Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 45
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Vasc Interv Radiol ; : 1576-1583.e7, 2023 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-37201657

RESUMO

PURPOSE: To assess the completeness of reporting in abstracts of published randomized controlled trials (RCTs) assessing interventional radiology (IR) for liver disease; to assess whether publication of the 2017 CONSORT update for nonpharmacological treatments (NPT) resulted in changes in abstract reporting; and to identify factors associated with better reporting. MATERIAL AND METHODS: MEDLINE and Embase were searched to identify RCTs of IR for liver disease (January 2015-September 2020). Two reviewers assessed the completeness of abstract reporting according to the CONSORT-NPT-2017-update. The primary outcome was the mean number of CONSORT items completely reported among 10 items reported in <50% of the abstracts published in 2015. A time series analysis assessed the evolution trend over time. A multivariate regression model was used to identify factors associated with better reporting. RESULTS: A total of 107 abstracts of RCTs published in 61 journals were included. Overall, 74% (45/61) of journals endorsed the main CONSORT guidelines, of which 60% (27/45) had a policy to implement them. The mean number of primary outcome items completely reported increased by 0.19 over the study period. The publication of the CONSORT-NPT update did not lead to an increase in the trend of items reported (increase of 0.04 items/month before vs. 0.02 after, P=0.41). Factors associated with more complete reporting were impact factor (OR=1.13; 95%CI:1.07-1.18) and endorsement of CONSORT with an implementation policy (OR=8.29; 95%CI:2.04-33.65). CONCLUSION: Completeness of reporting is incomplete in abstracts of trials of IR liver disease and did not improve after publication of the CONSORT-NPT-2017 update with abstract guidance.

2.
Br J Surg ; 109(5): 455-463, 2022 04 19.
Artigo em Inglês | MEDLINE | ID: mdl-35141742

RESUMO

BACKGROUND: Posthepatectomy liver failure (PHLF) is a rare but dreaded complication. The aim was to test whether a combination of non-invasive biomarkers (NIBs) and CT data could predict the risk of PHLF in patients who underwent resection of hepatocellular carcinoma (HCC). METHODS: Patients with HCC who had liver resection between 2012 and 2020 were included. A relevant combination of NIBs (NIB model) to model PHLF risk was identified using a doubly robust estimator (inverse probability weighting combined with logistic regression). The adjustment variables were body surface area, ASA fitness grade, male sex, future liver remnant (FLR) ratio, difficulty of liver resection, and blood loss. The reference invasive biomarker (IB) model comprised a combination of pathological analysis of the underlying liver and hepatic venous pressure gradient (HVPG) measurement. Various NIB and IB models for prediction of PHLF were fitted and compared. NIB model performances were validated externally. Areas under the curve (AUCs) were corrected using bootstrapping. RESULTS: Overall 323 patients were included. The doubly robust estimator showed that hepatitis C infection (odds ratio (OR) 4.33, 95 per cent c.i. 1.29 to 9.20; P = 0.001), MELD score (OR 1.26, 1.04 to 1.66; P = 0.001), fibrosis-4 score (OR 1.36, 1.06 to 1.85; P = 0.001), liver surface nodularity score (OR 1.55, 1.28 to 4.29; P = 0.031), and FLR volume ratio (OR 0.99, 0.97 to 1.00; P = 0.014) were associated with PHLF. Their combination (NIB model) was fitted externally (2-centre cohort, 165 patients) to model PHLF risk (AUC 0.867). Among 129 of 323 patients who underwent preoperative HVPG measurement, NIB and IB models had similar performances (AUC 0.753 versus 0.732; P = 0.940). A well calibrated nomogram was drawn based on the NIB model (AUC 0.740). The risk of grade B/C PHLF could be ruled out in patients with a cumulative score of less than 160 points. CONCLUSION: The NIB model provides reliable preoperative evaluation with performance at least similar to that of invasive methods for PHLF risk prediction.


Assuntos
Carcinoma Hepatocelular , Falência Hepática , Neoplasias Hepáticas , Biomarcadores , Carcinoma Hepatocelular/patologia , Carcinoma Hepatocelular/cirurgia , Hepatectomia/efeitos adversos , Humanos , Falência Hepática/diagnóstico , Falência Hepática/etiologia , Neoplasias Hepáticas/patologia , Masculino , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/cirurgia , Estudos Retrospectivos
3.
Ann Hematol ; 100(5): 1241-1249, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33660034

RESUMO

The objective of this study is to evaluate the prognostic features of multiple myeloma (MM) using whole-body low-dose computed tomography (WBLDCT). One hundred three patients with biopsy-proven MM who underwent WBLDCT were retrospectively enrolled. The evolution of osteolytic lesions overtime was performed by measuring the maximum axial diameter at the baseline (T0) and the end of follow-up (Te), by using a cut-off value of 10 mm. The location and dimension of up to three lesions were registered. The time-to-fracture (TTF) was recorded. Sixty-three percent of patients presented a focal pattern, 22% a diffuse pattern, and 15% a combined one. Seventy-two percent of patients with lesions ≤ 10 mm presented stability, 27% a dimensional increase, and 1% a decrease. Patients with lesions >10 mm showed a statistically significant difference regarding the mean difference of axial diameter between T0 and Te (p = 0.015). Patients with lesions >10 mm showed an odds ratio (OR) of 29.8 (95%CIs 3.8-230.5) to develop at least one fracture. Mean TTF was significantly lower in patients with lesions >10 mm in comparison with lesions ≤ 10 mm (9 ± 3 vs 23 ± 7 months, respectively, p = 0.011). WBLDCT represents a reliable imaging-based tool for proper management of MM patients, showing that diffuse form or small lytic lesions may deserve a less frequent follow-up.


Assuntos
Mieloma Múltiplo/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Mieloma Múltiplo/patologia , Estadiamento de Neoplasias/métodos , Doses de Radiação , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Imagem Corporal Total/métodos
4.
Eur Radiol ; 31(5): 2726-2736, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33125559

RESUMO

OBJECTIVES: To evaluate a semi-automated segmentation and ventilated lung quantification on chest computed tomography (CT) to assess lung involvement in patients affected by SARS-CoV-2. Results were compared with clinical and functional parameters and outcomes. METHODS: All images underwent quantitative analyses with a dedicated workstation using a semi-automatic lung segmentation software to compute ventilated lung volume (VLV), Ground-glass opacity (GGO) volume (GGO-V), and consolidation volume (CONS-V) as absolute volume and as a percentage of total lung volume (TLV). The ratio between CONS-V, GGO-V, and VLV (CONS-V/VLV and GGO-V/VLV, respectively), TLV (CONS-V/TLV, GGO-V/TLV, and GGO-V + CONS-V/TLV respectively), and the ratio between VLV and TLV (VLV/TLV) were calculated. RESULTS: A total of 108 patients were enrolled. GGO-V/TLV significantly correlated with WBC (r = 0.369), neutrophils (r = 0.446), platelets (r = 0.182), CRP (r = 0.190), PaCO2 (r = 0.176), HCO3- (r = 0.284), and PaO2/FiO2 (P/F) values (r = - 0.344). CONS-V/TLV significantly correlated with WBC (r = 0.294), neutrophils (r = 0.300), lymphocytes (r = -0.225), CRP (r = 0.306), PaCO2 (r = 0.227), pH (r = 0.162), HCO3- (r = 0.394), and P/F (r = - 0.419) values. Statistically significant differences between CONS-V, GGO-V, GGO-V/TLV, CONS-V/TLV, GGO-V/VLV, CONS-V/VLV, GGO-V + CONS-V/TLV, VLV/TLV, CT score, and invasive ventilation by ET were found (all p < 0.05). CONCLUSION: The use of quantitative semi-automated algorithm for lung CT elaboration effectively correlates the severity of SARS-CoV-2-related pneumonia with laboratory parameters and the need for invasive ventilation. KEY POINTS: • Pathological lung volumes, expressed both as GGO-V and as CONS-V, can be considered a useful tool in SARS-CoV-2-related pneumonia. • All lung volumes, expressed themselves and as ratio with TLV and VLV, correlate with laboratory data, in particular C-reactive protein and white blood cell count. • All lung volumes correlate with patient's outcome, in particular concerning invasive ventilation.


Assuntos
COVID-19 , Pneumonia , Humanos , Pulmão/diagnóstico por imagem , Medidas de Volume Pulmonar , Estudos Retrospectivos , SARS-CoV-2 , Tomografia Computadorizada por Raios X
5.
MAGMA ; 34(1): 133-140, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32562201

RESUMO

OBJECTIVE: To assess whether different Gd-EOB-DTPA injection rates could influence the development of artifacts during the arterial phase of liver MRI studies. MATERIALS AND METHODS: All Gd-EOB-DTPA liver MRI studies performed for different clinical indications at a single tertiary referral center were retrospectively evaluated. Each examination was acquired on a 1.5 T scanner with T1 In- and Out-of-Phase, T2 with and without fat-saturation, DWI, and 3D-T1 fat-sat dynamic sequences. Patients were divided into two groups according to the injection rate (1 ml/s and 1.5 ml/s). A single radiologist recorded the presence or absence of artifacts during different acquisition phases, respectively: (1) all examination; (2) only during the arterial phase; (3) only during the portal-venous phase; (4) both in arterial and portal-venous phases. From a total of 748 MRI studies performed, 229 were excluded due to the presence of artifacts during the entire examination. The remaining 519 MRI studies were divided into two groups according to the injection rate. RESULTS: The first group (flow rate = 1 ml/s) was composed by 312 (60.1%) patients and the second group (flow rate = 1.5 ml/s) by 207 (39.9%) patients. In the first group, 2 (0.6%) patients showed artifacts in all dynamic sequences; 13 (4%) only in the arterial phase, 16 (5%) only in the portal-venous phase, and 38 (12%) both in arterial and portal-venous phases; a total of 243 (78%) showed no artifacts. In the second group, 3 (1.5%) patients had artifacts in all dynamic sequences, 82 (40%) only in the arterial phase, 20 (10%) only in the portal-venous phase, and 53 (25%) both in arterial and portal-venous phases; a total of 49 (23.5%) showed no artifacts. A significant difference between the two groups regarding the absence of artifacts in all examination and the presence of artifacts only during the arterial phase was found (p < 0.001). CONCLUSION: The development of artifacts during the arterial phase of Gd-EOB-DTPA liver MRI studies could be related to the injection rate and its reduction may help to decrease the incidence of artifacts.


Assuntos
Artefatos , Meios de Contraste , Gadolínio DTPA , Humanos , Imageamento por Ressonância Magnética , Estudos Retrospectivos
6.
Radiol Med ; 126(5): 669-678, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33417194

RESUMO

PURPOSE: To analyze pulmonary embolism (PE) on chest computed tomography pulmonary angiography (CTPA) in hospitalized patients affected by SARS-CoV-2, according to the severity of lung disease based both on temporal CT features changes and on CT-severity lung involvement (CT-severity score), along with the support of clinical and laboratory findings. METHODS: We retrospectively enrolled a total of 170 patients with confirmed SARS-CoV-2 infection who underwent CTPA examination for PE suspicion. Pulmonary arteries diameters, right ventricle/left ventricle (RV/LV) ratio, presence, absence, and distribution of PE, pulmonary artery obstructive index (PAO index), and lobe involvement were recorded. All CT scans were reviewed to assess temporal CT changes and the COVID CT-severity score. RESULTS: A total of 76 out of 170 patients (44.7%) developed PE without having any major risk factors for venous thromboembolism. The most severe pulmonary arteries involvement, expressed in terms of PAO Index, occurred in those patients with markedly elevated D-dimer and C-reactive protein (CRP) values and those patients with an advanced temporal stage of lung disease. The majority PE-positive patients were hospitalized in non-intensive wards. PE-positive patients showed a slightly higher hospitalization time in comparison with PE-negative ones. In the three months of study, overall 85.9% of patients were discharged while 14.1% died, of whom 13 PE-positive (54.2%). CONCLUSIONS: Patients hospitalized for SARS-CoV-2 infection present a higher cumulative incidence of PE compared to the general population of hospitalized patients, regardless of the severity of lung inflammation or the temporal stage of the disease.


Assuntos
COVID-19/complicações , Embolia Pulmonar/diagnóstico por imagem , Embolia Pulmonar/etiologia , Doença Aguda , Idoso , Doenças Endêmicas , Feminino , Hospitalização , Humanos , Itália/epidemiologia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Índice de Gravidade de Doença , Tomografia Computadorizada por Raios X
7.
Int J Urol ; 27(10): 866-873, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32713070

RESUMO

OBJECTIVES: To evaluate the diagnostic accuracy of multiparametric magnetic resonance imaging in the detection of prostate cancer, according to Prostate Imaging Reporting and Data System, and the usefulness of combining clinical parameters to improve patients' risk assessment. METHODS: Overall, 201 patients underwent multiparametric magnetic resonance imaging investigation with a 3-T magnet and a 32-channel body coil based on triplanar high-resolution T2-weighted, diffusion-weighted and T1-weighted dynamic contrast-enhanced imaging before, during and after intravenous administration of paramagnetic contrast agent. Random transrectal ultrasound-guided biopsy was carried out for all eligible patients. If a Prostate Imaging Reporting and Data System ≥3 lesion was present, a targeted biopsy with magnetic resonance imaging-transrectal ultrasound fusion-guided system was carried out. RESULTS: Sensitivity, specificity, positive predictive value and negative predictive value of Prostate Imaging Reporting and Data System ≥3 lesions for the detection of prostate cancer were 65.1%, 54.9%, 43.1% and 75.0% respectively, with an accuracy of 64.2% (55.1-72.7%). At uni- and multivariate analysis, age ≥70 years and prostate-specific antigen density ≥0.15 ng/mL/mL were significantly associated with prostate cancer. A new risk model named "modified Prostate Imaging Reporting and Data System" was created considering age and prostate-specific antigen density in addition to the Prostate Imaging Reporting and Data System score showing an improved correlation with prostate cancer compared with the Prostate Imaging Reporting and Data System alone (area under curve 71.4%, 95% confidence interval 62.2-80.5 vs area under curve 62.6%, 95% confidence interval 52.1-73; P ≤ 0.0001). CONCLUSIONS: The accuracy of Prostate Imaging Reporting and Data System alone in the diagnosis of prostate cancer might be suboptimal, whereas a novel risk model based on the combination of multiparametric magnetic resonance imaging data with clinical parameters could offer higher discrimination and improve the ability of diagnosing clinically significant disease.


Assuntos
Imageamento por Ressonância Magnética Multiparamétrica , Neoplasias da Próstata , Idoso , Humanos , Biópsia Guiada por Imagem , Imageamento por Ressonância Magnética , Masculino , Neoplasias da Próstata/diagnóstico por imagem
9.
Eur J Radiol Open ; 12: 100544, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38304573

RESUMO

Pancreatic surgery is nowadays considered one of the most complex surgical approaches and not unscathed from complications. After the surgical procedure, cross-sectional imaging is considered the non-invasive reference standard to detect early and late compilations, and consequently to address patients to the best management possible. Contras-enhanced computed tomography (CECT) should be considered the most important and useful imaging technique to evaluate the surgical site. Thanks to its speed, contrast, and spatial resolution, it can help reach the final diagnosis with high accuracy. On the other hand, magnetic resonance imaging (MRI) should be considered as a second-line imaging approach, especially for the evaluation of biliary findings and late complications. In both cases, the radiologist should be aware of protocols and what to look at, to create a robust dialogue with the surgeon and outline a fitted treatment for each patient.

10.
Expert Rev Endocrinol Metab ; 19(4): 349-366, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38836602

RESUMO

INTRODUCTION: Neuroendocrine neoplasms (NENs) represent a complex group of tumors arising from neuroendocrine cells, characterized by heterogeneous behavior and challenging diagnostics. Despite advancements in medical technology, NENs present a major challenge in early detection, often leading to delayed diagnosis and variable outcomes. This review aims to provide an in-depth analysis of current diagnostic methods as well as the evolving and future directions of diagnostic strategies for NENs. AREA COVERED: The review extensively covers the evolution of diagnostic tools for NENs, from traditional imaging and biochemical tests to advanced genomic profiling and next-generation sequencing. The emerging role of technologies such as artificial intelligence, machine learning, and liquid biopsies could improve diagnostic precision, as could the integration of imaging modalities such as positron emission tomography (PET)/magnetic resonance imaging (MRI) hybrids and innovative radiotracers. EXPERT OPINION: Despite progress, there is still a significant gap in the early diagnosis of NENs. Bridging this diagnostic gap and integrating advanced technologies and precision medicine are crucial to improving patient outcomes. However, challenges such as low clinical awareness, limited possibility of noninvasive diagnostic tools and funding limitations for rare diseases like NENs are acknowledged.


Assuntos
Tumores Neuroendócrinos , Humanos , Tumores Neuroendócrinos/diagnóstico , Tumores Neuroendócrinos/genética , Tumores Neuroendócrinos/diagnóstico por imagem , Tomografia por Emissão de Pósitrons , Detecção Precoce de Câncer/métodos , Medicina de Precisão , Imageamento por Ressonância Magnética/métodos , Sequenciamento de Nucleotídeos em Larga Escala , Inteligência Artificial
11.
Tomography ; 10(2): 286-298, 2024 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-38393291

RESUMO

Aim: To evaluate the dose reduction and image quality of low-dose, low-contrast media volume in computed tomography (CT) examinations reconstructed with the model-based iterative reconstruction (MBIR) algorithm in comparison with the hybrid iterative (HIR) one. Methods: We prospectively enrolled a total of 401 patients referred for cardiovascular CT, evaluated with a 256-MDCT scan with a low kVp (80 kVp) reconstructed with an MBIR (study group) or a standard HIR protocol (100 kVp-control group) after injection of a fixed dose of contrast medium volume. Vessel contrast enhancement and image noise were measured by placing the region of interest (ROI) in the left ventricle, ascending aorta; left, right and circumflex coronary arteries; main, right and left pulmonary arteries; aortic arch; and abdominal aorta. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were computed. Subjective image quality obtained by consensus was assessed by using a 4-point Likert scale. Radiation dose exposure was recorded. Results: HU values of the proximal tract of all coronary arteries; main, right and left pulmonary arteries; and of the aorta were significantly higher in the study group than in the control group (p < 0.05), while the noise was significantly lower (p < 0.05). SNR and CNR values in all anatomic districts were significantly higher in the study group (p < 0.05). MBIR subjective image quality was significantly higher than HIR in CCTA and CTPA protocols (p < 0.05). Radiation dose was significantly lower in the study group (p < 0.05). Conclusions: The MBIR algorithm combined with low-kVp can help reduce radiation dose exposure, reduce noise, and increase objective and subjective image quality.


Assuntos
Meios de Contraste , Tomografia Computadorizada por Raios X , Humanos , Estudos de Viabilidade , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Algoritmos
12.
Eur J Radiol ; 171: 111297, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38237517

RESUMO

Hepatic diffuse conditions and focal liver lesions represent two of the most common scenarios to face in everyday radiological clinical practice. Thanks to the advances in technology, radiology has gained a central role in the management of patients with liver disease, especially due to its high sensitivity and specificity. Since the introduction of computed tomography (CT) and magnetic resonance imaging (MRI), radiology has been considered the non-invasive reference modality to assess and characterize liver pathologies. In recent years, clinical practice has moved forward to a quantitative approach to better evaluate and manage each patient with a more fitted approach. In this setting, radiomics has gained an important role in helping radiologists and clinicians characterize hepatic pathological entities, in managing patients, and in determining prognosis. Radiomics can extract a large amount of data from radiological images, which can be associated with different liver scenarios. Thanks to its wide applications in ultrasonography (US), CT, and MRI, different studies were focused on specific aspects related to liver diseases. Even if broadly applied, radiomics has some advantages and different pitfalls. This review aims to summarize the most important and robust studies published in the field of liver radiomics, underlying their main limitations and issues, and what they can add to the current and future clinical practice and literature.


Assuntos
Neoplasias Hepáticas , Radiômica , Humanos , Tomografia Computadorizada por Raios X , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/patologia , Radiografia , Imageamento por Ressonância Magnética
13.
Eur J Surg Oncol ; : 108274, 2024 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-38538504

RESUMO

INTRODUCTION: Microvascular invasion (MVI) is the main risk factor for overall mortality and recurrence after surgery for hepatocellular carcinoma (HCC).The aim was to train machine-learning models to predict MVI on preoperative CT scan. METHODS: 3-phases CT scans were retrospectively collected among 4 Italian centers. DICOM files were manually segmented to detect the liver and the tumor(s). Radiomics features were extracted from the tumoral, peritumoral and healthy liver areas in each phase. Principal component analysis (PCA) was performed to reduce the dimensions of the dataset. Data were divided between training (70%) and test (30%) sets. Random-Forest (RF), fully connected MLP Artificial neural network (neuralnet) and extreme gradient boosting (XGB) models were fitted to predict MVI. Prediction accuracy was estimated in the test set. RESULTS: Between 2008 and 2022, 218 preoperative CT scans were collected. At the histological specimen, 72(33.02%) patients had MVI. First and second order radiomics features were extracted, obtaining 672 variables. PCA selected 58 dimensions explaining >95% of the variance.In the test set, the XGB model obtained Accuracy = 68.7% (Sens: 38.1%, Spec: 83.7%, PPV: 53.3% and NPV: 73.4%). The neuralnet showed an Accuracy = 50% (Sens: 52.3%, Spec: 48.8%, PPV: 33.3%, NPV: 67.7%). RF was the best performer (Acc = 96.8%, 95%CI: 0.91-0.99, Sens: 95.2%, Spec: 97.6%, PPV: 95.2% and NPV: 97.6%). CONCLUSION: Our model allowed a high prediction accuracy of the presence of MVI at the time of HCC diagnosis. This could lead to change the treatment allocation, the surgical extension and the follow-up strategy for those patients.

14.
Diagnostics (Basel) ; 13(11)2023 May 26.
Artigo em Inglês | MEDLINE | ID: mdl-37296708

RESUMO

During the waves of the coronavirus disease (COVID-19) pandemic, emergency departments were overflowing with patients suffering with suspected medical or surgical issues. In these settings, healthcare staff should be able to deal with different medical and surgical scenarios while protecting themselves against the risk of contamination. Various strategies were used to overcome the most critical issues and guarantee quick and efficient diagnostic and therapeutic charts. The use of saliva and nasopharyngeal swab Nucleic Acid Amplification Tests (NAAT) in the diagnosis of COVID-19 was one of the most adopted worldwide. However, NAAT results were slow to report and could sometimes create significant delays in patient management, especially during pandemic peaks. On these bases, radiology has played and continues to play an essential role in detecting COVID-19 patients and solving differential diagnosis between different medical conditions. This systematic review aims to summarize the role of radiology in the management of COVID-19 patients admitted to emergency departments by using chest X-rays (CXR), computed tomography (CT), lung ultrasounds (LUS), and artificial intelligence (AI).

15.
World J Gastroenterol ; 29(11): 1669-1684, 2023 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-37077517

RESUMO

Since hepatocellular carcinoma (HCC) represents an important cause of mortality and morbidity all over the world. Currently, it is fundamental not only to achieve a curative treatment but also to manage in the best way any possible recurrence. Even if the latest update of the Barcelona Clinic Liver Cancer guidelines for HCC treatment has introduced new locoregional techniques and confirmed others as well-established clinical practices, there is still no consensus about the treatment of recurrent HCC (RHCC). Locoregional treatments and medical therapy represent two of the most widely accepted approaches for disease control, especially in the advanced stage of liver disease. Different medical treatments are now approved, and others are under investigation. On this basis, radiology plays a central role in the diagnosis of RHCC and the assessment of response to locoregional treatments and medical therapy for RHCC. This review summarized the actual clinical practice by underlining the importance of the radiological approach both in the diagnosis and treatment of RHCC.


Assuntos
Técnicas de Ablação , Carcinoma Hepatocelular , Neoplasias Hepáticas , Conduta do Tratamento Medicamentoso , Humanos , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/patologia , Carcinoma Hepatocelular/terapia , Imunoterapia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/patologia , Neoplasias Hepáticas/terapia , Imageamento por Ressonância Magnética , Tomografia Computadorizada por Raios X
16.
Abdom Radiol (NY) ; 48(4): 1215-1226, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36745207

RESUMO

PURPOSE: To assess the agreement between radiologists in the detection of specific features related to T- and N-stage and evaluate accuracy in colon cancer staging. METHODS: Patients who underwent contrast-enhanced computed tomography (CECT) before surgery were enrolled and evaluated by three radiologists with different experience. Pathological data were used as the reference standard. Tumor location, presence of tumor bulging, fat stranding, lateroconal fascia invasion, enlarged vessels, axial short diameter of the biggest node, shape, enhancement pattern, intranodal necrosis, and cluster were collected. Reliability analysis was performed with κ statistics and intraclass correlation coefficients (ICCs). Logistic regressions were used to determine independent predictors associated with staging. RESULTS: Seventy five patients were evaluated. The reliability analysis was moderate to substantial for tumor location (κ = 0.853), T staging (κ = 0.531), tumor bulging (κ = 0.478), fat stranding (κ = 0.490), lateroconal fascia invasion (κ = 0.436), enlarged vessels (κ = 0.401), the axial short diameter of the biggest node (ICC = 0.732), shape (κ = 0.484), enhancement pattern (κ = 0.431), intranodal necrosis (κ = 0.606), and cluster (κ = 0.358). For all readers, sensitivity was higher for T3 lesions (60-69%) and specificity was higher for T2 and T4 lesions (84.5-90.0% and 82.4-85.1%). The diagnostic accuracy was acceptable for all lesions and among all readers (50.7-92.1%). The lateroconal fascia invasion and enlarged vessels resulted as independent predictor factors (OR = 3.292 and OR = 2.651) for T staging, while nodes' cluster and dimension as independent predictor factors of N staging [OR = 3.798 and OR = 1.083]. CONCLUSION: Reader's experience is one of the most important factors associated with the correct classification of colon cancer. Moreover, CECT can help depict radiological features independently associated with the T and N stages.


Assuntos
Neoplasias do Colo , Humanos , Estadiamento de Neoplasias , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Neoplasias do Colo/diagnóstico por imagem , Neoplasias do Colo/cirurgia , Neoplasias do Colo/patologia , Tomografia Computadorizada por Raios X/métodos , Radiologistas
17.
Updates Surg ; 75(8): 2297-2303, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37202600

RESUMO

Derangements of body composition affect surgical outcomes. Chronic statin use may induce muscle wasting and impair muscle tissue quality. Aim of this study was to evaluate the association of chronic statin use, skeletal muscle area (SMA), myosteatosis and major postoperative morbidity. Between 2011 and 2021, patients undergoing pancreatoduodenectomy or total gastrectomy for cancer, and using statins since at least 1 year, were retrospective studied. SMA and myosteatosis were measured at CT scan. The cut-off for SMA and myosteatosis were determined using ROC curve and considering severe complications as the binary outcome. The presence of myopenia was defined when SMA was lower that the cut-off. A multivariable logistic regression was applied to assess the association between several factors and severe complications. After a matching procedure (1:1) for key baseline risk factors (ASA; age; Charlson comorbidity index; tumor site; intraoperative blood loss), a final sample of 104 patients, of which 52 treated and 52 not treated with statins, was obtained. The median age was 75 years, with an ASA score ≥ 3 in 63% of the cases. SMA (OR 5.119, 95% CI 1.053-24.865) and myosteatosis (OR 4.234, 95% CI 1.511-11.866) below the cut-off values were significantly associated with major morbidity. Statin use was predictive of major complication only in patients with preoperative myopenia (OR 5.449, 95% CI 1.054-28.158). Myopenia and myosteatosis were independently associated with an increased risk of severe complications. Statin use was associated with a higher risk of having major morbidity only in the subgroup of patients with myopenia.


Assuntos
Neoplasias Colorretais , Neoplasias Gastrointestinais , Inibidores de Hidroximetilglutaril-CoA Redutases , Sarcopenia , Humanos , Idoso , Inibidores de Hidroximetilglutaril-CoA Redutases/efeitos adversos , Sarcopenia/complicações , Estudos Retrospectivos , Neoplasias Colorretais/cirurgia , Neoplasias Gastrointestinais/cirurgia , Morbidade
18.
Diagnostics (Basel) ; 13(7)2023 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-37046494

RESUMO

Gastric cancer represents one of the most common oncological causes of death worldwide. In order to treat patients in the best possible way, the staging of gastric cancer should be accurate. In this regard, endoscopy ultrasound (EUS) has been considered the reference standard for tumor (T) and nodal (N) statuses in recent decades. However, thanks to technological improvements, computed tomography (CT) has gained an important role, not only in the assessment of distant metastases (M status) but also in T and N staging. In addition, magnetic resonance imaging (MRI) can contribute to the detection and staging of primary gastric tumors thanks to its excellent soft tissue contrast and multiple imaging sequences without radiation-related risks. In addition, MRI can help with the detection of liver metastases, especially small lesions. Finally, positron emission tomography (PET) is still considered a useful diagnostic tool for the staging of gastric cancer patients, with a focus on nodal metastases and peritoneal carcinomatosis. In addition, it may play a role in the treatment of gastric cancer in the coming years thanks to the introduction of new labeling peptides. This review aims to summarize the most common advantages and pitfalls of EUS, CT, MRI and PET in the TNM staging of gastric cancer patients.

19.
World J Gastroenterol ; 29(5): 834-850, 2023 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-36816623

RESUMO

During the first wave of the pandemic, coronavirus disease 2019 (COVID-19) infection has been considered mainly as a pulmonary infection. However, different clinical and radiological manifestations were observed over time, including involvement of abdominal organs. Nowadays, the liver is considered one of the main affected abdominal organs. Hepatic involvement may be caused by either a direct damage by the virus or an indirect damage related to COVID-19 induced thrombosis or to the use of different drugs. After clinical assessment, radiology plays a key role in the evaluation of liver involvement. Ultrasonography (US), computed tomography (CT) and magnetic resonance imaging (MRI) may be used to evaluate liver involvement. US is widely available and it is considered the first-line technique to assess liver involvement in COVID-19 infection, in particular liver steatosis and portal-vein thrombosis. CT and MRI are used as second- and third-line techniques, respectively, considering their higher sensitivity and specificity compared to US for assessment of both parenchyma and vascularization. This review aims to the spectrum of COVID-19 liver involvement and the most common imaging features of COVID-19 liver damage.


Assuntos
COVID-19 , Hepatopatias , Trombose , Humanos , Radiografia , Teste para COVID-19
20.
Diagnostics (Basel) ; 13(10)2023 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-37238224

RESUMO

The advance in technology allows for the development of different CT scanners in the field of dual-energy computed tomography (DECT). In particular, a recently developed detector-based technology can collect data from different energy levels, thanks to its layers. The use of this system is suited for material decomposition with perfect spatial and temporal registration. Thanks to post-processing techniques, these scanners can generate conventional, material decomposition (including virtual non-contrast (VNC), iodine maps, Z-effective imaging, and uric acid pair images) and virtual monoenergetic images (VMIs). In recent years, different studies have been published regarding the use of DECT in clinical practice. On these bases, considering that different papers have been published using the DECT technology, a review regarding its clinical application can be useful. We focused on the usefulness of DECT technology in gastrointestinal imaging, where DECT plays an important role.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA