BMC Vet Res ; 19(1): 141, 2023 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-37660015

RESUMO

BACKGROUND: Upper urinary tract stones are increasingly prevalent in pet cats and are difficult to manage. Surgical procedures to address obstructing ureteroliths have short- and long-term complications, and medical therapies (e.g., fluid diuresis and smooth muscle relaxants) are infrequently effective. Burst wave lithotripsy is a non-invasive, ultrasound-guided, handheld focused ultrasound technology to disintegrate urinary stones, which is now undergoing human clinical trials in awake unanesthetized subjects. RESULTS: In this study, we designed and performed in vitro testing of a modified burst wave lithotripsy system to noninvasively fragment stones in cats. The design accounted for differences in anatomic scale, acoustic window, skin-to-stone depth, and stone size. Prototypes were fabricated and tested in a benchtop model using 35 natural calcium oxalate monohydrate stones from cats. In an initial experiment, burst wave lithotripsy was performed using peak ultrasound pressures of 7.3 (n = 10), 8.0 (n = 5), or 8.9 MPa (n = 10) for up to 30 min. Fourteen of 25 stones fragmented to < 1 mm within the 30 min. In a second experiment, burst wave lithotripsy was performed using a second transducer and peak ultrasound pressure of 8.0 MPa (n = 10) for up to 50 min. In the second experiment, 9 of 10 stones fragmented to < 1 mm within the 50 min. Across both experiments, an average of 73-97% of stone mass could be reduced to fragments < 1 mm. A third experiment found negligible injury with in vivo exposure of kidneys and ureters in a porcine animal model. CONCLUSIONS: These data support further evaluation of burst wave lithotripsy as a noninvasive intervention for obstructing ureteroliths in cats.


Assuntos
Doenças do Gato , Litotripsia , Doenças dos Suínos , Urolitíase , Gatos , Humanos , Animais , Suínos , Litotripsia/veterinária , Rim , Urolitíase/veterinária , Oxalato de Cálcio , Modelos Animais , Doenças do Gato/diagnóstico por imagem , Doenças do Gato/terapia
2.
Proc Natl Acad Sci U S A ; 117(29): 16848-16855, 2020 07 21.
Artigo em Inglês | MEDLINE | ID: mdl-32631991

RESUMO

In certain medical applications, transmitting an ultrasound beam through the skin to manipulate a solid object within the human body would be beneficial. Such applications include, for example, controlling an ingestible camera or expelling a kidney stone. In this paper, ultrasound beams of specific shapes were designed by numerical modeling and produced using a phased array. These beams were shown to levitate and electronically steer solid objects (3-mm-diameter glass spheres), along preprogrammed paths, in a water bath, and in the urinary bladders of live pigs. Deviation from the intended path was on average <10%. No injury was found on the bladder wall or intervening tissue.


Assuntos
Cálculos Renais/terapia , Terapia por Ultrassom/métodos , Ondas Ultrassônicas , Animais , Suínos , Transdutores , Terapia por Ultrassom/instrumentação
3.
J Urol ; 207(5): 1067-1076, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35311351

RESUMO

PURPOSE: We report stone comminution in the first 19 human subjects by burst wave lithotripsy (BWL), which is the transcutaneous application of focused, cyclic ultrasound pulses. MATERIALS AND METHODS: This was a prospective multi-institutional feasibility study recruiting subjects undergoing clinical ureteroscopy (URS) for at least 1 stone ≤12 mm as measured on computerized tomography. During the planned URS, either before or after ureteroscope insertion, BWL was administered with a handheld transducer, and any stone fragmentation and tissue injury were observed. Up to 3 stones per subject were targeted, each for a maximum of 10 minutes. The primary effectiveness outcome was the volume percent comminution of the stone into fragments ≤2 mm. The primary safety outcome was the independent, blinded visual scoring of tissue injury from the URS video. RESULTS: Overall, median stone comminution was 90% (IQR 20, 100) of stone volume with 21 of 23 (91%) stones fragmented. Complete fragmentation (all fragments ≤2 mm) within 10 minutes of BWL occurred in 9 of 23 stones (39%). Of the 6 least comminuted stones, likely causative factors for decreased effectiveness included stones that were larger than the BWL beamwidth, smaller than the BWL wavelength or the introduction of air bubbles from the ureteroscope. Mild reddening of the papilla and hematuria emanating from the papilla were observed ureteroscopically. CONCLUSIONS: The first study of BWL in human subjects resulted in a median of 90% comminution of the total stone volume into fragments ≤2 mm within 10 minutes of BWL exposure with only mild tissue injury.


Assuntos
Cálculos Renais , Litotripsia , Cálculos Ureterais , Humanos , Cálculos Renais/terapia , Litotripsia/efeitos adversos , Litotripsia/métodos , Estudos Prospectivos , Resultado do Tratamento , Cálculos Ureterais/terapia , Ureteroscopia/métodos
4.
Nucleic Acids Res ; 47(12): e69, 2019 07 09.
Artigo em Inglês | MEDLINE | ID: mdl-30927002

RESUMO

Chromatin immunoprecipitation (ChIP) is the most widely used approach for identification of genome-associated proteins and their modifications. We have previously introduced a microplate-based ChIP platform, Matrix ChIP, where the entire ChIP procedure is done on the same plate without sample transfers. Compared to conventional ChIP protocols, the Matrix ChIP assay is faster and has increased throughput. However, even with microplate ChIP assays, sample preparation and chromatin fragmentation (which is required to map genomic locations) remains a major bottleneck. We have developed a novel technology (termed 'PIXUL') utilizing an array of ultrasound transducers for simultaneous shearing of samples in standard 96-well microplates. We integrated PIXUL with Matrix ChIP ('PIXUL-ChIP'), that allows for fast, reproducible, low-cost and high-throughput sample preparation and ChIP analysis of 96 samples (cell culture or tissues) in one day. Further, we demonstrated that chromatin prepared using PIXUL can be used in an existing ChIP-seq workflow. Thus, the high-throughput capacity of PIXUL-ChIP provides the means to carry out ChIP-qPCR or ChIP-seq experiments involving dozens of samples. Given the complexity of epigenetic processes, the use of PIXUL-ChIP will advance our understanding of these processes in health and disease, as well as facilitate screening of epigenetic drugs.


Assuntos
Imunoprecipitação da Cromatina/métodos , Epigênese Genética , Animais , Linhagem Celular , Cromatina/efeitos da radiação , DNA/efeitos da radiação , Células-Tronco Embrionárias/metabolismo , Feminino , Humanos , Masculino , Camundongos Endogâmicos C57BL , RNA Polimerase II/análise , Ondas Ultrassônicas
5.
J Acoust Soc Am ; 150(6): 4203, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34972267

RESUMO

Unlike shock wave lithotripsy, burst wave lithotripsy (BWL) uses tone bursts, consisting of many periods of a sinusoidal wave. In this work, an analytical theoretical approach to modeling mechanical stresses in a spherical stone was developed to assess the dependence of frequency and stone size on stress generated in the stone. The analytical model for spherical stones is compared against a finite-difference model used to calculate stress in nonspherical stones. It is shown that at low frequencies, when the wavelength is much greater than the diameter of the stone, the maximum principal stress is approximately equal to the pressure amplitude of the incident wave. With increasing frequency, when the diameter of the stone begins to exceed about half the wavelength in the surrounding liquid (the exact condition depends on the material of the stone), the maximum stress increases and can be more than six times greater than the incident pressure. These results suggest that the BWL frequency should be elevated for small stones to improve the likelihood and rate of fragmentation.


Assuntos
Cálculos Renais , Litotripsia , Cálculos Urinários , Humanos , Cálculos Renais/terapia , Litotripsia/métodos , Probabilidade , Estresse Mecânico
6.
J Acoust Soc Am ; 148(1): 44, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32752768

RESUMO

Burst wave lithotripsy (BWL) is a technology for comminuting urinary stones. A BWL transducer's requirements of high-pressure output, limited acoustic window, specific focal depth, and frequency to produce fragments of passable size constrain focal beamwidth. However, BWL is most effective with a beam wider than the stone. To produce a broad-beam, an iterative angular spectrum approach was used to calculate a phase screen that was realized with a rapid prototyped lens. The technique did not accurately replicate a target beam profile when an axisymmetric profile was chosen. Adding asymmetric weighting functions to the target profile achieved appropriate beamwidth. Lenses were designed to create a spherically focused narrow-beam (6 mm) and a broad-beam (11 mm) with a 350-kHz transducer and 84-mm focal depth. Both lenses were used to fragment artificial stones (11 mm long) in a water bath, and fragmentation rates were compared. The linearly simulated and measured broad beamwidths that were 12 mm and 11 mm, respectively, with a 2-mm-wide null at center. The broad-beam and the narrow-beam lenses fragmented 44 ± 9% and 16 ± 4% (p = 0.007, N = 3) of a stone by weight, respectively, in the same duration at the same peak negative pressure. The method broadened the focus and improved the BWL rate of fragmentation of large stones.


Assuntos
Cálculos Renais , Litotripsia , Cálculos Urinários , Humanos , Cálculos Renais/diagnóstico por imagem , Cálculos Renais/terapia , Litotripsia/efeitos adversos , Transdutores
7.
J Acoust Soc Am ; 147(3): 1607, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-32237849

RESUMO

Burst wave lithotripsy is a method to noninvasively fragment urinary stones by short pulses of focused ultrasound. In this study, physical mechanisms of stone fracture during burst wave lithotripsy were investigated. Photoelasticity imaging was used to visualize elastic wave propagation in model stones and compare results to numerical calculations. Epoxy and glass stone models were made into rectangular, cylindrical, or irregular geometries and exposed in a degassed water bath to focused ultrasound bursts at different frequencies. A high-speed camera was used to record images of the stone during exposure through a circular polariscope backlit by a monochromatic flash source. Imaging showed the development of periodic stresses in the stone body with a pattern dependent on frequency. These patterns were identified as guided wave modes in cylinders and plates, which formed standing waves upon reflection from the distal surfaces of the stone model, producing specific locations of stress concentration in the models. Measured phase velocities compared favorably to numerically calculated modes dependent on frequency and material. Artificial stones exposed to bursts produced cracks at positions anticipated by this mechanism. These results support guided wave generation and reflection as a mechanism of stone fracture in burst wave lithotripsy.


Assuntos
Cálculos Renais , Litotripsia , Cálculos Urinários , Humanos , Cálculos Renais/diagnóstico por imagem , Cálculos Renais/terapia , Som
8.
J Acoust Soc Am ; 147(6): 3819, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32611160

RESUMO

Theoretical and numerical models were developed to calculate the polariscopic integrated light intensity that forms a projection of the dynamic stress within an axisymmetric elastic object. Although the model is general, this paper addressed its application to measurements of stresses in model kidney stones from a burst wave lithotripter for stone fragmentation. The stress was calculated using linear elastic equations, and the light propagation was modeled in the instantaneous case by integrating over the volume of the stone. The numerical model was written in finite differences. The resulting images agreed well with measured images. The measured images corresponded to the maximum shear stress distribution, although other stresses were also plotted. Comparison of the modeled and observed polariscope images enabled refinement of the photoelastic constant by minimizing the error between the calculated and measured fields. These results enable quantification of the stress within the polariscope images, determination of material properties, and the modes and mechanisms of stress production within a kidney stone. Such a model may help in interpreting elastic waves in structures, such as stones, toward improving lithotripsy procedures.


Assuntos
Cálculos Renais , Litotripsia , Humanos , Cálculos Renais/diagnóstico por imagem , Cálculos Renais/terapia , Estresse Mecânico
9.
J Acoust Soc Am ; 144(5): 2952, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30522301

RESUMO

Combined laboratory experiment and numerical simulation are conducted on bubble clouds nucleated on the surface of a model kidney stone to quantify the energy shielding of the stone caused by cavitation during burst wave lithotripsy (BWL). In the experiment, the bubble clouds are visualized and bubble-scattered acoustics are measured. In the simulation, a compressible, multi-component flow solver is used to capture complex interactions among cavitation bubbles, the stone, and the burst wave. Quantitative agreement is confirmed between results of the experiment and the simulation. In the simulation, a significant shielding of incident wave energy by the bubble clouds is quantified. The magnitude of shielding can reach up to 90% of the energy of the incoming burst wave that otherwise would be transmitted into the stone, suggesting a potential loss of efficacy of stone comminution. There is a strong correlation between the magnitude of the energy shielding and the amplitude of the bubble-scattered acoustics, independent of the initial size and the void fraction of the bubble cloud within a range addressed in the simulation. This correlation could provide for real-time monitoring of cavitation activity in BWL.


Assuntos
Ondas de Choque de Alta Energia/uso terapêutico , Cálculos Renais/terapia , Litotripsia/métodos , Acústica/instrumentação , Algoritmos , Humanos , Litotripsia/instrumentação
10.
J Acoust Soc Am ; 140(2): 1374, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27586763

RESUMO

A generalized Rayleigh-Plesset-type bubble dynamics model with a damage mechanism is developed for cavitation and damage of soft materials by focused ultrasound bursts. This study is linked to recent experimental observations in tissue-mimicking polyacrylamide and agar gel phantoms subjected to bursts of a kind being considered specifically for lithotripsy. These show bubble activation at multiple sites during the initial pulses. More cavities appear continuously through the course of the observations, similar to what is deduced in pig kidney tissues in shock-wave lithotripsy. Two different material models are used to represent the distinct properties of the two gel materials. The polyacrylamide gel is represented with a neo-Hookean elastic model and damaged based upon a maximum-strain criterion; the agar gel is represented with a strain-hardening Fung model and damaged according to the strain-energy-based Griffith's fracture criterion. Estimates based upon independently determined elasticity and viscosity of the two gel materials suggest that bubble confinement should be sufficient to prevent damage in the gels, and presumably injury in some tissues. Damage accumulation is therefore proposed to occur via a material fatigue, which is shown to be consistent with observed delays in widespread cavitation activity.


Assuntos
Resinas Acrílicas , Teste de Materiais/métodos , Estresse Mecânico , Ondas Ultrassônicas , Ágar , Animais , Elasticidade , Litotripsia , Imagens de Fantasmas , Viscosidade
11.
J Urol ; 193(1): 338-44, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25111910

RESUMO

PURPOSE: We developed a new method of lithotripsy that uses short, broadly focused bursts of ultrasound rather than shock waves to fragment stones. We investigated the characteristics of stone comminution by burst wave lithotripsy in vitro. MATERIALS AND METHODS: Artificial and natural stones (mean ± SD size 8.2 ± 3.0 mm, range 5 to 15) were treated with ultrasound bursts using a focused transducer in a water bath. Stones were exposed to bursts with focal pressure amplitude of 6.5 MPa or less at a 200 Hz burst repetition rate until completely fragmented. Ultrasound frequencies of 170, 285 and 800 kHz were applied using 3 transducers, respectively. Time to fragmentation for each stone type was recorded and fragment size distribution was measured by sieving. RESULTS: Stones exposed to ultrasound bursts were fragmented at focal pressure amplitudes of 2.8 MPa or greater at 170 kHz. Fractures appeared along the stone surface, resulting in fragments that separated at the surface nearest to the transducer until the stone was disintegrated. All natural and artificial stones were fragmented at the highest focal pressure of 6.5 MPa with a mean treatment duration of 36 seconds for uric acid stones to 14.7 minutes for cystine stones. At a frequency of 170 kHz the largest artificial stone fragments were less than 4 mm. Exposure at 285 and 800 kHz produced only fragments less than 2 mm and less than 1 mm, respectively. CONCLUSIONS: Stone comminution with burst wave lithotripsy is feasible as a potential noninvasive treatment method for nephrolithiasis. Adjusting the fundamental ultrasound frequency allows for stone fragment size to be controlled.


Assuntos
Litotripsia/métodos , Cálculos Urinários/terapia , Humanos , Técnicas In Vitro
12.
Int J Hyperthermia ; 31(2): 145-62, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25707817

RESUMO

In high intensity focused ultrasound (HIFU) therapy, an ultrasound beam is focused within the body to locally affect the targeted site without damaging intervening tissues. The most common HIFU regime is thermal ablation. Recently there has been increasing interest in generating purely mechanical lesions in tissue (histotripsy). This paper provides an overview of several studies on the development of histotripsy methods toward clinical applications. Two histotripsy approaches and examples of their applications are presented. In one approach, sequences of high-amplitude, short (microsecond-long), focused ultrasound pulses periodically produce dense, energetic bubble clouds that mechanically disintegrate tissue. In an alternative approach, longer (millisecond-long) pulses with shock fronts generate boiling bubbles and the interaction of shock fronts with the resulting vapour cavity causes tissue disintegration. Recent preclinical studies on histotripsy are reviewed for treating benign prostatic hyperplasia (BPH), liver and kidney tumours, kidney stone fragmentation, enhancing anti-tumour immune response, and tissue decellularisation for regenerative medicine applications. Potential clinical advantages of the histotripsy methods are discussed. Histotripsy methods can be used to mechanically ablate a wide variety of tissues, whilst selectivity sparing structures such as large vessels. Both ultrasound and MR imaging can be used for targeting and monitoring the treatment in real time. Although the two approaches utilise different mechanisms for tissue disintegration, both have many of the same advantages and offer a promising alternative method of non-invasive surgery.


Assuntos
Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Humanos , Litotripsia/instrumentação , Neoplasias/terapia , Engenharia Tecidual/métodos
13.
Phys Med Biol ; 69(9)2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38518377

RESUMO

Objective.Histotripsy is a noninvasive focused ultrasound therapy that mechanically disintegrates tissue by acoustic cavitation clouds. In this study, we investigate a mechanism limiting the density of bubbles that can nucleate during a histotripsy pulse. In this mechanism, the pressure generated by the initial bubble expansion effectively negates the incident pressure in the vicinity of the bubble. From this effect, the immediately adjacent tissue is prevented from experiencing the transient tension to nucleate bubbles. Approach.A Keller-Miksis-type single-bubble model was employed to evaluate the dependency of this effect on ultrasound pressure amplitude and frequency, viscoelastic medium properties, bubble nucleus size, and transducer geometric focusing. This model was further combined with a spatial propagation model to predict the peak negative pressure field as a function of position from a cavitating bubble.Main results. The single-bubble model showed the peak negative pressure near the bubble surface is limited to the inertial cavitation threshold. The predicted bubble density increased with increasing frequency, tissue viscosity, and transducer focusing angle. The simulated results were consistent with the trends observed experimentally in prior studies, including changes in density with ultrasound frequency and transducerF-number.Significance.The efficacy of the therapy is dependent on several factors, including the density of bubbles nucleated within the cavitation cloud formed at the focus. These results provide insight into controlling the density of nucleated bubbles during histotripsy and the therapeutic efficacy.


Assuntos
Ondas de Choque de Alta Energia , Ablação por Ultrassom Focalizado de Alta Intensidade , Litotripsia , Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Litotripsia/métodos , Ultrassonografia , Transdutores
14.
Urology ; 185: 131-136, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38281668

RESUMO

OBJECTIVE: To evaluate simulated parastomal herniation forces in in vitro abdominal fascial models. Our group previously illustrated how incision type may play a consequential role in bowel herniation force generated across an incision using several abdominal fascia models. We sought to (1) Confirm findings in fresh human tissue, (2) Assess correlation between herniation force and incision size, and (3) Determine whether incision type impacts drainage in a simulated ex vivo ileal conduit. MATERIALS AND METHODS: Axial tension force (N) of herniation was measured using our previously published protocol, pulling a Foley catheter balloon 3.8 cm diameter affixed to a dynamometer through silicone/fascial incisions ranging 3-5.8 cm. We simulated ileal conduits using bovine small intestine with stoma matured through human fascia using 3.0 cm linear or cruciate incisions. The conduit's caudal end was catheterized and filled at 20 mL/min. Drainage was measured by pad weight change. Two-sided α < 0.05 was used to reject the null hypothesis. RESULTS: Mean (±SD) herniation forces in fresh human fascia varied significantly across linear longitudinal, linear transverse, and cruciate incisions (20.9 ± 3.7, 23.3 ± 8.8, and 8.9 ± 3.8 N, respectively [P = .011]). Fresh human fascial linear incisions 3 cm in diameter had a herniation force of 22.1 ± 6.3 vs 3.5 ± 0.7 N for 5.8 cm incisions when herniating a 3.8 cm balloon (P = .002). All observations were similar in silicone. In simulated ileal conduit, mean drainage: 70.8 ± 3.6 vs 82.1 ± 9.7 mL (linear vs cruciate) after 100 mL instilled, respectively (P = .05). CONCLUSION: This ex vivo study further suggests incision type has predictable influence on herniation force. These data support standardization of urostomy construction techniques and evaluating the clinical impact of stomal maturation techniques on parastomal hernia rates.


Assuntos
Hérnia Ventral , Estomia , Estomas Cirúrgicos , Ferida Cirúrgica , Derivação Urinária , Humanos , Animais , Bovinos , Hérnia Ventral/cirurgia , Silicones , Telas Cirúrgicas
15.
Eur Urol Open Sci ; 54: 66-71, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37485469

RESUMO

Background: Approximately 10 000 patients undergo cystectomy/ileal conduit annually in the USA, of whom over 70% subsequently develop a parastomal hernia (PSH). Still, no well-established "best" practice for stoma creation to prevent a PSH exists. Objective: To measure the relationship between incision size/type/material and axial tension force (ATF) as a surrogate for herniation force, using several models to mimic abdominal fascia. Design setting and participants: Abdominal fascia models included silicone membrane, ex vivo porcine, and embalmed human cadaveric fascia. A dynamometer pulled a Foley catheter (20 mm/min) with the balloon inflated to 125% incision (linear, cruciate, and circular) diameter using a motorized positioning system. The maximum ATF before herniation was recorded. The study was repeated in unused silicone/tissue for suture reinforcement. We evaluated silicone, ex vivo porcine, and human abdominal fascia. Intervention: Incision sizes (1-3 cm) in 0.5-cm increments were evaluated in silicone. A 3-cm incision was used in porcine/human tissue. Outcome measurements and statistical analysis: ATF for herniation was recorded/compared across incision types/sizes using Mann-Whitney U and Kruskal-Wallis tests as appropriate, with α = 0.05. Results and limitations: Linear incision ATF was significantly greater than cruciate and circular incisions. A cruciate incision had significantly greater ATF than a circular incision. In cadaveric tissue, incisions were significantly greater for linear (34.5 ± 12.8 N) versus cruciate (15.3 ± 2.9 N, p = 0.004) and for cruciate versus circular (p = 0.023) incisions. Results were similar in ex vivo porcine fascia and silicone. Reinforcement with a suture significantly increased ATF in all materials/incision sizes/types. The ex vivo nature is this study's main limitation. Conclusions: This study suggests that urostomy fascial incision type may influence ATF required for herniation. Linear incisions may be preferable. Urostomy reinforcement may significantly increase ATF required for a PSH. These data may help establish best practices for PSH risk reduction. Patient summary: The results of this study illustrate that urostomy fascia incision type may influence the force required to create a parastomal hernia. Linear incisions may be preferable.

16.
Sci Rep ; 13(1): 9160, 2023 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-37280230

RESUMO

Acoustic radiation forces can remotely manipulate particles. Forces from a standing wave field align microscale particles along the nodal or anti-nodal locations of the field to form three-dimensional (3D) patterns. These patterns can be used to form 3D microstructures for tissue engineering applications. However, standing wave generation requires more than one transducer or a reflector, which is challenging to implement in vivo. Here, a method is developed and validated to manipulate microspheres using a travelling wave from a single transducer. Diffraction theory and an iterative angular spectrum approach are employed to design phase holograms to shape the acoustic field. The field replicates a standing wave and aligns polyethylene microspheres in water, which are analogous to cells in vivo, at pressure nodes. Using Gor'kov potential to calculate the radiation forces on the microspheres, axial forces are minimized, and transverse forces are maximized to create stable particle patterns. Pressure fields from the phase holograms and resulting particle aggregation patterns match predictions with a feature similarity index > 0.92, where 1 is a perfect match. The resulting radiation forces are comparable to those produced from a standing wave, which suggests opportunities for in vivo implementation of cell patterning toward tissue engineering applications.

17.
Ultrasound Med Biol ; 49(12): 2451-2458, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37718123

RESUMO

OBJECTIVE: Bacterial loads can be effectively reduced using cavitation-mediated focused ultrasound, or histotripsy. In this study, gram-negative bacteria (Escherichia coli) in suspension were used as model bacteria to evaluate the effectiveness of two regimens of histotripsy treatments: cavitation histotripsy (CH) and boiling histotripsy (BH). METHODS: Ten-milliliter volumes of Escherichia coli were treated at different negative focal pressure amplitudes and over time periods up to 40 min. Cavitation activity was characterized with coaxial passive cavitation detection (PCD) and synchronized plane wave B-mode imaging. RESULTS: CH treatments exhibited a threshold behavior that was consistent with PCD metrics of cavitation. Above the threshold, bacterial inactivation followed a monotonically increasing log-linear relationship that indicated an exponential inactivation rate. BH exhibited no threshold, but instead followed a different monotonically increasing inactivation rate. Inactivation rates were larger for BH at or below the CH threshold, and larger for CH substantially above the threshold. CH studies performed at different pulse lengths at the same duty cycle had similar inactivation rates, suggesting that at any given pressure amplitude, the "on time" was the most important variable for inactivating E. coli. The maximum inactivation was produced by CH at the highest pressure amplitudes used, leading to a log reduction >4.2 for a 40 min treatment. CONCLUSION: The results of this study suggest that both CH and BH can be used to inactivate E. coli in suspension, with the optimal regimen depending on the attainable peak negative focal pressure at the target.


Assuntos
Ablação por Ultrassom Focalizado de Alta Intensidade , Litotripsia , Escherichia coli , Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Litotripsia/métodos , Imagens de Fantasmas
18.
Ultrasound Med Biol ; 49(1): 62-71, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36207225

RESUMO

Boiling histotripsy (BH) is a focused ultrasound technology that uses millisecond-long pulses with shock fronts to induce mechanical tissue ablation. The pulsing scheme and mechanisms of BH differ from those of cavitation cloud histotripsy, which was previously developed for benign prostatic hyperplasia. The goal of the work described here was to evaluate the feasibility of using BH to ablate fresh ex vivo human prostate tissue as a proof of principle for developing BH for prostate applications. Fresh human prostate samples (N = 24) were obtained via rapid autopsy (<24 h after death, institutional review board exempt). Samples were analyzed using shear wave elastography to ensure that mechanical properties of autopsy tissue were clinically representative. Samples were exposed to BH using 10- or 1-ms pulses with 1% duty cycle under real-time B-mode and Doppler imaging. Volumetric lesions were created by sonicating 1-4 rectangular planes spaced 1 mm apart, containing a grid of foci spaced 1-2 mm apart. Tissue then was evaluated grossly and histologically, and the lesion content was analyzed using transmission electron microscopy and scanning electron microscopy. Observed shear wave elastography characterization of ex vivo prostate tissue (37.9 ± 22.2 kPa) was within the typical range observed clinically. During BH, hyperechoic regions were visualized at the focus on B-mode, and BH-induced bubbles were also detected using power Doppler. As treatment progressed, hypoechoic regions of tissue appeared, suggesting successful tissue fractionation. BH treatment was twofold faster using shorter pulses (1 ms vs. 10 ms). Histological analysis revealed lesions containing completely homogenized cell debris, consistent with histotripsy-induced mechanical ablation. It was therefore determined that BH is feasible in fresh ex vivo human prostate tissue producing desired mechanical ablation. The study supports further work aimed at translating BH technology as a clinical option for prostate ablation.


Assuntos
Ablação por Ultrassom Focalizado de Alta Intensidade , Masculino , Humanos , Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Próstata/diagnóstico por imagem , Próstata/cirurgia
19.
Ultrasound Med Biol ; 48(9): 1762-1777, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35697582

RESUMO

Tissue-mimicking gels provide a cost-effective medium to optimize histotripsy treatment parameters with immediate feedback. Agarose and polyacrylamide gels are often used to evaluate treatment outcomes as they mimic the acoustic properties and stiffness of a variety of soft tissues, but they do not exhibit high toughness, a characteristic of fibrous connective tissue. To mimic pathologic fibrous tissue found in benign prostate hyperplasia (BPH) and other diseases that are potentially treatable with histotripsy, an optically transparent hydrogel with high toughness was developed that is a hybrid of polyacrylamide and alginate. The stiffness was established using shear wave elastography (SWE) and indentometry techniques and was found to be representative of human BPH ex vivo prostate tissue. Different phantom compositions and excised ex vivo BPH tissue samples were treated with a 700-kHz histotripsy transducer at different pulse repetition frequencies. Post-treatment, the hybrid gels and the tissue samples exhibited differential reduction in stiffness as measured by SWE. On B-mode ultrasound, partially treated areas were present as hyperechoic zones and fully liquified areas as hypoechoic zones. Phase contrast microscopy of the gel samples revealed liquefaction in regions consistent with the target lesion dimensions and correlated to findings identified in tissue samples via histology. The dose required to achieve liquefaction in the hybrid gel was similar to what has been observed in ex vivo tissue and greater than that of agarose of comparable or higher Young's modulus by a factor >10. These results indicate that the developed hydrogels closely mimic elasticities found in BPH prostate ex vivo tissue and have a similar response to histotripsy treatment, thus making them a useful cost-effective alternative for developing and evaluating different treatment protocols.


Assuntos
Ablação por Ultrassom Focalizado de Alta Intensidade , Hiperplasia Prostática , Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Humanos , Hidrogéis , Masculino , Imagens de Fantasmas , Sefarose
20.
Int J Impot Res ; 34(5): 477-486, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34035467

RESUMO

Peyronie's disease affects penile mechanics, but published research lacks biomechanical characterization of affected tunica albuginea. This work aims to establish mechanical testing methodology and characterize pathological tissue mechanics of Peyronie's disease. Tunica albuginea was obtained from patients (n = 5) undergoing reconstructive surgery for Peyronie's disease, sectioned into test specimens (n = 12), stored frozen at -20 °C, and imaged with micro-computed tomography (µCT). A tensile testing protocol was developed based on similar soft tissues. Correlation of mechanical summary variables (force, displacement, stiffness, work, Young's modulus, ultimate tensile stress, strain at ultimate tensile stress, and toughness) and µCT features were assessed with linear regression. Specimens empirically grouped into hard or soft stress-strain behavior were compared using a Student's t-test. Surface strain and failure patterns were described qualitatively. Specimens displayed high inter- and intra-subject variability. Mineralization volume was not correlated with mechanical parameters. Empirically hard tissue had higher ultimate tensile stress. Failure mechanisms and strain patterns differed between mineralized and non-mineralized specimens. Size, shape, and quantity of mineralization may be more important in determining Peyronie's disease plaque behavior than presence of mineralization alone, and single summary variables like modulus may not fully describe mechanical behavior.


Assuntos
Induração Peniana , Fibrose , Humanos , Masculino , Induração Peniana/cirurgia , Pênis/patologia , Microtomografia por Raio-X