Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 94
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 97(4): E552-E559, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32779877

RESUMO

OBJECTIVES: We sought to identify baseline demographics and procedural factors that might independently predict in-hospital stroke following transcatheter aortic valve implantation (TAVI). BACKGROUND: Stroke is a recognized, albeit infrequent, complication of TAVI. Established predictors of procedure-related in-hospital stroke; however, remain poorly defined. METHODS: We conducted an observational cohort analysis of the multicenter UK TAVI registry. The primary outcome measure was the incidence of in-hospital stroke. RESULTS: A total of 8,652 TAVI procedures were performed from 2007 to 2015. There were 205 in-hospital strokes reported by participating centers equivalent to an overall stroke incidence of 2.4%. Univariate analysis showed that the implantation of balloon-expandable valves caused significantly fewer strokes (balloon-expandable 96/4,613 [2.08%] vs. self-expandable 95/3,272 [2.90%]; p = .020). After multivariable analysis, prior cerebrovascular disease (CVD) (odds ratio [OR] 1.51, 95% confidence interval [CI 1.05-2.17]; p = .03), advanced age at time of operation (OR 1.02 [0.10-1.04]; p = .05), bailout coronary stenting (OR 5.94 [2.03-17.39]; p = .008), and earlier year of procedure (OR 0.93 [0.87-1.00]; p = .04) were associated with an increased in-hospital stroke risk. There was a reduced stroke risk in those who had prior cardiac surgery (OR 0.62 [0.41-0.93]; p = .01) and a first-generation balloon-expandable valve implanted (OR 0.72 [0.53-0.97]; p = .03). In-hospital stroke significantly increased 30-day (OR 5.22 [3.49-7.81]; p < .001) and 1-year mortality (OR 3.21 [2.15-4.78]; p < .001). CONCLUSIONS: In-hospital stroke after TAVI is associated with substantially increased early and late mortality. Factors independently associated with in-hospital stroke were previous CVD, advanced age, no prior cardiac surgery, and deployment of a predominantly first-generation self-expandable transcatheter heart valve.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estudos de Coortes , Hospitais , Humanos , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Reino Unido/epidemiologia
2.
Catheter Cardiovasc Interv ; 98(3): E444-E452, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33502784

RESUMO

OBJECTIVES: To determine whether a permanent pacemaker (PPM) in situ can enhance survival after transcatheter aortic valve implantation (TAVI), in a predominantly inoperable or high risk cohort. BACKGROUND: New conduction disturbances are the most frequent complication of TAVI, often necessitating PPM implantation before hospital discharge. METHODS: We performed an observational cohort analysis of the UK TAVI registry (2007-2015). Primary and secondary endpoints were 30-day post-discharge all-cause mortality and long-term survival, respectively. RESULTS: Of 8,651 procedures, 6,815 complete datasets were analyzed. A PPM at hospital discharge, irrespective of when implantation occurred (PPM 1.68% [22/1309] vs. no PPM 1.47% [81/5506], odds ratio [OR] 1.14, 95% confidence interval [CI] 0.71-1.84; p = .58), or a PPM implanted peri- or post-TAVI only (PPM 1.44% [11/763] vs. no PPM 1.47% [81/5506], OR 0.98 [0.51-1.85]; p = .95) did not significantly reduce the primary endpoint. Patients with a PPM at discharge were older, male, had right bundle branch block at baseline, were more likely to have received a first-generation self-expandable prosthesis and had experienced more peri- and post-procedural complications including bailout valve-in-valve rescue, bleeding and acute kidney injury. A Cox proportional hazards model demonstrated significantly reduced long-term survival in all those with a PPM, irrespective of implantation timing (hazard ratio [HR] 1.14 [1.02-1.26]; p = .019) and those receiving a PPM only at the time of TAVI (HR 1.15 [1.02-1.31]; p = .032). The reasons underlying this observation warrant further investigation. CONCLUSIONS: A PPM did not confer a survival advantage in the first 30 days after hospital discharge following TAVI.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Assistência ao Convalescente , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Masculino , Alta do Paciente , Complicações Pós-Operatórias , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
3.
Catheter Cardiovasc Interv ; 97(3): 516-526, 2021 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-32865860

RESUMO

OBJECTIVE: To evaluate the incidence, predictors and outcomes of female patients with patient-prosthesis mismatch (PPM) following transcatheter aortic valve intervention (TAVI) for severe aortic stenosis (AS). BACKGROUND: Female AS TAVI recipients have a significantly lower mortality than surgical aortic valve replacement (SAVR) recipients, which could be attributed to the potentially lower PPM rates. TAVI has been associated with lower rates of PPM compared to SAVR. PPM in females post TAVI has not been investigated to date. METHODS: The WIN-TAVI (Women's INternational Transcatheter Aortic Valve Implantation) registry is a multicenter registry of women undergoing TAVR for severe symptomatic AS. Two hundred and fifty patients with detailed periprocedural and follow-up echocardiographic investigations were included in the WIN-TAVI echocardiographic sub-study. PPM was defined as per European guidelines stratified by the presence of obesity. RESULTS: The incidence of PPM in our population was 32.8%. Patients with PPM had significantly higher BMI (27.4 ± 6.1 vs. 25.2 ± 5.0, p = .002), smaller sized valves implanted (percentage of TAVI ≤23 mm 61% vs. 29.2%, PPM vs. no PPM, p < .001) and were more often treated with balloon expandable valves (48.3 vs. 32.5%, p < .001) rather than self expanding ones (26.3 vs. 52.8%, <.001). BMI (OR = 1.08; 95%CI 1.02-1.14, p = .011) and valve size ≤23 mm (OR = 3.00 95%CI 1.14-7.94, p = .027) were the only independent predictors of PPM. There was no significant interaction between valve size and valve type (p = .203). No significant differences were observed in 1-year mortality or major adverse cardiovascular events. CONCLUSIONS: PPM in females undergoing TAVI occurs in one third of patients. BMI and valve size ≤23 mm are independent predictors. Larger registries are required to determine the impact of PPM on future clinical outcomes.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/epidemiologia , Estenose da Valva Aórtica/cirurgia , Feminino , Humanos , Complicações Pós-Operatórias , Prevalência , Sistema de Registros , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
4.
N Engl J Med ; 376(19): 1824-1834, 2017 05 11.
Artigo em Inglês | MEDLINE | ID: mdl-28317458

RESUMO

BACKGROUND: Coronary revascularization guided by fractional flow reserve (FFR) is associated with better patient outcomes after the procedure than revascularization guided by angiography alone. It is unknown whether the instantaneous wave-free ratio (iFR), an alternative measure that does not require the administration of adenosine, will offer benefits similar to those of FFR. METHODS: We randomly assigned 2492 patients with coronary artery disease, in a 1:1 ratio, to undergo either iFR-guided or FFR-guided coronary revascularization. The primary end point was the 1-year risk of major adverse cardiac events, which were a composite of death from any cause, nonfatal myocardial infarction, or unplanned revascularization. The trial was designed to show the noninferiority of iFR to FFR, with a margin of 3.4 percentage points for the difference in risk. RESULTS: At 1 year, the primary end point had occurred in 78 of 1148 patients (6.8%) in the iFR group and in 83 of 1182 patients (7.0%) in the FFR group (difference in risk, -0.2 percentage points; 95% confidence interval [CI], -2.3 to 1.8; P<0.001 for noninferiority; hazard ratio, 0.95; 95% CI, 0.68 to 1.33; P=0.78). The risk of each component of the primary end point and of death from cardiovascular or noncardiovascular causes did not differ significantly between the groups. The number of patients who had adverse procedural symptoms and clinical signs was significantly lower in the iFR group than in the FFR group (39 patients [3.1%] vs. 385 patients [30.8%], P<0.001), and the median procedural time was significantly shorter (40.5 minutes vs. 45.0 minutes, P=0.001). CONCLUSIONS: Coronary revascularization guided by iFR was noninferior to revascularization guided by FFR with respect to the risk of major adverse cardiac events at 1 year. The rate of adverse procedural signs and symptoms was lower and the procedural time was shorter with iFR than with FFR. (Funded by Philips Volcano; DEFINE-FLAIR ClinicalTrials.gov number, NCT02053038 .).


Assuntos
Síndrome Coronariana Aguda/fisiopatologia , Estenose Coronária/fisiopatologia , Estenose Coronária/terapia , Reserva Fracionada de Fluxo Miocárdico , Intervenção Coronária Percutânea/métodos , Síndrome Coronariana Aguda/diagnóstico por imagem , Idoso , Angina Pectoris/diagnóstico por imagem , Angina Pectoris/fisiopatologia , Doenças Cardiovasculares/mortalidade , Angiografia Coronária , Estenose Coronária/diagnóstico por imagem , Feminino , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/epidemiologia , Retratamento , Índice de Gravidade de Doença
5.
Catheter Cardiovasc Interv ; 96(7): E747-E754, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-31631520

RESUMO

Trans-Axillary Transcatheter Aortic Valve Replacement (TAVR) has become established as the safest arterial approach when femoral arterial anatomy is unfavorable. Although a left sided axillary approach is generally preferred, patient specific factors may require use of the right axillary artery. In this case series we describe procedural modifications that are required to overcome the challenge of restricted space in the ascending aorta for in situ valve preparation of balloon-expandable valve systems when a right sided trans-Axillary approach is taken. These steps permit implantation of both the Edwards LifeSciences Sapien 3 and Ultra prostheses via the right trans-Axillary approach, allowing patients a greater range of valve options when this arterial route is required for TAVR.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Artéria Axilar , Cateterismo Periférico , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Cateterismo Periférico/efeitos adversos , Feminino , Humanos , Masculino , Desenho de Prótese , Punções , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
6.
J Thromb Thrombolysis ; 50(1): 82-89, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31605280

RESUMO

The optimal antithrombotic therapy for patients undergoing TAVI with concomitant indication for oral anticoagulation remains unclear. In this high-risk population group, there is a paucity of data with regards to the use of DOACs. In the present study we compared long-term clinical outcomes of TAVI patients requiring anticoagulation, treated with warfarin versus DOACs. Consecutive patients, who underwent TAVI with indication for oral anticoagulation from the multicenter ATLAS registry were studied and divided in two groups depending on the chosen anticoagulation regimen, warfarin vs. DOACs. 30-day survival, as well as estimated 1 and 2-year all-cause mortality were compared between groups. The secondary endpoint included in-hospital major or life-threatening bleeding. The study group included 217 patients (102 treated with warfarin; 115 treated with DOACs). Kaplan-Meier estimated survival was found to be statistically similar in the warfarin and DOAC groups (90.6% vs. 93.7% for 1-year and 84.5% vs. 88.5%, for 2-year survival, respectively, Plog-rank = 0.984). Adjusted hazard ratio for all cause mortality was similar between the two groups (HRwarfarin vs. DOAC = 1.15; 95% CI 0.33 to 4.04, p = 0.829). Propensity matching revealed similar results. At 30-days, all-cause mortality was found to be comparable between the two groups. With regards to BARC defined bleeding complications, major and life-threatening complications did not differ between the two anticoagulation groups (6% vs. 8% for warfarin and DOACs respectively, p = 0.857). DOACs seem to demonstrate a similar safety and efficacy profile compared to warfarin in TAVI patients with a concomitant indication for oral anticoagulation.


Assuntos
Estenose da Valva Aórtica/cirurgia , Inibidores do Fator Xa , Hemorragia , Efeitos Adversos de Longa Duração , Complicações Pós-Operatórias , Trombose , Substituição da Valva Aórtica Transcateter/efeitos adversos , Varfarina , Idoso de 80 Anos ou mais , Anticoagulantes/administração & dosagem , Anticoagulantes/efeitos adversos , Coagulação Sanguínea/efeitos dos fármacos , Inibidores do Fator Xa/administração & dosagem , Inibidores do Fator Xa/efeitos adversos , Feminino , Hemorragia/induzido quimicamente , Hemorragia/diagnóstico , Hemorragia/prevenção & controle , Humanos , Efeitos Adversos de Longa Duração/diagnóstico , Efeitos Adversos de Longa Duração/etiologia , Efeitos Adversos de Longa Duração/mortalidade , Masculino , Seleção de Pacientes , Complicações Pós-Operatórias/sangue , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/prevenção & controle , Prognóstico , Sistema de Registros/estatística & dados numéricos , Análise de Sobrevida , Trombose/sangue , Trombose/etiologia , Trombose/mortalidade , Trombose/prevenção & controle , Substituição da Valva Aórtica Transcateter/métodos , Varfarina/administração & dosagem , Varfarina/efeitos adversos
7.
Eur Heart J ; 40(31): 2620-2629, 2019 08 14.
Artigo em Inglês | MEDLINE | ID: mdl-31220238

RESUMO

AIMS: The public reporting of healthcare outcomes has a number of potential benefits; however, unintended consequences may limit its effectiveness as a quality improvement process. We aimed to assess whether the introduction of individual operator specific outcome reporting after percutaneous coronary intervention (PCI) in the UK was associated with a change in patient risk factor profiles, procedural management, or 30-day mortality outcomes in a large cohort of consecutive patients. METHODS AND RESULTS: This was an observational cohort study of 123 780 consecutive PCI procedures from the Pan-London (UK) PCI registry, from January 2005 to December 2015. Outcomes were compared pre- (2005-11) and post- (2011-15) public reporting including the use of an interrupted time series analysis. Patients treated after public reporting was introduced were older and had more complex medical problems. Despite this, reported in-hospital major adverse cardiovascular and cerebrovascular events rates were significantly lower after the introduction of public reporting (2.3 vs. 2.7%, P < 0.0001). Interrupted time series analysis demonstrated evidence of a reduction in 30-day mortality rates after the introduction of public reporting, which was over and above the existing trend in mortality before the introduction of public outcome reporting (35% decrease relative risk 0.64, 95% confidence interval 0.55-0.77; P < 0.0001). CONCLUSION: The introduction of public reporting has been associated with an improvement in outcomes after PCI in this data set, without evidence of risk-averse behaviour. However, the lower reported complication rates might suggest a change in operator behaviour and decision-making confirming the need for continued surveillance of the impact of public reporting on outcomes and operator behaviour.


Assuntos
Síndrome Coronariana Aguda/cirurgia , Angina Estável/cirurgia , Cardiologistas/psicologia , Análise de Séries Temporais Interrompida/métodos , Administração dos Cuidados ao Paciente/estatística & dados numéricos , Síndrome Coronariana Aguda/diagnóstico , Idoso , Angina Estável/diagnóstico , Doenças Cardiovasculares/epidemiologia , Doenças Cardiovasculares/mortalidade , Estudos de Casos e Controles , Transtornos Cerebrovasculares/epidemiologia , Transtornos Cerebrovasculares/mortalidade , Tomada de Decisão Clínica/ética , Feminino , Mortalidade Hospitalar/tendências , Humanos , Masculino , Notificação de Abuso/ética , Pessoa de Meia-Idade , Administração dos Cuidados ao Paciente/ética , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Intervenção Coronária Percutânea/estatística & dados numéricos , Má Conduta Profissional/estatística & dados numéricos , Estudos Prospectivos , Melhoria de Qualidade/normas , Sistema de Registros , Fatores de Risco , Resultado do Tratamento , Reino Unido/epidemiologia
8.
Circulation ; 138(17): 1780-1792, 2018 10 23.
Artigo em Inglês | MEDLINE | ID: mdl-29789302

RESUMO

BACKGROUND: There are no data on how fractional flow reserve (FFR) and instantaneous wave-free ratio (iFR) are associated with the placebo-controlled efficacy of percutaneous coronary intervention (PCI) in stable single-vessel coronary artery disease. METHODS: We report the association between prerandomization invasive physiology within ORBITA (Objective Randomised Blinded Investigation With Optimal Medical Therapy of Angioplasty in Stable Angina), a placebo-controlled trial of patients who have stable angina with angiographically severe single-vessel coronary disease clinically eligible for PCI. Patients underwent prerandomization research FFR and iFR assessment. The operator was blinded to these values. Assessment of response variables, treadmill exercise time, stress echocardiography score, symptom frequency, and angina severity were performed at prerandomization and blinded follow-up. Effects were calculated by analysis of covariance. The ability of FFR and iFR to predict placebo-controlled changes in response variables was tested by using regression modeling. RESULTS: Invasive physiology data were available in 196 patients (103 PCI and 93 placebo). At prerandomization, the majority had Canadian Cardiovascular Society class II or III symptoms (150/196, 76.5%). Mean FFR and iFR were 0.69±0.16 and 0.76±0.22, respectively; 97% had ≥1 positive ischemia tests. The estimated effect of PCI on between-arm prerandomization-adjusted total exercise time was 20.7 s (95% confidence interval [CI], -4.0 to 45.5; P=0.100) with no interaction of FFR ( Pinteraction=0.318) or iFR ( Pinteraction=0.523). PCI improved stress echocardiography score more than placebo (1.07 segment units; 95% CI, 0.70-1.44; P<0.00001). The placebo-controlled effect of PCI on stress echocardiography score increased progressively with decreasing FFR ( Pinteraction<0.00001) and decreasing iFR ( Pinteraction<0.00001). PCI did not improve angina frequency score significantly more than placebo (odds ratio, 1.64; 95% CI, 0.96-2.80; P=0.072) with no detectable evidence of interaction with FFR ( Pinteraction=0.849) or iFR ( Pinteraction=0.783). However, PCI resulted in more patient-reported freedom from angina than placebo (49.5% versus 31.5%; odds ratio, 2.47; 95% CI, 1.30-4.72; P=0.006) but neither FFR ( Pinteraction=0.693) nor iFR ( Pinteraction=0.761) modified this effect. CONCLUSIONS: In patients with stable angina and severe single-vessel disease, the blinded effect of PCI was more clearly seen by stress echocardiography score and freedom from angina than change in treadmill exercise time. Moreover, the lower the FFR or iFR, the greater the magnitude of stress echocardiographic improvement caused by PCI. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov . Unique identifier: NCT02062593.


Assuntos
Angina Estável/terapia , Cateterismo Cardíaco , Doença da Artéria Coronariana/terapia , Estenose Coronária/terapia , Reserva Fracionada de Fluxo Miocárdico , Intervenção Coronária Percutânea , Agonistas de Receptores Adrenérgicos beta 1/administração & dosagem , Idoso , Angina Estável/diagnóstico , Angina Estável/fisiopatologia , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/fisiopatologia , Estenose Coronária/diagnóstico , Estenose Coronária/fisiopatologia , Dobutamina/administração & dosagem , Ecocardiografia sob Estresse/métodos , Teste de Esforço , Tolerância ao Exercício , Feminino , Nível de Saúde , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Valor Preditivo dos Testes , Intervalo Livre de Progressão , Qualidade de Vida , Recuperação de Função Fisiológica , Índice de Gravidade de Doença , Fatores de Tempo , Reino Unido
9.
Lancet ; 391(10115): 31-40, 2018 01 06.
Artigo em Inglês | MEDLINE | ID: mdl-29103656

RESUMO

BACKGROUND: Symptomatic relief is the primary goal of percutaneous coronary intervention (PCI) in stable angina and is commonly observed clinically. However, there is no evidence from blinded, placebo-controlled randomised trials to show its efficacy. METHODS: ORBITA is a blinded, multicentre randomised trial of PCI versus a placebo procedure for angina relief that was done at five study sites in the UK. We enrolled patients with severe (≥70%) single-vessel stenoses. After enrolment, patients received 6 weeks of medication optimisation. Patients then had pre-randomisation assessments with cardiopulmonary exercise testing, symptom questionnaires, and dobutamine stress echocardiography. Patients were randomised 1:1 to undergo PCI or a placebo procedure by use of an automated online randomisation tool. After 6 weeks of follow-up, the assessments done before randomisation were repeated at the final assessment. The primary endpoint was difference in exercise time increment between groups. All analyses were based on the intention-to-treat principle and the study population contained all participants who underwent randomisation. This study is registered with ClinicalTrials.gov, number NCT02062593. FINDINGS: ORBITA enrolled 230 patients with ischaemic symptoms. After the medication optimisation phase and between Jan 6, 2014, and Aug 11, 2017, 200 patients underwent randomisation, with 105 patients assigned PCI and 95 assigned the placebo procedure. Lesions had mean area stenosis of 84·4% (SD 10·2), fractional flow reserve of 0·69 (0·16), and instantaneous wave-free ratio of 0·76 (0·22). There was no significant difference in the primary endpoint of exercise time increment between groups (PCI minus placebo 16·6 s, 95% CI -8·9 to 42·0, p=0·200). There were no deaths. Serious adverse events included four pressure-wire related complications in the placebo group, which required PCI, and five major bleeding events, including two in the PCI group and three in the placebo group. INTERPRETATION: In patients with medically treated angina and severe coronary stenosis, PCI did not increase exercise time by more than the effect of a placebo procedure. The efficacy of invasive procedures can be assessed with a placebo control, as is standard for pharmacotherapy. FUNDING: NIHR Imperial Biomedical Research Centre, Foundation for Circulatory Health, Imperial College Healthcare Charity, Philips Volcano, NIHR Barts Biomedical Research Centre.


Assuntos
Angina Estável/cirurgia , Estenose Coronária/cirurgia , Intervenção Coronária Percutânea , Idoso , Angina Estável/complicações , Angina Estável/diagnóstico por imagem , Angiografia Coronária , Estenose Coronária/complicações , Estenose Coronária/diagnóstico por imagem , Método Duplo-Cego , Tolerância ao Exercício , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento , Reino Unido
10.
Catheter Cardiovasc Interv ; 93(4): 751-757, 2019 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-30394657

RESUMO

OBJECTIVES: The UK & Ireland Implanters' registry is a multicenter registry which reports on real-world experience with novel transcatheter heart valves. BACKGROUND: The 34 mm Evolut R transcatheter aortic valve is a self-expanding and fully recapturable transcatheter aortic valve, designed to treat patients with a large aortic annulus. METHODS: Between January 2017 and April 2018, clinical, procedural and 30-day outcome data were prospectively collected from all patients receiving the 34 mm Evolut R valve across 17 participating centers in the United Kingdom and Ireland. The primary efficacy outcome was the Valve Academic Research Consortium-2(VARC-2)-defined endpoint of device success. The primary safety outcome was the VARC-2-defined composite endpoint of early safety at 30 days. RESULTS: A total of 217 patients underwent attempted implant. Mean age was 79.5 ± 8.8 years and Society of Thoracic Surgeons Predicted Risk of Mortality Score 5.2% ± 3.4%. Iliofemoral access was used in 91.2% of patients. Device success was 79.7%. Mean gradient was 7.0 ± 4.6 mmHg and effective orifice area 2.0 ± 0.6 cm2 . Paravalvular regurgitation was more than mild in 7.2%. A new permanent pacemaker was implanted in 15.7%. Early safety was demonstrated in 91.2%. At 30 days, all-cause mortality was 3.2%, stroke 3.7%, and major vascular complication 2.3%. CONCLUSIONS: Real-world experience of the 34 mm Evolut R transcatheter aortic valve demonstrated acceptable procedural success, safety, valve function, and incidence of new permanent pacemaker implantation.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Feminino , Hemodinâmica , Humanos , Irlanda , Masculino , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/terapia , Desenho de Prótese , Sistema de Registros , Medição de Risco , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento , Reino Unido
11.
Circulation ; 134(13): 934-44, 2016 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-27587432

RESUMO

BACKGROUND: Paravalvular leak (PVL) occurs in 5% to 17% of patients following surgical valve replacement. Percutaneous device closure represents an alternative to repeat surgery. METHODS: All UK and Ireland centers undertaking percutaneous PVL closure submitted data to the UK PVL Registry. Data were analyzed for association with death and major adverse cardiovascular events (MACE) at follow-up. RESULTS: Three hundred eight PVL closure procedures were attempted in 259 patients in 20 centers (2004-2015). Patient age was 67±13 years; 28% were female. The main indications for closure were heart failure (80%) and hemolysis (16%). Devices were successfully implanted in 91% of patients, via radial (7%), femoral arterial (52%), femoral venous (33%), and apical (7%) approaches. Nineteen percent of patients required repeat procedures. The target valve was mitral (44%), aortic (48%), both (2%), pulmonic (0.4%), or transcatheter aortic valve replacement (5%). Preprocedural leak was severe (61%), moderate (34%), or mild (5.7%) and was multiple in 37%. PVL improved postprocedure (P<0.001) and was none (33.3%), mild (41.4%), moderate (18.6%), or severe (6.7%) at last follow-up. Mean New York Heart Association class improved from 2.7±0.8 preprocedure to 1.6±0.8 (P<0.001) after a median follow-up of 110 (7-452) days. Hospital mortality was 2.9% (elective), 6.8% (in-hospital urgent), and 50% (emergency) (P<0.001). MACE during follow-up included death (16%), valve surgery (6%), late device embolization (0.4%), and new hemolysis requiring transfusion (1.6%). Mitral PVL was associated with higher MACE (hazard ratio [HR], 1.83; P=0.011). Factors independently associated with death were the degree of persisting leak (HR, 2.87; P=0.037), New York Heart Association class (HR, 2.00; P=0.015) at follow-up and baseline creatinine (HR, 8.19; P=0.001). The only factor independently associated with MACE was the degree of persisting leak at follow-up (HR, 3.01; P=0.002). CONCLUSION: Percutaneous closure of PVL is an effective procedure that improves PVL severity and symptoms. Severity of persisting leak at follow-up is independently associated with both MACE and death. Percutaneous closure should be considered as an alternative to repeat surgery.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Valva Mitral/cirurgia , Complicações Pós-Operatórias/etiologia , Falha de Prótese/efeitos adversos , Substituição da Valva Aórtica Transcateter , Adulto , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/métodos , Feminino , Insuficiência Cardíaca/etiologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Irlanda , Masculino , Pessoa de Meia-Idade , Reoperação/métodos , Substituição da Valva Aórtica Transcateter/métodos , Reino Unido
12.
Am J Physiol Heart Circ Physiol ; 310(5): H619-27, 2016 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-26683900

RESUMO

Wave intensity analysis (WIA) has found particular applicability in the coronary circulation where it can quantify traveling waves that accelerate and decelerate blood flow. The most important wave for the regulation of flow is the backward-traveling decompression wave (BDW). Coronary WIA has hitherto always been calculated from invasive measures of pressure and flow. However, recently it has become feasible to obtain estimates of these waveforms noninvasively. In this study we set out to assess the agreement between invasive and noninvasive coronary WIA at rest and measure the effect of exercise. Twenty-two patients (mean age 60) with unobstructed coronaries underwent invasive WIA in the left anterior descending artery (LAD). Immediately afterwards, noninvasive LAD flow and pressure were recorded and WIA calculated from pulsed-wave Doppler coronary flow velocity and central blood pressure waveforms measured using a cuff-based technique. Nine of these patients underwent noninvasive coronary WIA assessment during exercise. A pattern of six waves were observed in both modalities. The BDW was similar between invasive and noninvasive measures [peak: 14.9 ± 7.8 vs. -13.8 ± 7.1 × 10(4) W·m(-2)·s(-2), concordance correlation coefficient (CCC): 0.73, P < 0.01; cumulative: -64.4 ± 32.8 vs. -59.4 ± 34.2 × 10(2) W·m(-2)·s(-1), CCC: 0.66, P < 0.01], but smaller waves were underestimated noninvasively. Increased left ventricular mass correlated with a decreased noninvasive BDW fraction (r = -0.48, P = 0.02). Exercise increased the BDW: at maximum exercise peak BDW was -47.0 ± 29.5 × 10(4) W·m(-2)·s(-2) (P < 0.01 vs. rest) and cumulative BDW -19.2 ± 12.6 × 10(3) W·m(-2)·s(-1) (P < 0.01 vs. rest). The BDW can be measured noninvasively with acceptable reliably potentially simplifying assessments and increasing the applicability of coronary WIA.


Assuntos
Determinação da Pressão Arterial , Circulação Coronária , Vasos Coronários/fisiologia , Ecocardiografia Doppler em Cores , Ecocardiografia Doppler de Pulso , Exercício Físico/fisiologia , Idoso , Pressão Arterial , Velocidade do Fluxo Sanguíneo , Determinação da Pressão Arterial/instrumentação , Artéria Braquial/fisiologia , Cateterismo Cardíaco , Vasos Coronários/diagnóstico por imagem , Teste de Esforço , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Esfigmomanômetros , Fatores de Tempo
13.
J Heart Valve Dis ; 25(2): 211-213, 2016 03.
Artigo em Inglês | MEDLINE | ID: mdl-27989069

RESUMO

Thrombosis of transcatheter aortic valve implantation (TAVI) is an uncommon complication that commonly occurs weeks to months following the procedure. Herein are described the details of a patient who presented with a recurrence of symptoms days after intervention with a bioprosthesis thrombosis that was successfully treated with direct oral anticoagulant (DOAC) therapy and resulted in hemodynamic improvement and resolution of symptoms. Whilst a previous trial of DOAC therapy with mechanical valves was stopped due to elevated events in comparison to warfarin, a TAVI valve may be different, and the rapid onset of action and reduced bleeding risk may be beneficial in this patient group.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Bioprótese , Coagulação Sanguínea/efeitos dos fármacos , Inibidores do Fator Xa/administração & dosagem , Próteses Valvulares Cardíacas , Rivaroxabana/administração & dosagem , Trombose/tratamento farmacológico , Substituição da Valva Aórtica Transcateter/instrumentação , Administração Oral , Idoso de 80 Anos ou mais , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/fisiopatologia , Ecocardiografia Tridimensional , Ecocardiografia Transesofagiana , Hemodinâmica , Humanos , Masculino , Desenho de Prótese , Trombose/sangue , Trombose/etiologia , Fatores de Tempo , Tomografia Computadorizada por Raios X , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
14.
J Heart Valve Dis ; 25(5): 552-556, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-28238236

RESUMO

Transcatheter aortic valve implantation (TAVI) is currently the treatment of choice for patients with severe aortic stenosis (AS) who are unsuitable for surgical aortic valve replacement (SAVR), and is an acceptable alternative for those at high and intermediate surgical risk. In published TAVI registries and meta-analyses, whilst women are significantly older they present with fewer comorbidities compared to men (including coronary artery disease, peripheral vascular disease, diabetes and chronic obstructive pulmonary disease). In response to chronic pressure overload from AS, women have been shown to develop greater levels of left ventricular hypertrophy than men, as well as having a greater preservation of LV ejection fraction (LVEF) and less fibrosis. Following aortic valve replacement, women have been shown to have a faster regression of myocardial hypertrophy, with a significant improvement in LVEF. Following TAVI, female gender seems to be associated with a significantly lower one-year mortality. In the current viewpoint, it is discussed whether these findings reflect a true differential treatment response to TAVI among women, or simply the higher comorbidity burden among males undergoing TAVI.


Assuntos
Estenose da Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/mortalidade , Comorbidade , Humanos , Masculino , Fatores de Risco , Fatores Sexuais , Resultado do Tratamento
15.
Circulation ; 124(14): 1565-72, 2011 Oct 04.
Artigo em Inglês | MEDLINE | ID: mdl-21911781

RESUMO

BACKGROUND: Aortic stenosis causes angina despite unobstructed arteries. Measurement of conventional coronary hemodynamic parameters in patients undergoing valvular surgery has failed to explain these symptoms. With the advent of percutaneous aortic valve replacement (PAVR) and developments in coronary pulse wave analysis, it is now possible to instantaneously abolish the valvular stenosis and to measure the resulting changes in waves that direct coronary flow. METHODS AND RESULTS: Intracoronary pressure and flow velocity were measured immediately before and after PAVR in 11 patients with unobstructed coronary arteries. Using coronary pulse wave analysis, we calculated the intracoronary diastolic suction wave (the principal accelerator of coronary blood flow). To test physiological reserve to increased myocardial demand, we measured at resting heart rate and during pacing at 90 and 120 bpm. Before PAVR, the basal myocardial suction wave intensity was 1.9±0.3×10(-5) W · m(-2) · s(-2), and this increased in magnitude with increasing severity of aortic stenosis (r=0.59, P=0.05). This wave decreased markedly with increasing heart rate (ß coefficient=-0.16×10(-4) W · m(-2) · s(-2); P<0.001). After PAVR, despite a fall in basal suction wave (1.9±0.3 versus 1.1±0.1×10(-5) W · m(-2) · s(-2); P=0.02), there was an immediate improvement in coronary physiological reserve with increasing heart rate (ß coefficient=0.9×10(-3) W · m(-2) · s(-2); P=0.014). CONCLUSIONS: In aortic stenosis, the coronary physiological reserve is impaired. Instead of increasing when heart rate rises, the coronary diastolic suction wave decreases. Immediately after PAVR, physiological reserve returns to a normal positive pattern. This may explain how aortic stenosis can induce anginal symptoms and their prompt relief after PAVR. Clinical Trial Registration- URL: http://www.clinicaltrials.gov. Unique identifier: NCT01118442.


Assuntos
Angina Pectoris/etiologia , Estenose da Valva Aórtica/complicações , Valva Aórtica/cirurgia , Circulação Coronária , Implante de Prótese de Valva Cardíaca , Idoso , Idoso de 80 Anos ou mais , Angina Pectoris/fisiopatologia , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Diástole , Feminino , Frequência Cardíaca , Implante de Prótese de Valva Cardíaca/métodos , Hemodinâmica , Humanos , Hipertrofia Ventricular Esquerda/etiologia , Masculino , Estudos Prospectivos , Fluxo Pulsátil
16.
Eur Heart J ; 32(23): 2970-88, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21609973

RESUMO

AIMS Guidelines suggest that patients should discontinue clopidogrel for 5 days prior to coronary artery bypass grafting (CABG) where possible. Those with acute coronary syndrome (ACS) are at elevated risk of further myocardial infarction (MI) and death without clopidogrel. This meta-analysis aims to determine the risk of CABG in ACS patients while continuing clopidogrel. METHOD AND RESULTS Thirty-four studies with 22 584 patients undergoing CABG were assessed. Patients with recent clopidogrel exposure (CL) were compared with those without recent clopidogrel (NC). Although mortality is increased in CL vs. NC [odds ratio (OR) 1.6, 95% CI 1.30-1.96, P < 0.00001], it is influenced by the ACS status and case urgency in these mainly non-randomized studies. In ACS patients, there is no significant difference in mortality (OR 1.44, 95% CI 0.97-2.1, P= 0.07) or in postoperative MI (OR 0.57, 95% CI 0.31-1.07, P = 0.08) and stroke rates (OR 1.23, 95% CI 0.66-2.29, P = 0.52). Combined major adverse cardiovascular event (stroke, MI, and death) was not different in the two groups (OR 1.10, 95% CI 0.87-1.41, P= 0.43). Reoperation rates are elevated on clopidogrel but have reduced over time, and were specifically not different in ACS patients (OR 1.5, 95% CI 0.88-2.54, P= 0.13). CONCLUSION Previous studies focused on surrogate endpoints and compared higher risk ACS patients with elective cases. However, many patients have safely undergone CABG on clopidogrel and surgical expertise is growing. Multinational trials are required to fully determine the balance of ischaemia and bleeding. While results are awaited we suggest ACS patients requiring urgent CABG proceed with surgery without delay for a clopidogrel-free period.


Assuntos
Síndrome Coronariana Aguda/tratamento farmacológico , Ponte de Artéria Coronária/métodos , Hemorragia/induzido quimicamente , Infarto do Miocárdio/induzido quimicamente , Inibidores da Agregação Plaquetária/efeitos adversos , Acidente Vascular Cerebral/induzido quimicamente , Ticlopidina/análogos & derivados , Síndrome Coronariana Aguda/mortalidade , Síndrome Coronariana Aguda/cirurgia , Transfusão de Sangue/mortalidade , Transfusão de Sangue/estatística & dados numéricos , Clopidogrel , Ponte de Artéria Coronária/mortalidade , Cuidados Críticos/estatística & dados numéricos , Feminino , Hemorragia/mortalidade , Humanos , Tempo de Internação/estatística & dados numéricos , Masculino , Infarto do Miocárdio/mortalidade , Complicações Pós-Operatórias/induzido quimicamente , Complicações Pós-Operatórias/mortalidade , Cuidados Pré-Operatórios , Reoperação/mortalidade , Reoperação/estatística & dados numéricos , Projetos de Pesquisa , Medição de Risco , Fatores de Risco , Acidente Vascular Cerebral/mortalidade , Ticlopidina/efeitos adversos , Resultado do Tratamento
17.
JACC Case Rep ; 4(13): 794-798, 2022 Jul 06.
Artigo em Inglês | MEDLINE | ID: mdl-35818596

RESUMO

Transfemoral transcatheter aortic valve replacement is an effective treatment for severe aortic stenosis with a high rate of procedural success with the current devices. However, anatomic factors and device limitations may increase technical difficulty. We describe the balloon nudge technique, a novel technique that improves coaxial alignment while crossing the aortic valve. (Level of Difficulty: Advanced.).

18.
Cardiovasc Revasc Med ; 36: 153-163, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34366296

RESUMO

Percutaneous closure of paravalvar leaks (PVLs) was once only performed in extreme or non-surgical risk cases not suitable for redo-surgery with tissue or mechanical valves. This technique is now the treatment of choice with long term outcomes that are better than redo operations.123 As interventionalists become more familiar with using PVL devices, more off label device use has been reported in non-surgical cases involving complex native mitral valve regurgitation (NVMR). In this review, we appraise the literature regarding percutaneous treatment of paravalvar leaks and more recently esoteric off label use. We also describe two recent challenging cases where percutaneous devices were used to treat severe leaks that developed as a sequela of previous infective endocarditis. We also provide specific recommendations regarding periprocedural strategy and focus on the importance of device choice to provide an optimal outcome.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , Catéteres , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/cirurgia , Resultado do Tratamento
19.
Eur J Echocardiogr ; 12(12): 904-9, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21900302

RESUMO

AIMS: The CARDia (Coronary Artery Revascularization in Diabetes) trial compared coronary artery bypass grafting (CABG) and optimal percutaneous coronary intervention (PCI) in diabetic patients with multivessel coronary disease. Patients enrolled had symptoms of myocardial ischaemia. As symptom assessment is flawed in diabetic patients, a substudy was undertaken to compare the extent to which these revascularization strategies alter reversible ischaemia. METHODS AND RESULTS: Seventy-one patients underwent stress echo at baseline and at 6 months. A 17-segment echocardiographic wall motion score index (WMSI) was assigned at baseline [WMSI(pre)] and at 6 months [WMSI(post)]. An overall score defined the difference: WMSI(∂) = WMSI(pre)--WMSI(post). Of 71 patients recruited, 42 underwent PCI and 29 CABG. Mean WMSI(pre) in the PCI group was 1.63 and mean WMSI(post) was 1.32. Mean WMSI(pre) in the CABG group was 1.69 and mean WMSI(post) was 1.46. The PCI WMSI(∂) was 0.31 and CABG WMSI(∂) was 0.23 (P = 0.8). Of 42 PCI patients, 39 demonstrated ischaemia at baseline. At 6 months 31 had improvements in ischaemia (79%), 5 showed no improvement, and 3 ischaemia worsened. Of 29 CABG patients, 23 demonstrated ischaemia at baseline. At 6 months, 20 had improvements in ischaemia (87%), 2 had no improvement, and in 1 ischaemia worsened. No difference was seen in the number of patients with improvements in reversible ischaemia between PCI and CABG [79 vs. 87%, (P = 0.9)]. CONCLUSION: Optimal revascularization in diabetic patients with multivessel disease remains controversial. This subset analysis of the CARDia trial suggests both PCI and CABG achieve similar improvement in reversible ischaemia.


Assuntos
Angioplastia Coronária com Balão , Ponte de Artéria Coronária , Isquemia Miocárdica/terapia , Miocárdio/patologia , Idoso , Intervalos de Confiança , Diabetes Mellitus/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/diagnóstico por imagem , Isquemia Miocárdica/cirurgia , Prognóstico , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia
20.
Front Cardiovasc Med ; 8: 748137, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34708094

RESUMO

Background: Trends in mortality from aortic stenosis across European countries are not well-understood, especially given the significant growth in transcatheter aortic valve implantation (TAVI) in the last 10 years. Methods: Age-standardised death rates were extracted from the World Health Organisation Mortality Database, using the International Classification of Diseases 10th edition code for non-rheumatic aortic stenosis for those aged > 45 years between 2000 and 2017. The UK and countries from the European Union with at least 1,000,000 inhabitants and at least 50% available datapoints over the study period were included: a total of 23 countries. Trends were described using Joinpoint regression analysis. Results: No reductions in mortality were demonstrated across all countries 2000-2017. Large increases in mortality were found for Croatia, Poland and Slovakia for both sexes (>300% change). Mortality plateaued in Germany from 2008 in females and 2012 in males, whilst mortality in the Netherlands declined for both sexes from 2007. Mortality differences between the sexes were observed, with greater mortality for males than females across most countries. Conclusions: Mortality from aortic stenosis has increased across Europe from 2000 to 2017. There are, however, sizable differences in mortality trends between Eastern and Western European countries. The need for health resource planning strategies to specifically target AS, particularly given the expected increase with ageing populations, is highlighted.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA