Clin Chem ; 57(12): 1739-47, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21998339

RESUMO

BACKGROUND: Owing to the lack of an internationally recognized tacrolimus reference material and reference method, current LC-MS and immunoassay test methods used to monitor tacrolimus concentrations in whole blood are not standardized. The aim of this study was to assess the need for tacrolimus assay standardization. METHODS: We sent a blinded 40-member whole-blood tacrolimus proficiency panel (0-30 µg/L) to 22 clinical laboratories in 14 countries to be tested by the following assays: Abbott ARCHITECT (n = 17), LC-MS (n = 9), and Siemens Dade Dimension (n = 5). Selected LC-MS laboratories (n = 4) also received a common calibrator set. We compared test results to a validated LC-MS method. Four samples from the proficiency panel were assigned reference values by using exact-matching isotope-dilution mass spectrometr at LGC. RESULTS: The range of CVs observed with the tacrolimus proficiency panel was as follows: LC-MS 11.4%-18.7%, ARCHITECT 3.9%-9.5%, and Siemens Dade 5.0%-48.1%. The range of historical within-site QC CVs obtained with the use of 3 control concentrations were as follows: LC-MS low 3.8%-10.7%, medium 2.0%-9.3%, high 2.3%-9.0%; ARCHITECT low 2.5%-9.5%, medium 2.5%-8.6%, high 2.9%-18.6%; and Siemens/Dade Dimension low 8.7%-23.0%, medium 7.6%-13.2%, high 4.4%-10.4%. Assay bias observed between the 4 LC-MS sites was not corrected by implementation of a common calibrator set. CONCLUSIONS: Tacrolimus assay standardization will be necessary to compare patient results between clinical laboratories. Improved assay accuracy is required to provide optimized drug dosing and consistent care across transplant centers globally.


Assuntos
Imunossupressores/sangue , Tacrolimo/sangue , Cromatografia Líquida , Humanos , Imunoensaio/normas , Imunossupressores/normas , Cooperação Internacional , Ensaio de Proficiência Laboratorial , Padrões de Referência , Tacrolimo/normas , Espectrometria de Massas em Tandem
2.
Ther Drug Monit ; 32(2): 145-51, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20216110

RESUMO

The objective of this study was to evaluate the analytical performance of the Abbott ARCHITECT Cyclosporine (CsA) immunoassay in 7 clinical laboratories in comparison to liquid chromatography/tandem mass spectrometry (LC/MS/MS), Abbott TDx, Cobas Integra 800, and the Dade Dimension Xpand immunoassay. The ARCHITECT assay uses a whole blood specimen, a pretreatment step with organic reagents to precipitate proteins and extract the drug, followed by a 2-step automated immunoassay with magnetic microparticles coated with anti-CsA antibody and an acridinium-CsA tracer. Imprecision testing at the 7 evaluation sites gave a range of total % coefficient of variations of 7.5%-12.2% at 87.5 ng/mL, 6.6%-14.3% at 411 ng/mL, and 5.2%-10.7% at 916 ng/mL. The lower limit of quantification ranged from 12 to 20 ng/mL. Purified CsA metabolites AM1, AM1c, AM4N, AM9, and AM19 were tested in whole blood by the ARCHITECT assay and showed minimal cross-reactivity at all 7 sites. In particular, AM1 and AM9 cross-reactivity in the ARCHITECT assay, ranged from -2.5% to 0.2% and -0.8% to 2.2%, respectively, and was significantly lower than for the TDx assay, in which the values were 3.2% and 16.1%, respectively. Comparable testing of metabolites in the Dade Dimension Xpand assay at 2 evaluation sites showed cross-reactivity to AM4N (6.4% and 6.8%) and AM9 (2.6% and 3.6%) and testing on the Roche Integra 800 showed cross-reactivity to AM1c (2.4%), AM9 (10.7%), and AM19 (2.8%). Cyclosporine International Proficiency Testing Scheme samples, consisting of both pooled specimens from patients receiving CsA therapy as well as whole-blood specimens supplemented with CsA, were tested by the ARCHITECT assay at 6 sites and showed an average bias of -24 to -58 ng/mL versus LC/MSMS CsA and -2 to -37 ng/mL versus AxSYM CsA. Studies were performed with the ARCHITECT CsA assay on patient specimens with the following results: ARCHITECT CsA assay versus LC/MSMS, average bias of 31 ng/mL; ARCHITECT versus the Dade Dimension assay (4 sites), average biases of -7 to -228 ng/mL; ARCHITECT versus AxSYM and TDx, average biases of -4 and -53 ng/mL, respectively. Spearman correlation coefficients were >or=0.89. The ARCHITECT CsA assay has significantly reduced CsA metabolite interference relative to other immunoassays and is a convenient and sensitive semiautomated method to measure CsA in whole blood.


Assuntos
Técnicas de Química Analítica/métodos , Técnicas de Química Analítica/normas , Ciclosporina/sangue , Especificidade de Anticorpos , Avaliação Pré-Clínica de Medicamentos/métodos , Avaliação Pré-Clínica de Medicamentos/normas , Humanos , Imunoensaio/métodos , Imunoensaio/normas
3.
J Clin Microbiol ; 47(3): 603-13, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19129411

RESUMO

Determination of the avidity of immunoglobulin G (IgG) directed against a specific marker has become an established diagnostic tool for identifying or excluding acute infections with pathogens. A novel assay format termed AVIcomp (avidity competition based on mass action) circumventing the conventional chaotropic format has been developed for determination of the avidity of marker-specific IgG in patient specimens. Its applications for cytomegalovirus (CMV) and Toxoplasma gondii are presented. Specific high-avidity IgG from the patient specimen is selectively blocked using a soluble antigen in a sample pretreatment reagent, and the amount of remaining specific low-avidity IgG is determined relative to that in an untreated control. The comparison of the conventional chaotropic format, represented by the Radim CMV IgG Avidity assay, and the newly developed AVIcomp method, as exemplified by the Architect CMV IgG Avidity assay, on blood drawn within 4 months after seroconversion revealed a sensitivity of 100% (97.3% by an alternative calculation) for the AVIcomp format versus 87.5% (75.7% by an alternative calculation) for the chaotropic avidity assay. The specificity on 312 CMV IgG reactive and CMV IgM nonreactive specimens from pregnant women was 100% for the AVIcomp assay and 99.7% for the conventional avidity assay. The Architect Toxo IgG Avidity assay showed an agreement of 97.2% with the bioMérieux Vidas Toxo IgG Avidity Assay employing chaotropic reagents. These performance data suggest that the AVIcomp format shows superior sensitivity and equivalent specificity for the determination of IgG avidity to assays based on the chaotropic method and that the AVIcomp format may also be applicable to other disease states.


Assuntos
Anticorpos Antiprotozoários/imunologia , Anticorpos Antivirais/imunologia , Afinidade de Anticorpos , Infecções por Citomegalovirus/diagnóstico , Imunoglobulina G/imunologia , Toxoplasmose/diagnóstico , Animais , Automação , Citomegalovirus/imunologia , Infecções por Citomegalovirus/imunologia , Humanos , Imunoglobulina M/imunologia , Sensibilidade e Especificidade , Toxoplasma/imunologia , Toxoplasmose/imunologia
4.
Transfusion ; 49(1): 134-45, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18954407

RESUMO

BACKGROUND: Cytomegalovirus (CMV) antibody donor screening assays have predominantly included both immunoglobulin G (IgG) and immunoglobulin M (IgM) detection. However, since in the majority of cases both CMV IgG and IgM are detected concomitantly during early seroconversion, CMV assays based only on IgG are now widely applied for donor screening. STUDY DESIGN AND METHODS: The performance of an automated microparticle CMV IgG assay (Abbott AxSYM CMV IgG microparticle enzyme immunoassay [MEIA]) was compared with an established total antibody blood screening assay (Abbott CMV Total AB EIA). Sensitivity and specificity were assessed using 5050 random blood donors and 13 seroconversion panels. A risk analysis was undertaken to estimate the residual risk of transfusion-transmitted CMV (TT-CMV) from presumptive seronegative blood components. RESULTS: The EIA achieved marginally (but not significantly) better resolved sensitivity (100%) than the AxSYM IgG assay (99.93%). The AxSYM IgG resolved specificity (99.34%) was superior to the EIA (96.4%). This superiority was maintained (98.61%) when a modified cutoff was applied to the AxSYM IgG assay to achieve 100 percent resolved sensitivity. The seroconversion sensitivities of the EIA and the AxSYM IgG were equivalent, detecting the same bleed as positive in the majority of the seroconversion panels tested. The median TT-CMV residual risk estimate for the two assays was approximately 1 in 66,000 (range, 42,000-165,000). CONCLUSION: The AxSYM IgG MEIA is suitable for blood donor screening and was optimized by applying a modified cutoff of 9 AU per mL. The modeling predicts that implementing the AxSYM IgG assay would not negatively impact the already very low risk of TT-CMV associated with seronegative blood components in Australia.


Assuntos
Anticorpos Antivirais/imunologia , Doadores de Sangue , Infecções por Citomegalovirus/imunologia , Infecções por Citomegalovirus/transmissão , Citomegalovirus/imunologia , Seleção do Doador/métodos , Imunoglobulina G/imunologia , Modelos Biológicos , Anticorpos Antivirais/sangue , Infecções por Citomegalovirus/sangue , Humanos , Técnicas Imunoenzimáticas/instrumentação , Técnicas Imunoenzimáticas/métodos , Imunoglobulina G/sangue , Imunoglobulina M/sangue , Imunoglobulina M/imunologia , Fatores de Risco
5.
Ther Drug Monit ; 31(2): 198-204, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19258928

RESUMO

The objective of this study was to evaluate the analytical performance of the Abbott ARCHITECT Tacrolimus immunoassay. Proficiency panels and specimens from a population of organ transplant recipients were analyzed in 6 clinical laboratories in Europe and the United States, and the results were compared with other methods. The ARCHITECT assay requires a whole blood specimen pretreatment step with methanol/zinc sulfate to precipitate protein and extract the drug, followed by a 30-minute immunoassay using anti-tacrolimus antibody-coated paramagnetic microparticles and an acridinium-tacrolimus tracer. The assay was free from hematocrit interference in the range 25%-55% and from interference by extremes of cholesterol, triglycerides, bilirubin, total protein, and uric acid. The total percent of coefficient of variations of the assay were 4.9%-7.6% at 3 ng/mL, 2.9%-4.6% at 8.6 ng/mL, and 3.1%-8.2% at 15.5 ng/mL. Limit of detection was < or =0.5 ng/mL and limit of quantification (LOQ) ranged from 0.69 to 1.07 ng/mL across the 6 sites (based on the upper 95% confidence interval concentrations). The 2007 European Consensus Conference on Tacrolimus Optimization recommended the use of assay methods with an LOQ around 1 ng/mL, based upon the need to measure trough tacrolimus blood concentrations precisely down to 3 ng/mL during low-dose tacrolimus regimens. Tacrolimus International Proficiency Testing Scheme samples were measured by the ARCHITECT immunoassay at 5 sites and showed an average bias of -0.28 to +0.85 ng/mL versus IMx Tacrolimus II immunoassay historical values and -0.21 to +0.68 ng/mL versus liquid chromatography/tandem mass spectrometry (LC-MSMS) Tacrolimus historical values. Method comparison studies were performed with the ARCHITECT Tacrolimus immunoassay on patient specimens with the following results: ARCHITECT Tacrolimus assay versus the Abbott IMx Tacrolimus II immunoassay (4 sites) yielded average biases between -0.94 and +0.26 ng/mL; ARCHITECT assay versus the Dade Dimension Tacrolimus immunoassay (2 sites) yielded average biases of -0.46 and +0.11 ng/mL; and ARCHITECT assay versus LC-MSMS methods at 2 sites yielded average biases of +0.51 and +1.63 ng/mL. Spearman correlation coefficients were >/=0.90 on all method comparisons. The ARCHITECT Tacrolimus assay is a semiautomated, robust, and highly sensitive immunoassay, representing an alternative approach for laboratories not equipped with LC-MSMS, and meets the 1 ng/mL recommendation of LOQ by the European Consensus Conference on Tacrolimus Optimization.


Assuntos
Imunossupressores/sangue , Tacrolimo/sangue , Cromatografia Líquida , Humanos , Imunoensaio , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem
6.
Diagn Microbiol Infect Dis ; 73(3): 275-7, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22541330

RESUMO

Retrospective evaluation of the kinetics of cytomegalovirus (CMV) seroconversion with CMV IgM, IgG, and IgG avidity assays, in a Swiss pregnant women population, has shown that the current published CMV serologic diagnostic algorithms were valid and fit for use. In 19% of the cases analyzed, CMV-specific IgM was detected before IgG.


Assuntos
Anticorpos Antivirais/sangue , Infecções por Citomegalovirus/diagnóstico , Infecções por Citomegalovirus/imunologia , Citomegalovirus/imunologia , Complicações Infecciosas na Gravidez/diagnóstico , Complicações Infecciosas na Gravidez/imunologia , Adulto , Afinidade de Anticorpos , Feminino , Humanos , Imunoglobulina G/sangue , Imunoglobulina M/sangue , Gravidez , Estudos Retrospectivos , Suíça
7.
Clin Biochem ; 42(15): 1543-8, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19563794

RESUMO

OBJECTIVE: This study evaluated a new chemiluminescent magnetic microparticle immunoassay (CMIA) for sirolimus on the ARCHITECT analyzer. DESIGN AND METHODS: Patient and laboratory proficiency samples were tested at three European sites and one site in the United States. RESULTS: The CMIA total %CV's were all <8% and the Limit of Quantification (LOQ) was <1.52 ng/mL across the four sites. It cross-reacts to sirolimus metabolites F4 and F5 and showed no hematocrit interference over a range of 25% to 55%. Patient specimen correlations to three LC/MS/MS methods gave R>or=0.91 at three sites and mean biases of 14%, 25% and 39%. CMIA patient specimen correlations to the Abbott IMx gave R>or=0.94 at 2 sites and mean biases of 5.4% and 6.9%. CONCLUSIONS: CMIA is a precise and sensitive immunoassay method without hematocrit interference. It correlates well to both LC/MS/MS and immunoassay results, but shows an expected positive bias to LC/MS/MS.


Assuntos
Imunoensaio/métodos , Imunossupressores/sangue , Medições Luminescentes/métodos , Magnetismo , Sirolimo/sangue , Especificidade de Anticorpos , Cromatografia Líquida/métodos , Humanos , Imunoensaio/instrumentação , Medições Luminescentes/instrumentação , Tamanho da Partícula , Sensibilidade e Especificidade , Espectrometria de Massas em Tandem/métodos