1.
Sensors (Basel) ; 23(8)2023 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-37112454

RESUMO

Blood pressure monitoring is of paramount importance in the assessment of a human's cardiovascular health. The state-of-the-art method remains the usage of an upper-arm cuff sphygmomanometer. However, this device suffers from severe limitations-it only provides a static blood pressure value pair, is incapable of capturing blood pressure variations over time, is inaccurate, and causes discomfort upon use. This work presents a radar-based approach that utilizes the movement of the skin due to artery pulsation to extract pressure waves. From those waves, a set of 21 features was collected and used-together with the calibration parameters of age, gender, height, and weight-as input for a neural network-based regression model. After collecting data from 55 subjects from radar and a blood pressure reference device, we trained 126 networks to analyze the developed approach's predictive power. As a result, a very shallow network with just two hidden layers produced a systolic error of 9.2±8.3 mmHg (mean error ± standard deviation) and a diastolic error of 7.7±5.7 mmHg. While the trained model did not reach the requirements of the AAMI and BHS blood pressure measuring standards, optimizing network performance was not the goal of the proposed work. Still, the approach has displayed great potential in capturing blood pressure variation with the proposed features. The presented approach therefore shows great potential to be incorporated into wearable devices for continuous blood pressure monitoring for home use or screening applications, after improving this approach even further.


Assuntos
Determinação da Pressão Arterial , Radar , Humanos , Pressão Sanguínea/fisiologia , Estudos de Viabilidade , Esfigmomanômetros
2.
Phys Med Biol ; 68(20)2023 Oct 02.
Artigo em Inglês | MEDLINE | ID: mdl-37779386

RESUMO

Objective.Incorporating computed tomography (CT) reconstruction operators into differentiable pipelines has proven beneficial in many applications. Such approaches usually focus on the projection data and keep the acquisition geometry fixed. However, precise knowledge of the acquisition geometry is essential for high quality reconstruction results. In this paper, the differentiable formulation of fan-beam CT reconstruction is extended to the acquisition geometry.Approach.The CT fan-beam reconstruction is analytically derived with respect to the acquisition geometry. This allows to propagate gradient information from a loss function on the reconstructed image into the geometry parameters. As a proof-of-concept experiment, this idea is applied to rigid motion compensation. The cost function is parameterized by a trained neural network which regresses an image quality metric from the motion-affected reconstruction alone.Main results.The algorithm improves the structural similarity index measure (SSIM) from 0.848 for the initial motion-affected reconstruction to 0.946 after compensation. It also generalizes to real fan-beam sinograms which are rebinned from a helical trajectory where the SSIM increases from 0.639 to 0.742.Significance.Using the proposed method, we are the first to optimize an autofocus-inspired algorithm based on analytical gradients. Next to motion compensation, we see further use cases of our differentiable method for scanner calibration or hybrid techniques employing deep models.


Assuntos
Redes Neurais de Computação , Tomografia Computadorizada por Raios X , Imagens de Fantasmas , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Calibragem , Processamento de Imagem Assistida por Computador/métodos , Tomografia Computadorizada de Feixe Cônico , Artefatos
3.
Phys Med Biol ; 67(7)2022 03 21.
Artigo em Inglês | MEDLINE | ID: mdl-35213851

RESUMO

Objective.During x-ray-guided interventional procedures, the medical staff is exposed to scattered ionizing radiation caused by the patient. To increase the staff's awareness of the invisible radiation and monitor dose online, computational scatter estimation methods are convenient. However, such methods are usually based on Monte Carlo (MC) simulations, which are inherently computationally expensive. Yet, in the interventional environment, immediate feedback to the personnel is desirable.Approach. In this work, we propose deep neural networks to mitigate the computational effort of MC simulations. Our learning-based models consider detailed models of the (outer) patient shape and (inner) anatomy, additional objects in the room, and the x-ray tube spectrum to cover imaging settings encountered in real interventional settings. We investigate two cases of scatter prediction. First, we employ network architectures to estimate the full three-dimensional (3D) scatter distribution. Second, we investigate the prediction of two-dimensional (2D) intensity projections that facilitate the intra-procedural visualization.Main results.Depending on the dimensionality of the estimated scatter distribution and the network architecture, the mean relative error of each network is in the range of 12% and 14% compared to MC simulations. However, 3D scatter distributions can be estimated within 60 ms and 2D distributions within 15 ms.Significance.Overall, our method is suitable to support the online assessment of scattered ionizing radiation in the interventional environment and can help to lower the occupational radiation risk.


Assuntos
Redes Neurais de Computação , Radiação Ionizante , Humanos , Método de Monte Carlo , Radiografia , Raios X
4.
Sci Rep ; 12(1): 17540, 2022 10 20.
Artigo em Inglês | MEDLINE | ID: mdl-36266416

RESUMO

Low-dose computed tomography (CT) denoising algorithms aim to enable reduced patient dose in routine CT acquisitions while maintaining high image quality. Recently, deep learning (DL)-based methods were introduced, outperforming conventional denoising algorithms on this task due to their high model capacity. However, for the transition of DL-based denoising to clinical practice, these data-driven approaches must generalize robustly beyond the seen training data. We, therefore, propose a hybrid denoising approach consisting of a set of trainable joint bilateral filters (JBFs) combined with a convolutional DL-based denoising network to predict the guidance image. Our proposed denoising pipeline combines the high model capacity enabled by DL-based feature extraction with the reliability of the conventional JBF. The pipeline's ability to generalize is demonstrated by training on abdomen CT scans without metal implants and testing on abdomen scans with metal implants as well as on head CT data. When embedding RED-CNN/QAE, two well-established DL-based denoisers in our pipeline, the denoising performance is improved by 10%/82% (RMSE) and 3%/81% (PSNR) in regions containing metal and by 6%/78% (RMSE) and 2%/4% (PSNR) on head CT data, compared to the respective vanilla model. Concluding, the proposed trainable JBFs limit the error bound of deep neural networks to facilitate the applicability of DL-based denoisers in low-dose CT pipelines.


Assuntos
Processamento de Imagem Assistida por Computador , Tomografia Computadorizada por Raios X , Humanos , Processamento de Imagem Assistida por Computador/métodos , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X/métodos , Redes Neurais de Computação , Algoritmos , Razão Sinal-Ruído