Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Med Phys ; 39(4): 1811-7, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22482603

RESUMO

PURPOSE: In prostate brachytherapy, accurate positioning of the needle tip to place radioactive seeds at its target site is critical for successful radiation treatment. During the procedure, needle deflection leads to seed misplacement and suboptimal radiation dose to cancerous cells. In practice, radiation oncologists commonly use high-speed hand needle insertion to minimize displacement of the prostate as well as the needle deflection. Effects of speed during needle insertion and stiffness of trocar (a solid rod inside the hollow cannula) on needle deflection are studied. METHODS: Needle insertion experiments into phantom were performed using a 2(2) factorial design (2 parameters at 2 levels), with each condition having replicates. Analysis of the deflection data included calculating the average, standard deviation, and analysis of variance (ANOVA) to find significant single and two-way interaction factors. RESULTS: The stiffer tungsten carbide trocar is effective in reducing the average and standard deviation of needle deflection. The fast insertion speed together with the stiffer trocar generated the smallest average and standard deviation for needle deflection for almost all cases. CONCLUSIONS: The combination of stiff tungsten carbide trocar and fast needle insertion speed are important to decreasing needle deflection. The knowledge gained from this study can be used to improve the accuracy of needle insertion during brachytherapy procedures.


Assuntos
Braquiterapia/instrumentação , Agulhas , Neoplasias da Próstata/fisiopatologia , Neoplasias da Próstata/radioterapia , Implantação de Prótese/métodos , Braquiterapia/métodos , Módulo de Elasticidade , Análise de Falha de Equipamento , Humanos , Masculino , Neoplasias da Próstata/cirurgia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
Med Phys ; 38(8): 4749-59, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21928648

RESUMO

PURPOSE: In prostate brachytherapy, a grid is used to guide a needle tip toward a preplanned location within the tissue. During insertion, the needle deflects en route resulting in target misplacement. In this paper, 18-gauge needle insertion experiments into phantom were performed to test effects of three parameters, which include the clearance between the grid hole and needle, the thickness of the grid, and the needle insertion speed. Measurement apparatus that consisted of two datum surfaces and digital depth gauge was developed to quantify needle deflections. METHODS: The gauge repeatability and reproducibility (GR&R) test was performed on the measurement apparatus, and it proved to be capable of measuring a 2 mm tolerance from the target. Replicated experiments were performed on a 2(3) factorial design (three parameters at two levels) and analysis included averages and standard deviation along with an analysis of variance (ANOVA) to find significant single and two-way interaction factors. RESULTS: Results showed that grid with tight clearance hole and slow needle speed increased precision and accuracy of needle insertion. The tight grid was vital to enhance precision and accuracy of needle insertion for both slow and fast insertion speed; additionally, at slow speed the tight, thick grid improved needle precision and accuracy. CONCLUSIONS: In summary, the tight grid is important, regardless of speed. The grid design, which shows the capability to reduce the needle deflection in brachytherapy procedures, can potentially be implemented in the brachytherapy procedure.


Assuntos
Braquiterapia/instrumentação , Braquiterapia/métodos , Braquiterapia/estatística & dados numéricos , Desenho de Equipamento , Mãos , Humanos , Masculino , Movimento , Agulhas , Imagens de Fantasmas , Projetos Piloto , Neoplasias da Próstata/radioterapia , Distribuição Aleatória , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA