Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 193
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Arthroplasty ; 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38604280

RESUMO

BACKGROUND: Agreement on success following surgical treatment for periprosthetic joint infection (PJI) is important for comparing the efficacy of different surgical approaches with varying consequences and outcomes and setting patient expectations. We compared success rates following two-stage exchange arthroplasty for knee PJI using two expert-consensus definitions of success. METHODS: Prospectively documented data for 57 knees treated by a single surgeon at an academic tertiary care center were retrospectively reviewed. Treatment outcomes were quantified using the Delphi Consensus Criteria and the Musculoskeletal Infection Society Outcome Reporting Tool (MSIS ORT). RESULTS: Success rates were 81% using the Delphi Consensus Criteria and 56% using the MSIS ORT (P = .008). The MSIS ORT success rates increased to 76% when aseptic revisions and deaths unrelated to PJI were not penalized as failures of treatment. Predicted probabilities of successful treatment in a hypothetical case scenario were lowest based on the MSIS ORT and similarly higher using Delphi Consensus Criteria and MSIS ORT modified for both women (53.0, 90.8, and 88.7%) and men (29.1, 89.1, and 89.3%). CONCLUSIONS: Study observations underscore the need for a uniformly accepted single definition of surgical treatment success.

2.
J Arthroplasty ; 39(5): 1304-1311, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-37924992

RESUMO

BACKGROUND: Tapered, fluted titanium (TFT) femoral stems have become the gold standard in revision total hip arthroplasty (rTHA). However, there is a paucity of data on TFT stem subsidence rates following aseptic rTHA. Subsidence can lead to instability, mechanical failure, leg-length discrepancy, and may require revision surgery. This study evaluated the incidences and predictors of TFT subsidence in aseptic rTHA. METHODS: A total of 102 TFT femoral stems of 4 designs were retrospectively reviewed. Stem subsidence was measured on digital radiographs taken immediately after surgery and at standard clinical follow-up. Patient characteristics, risk factors for subsidence, revision etiologies, and implant characteristics were recorded. Patient-reported outcome measures were also evaluated for a subset of cases. RESULTS: Overall, 12% of stems subsided >1 cm, and subsidence was minimal (<3 mm) in ≥64% of cases. From immediate postoperative to 1-month radiographic follow-up, 79% of stems subsided a mean of 2.9 mm (range, 0.1 to 12 mm). Beyond 1 month, subsidence was minimal for ≥77% of cases. In multivariate analyses, women and less femoral implant canal fill were associated with greater subsidence (P ≤ .034). The TFT stem design was not associated with early subsidence (P = .816). There were no modular junction fractures. There were 2 fractures and 2 subsidence-related revisions for aseptic loosening that occurred postoperatively. CONCLUSIONS: The amount of subsidence in TFT stems was low and was detectable in the early (less than 1 year) postoperative period. Maximizing TFT stem fill within the femoral canal appears to reduce the risk of subsidence without increasing femoral fracture rates and should be the goal with implantation of these devices. LEVEL OF EVIDENCE: IV-Case Series, No Control Group.

3.
J Arthroplasty ; 2024 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-38336307

RESUMO

BACKGROUND: Leaving the patella unresurfaced in total knee arthroplasty (TKA) has increased significantly over the past decade in the United States, likely due to modern patella-friendly implants, complications with resurfacing, and the knowledge that historical studies were scientifically confounded. This study evaluated revision-free survivorship out to 8.5 years in a cohort of contemporary primary TKAs with patella-friendly femoral components and unresurfaced patellae. METHODS: A total of 1,053 consecutive primary TKAs with unresurfaced patellae were retrospectively reviewed. A selective patellar nonresurfacing protocol was used for all cases. Kaplan-Meier survivorship estimates were calculated based on patellar revision and the latest follow-up. An aggressive lateral patellar facetectomy was performed in 78% (823 of 1,053) of cases. The cohort was 62% women and 43% American Society of Anesthesiologists physical status classification I or II with a mean age and body mass index of 65 years (range, 35 to 94) and 35 kg/m2 (range, 18 to 65), respectively. RESULTS: A total of 4 (0.4%, 4 of 1,053) unresurfaced patellae were revised. Three were resurfaced as part of other procedures: 2 for global instability and one for aseptic loosening at a mean of 1.6 years; and one patella was resurfaced by an outside surgeon for unexplained pain. The all-cause revision-free survivorship estimate specifically related to the patella was 98.9% (95% confidence interval, 98 to 100) out to 8.5 years. No significant difference in survivorship was related to patellae with or without a lateral patellar facetectomy (99.5 versus 98.1%, P ≥ .191); however, 3 of 4 patellar revisions occurred in TKAs without a lateral patellar facetectomy (P = .035). CONCLUSIONS: The results of this study demonstrate excellent revision-free survivorship related to unresurfaced patellae, particularly when a lateral facetectomy was performed. These early to midterm results using modern patella-friendly femoral components are promising and comparable to resurfaced patellae in the literature. LEVEL OF EVIDENCE: IV.

4.
J Arthroplasty ; 2024 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-38734325

RESUMO

BACKGROUND: The use of conforming and congruent bearings in total knee arthroplasty (TKA) have rapidly increased due to the benefits of increased stability and the potential for replicating normal knee kinematics. However, limited data exist for these newly available bearings. This study evaluated revision-free survivorship and patient-reported outcome measures (PROMs) of a large granular database of primary TKAs using a single conforming bearing design. METHODS: A total of 1,306 consecutive primary TKAs performed using a single conforming bearing design (85% cemented and 15% cementless) were retrospectively reviewed. Kaplan-Meier survivorship estimates were calculated based on the latest clinical follow-up. The PROMs and minimal clinically important differences were evaluated. A total of 93% of cases achieved minimum 1-year clinical follow-up (mean 3.5 years; range, 1 to 7), with a subset of 261 cases that achieved minimum 5-year follow-up (mean 5.8 years; range, 5 to 7). RESULTS: All-cause and aseptic Kaplan-Meier survivorship estimates were 97.6 (95% CI [confidence interval], 97 to 99) and 98.1% (95% CI, 97 to 99) at 7.0 years. Revision-free survivorship did not differ by cemented or cementless fixation (98 versus 97%, P = .163). All PROM scores significantly improved from preoperative baseline (P < .001), and ≥ 86% of patients achieved minimal clinically important differences for Knee Society pain and Knee Injury and Osteoarthritis Outcome Score for Joint Replacement total scores. A total of 89% of cases reported their knees to 'sometimes or always' feel normal. For cases with minimum 5-year PROMs, 93% were 'very satisfied' or 'satisfied.' CONCLUSIONS: Conforming-bearing TKA demonstrated excellent survivorship up to 7.0 years. In addition, PROMs were comparable to other designs reported in the literature. While mid-term (mean 3.5-year) results are promising, long-term data are warranted on survivorship due to potential polyethylene wear in conforming bearings with more surface area in contact with articulating surfaces. LEVEL OF EVIDENCE: IV.

5.
J Arthroplasty ; 39(3): 632-637, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37717834

RESUMO

BACKGROUND: Two related recent reports described high error rates for implant positioning and reduced implant survivorship in manual unicompartmental knee arthroplasty (MUKA) compared to robotic-assisted unicompartmental knee arthroplasty (RUKA). The present study scientifically replicated these reports by comparing MUKAs similarly performed by an experienced high-volume surgeon in similar patients using the same study methods as these reports. METHODS: A total of 216 consecutive MUKAs were retrospectively evaluated radiographically for achievement of implant positioning targets. Achievement of targets was compared to the published MUKA and RUKA outcomes and correlated with revision rates and patient-reported outcome measures. RESULTS: There were 20% of study MUKAs compared to 88.1% of comparison MUKAs (P < .001) and 31.4% of comparison RUKAs (P < .048) that failed to meet all 7 implant positioning targets. The MUKA revision rates were significantly lower in the study sample than for comparison MUKAs (3.2% versus 14.2%, P < .001). Implant survivorship was 91.7% (95% confidence interval 84.9, 98.5%) at 8.9 years compared to 70.0% (95% confidence interval 56.0, 80.0%) at 10.2 years, respectively. Most patient-reported outcome measures did not differ based on achievement of implant positioning targets (P ≥ .072). CONCLUSIONS: Present study findings indicate that observations in the 2 recent reports may not be generalizable to all UKA surgeons. Additional data on the relationship between implant positioning and revision as well as functional outcomes are needed to identify appropriate robotic arthroplasty applications.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Procedimentos Cirúrgicos Robóticos , Humanos , Artroplastia do Joelho/métodos , Estudos Retrospectivos , Sobrevivência , Osteoartrite do Joelho/cirurgia , Procedimentos Cirúrgicos Robóticos/métodos , Medidas de Resultados Relatados pelo Paciente , Resultado do Tratamento , Articulação do Joelho/cirurgia
6.
J Arthroplasty ; 39(3): 591-599, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38007204

RESUMO

Mechanical alignment (MA) and its tenets have been considered essential for total knee arthroplasty (TKA) success since they were introduced in 1973. However, over time, there have been colossal advances in our knowledge and understanding of the anatomy and kinematics of the knee, as well as in surgical precision and implants. However, the MA systematic principles of prosthetic arthroplasty and implant position related to the lower-extremity mechanical axis, have only recently been called into question. The high rates of dissatisfaction and residual pain reported after MA TKA prompted this questioning, and that leaves plenty of room for improvement. Despite the general consensus that there is great variability between patients' anatomy, it is still the norm to carry out a systematic operation that does not consider individual variations. Evolving to a more personalized arthroplasty surgery was proposed as a rational and reasonable option to improve patient outcomes. Transitioning to a personalized TKA approach requires questioning and even disregarding certain MA TKA principles. Based on current knowledge, we can state that certain principles are erroneous or unfounded. The aim of this narrative review was to discuss and challenge 10 previously accepted, yet we believe, flawed, principles of MA, and to present an alternative concept, which is rooted in personalized TKA techniques.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Humanos , Artroplastia do Joelho/métodos , Articulação do Joelho/cirurgia , Articulação do Joelho/anatomia & histologia , Extremidade Inferior/cirurgia , Fenômenos Biomecânicos , Osteoartrite do Joelho/cirurgia
7.
J Arthroplasty ; 2024 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-38458333

RESUMO

BACKGROUND: Total knee arthroplasty (TKA) is one of the most common procedures in orthopaedics, but there is still debate over the optimal fixation method for long-term durability: cement versus cementless bone ingrowth. Recent improvements in implant materials and technology have offered the possibility of cementless TKA to change clinical practice with durable, stable biological fixation of the implants, improved operative efficiency, and optimal long-term results, particularly in younger and more active patients. METHODS: This symposium evaluated the history of cementless TKA, the recent resurgence, and appropriate patient selection, as well as the historical and modern-generation outcomes of each implant (tibia, femur, and patella). Additionally, surgical technique pearls to assist in reliable, reproducible outcomes were detailed. RESULTS: Historically, cemented fixation has been the gold standard for TKA. However, cementless fixation is increasing in prevalence in the United States and globally, with equivalent or improved results demonstrated in appropriately selected patients. CONCLUSIONS: Cementless TKA provides durable biologic fixation and successful long-term results with improved operating room efficiency. Cementless TKA may be broadly utilized in appropriately selected patients, with intraoperative care taken to perform meticulous bone cuts to promote appropriate bony contact and biologic fixation.

8.
J Arthroplasty ; 39(1): 32-37, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37549756

RESUMO

BACKGROUND: Access to high-quality care for revision total joint arthroplasty (rTJA) is poorly understood but may vary based on insurance type. This study investigated distance traveled for hip and knee rTJA based on insurance type. METHODS: A total of 317 revision hips and 431 revision knees performed between 2010 and 2020 were retrospectively reviewed. Cluster sampling was used to select primary hips and knees for comparison. Median driving distance was compared based upon procedure and insurance type. RESULTS: Revision hip and knee patients traveled 18.2 and 11.0 miles farther for surgery compared to primary hip and knee patients (P ≤ .001). For hip rTJA, Medicaid patients traveled farther than Medicare patients followed by commercially insured patients with median distances traveled of 98.4, 67.2, and 35.6 miles, respectively (P = .016). Primary hip patients traveled the same distance regardless of insurance type (P = .397). For knee rTJA, Medicaid patients traveled twice as far as Medicare and commercially insured patients (medians of 85.0, 43.5, and 42.2 miles respectively, P ≤ .046). Primary knee patients showed a similar pattern (P = .264). Age and ASA-PS classification did not indicate greater comorbidity in Medicaid patients. CONCLUSION: Insurance type may influence rTJA referrals, with disproportionate referral of Medicaid and Medicare patients to nonlocal care centers. In addition to patient burden, these patterns potentially present a financial burden to facilities accepting referrals. Strategies to improve equitable access to rTJA, while maintaining the highest and most economical standards of care for patients, providers, and hospitals, are encouraged.


Assuntos
Artroplastia de Quadril , Artroplastia do Joelho , Idoso , Humanos , Estados Unidos , Medicaid , Medicare , Estudos Retrospectivos
9.
J Arthroplasty ; 2024 Feb 24.
Artigo em Inglês | MEDLINE | ID: mdl-38408715

RESUMO

BACKGROUND: Cementless femoral fixation in total hip arthroplasty (THA) has increased in prevalence worldwide. However, cementless fixation in elderly patients is controversial due to the risks of periprosthetic fracture and aseptic loosening. This study evaluated outcomes in patients undergoing primary THA utilizing a cementless stem without a collar, comparing those less than 75 years to those older than 75 years. METHODS: Between 2011 and 2021, there were 2,605 cementless THAs performed by 4 surgeons utilizing a highly porous metal fixation surface without a collar and consistent clinical protocols. There were 469 patients who had an age ≥ 75 years. Revision rates, intraoperative fractures, and 90-day mortality were compared between cohorts. In the ≥ 75 year age group, there were more women, more American Society of Anesthesiologists physical status classification III or IV, a lower body mass index, and more kidney disease, osteoporosis, and thyroid disease (P ≤ .002). RESULTS: All-cause revision rates trended lower for the ≥75 year age group compared to < 75 year (1.9 versus 3.5%, P = .082) at 20-months of follow-up. Moreover, there was no difference in all-cause femoral component revisions comparing ≥ 75 to < 75 year age groups (1.5 versus 2.2%, P = .375), with only 3 of 10 femoral revisions due to aseptic loosening being in the ≥ 75 year age group. Intraoperative fracture (0.2 versus 0.5%, P = .701) and 90-day mortality (0.2 versus 0.1%, P = .460) did not differ between ≥ 75 and < 75 year age groups. CONCLUSIONS: Older patients had comparable revision rates compared to younger patients using cementless femoral fixation without a collar. Furthermore, there was no difference in 90-day mortality or intraoperative fracture rates. Study findings provide evidence for the safety and durability of cementless THA using collarless femoral stems in elderly patients ≥ 75 years of age. LEVEL OF EVIDENCE: III.

10.
J Arthroplasty ; 38(1): 146-151, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35843381

RESUMO

BACKGROUND: Serum and synovial biomarkers are currently used to diagnose periprosthetic joint infection (PJI). Serum neutrophil-to-lymphocyte ratio (NLR) has shown promise as an inexpensive test in diagnosing infection, but there are no reports of synovial NLR or absolute neutrophil count (ANC) for diagnosing chronic PJI. The purpose of this study was to investigate the diagnostic potential of both markers. METHODS: A retrospective review of 730 patients who underwent total joint arthroplasty and subsequent aspiration was conducted. Synovial white blood cell (WBC) count, synovial polymorphonuclear percentage (PMN%), synovial NLR, synovial ANC, serum erythrocyte sedimentation rate (ESR), serum C-reactive protein (CRP), serum WBC, serum PMN%, serum NLR, and serum ANC had their utility in diagnosing PJI examined by area-under-the-curve analyses (AUC). Pairwise comparisons of AUCs were performed. RESULTS: The AUCs for synovial WBC, PMN%, NLR, and ANC were 0.84, 0.84, 0.83, and 0.85, respectively. Synovial fluid ANC was a superior marker to synovial NLR (P = .027) and synovial WBC (P = .003) but not PMN% (P = .365). Synovial NLR was inferior to PMN% (P = .006) but not different from synovial WBC (P > .05). The AUCs for serum ESR, CRP, WBC, PMN%, NLR, and ANC were 0.70, 0.79, 0.63, 0.72, 0.74, and 0.67, respectively. Serum CRP outperformed all other serum markers (P < .05) except for PMN% and NLR (P > .05). Serum PMN% and NLR were similar to serum ESR (P > .05). CONCLUSION: Synovial ANC had similar performance to PMN% in diagnosing chronic PJI, whereas synovial NLR was a worse diagnostic marker. The lack of superiority to synovial PMN% limits the utility of these tests compared to established criteria.


Assuntos
Artrite Infecciosa , Artroplastia de Quadril , Infecções Relacionadas à Prótese , Humanos , Líquido Sinovial/química , Infecções Relacionadas à Prótese/cirurgia , Neutrófilos , Contagem de Leucócitos , Artrite Infecciosa/cirurgia , Sedimentação Sanguínea , Proteína C-Reativa/análise , Linfócitos , Biomarcadores , Estudos Retrospectivos
11.
J Arthroplasty ; 38(10): 2032-2036, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-36503105

RESUMO

BACKGROUND: With the emergence of advanced technology, such as robotics, three-dimensional (3D) imaging is necessary to execute preoperative surgical plans accurately. However, 3D imaging adds cost and potential risk to patients. This study determined the measurement accuracy, reliability, and repeatability of a novel artificial intelligence (AI) algorithm which converts two-dimensional (2D) radiographs to 3D bone models. METHODS: An AI algorithm was developed to convert 2D radiographs to 3D bone model reconstructions. The accuracy of the AI algorithm was evaluated by comparing mean absolute error in measurements performed on 3D bone reconstructions, 3D computed tomography (CT) scans, and manual measurements on five cadaveric knees. Reliability and repeatability of the AI algorithm were evaluated by assessing the inter-observer and intra-observer agreement between measurements performed on 3D bone reconstructions, respectively. RESULTS: Accuracy of the AI algorithm was considered excellent with mean absolute errors <2mm in 9 of 12 anatomical parameters compared with measurements performed on CTs and manual calipers. All inter-observer and intra-observer correlation coefficients were greater than 0.90 representing a high level of measurement reliability and repeatability by independent observers and the same observers. CONCLUSION: This particular AI algorithm demonstrated a high degree of accuracy, reliability, and repeatability for converting 2D radiographs to 3D bone reconstructions similar to a CT-scan. Study results suggest this AI algorithm has the potential for use in preoperative surgical planning due to its efficiencies related to cost and time and reduced radiation exposure without the use of 3D imaging.


Assuntos
Artroplastia do Joelho , Humanos , Artroplastia do Joelho/efeitos adversos , Inteligência Artificial , Reprodutibilidade dos Testes , Radiografia , Algoritmos , Imageamento Tridimensional/métodos , Variações Dependentes do Observador
12.
J Arthroplasty ; 38(3): 491-496, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36252746

RESUMO

BACKGROUND: Leaving the patella unresurfaced in total knee arthroplasty (TKA) is increasing due to modern patella-friendly implants, awareness that complications are not uncommon with resurfacing, and knowledge that historical studies were scientifically confounded. This study examined the effect of selective patellar resurfacing on patient-reported outcome measures (PROMs) using modern implants and techniques in cohorts rigorously matched for demographics and osteoarthritis severity. METHODS: A total of 166 TKAs performed without patellar resurfacing were case-control matched to 166 TKAs with patella resurfacing. Case-control matching was based on demographics, American Society of Anesthesiology Physical Status, comorbidities, and osteoarthritis severity. No significant differences were observed between cohorts for demographics (P ≥ .347), comorbidities (P ≥ .443), or radiographic osteoarthritis severity (P ≥ .078). Radiographic alignment and prospectively collected PROMs were evaluated preoperatively and at latest clinical follow-up. RESULTS: Preoperatively, patellar tilt was less for the unresurfaced patella group (3 versus 4°, P = .003); however, postoperative patellar tilt was not different (3 versus 3°, P = .225). At a mean of 2.1 years follow-up (range, 1 to 7), University of California Los Angeles Activity Level was significantly higher for the unresurfaced patella group (6.3 versus 5.5, P = .002), but the mean group difference did not reach a minimal clinically important difference. There were no other significant differences in PROMs or reoperation rates between cohorts (P ≥ .135). CONCLUSION: In contemporary cruciate retaining and substituting TKA designs, not resurfacing the patella in select patients may achieve comparable PROMs and re-operation rates; and potentially greater activity level compared to patella resurfacing at early follow-up. LEVEL OF EVIDENCE: III.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Humanos , Artroplastia do Joelho/métodos , Articulação do Joelho/cirurgia , Patela/cirurgia , Osteoartrite do Joelho/cirurgia , Resultado do Tratamento , Estudos de Coortes
13.
J Arthroplasty ; 38(7): 1356-1362, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36693514

RESUMO

BACKGROUND: Accurate diagnosis of persistent periprosthetic joint infection (PJI) during 2-stage exchange remains a challenge. This study evaluated the diagnostic performance and thresholds of several commonly obtained serum and synovial markers to better guide reimplantation timing. METHODS: This was a retrospective review of 249 patients who underwent 2-stage exchange with antibiotic spacers for PJI. Serum and synovial markers analyzed included white blood cell (WBC) count, polymorphonuclear percentage (PMN%), neutrophil-to-lymphocyte ratio (NLR), and absolute neutrophil count (ANC). Serum markers analyzed were erythrocyte sedimentation rate (ESR), C-reactive protein (CRP), as well as percentage change in ESR and CRP from initial diagnosis to reimplantation. Area under the curve (AUC) analyses were performed to determine diagnostic accuracy of detecting PJI. RESULTS: In TKAs, synovial ANC and WBC had the highest AUCs (0.76), with thresholds of 2,952 and 3,800 cells/µL, respectively. The next best marker was serum CRP (0.73) with a threshold of 5.2 mg/dL. In THAs, serum CRP had the highest AUC (0.84) with a threshold of 4.3 mg/dL, followed by synovial PMN% (0.80) with a threshold of 77%. Percentage change in serum ESR or CRP provided low diagnostic value overall. CONCLUSION: Regarding serum markers, CRP consistently performed well in detecting persistent PJI in patients with antibiotic spacers. Absolute values of serum CRP and ESR had better diagnostic value than trends for guiding reimplantation timing. Diagnostic performance differed with joint type; however, synovial markers outperformed serum counterparts. No marker alone can be utilized to diagnose residual PJI in these patients, and further work is needed in this domain.


Assuntos
Artrite Infecciosa , Artroplastia de Quadril , Infecções Relacionadas à Prótese , Humanos , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/cirurgia , Líquido Sinovial/química , Proteína C-Reativa/análise , Biomarcadores , Artrite Infecciosa/cirurgia , Sedimentação Sanguínea , Estudos Retrospectivos , Sensibilidade e Especificidade
14.
J Arthroplasty ; 38(7 Suppl 2): S245-S251, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37100094

RESUMO

BACKGROUND: Advanced technologies, like robotics, provide enhanced precision for implanting total knee arthroplasty components; however, optimal component position and limb alignment remain unknown. This study sought to identify sagittal and coronal alignment targets that correlate with minimal clinically important differences (MCIDs) in patient-reported outcome measures (PROMs). METHODS: A total of 1,311 consecutive total knee arthroplasties were retrospectively reviewed. Posterior tibial slope (PTS), femoral flexion (FF), and tibio-femoral alignment (TFA) were measured radiographically. Patients were grouped based on whether they achieved multiple MCIDs for PROM scores. Classification and regression tree machine learning models were utilized to identify optimal alignment zones. The mean follow-up was 2.4 years (range, 1 to 11). RESULTS: The change in PTS and postoperative TFA were most predictive for achieving MCIDs in 90% of the models. Approximating native PTS within 4° correlated with MCID achievement and superior PROMs. Preoperative varus and neutral aligned knees were more likely to meet MCIDs and superior PROM scores when not overcorrected into valgus postoperatively (≥7°). Preoperative valgus-aligned knees correlated with MCID achievement when postoperative TFA was not overcorrected into substantial varus (<0°). Albeit less impactful, FF ≤ 7° correlated with MCID achievement and superior PROMs regardless of preoperative alignment. Sagittal and coronal alignment measurements had moderate to strong interactions in 13 of 20 models. CONCLUSION: Optimized PROM MCIDs correlated with approximating native PTS while maintaining similar preoperative TFA and incorporating moderate FF. Study findings demonstrate interactions between sagittal and coronal alignment which may optimize PROMs, highlighting the importance of three-dimensional implant alignment targets. LEVEL OF EVIDENCE: III.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Humanos , Artroplastia do Joelho/métodos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Estudos Retrospectivos , Joelho/cirurgia , Osteoartrite do Joelho/cirurgia , Tíbia/cirurgia
15.
J Arthroplasty ; 38(12): 2484-2491, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37595768

RESUMO

BACKGROUND: Body mass index (BMI) cutoffs have been established for total knee arthroplasty (TKA) patients due to increased risk of medical complications in obese patients. However, evidence-based medical optimization may mitigate risk in these patients. This study examined the influence of BMI on patient-reported outcome measures (PROMs) following primary TKA with specialized perioperative optimization. METHODS: Between 2016 and 2020, 1,329 consecutive primary TKAs using standardized perioperative optimization were retrospectively reviewed. Patients were categorized into ordinal groups based on BMI in 5 kg/m2 increments (range, 17 to 61). Primary outcomes related to activity level, pain, function, and satisfaction were evaluated. BMI groups ≥35 had significantly lower age, more women, and higher prevalence of comorbidities (P ≤ .004). Mean follow-up was 1.7 years (range, 1 to 5 years). RESULTS: Each successive BMI group from 35 to ≥50 demonstrated continually greater improvement in pain with level walking and stair climbing (P ≤ .001), Knee Injury and Osteoarthritis Outcome Score for Joint Replacement (P = .001), and greater satisfaction (P = .007). No patients who had a BMI ≥35 were revised for aseptic loosening, and rates of periprosthetic joint infection were not different between BMI groups (P = 1.000). CONCLUSION: Despite being more debilitated preoperatively, patients who had a BMI ≥35 experienced greater improvements in PROMs compared to patients who had lower BMI. Given the significant improvements in PROMs and quality of life in obese patients, with appropriate perioperative optimization, these patients should not be prohibited from having a TKA when appropriately indicated. LEVEL OF EVIDENCE: III.


Assuntos
Artroplastia do Joelho , Osteoartrite do Joelho , Humanos , Feminino , Artroplastia do Joelho/efeitos adversos , Estudos Retrospectivos , Qualidade de Vida , Obesidade/complicações , Obesidade/cirurgia , Osteoartrite do Joelho/complicações , Medidas de Resultados Relatados pelo Paciente , Dor/cirurgia , Articulação do Joelho/cirurgia , Resultado do Tratamento
16.
J Arthroplasty ; 38(7S): S124-S130, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36791889

RESUMO

BACKGROUND: Postoperative dislocation is considered the main drawback of posterior approach total hip arthroplasty (THA). Thinner highly cross-linked polyethylene and dual-mobility bearings allow maximizing femoral head diameter per a given cup size. This study evaluated dislocation rates as large femoral head bearings were introduced into a practice over an 11-year period. METHODS: A total of 1,511 consecutive primary THAs were retrospectively reviewed. Demographics, implant sizes, femoral head-acetabular cup ratio, and dislocation status were collected from the electronic medical record. Data were evaluated using time series analysis techniques as larger femoral heads, thinner polyethylene liners, and dual-mobility bearings were introduced. The cohort was 57% women with mean age and body mass index of 62 years (range, 13 to 93) and 31 kg/m2 (range, 13 to 54), respectively. RESULTS: The overall dislocation rate was 0.98%. Use of femoral head sizes ≥ 40 millimeters increased from 4% in the years 2010 to 2016 to 51% in the years 2017 to 2021, correlating with a 50% reduction in dislocation rate from 1.4% to 0.7% (P = .279). Also, no dislocations occurred in patients who had dual-mobility bearings or ≥ 40-millimeter femoral heads (P = .007). Twelve of 14 dislocations occurred in cases with head-cup ratio < 0.7 (P = .013). Thirteen of 14 dislocations were in women (P = .005). CONCLUSION: Maximizing the femoral head diameter per given cup size correlated with a decrease in dislocation rate in modern posterior approach THA. Furthermore, these results suggest that dual-mobility articulations should be reserved for high-risk patients or patients in whom a 40-millimeter femoral head is not possible. LEVEL OF EVIDENCE: IV-consecutive case series; no control group.


Assuntos
Artroplastia de Quadril , Luxação do Quadril , Prótese de Quadril , Luxações Articulares , Humanos , Feminino , Masculino , Artroplastia de Quadril/efeitos adversos , Cabeça do Fêmur/cirurgia , Prótese de Quadril/efeitos adversos , Estudos Retrospectivos , Desenho de Prótese , Luxações Articulares/cirurgia , Polietileno , Reoperação , Luxação do Quadril/epidemiologia , Luxação do Quadril/etiologia , Luxação do Quadril/prevenção & controle , Falha de Prótese
17.
J Arthroplasty ; 38(6S): S145-S150, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36791890

RESUMO

BACKGROUND: Cementless fixation in total knee arthroplasty (TKA) is re-emerging due to improvements in biomaterials, surgical technique, and implant design. Albeit rare, failure of osseointegration typically occurs within the first 2 years, and limited data exist on survivorship of the modern cementless TKA designs. This study evaluated clinical survivorship of 2 contemporary cementless TKA designs at minimum 2-year follow-up. METHODS: A total of 627 cementless TKAs were performed up to July 2022. Three hundred thirty-nine cases were eligible for 2-year follow-up. Indications centered around bone quality and involved predominantly younger patients. The 2 designs consisted of tibial components with a highly porous titanium ingrowth surface, a central keel, and peripheral cruciform pegs with a porous cobalt-chromium femur. Survivorship estimates were calculated using right-censored non-parametric Kaplan-Meier methodologies. A total of 226 TKAs obtained minimum 2-year follow-up with a mean of 3.6 years (range, 2 to 10). RESULTS: The all-cause revision rate was 2.4% (8 of 339). The revision rate due to aseptic loosening was 0.6% (2 of 339) consisting of 2 femoral components. No tibial components were revised for aseptic loosening. Kaplan-Meier survivorship free from aseptic loosening was 99% (95% confidence interval 98 to 100) at a maximum of 10 years. CONCLUSION: These results demonstrate encouraging survivorship of cementless fixation in primary TKA with use of contemporary ingrowth biomaterials and modern implant designs. This particular tibial implant design with a highly porous titanium fixation surface, central keel, and peripheral cruciform pegs demonstrated excellent clinical survivorship without failure which may portend superior fixation. LEVEL OF EVIDENCE: IV-case series, no control group/historical control group.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Humanos , Artroplastia do Joelho/métodos , Titânio , Fêmur/cirurgia , Materiais Biocompatíveis , Reoperação , Desenho de Prótese , Falha de Prótese , Resultado do Tratamento , Seguimentos
18.
J Arthroplasty ; 38(6S): S227-S231, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36781062

RESUMO

BACKGROUND: As robotic-assisted total knee replacement (rTKA) continues to gain popularity, the impact of this technology on resident education remains unknown. The purpose of this study was to describe trainee experience and perceptions of rTKA and its effect on surgical training. METHODS: Two hundred and twenty two senior orthopaedic residents attending a national board review course completed a 17-question survey regarding their experience and perceptions regarding rTKA. Mean and standard deviations were calculated for Likert scale questions, and bivariate analyses were utilized to compare answer groups. RESULTS: Seventy percent of respondents reported exposure to rTKA during their training. Of those with robotic exposure, 20% reported that greater than half of their TKA experience involved robotics. Only 29% percent agreed that robotics improved outcomes, whereas 21% disagreed and the remainder were unsure. Over half of respondents agreed that robotics are used primarily for marketing purposes. Of those who trained with rTKA, 45% percent believed that robotics improved their understanding of the surgical procedure; however, 25% felt robotics negatively compromised their training with traditional instrumentation. Higher robotic case exposure (P = .001) and attending an industry-sponsored course (P = .02) was associated with the belief that robotics improved outcomes. Robotic case volume and percentage was associated with the belief that robotics improved understanding of the surgical procedure, however, it also was associated with reduced comfort performing traditional knee arthroplasty (P = .001). CONCLUSION: Current resident training experience varies greatly within the United States with regards to rTKA. While exposure to rTKA may be beneficial for a well-rounded surgical education, over-exposure likely results in decreased comfort with traditional instrumentation.


Assuntos
Artroplastia do Joelho , Ortopedia , Procedimentos Cirúrgicos Robóticos , Robótica , Humanos , Artroplastia do Joelho/métodos , Procedimentos Cirúrgicos Robóticos/métodos , Coleta de Dados , Articulação do Joelho/cirurgia
19.
J Arthroplasty ; 38(4): 719-725, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36283515

RESUMO

BACKGROUND: The American Academy of Orthopaedic Surgeons guidelines report moderate evidence for cementing femoral stems for hip fractures, mainly derived from hemiarthroplasty literature. This is the first large, nonregistry study examining the influence of femoral fixation, implant type, patient characteristics, and radiographic factors on outcomes after total hip arthroplasty (THA) for acute femoral neck fractures. METHODS: A multicenter retrospective study was performed of 709 THA cases (199 cemented, 510 cementless) for femoral neck fractures from 2006 to 2020 at three large academic institutions. Demographics, perioperative characteristics, and radiographs were reviewed. Kaplan-Meier survivorship curves were generated for multiple outcomes. Univariate and multivariate analyses were performed with P ≤ .05 denoting significance. RESULTS: Cementless stems had a higher all-cause aseptic femoral revision rate (5.1 versus 0.5%, P = .002) and periprosthetic femoral fracture rate (4.3 versus 0%, P = .001). Each successive Dorr type had a higher fracture rate with cementless implants: 2.3%, 3.7%, and 15.9% in Dorr A, B, and C, respectively (P < .001). Logistic regression analyses confirmed that cementless stems (P = .02) and Dorr C bone (P = .001) are associated with periprosthetic fractures; collared implants and prophylactic cables did not protect against fractures. There was no difference in rates of dislocation, septic revision, or mortality between groups. CONCLUSION: Cementless stems during THA for femoral neck fractures have a higher aseptic femoral revision rate, specifically for periprosthetic fractures. Dorr C bone was particularly prone with an alarmingly high fracture rate. All fractures occurred in cementless cases, suggesting that cemented stems may minimize this complication. LEVEL OF EVIDENCE: III.


Assuntos
Artroplastia de Quadril , Fraturas do Fêmur , Fraturas do Colo Femoral , Prótese de Quadril , Fraturas Periprotéticas , Humanos , Artroplastia de Quadril/efeitos adversos , Fraturas Periprotéticas/cirurgia , Prótese de Quadril/efeitos adversos , Estudos Retrospectivos , Reoperação/efeitos adversos , Fatores de Risco , Desenho de Prótese , Fraturas do Colo Femoral/cirurgia , Fraturas do Fêmur/cirurgia
20.
J Surg Orthop Adv ; 32(2): 122-126, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37668651

RESUMO

The morbidity associated with the use of static non-articulating knee spacers for the treatment of periprosthetic joint infection (PJI) in challenging clinical scenarios has not been well described. From 2011-2019, 63 molded block static spacers were utilized at two academic institutions for the treatment of PJI with associated severe soft tissue compromise (59%), collateral ligament deficiency (49%), extensor mechanism compromise (48%), or type 3 bone defects (44%). Complications and outcomes were assessed. Complications with the use of static spacers were common and included further bone loss (46%), spacer migration (16%), extensor mechanism compromise (16%), cast or related soft tissue injuries (16%), fracture (13%), and spacer breakage (3%). Ultimately, 22% of patients underwent amputation. Patient variables such as age and body mass index were not associated with outcomes. Static knee spacers are associated with substantial morbidity in challenging clinical scenarios and alternatives may need to be considered. (Journal of Surgical Orthopaedic Advances 32(2):122-126, 2023).


Assuntos
Fraturas Ósseas , Articulação do Joelho , Humanos , Amputação Cirúrgica , Índice de Massa Corporal , Morbidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA