Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 41
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Magn Reson Med ; 92(3): 1138-1148, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38730565

RESUMO

PURPOSE: To develop a highly accelerated multi-echo spin-echo method, TEMPURA, for reducing the acquisition time and/or increasing spatial resolution for kidney T2 mapping. METHODS: TEMPURA merges several adjacent echoes into one k-space by either combining independent echoes or sharing one echo between k-spaces. The combined k-space is reconstructed based on compressed sensing theory. Reduced flip angles are used for the refocusing pulses, and the extended phase graph algorithm is used to correct the effects of indirect echoes. Two sequences were developed: a fast breath-hold sequence; and a high-resolution sequence. The performance was evaluated prospectively on a phantom, 16 healthy subjects, and two patients with different types of renal tumors. RESULTS: The fast TEMPURA method reduced the acquisition time from 3-5 min to one breath-hold (18 s). Phantom measurements showed that fast TEMPURA had a mean absolute percentage error (MAPE) of 8.2%, which was comparable to a standardized respiratory-triggered sequence (7.4%), but much lower than a sequence accelerated by purely k-t undersampling (21.8%). High-resolution TEMPURA reduced the in-plane voxel size from 3 × 3 to 1 × 1 mm2, resulting in improved visualization of the detailed anatomical structure. In vivo T2 measurements demonstrated good agreement (fast: MAPE = 1.3%-2.5%; high-resolution: MAPE = 2.8%-3.3%) and high correlation coefficients (fast: R = 0.85-0.98; high-resolution: 0.82-0.96) with the standardized method, outperforming k-t undersampling alone (MAPE = 3.3-4.5%, R = 0.57-0.59). CONCLUSION: TEMPURA provides fast and high-resolution renal T2 measurements. It has the potential to improve clinical throughput and delineate intratumoral heterogeneity and tissue habitats at unprecedented spatial resolution.


Assuntos
Algoritmos , Neoplasias Renais , Rim , Imagens de Fantasmas , Humanos , Neoplasias Renais/diagnóstico por imagem , Rim/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Feminino , Adulto , Masculino , Interpretação de Imagem Assistida por Computador/métodos , Reprodutibilidade dos Testes , Pessoa de Meia-Idade , Aumento da Imagem/métodos , Processamento de Imagem Assistida por Computador/métodos , Suspensão da Respiração
2.
J Magn Reson Imaging ; 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38380700

RESUMO

BACKGROUND: T2 mapping is valuable to evaluate pathophysiology in kidney disease. However, variations in T2 relaxation time measurements across MR scanners and vendors may occur requiring additional correction. PURPOSE: To harmonize renal T2 measurements between MR vendor platforms, and use an extended-phase-graph-based fitting method ("StimFit") to correct stimulated echoes and reduce between-vendor variations. STUDY TYPE: Prospective. SUBJECTS: 8 healthy "travelling" volunteers (37.5% female, 32 ± 6 years) imaged on four MRI systems across three vendors at four sites, 10 healthy volunteers (50% female, 32 ± 8 years) scanned multiple times on a given MR scanner for repeatability evaluation. ISMRM/NIST system phantom scanned for evaluation of T2 accuracy. FIELD STRENGTH/SEQUENCE: 3T, multiecho spin-echo sequence. ASSESSMENT: T2 images fit using conventional monoexponential fitting and "StimFit." Mean absolute percentage error (MAPE) of phantom measurements with reference T2 values. Average cortex and medulla T2 values compared between MR vendors, with masks obtained from T2 -weighted images and T1 maps. Full-width-at-half-maximum (FWHM) T2 distributions to evaluate local homogeneity of measurements. STATISTICAL TESTS: Coefficient of variation (CV), linear mixed-effects model, analysis of variance, student's t-tests, Bland-Altman plots, P-value <0.05 considered statistically significant. RESULTS: In the ISMRM/NIST phantom, "StimFit" reduced the MAPE from 4.9%, 9.1%, 24.4%, and 18.1% for the four sites (three vendors) to 3.3%, 3.0%, 6.6%, and 4.1%, respectively. In vivo, there was a significant difference in kidney T2 measurements between vendors using a monoexponential fit, but not with "StimFit" (P = 0.86 and 0.92, cortex and medulla, respectively). The intervendor CVs of T2 measures were reduced from 8.0% to 2.6% (cortex) and 7.1% to 2.8% (medulla) with StimFit, resulting in no significant differences for the CVs of intravendor repeat acquisitions (P = 0.13 and 0.05). "StimFit" significantly reduced the FWHM of T2 distributions in the cortex and whole kidney. DATA CONCLUSION: Stimulated-echo correction reduces renal T2 variation across MR vendor platforms. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY: Stage 1.

3.
Clin Endocrinol (Oxf) ; 99(3): 233-245, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37272391

RESUMO

OBJECTIVE: Primary hyperparathyroidism is a common endocrine disorder, with 80% of all cases usually caused by one single hyperfunctioning parathyroid adenoma. Conventional imaging modalities for the diagnostic work-up of primary hyperparathyroidism (PHPT) include ultrasound of the neck, 99mTc-sestamibi scintigraphy, and four-dimensional computed tomography (4D-CT). However, the role of other imaging modalities, such as 11C-methionine PET/CT, in the care pathway for PHPT is currently unclear. Here, we report our experience of the diagnostic utility of 11C-methionine PET/CT in a single-center patient cohort (n = 45). DESIGN: Retrospective single-center cohort study. PATIENTS AND MEASUREMENTS: The data of eligible patients that underwent 11C-methionine PET/CT between 2014 and 2022 at Addenbrooke's Hospital (Cambridge, UK) were collected and analyzed. The clinical utility of imaging modalities was determined by comparing the imaging result with histopathological and biochemical outcomes following surgery. RESULTS: In patients with persistent primary hyperparathyroidism following previous surgery, 11C-methionine PET/CT identified a candidate lesion in 6 of 10 patients (60.0%), and histologically confirmed in 5 (50.0%). 11C-methionine PET/CT also correctly identified a parathyroid adenoma in 9 out of 12 patients (75.0%) that failed to be localized on other imaging modalities. 11C-methionine PET/CT had a sensitivity of 70.0% (95% CI 55.8 - 84.2%) for the detection of parathyroid adenomas. CONCLUSIONS: This study highlights a diagnostic role for 11C-methionine PET/CT in patients that have undergone unsuccessful prior surgery or have equivocal or negative prior imaging results, aiding localization and a targeted surgical approach.


Assuntos
Adenoma , Hiperparatireoidismo Primário , Neoplasias das Paratireoides , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Hiperparatireoidismo Primário/diagnóstico por imagem , Hiperparatireoidismo Primário/etiologia , Neoplasias das Paratireoides/diagnóstico por imagem , Neoplasias das Paratireoides/complicações , Estudos Retrospectivos , Estudos de Coortes , Adenoma/diagnóstico , Adenoma/diagnóstico por imagem , Metionina , Tecnécio Tc 99m Sestamibi , Racemetionina , Reino Unido , Glândulas Paratireoides
4.
Br J Cancer ; 127(6): 1051-1060, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35739300

RESUMO

BACKGROUND: Surgery for renal cell carcinoma (RCC) with venous tumour thrombus (VTT) extension into the renal vein (RV) and/or inferior vena cava (IVC) has high peri-surgical morbidity/mortality. NAXIVA assessed the response of VTT to axitinib, a potent tyrosine kinase inhibitor. METHODS: NAXIVA was a single-arm, multi-centre, Phase 2 study. In total, 20 patients with resectable clear cell RCC and VTT received upto 8 weeks of pre-surgical axitinib. The primary endpoint was percentage of evaluable patients with VTT improvement by Mayo level on MRI. Secondary endpoints were percentage change in surgical approach and VTT length, response rate (RECISTv1.1) and surgical morbidity. RESULTS: In all, 35% (7/20) patients with VTT had a reduction in Mayo level with axitinib: 37.5% (6/16) with IVC VTT and 25% (1/4) with RV-only VTT. No patients had an increase in Mayo level. In total, 75% (15/20) of patients had a reduction in VTT length. Overall, 41.2% (7/17) of patients who underwent surgery had less invasive surgery than originally planned. Non-responders exhibited lower baseline microvessel density (CD31), higher Ki67 and exhausted or regulatory T-cell phenotype. CONCLUSIONS: NAXIVA provides the first Level II evidence that axitinib downstages VTT in a significant proportion of patients leading to reduction in the extent of surgery. CLINICAL TRIAL REGISTRATION: NCT03494816.


Assuntos
Axitinibe , Carcinoma de Células Renais , Neoplasias Renais , Trombose , Axitinibe/uso terapêutico , Carcinoma de Células Renais/tratamento farmacológico , Carcinoma de Células Renais/cirurgia , Humanos , Neoplasias Renais/tratamento farmacológico , Neoplasias Renais/cirurgia , Terapia Neoadjuvante , Nefrectomia , Estudos Retrospectivos , Trombose/prevenção & controle
5.
J Magn Reson Imaging ; 56(4): 1042-1052, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35224803

RESUMO

BACKGROUND: Three-dimensional variable flip angle (VFA) methods are commonly used for T1 mapping of the liver, but there is no data on the accuracy, repeatability, and reproducibility of this technique in this organ in a multivendor setting. PURPOSE: To measure bias, repeatability, and reproducibility of VFA T1 mapping in the liver. STUDY TYPE: Prospective observational. POPULATION: Eight healthy volunteers, four women, with no known liver disease. FIELD STRENGTH/SEQUENCE: 1.5-T and 3.0-T; three-dimensional steady-state spoiled gradient echo with VFAs; Look-Locker. ASSESSMENT: Traveling volunteers were scanned twice each (30 minutes to 3 months apart) on six MRI scanners from three vendors (GE Healthcare, Philips Medical Systems, and Siemens Healthineers) at two field strengths. The maximum period between the first and last scans among all volunteers was 9 months. Volunteers were instructed to abstain from alcohol intake for at least 72 hours prior to each scan and avoid high cholesterol foods on the day of the scan. STATISTICAL TESTS: Repeated measures ANOVA, Student t-test, Levene's test of variances, and 95% significance level. The percent error relative to literature liver T1 in healthy volunteers was used to assess bias. The relative error (RE) due to intrascanner and interscanner variation in T1 measurements was used to assess repeatability and reproducibility. RESULTS: The 95% confidence interval (CI) on the mean bias and mean repeatability RE of VFA T1 in the healthy liver was 34 ± 6% and 10 ± 3%, respectively. The 95% CI on the mean reproducibility RE at 1.5 T and 3.0 T was 29 ± 7% and 25 ± 4%, respectively. DATA CONCLUSION: Bias, repeatability, and reproducibility of VFA T1 mapping in the liver in a multivendor setting are similar to those reported for breast, prostate, and brain. LEVEL OF EVIDENCE: 1 TECHNICAL EFFICACY STAGE: 1.


Assuntos
Encéfalo , Imageamento por Ressonância Magnética , Encéfalo/diagnóstico por imagem , Feminino , Humanos , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Masculino , Imagens de Fantasmas , Próstata , Reprodutibilidade dos Testes
6.
MAGMA ; 33(1): 131-140, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31628564

RESUMO

PURPOSE: The potential of renal MRI biomarkers has been increasingly recognised, but clinical translation requires more standardisation. The PARENCHIMA consensus project aims to develop and apply a process for generating technical recommendations on renal MRI. METHODS: A task force was formed in July 2018 focused on five methods. A draft process for attaining consensus was distributed publicly for consultation and finalised at an open meeting (Prague, October 2018). Four expert panels completed surveys between October 2018 and March 2019, discussed results and refined the surveys at a face-to-face meeting (Aarhus, March 2019) and completed a second round (May 2019). RESULTS: A seven-stage process was defined: (1) formation of expert panels; (2) definition of the context of use; (3) literature review; (4) collection and comparison of MRI protocols; (5) consensus generation by an approximate Delphi method; (6) reporting of results in vendor-neutral and vendor-specific terms; (7) ongoing review and updating. Application of the process resulted in 166 consensus statements. CONCLUSION: The process generated meaningful technical recommendations across very different MRI methods, while allowing for improvement and refinement as open issues are resolved. The results are likely to be widely supported by the renal MRI community and thereby promote more harmonisation.


Assuntos
Rim/diagnóstico por imagem , Imageamento por Ressonância Magnética/normas , Nefrologia/normas , Pesquisa Translacional Biomédica/normas , Biomarcadores/metabolismo , Consenso , Técnica Delphi , Europa (Continente) , Prova Pericial , Humanos , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/tendências , Nefrologia/tendências , Padrões de Referência , Inquéritos e Questionários , Pesquisa Translacional Biomédica/tendências , Estados Unidos
7.
MAGMA ; 33(1): 177-195, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31676990

RESUMO

OBJECTIVES: Standardization is an important milestone in the validation of DWI-based parameters as imaging biomarkers for renal disease. Here, we propose technical recommendations on three variants of renal DWI, monoexponential DWI, IVIM and DTI, as well as associated MRI biomarkers (ADC, D, D*, f, FA and MD) to aid ongoing international efforts on methodological harmonization. MATERIALS AND METHODS: Reported DWI biomarkers from 194 prior renal DWI studies were extracted and Pearson correlations between diffusion biomarkers and protocol parameters were computed. Based on the literature review, surveys were designed for the consensus building. Survey data were collected via Delphi consensus process on renal DWI preparation, acquisition, analysis, and reporting. Consensus was defined as ≥ 75% agreement. RESULTS: Correlations were observed between reported diffusion biomarkers and protocol parameters. Out of 87 survey questions, 57 achieved consensus resolution, while many of the remaining questions were resolved by preference (65-74% agreement). Summary of the literature and survey data as well as recommendations for the preparation, acquisition, processing and reporting of renal DWI were provided. DISCUSSION: The consensus-based technical recommendations for renal DWI aim to facilitate inter-site harmonization and increase clinical impact of the technique on a larger scale by setting a framework for acquisition protocols for future renal DWI studies. We anticipate an iterative process with continuous updating of the recommendations according to progress in the field.


Assuntos
Biomarcadores/metabolismo , Imagem de Difusão por Ressonância Magnética , Rim/diagnóstico por imagem , Pesquisa Translacional Biomédica , Algoritmos , Consenso , Técnica Delphi , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Rim/metabolismo , Modelos Estatísticos , Movimento (Física) , Reprodutibilidade dos Testes , Inquéritos e Questionários
9.
MAGMA ; 33(1): 199-215, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31768797

RESUMO

Harmonization of acquisition and analysis protocols is an important step in the validation of BOLD MRI as a renal biomarker. This harmonization initiative provides technical recommendations based on a consensus report with the aim to move towards standardized protocols that facilitate clinical translation and comparison of data across sites. We used a recently published systematic review paper, which included a detailed summary of renal BOLD MRI technical parameters and areas of investigation in its supplementary material, as the starting point in developing the survey questionnaires for seeking consensus. Survey data were collected via the Delphi consensus process from 24 researchers on renal BOLD MRI exam preparation, data acquisition, data analysis, and interpretation. Consensus was defined as ≥ 75% unanimity in response. Among 31 survey questions, 14 achieved consensus resolution, 12 showed clear respondent preference (65-74% agreement), and 5 showed equal (50/50%) split in opinion among respondents. Recommendations for subject preparation, data acquisition, processing and reporting are given based on the survey results and review of the literature. These technical recommendations are aimed towards increased inter-site harmonization, a first step towards standardization of renal BOLD MRI protocols across sites. We expect this to be an iterative process updated dynamically based on progress in the field.


Assuntos
Rim/diagnóstico por imagem , Imageamento por Ressonância Magnética/tendências , Animais , Biomarcadores/metabolismo , Consenso , Técnica Delphi , Humanos , Rim/metabolismo , Imageamento por Ressonância Magnética/normas , Reprodutibilidade dos Testes , Razão Sinal-Ruído , Inquéritos e Questionários , Pesquisa Translacional Biomédica/tendências
10.
Neurosurg Focus ; 48(6): E8, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32480379

RESUMO

OBJECTIVE: The object of this study was to determine if revision transsphenoidal surgery (TSS), guided by 11C-methionine PET/CT coregistered with volumetric MRI (Met-PET/MRCR), can lead to remission in patients with persistent acromegaly due to a postoperative lateral disease remnant. METHODS: The authors identified 9 patients with persistent acromegaly following primary intervention (TSS ± medical therapy ± radiotherapy) in whom further surgery had initially been discounted because of equivocal MRI findings with suspected lateral sellar and/or parasellar disease (cases with clear Knosp grade 4 disease were excluded). All patients underwent Met-PET/MRCR. Scan findings were used by the pituitary multidisciplinary team to inform decision-making regarding repeat surgery. Revision TSS was performed with wide lateral exploration as guided by the PET findings. Endocrine reassessment was performed at 6-10 weeks after surgery, with longitudinal follow-up thereafter. RESULTS: Met-PET/MRCR revealed focal tracer uptake in the lateral sellar and/or parasellar region(s) in all 9 patients, which correlated with sites of suspected residual tumor on volumetric MRI. At surgery, tumor was identified and resected in 5 patients, although histological analysis confirmed somatotroph tumor in only 4 cases. In the other 4 patients, no definite tumor was seen, but equivocal tissue was removed. Despite the uncertainty at surgery, all patients showed immediate significant improvements in clinical and biochemical parameters. In the 8 patients for whom long-term follow-up data were available, insulin-like growth factor 1 (IGF-1) was ≤ 1.2 times the upper limit of normal (ULN) in all subjects and ≤ 1 times the ULN in 6 subjects, and these findings have been maintained for up to 28 months (median 8 months, mean 13 months) with no requirement for adjunctive medical therapy or radiotherapy. No patient suffered any additional pituitary deficit or other complication of surgery. CONCLUSIONS: This study provides proof of concept that Met-PET/MRCR can be helpful in the evaluation of residual lateral sellar/parasellar disease in persistent acromegaly and facilitate targeted revision TSS in a subgroup of patients.


Assuntos
Acromegalia/diagnóstico por imagem , Acromegalia/cirurgia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Reoperação/métodos , Osso Esfenoide/diagnóstico por imagem , Osso Esfenoide/cirurgia , Acromegalia/metabolismo , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudo de Prova de Conceito
11.
Clin Endocrinol (Oxf) ; 90(5): 670-679, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30721535

RESUMO

OBJECTIVE: To describe clinical practice experience of 11 C-Metomidate PET/CT as an adjunct to adrenal vein sampling (AVS) in the lateralization of aldosterone-producing adenomas (APA) in primary aldosteronism (PA). CONTEXT: Accurate lateralization of APA in the setting of PA offers the potential for surgical cure and improved long-term cardiovascular outcomes. Challenges associated with AVS, the current gold standard lateralization modality, mean that only a small proportion of potentially eligible patients currently make it through to surgery. This has prompted consideration of alternative strategies for lateralization, including the application of novel molecular PET tracers such as 11 C-Metomidate. DESIGN: Clinical Service Evaluation/Retrospective audit. PATIENTS: Fifteen individuals with a confirmed diagnosis of PA, undergoing lateralization with 11 C-Metomidate PET/CT prior to final clinical decision on surgical vs medical management. MEASUREMENTS: All patients underwent screening aldosterone renin ratio (ARR), followed by confirmatory testing with the seated saline infusion test, according to Endocrine Society Clinical Practice Guidelines. Adrenal glands were imaged using dedicated adrenal CT. 11 C-Metomidate PET/CT was undertaken due to equivocal or failed AVS. Management outcomes were assessed by longitudinal measurement of blood pressure, ARR, number of hypertensive medications following adrenalectomy or institution of medical therapy. RESULTS: We describe the individual lateralization and clinical outcomes for 15 patients with PA. CONCLUSION: 11 C-Metomidate PET/CT in conjunction with adrenal CT and AVS provided useful information which aided clinical decision-making for PA within a multidisciplinary hypertension clinic.


Assuntos
Tomada de Decisão Clínica , Etomidato/análogos & derivados , Hiperaldosteronismo/diagnóstico , Hiperaldosteronismo/terapia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Compostos Radiofarmacêuticos , Adulto , Humanos , Hiperaldosteronismo/tratamento farmacológico , Hiperaldosteronismo/cirurgia
12.
Ultraschall Med ; 40(6): 757-763, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29879743

RESUMO

PURPOSE: Optoacoustic imaging with ultrasound (OPUS) can assess in-vivo perfusion/oxygenation through surrogate measures of oxy, deoxy and total hemoglobin content in tissues. The primary aim of our study was to evaluate the ability of OPUS to detect physiological changes in the breast during the menstrual cycle and to determine qualitative/quantitative metrics of normal parenchymal tissue in pre-/post-menopausal women. The secondary aim was to assess the technique's repeatability. MATERIALS AND METHODS: We performed a prospective ethically approved study in volunteers using OPUS (700, 800 and 850 nm wavelengths) in the proliferative/follicular and secretory phase of the menstrual cycle. Regions of interest (ROIs) were drawn on the most superficial region of fibroglandular tissue and same-day intra-observer repeatability was assessed. We used t-tests to interrogate differences in the OPUS measurements due to hormonal changes and interclass correlation coefficients/Bland-Altman plots to evaluate the repeatability of mean ROI signal intensities. RESULTS: 22 pre-menopausal and 8 post-menopausal volunteers were recruited. 21 participants underwent repeatability examinations. OPUS intensity values were significantly higher (p < 0.0001) at all excitation wavelengths in the secretory compared to the proliferative/follicular phase. Post-menopausal volunteers showed similar optoacoustic values to the proliferative/follicular phase of pre-menopausal volunteers. The repeatability of the technique was comparable to other handheld ultrasound modalities. CONCLUSION: OPUS detects changes in perfusion/vascularity related to the menstrual cycle and menopausal status of breast parenchyma.


Assuntos
Neoplasias da Mama , Hormônios , Mama , Neoplasias da Mama/diagnóstico por imagem , Feminino , Hormônios/fisiologia , Humanos , Ciclo Menstrual , Óptica e Fotônica , Estudos Prospectivos
13.
Nephrol Dial Transplant ; 33(suppl_2): ii22-ii28, 2018 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-30137579

RESUMO

Tissue hypoxia plays a key role in the development and progression of many kidney diseases. Blood oxygenation level-dependent magnetic resonance imaging (BOLD-MRI) is the most promising imaging technique to monitor renal tissue oxygenation in humans. BOLD-MRI measures renal tissue deoxyhaemoglobin levels voxel by voxel. Increases in its outcome measure R2* (transverse relaxation rate expressed as per second) correspond to higher deoxyhaemoglobin concentrations and suggest lower oxygenation, whereas decreases in R2* indicate higher oxygenation. BOLD-MRI has been validated against micropuncture techniques in animals. Its reproducibility has been demonstrated in humans, provided that physiological and technical conditions are standardized. BOLD-MRI has shown that patients suffering from chronic kidney disease (CKD) or kidneys with severe renal artery stenosis have lower tissue oxygenation than controls. Additionally, CKD patients with the lowest cortical oxygenation have the worst renal outcome. Finally, BOLD-MRI has been used to assess the influence of drugs on renal tissue oxygenation, and may offer the possibility to identify drugs with nephroprotective or nephrotoxic effects at an early stage. Unfortunately, different methods are used to prepare patients, acquire MRI data and analyse the BOLD images. International efforts such as the European Cooperation in Science and Technology (COST) action 'Magnetic Resonance Imaging Biomarkers for Chronic Kidney Disease' (PARENCHIMA) are aiming to harmonize this process, to facilitate the introduction of this technique in clinical practice in the near future. This article represents an extensive overview of the studies performed in this field, summarizes the strengths and weaknesses of the technique, provides recommendations about patient preparation, image acquisition and analysis, and suggests clinical applications and future developments.


Assuntos
Biomarcadores/sangue , Rim/fisiologia , Oxigênio/metabolismo , Guias de Prática Clínica como Assunto/normas , Insuficiência Renal Crônica/fisiopatologia , Humanos , Hipóxia , Rim/irrigação sanguínea , Imageamento por Ressonância Magnética/métodos , Consumo de Oxigênio
14.
Nephrol Dial Transplant ; 33(suppl_2): ii29-ii40, 2018 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-30137580

RESUMO

Diffusion-weighted magnetic resonance imaging (DWI) is a non-invasive method sensitive to local water motion in the tissue. As a tool to probe the microstructure, including the presence and potentially the degree of renal fibrosis, DWI has the potential to become an effective imaging biomarker. The aim of this review is to discuss the current status of renal DWI in diffuse renal diseases. DWI biomarkers can be classified in the following three main categories: (i) the apparent diffusion coefficient-an overall measure of water diffusion and microcirculation in the tissue; (ii) true diffusion, pseudodiffusion and flowing fraction-providing separate information on diffusion and perfusion or tubular flow; and (iii) fractional anisotropy-measuring the microstructural orientation. An overview of human studies applying renal DWI in diffuse pathologies is given, demonstrating not only the feasibility and intra-study reproducibility of DWI but also highlighting the need for standardization of methods, additional validation and qualification. The current and future role of renal DWI in clinical practice is reviewed, emphasizing its potential as a surrogate and monitoring biomarker for interstitial fibrosis in chronic kidney disease, as well as a surrogate biomarker for the inflammation in acute kidney diseases that may impact patient selection for renal biopsy in acute graft rejection. As part of the international COST (European Cooperation in Science and Technology) action PARENCHIMA (Magnetic Resonance Imaging Biomarkers for Chronic Kidney Disease), aimed at eliminating the barriers to the clinical use of functional renal magnetic resonance imaging, this article provides practical recommendations for future design of clinical studies and the use of renal DWI in clinical practice.


Assuntos
Biomarcadores/análise , Imagem de Difusão por Ressonância Magnética/métodos , Rim/patologia , Guias de Prática Clínica como Assunto/normas , Insuficiência Renal Crônica/fisiopatologia , Humanos
15.
Nephrol Dial Transplant ; 33(suppl_2): ii4-ii14, 2018 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-30137584

RESUMO

Functional renal magnetic resonance imaging (MRI) has seen a number of recent advances, and techniques are now available that can generate quantitative imaging biomarkers with the potential to improve the management of kidney disease. Such biomarkers are sensitive to changes in renal blood flow, tissue perfusion, oxygenation and microstructure (including inflammation and fibrosis), processes that are important in a range of renal diseases including chronic kidney disease. However, several challenges remain to move these techniques towards clinical adoption, from technical validation through biological and clinical validation, to demonstration of cost-effectiveness and regulatory qualification. To address these challenges, the European Cooperation in Science and Technology Action PARENCHIMA was initiated in early 2017. PARENCHIMA is a multidisciplinary pan-European network with an overarching aim of eliminating the main barriers to the broader evaluation, commercial exploitation and clinical use of renal MRI biomarkers. This position paper lays out PARENCHIMA's vision on key clinical questions that MRI must address to become more widely used in patients with kidney disease, first within research settings and ultimately in clinical practice. We then present a series of practical recommendations to accelerate the study and translation of these techniques.


Assuntos
Biomarcadores/análise , Imageamento por Ressonância Magnética/métodos , Insuficiência Renal Crônica/classificação , Insuficiência Renal Crônica/patologia , Progressão da Doença , Humanos , Insuficiência Renal Crônica/terapia
16.
Radiology ; 279(2): 368-77, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26579563

RESUMO

PURPOSE: To investigate the effects of radiofrequency transmit field (B1(+)) correction on (a) the measured T1 relaxation times of normal breast tissue and malignant lesions and (b) the pharmacokinetically derived parameters of malignant breast lesions at 3 T. MATERIALS AND METHODS: Ethics approval and informed consent were obtained. Between May 2013 and January 2014, 30 women (median age, 58 years; range, 32-83 years) with invasive ductal carcinoma of at least 10 mm were recruited to undergo dynamic contrast material-enhanced magnetic resonance (MR) imaging before surgery. B1(+) and T1 mapping sequences were performed to determine the effect of B1(+) correction on the native tissue relaxation time (T10) of fat, parenchyma, and malignant lesions in both breasts. Pharmacokinetic parameters were calculated before and after correction for B1(+) variations. Results were correlated with histologic grade by using the Kruskal-Wallis test. RESULTS: Measurements showed a mean 37% flip angle difference between the right and left breast, which resulted in a 61% T10 difference in fat and a 41.5% difference in parenchyma between the two breasts. The T1 of lesions in the right breast increased by 58%, whereas that of lesions in the left breast decreased by 30% after B1(+) correction. The whole-tumor transendothelial permeability across the vascular compartment(K(trans)) of lesions in the right breast decreased by 41%, and that of lesions in the left breast increased by 46% after correction. A systematic increase in K(trans) was observed, with significant differences found across the histologic grades (P < .001). The effect size of B1(+) correction on K(trans) calculation was large for lesions in the right breast and moderate for lesions in the left breast (Cohen effect size, d = 0.86 and d = 0.59, respectively). CONCLUSION: B1(+) correction demonstrates a substantial effect on the results of quantitative dynamic contrast-enhanced analysis of breast tissue at 3 T, which propagates into the pharmacokinetic analysis of tumors that is dependent on whether the tumor is located in the right or left breast.


Assuntos
Neoplasias da Mama/patologia , Carcinoma Ductal de Mama/patologia , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia , Neoplasias da Mama/cirurgia , Carcinoma Ductal de Mama/cirurgia , Meios de Contraste/farmacocinética , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Estudos Prospectivos , Razão Sinal-Ruído
18.
Phys Med Biol ; 69(14)2024 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-38917824

RESUMO

Objective.A model-based alternating reconstruction coupling fitting, termed Model-based Alternating Reconstruction COupling fitting (MARCO), is proposed for accurate and fast magnetic resonance parameter mapping.Approach.MARCO utilizes the signal model as a regularization by minimizing the bias between the image series and the signal produced by the suitable signal model based on iteratively updated parameter maps when reconstructing. The technique can incorporate prior knowledge of both image series and parameters by adding sparsity constraints. The optimization problem is decomposed into three subproblems and solved through three alternating steps involving reconstruction and nonlinear least-square fitting, which can produce both contrast-weighted images and parameter maps simultaneously.Main results.The algorithm is applied toT2mapping with extended phase graph algorithm integrated and validated on undersampled multi-echo spin-echo data from both phantom and in vivo sources. Compared with traditional compressed sensing and model-based methods, the proposed approach yields more accurateT2maps with more details at high acceleration factors.Significance.The proposed method provides a basic framework for quantitative MR relaxometry, theoretically applicable to all quantitative MR relaxometry. It has the potential to improve the diagnostic utility of quantitative imaging techniques.


Assuntos
Algoritmos , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Imagens de Fantasmas , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Humanos , Fatores de Tempo , Encéfalo/diagnóstico por imagem
19.
Eur Radiol Exp ; 8(1): 76, 2024 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-38981998

RESUMO

BACKGROUND: Clinical imaging tools to probe aggressiveness of renal masses are lacking, and T2-weighted imaging as an integral part of magnetic resonance imaging protocol only provides qualitative information. We developed high-resolution and accelerated T2 mapping methods based on echo merging and using k-t undersampling and reduced flip angles (TEMPURA) and tested their potential to quantify differences between renal tumour subtypes and grades. METHODS: Twenty-four patients with treatment-naïve renal tumours were imaged: seven renal oncocytomas (RO); one eosinophilic/oncocytic renal cell carcinoma; two chromophobe RCCs (chRCC); three papillary RCCs (pRCC); and twelve clear cell RCCs (ccRCC). Median, kurtosis, and skewness of T2 were quantified in tumours and in the normal-adjacent kidney cortex and were compared across renal tumour subtypes and between ccRCC grades. RESULTS: High-resolution TEMPURA depicted the tumour structure at improved resolution compared to conventional T2-weighted imaging. The lowest median T2 values were present in pRCC (high-resolution, 51 ms; accelerated, 45 ms), which was significantly lower than RO (high-resolution; accelerated, p = 0.012) and ccRCC (high-resolution, p = 0.019; accelerated, p = 0.008). ROs showed the lowest kurtosis (high-resolution, 3.4; accelerated, 4.0), suggestive of low intratumoural heterogeneity. Lower T2 values were observed in higher compared to lower grade ccRCCs (grades 2, 3 and 4 on high-resolution, 209 ms, 151 ms, and 106 ms; on accelerated, 172 ms, 160 ms, and 102 ms, respectively), with accelerated TEMPURA showing statistical significance in comparison (p = 0.037). CONCLUSIONS: Both high-resolution and accelerated TEMPURA showed marked potential to quantify differences across renal tumour subtypes and between ccRCC grades. TRIAL REGISTRATION: ClinicalTrials.gov, NCT03741426 . Registered on 13 November 2018. RELEVANCE STATEMENT: The newly developed T2 mapping methods have improved resolution, shorter acquisition times, and promising quantifiable readouts to characterise incidental renal masses.


Assuntos
Neoplasias Renais , Imageamento por Ressonância Magnética , Gradação de Tumores , Humanos , Neoplasias Renais/diagnóstico por imagem , Neoplasias Renais/classificação , Neoplasias Renais/patologia , Imageamento por Ressonância Magnética/métodos , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Carcinoma de Células Renais/diagnóstico por imagem , Carcinoma de Células Renais/classificação , Carcinoma de Células Renais/patologia , Adulto
20.
Cancers (Basel) ; 15(5)2023 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-36900353

RESUMO

There is an unmet clinical need for imaging agents capable of detecting early evidence of tumor cell death, since the timing, extent, and distribution of cell death in tumors following treatment can give an indication of treatment outcome. We describe here 68Ga-labeled C2Am, which is a phosphatidylserine-binding protein, for imaging tumor cell death in vivo using positron emission tomography (PET). A one-pot synthesis of 68Ga-C2Am (20 min, 25 °C, >95% radiochemical purity) has been developed, using a NODAGA-maleimide chelator. The binding of 68Ga-C2Am to apoptotic and necrotic tumor cells was assessed in vitro using human breast and colorectal cancer cell lines, and in vivo, using dynamic PET measurements in mice implanted subcutaneously with the colorectal tumor cells and treated with a TRAIL-R2 agonist. 68Ga-C2Am showed predominantly renal clearance and low retention in the liver, spleen, small intestine, and bone and generated a tumor-to-muscle (T/m) ratio of 2.3 ± 0.4, at 2 h post probe administration and at 24 h following treatment. 68Ga-C2Am has the potential to be used in the clinic as a PET tracer for assessing early treatment response in tumors.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA