Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 47
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Am Heart J ; 264: 114-122, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37315878

RESUMO

BACKGROUND: Transcatheter aortic valve implantation (TAVI) was established as a standard treatment for high-operative risk patients with severe aortic stenosis (AS). Although coronary artery disease (CAD) often coexists with AS, clinical and angiographic evaluations of stenosis severity are unreliable in this specific setting. To provide precise risk stratification of coronary lesions, combined near-infrared spectroscopy and intravascular ultrasound (NIRS-IVUS) was developed to integrate morphological and molecular information on plaque composition. However, there is a lack of evidence on the association between NIRS-IVUS derived findings such as maximum 4mm lipid core burden index (maxLCBI4mm) and clinical outcomes in AS patients undergoing TAVI. This registry aims to assess feasibility and safety of NIRS-IVUS imaging in the setting of routine pre-TAVI coronary angiography to improve assessment of CAD severity. METHODS: The registry is designed as a non-randomized, prospective, observational, multicenter cohort registry. Patients referred for TAVI with angiographic evidence of CAD receive NIRS-IVUS imaging and are followed up to 24 months. Enrolled patients are classified as NIRS-IVUS positive and NIRS-IVUS negative, respectively, based on their maxLCBI4mm to compare their clinical outcomes. The primary endpoint of the registry is major adverse cardiovascular events over a 24-month follow-up period. CONCLUSIONS: Identification of patients likely or unlikely to benefit from revascularization prior to TAVI represents an important unmet clinical need. This registry is designed to investigate whether NIRS-IVUS-derived atherosclerotic plaque characteristics can identify patients and lesions at risk for future adverse cardiovascular events after TAVI, in order to refine interventional decision-making in this challenging patient population.


Assuntos
Doença da Artéria Coronariana , Placa Aterosclerótica , Substituição da Valva Aórtica Transcateter , Humanos , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/cirurgia , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Estudos Prospectivos , Ultrassonografia de Intervenção/métodos , Angiografia Coronária , Sistema de Registros
2.
Catheter Cardiovasc Interv ; 102(7): 1301-1310, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37877190

RESUMO

BACKGROUND: Permanent pacemaker implantation (PPI) remains a relevant complication after transcatheter aortic valve implantation (TAVI) and its impact on outcome remains controversial. AIMS: This study aimed to analyze the effects of implantation depth on PPI at 30 days and assess its impact on outcome with the balloon-expandable Sapien 3 (S3) prosthesis. METHODS: Between 2014 and 2018, 849 patients without previous pacemaker undergoing transfemoral TAVI with the S3 were included. Prosthesis implantation depth was measured and divided into Quintiles. An ordinal logistic regression was used to assess its association with PPI, while a multivariate logistic regression was performed to identify predictors of PPI. Survival analyses were performed with the Kaplan-Meier method and a multivariable Cox regression was performed to ascertain the impact of PPI on mortality. RESULTS: Overall, incidence of PPI at 30 days was 9.7%. Implantation depth decreased consistently from a median of 6.7 mm [5.55-8.00] in 2014 to 2.7 mm [2.30-3.50] in 2018 (p < 0.001). When considering Quintiles of implantation depth, incidence of PPI was significantly higher in upper Quintiles and risk for PPI was significantly lower for the 1. Quintile compared to the 5. Quintile (OR: 0.34, 95% CI: [0.16-0.73]; p = 0.003). In the adjusted multivariable logistic regression implantation depth persisted ad independent predictor of PPI at 30 days. Patients requiring PPI at 30 days displayed significantly higher mortality at 4 years compared to patients without PPI (49.5% vs. 40.0%; log-rank = 0.022). In a multivariate analysis, increased logistic EuroScore, diabetes mellitus, and history of atrial fibrillation, were independent predictors of all-cause mortality at 2 years. CONCLUSIONS: Higher prosthesis implantation relative to the virtual aortic annulus was significantly associated with reduced risk for PPI at 30 days. Patients with PPI at 30 days exhibited higher mortality during follow-up, however, only logistic EuroScore, diabetes mellitus, and history of atrial fibrillation were identified as independent predictors of mortality at 2 years.


Assuntos
Estenose da Valva Aórtica , Fibrilação Atrial , Diabetes Mellitus , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Fibrilação Atrial/etiologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Próteses Valvulares Cardíacas/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Fatores de Risco
3.
J Card Surg ; 36(4): 1241-1248, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33484180

RESUMO

PURPOSE: The Sentinel Cerebral Protection System (Sentinel-CPS) is increasingly used in transcatheter aortic valve replacement (TAVR). However, the impact of inserting the Sentinel-CPS inside the brain-supplying arteries on cerebral perfusion and oxygenation is unknown. METHODS: Twenty patients undergoing transfemoral TAVR with (n = 10) and without (n = 10) cerebral embolic protection using the Sentinel-CPS were prospectively observed. All patients received conscious sedation and cerebral oxygen saturation (rSO2 ) was continuously measured with near-infrared spectroscopy (NIRS). The cumulative perioperative cerebral desaturation was calculated for each patient by multiplying rSO2 below an individualized desaturation threshold by time. In addition, rSO2 values at the time of Sentinel-CPS insertion, filter positioning, and device retraction were analyzed. RESULTS: There was no significant difference in cumulative cerebral desaturation in patients with Sentinel-CPS (median [IQR]) (0 [0/81] s%) and without (median [IQR]) (0 [0/23] s%), p = .762. A total of 6 patients (33.3%) experienced a perioperative decrease in rSO2 below the individualized desaturation threshold (n = 3 with Sentinel-CPS, n = 3 without Sentinel-CPS; p = 1.000). Cerebral desaturation was detected during valve deployment (n = 5) and after postdilatation (n = 1). No desaturation events occurred during Sentinel-CPS insertion, filter positioning, or retraction. CONCLUSION: Our pilot study revealed no difference in cumulative perioperative cerebral desaturation between TAVR with and without Sentinel-CPS. Catheter- and filter-based manipulations in the brain-supplying arteries for Sentinel-CPS application were not associated with a decrease of cerebral perfusion and oxygenation.


Assuntos
Estenose da Valva Aórtica , Dispositivos de Proteção Embólica , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Humanos , Oxigênio , Projetos Piloto , Estudos Prospectivos , Resultado do Tratamento
4.
Heart Lung Circ ; 29(6): 904-913, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31182269

RESUMO

AIM: Psoas muscle cross-sectional area (CSA) is a proposed marker of frailty associated with mortality after transcatheter aortic valve implantation (TAVI). We assessed the impact of psoas CSA on medium-term mortality over 5 years in a large cohort, adjusted for pre-procedural variables. METHOD: This single-centre registry-derived analysis assessed 1,731 consecutive TAVI patients between 2007 and 31 April 2015 with available abdominal computed tomography scans. Sex-stratified, height-adjusted psoas CSA was measured mid-body of the fourth lumbar vertebra. Kaplan-Meier survival distributions across psoas CSA quartiles were compared. Cox and logistic regression models were used to assess baseline variables associated with the primary outcome, which was mortality within 5 years. RESULTS: Median age was 81 years (interquartile range, 77 - 85); 52.5% were women. The primary endpoint occurred in 555 patients over a mean follow-up of 775 days. Lower psoas CSA quartile patients were older, had a lower body mass index, lower creatinine clearance, and lower rates of previous cardiac surgery, with higher rates of diabetes, coronary artery disease, pacemaker, anaemia, hypoalbuminaemia, and higher European System for Cardiac Operative Risk Evaluation (EuroSCORE). Unadjusted survival by psoas CSA quartile was significantly different in men (log rank p=0.041) but not women (p=0.099). In Bonferroni-adjusted multivariate analysis, psoas CSA quartiles were not significantly associated with mortality. Hypoalbuminaemia (hazard ratio [HR], 2.10; 95% confidence interval [CI], 1.53 - 2.87 [p<0.001]) and increasing age (HR, 1.03 per year; 95% CI, 1.01 - 1.05 [p=0.002]) were associated with increased risk; female sex (HR, 0.63; 95% CI 0.51 - 0.78 [p<0.001]), and hypercholesterolaemia (HR, 0.67; 95%, CI 0.54 0.83 [p<0.001]) with reduced risk. CONCLUSIONS: Psoas CSA was not significantly associated with mortality after adjusting for pre-procedural variables. Hypoalbuminaemia, sex, hypercholesterolaemia, and age were significantly associated with mortality after TAVI.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Músculos Psoas/diagnóstico por imagem , Sistema de Registros , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Alemanha/epidemiologia , Humanos , Masculino , Músculos Psoas/cirurgia , Estudos Retrospectivos , Fatores de Risco , Taxa de Sobrevida/tendências , Fatores de Tempo , Tomografia Computadorizada por Raios X , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
5.
Catheter Cardiovasc Interv ; 94(6): 783-792, 2019 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-30801906

RESUMO

OBJECTIVES: To evaluate 1-year outcome using the ACURATE neo (Symetis S.A., a Boston Scientific Company, Ecublens, Switzerland) according to the updated Valve Academic Research Consortium (VARC-2) with emphasis on the composite endpoints "clinical efficacy after 30 days" and "time-related valve safety". BACKGROUND: Initial reports on the clinical performance of patients treated with the ACURATE neo are promising; however, information regarding one-year outcome is scarce, especially with regard to the composite endpoints proposed by the VARC-2. METHODS: One hundred and fifty one consecutive patients undergoing transfemoral transcatheter aortic valve replacement (TAVR) with the ACURATE neo for severe aortic valve stenosis were enrolled. Data were prospectively collected and event rates during follow-up were calculated as the Kaplan-Meier estimates. RESULTS: Mean age was 81.1 ± 5.9 years and 49.7% (75/151) were female with a median logistic EuroScore of 13.8% [8.2-20.5]. Device success was achieved in 88.1% (133/151) and procedure related mortality was 0.7% (1/151). At one-year, all-cause mortality was 3.3% (5/151), while permanent pacemaker implantation occurred in 12.7% (19/151) of patients. The "clinical efficacy after 30 days" was observed in 24.8% (37/151), where the main contributor was symptom worsening in 14.8% (22/151) of cases. "Time-related valve safety" occurred in 22.0% (33/151) with structural valve deterioration as main contributor in 10.7% (16/151) of cases. CONCLUSIONS: Using the ACURATE neo, we found a favorable safety profile with low all-cause mortality at 1 year. The reported VARC-2 defined composite endpoints at 1 year reveal low rates of "clinical efficacy after 30 days" and "time-related valve safety".


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Feminino , Hemodinâmica , Humanos , Masculino , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
6.
Catheter Cardiovasc Interv ; 92(1): 141-148, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29130582

RESUMO

OBJECTIVES: The aim of this investigation was to identify patient's characteristics and periprocedural variables related to periprocedural transfusion in transfemoral Transcatheter Aortic Valve Implantation (tf-TAVI). BACKGROUND: Transfusion of allogenic red-blood cells (RBC) in tf-TAVI and the number of transfused units has been linked to an increased 30-day mortality. In line with the trend of minimization and cost-effectiveness, transfusion should be avoided, wherever possible. METHODS: Between 2007 and 2015, 1,734 procedures were analyzed from our prospective registry for RBC-transfusion. Multiple logistic regression analysis was used to identify the dependent variables. RESULTS: Transfusion was considered necessary in 14% (n = 243) of the patients. Female gender (OR [95% CI]) (1.680 [1.014-2.783]) and preprocedural moderate (7.594 [4.404-13.095]) and severe anemia (8.202 [0.900-74.752]) according to WHO were the most important preprocedural variables. Periprocedural, pericardial effusion (12.109 [3.753-39.063]), emergency extracorporeal circulation (54.5288 [6.178-481.259]) and major vascular injury (2.647 [1.412-4.962]) were related to transfusion. The same applies to moderate (4.255 [1.859-9.740]) and severe anemia (31.567 [8.560-116.416]) as well as periprocedural experience (0.072 [0.035-0.149] - 0.141[0.079-0.251], P < 0.001) CONCLUSION: Procedural experience, serious adverse events, low pre- and periprocedural Hb levels and female gender were the main variables relating to transfusion. Even in experienced high-volume centers, transfusion is still necessary in a considerable number of patients.


Assuntos
Anemia/terapia , Valva Aórtica/cirurgia , Cateterismo Periférico/métodos , Transfusão de Eritrócitos , Artéria Femoral , Doenças das Valvas Cardíacas/cirurgia , Assistência Perioperatória/métodos , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Anemia/sangue , Anemia/complicações , Anemia/diagnóstico , Biomarcadores/sangue , Cateterismo Periférico/efeitos adversos , Transfusão de Eritrócitos/efeitos adversos , Feminino , Doenças das Valvas Cardíacas/complicações , Doenças das Valvas Cardíacas/diagnóstico , Hemoglobinas/metabolismo , Humanos , Masculino , Assistência Perioperatória/efeitos adversos , Punções , Sistema de Registros , Fatores de Risco , Fatores Sexuais , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
7.
Catheter Cardiovasc Interv ; 92(1): 149-156, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29130616

RESUMO

BACKGROUND: Although the incidence of periprocedural complications has decreased in transcatheter aortic valve implantation (TAVI), life-threatening complications occur and emergency veno-arterial extracorporeal membrane oxygenation (vaECMO) can provide immediate circulatory stabilization. We report our two-center experience of vaECMO during life-threatening complications in TAVI. METHODS: From January 2010 to December 2015, 1,810 consecutive patients underwent TAVI at two centers. Clinical characteristics, type of complication, outcome and temporal trends in the requirement of emergency vaECMO were evaluated. RESULTS: Life-threatening complications requiring vaECMO occurred in 1.8% of cases (33 patients; 22 transfemoral, 11 transapical). Indications for vaECMO were ventricular rupture (30%, 10/33), low output (15%, 5/33), bleeding (12%, 4/33), coronary artery impairment (9%, 3/33), ventricular arrhythmias (6%, 2/33), severe aortic regurgitation (6%, 2/33), aortic annular rupture (6%, 2/33), and aortic dissection (3%, 1/33). In 4 cases, no definite cause for hemodynamic instability was identified. Conversion to open heart surgery was necessary in 42% of patients (14/33). Percutaneous coronary intervention was performed in all cases with coronary artery impairment (9%, 3/33). Patients with severe aortic regurgitation (6%, 2/33) underwent emergency valve-in-valve implantation. Other patients received, in addition to vaECMO support conservative treatment (42%, 14/33). In-hospital mortality and 30-day mortality were 46% (15/33). Of patients discharged, 67% (12/18) had no neurological impairment, whereas mild and severe neurological impairment was found in 11% (2/18) and 22% (4/18), respectively. From 2010 to 2015, with increasing procedures (from n = 43 to n = 553) requirement of vaECMO decreased from 9.3% to 0.9% (P for the trend <0.001). CONCLUSION: Over a 6-year period, need for emergency vaECMO during TAVI significantly decreased over time. Despite high in-hospital mortality, vaECMO represents a feasible strategy for hemodynamic support in case of life-threatening complications.


Assuntos
Valva Aórtica/cirurgia , Oxigenação por Membrana Extracorpórea , Doenças das Valvas Cardíacas/cirurgia , Complicações Pós-Operatórias/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Emergências , Oxigenação por Membrana Extracorpórea/efeitos adversos , Oxigenação por Membrana Extracorpórea/mortalidade , Feminino , Alemanha , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/mortalidade , Doenças das Valvas Cardíacas/fisiopatologia , Mortalidade Hospitalar , Humanos , Incidência , Masculino , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/mortalidade , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
8.
Biomarkers ; 23(3): 299-304, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29297708

RESUMO

PURPOSE: Elevated carbohydrate antigen 125 (CA125) predicts adverse outcome after transcatheter aortic valve implantation (TAVI). While known underlying pathophysiological mechanisms of elevated CA125 include serosal effusions and inflammatory stimuli, clinical determinants associated with elevated CA125 in patients referred for TAVI remain unknown. Therefore, we investigated clinical, laboratory and echocardiographic determinants of elevated CA125 in patients with severe aortic valve stenosis referred for TAVI. METHODS: This study includes 650 patients with severe aortic stenosis referred for TAVI. Baseline CA125 was determined by an immunoassay and dichotomized (elevated versus normal) based on the manufacturer cutoff value (>35 U/mL). RESULTS: CA125 elevation was present in 28% (181/650). Patients with elevated CA125 had an overall worse clinical profile and were more symptomatic with a higher rate of NYHA class III/IV (80% versus 58%; p < 0.001). In a multivariate analysis, independent predictors of elevated CA125 were New York Heart Association (NYHA) class, baseline hemoglobin, C-reactive protein (CRP), left ventricular ejection fraction and severe tricuspid regurgitation. CONCLUSION: Elevated CA125 levels in patients referred for TAVI summarize a subset of patients with an overall worse clinical profile who are more symptomatic.


Assuntos
Estenose da Valva Aórtica/sangue , Antígeno Ca-125/sangue , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/cirurgia , Proteína C-Reativa , Hemoglobinas , Humanos , Medição de Risco , Fatores de Risco , Insuficiência da Valva Tricúspide , Função Ventricular Esquerda
9.
Can J Anaesth ; 65(6): 647-657, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29464420

RESUMO

PURPOSE: Different sedation regimens have been described for use during transfemoral transcatheter aortic valve implantation (tf-TAVI) for treatment in patients with severe aortic stenosis. The purpose of this study was to compare dexmedetomidine (DEX) with a combination of propofol-opioid (PO) with respect to periprocedural gas exchange and hemodynamic support. METHODS: Data from a cohort of patients sedated with either DEX or PO for tf-TAVI were retrospectively analyzed from a prospectively maintained TAVI registry. Operative risk was determined from comorbidities and risk scores. Periprocedural partial pressure of carbon dioxide (PaCO2) was chosen as the primary endpoint. Other differences in gas exchange, need for catecholamine therapy, the frequency of conversion to general anesthesia, and need for sedative "rescue therapy" (in DEX patients) were secondary endpoints. Inverse probability of treatment weighting (IPTW) was used for analysis to minimize any selection bias. RESULTS: Of the 297 patients (140 PO, 157 DEX) included, the median [interquartile range] periprocedural PaCO2 values of DEX patients were significantly lower than in PO patients (40 [36-45] mmHg vs 44 [40-49] mmHg, respectively; median difference -4 mmHg; 95% confidence interval, -5 to -3 mmHg; P < 0.001). Hypercapnia (PaCO2 > 45 mmHg) was significantly less frequent in DEX patients compared with the PO group (25% vs 42%, respectively; P = 0.005). Vasopressor support was more frequent in the PO group compared with DEX (68% vs 25%, respectively; P < 0.001). Conversion to general anesthesia was not different between groups (9%, PO vs 3%, DEX; P = 0.051). Additional sedatives/opioids were required in 25 (16%) of the DEX patients. CONCLUSIONS: In sedated TAVI patients, DEX was associated with lower PaCO2 values and reduced requirements for vasopressor support, making it a promising alternative to PO for sedation during TAVI. TRIAL REGISTRATION: www.ClinicalTrials.gov (NCT01390675). Registered 11 July 2011.


Assuntos
Analgésicos Opioides , Sedação Consciente/métodos , Dexmedetomidina , Hipnóticos e Sedativos , Propofol , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Anestesia Geral , Estenose da Valva Aórtica/cirurgia , Dióxido de Carbono/sangue , Estudos de Coortes , Determinação de Ponto Final , Feminino , Hemodinâmica , Humanos , Masculino , Troca Gasosa Pulmonar , Estudos Retrospectivos , Medição de Risco
10.
Clin Res Cardiol ; 113(2): 276-287, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37870627

RESUMO

OBJECTIVES: Systemic inflammatory response syndrome (SIRS) is a common finding after cardiovascular interventions. Data on the incidence of SIRS and its impact on outcome in patients undergoing transcatheter edge-to-edge mitral valve repair (MV-TEER) for mitral regurgitation (MR) is lacking. METHODS: From January 2013 to December 2020, 373 patients with moderate or severe MR undergoing MV-TEER were included. SIRS was defined as at least two of the following criteria within 48 h after the procedure: leucocyte count > 12.0 or < 4.0 × 109/l, respiratory rate > 20 breaths per minute or PaCO2 ≤ 4.3 kPa/32 mmHg, heart rate > 90 bpm and temperature > 38.0 °C or < 36.0 °C. The primary endpoint was 3-years all-cause mortality. RESULTS: SIRS was observed in 49.6% (185/373) of patients. Patients who developed SIRS presented more frequently with NYHA III/IV at baseline [SIRS: 82.4% (149/185) vs. no SIRS: 79.0% (147/188); p = 0.029]. Patients who developed SIRS spent more days on ICU (p < 0.001) and overall length of stay was longer (p < 0.001). Relevant residual MR, defined as MR ≥ III in-hospital, was present more often in patients who developed SIRS [SIRS: 11.3% (20/177) vs. no SIRS: 3.93% (7/178), p = 0.036]. At 3 years, all-cause mortality in the entire population was 33.5% (125/373) with an increased all-cause mortality in patients with SIRS compared to patients without SIRS (HR 1.49, [CI 95% 1.04, 2.13]; p = 0.0264). In the multivariate analysis development of SIRS (HR 1.479 [CI 95% 1.016, 2.154]; p = 0.041) was identified as predictor for 3-years all-cause mortality. CONCLUSIONS: SIRS is a common finding after MV-TEER occurring in approximately half of patients. SIRS after MV-TEER was associated with a longer in-hospital stay. In addition, we observed an increased 3-years all-cause mortality in patients with SIRS.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Incidência , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Síndrome de Resposta Inflamatória Sistêmica/diagnóstico , Síndrome de Resposta Inflamatória Sistêmica/epidemiologia , Síndrome de Resposta Inflamatória Sistêmica/etiologia , Frequência Cardíaca , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/epidemiologia , Insuficiência da Valva Mitral/cirurgia , Resultado do Tratamento , Implante de Prótese de Valva Cardíaca/efeitos adversos
11.
Artigo em Inglês | MEDLINE | ID: mdl-38065713

RESUMO

BACKGROUND: Data on systemic inflammatory response syndrome (SIRS) after transcatheter aortic valve implantation (TAVI) are scarce and limited to small cohorts. We aimed to investigate its incidence and mid-term impact in a large cohort of TAVI patients. METHODS: From January 2018 to December 2020, 717 patients with severe aortic valve stenosis undergoing TAVI were included. SIRS was defined as fulfilling at least two of the following criteria within 48 h from the procedure: leucocyte count >12.0 or <4.0 × 109/l, respiratory rate > 20 breaths per minute or PaCO2 ≤ 4.3 kPa/32 mmHg, heart rate > 90 beats per minute and temperature > 38.0 °C or <36.0 °C. Clinical endpoints were 1-year rehospitalization for chronic heart failure (CHF) and 2-years all-cause mortality. Event rates during follow-up were calculated as Kaplan-Meier estimates. RESULTS: SIRS developed in 56.3 % (404/717) of patients after TAVI. SIRS occurred more frequently in patients with post-dilatation (SIRS 34.7 % (140/404) vs. no SIRS 23.3 % (73/313); p < 0.001) and major vascular complications (SIRS 16.1 % (65/404) vs. no SIRS 8.6 % (27/313); p = 0.004). Further, ICU days were more in patients who developed SIRS (SIRS 1.56 ± 1.50 days vs. no SIRS 1.22 ± 1.02 days; p = 0.001). At 2-years, all-cause mortality in the entire population was 23.9 %. However, there was no difference in CHF at 1-year (5.9 % vs. 4.1 %; log-rank = 0.347) nor in all-cause mortality at 2-years (22.0 % vs. 26.2 %; log-rank = 0.690) between the groups. CONCLUSIONS: SIRS is a common finding after TAVI, which may prolong hospital stay but is without effect on mortality during 2-years follow-up.

12.
Eur Heart J Cardiovasc Imaging ; 24(5): 574-587, 2023 04 24.
Artigo em Inglês | MEDLINE | ID: mdl-36735333

RESUMO

AIMS: Patients with mitral regurgitation (MR) present with considerable heterogeneity in cardiac damage depending on underlying aetiology, disease progression, and comorbidities. This study aims to capture their cardiopulmonary complexity by employing a machine-learning (ML)-based phenotyping approach. METHODS AND RESULTS: Data were obtained from 1426 patients undergoing mitral valve transcatheter edge-to-edge repair (MV TEER) for MR. The ML model was developed using 609 patients (derivation cohort) and validated on 817 patients from two external institutions. Phenotyping was based on echocardiographic data, and ML-derived phenotypes were correlated with 5-year outcomes. Unsupervised agglomerative clustering revealed four phenotypes among the derivation cohort: Cluster 1 showed preserved left ventricular ejection fraction (LVEF; 56.5 ± 7.79%) and regular left ventricular end-systolic diameter (LVESD; 35.2 ± 7.52 mm); 5-year survival in Cluster 1, hereinafter serving as a reference, was 60.9%. Cluster 2 presented with preserved LVEF (55.7 ± 7.82%) but showed the largest mitral valve effective regurgitant orifice area (0.623 ± 0.360 cm2) and highest systolic pulmonary artery pressures (68.4 ± 16.2 mmHg); 5-year survival ranged at 43.7% (P-value: 0.032). Cluster 3 was characterized by impaired LVEF (31.0 ± 10.4%) and enlarged LVESD (53.2 ± 10.9 mm); 5-year survival was reduced to 38.3% (P-value: <0.001). The poorest 5-year survival (23.8%; P-value: <0.001) was observed in Cluster 4 with biatrial dilatation (left atrial volume: 312 ± 113 mL; right atrial area: 46.0 ± 8.83 cm2) although LVEF was only slightly reduced (51.5 ± 11.0%). Importantly, the prognostic significance of ML-derived phenotypes was externally confirmed. CONCLUSION: ML-enabled phenotyping captures the complexity of extra-mitral valve cardiac damage, which does not necessarily occur in a sequential fashion. This novel phenotyping approach can refine risk stratification in patients undergoing MV TEER in the future.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Insuficiência da Valva Mitral/cirurgia , Função Ventricular Esquerda , Volume Sistólico , Resultado do Tratamento , Estudos Retrospectivos , Fenótipo , Implante de Prótese de Valva Cardíaca/efeitos adversos
13.
Front Cardiovasc Med ; 9: 1039208, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36531697

RESUMO

Aims: To quantify extra-valvular cardiac damage associated with severe aortic valve stenosis (AS), a novel staging model was proposed. This study aimed to validate this model in patients undergoing transcatheter aortic valve replacement (TAVR) as well as to assess its prognostic impact. Methods and results: Based on echocardiographic findings, the following stages were applied: isolated AS (stage 0), left ventricular (LV) damage (stage 1), left atrial or mitral valve damage (stage 2), pulmonary hypertension or tricuspid regurgitation (stage 3), or right ventricular dysfunction (stage 4). The primary endpoint was 2-year all-cause mortality. The distribution across stages was 0.8% at stage 0, 7.5% at stage 1, 63.3% at stage 2, 18.3% at stage 3, and 10.1% at stage 4. All-cause mortality increased at all stages 1-4 (12.1%, 18.2%, 26.6%, and 28.2%; p = 0.023). In the multivariate model, the stage of cardiac damage, age, New York Heart Association (NYHA) class III/IV, peripheral artery disease, and previous pacemaker were independent predictors of the primary endpoint. Conclusions: Patients treated for severe AS show a high prevalence of extra-valvular cardiac damage. An increase in stage is associated with higher 2-year all-cause mortality. The application of this staging model may add value to current treatment algorithms.

14.
Clin Res Cardiol ; 111(1): 14-22, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33367949

RESUMO

AIMS: To investigate the clinical outcomes associated with an antithrombotic therapy with or without clopidogrel after transcatheter aortic valve replacement (TAVR). METHODS AND RESULTS: This is a study-level meta-analysis including all randomized trials investigating antithrombotic regimens after TAVR. The protocol was registered with PROSPERO (CRD42020191036). We searched electronic scientific databases for eligible studies. The primary outcome was all-cause death. Main secondary outcome was major bleeding. Other outcomes were life-threatening (or disabling) bleeding, myocardial infarction (MI) and stroke. Six eligible trials randomly allocated 3056 TAVR patients to aspirin or oral anticoagulation (OAC) with clopidogrel (n = 1525) versus aspirin and/or OAC without clopidogrel (n = 1531). In the overall estimates, an antithrombotic therapy with clopidogrel versus without displayed a comparable risk of all-cause death [Risk Ratio-RR = 0.83, 95% Confidence intervals-CI (0.57-1.20); P = 0.25] and major bleeding [RR = 1.33, 95% CI (0.61-2.92); P = 0.39]. However, the combination of aspirin or OAC with clopidogrel doubled the risk of major bleeding as compared to aspirin or OAC without clopidogrel [RR = 2.08, 95% CI (1.27-3.42); P = 0.015, P for interaction = 0.021]. Treatment strategies did not differ with respect to the risk of life-threatening bleeding, MI and stroke. CONCLUSIONS: In patients receiving TAVR, a therapeutic strategy of aspirin or OAC with clopidogrel significantly increases the risk of major bleeding without impact on mortality and ischemic outcomes compared to aspirin or OAC without clopidogrel. The performance of different antithrombotic regimens in terms of long-term clinical outcomes and bioprosthesis valve function requires further investigation. Forest plots from pairwise and network meta-analyses associated with an antithrombotic therapy with or without clopidogrel Risk ratio for all outcomes of interest calculated with the pairwise meta-analysis (left side) and for main outcomes calculated with the network meta-analysis (right side) in patients allocated to an antithrombotic therapy with clopidogrel or without. The diamonds indicate the point estimate and the left and the right ends of the lines the [95% CI]. CI: Confidence intervals; OAC; oral anticoagulation.


Assuntos
Aspirina/administração & dosagem , Clopidogrel/administração & dosagem , Fibrinolíticos/administração & dosagem , Inibidores da Agregação Plaquetária/administração & dosagem , Complicações Pós-Operatórias/prevenção & controle , Substituição da Valva Aórtica Transcateter , Quimioterapia Combinada , Humanos , Ensaios Clínicos Controlados Aleatórios como Assunto
15.
Int J Cardiol ; 357: 115-120, 2022 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-35337936

RESUMO

BACKGROUND: Direct comparisons of latest-generation balloon-expandable versus self-expanding transcatheter heart valves (THV) are scarce. To compare outcomes after transcatheter aortic valve replacement (TAVR) with SAPIEN 3 Ultra (Ultra) versus Evolut R or Pro (Evolut) THVs. METHODS: 1612 consecutive patients undergoing TAVR with either Ultra (n = 616) or Evolut (n = 996) were included. After propensity score matching (PSM), 467 and 205 matched pairs were identified in the entire cohort and with latest-generation THVs, respectively. Outcomes were investigated up to 30 days after TAVR. RESULTS: After PSM, baseline characteristics were comparable in the entire cohort (n = 934). Device success (92.7% vs. 87.6%; p = 0.011) and need for permanent pacemaker implantation (PPI) (15.2% vs. 8.4%; p = 0.002) were higher for Evolut compared with Ultra. Elevated gradients (≥20 mm Hg) were less frequent (1.6% vs. 10.4%; p < 0.001), whereas rates of ≥ moderate paravalvular leakage (PVL II+) were more frequent for Evolut compared with Ultra (3.7% vs. 1.3%; p = 0.019). With latest-generation THVs (n = 410), device success was comparable (93.2% vs. 89.8%; p = 0.216), whereas the need for PPI was higher for Evolut Pro compared with Ultra (15.6% vs. 9.8%; p = 0.075). Elevated gradients were less frequent (0% vs. 8%; p < 0.001), whereas rates of PVL II+ were more frequent for Evolut compared with Ultra (5.4% vs. 1.5%; p = 0.028). CONCLUSIONS: Device success rates were high with both THV platforms with low rates of adverse events up to 30 days after TAVR. Compared with Ultra, Evolut was associated with higher pacemaker rates as well as PVL II+, but with less elevated gradients.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/etiologia , Estenose da Valva Aórtica/cirurgia , Humanos , Desenho de Prótese , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
17.
Am J Cardiol ; 138: 92-99, 2021 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-33065085

RESUMO

Bioprosthetic valve thrombosis may complicate transcatheter aortic valve implantation (TAVI). This meta-analysis sought to evaluate the prevalence and clinical impact of subclinical leaflet thrombosis (SLT) and clinical valve thrombosis (CVT) after TAVI. We summarized diagnostic strategies, prevalence of SLT and/or CVT and estimated their impact on the risk of all-cause death and stroke. Twenty studies with 12,128 patients were included. The prevalence of SLT and CVT was 15.1% and 1.2%, respectively. The risk of all-cause death was not significantly different between patients with SLT (relative risk [RR] 0.77; p = 0.22) and CVT (RR 1.29; p = 0.68) compared with patients without. The risk of stroke was higher in patients with CVT (RR 7.51; p <0.001) as compared with patients without, while patients with SLT showed no significant increase in the risk of stroke (RR 1.81; p = 0.17). Reduced left ventricular function was associated with increased prevalence, while oral anticoagulation was associated with reduced prevalence of bioprosthetic valve thrombosis. Bioprosthetic valve thrombosis is frequent after TAVI, but does not increase the risk of death. Clinical valve thrombosis is associated with a significantly increased risk of stroke. Future studies should focus on prevention and treatment of bioprosthetic valve thrombosis.


Assuntos
Estenose da Valva Aórtica/cirurgia , Bioprótese , Próteses Valvulares Cardíacas , Complicações Pós-Operatórias/epidemiologia , Trombose/epidemiologia , Substituição da Valva Aórtica Transcateter , Anticoagulantes/uso terapêutico , Doenças Assintomáticas/epidemiologia , Causas de Morte , Humanos , Mortalidade , Complicações Pós-Operatórias/fisiopatologia , Prevalência , Fatores de Proteção , Risco , Fatores de Risco , Acidente Vascular Cerebral/epidemiologia , Trombose/fisiopatologia , Disfunção Ventricular Esquerda/epidemiologia
18.
Am J Cardiol ; 139: 71-78, 2021 01 15.
Artigo em Inglês | MEDLINE | ID: mdl-33190811

RESUMO

We aimed to evaluate the efficacy and safety of a low-dose imaging protocol to reduce intraprocedural radiation during transcatheter aortic valve implantation (TAVI). Observational analysis: 802 transfemoral TAVI patients receiving balloon-expandable devices ≥23 mm at a high-volume centre. After propensity score matching, a standard-dose group (SD, n = 333) treated between January 2014 and February 2016 was compared with a low-dose group (LD, n = 333) treated between August 2017 and March 2019 after departmental uptake of a low-dose imaging protocol (reduced field size, high table height, use of "fluoro save," 3.75 frames/second acquisition, increased filtering). Primary end point was dose-area product (DAP). Secondary safety end points were VARC-2 device success and a composite of in-hospital complications. The LD protocol was associated with lower DAP (4.64 [2.93, 8.42] vs 22.73 [12.31, 34.58] Gy⋅cm2, p <0.001) and fluoroscopy time (10.4 [8.1, 13.9] vs 11.5 [9.1, 15.3] minutes, p = 0.001). Contrast use was higher in the LD group (LD 110 [94, 130] vs SD 100 [80, 135] milliliters, p = 0.042). Device success (LD 88.3% vs SD 91.3%, p = 0.25), and the composite end point (LD 8.1% vs SD 11.4%, p = 0.19) were similar. In multivariate analysis, the low-dose protocol was associated with a 19.8 Gy⋅cm2 reduction in procedural DAP (p <0.001). In conclusion, compared with standard imaging, a low-dose protocol for TAVI significantly reduced radiation dose without compromising outcomes.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Fluoroscopia/métodos , Lesões por Radiação/prevenção & controle , Cirurgia Assistida por Computador/métodos , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico , Relação Dose-Resposta à Radiação , Feminino , Humanos , Masculino , Prognóstico , Estudos Retrospectivos , Fatores de Risco
19.
Clin Res Cardiol ; 110(12): 1993-2006, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34505192

RESUMO

BACKGROUND: Bicuspid aortic valve may be associated with increased complications during transcatheter aortic valve implantation (TAVI). AIMS: Compare balloon-expandable transcatheter heart valve (THV) safety and efficacy in severe tricuspid (TAV) and bicuspid (BAV) aortic stenosis. METHODS: Transfemoral TAVI was performed in 743 patients (Jan 2014-June 2019) using the SAPIEN 3 THV. Aortic valve morphology was determined using computed tomography. Valve Academic Research Consortium-2 (VARC-2) derived safety and efficacy endpoints at 1 year were evaluated. RESULTS: BAV patients (n = 78), were younger (77 [72, 81] vs. 81 [78, 85] years, p < 0.001) with lower surgical risk (EuroSCORE II 2.96% vs. 4.51% p < 0.001). Bicuspid valves were more calcified (BAV 1308mm3, TAV 848mm3 p < 0.001) with more asymmetric calcification (BAV 63/78 (81%), TAV 239/665 (36%), p < 0.001). Device success (BAV 94%, TAV 90%, p = 0.45) and major vascular complications (BAV 6%, TAV 9%, p = 0.66) were comparable. At 1 year, there was a trend toward lower combined all-cause mortality and rehospitalization for congestive heart failure in BAV patients (BAV 7%, TAV 13%, p = 0.08) with significantly lower all-cause mortality in this cohort (BAV 1%, TAV 9%, p = 0.020). VARC-2 time-related valve safety (BAV 22%, TAV 20%, p = 0.60) was comparable; however, bioprosthetic valve thrombosis remained more common in BAV patients (BAV 7%, TAV 2%, p = 0.010, Hazard ratio 3.57 [95% confidence interval 1.26, 10.10]). After propensity score matching, only bioprosthetic valve thrombosis remained significantly different. CONCLUSIONS: Safety and efficacy of the SAPIEN 3 balloon-expandable THV in BAV is comparable with TAV. Higher rates of bioprosthetic valve thrombosis require further investigation.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/métodos , Valva Tricúspide/cirurgia , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico , Feminino , Seguimentos , Humanos , Masculino , Tomografia Computadorizada Multidetectores/métodos , Desenho de Prótese , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
20.
J Thorac Dis ; 12(11): 6769-6779, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33282378

RESUMO

BACKGROUND: This study compares two latest-generation self-expanding transcatheter heart valves (THV), the supra-annular ACURATE neo (Boston Scientific) and the intra-annular Centera THV (Edwards Lifesciences). METHODS: In this single center observational cohort trial 317 patients treated with the ACURATE neo and 78 patients treated with the Centera TVH were included. The main endpoints were device success and the early safety endpoint at 30 days. RESULTS: Besides higher incidence of diabetes mellitus and higher body mass index in patients treated with the ACURATE neo THV, there were no baseline differences between the groups. Device success was similar in both groups (neo: 91.8% vs. Centera: 93.6%; P=0.598), with numerically higher rates of moderate to severe paravalvular leakage in the ACURATE neo group (4.7% vs. 1.3%; P=0.214). At 30 days all-cause mortality rates were low in both groups (0.3% vs. 0%; P=0.620) and no difference occurred in the early safety at 30 days (19.3% vs. 16.7%; P=0.599). However, all-cause stroke rates were significantly higher in patients treated with the Centera THV (6.4 vs. 1.6%; P=0.015). CONCLUSIONS: The ACURATE neo and the Centera THV show low mortality rates as well as comparable, favorable hemodynamics. The finding of higher stroke rates at 30 days with the repositionable Centera SE-THV needs further assessment.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA