Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Europace ; 25(5)2023 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-37125968

RESUMO

AIMS: Pulmonary vein (PV) antrum isolation proved to be effective for treating persistent atrial fibrillation (PeAF). We sought to investigate the results of a personalized approach aimed at adapting the ablation index (AI) to the local left atrial wall thickness (LAWT) in a cohort of consecutive patients with PeAF. METHODS AND RESULTS: Consecutive patients referred for PeAF first ablation were prospectively enrolled. The LAWT three-dimensional maps were obtained from pre-procedure multidetector computed tomography and integrated into the navigation system. Ablation index was titrated according to the local LAWT, and the ablation line was personalized to avoid the thickest regions while encircling the PV antrum. A total of 121 patients (69.4% male, age 64.5 ± 9.5 years) were included. Procedure time was 57 min (IQR 50-67), fluoroscopy time was 43 s (IQR 20-71), and radiofrequency (RF) time was 16.5 min (IQR 14.3-18.4). The median AI tailored to the local LAWT was 387 (IQR 360-410) for the anterior wall and 335 (IQR 300-375) for the posterior wall. First-pass PV antrum isolation was obtained in 103 (85%) of the right PVs and 103 (85%) of the left PVs. Median LAWT values were higher for PVs without first-pass isolation as compared to the whole cohort (P = 0.02 for left PVs and P = 0.03 for right PVs). Recurrence-free survival was 79% at 12 month follow-up. CONCLUSION: In this prospective study, LAWT-guided PV antrum isolation for PeAF was effective and efficient, requiring low procedure, fluoroscopy, and RF time. A randomized trial comparing the LAWT-guided ablation with the standard of practice is in progress (ClinicalTrials.gov, NCT05396534).


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Estudos Prospectivos , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Resultado do Tratamento
2.
J Interv Card Electrophysiol ; 66(1): 39-47, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36227461

RESUMO

BACKGROUND: Recent studies showed that an early strategy for ventricular tachycardia (VT) ablation resulted in reduction of VT episodes or mortality. Cardiac magnetic resonance (CMR)-derived border zone channel (BZC) mass has proved to be a strong non-invasive predictor of VT in post-myocardial infarction (MI). CMR-guided VT substrate ablation proved to be safe and effective for reducing sudden cardiac death (SCD) and VA occurrence. METHODS: PREVENT-VT is a prospective, randomized, multicenter, and controlled trial designed to evaluate the safety and efficacy of prophylactic CMR-guided VT substrate ablation in chronic post-MI patients with CMR-derived arrhythmogenic scar characteristics. Chronic post-MI patients with late gadolinium enhancement (LGE) CMR will be evaluated. CMR images will be post-processed and the BZC mass measured: patients with a BZC mass > 5.15 g will be eligible. Consecutive patients will be enrolled at 3 centers and randomized on a 1:1 basis to undergo a VT substrate ablation (ABLATE arm) or optimal medical treatment (OMT arm). Primary prevention ICD will be implanted following guideline recommendations, while non-ICD candidates will be implanted with an implantable cardiac monitor (ICM). The primary endpoint is a composite outcome of sudden cardiac death (SCD) or sustained monomorphic VT, either treated by an ICD or documented with ICM. Secondary endpoints are procedural safety and efficiency outcomes of CMR-guided ablation. DISCUSSION: In some patients, the first VA episode causes SCD or severe neurological damage. The aim of the PREVENT-VT is to evaluate whether primary preventive substrate ablation may be a safe and effective prophylactic therapy for reducing SCD and VA occurrence in patients with previous MI and high-risk scar characteristics based on CMR. TRIAL REGISTRATION: ClinicalTrials.gov, NCT04675073, registered on January 1, 2021.


Assuntos
Ablação por Cateter , Infarto do Miocárdio , Taquicardia Ventricular , Humanos , Meios de Contraste , Estudos Prospectivos , Cicatriz/diagnóstico por imagem , Cicatriz/cirurgia , Cicatriz/etiologia , Gadolínio , Arritmias Cardíacas/cirurgia , Infarto do Miocárdio/complicações , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/cirurgia , Taquicardia Ventricular/prevenção & controle , Taquicardia Ventricular/cirurgia , Taquicardia Ventricular/etiologia , Morte Súbita Cardíaca/prevenção & controle , Morte Súbita Cardíaca/etiologia , Ablação por Cateter/métodos
3.
J Interv Card Electrophysiol ; 66(9): 1979-1988, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36877415

RESUMO

BACKGROUND: Catheter ablation is recommended as first-line therapy for patients with symptomatic typical AFl. Although the conventional multi-catheter approach is the standard of care for cavotricuspid isthmus (CTI) ablation, a single-catheter approach was recently described as a feasible alternative. The present study sought to compare safety, efficacy, and efficiency of single vs. multi-catheter approach for atrial flutter (AFl) ablation. METHODS: In this randomized multi-center study, consecutive patients referred for AFl ablation (n = 253) were enrolled and randomized to multiple vs. single-catheter approach for CTI ablation. In the single-catheter arm, PR interval (PRI) on the surface ECG was used to prove CTI block. Procedural and follow-up data were collected and compared between the two arms. RESULTS: 128 and 125 patients were assigned to the single-catheter and to the multi-catheter arms, respectively. In the single-catheter arm, procedure time was significantly shorter (37 ± 25 vs. 48 ± 27 minutes, p = 0.002) and required less fluoroscopy time (430 ± 461 vs. 712 ± 628 seconds, p < 0.001) and less radiofrequency time (428 ± 316 vs. 643 ± 519 seconds, p < 0.001), achieving a higher first-pass CTI block rate (55 (45%) vs. 37 (31%), p = 0.044), compared with the multi-catheter arm. After a median follow-up of 12 months, 11 (4%) patients experienced AFl recurrences (5 (4%) in the single-catheter arm and 6 (5%) in the multi-catheter arm, p = 0.99). No differences were found in arrhythmia-free survival between arms (log-rank = 0.71). CONCLUSIONS: The single-catheter approach for typical AFl ablation is not inferior to the conventional multiple-catheter approach, reducing procedure, fluoroscopy, and radiofrequency time.


Assuntos
Flutter Atrial , Ablação por Cateter , Humanos , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Flutter Atrial/cirurgia , Ablação por Cateter/métodos , Catéteres
4.
J Interv Card Electrophysiol ; 66(8): 1877-1888, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36795268

RESUMO

BACKGROUND: To predict the outflow tract ventricular arrhythmias (OTVA) site of origin (SOO) before the ablation procedure has important practical implications. The present study sought to prospectively evaluate the accuracy of a clinical and electrocardiographic hybrid algorithm (HA) for the prediction of OTVAs-SOO, and at the same time to develop and to prospectively validate a new score with improved discriminatory capacity. METHODS: In this multicenter study, we prospectively enrolled consecutive patients referred for OTVA ablation (N = 202), and we divided them in a derivation sample and a validation cohort. Surface ECGs during OTVA were analyzed to compare previous published ECG-only criteria and to develop a new score. RESULTS: In the derivation sample (N = 105), the correct prediction rate of HA and ECG-only criteria ranged from 74 to 89%. R-wave amplitude in V3 was the best ECG parameter for discriminating LVOT origin in V3 precordial transition (V3PT) patients, and was incorporated to the novel weighted hybrid score (WHS). WHS correctly classified 99 (94.2%) patients, presenting 90% sensitivity and 96% specificity (AUC 0.97) in the entire population; WHS mantained a 87% sensitivity and 91% specificity (AUC 0.95) in patients with V3PT subgroup. The high discriminatory capacity was confirmed in the validation sample (N = 97): the WHS exhibited an AUC (0.93), and a WHS ≥ 2 allowed a correct prediction of LVOT origin in 87 (90.0%) cases, yielding a sensitivity of 87% and specificity of 90%; moreover, the V3PT subgroup showed an AUC of 0.92, and a punctuation ≥ 2 predicted an LVOT origin with a sensitivity of 94% and specificity of 78%. CONCLUSIONS: The novel hybrid score has proved to accurately anticipate the OTVA's origin, even in those with a V3 precordial transition. A Weighted hybrid score. B Typical examples of the use of the weighted hybrid score. C ROC analysis of WHS and previous ECG criteria for prediction of LVOT origin in the derivation cohort. D ROC analysis of WHS and previous ECG criteria for prediction of LVOT origin in the V3 precordial transition OTVA subgroup.

5.
J Interv Card Electrophysiol ; 65(3): 651-661, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35861901

RESUMO

BACKGROUND: Pulmonary vein isolation (PVI) implies unavoidable ablation lesions to the left atrial posterior wall, which is closely related to the esophagus, leading to several potential complications. This study evaluates the usefulness of the esophageal fingerprint in avoiding temperature rises during paroxysmal atrial fibrillation (PAF) ablation. METHODS: Isodistance maps of the atrio-esophageal relationship (esophageal fingerprint) were derived from the preprocedural computerized tomography. Patients were randomized (1:1) into two groups: (1) PRINT group, the PVI line was modified according to the esophageal fingerprint; (2) CONTROL group, standard PVI with operator blinded to the fingerprint. The primary endpoint was temperature rise detected by intraluminal esophageal temperature probe monitoring. Ablation settings were as specified on the Ablate BY-LAW study protocol. RESULTS: Sixty consecutive patients referred for paroxysmal AF ablation were randomized (42 (70%) men, mean age 60 ± 11 years). Temperature rise (> 39.1 °C) occurred in 5 (16%) patients in the PRINT group vs. 17 (56%) in the CONTROL group (p < 0.01). Three AF recurrences were documented at a mean follow-up of 12 ± 3 months (one (3%) in the PRINT group and 2 (6.6%) in the CONTROL group, p = 0.4). CONCLUSION: The esophageal fingerprint allows for a reliable identification of the esophageal position and its use for PVI line deployment results in less frequent esophageal temperature rises when compared to the standard approach. Further studies are needed to evaluate the impact of PVI line modification to avoid esophageal heating on long-term outcomes. The development of new imaging-derived tools could ultimately improve patient safety (NCT04394923).


Assuntos
Fibrilação Atrial , Idoso , Humanos , Pessoa de Meia-Idade , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA