Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Nutr ; 153(4): 1253-1264, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36806449

RESUMO

BACKGROUND: Despite an increasing interest in vitamin D status, a reference range of the nutrient has not been fully established. This is partly due to a paucity of standardized measuring systems with high throughput. In addition, the range may vary by populations and may change with modernization of lifestyles. OBJECTIVES: This study aims to calculate the current reference concentration of 25-hydroxyvitamin D (25(OH)D) among healthy people living in an urban area in Japan. METHODS: A newly developed fully automated liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) system was used to measure serum 25(OH)D concentrations. Reproducibility was assessed by measuring standardized samples. Accuracy was validated by comparing with commercially available immunoassays. Then, mass screening was conducted targeting participants who received medical checkups in Tokyo from April 2019 to March 2020, and the reference ranges were calculated. RESULTS: The coefficients of variations of interoperator and interday reproducibility were 4.1%-8.5% and 3.7%-8.0% for 25-hydroxyvitamin D2 (25(OH)D2) and 4.7%-7.0% and 4.0%-6.9% for 25-hydroxyvitamine D3, respectively. The measured total 25(OH)D concentrations correlated well with those measured by immunoassays. In total, 5518 participants were measured for 25(OH)D concentrations, among whom 98% showed inadequate concentrations (<30 ng/mL). The reference ranges of total 25(OH)D for female, male, and total participants were 7-30 ng/mL, 5-27 ng/mL, and 6-29 ng/mL, respectively. After excluding those with abnormal renal and liver function, the range was 6-30 ng/mL. CONCLUSIONS: The high prevalence of vitamin D insufficiency among seemingly healthy population may be attributed to lifestyle characteristics of people living in urban areas of Japan, including spending less time outdoors and lower intake of traditional foods. Longitudinal follow-up and mass screenings targeting different population will help elucidate reasons for discrepancies between official guidelines and the observed concentrations, to which the well-validated measurement system is essential.


Assuntos
Cromatografia Líquida , População do Leste Asiático , Espectrometria de Massas em Tandem , Deficiência de Vitamina D , Vitamina D , Adulto , Feminino , Humanos , Masculino , 25-Hidroxivitamina D 2 , Calcifediol , Cromatografia Líquida/métodos , População do Leste Asiático/estatística & dados numéricos , Valores de Referência , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem/métodos , Vitamina D/sangue , Vitaminas , Deficiência de Vitamina D/sangue , Deficiência de Vitamina D/diagnóstico , Deficiência de Vitamina D/epidemiologia , Deficiência de Vitamina D/etiologia , Japão/epidemiologia
2.
Circ J ; 83(3): 672-680, 2019 02 25.
Artigo em Inglês | MEDLINE | ID: mdl-30700661

RESUMO

BACKGROUND: Patients with severe aortic stenosis (AS) and an extra-large annulus (ELA) area (>683 mm2) can rarely be treated by transcatheter aortic valve replacement (TAVR) because of the size limitation of the transcatheter heart valves. This study aimed to evaluate the feasibility of TAVR using a 29-mm SAPIEN3 (S3) valve in patients with ELA and S3-dimensions by post-procedural computed tomography (post-CT). Methods and Results: We included 261 patients undergoing TAVR using a 29-mm S3: 30 patients with ELA and 231 with non-ELA were identified. S3-dimensions were evaluated at the S3 inflow and annulus level by post-CT in 129 patients. The ELA group had a greater aortic annulus area measured by pre-procedural CT (737.3±54.7 vs. 578.4±41.9 mm2, P<0.0001), higher balloon inflation volume (36 vs. 33 mL, P<0.0001), a larger S3 area at inflow by post-CT (729.6±42.2 vs. 682.2±35.0 mm2, P<0.001), and a correlation between the inflation volume and S3 area (r=0.71, P=0.0005). No differences were observed between groups in paravalvular aortic regurgitation (PAR) ≥mild (43.3% vs. 27.6%, P=0.09), PAR ≥moderate (3.3% vs. 1.3%, P=0.39) or 1-year mortality (10.0% vs. 9.1%, P=0.87). CONCLUSIONS: TAVR using a 29-mm S3 with extra inflation of the delivery balloon can be considered as a treatment option for patients with severe AS and ELA.


Assuntos
Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Feminino , Humanos , Masculino , Tomografia Computadorizada Multidetectores , Desenho de Prótese , Resultado do Tratamento
3.
Circ J ; 82(10): 2655-2662, 2018 09 25.
Artigo em Inglês | MEDLINE | ID: mdl-30068793

RESUMO

BACKGROUND: Transcatheter aortic valve-in-valve (VIV) replacement within failed bioprosthetic surgical aortic valves is a feasible therapeutic option. However, data comparing the hemodynamic and clinical outcomes of VIV replacement with supra-annular self-expanding and balloon-expandable transcatheter heart valves (THV) are limited. Methods and Results: Outcomes of 40 and 95 patients treated with supra-annular self-expanding and balloon-expandable THV, respectively, were compared after propensity score matching, which yielded 37 pairs of patients with similar baseline characteristics. Hemodynamic and clinical outcomes were analyzed. Postprocedural mean gradient was significantly lower in the self-expanding THV group than in the balloon-expandable THV group (12.1±6.1 mmHg vs. 19.0±7.3 mmHg, P<0.001). The incidence of at least mild postprocedural aortic regurgitation (AR) was comparable between the self-expanding and balloon-expandable THV groups (21.6% vs. 10.8%, P=0.39). In the self-expanding THV group, the new-generation THV showed a trend towards a lower incidence of at least mild AR compared with the early-generation THV (12.5% vs. 38.5%, P=0.07). A similar trend was observed in the balloon-expandable THV group (4.2% vs. 23.1%, P=0.08). There was no significant difference between the self-expanding and balloon-expandable THV groups in the cumulative 2-year all-cause mortality rates (22.4% vs. 43.4%, log-rank P=0.26). CONCLUSIONS: The supra-annular self-expanding THV was associated with a lower postprocedural mean gradient compared with balloon-expandable THV in patients undergoing aortic VIV replacement.


Assuntos
Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica , Feminino , Próteses Valvulares Cardíacas , Hemodinâmica , Humanos , Masculino , Desenho de Prótese , Substituição da Valva Aórtica Transcateter/normas , Substituição da Valva Aórtica Transcateter/tendências , Resultado do Tratamento
4.
Circ J ; 81(7): 1036-1042, 2017 Jun 23.
Artigo em Inglês | MEDLINE | ID: mdl-28331113

RESUMO

BACKGROUND: The aim of this study was to determine the influence of an elliptic annulus on acute device success rates following self-expanding (SE) transcatheter aortic valve replacement (TAVR) vs. balloon-expandable (BE) TAVR.Methods and Results:Outcomes were assessed using Valve Academic Research Consortium-2 definitions. Aortic annulus ratio (AAR) was measured as short axis diameter/long axis diameter. Mean AAR was 0.81±0.06. Patients were therefore divided into 2 groups: AAR <0.82 and AAR ≥0.82. For circular annuli (AAR ≥0.82; 363 patients), high device success rates were achieved in both valve groups (SE valve, 90.5% vs. BE valve, 95.0%, P=0.14). Conversely, for AAR <0.82 (374 patients), SE valves had lower device success rates than BE valves (82.5% vs. 95.3%, P=0.002). For elliptic annuli, SE-TAVR was an independent predictor of unsuccessful device implantation (OR, 6.34, P<0.001). Nonetheless, increased oversizing of SE valves for elliptic annuli was associated with an exponential rise in device success (threshold ≥17.5%; area under the curve, 0.83) but not for BE-TAVR. Furthermore, optimally oversized SE valves and BE valves had a similarly high device success for elliptic annuli (SE valve, 96.2% vs. BE valve, 95.3%). CONCLUSIONS: For circular annuli, similarly high device success was achieved for the 2 valve types. Conversely, for elliptic annuli, SE valves had a lower device success than BE valves. Device success following optimal oversizing of SE valves, however, was similar to that for BE valves.


Assuntos
Valva Aórtica , Anuloplastia da Valva Cardíaca/métodos , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Feminino , Humanos , Masculino
5.
Catheter Cardiovasc Interv ; 87(6): 1111-7, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26354160

RESUMO

OBJECTIVES: The aim of this study was to assess the safety and efficacy of sheathless guide catheters in transradial percutaneous coronary intervention (PCI) for ST-segment elevation myocardial infarction (STEMI). BACKGROUND: Transradial PCI for STEMI offers significant clinical benefits, including a reduced incidence of vascular complications. As the size of the radial artery is small, the radial artery is frequently damaged in this procedure using large-bore catheters. A sheathless guide catheter offers a solution to this problem as it does not require an introducer sheath. However, the efficacy and safety of sheathless guide catheters remain to be fully determined in emergent transradial PCI for STEMI. METHODS: Data on consecutive STEMI patients undergoing primary PCI at the Sendai Kousei Hospital between September 2010 and May 2013 were analyzed. The primary endpoint was the rate of acute procedural success without access site crossover. Secondary endpoints included door-to-balloon time, fluoroscopy time, volume of contrast, and radial artery stenosis or occlusion rate. RESULTS: We conducted transradial PCI for 478 patients with STEMI using a sheathless guide catheter. Acute procedural success was achieved in 466 patients (97.5%). The median door-to-balloon time was 45 min (range, 15-317 min). The median fluoroscopy time was 16.4 min (range, 10-90 min). The median volume of contrast was 134 mL (range, 31-431 mL). Radial stenosis or occlusion developed in 14 (3.8%) of the 370 evaluable patients. CONCLUSIONS: This study showed that use of a sheathless guide catheter taking a transradial approach was effective and safe in primary PCI for STEMI. © 2015 Wiley Periodicals, Inc.


Assuntos
Cateteres Cardíacos , Eletrocardiografia , Intervenção Coronária Percutânea/instrumentação , Infarto do Miocárdio com Supradesnível do Segmento ST/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Angiografia Coronária , Desenho de Equipamento , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Artéria Radial , Estudos Retrospectivos , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico , Fatores de Tempo , Resultado do Tratamento
6.
Elife ; 122024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38650461

RESUMO

Transporter research primarily relies on the canonical substrates of well-established transporters. This approach has limitations when studying transporters for the low-abundant micromolecules, such as micronutrients, and may not reveal physiological functions of the transporters. While d-serine, a trace enantiomer of serine in the circulation, was discovered as an emerging biomarker of kidney function, its transport mechanisms in the periphery remain unknown. Here, using a multi-hierarchical approach from body fluids to molecules, combining multi-omics, cell-free synthetic biochemistry, and ex vivo transport analyses, we have identified two types of renal d-serine transport systems. We revealed that the small amino acid transporter ASCT2 serves as a d-serine transporter previously uncharacterized in the kidney and discovered d-serine as a non-canonical substrate of the sodium-coupled monocarboxylate transporters (SMCTs). These two systems are physiologically complementary, but ASCT2 dominates the role in the pathological condition. Our findings not only shed light on renal d-serine transport, but also clarify the importance of non-canonical substrate transport. This study provides a framework for investigating multiple transport systems of various trace micromolecules under physiological conditions and in multifactorial diseases.


Assuntos
Sistema ASC de Transporte de Aminoácidos , Transportadores de Ácidos Monocarboxílicos , Serina , Serina/metabolismo , Transportadores de Ácidos Monocarboxílicos/metabolismo , Sistema ASC de Transporte de Aminoácidos/metabolismo , Animais , Humanos , Rim/metabolismo , Camundongos , Sódio/metabolismo , Transporte Biológico , Masculino
7.
Sci Rep ; 14(1): 6479, 2024 03 18.
Artigo em Inglês | MEDLINE | ID: mdl-38499650

RESUMO

Intradialytic hypotension (IDH) is a common complication during hemodialysis that increases cardiovascular morbidity and mortality. Aortic stenosis (AS) is a cause of IDH. Transcatheter aortic valve replacement (TAVR) has become an established treatment for patients with severe AS. However, whether TAVR reduce the frequency of IDH has not been investigated. This study aims to verify the efficacy of TAVR for reduction of the frequency of IDH. Consecutive hemodialysis patients who underwent TAVR at Sendai Kosei Hospital from February 2021 to November 2021 with available records 1 month before and 3 months after TAVR were included in the study. IDH was defined as a decrease in systolic blood pressure by 20 mmHg or a decrease in the mean blood pressure by 10 mmHg associated with hypotensive symptoms or requiring intervention. Patients with ≥ 3 episodes of IDH in ten hemodialysis sessions comprised the IDH group. Overall, 18/41 (43.9%) patients were classified into the IDH group. In ten hemodialysis sessions, IDH events were observed 2.1, 4.3, and 0.4 times in the overall cohort, IDH group, and non-IDH group, respectively. After TAVR, the incidence of IDH decreased from 43.2 to 10.3% (p < 0.0001) and IDH improved significantly in 15 patients in the IDH group. The result suggested that severe AS was the major cause of IDH in this cohort, and TAVR may be an effective treatment option for reduction of the frequency of IDH in patients with severe AS.


Assuntos
Estenose da Valva Aórtica , Hipotensão , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Diálise Renal/efeitos adversos , Hipotensão/etiologia , Hipotensão/cirurgia , Fatores de Risco
8.
J Physiol Sci ; 74(1): 1, 2024 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-38166558

RESUMO

In humans, uric acid is an end-product of purine metabolism. Urate excretion from the human kidney is tightly regulated by reabsorption and secretion. At least eleven genes have been identified as human renal urate transporters. However, it remains unclear whether all renal tubular cells express the same set of urate transporters. Here, we show renal tubular cells are divided into three distinct cell populations for urate handling. Analysis of healthy human kidneys at single-cell resolution revealed that not all tubular cells expressed the same set of urate transporters. Only 32% of tubular cells were related to both reabsorption and secretion, while the remaining tubular cells were related to either reabsorption or secretion at 5% and 63%, respectively. These results provide physiological insight into the molecular function of the transporters and renal urate handling on single-cell units. Our findings suggest that three different cell populations cooperate to regulate urate excretion from the human kidney, and our proposed framework is a step forward in broadening the view from the molecular to the cellular level of transport capacity.


Assuntos
Rim , Ácido Úrico , Humanos , Ácido Úrico/metabolismo , Rim/metabolismo , Transporte Biológico
9.
J Clin Med ; 13(10)2024 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-38792317

RESUMO

Background: Despite the encouragement of early initiation and titration of guideline-directed medical therapy (GDMT) for the treatment of heart failure (HF), most patients do not receive an adequate type and dose of pharmacotherapy in the real world. Objectives: This study aimed to determine the efficacy of titrating composite GDMT in patients with HF with reduced and mildly reduced ejection fraction and to identify patient conditions that may benefit from titration of GDMT. Methods: This was a two-center, retrospective study of consecutive patients hospitalized with acute decompensated heart failure (ADHF). Patients were classified into two groups according to a scoring scale determined by combination and doses of four types of HF agents (ACEis/ARBs/ARNis, BBs, MRAs, and SGLT2is) at discharge. A score of 5 or greater was defined as titrated GDMT, and a score of 4 or less was regarded as sub-optimal medical therapy (MT). Results: A total of 979 ADHF patients were screened. After 553 patients were excluded based on exclusion criteria, 426 patients (90 patients in the titrated GDMT group and 336 patients in the sub-optimal MT group) were enrolled for the analysis. The median follow-up period was 612 (453-798) days. Following statistical adjustment using the propensity score weighting method, the 2-year composite endpoint (composite of cardiac death and HF rehospitalization) rate was significantly lower in the titrated GDMT group, at 19%, compared with the sub-optimal MT group: 31% (score 3-4 points) and 43% (score 0-2 points). Subgroup analysis indicated a marked benefit of titrated GDMT in particular patient subgroups: age < 80 years, BMI 19.0-24.9, eGFR > 20 mL/min/1.73 m2, and serum potassium level ≤ 5.5 mmol/L. Conclusions: Prompt initiation and dose adjustment of multiple HF medications, with careful monitoring of the patient's physiologic and laboratory values, is a prerequisite for improving the prognosis of patients with heart failure.

10.
J Cardiol ; 81(1): 97-104, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36114119

RESUMO

BACKGROUND: Coronary obstruction is a rare but catastrophic complication of transcatheter aortic valve replacement (TAVR) and occurs mostly at the left coronary artery (LCA) ostium. However, some patients do not show any clinical findings, and thus, its detection is sometimes difficult. The peak diastolic flow velocity in left main coronary artery (LM) was reportedly increased in significant stenosis lesions. We evaluated the effectiveness of measuring blood flow velocities in LM by transesophageal echocardiography (TEE) for the detection of LCA ostial obstruction during a TAVR procedure. METHODS: A total of 1105 consecutive patients who underwent TAVR in Sendai Kousei Hospital between September 2014 and December 2020 were enrolled. The LM blood flow velocity was measured at pre- and post-valve implantation. RESULTS: Among the 1105 patients, 9 had LCA ostial obstruction. The peak LM blood flow velocity at post-TAVR [0.90 (0.39-1.15) vs. 0.37 (0.28-0.50) m/s; p = 0.0046) was significantly higher in 9 patients who had LCA ostial obstruction, compared with the remaining 1096 patients who had not (controls), although no significant difference was observed before the TAVR procedures between the two groups. The post- to pre-TAVR LM flow velocity ratio [2.26 (1.31-3.42) vs. 1.06 (0.82-1.36); p = 0.0030] was also significantly higher in patients with LCA obstruction, compared to the controls. Furthermore, the post- to pre-TAVR LM blood flow velocity ratio was >2.0 in all six hemodynamically stable patients with LCA obstruction, whereas <2.0 in all three patients with LCA obstruction who showed hemodynamic collapse at post-TAVR procedure. CONCLUSION: Coronary blood flow velocity in LM significantly increased in hemodynamically stable LCA obstruction patients. The intraprocedural TEE measurement of the LM flow velocities would be potentially useful to detect asymptomatic and hemodynamically stable LCA ostial obstruction.


Assuntos
Estenose da Valva Aórtica , Oclusão Coronária , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Ecocardiografia Transesofagiana , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Oclusão Coronária/cirurgia , Ecocardiografia , Resultado do Tratamento , Valva Aórtica/cirurgia
11.
JACC Cardiovasc Interv ; 16(4): 415-425, 2023 02 27.
Artigo em Inglês | MEDLINE | ID: mdl-36858660

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR)-related coronary artery obstruction prediction remains unsatisfactory despite high mortality and novel preventive therapies. OBJECTIVES: This study sought to develop a predictive model for TAVR-related coronary obstruction in native aortic stenosis. METHODS: Preprocedure computed tomography and fluoroscopy images of patients in whom TAVR caused coronary artery obstruction were collected. Central laboratories made measurements, which were compared with unobstructed patients from a single-center database. A multivariate model was developed and validated against a 1:1 propensity-matched subselection of the unobstructed cohort. RESULTS: Sixty patients with angiographically confirmed coronary obstruction and 1,381 without obstruction were included. In-hospital death was higher in the obstruction cohort (26.7% vs 0.7%; P < 0.001). Annular area and perimeter, coronary height, sinus width, and sinotubular junction height and width were all significantly smaller in the obstructed cohort. Obstruction was most common on the left side (78.3%) and at the level of the coronary artery ostium (92.1%). Coronary artery height and sinus width, but not annulus area, were significant risk factors for obstruction by logistic regression but performed poorly in predicting obstruction. The new multivariate model (coronary obstruction IF cusp height > coronary height, AND virtual valve-to-coronary distance ≤4 mm OR culprit leaflet calcium volume >600 mm3) performed well, with an area under the curve of 0.93 (sensitivity = 0.93, specificity = 0.84) for the left coronary artery and 0.94 (sensitivity = 0.92, specificity = 0.96) for the right. CONCLUSIONS: A novel computed tomography-based multivariate prediction model that can be implemented routinely in real-world practice predicted coronary artery obstruction from TAVR in native aortic stenosis.


Assuntos
Estenose da Valva Aórtica , Oclusão Coronária , Substituição da Valva Aórtica Transcateter , Humanos , Mortalidade Hospitalar , Resultado do Tratamento , Coração
12.
Cardiovasc Interv Ther ; 37(4): 615-625, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35708855

RESUMO

Prosthesis-patient mismatch (PPM), first described in 1978, occurs when a prosthetic valve functions normally, but has an effective orifice area that is too small relative to the patient's body surface area. It results in residual left ventricular afterload and higher transvalvular pressure gradient, which has been considered to impair prognosis. PPM following surgical aortic replacement is reportedly associated with worse clinical outcomes, such as high mortality. However, the impact of PPM on clinical outcomes after transcatheter aortic valve implantation (TAVI) remains unclear. There is conflicting evidence on the impact of PPM following TAVI due to differences across studies in terms of follow-up period, methods, patient populations, and type of bioprosthetic valve. The present review summarizes the most recent evidence on PPM after TAVI.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Desenho de Prótese , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
13.
Tex Heart Inst J ; 49(5)2022 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-36223245

RESUMO

Anastomotic complications of the coronary arteries were observed in approximately 5% of patients undergoing Bentall-type surgery. Given the high surgical risk of reoperation, percutaneous coronary intervention could be a treatment for anastomotic complications but is challenging because of the complicated anatomy after Bentall-type surgery. Here, a 70-year-old man underwent a Bentall operation during which the left main coronary artery was accidentally injured. Therefore, coronary artery bypass using a saphenous vein graft was performed. The saphenous vein graft was anastomosed from the right side of the aortic graft to the left main coronary artery. Three years later, the patient presented with an anterior non-ST-segment elevation myocardial infarction. Because his unusual anatomy, the saphenous vein graft could not be cannulated with diagnostic catheters, even after perusing the surgical record of the Bentall surgery. Subsequently, coronary computed tomography angiography was performed. Three-dimensional reconstructed images visualized the positional relationship between the saphenous vein graft and anatomical landmarks, such as the implanted surgical valve prosthesis. The angiogram angle was adjusted using these landmarks and projection angles estimated by the images. Then, the ASAHI Hyperion Judkins right 4 catheter could be easily inserted, and percutaneous coronary intervention was successfully performed. Three-dimensional reconstruction images were useful for performing percutaneous coronary intervention by aiding in the identification of the anatomic location of the saphenous vein graft and the positional relationship between the saphenous vein graft and anatomic landmarks. In patients with unusual anatomy, as in this case, coronary computed tomography angiography should be strongly considered.


Assuntos
Infarto do Miocárdio sem Supradesnível do Segmento ST , Intervenção Coronária Percutânea , Idoso , Angiografia por Tomografia Computadorizada , Angiografia Coronária , Humanos , Imageamento Tridimensional , Masculino , Intervenção Coronária Percutânea/efeitos adversos , Veia Safena/diagnóstico por imagem , Veia Safena/transplante
14.
J Cardiol ; 80(3): 190-196, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35469714

RESUMO

BACKGROUND: In transcatheter aortic valve replacement (TAVR) using SAPIEN 3 (S3) (Edwards Lifesciences, Irvine, CA, USA), some clinicians decrease or increase the delivery balloon volume (VOL) when deploying S3 or conducting post-dilatation. However, the effects of controlling VOL on transcatheter heart valve diameter (THVD) and valve function remain unclear. We assessed associations among VOL, THVD, and effective orifice area (EOA) of S3. METHODS: We enrolled patients undergoing TAVR using 23- and 26-mm S3 in Sendai Kousei Hospital between 2017 and 2019. VOL was controlled based on preprocedural computed tomography and intraprocedural transesophageal echocardiography (TEE). THVD were defined as the diameters of transcatheter heart valve at mid-level measured by TEE. RESULTS: In enrolled 332 patients (23-mm, n = 188; 26-mm, n = 144), one (0.3%) and two (0.6%) developed annulus rupture and moderate/severe paravalvular leak, respectively. VOL at deployment was positively correlated with THVD on deployment (23-mm, r = 0.44, p < 0.001; 26-mm, r = 0.57, p < 0.001) and EOA (23-mm, r = 0.23, p = 0.0019; 26-mm, r = 0.22, p = 0.0094). In multiple regression analyses, VOL and post-dilatation were significant determinants of THVD, although aortic annulus area, calcium volume, and pre-dilatation were not. The areas under the receiver operating characteristic curve that were used to evaluate the accuracy of the index obtained by dividing THVD by body surface area (indexed THVD) to predict patient-prosthesis mismatch (PPM) were 0.744 and 0.811 in the 23- and 26-mm cohorts, respectively. A cut-off indexed THVD of ≤11.5 and 12.1 mm/m2 well predicted PPM (23-mm, odds ratio, 5.20; 95% confidence interval, 1.33-20.3; 26-mm, odds ratio 14.1, 95% confidence interval 2.40-81.0). CONCLUSION: VOL was positively correlated with THVD and EOA. Smaller indexed THVD was associated with a higher incidence of PPM. Controlling VOL under on-site THVD evaluation may be useful in reducing the PPM incidence.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Desenho de Prótese , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
16.
Open Heart ; 8(1)2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33737333

RESUMO

BACKGROUND: The balloon-expandable SAPIEN 3 (S3) is superior to the older-generation balloon-expandable SAPIEN XT (XT) in a lower incidence of paravalvular aortic regurgitation, lower complication rates and better survival in transcatheter aortic valve implantation (TAVI). However, prosthesis-patient mismatch (PPM) more frequently occurs in S3 than XT. Further, little information is available on PPM after TAVI using S3 in Asians. This study aims to determine the incidence and predictors of PPM in S3 by focusing on the difference between S3 and XT using data from a Japanese multicentre registry. METHODS: From the Optimised transCathEter vAlvular iNtervention-TAVI (OCEAN-TAVI) registry, 2134 patients undergoing TAVI using S3 or XT were included. PPM was defined as moderate if ≧0.65 but ≦0.85 cm2/m2 or severe if <0.65 cm2/m2 at the indexed effective orifice area by postprocedural echocardiography. RESULTS: The incidence of moderate and severe PPM in S3 was 13.3% and 1.3%, respectively. The 20 mm transcatheter heart valve (THV) was more frequently used in S3 than XT (7.4% vs 2.4%, p<0.0001). PPM was more frequently observed in S3 than XT (14.7% vs 8.8%, p<0.0001). Multivariate logistic regression analysis revealed S3 predicted PPM (OR 1.92 (95% CI 1.35 to 2.74), p=0.0003). The mutual predictors for PPM between S3 and XT were younger age, larger body surface area, smaller aortic valve area, no balloon postdilatation and the use of 20 mm and 23 mm THV. When comparing 23 mm, 26 mm and 29 mm S3, the ORs of 20 mm S3 were 5.67 (95% CI 2.88 to 11.12), 19.24 (95% CI 8.13 to 46.86) and 51.03 (95% CI 12.28 to 280.77), respectively. CONCLUSIONS: The incidence of PPM after TAVI using S3 was 14.6% overall in this Asian population. PPM was more frequently observed in S3 than XT. A considerable number of patients were treated by the 20 mm S3 in an Asian cohort. The 20 mm THV was identified as a strong predictor for PPM.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Bioprótese/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos , Sistema de Registros , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/diagnóstico , Insuficiência da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/mortalidade , Ecocardiografia , Seguimentos , Humanos , Incidência , Japão/epidemiologia , Estudos Prospectivos , Desenho de Prótese , Taxa de Sobrevida/tendências , Resultado do Tratamento
17.
Eur Heart J Case Rep ; 4(3): 1-6, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32617485

RESUMO

BACKGROUND: Limited research has been conducted on the surgical management of the aortic valve in congenitally corrected transposition of great arteries (ccTGA) and to our knowledge there have been no reports on the treatment of bicuspid aortic regurgitation (AR) in ccTGA. We report on a ccTGA patient with bicuspid AR and systemic right ventricule (SRV) dysfunction who underwent transcatheter aortic valve replacement (TAVR). CASE SUMMARY: A 17-year-old male with a history of ccTGA and cerebral palsy diagnosed at birth presented with heart failure. During childhood, he did not experience any heart failure symptoms, however, secondary to progressive bicuspid AR he experienced worsening SRV dysfunction beginning at 15-year-old. Echocardiography showed reduced SRV ejection fraction and severe bicuspid AR. The heart team, including a cardiac surgeon and paediatric cardiologist, discussed the treatment strategies and decided to proceed with TAVR as surgical aortic valve replacement was deemed high risk. TAVR was performed with the 34 mm Evolut R (Medtronic, Minneapolis, MN, USA). Post-operative echocardiography showed severe paravalvular leak (PVL). Therefore, valve-in-valve TAVR using a 29 mm Edwards SAPIEN 3 (Edwards Lifesciences, Irvine, CA, USA) was performed on post-operative Day 2 for PVL reduction. Following second procedure, PVL was significantly improved. The patient was discharged in stable condition. DISCUSSION: This is the first case wherein TAVR was performed for bicuspid AR in a patient with ccTGA. With appropriate preparation and planning and a collaborative multi-disciplinary team approach, TAVR can be a treatment option for severe AR in patients with ccTGA at high risk for surgery.

18.
JACC Cardiovasc Interv ; 13(13): 1544-1553, 2020 07 13.
Artigo em Inglês | MEDLINE | ID: mdl-32646695

RESUMO

OBJECTIVES: The aim of this study was to investigate the incidence, characteristics, hemodynamic conditions, and clinical significance of right-to-left (R-L) shunt through an iatrogenic atrial septal defect (iASD) after the MitraClip procedure. BACKGROUND: R-L shunt through an iASD after the MitraClip procedure has not been well investigated. METHODS: From 2014 to 2017, 385 consecutive patients with mitral regurgitation underwent the MitraClip procedure. iASD was assessed using intraprocedural transesophageal echocardiography. Right and left heart catheterization was used to assess the hemodynamic status of patients. All patients provided written informed consent for the procedure. All data for this study were collected from an established interventional cardiology laboratory database approved by the Cedars-Sinai Medical Center Institutional Review Board. RESULTS: R-L shunt was observed in 20 patients (5%). In 7 of these patients (35%), R-L shunt was accompanied by acute deoxygenation. Prevalence of severe tricuspid regurgitation (55% vs. 20%; p = 0.001), serum B-type natriuretic peptide (664 pg/ml [434 to 1,169 pg/ml] vs. 400 pg/ml [195 to 699 pg/ml]; p = 0.006), mean pulmonary artery pressure (38 mm Hg [34 to 45 mm Hg] vs. 29 mm Hg [22 to 37 mm Hg]; p < 0.001), and right atrial pressure (19 mm Hg [13 to 20 mm Hg] vs. 10 mm Hg [7 to 14 mm Hg]; p < 0.001) were significantly higher in patients with R-L shunt than in those with left-to-right shunt. Patients with R-L shunt also showed a more prominent reduction in the left atrial V-wave and mean pressure from baseline to post-procedure compared with those with left-to-right shunt (-22.8 ± 2.6 mm Hg vs. -11.8 ± 0.9 mm Hg [p = 0.002] and -7.9 ± 0.8 mm Hg vs. -4.0 ± 0.4 mm Hg [p = 0.003], respectively). CONCLUSIONS: R-L shunt through an iASD was observed in 5% of patients who underwent the MitraClip procedure and in one-third of patients with R-L shunt presented acute deoxygenation. Elevated right atrial pressure concomitant with pulmonary hypertension and significant reduction in left atrial pressure after MitraClip deployment were associated with R-L shunt.


Assuntos
Comunicação Interatrial/etiologia , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Hemodinâmica , Doença Iatrogênica , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Idoso , Idoso de 80 Anos ou mais , Feminino , Comunicação Interatrial/diagnóstico por imagem , Comunicação Interatrial/fisiopatologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Masculino , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/fisiopatologia , Desenho de Prótese , Estudos Retrospectivos , Resultado do Tratamento
19.
Open Heart ; 7(2)2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33318151

RESUMO

OBJECTIVES: Patients' backgrounds and clinical outcomes in urgent/emergent/salvage transcatheter aortic valve replacement (Em-TAVR) remain unclear. We investigated patient characteristics and the mortality in Em-TAVR and the predictors for the need for Em-TAVR. METHODS: We consecutively enrolled 1613 patients undergoing TAVR for severe aortic stenosis between October 2013 and July 2016 from the Optimised transCathEter vAlvular interventioN (OCEAN)-transcatheter aortic valve implantation (TAVI) registry. The urgency was based on the European System for Cardiac Operative Risk Evaluation II. Urgent, emergent or salvage were included with the Em-TAVR group and elective with the El-TAVR group. RESULTS: Em-TAVR was observed in 87 (5.4%) patients. A higher Clinical Frailty Scale (CFS), peripheral artery disease (PAD), hypoalbuminaemia, reduced left ventricular ejection fraction (LVEF) and preoperative at least moderate mitral regurgitation (MR) predicted the need for the Em-TAVR by the multivariate logistic regression analysis. The Em-TAVR group had the higher Society of Thoracic Surgeons Score (13.7 (IQR 8.2-21.0) vs 6.5 (IQR 4.6-9.2); p<0.001) and higher 30-day mortality (9.2% vs 1.3%; p<0.001) than the El-TAVR group. Accordingly, Kaplan-Meier analysis showed that the cumulative mortality was higher in the Em-TAVR group than that in the El-TAVR group (log-rank; p<0.001). However, Em-TAVR did not predict mortality in the multivariate Cox regression analysis. CONCLUSIONS: Em-TAVR was performed in 5.4% of patients. Higher CFS, PAD, hypoalbuminaemia, reduced LVEF and preprocedural MR predicted the need for Em-TAVR. Em-TAVR was not a predictor for mortality in the multivariate analysis, suggesting that it is a reasonable treatment option.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Sistema de Registros , Substituição da Valva Aórtica Transcateter/mortalidade , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/mortalidade , Feminino , Humanos , Japão/epidemiologia , Masculino , Estudos Prospectivos , Fatores de Risco , Índice de Gravidade de Doença , Taxa de Sobrevida/tendências
20.
J Invasive Cardiol ; 32(2): E18-E26, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32005786

RESUMO

OBJECTIVES: Little information is available on computed tomography (CT)-based predictors of stroke related to transcatheter aortic valve replacement (TAVR). The objective of this study was to determine whether anatomical features of the aortic valve and aorta visualized by CT are predictive parameters of stroke. METHODS: The study included 1270 patients who underwent preprocedural contrast-enhanced CT assessment and TAVR for severe aortic valve stenosis. Twenty-six patients (2.5%) who developed acute strokes that occurred within 48 hours after TAVR and 104 matched patients without strokes were identified, using 1:4 propensity-score matching. The degree of hypoattenuation in the aortic valve leaflets, calcium volume of the aortic valve, and plaque thickness in the aortic wall (the ascending aorta, aortic arch, and descending thoracic aorta) were assessed. RESULTS: There were no differences between the two groups in the degree of hypoattenuation in the aortic valve leaflets and calcium volume of the aortic valve. The plaque thickness of the aortic arch and descending aorta were greater in the stroke group than in the non-stroke group: aortic arch, 2.4 mm (IQR, 1.3-2.8 mm) vs 1.8 mm (IQR, 1.4-2.2 mm), respectively (P<.01); and descending aorta, 2.9 mm (IQR, 2.1-4.2 mm) vs 2.8 mm (IQR, 2.1-3.6 mm); respectively (P=.049). CONCLUSION: Aortic wall plaque thickness measured by contrast-enhanced CT might be a predictive parameter of strokes that occur within 48 hours after TAVR.


Assuntos
Aorta , Estenose da Valva Aórtica , Valva Aórtica , Placa Aterosclerótica , Complicações Pós-Operatórias , Acidente Vascular Cerebral , Tomografia Computadorizada por Raios X/métodos , Substituição da Valva Aórtica Transcateter , Idoso , Aorta/diagnóstico por imagem , Aorta/patologia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/patologia , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Feminino , Humanos , Masculino , Placa Aterosclerótica/diagnóstico por imagem , Placa Aterosclerótica/patologia , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/prevenção & controle , Valor Preditivo dos Testes , Cuidados Pré-Operatórios/métodos , Risco Ajustado/métodos , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA