P<0.001 for noninferiority). The Kaplan-Meier estimate of the percentage of patients with bioprosthetic-valve dysfunction through 12 months was 9.4% with the self-expanding valve and 41.6% with the balloon-expandable valve (difference, -32.2 percentage points; 95% CI, -38.7 to -25.6; P<0.001 for superiority). The aortic-valve mean gradient at 12 months was 7.7 mm Hg with the self-expanding valve and 15.7 mm Hg with the balloon-expandable valve, and the corresponding values for additional secondary end points through 12 months were as follows: mean effective orifice area, 1.99 cm2 and 1.50 cm2; percentage of patients with hemodynamic structural valve dysfunction, 3.5% and 32.8%; and percentage of women with bioprosthetic-valve dysfunction, 10.2% and 43.3% (all P<0.001). Moderate or severe prosthesis-patient mismatch at 30 days was found in 11.2% of the patients in the self-expanding valve group and 35.3% of those in the balloon-expandable valve group (P<0.001). Major safety end points appeared to be similar in the two groups. CONCLUSIONS: Among patients with severe aortic stenosis and a small aortic annulus who underwent TAVR, a self-expanding supraannular valve was noninferior to a balloon-expandable valve with respect to clinical outcomes and was superior with respect to bioprosthetic-valve dysfunction through 12 months. (Funded by Medtronic; SMART ClinicalTrials.gov number, NCT04722250.).


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Bioprótese/efeitos adversos , Insuficiência Cardíaca , Estimativa de Kaplan-Meier , Complicações Pós-Operatórias/etiologia , Desenho de Prótese , Falha de Prótese , Acidente Vascular Cerebral/etiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos
2.
Lancet ; 402(10412): 1529-1540, 2023 10 28.
Artigo em Inglês | MEDLINE | ID: mdl-37660719

RESUMO

BACKGROUND: With increasing numbers of patients undergoing transcatheter aortic valve replacement (TAVR), data on management of failed TAVR, including repeat TAVR procedure, are needed. The aim of this study was to assess the safety and efficacy of redo-TAVR in a national registry. METHODS: This study included all consecutive patients in the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry from Nov 9, 2011, to Dec 30, 2022 who underwent TAVR with balloon-expandable valves in failed transcatheter heart valves (redo-TAVR) or native aortic valves (native-TAVR). Procedural, echocardiographic, and clinical outcomes were compared between redo-TAVR and native-TAVR cohorts using propensity score matching. FINDINGS: Among 350 591 patients (1320 redo-TAVR; 349 271 native-TAVR), 1320 propensity-matched pairs of patients undergoing redo-TAVR and native-TAVR were analysed (redo-TAVR cohort: mean age 78 years [SD 9]; 559 [42·3%] of 1320 female, 761 [57·7%] male; mean predicted surgical risk of 30-day mortality 8·1%). The rates of procedural complications of redo-TAVR were low (coronary compression or obstruction: four [0·3%] of 1320; intraprocedural death: eight [0·6%] of 1320; conversion to open heart surgery: six [0·5%] of 1319) and similar to native-TAVR. There was no significant difference between redo-TAVR and native-TAVR populations in death at 30 days (4·7% vs 4·0%, p=0·36) or 1 year (17·5% vs 19·0%, p=0·57), and stroke at 30 days (2·0% vs 1·9%, p=0·84) or 1 year (3·2% vs 3·5%, p=0·80). Redo-TAVR reduced aortic valve gradients at 1 year, although they were higher in the redo-TAVR group compared with the native-TAVR group (15 mm Hg vs 12 mm Hg; p<0·0001). Moderate or severe aortic regurgitation rates were similar between redo-TAVR and native-TAVR groups at 1 year (1·8% vs 3·3%, p=0·18). Death or stroke after redo-TAVR were not significantly affected by the timing of redo-TAVR (before or after 1 year of index TAVR), or by index transcatheter valve type (balloon-expandable or non-balloon-expandable). INTERPRETATION: Redo-TAVR with balloon-expandable valves effectively treated dysfunction of the index TAVR procedure with low procedural complication rates, and death and stroke rates similar to those in patients with a similar clinical profile and predicted risk undergoing TAVR for native aortic valve stenosis. Redo-TAVR with balloon-expandable valves might be a reasonable treatment for failed TAVR in selected patients. FUNDING: Edwards Lifesciences.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Feminino , Idoso , Substituição da Valva Aórtica Transcateter/métodos , Próteses Valvulares Cardíacas/efeitos adversos , Resultado do Tratamento , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Acidente Vascular Cerebral/etiologia , Sistema de Registros , Fatores de Risco , Desenho de Prótese
3.
Pacing Clin Electrophysiol ; 46(2): 195-197, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36450156

RESUMO

BACKGROUND: Patients with significant mitralregurgitation (MR) often experience atrial fibrillation (AF). The effects of transcatheter edge-to-edge repair (TEER) for MR on AF burden is unknown. METHODS: Patients who underwent TEER atthree institutions who also had a cardiac implantable electronic device with aright atrial lead were retrospectively identified. In patients with baseline AF, device data onAF burden and echocardiographic changes were recorded at baseline and 3- and 12-month follow up time points when available. Data is expressed as number (%) and median (interquartile range), withpaired values analyzed using the Wilcoxon signed-rank test. RESULTS: Overall 66 patients wereidentified, of whom 54 (82%) had baseline data on AF available for review. Of these, 18 (33%) had a baseline burden ofAF (median burden 100% [54-100%]). Patients were 77 (71-83) years old, 10 (56%) male, 14 (78%) White, and 3 (17%) Black. A significant reduction in AF burdenwas observed at 3 months (11 patients, p = 0.03) which did not retainsignificance at 12 months (8 patients, p = 0.69). Indexed maximal left atrial volumes did not significantly change inthose with paired studies available (p > 0.35 for both time points). CONCLUSIONS: In this multicenter cohort, one thirdof patients with severe MR undergoing TEER had an AF burden at baseline, whichwas found to be significantly lower at 3 month follow up. Further investigation is needed to confirm thefindings of this small cohort and determine its effects on downstream sequelaeof AF.


Assuntos
Fibrilação Atrial , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Masculino , Idoso , Idoso de 80 Anos ou mais , Feminino , Fibrilação Atrial/cirurgia , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/cirurgia , Resultado do Tratamento , Estudos Retrospectivos
4.
Am Heart J ; 243: 92-102, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34587510

RESUMO

BACKGROUND: The SMall Annuli Randomized To Evolut or SAPIEN (SMART) Trial was designed to compare the performance of the two most widely available commercial transcatheter aortic valve replacement (TAVR) devices in patients with symptomatic severe native aortic stenosis with a small aortic valve annulus undergoing transfemoral TAVR. Patients with small aortic valve annuli are typically female and are often underrepresented in clinical trials. METHODS: The SMART Trial is an international, prospective, multi-center, randomized controlled, post-market trial. The trial will be conducted in approximately 700 subjects at approximately 90 sites globally. Inclusion criteria include severe aortic stenosis, aortic valve annulus area of ≤430 mm2 based on multi-detector computed tomography, and appropriate anatomy for both the Medtronic Evolut PRO/PRO+ self-expanding and Edwards SAPIEN 3/3 Ultra balloon-expandable devices. The primary clinical outcome composite endpoint is defined as mortality, disabling stroke or heart failure rehospitalization at 12 months. The co-primary valve function composite endpoint is defined as bioprosthetic valve dysfunction at 12 months which includes hemodynamic structural valve dysfunction, defined as a mean gradient ≥20 mmHg, non-structural valve dysfunction, defined as severe prothesis-patient mismatch or ≥moderate aortic regurgitation, thrombosis, endocarditis, and aortic valve re-intervention. Powered secondary endpoints will be assessed hierarchically. CONCLUSIONS: The SMART trial will be the largest head-to-head comparative trial of transfemoral TAVR using the two most widely available contemporary TAVR devices in the setting of small aortic annuli and the largest trial to enroll primarily women. CLINICAL TRIAL REGISTRATION: URL: www.clinicaltrials.gov, Unique identifier: NCT04722250.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Feminino , Humanos , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
5.
Catheter Cardiovasc Interv ; 99(6): 1778-1783, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35347832

RESUMO

High-risk percutaneous coronary intervention (HR-PCI) is increasingly performed, often with mechanical circulatory support (MCS) provided by devices like the Impella CP. Bleeding and vascular complications remain concerns for HR-PCI, leading to significantly higher in-hospital mortality, duration of stay, and cost, which are important considerations in the decisions surrounding MCS support for HR-PCI. Newly introduced, single-catheter techniques for Impella-supported HR-PCI, along with recent approvals of dedicated large-bore closure devices (MANTA®-Vascular Closure Device) may reduce bleeding and vascular complications, but have limitations with regard to completion of peripheral angiography and/or postclosure percutaneous bailout options. The present technique offers a potential solution to these limitations, and describes a buddy microcatheter approach to postclosure management of HR-PCI with MCS, which was highly successful in a consecutive series of patients at our institution.


Assuntos
Coração Auxiliar , Intervenção Coronária Percutânea , Dispositivos de Oclusão Vascular , Angiografia , Hemorragia , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Resultado do Tratamento
6.
J Radiol Prot ; 42(4)2022 11 16.
Artigo em Inglês | MEDLINE | ID: mdl-36317283

RESUMO

Ultraviolet-C (UVC) radiation can effectively inactivate pathogens on surfaces and in the air. Due to the potential for harm to skin and eyes, human exposure to UVC should be limited within the guideline exposure limits produced by the International Commission on Non-Ionising Radiation Protection (ICNIRP) or the American Conference of Governmental Industrial Hygienists (ACGIHs). Both organisations state an effective spectrally weighted limit of 3 mJ cm-2, although the spectral weighting factors of the two organisations diverged following a revision of the ACGIH guidelines in 2022. Using existing published human exposure data, the effective spectrally weighted radiant exposure was calculated for both unfiltered and filtered (to reduce UV emissions above 230 nm) krypton chloride (KrCl*) excimer lamps. The effective radiant exposure of the filtered KrCl* lamp was greater than 3 mJ cm-2when applying ICNIRP or either of the revised ACGIH spectral weightings. This indicates that both guidelines are appropriately conservative for this specific lamp. However, the effective radiant exposure of the unfiltered KrCl* lamp was as low as 1 mJ cm-2with the revised ACGIH weighting function that can be applied to the skin if the eyes are protected. Erythema has therefore been directly observed in a clinical study at an exposure within the revised ACGIH guideline limits. Extrapolating this information means that a mild sunburn could be induced in Fitzpatrick skin types I and II if that particular ACGIH weighting function were applied and an individual received an effective exposure of 3 mJ cm-2. Whilst it is improbable that such an effect would be seen in current deployment of KrCl* lamp technology, it does highlight the need for further research into skin sensitivity and irradiance-time reciprocity for UVC wavelengths.


Assuntos
Criptônio , Exposição Ocupacional , Humanos , Cloretos , Raios Ultravioleta , Pele/efeitos da radiação , Exposição Ocupacional/análise
7.
Catheter Cardiovasc Interv ; 98(4): E637-E646, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34004077

RESUMO

OBJECTIVES: We report the 30-day outcomes from the roll-in cohort of the CLASP IID trial, representing the first procedures performed by each site. BACKGROUND: The currently enrolling CLASP IID/IIF pivotal trial is a multicenter, prospective, randomized trial assessing the safety and effectiveness of the PASCAL transcatheter valve repair system in patients with clinically significant MR. The trial allows for up to three roll-in patients per site. METHODS: Eligibility criteria were: DMR ≥3+, prohibitive surgical risk, and deemed suitable for transcatheter repair by the local heart team. Trial oversight included a central screening committee and echocardiographic core laboratory. The primary safety endpoint was a 30-day composite MAE: cardiovascular mortality, stroke, myocardial infarction (MI), new need for renal replacement therapy, severe bleeding, and non-elective mitral valve re-intervention, adjudicated by an independent clinical events committee. Thirty-day echocardiographic, functional, and quality of life outcomes were assessed. RESULTS: A total of 45 roll-in patients with mean age of 83 years and 69% in NYHA class III/IV were treated. Successful implantation was achieved in 100%. The 30-day composite MAE rate was 8.9% including one cardiovascular death (2.2%) due to severe bleeding from a hemorrhagic stroke, one MI, and no need for re-intervention. MR≤1+ was achieved in 73% and ≤2+ in 98% of patients. 89% of patients were in NYHA class I/II (p < .001) with improvements in 6MWD (30 m; p = .054) and KCCQ (17 points; p < .001). CONCLUSIONS: Early results representing sites with first experience with the PASCAL repair system showed favorable 30-day outcomes in patients with DMR≥3+ at prohibitive surgical risk.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Idoso de 80 Anos ou mais , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Estudos Prospectivos , Qualidade de Vida , Resultado do Tratamento
8.
Lasers Surg Med ; 53(5): 731-740, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33161582

RESUMO

It is possible to enhance topical drug delivery by pretreatment of the skin with ablative fractional lasers (AFLs). However, the parameters to use for a given AFL to achieve the desired depth of ablation or the desired therapeutic or cosmetic outcome are hard to predict. This leaves open the real possibility of overapplication or underapplication of laser energy to the skin. In this study, we developed a numerical model consisting of a Monte Carlo radiative transfer (MCRT) code coupled to a heat transfer and tissue damage algorithm. The simulation is designed to predict the depth effects of AFL on the skin, verified with in vitro experiments in porcine skin via optical coherence tomography (OCT) imaging. Ex vivo porcine skin is irradiated with increasing energies (50-400 mJ/pixel) from a CO2 AFL. The depth of microscopic treatment zones is measured and compared with our numerical model. The data from the OCT images and MCRT model complement each other well. Nonablative thermal effects on surrounding tissue are also discussed. This model, therefore, provides an initial step toward a predictive determination of the effects of AFL on the skin. Lasers Surg. Med. © 2020 The Authors. Lasers in Surgery and Medicine published by Wiley Periodicals LLC.


Assuntos
Terapia a Laser , Lasers de Gás , Animais , Sistemas de Liberação de Medicamentos , Lasers , Lasers de Gás/uso terapêutico , Método de Monte Carlo , Pele , Suínos , Tomografia de Coerência Óptica
10.
Ann Vasc Surg ; 46: 208-217, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28689947

RESUMO

BACKGROUND: Vascular complications remain a significant technical challenge for transfemoral TAVR (transcatheter aortic valve replacement). The goal of this study is to develop a preoperative tool for prediction of major vascular complications of TAVR. METHODS: A retrospective review was performed of all patients who underwent transfemoral TAVR at a tertiary medical center from 2011 to 2015. Iliofemoral arterial measurements were obtained with computed tomography angiography three-dimensional reconstruction images and an Iliac Morphology Score (IMS) was created from these measurements. Vascular complications were defined by Valve Academic Research Consortium (VARC-2) criteria. Statistical analyses were performed utilizing chi-squared test, Student's t-test, and binomial regression. RESULTS: We analyzed the data of 198 transfemoral TAVR patients. VARC-2 vascular complications were seen in 25 patients (13%). Major and minor vascular complication rates in the entire cohort were 4% (n = 7) and 9% (n = 18), respectively. Thirty-one patients (15.6%) required vascular surgery consultation. A total of 24 patients (12%) required surgical or percutaneous vascular interventions. Univariate analysis identified gender, iliac diameter, iliac calcification, and access type (open versus percutaneous) as predictors of major complications. The IMS was composed of ipsilateral minimum iliac diameter and iliac calcifications based on area under the receiver operator curve (AUROC) analysis (P < 0.05, AUROC = 0.82). Arterial size and calcification were classified with a value of 0-3 based on severity. Multivariate analysis identified gender and IMS as independent predictors of major complications. The mean IMS for the cohort was 3.4 (range 0-6). Patients were divided into high (IMS ≥ 5, n = 55) and low risk (IMS<5, n = 143) groups based on the inflection point for specificity (73%) and sensitivity (83%). The high-risk group had smaller iliac diameters, areas, luminal volumes, and a higher rate of major vascular complications (9% vs. 1%, P = 0.001). The 30-day mortality rate in the high score group was 9% and 1.4% in low score group (P = 0.02, AUROC = 0.72). CONCLUSIONS: An IMS composed of ipsilateral minimum iliac diameter plus iliac calcification is an excellent predictor of major vascular complications and mortality. Alternative access in patients with high IMS may reduce major vascular complications and 30-day mortality.


Assuntos
Estenose da Valva Aórtica/cirurgia , Cateterismo Periférico/efeitos adversos , Angiografia por Tomografia Computadorizada , Técnicas de Apoio para a Decisão , Artéria Femoral , Artéria Ilíaca/diagnóstico por imagem , Substituição da Valva Aórtica Transcateter/efeitos adversos , Calcificação Vascular/diagnóstico por imagem , Doenças Vasculares/etiologia , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/mortalidade , Área Sob a Curva , Cateterismo Periférico/mortalidade , Distribuição de Qui-Quadrado , Tomada de Decisão Clínica , Feminino , Humanos , Imageamento Tridimensional , Masculino , Análise Multivariada , Valor Preditivo dos Testes , Punções , Curva ROC , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Fatores Sexuais , Centros de Atenção Terciária , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento , Calcificação Vascular/complicações , Calcificação Vascular/mortalidade , Doenças Vasculares/mortalidade , Virginia
11.
Ann Surg ; 265(1): 151-157, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-28009740

RESUMO

OBJECTIVE: To determine if 5-year surgeon cumulative and annual volumes predict improved early postoperative outcomes in patients with rectal cancer. BACKGROUND: Operative experience has been shown to effect surgical outcomes. The differential role of cumulative versus annual volume has not yet been explored for rectal surgery. METHODS: The Statewide Planning and Research Cooperative System database was used to capture patients undergoing surgery in New York State from 2000 to 2013. A population-based sample of patients undergoing major rectal or rectosigmoid resection as their principal procedure during hospitalization between 2000 and 2013 were identified using International Classification of Diseases, Ninth Revision, Clinical Modification procedure codes. Surgeons were identified using a unique physician number from 1995 to 2013. RESULTS: The percentage of surgeries performed by high cumulative/high annual (HC/HA) surgeons increased from 38.3% to 58.4% (P < 0.01) with a simultaneous decrease in that performed by low cumulative/low annual (LC/LA) surgeons (52.5% to 29.8%, P < 0.01). HC/HA volume surgeons had a significantly lower rate of surgical complications (odd ratio = 0.71, 95% confidence interval = 0.60-0.83, P < 0.05) as compared with LC/LA volume surgeons. There was no significant difference in rates of anastomotic leak, nonroutine discharges or readmission among all four groups. CONCLUSIONS: The best early postoperative surgical outcomes are achieved in centers where there are high cumulative and high annual volume surgeons caring for these patients. This suggests the need for specialized designation of rectal cancer centers to support ongoing regionalization of care.


Assuntos
Competência Clínica , Hospitais com Alto Volume de Atendimentos , Complicações Pós-Operatórias/etiologia , Neoplasias Retais/cirurgia , Cirurgiões/estatística & dados numéricos , Adulto , Idoso , Idoso de 80 Anos ou mais , Bases de Dados Factuais , Feminino , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , New York , Avaliação de Resultados em Cuidados de Saúde , Readmissão do Paciente/estatística & dados numéricos , Complicações Pós-Operatórias/epidemiologia
12.
Vet Ophthalmol ; 20(5): 411-419, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27862797

RESUMO

OBJECTIVE: To (i) correlate B-mode ocular ultrasound (US) and computed tomography (CT) (prospective pilot study), (ii) establish a reliable method to measure the normal canine eye using CT, (iii) establish a reference guide for some dog breeds, (iv) compare eye size between different breeds and breed groups, and (v) investigate the correlation between eye dimensions and body weight, gender, and skull type (retrospective study). PROCEDURE: B-mode US and CT were performed on ten sheep cadaveric eyes. CT biometry involved 100 adult pure-bred dogs with nonocular and nonorbital disease, representing eleven breeds. Eye length, width, and height were each measured in two of three planes (horizontal, sagittal, and equatorial). RESULTS: B-mode US and CT measurements of sheep cadaveric eyes correlated well (0.70-0.71). The shape of the canine eye was found to be akin to an oblate spheroid (a flattened sphere). A reference guide was established for eleven breeds. Eyes of large breed dogs were significantly larger than those of medium and small breed dogs (P < 0.01), and eyes of medium breed dogs were significantly larger than those of small breed dogs (P < 0.01). Eye size correlated with body weight (0.74-0.82) but not gender or skull type. CONCLUSIONS: Computed tomography is a suitable method for biometry of the canine eye, and a reference guide was established for eleven breeds. Eye size correlated with breed size and body weight. Because correlation between B-mode US and CT was shown, the obtained values can be applied in the clinical setting, for example, for the diagnosis of microphthalmos and buphthalmos.


Assuntos
Olho/diagnóstico por imagem , Animais , Biometria , Peso Corporal , Cães , Olho/anatomia & histologia , Tamanho do Órgão , Projetos Piloto , Estudos Prospectivos , Padrões de Referência , Estudos Retrospectivos , Ovinos , Especificidade da Espécie , Tomografia Computadorizada por Raios X/veterinária , Ultrassonografia/veterinária
13.
Dis Colon Rectum ; 59(1): 16-21, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26651107

RESUMO

BACKGROUND: Benign colon polyps are commonly encountered but may not always be amenable to endoscopic excision because of their size, shape, location, or scarring from previous attempts. The addition of laparoscopy allows a greater degree of bowel manipulation, but the current technique is still limited when encountering a polyp with inadequate lifting attributed to polyp morphology or scarring. We describe an extension to the existing combined endoscopic laparoscopic surgery technique using a full-thickness approach to increase polyp maneuverability and local excision of difficult but benign polyps. OBJECTIVE: The purpose of this study was to report the technical details and preliminary results of a new approach for full-thickness excision of difficult colon polyps, combined endoscopic laparoscopic surgery full-thickness excision. DESIGN: This study is a retrospective review of our experience from December 2013 to May 2015. SETTINGS: The study was conducted at a single academic institution. PATIENTS: All of the patients had previous incomplete colonoscopic polypectomy performed at other institutions. Patients were selected for our technique if the polyp had a benign appearance but was unable to be resected by traditional endoscopic or combined endoscopic laparoscopic surgery methods because of polyp morphology or scarring from previous biopsies. MAIN OUTCOME MEASURES: The safety and feasibility of this procedure were measured. RESULTS: Three patients underwent combined endoscopic laparoscopic surgery-full-thickness excision for difficult colon polyps. There were no intraoperative or postoperative complications. The length of stay was 1 day for all of the patients. All 3 of the patients had benign final pathology. LIMITATIONS: This study was limited by the small number of patients in a single institution. CONCLUSIONS: Full-thickness excision for benign colon polyps using combined endoscopic laparoscopic surgery is safe and feasible. Using this technique, difficult polyps not amenable to traditional endoscopic approaches can be removed and colectomy may be avoided.

14.
J Surg Res ; 205(1): 11-8, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-27620993

RESUMO

BACKGROUND: As the population ages, an increasing number of older patients are undergoing major surgery. We examined the impact of advanced age on outcomes following major gastrointestinal cancer surgery in an era of improved surgical outcomes. MATERIALS AND METHODS: This was a population-based, retrospective cohort study using the American College of Surgeons National Surgical Quality Improvement Program database. We evaluated patients undergoing major abdominal gastrointestinal cancer surgery from 2005-2012. Multivariable logistic regression was performed to determine the independent effect of advanced age on outcomes. Our primary outcome was 30-d mortality, and our secondary outcomes were 30-d major postoperative adverse events, discharge disposition, length of stay, reoperation, and readmission. RESULTS: Elderly (≥65 y) patients were twice as likely to have multiple comorbidities as those <65 y but prevalence of comorbidities was similar across all older age groups. Mortality increased with age across all procedures (P < 0.05). The risk of advanced age on mortality was highest in hepatectomy (odds ratio = 5.17, 95% confidence interval = 2.19-12.20) and that for major postoperative adverse events was highest in proctectomy (odds ratio = 2.32, 95% confidence interval = 1.53-3.52). Patients were more likely to be discharged to an institutional care facility as age increased across all procedures (P < 0.01). CONCLUSIONS: Despite being highly selected for surgery, elderly patients undergoing major gastrointestinal cancer surgery have substantially worse postoperative outcomes than younger patients (<65 y). The risk of age on postoperative outcomes was present across all operations but had its highest association with liver and rectal cancer resections.


Assuntos
Envelhecimento , Procedimentos Cirúrgicos do Sistema Digestório/mortalidade , Neoplasias Gastrointestinais/cirurgia , Complicações Pós-Operatórias/epidemiologia , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Estados Unidos/epidemiologia
16.
Surg Innov ; 23(4): 337-40, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27076573

RESUMO

Recent evidence suggests surgical quality may be demonstrated and evaluated using video capture during surgery. Operative video documentation may also aid in quality improvement initiatives. We discuss how operative video has the potential to help improve patient outcomes and increase professional accountability, patient safety, and surgical quality.


Assuntos
Melhoria de Qualidade , Procedimentos Cirúrgicos Operatórios , Gravação em Vídeo , Humanos
17.
Int J Colorectal Dis ; 30(1): 11-8, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25354968

RESUMO

PURPOSE: Cancers developing near the site of the ileoanal pouch anastomosis (IPAA) have been reported, but uncommonly in the ileal pouch mucosa itself. We present a recently encountered case of ileal pouch cancer and review the literature to examine the prevalence, risk factors, and natural history of ileal pouch adenocarcinoma as well as pouch surveillance. METHODS: A chart review of the case from our institution was conducted, and a PubMed search was undertaken for articles describing adenocarcinoma arising from the ileal pouch mucosa. RESULTS: Twenty articles containing 26 cases were reviewed in addition to our described case. More than half were reported in the last decade. Only three cases were definitively stage 1. All seven patients who underwent regular surveillance were diagnosed with stage 1 or 2 disease. Seventeen patients had neoplasia in their original proctocolectomy specimen and six did not. The mean time from pouch creation to adenocarcinoma was 8.9 years. CONCLUSIONS: The risk of developing ileal pouch mucosa adenocarcinoma appears low. However, increasing reports of these cancers are concerning as most patients present with advanced disease after many years. Patients with a previous history of dysplasia/cancer may be at increased risk. We believe surveillance after IPAA should include the anal transition zone and the ileal pouch mucosa. The establishment of expert consensus guidelines on pouch surveillance should be considered in the near future.


Assuntos
Adenocarcinoma/diagnóstico , Bolsas Cólicas , Neoplasias do Íleo/diagnóstico , Mucosa Intestinal/patologia , Adenocarcinoma/complicações , Adenocarcinoma/cirurgia , Adulto , Idoso , Colite Ulcerativa/cirurgia , Bolsas Cólicas/efeitos adversos , Feminino , Humanos , Neoplasias do Íleo/complicações , Neoplasias do Íleo/cirurgia , Mucosa Intestinal/cirurgia , Masculino , Pessoa de Meia-Idade , Pouchite/complicações , Pouchite/etiologia , Proctocolectomia Restauradora/efeitos adversos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
18.
Photochem Photobiol ; 100(1): 137-145, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37029739

RESUMO

Far-UVC, from filtered Krypton-Chloride lamps, is promising for reducing airborne transmission of disease. While significant research has been undertaken to investigate skin safety of these lamps, less work has been undertaken on eye safety. There is limited data on human eye safety or discomfort from the deployment of this germicidal technology. In this pilot study, immediate and delayed eye discomfort were assessed in a simulated office environment with deployment of Krypton-Chloride lamps, located on the ceiling and directed downwards into the occupied room. Discomfort was assessed immediately postexposure and several days after exposure using validated, Standard Patient Evaluation Eye Dryness (SPEED) and Ocular Surface Disease Index (OSDI) questionnaires. Our results show no significant eye discomfort or adverse effects from the deployment of Far-UVC in this simulated office environment, even when lamps were operated continuously with participants receiving head exposures of up to 50 mJ cm-2 . In addition, a statistically significant reduction in bacteria and fungi of 52% was observed. Far-UVC in this simulated office environment did not cause any clinically significant eye discomfort and was effective at reducing pathogens in the room. These results contribute an important step to further investigation of the interaction of Far-UVC with the human eye.


Assuntos
Cloretos , Raios Ultravioleta , Humanos , Criptônio , Projetos Piloto , Pele/microbiologia , Desinfecção/métodos
19.
Eur J Heart Fail ; 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38726573

RESUMO

AIM: This analysis aimed to compare the clinical outcomes associated with heart failure (HF) readmissions and to identify associations with HF hospitalizations (HFH) in patients treated with the MitraClip™ NTR/XTR System in the EXPAND study. METHODS AND RESULTS: The global, real-world EXPAND study enrolled 1041 patients with primary or secondary mitral regurgitation (MR) treated with the MitraClip NTR/XTR System. Echocardiograms were analysed by an independent echocardiographic core laboratory. The study population was stratified into HFH and No-HFH groups based on the occurrence of HFH 1 year post-index procedure. Clinical outcomes including MR severity, New York Heart Association (NYHA) functional class, Kansas City Cardiomyopathy Questionnaire (KCCQ) score, and all-cause mortality were compared (HFH: n = 181; No-HFH: n = 860). Both groups achieved consistent 1-year MR reduction to ≤1+ (HFH vs. No-HFH: 87.3% vs. 89.5%, p = 0.6) and significant 1-year improvement in KCCQ scores (+16.5 vs. +22.3, p = 0.09) and NYHA functional class. However, more patients in the No-HFH group had 1-year NYHA class ≤II (HFH vs. No-HFH: 67.9% vs. 81.9%, p < 0.01). All-cause mortality at 1 year was 36.8% in the HFH group versus 10.4% in the No-HFH group (p < 0.001). The HFH rate decreased by 63% at 1 year post-M-TEER versus 1 year pre-treatment (relative risk 0.4, p < 0.001). Independent HFH associations were MR ≥2+ at discharge, HFH 1 year prior to treatment, baseline NYHA class ≥III, baseline tricuspid regurgitation ≥2+, and baseline left ventricular ejection fraction ≤40%. CONCLUSIONS: This study reports the impact of HFH on clinical outcomes post-treatment in the EXPAND study. Results demonstrate that the occurrence of HFH was associated with worse 1-year survival, and treatment with the MitraClip system substantially reduced HFH and improved patient symptoms and quality of life.

20.
Artigo em Inglês | MEDLINE | ID: mdl-38871537

RESUMO

BACKGROUND: Permanent pacemaker implantation (PPI) rates following transcatheter aortic valve replacement (TAVR) remain a concern. We assessed the PPI rates over time in patients implanted with an Evolut supra-annular, self-expanding transcatheter valve from the US STS/ACC TVT Registry. METHODS: Patients who underwent TAVR with an Evolut R, Evolut PRO or Evolut PRO+ valve between July 2018 (Q3) and June 2021 (Q2) were included. PPI rates were reported by calendar quarter. In-hospital PPI rates were reported as proportions and 30-day rates as Kaplan-Meier estimates. A Cox regression model was used to determine potential predictors of a new PPI within 30 days of the TAVR procedure. RESULTS: From July 2018 to June 2021, 54,014 TAVR procedures were performed using Evolut valves. Mean age was 79.3 ± 8.8 years and 49.2 % were male. The 30-day PPI rate was 16.6 % in 2018 (Q3) and 10.8 % in 2021 (Q2, 34.9 % decrease, p < 0.001 for trend across all quarters). The in-hospital PPI rate decreased by 40.1 %; from 14.7 % in 2018 (Q3) to 8.8 % in 2021 (Q2) (p < 0.001 for trend across all quarters). Significant predictors of a new PPI within 30 days included a baseline conduction defect, history of atrial fibrillation, home oxygen, and diabetes mellitus. CONCLUSION: From 2018 to 2021, TAVR with an Evolut transcatheter heart valve in over 50,000 patients showed a significant decreasing trend in the rates of in-hospital and 30-day PPI, representing the lowest rate of PPI in any large real-world registry of Evolut. During the same evaluated period, high device success and shorter length of stay was also observed.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA