Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
2.
Environ Sci Technol ; 44(17): 6775-81, 2010 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-20701281

RESUMO

In an effort to develop a noninvasive method for assessment of cyanobacterial toxins in drinking water, plausible cytotoxicity/inhibition of microcystin-LR and cylindrospermopsin was evaluated by cell-substrate impedance sensing (ECIS) using three different cell lines. Sf9 insect cells were attached to concanavalin A coated gold electrodes, whereas Chinese hamster ovary (CHO) and human embryo kidney (HEK) cells were attached to a fibronectin or laminin coated gold surface. Cytotoxic or inhibitory effects were dependent upon the cell line and the extracellular matrix (ECM) coating. Neither toxin exhibited any appreciable effect on the insect cells. In contrast, cytotoxicity of cylindrospermopsin on CHO cells was attested by both ECIS and viability tests. The half-inhibition concentration (ECIS50) of cylindrospermopsin for CHO cells was approximately 2 microg/mL (ppm) after 20 h of exposure and 4 microg/mL (ppm) after 30 h of exposure for a laminin or fibronectin coated surface. ECIS confirmed no significant effect of cylindrospermopsin on HEK cells. Microcystin-LR was also tested with CHO cells, resulting in an ECIS50 value of approximately 12 microg/mL (ppm) after 25 h of exposure for a laminin coated gold surface. The effect of microcystin-LR on CHO cells probed by ECIS was inhibitory rather than cytotoxic, as confirmed by cell viability assays.


Assuntos
Espectroscopia Dielétrica/métodos , Microcistinas/farmacologia , Uracila/análogos & derivados , Alcaloides , Animais , Toxinas Bacterianas , Técnicas Biossensoriais , Células CHO , Cricetinae , Cricetulus , Toxinas de Cianobactérias , Impedância Elétrica , Eletrodos , Fibronectinas/farmacologia , Ouro/farmacologia , Células HEK293 , Humanos , Laminina/farmacologia , Toxinas Marinhas , Spodoptera/citologia , Propriedades de Superfície/efeitos dos fármacos , Uracila/farmacologia
3.
Electrophoresis ; 30(11): 1967-75, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19517437

RESUMO

A CD-modified capillary electrophoretic method has been developed for achiral and chiral analysis of seven bioactive compounds isolated from the fruiting body of Antrodia camphorata. Such important target analytes exhibit similar chemical structures and are known for their diverse properties including antioxidant and anticancer effects. The analytes were separated in 25 min using a pH 9.3, 20 mM sodium borate buffer containing 20 mM methyl-beta-CD and 30 mM sulfobutylether-beta-CD. With the exception of the optical isomer pairs (antcin B or zhankuic acid A, zhankuic acid C, and antcin A), the remaining bioactive compounds including the chiral pair antcin C were baseline-separated. Analysis time was noticeably longer to baseline separate all of the above chiral pairs (approximately 38 min) by adding 5% DMF to the running buffer. The migration order was reversed compared with the HPLC elution. More hydrophobic compounds complexed favorably with methyl-beta-CD and emerged earlier in the electropherogram than their more hydrophilic counterparts which were strongly associated with sulfobutylether-beta-CD. The simple capillary electrophoretic method developed was applicable for rapid separation and characterization of several important bioactive compounds isolated from the fruiting body of A. camphorata.


Assuntos
Antrodia/química , Ciclodextrinas/química , Eletroforese Capilar/métodos , Ergosterol/análogos & derivados , Carpóforos/química , Lanosterol/isolamento & purificação , Absorção , Soluções Tampão , Ergosterol/química , Ergosterol/isolamento & purificação , Etanol/química , Concentração de Íons de Hidrogênio , Lanosterol/análogos & derivados , Lanosterol/química , Sensibilidade e Especificidade , Estereoisomerismo
4.
Analyst ; 134(10): 1965-79, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19768202

RESUMO

In recent years, conductive diamond electrodes for electrochemical applications have been a major focus of research and development. The impetus behind such endeavors could be attributed to their wide potential window, low background current, chemical inertness, and mechanical durability. Several analytes can be oxidized by conducting diamond compared to other carbon-based materials before the breakdown of water in aqueous electrolytes. This is important for detecting and/or identifying species in solution since oxygen and hydrogen evolution do not interfere with the analysis. Thus, conductive diamond electrodes take electrochemical detection into new areas and extend their usefulness to analytes which are not feasible with conventional electrode materials. Different types of diamond electrodes, polycrystalline, microcrystalline, nanocrystalline and ultrananocrystalline, have been synthesized and characterized. Of particular interest is the synthesis of boron-doped diamond (BDD) films by chemical vapor deposition on various substrates. In the tetrahedral diamond lattice, each carbon atom is covalently bonded to its neighbors forming an extremely robust crystalline structure. Some carbon atoms in the lattice are substituted with boron to provide electrical conductivity. Modification strategies of doped diamond electrodes with metallic nanoparticles and/or electropolymerized films are of importance to impart novel characteristics or to improve the performance of diamond electrodes. Biofunctionalization of diamond films is also feasible to foster several useful bioanalytical applications. A plethora of opportunities for nanoscale analytical devices based on conducting diamond is anticipated in the very near future.


Assuntos
Boro/química , Técnicas de Química Analítica/métodos , Diamante/química , Animais , Eletroquímica , Eletrodos , Humanos , Propriedades de Superfície
5.
Analyst ; 134(7): 1447-52, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19562214

RESUMO

A noninvasive technique based on electric cell-substrate impedance sensing (ECIS) was demonstrated for on-line probing inhibitory effects of five destruxins on Spodoptera frugiperda Sf9 insect cells. Such chemically structurally similar cyclic hexadepsipeptides, were isolated and purified from the fungus Metarhizium anisopliae. Based on a response function, the inhibitory effect of the destruxins was established from determining the half-inhibition concentration (ECIS50), i.e., the level at which 50% inhibition of the cell response was obtained. Probing by cell based impedance spectroscopy indicated that only a slight change in their chemical structures provoked a significant effect on inhibition. Destruxin B was most inhibitory but replacement of a single methyl group with hydrogen (destruxin B2) or addition of a hydroxyl group (destruxin C) significantly reduced the inhibition. The removal of one methyl group and one hydrogen (destruxin A) lowered the inhibitory effect even more whereas the formation of an epoxy ring (destruxin E) in the structure nullified the inhibitory effect.


Assuntos
Depsipeptídeos/química , Depsipeptídeos/toxicidade , Metarhizium/química , Spodoptera/citologia , Spodoptera/efeitos dos fármacos , Animais , Adesão Celular/efeitos dos fármacos , Depsipeptídeos/isolamento & purificação , Impedância Elétrica , Análise Espectral , Relação Estrutura-Atividade
6.
Biotechnol Adv ; 37(5): 634-641, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30872068

RESUMO

Biotinylated antibodies/antigens are currently used in many immunoassay formats in clinical settings for diversified analytes and biomarkers to offer high detection selectivity and sensitivity. Biotin cannot be synthesized by mammals and must be taken as an essential supplement. Normal intake of biotin from various foods and milk causes no effect on the streptavidin/biotin-based immunoassays. However, overconsumption of biotin (daily doses 100-300 mg) poses a significant problem for immunoassays using the biotin-strept(avidin) pair. Biotin interferences are noted in immunoassays of thyroid markers, drugs, hormones, cancer markers, the biomarker for cardiac function (ß-human chorionic gonadotropin), etc. The biotin level required for serious interference in test results varies significantly from test to test and cannot easily be predicted. Immunoassay manufacturers with technologies based on strept(avidin)-biotin binding must investigate the interference from biotin (up to at least 1200 ng/mL or 4.9 µM of biotin) in various formats. There is no concrete solution to circumvent the biotin interference encountered in blood samples, short of biotin removal. Considering the short half-life of biotin in the human body, patients must stop taking biotin supplements for >48 h before the test. However, this scenario is not considered for patients in emergency situations or those with biotinidase deficiency, mitochondrial metabolic disorders or multiple sclerosis. Apparently, a rapid analytical procedure for biotin is urgently needed to quantify for its interference in immunoassays using strep(avidin)-biotin chemistry. To date, there is no quick and reliable procedure for the detection of biotin at below nanomolar levels in blood and biological samples. Traditional lab-based techniques including HPLC/MS-MS cannot process an enormous number of public samples. Biosensors with high detection sensitivity, miniaturization, low cost, and multiplexing have the potential to address this issue.


Assuntos
Biotina/química , Imunoensaio/métodos , Estreptavidina/química , Animais , Artefatos , Biomarcadores/análise , Biomarcadores/sangue , Técnicas Biossensoriais/métodos , Biotina/análise , Biotina/isolamento & purificação , Biotina/uso terapêutico , Humanos , Sensibilidade e Especificidade
7.
Anal Chem ; 80(14): 5487-93, 2008 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-18553941

RESUMO

A continuous online technique based on electric cell-substrate impedance sensing (ECIS) was demonstrated for measuring the concentration and time response function of fibroblastic V79 cells exposed to nanomaterials such as quantum dots (QDs) and fluorescent gold nanoparticles. The half-inhibition concentration, (ECIS50), the required concentration to attain 50% inhibition of the cytotoxic response, was estimated from the response function to ascertain cytotoxicity during the course of measurement. The ECIS50 values agreed well with the results obtained using the standard neutral red assay. Cadmium selenide quantum dots showed direct cytotoxicity with the ECIS assay. For the cadmium telluride quantum dots, significant toxicity could be assigned to free cadmium, although additional toxicity could be attributed to the QDs per se. The QDs synthesized with indium gallium phosphide and the fluorescent gold nanoparticles were not cytotoxic.


Assuntos
Ouro/química , Ouro/toxicidade , Nanopartículas Metálicas/química , Pontos Quânticos , Análise Espectral/métodos , Animais , Cádmio/química , Cádmio/farmacologia , Linhagem Celular , Tamanho Celular/efeitos dos fármacos , Cricetinae , Íons/química
8.
Biotechnol Adv ; 26(5): 492-500, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18577442

RESUMO

Biosensor technology is based on a specific biological recognition element in combination with a transducer for signal processing. Since its inception, biosensors have been expected to play a significant analytical role in medicine, agriculture, food safety, homeland security, environmental and industrial monitoring. However, the commercialization of biosensor technology has significantly lagged behind the research output as reflected by a plethora of publications and patenting activities. The rationale behind the slow and limited technology transfer could be attributed to cost considerations and some key technical barriers. Analytical chemistry has changed considerably, driven by automation, miniaturization, and system integration with high throughput for multiple tasks. Such requirements pose a great challenge in biosensor technology which is often designed to detect one single or a few target analytes. Successful biosensors must be versatile to support interchangeable biorecognition elements, and in addition miniaturization must be feasible to allow automation for parallel sensing with ease of operation at a competitive cost. A significant upfront investment in research and development is a prerequisite in the commercialization of biosensors. The progress in such endeavors is incremental with limited success, thus, the market entry for a new venture is very difficult unless a niche product can be developed with a considerable market volume.


Assuntos
Bioensaio/instrumentação , Bioensaio/tendências , Técnicas Biossensoriais/instrumentação , Técnicas Biossensoriais/tendências , Biotecnologia/instrumentação , Biotecnologia/tendências , Transdutores , Desenho de Equipamento , Marketing/tendências , Avaliação da Tecnologia Biomédica
9.
Chem Res Toxicol ; 21(11): 2127-33, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-18816072

RESUMO

A continuous online technique based on electric cell-substrate impedance sensing (ECIS) was used for probing inhibitory effects on Spodoptera frugiperda Sf9 insect cells exposed to structurally similar compounds isolated and purified from the fruiting bodies of the fungus Antrodia camphorata. Such chemicals consisted of three ergostane-related steroids and five lanosta-related triterpenes, which are known for their diverse properties and use in the formulation of nutraceuticals and functional foods. The half-inhibition concentration (ECIS(50)), the level at which 50% inhibition of the resistance response was obtained, was determined from the response function to establish inhibitory effects of the different isolates. A slight change in their chemical structures resulted in significant effects on inhibition as probed by impedance spectroscopy. The ergostane-related steroids were mostly inhibitory, but replacing their ketone groups with hydrogen or hydroxyl groups significantly reduced the inhibition. Similarly, the addition of methyl or carboxymethyl groups also lowered the inhibition. Removal of the double bond conjugation within the rings (sulfurenic acid) of the isolate drastically reduced the inhibition.


Assuntos
Antrodia/química , Ergosterol/análogos & derivados , Triterpenos/farmacologia , Animais , Linhagem Celular , Impedância Elétrica , Ergosterol/química , Ergosterol/farmacologia , Concentração Inibidora 50 , Análise Espectral , Spodoptera , Relação Estrutura-Atividade , Triterpenos/química
11.
J Chromatogr A ; 1103(2): 248-56, 2006 Jan 27.
Artigo em Inglês | MEDLINE | ID: mdl-16337212

RESUMO

The capabilities of using boron-doped diamond (BDD) thin films as electrode materials for analysis of the 16 US Environmental Protection Agency (EPA) priority polyaromatic hydrocarbons (PAHs) after a liquid chromatographic separation were evaluated. The BDD electrode was able to detect all 16 PAHs with high sensitivity due to the low background current and wide potential window. The method provided detection limits ranging from 12-40 nM (3-10 ppb) and repeatable results over consecutive analysis. Calibration curves were linear up to at least 10 microM for all PAHs. The work shows the promising use of diamond as an amperometric detector in high performance liquid chromatography (HPLC), especially for PAHs and other hydrophobic aromatic compounds.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Poluentes Ambientais/análise , Hidrocarbonetos Policíclicos Aromáticos/análise , Boro , Diamante , Eletroquímica , Eletrodos , Sensibilidade e Especificidade , Estados Unidos , United States Environmental Protection Agency
12.
Chem Commun (Camb) ; (31): 3924-6, 2005 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-16075073

RESUMO

This communication reveals new and unique optical properties with respect to enhanced fluorescence of gold nanorods as they elongate; a novel strategy for DNA hybridization studies based on monitoring the fluorescence intensity of gold nanorods has been demonstrated.


Assuntos
Técnicas Biossensoriais , Ouro/química , Nanoestruturas , Sequência de Bases , Primers do DNA , Espectrometria de Fluorescência , Espectrofotometria Ultravioleta
13.
J Chromatogr A ; 1003(1-2): 167-78, 2003 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-12899306

RESUMO

We present cyclodextrin-modified capillary electrophoresis equipped with a microfabricated chip consisting of an array of eight interdigitated microband platinum electrodes (IDs) for simultaneous analysis of three chiral models: epinephrine, norepinephrine and isoproterenol. The IDE chip, positioned very close to the capillary outlet, served as an amplification/detection system. Emerging neurotransmitters at the IDE surface were oxidized at +1.1 V by seven electrodes of the array and then detected by the remaining electrode, poised at +0.0 V. There was an amplification effect on the detecting electrode owing to the recycle between the reduced and oxidized forms of the optical isomers at the electrode surface. The detecting "amplification" current response was governed by the applied potential, the detecting electrode position, the number of adjacent electrodes used for recycling and the distance between the oxidative and reductive electrodes. The six chiral forms of the three neurotransmitters were resolved using 25 mM heptakis(2,6,di-o-methyl)-beta-cyclodextrin with a detection limit of approximately 5 microM. The scheme detected a reduced compound at a reducing potential instead of conventional oxidation detection to alleviate electrode fouling and electroactive interferences. The concurrent oxidation/reduction detection of compounds also facilitated and ascertained peak identification as interfering compounds were unlikely to have the same oxidative/reductive characteristics and mobilities as the analytes of interrogation.


Assuntos
Ciclodextrinas , Eletrodos , Eletroforese Capilar/métodos , Neurotransmissores/análise , Eletroquímica , Eletroforese Capilar/instrumentação , Epinefrina/análise , Epinefrina/isolamento & purificação , Isoproterenol/análise , Isoproterenol/isolamento & purificação , Norepinefrina/análise , Norepinefrina/isolamento & purificação , Oxirredução , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estereoisomerismo
14.
Anal Chim Acta ; 777: 78-85, 2013 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-23622968

RESUMO

Titanium dioxide (TiO2) nanoparticles (NPs) with different sizes and structures were probed for plausible cytotoxicity using electric cell-substrate impedance sensing (ECIS), a non-invasive and on-line procedure for continuous monitoring of cytotoxicity. For insect cells (Spodoptera frugiperda Sf9), the ECIS50 values, i.e., the concentration required to achieve 50% inhibition of the response, differed depending on the size and shape of the TiO2 nanostructure. The lowest ECIS50 value (158 ppm) was observed for the needle shaped rutile TiO2 (10 nm×40 nm, 15.5 nm nominal particle size), followed by 211 ppm for P-25 (34.1 nm, 80% anatase and 20% rutile), 302 ppm for MTI5 (5.9 nm, 99% anatase) and 417 ppm for Hombitan LW-S bulk TiO2 (169.5 nm, 99% anatase). Exposure of TiO2 NPs to UV light at 254 nm or 365 nm exhibited no significant effect on the ECIS50 value due to the aggregation of TiO2 NPs with diminishing photocatalytic activities. Chinese hamster lung fibroblast V79 cells, exhibited no significant cytotoxicity/inhibition up to 400 ppm with P25, MTI5 and bulk TiO2. However, a noticeable inhibitory effect was observed (ECIS50 value of 251 ppm) with rutile TiO2 as cell spreading on the electrode surface was prevented.


Assuntos
Citotoxinas/toxicidade , Nanopartículas Metálicas/química , Titânio/toxicidade , Animais , Linhagem Celular , Forma Celular , Sobrevivência Celular/efeitos dos fármacos , Cricetinae , Cricetulus , Citotoxinas/química , Impedância Elétrica , Fibroblastos/efeitos dos fármacos , Humanos , Concentração Inibidora 50 , Pulmão/citologia , Tamanho da Partícula , Spodoptera/citologia , Titânio/química
15.
ACS Appl Mater Interfaces ; 5(17): 8796-804, 2013 Sep 11.
Artigo em Inglês | MEDLINE | ID: mdl-23931698

RESUMO

The dynamic batch adsorption of methylene blue (MB), a widely used and toxic dye, onto nanocrystalline cellulose (NCC) and crushed powder of carbon monolith (CM) was investigated using the pseudo-first- and -second-order kinetics. CM outperformed NCC with a maximum capacity of 127 mg/g compared to 101 mg/g for NCC. The Langmuir isotherm model was applicable for describing the binding data for MB on CM and NCC, indicating the homogeneous surface of these two materials. The Gibbs free energy of -15.22 kJ/mol estimated for CM unravelled the spontaneous nature of this adsorbent for MB, appreciably faster than the use of NCC (-4.47 kJ/mol). Both pH and temperature exhibited only a modest effect on the adsorption of MB onto CM. The desorption of MB from CM using acetonitrile was very effective with more than 94 % of MB desorbed from CM within 10 min to allow the reusability of this porous carbon material. In contrast, acetonitrile was less effective than ethanol in desorbing MB from NCC. The two solvents were incapable of completely desorbing MB on commercial granular coal-derived activated carbon.

16.
ACS Appl Mater Interfaces ; 4(7): 3643-9, 2012 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-22746697

RESUMO

Three water-dispersible graphene derivatives, graphene oxide (GO), sulfonated graphene oxide (SGO), and sulfonated graphene (SG), were prepared and probed for their plausible cytotoxicity by non-invasive electric cell-substrate impedance sensing (ECIS). With Spodoptera frugiperda Sf9 insect cells adhered on gold microelectrodes as an active interface, it is feasible to monitor changes in impedance upon exposure to different graphene derivatives. Sf9 insect cells were then exposed to different concentrations of graphene derivatives and their spreading and viability were monitored and quantified by ECIS in real-time. On the basis of the 50% inhibition concentration (ECIS50), none of the graphene derivatives were judged to have any significant cytotoxicity with respect to the chosen cell line as the ECIS50 values were all above 100 µg/mL. However, all graphene derivatives exhibited inhibitory effects on the Sf9 response at the cell spreading level with the following order: SG (ECIS50 = 121 ± 8 µg/mL), SGO (ECIS50 = 151 ± 9 µg/mL), and GO (ECIS50 = 232 ± 27 µg/mL), reflecting differences observed in their ζ-potential and surface area. The presence of phenyl sulfonyl groups in SGO and SG improves their aqueous dispersity which enables these materials to have a greater inhibitory effect on Sf9 insect cells in comparison to GO. Such results were corroborated well with the cell count and viability by the Trypan Blue exclusion assay.


Assuntos
Proliferação de Células/efeitos dos fármacos , Rastreamento de Células/métodos , Espectroscopia Dielétrica/métodos , Grafite/farmacologia , Animais , Sobrevivência Celular/efeitos dos fármacos , Sistemas Computacionais , Grafite/química , Teste de Materiais/métodos , Óxidos/química , Óxidos/farmacologia , Células Sf9 , Spodoptera , Alicerces Teciduais/química
17.
Nanoscale ; 4(4): 1373-9, 2012 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-22252333

RESUMO

NCC derived from different biomass sources was probed for its plausible cytotoxicity by electric cell-substrate impedance sensing (ECIS). Two different cell lines, Spodoptera frugiperda Sf9 insect cells and Chinese hamster lung fibroblast V79, were exposed to NCC and their spreading and viability were monitored and quantified by ECIS. Based on the 50%-inhibition concentration (ECIS(50)), none of the NCC produced was judged to have any significant cytotoxicity on these two cell lines. However, NCC derived from flax exhibited the most pronounced inhibition on Sf9 compared to hemp and cellulose powder. NCCs from flax and hemp pre-treated with pectate lyase were also less inhibitory than NCCs prepared from untreated flax and hemp. Results also suggested a correlation between the inhibitory effect and the carboxylic acid contents on the NCC.


Assuntos
Celulose/química , Nanopartículas/química , Animais , Linhagem Celular , Cricetinae , Cricetulus , Eletrodos , Fibroblastos/efeitos dos fármacos , Nanopartículas/toxicidade , Spodoptera/citologia , Spodoptera/efeitos dos fármacos
18.
Trends Biotechnol ; 30(5): 283-90, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22405283

RESUMO

Nanocrystalline cellulose (NCC), a rod-shaped nanoscale material with exceptional strength and physicochemical properties, can be prepared from inexpensive renewable biomass. Besides its potential use as a reinforcing agent for industrial biocomposites, pristine NCC exhibits low toxicity and poses no serious environmental concerns, providing impetus for its use in bioapplications. Here, we review recent developments in the use of modified NCC for emerging bioapplications, specifically enzyme immobilization, antimicrobial and medical materials, green catalysis, biosensing and controlled drug delivery. We focus on the modification of NCC with chemical functionalities and inorganic nanoparticles, reviewing practical considerations such as reusability, toxicity and scale-up capability.


Assuntos
Celulose/metabolismo , Celulose/ultraestrutura , Nanotubos/química , Biomassa , Biotecnologia/métodos
19.
Methods Mol Biol ; 751: 505-32, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21674352

RESUMO

Bioconjugation of carbon nanotubes (CNTs) with biomolecules promises exciting applications such as biosensing, nanobiocomposite formulation, design of drug vector systems, and probing protein interactions. Pristine CNTs, however, are virtually water-insoluble and difficult to evenly disperse in a liquid matrix. Therefore, it is necessary to attach molecules or functional groups to their sidewalls to enable bioconjugation. Both noncovalent and covalent procedures can be used to conjugate CNTs with a target biomolecule for a specific bioapplication. This chapter presents a few selected protocols that can be performed at any wet chemistry laboratory to purify and biofunctionalize CNTs. The preparation of CNTs modified with metallic nanoparticles, especially gold, is also described since biomolecules can bind and self-organize on the surfaces of such metal-decorated CNTs.


Assuntos
Nanotubos de Carbono/química , Boroidretos/química , Ácidos Carboxílicos/química , Compostos Férricos/química , Ouro/química , Proteínas Imobilizadas/química , Líquidos Iônicos/química , Fenômenos Mecânicos , Nanopartículas Metálicas/química , Ácido Nítrico/química , Oxirredução , Polietilenoimina/química , Polímeros/química , Pirenos/química , Silício/química , Solubilidade , Eletricidade Estática , Ácidos Sulfônicos/química , Ácidos Sulfúricos/química , Água/química
20.
ACS Appl Mater Interfaces ; 2(10): 2924-32, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20919683

RESUMO

Probing of cellular uptake and cytotoxicity was conducted for two fluorescent cellulose nanocrystals (CNCs): CNC-fluorescein isothiocyanate (FITC) and newly synthesized CNC-rhodamine B isothiocyanate (RBITC). The positively charged CNC-RBITC was uptaken by human embryonic kidney 293 (HEK 293) and Spodoptera frugiperda (Sf9) cells without affecting the cell membrane integrity. The cell viability assay and cell-based impedance spectroscopy revealed no noticeably cytotoxic effect of the CNC-RBITC conjugate. However, no significant internalization of negatively charged CNC-FITC was observed at physiological pH. Indeed, the effector cells were surrounded by CNC-FITC, leading to eventual cell rupture. As the surface charge of CNC played an important role in cellular uptake and cytotoxicity, facile surface functionalization together with observed noncytotoxicity rendered modified CNC as a promising candidate for bioimaging and drug delivery systems.


Assuntos
Permeabilidade da Membrana Celular/efeitos dos fármacos , Membrana Celular/metabolismo , Celulose/farmacocinética , Fluoresceína-5-Isotiocianato/farmacologia , Corantes Fluorescentes/farmacologia , Nanopartículas , Rodaminas/farmacologia , Animais , Sobrevivência Celular/efeitos dos fármacos , Celulose/química , Fluoresceína-5-Isotiocianato/química , Corantes Fluorescentes/química , Células HEK293 , Humanos , Rodaminas/química , Spodoptera
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA