1.
Circulation ; 149(5): 379-390, 2024 01 30.
Artigo em Inglês | MEDLINE | ID: mdl-37950738

RESUMO

BACKGROUND: Left bundle branch area pacing (LBBAP) may be associated with greater improvement in left ventricular ejection fraction and reduction in death or heart failure hospitalization compared with biventricular pacing (BVP) in patients requiring cardiac resynchronization therapy. We sought to compare the occurrence of sustained ventricular tachycardia (VT) or ventricular fibrillation (VF) and new-onset atrial fibrillation (AF) in patients undergoing BVP and LBBAP. METHODS: The I-CLAS study (International Collaborative LBBAP Study) included patients with left ventricular ejection fraction ≤35% who underwent BVP or LBBAP for cardiac resynchronization therapy between January 2018 and June 2022 at 15 centers. We performed propensity score-matched analysis of LBBAP and BVP in a 1:1 ratio. We assessed the incidence of VT/VF and new-onset AF among patients with no history of AF. Time to sustained VT/VF and time to new-onset AF was analyzed using the Cox proportional hazards survival model. RESULTS: Among 1778 patients undergoing cardiac resynchronization therapy (BVP, 981; LBBAP, 797), there were 1414 propensity score-matched patients (propensity score-matched BVP, 707; propensity score-matched LBBAP, 707). The occurrence of VT/VF was significantly lower with LBBAP compared with BVP (4.2% versus 9.3%; hazard ratio, 0.46 [95% CI, 0.29-0.74]; P<0.001). The incidence of VT storm (>3 episodes in 24 hours) was also significantly lower with LBBAP compared with BVP (0.8% versus 2.5%; P=0.013). Among 299 patients with cardiac resynchronization therapy pacemakers (BVP, 111; LBBAP, 188), VT/VF occurred in 8 patients in the BVP group versus none in the LBBAP group (7.2% versus 0%; P<0.001). In 1194 patients with no history of VT/VF or antiarrhythmic therapy (BVP, 591; LBBAP, 603), the occurrence of VT/VF was significantly lower with LBBAP than with BVP (3.2% versus 7.3%; hazard ratio, 0.46 [95% CI, 0.26-0.81]; P=0.007). Among patients with no history of AF (n=890), the occurrence of new-onset AF >30 s was significantly lower with LBBAP than with BVP (2.8% versus 6.6%; hazard ratio, 0.34 [95% CI, 0.16-0.73]; P=0.008). The incidence of AF lasting >24 hours was also significantly lower with LBBAP than with BVP (0.7% versus 2.9%; P=0.015). CONCLUSIONS: LBBAP was associated with a lower incidence of sustained VT/VF and new-onset AF compared with BVP. This difference remained significant after adjustment for differences in baseline characteristics between patients with BVP and LBBAP. Physiological resynchronization by LBBAP may be associated with lower risk of arrhythmias compared with BVP.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Taquicardia Ventricular , Humanos , Terapia de Ressincronização Cardíaca/efeitos adversos , Volume Sistólico , Função Ventricular Esquerda , Resultado do Tratamento , Taquicardia Ventricular/epidemiologia , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/terapia , Fibrilação Ventricular/epidemiologia , Fibrilação Ventricular/etiologia , Fibrilação Ventricular/terapia , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/terapia , Eletrocardiografia
2.
Europace ; 26(1)2023 12 28.
Artigo em Inglês | MEDLINE | ID: mdl-38042980

RESUMO

AIMS: Autothreshold algorithms enable remote monitoring of patients with conventional pacing, but there is limited information on their performance in left bundle branch pacing (LBBP). Our objective was to analyse the behaviour of the autothreshold algorithm in LBBP and compare it with conventional pacing and manual thresholds during initial device programming (acute phase), after 1-7 days (subacute), and 1-3 months later (chronic). METHODS AND RESULTS: A prospective, non-randomized, single-centre comparative study was conducted. Consecutive patients with indication for cardiac pacing were enrolled. Implants were performed in the left bundle branch area or the right ventricle endocardium at the discretion of the operator. Left bundle branch pacing was determined according to published criteria. Autothreshold algorithm was activated in both groups whenever allowed by the device. Seventy-five patients were included, with 50 undergoing LBBP and 25 receiving conventional pacing. Activation of the autothreshold algorithm was more feasible in later phases, showing a favourable trend towards bipolar pacing. Failures in algorithm activation were primarily due to insufficient safety margins (82.8% in LBBP and 90% in conventional pacing). The remainder was attributed to atrial tachyarrhythmias (10.3% and 10%, respectively) and electrical noise (the remaining 6.9% in the LBBP group). In the LBBP group, there were not statistically significant differences between manual and automatic thresholds, and both remained stable during follow-up (mean increase of 0.50 V). CONCLUSION: The autothreshold algorithm is feasible in LBBP, with a favourable trend towards bipolar pacing. Automatic thresholds are similar to manual in patients with LBBP, and they remain stable during follow-up.


Assuntos
Fascículo Atrioventricular , Bloqueio de Ramo , Humanos , Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/métodos , Estudos de Viabilidade , Estudos Prospectivos , Eletrocardiografia/métodos , Resultado do Tratamento
3.
Europace ; 25(12)2023 12 06.
Artigo em Inglês | MEDLINE | ID: mdl-38019960

RESUMO

AIMS: The compatibility of cardiac pacing with the presence of a subcutaneous implantable cardioverter-defibrillator (S-ICD) has been investigated, but S-ICD screening test results have not been compared among different pacing sites. The objective was to compare S-ICD screening results among different cardiac pacing sites and to assess the electrocardiographic predictors of success. METHODS AND RESULTS: This prospective single-centre study conducted automated S-ICD screening in 102 carriers of cardiac pacing devices in conduction system (CSP), biventricular (BVP), right ventricular outflow tract (RVOT), or right ventricular apex (RVA) pacing sites. The study included 102 patients: 40 with CSP (20 left bundle pacing and 20 His bundle pacing), 21 with BVP, and 20 and 21 with RVOT and RVA pacing, respectively. The percentage of positive screenings was significantly higher for CSP (97.5%) than for the other patient groups (BVP 71.4%, RVOT 70%, and RVA 19%). In multivariate analysis, positive screening was associated with a narrower QRS (OR 0.95 [0.92-0.98] P = 0.001) and higher R/T ratio in precordial leads (1.76 [1.18-2.61]). CONCLUSION: A higher S-ICD eligibility rate of cardiac pacing device carriers was obtained in CSP than in conventional pacing (RVA or RVOT) or BVP. The presence of narrower paced QRS width and paced corrected QT interval and of higher R/T ratio in precordial and limb leads are electrocardiographic predictors of a positive response to screening.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos , Estudos Prospectivos , Estimulação Cardíaca Artificial/métodos , Cardioversão Elétrica/métodos , Eletrocardiografia , Resultado do Tratamento
4.
Indian Pacing Electrophysiol J ; 21(1): 51-53, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33249128

RESUMO

Ablation of macroreentrant atrial tachycardia in patients with mechanical prosthetic valves represents a challenge for electrophysiologists, because of the complexity of the procedure and the potential complications. Moreover, the need for fluoroscopy in this type of procedure is greater, due to the risk of interference between the prosthetic valve and the ablation or mapping catheter. We present two cases of patients with mechanical prosthetic valves and atrial flutter who underwent successful ablation with no complications using the CartoUnivu™ tool, which integrates the electroanatomical map and the fluoroscopy image.

6.
JACC Clin Electrophysiol ; 10(1): 96-105, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37737782

RESUMO

BACKGROUND: Cardiac resynchronization therapy (CRT) using biventricular pacing (BVP) has been associated with greater clinical improvement in women than men. Recently, left bundle branch area pacing (LBBAP) has been shown to be an alternative form of CRT. OBJECTIVES: The purpose of this study was to investigate sex-specific outcomes for death and heart failure events in a large, international, multicenter, cohort of patients undergoing CRT with BVP or LBBAP. METHODS: In this international study of 1,778 patients (575 female and 1203 male), sex-specific survival analysis was performed to compare the effect of LBBAP-CRT relative to BVP-CRT on the combined endpoint of death or heart failure hospitalization (HFH), and secondary endpoints of HFH only, and death alone. RESULTS: Female patients were more likely to have nonischemic cardiomyopathy and left bundle branch block (LBBB) and less likely to have hypertension, diabetes, or coronary artery disease than were male patients. Overall, female patients had a better result with LBBAP compared with BVP than did male patients, with a significant 36% reduction in death or HFH (HR: 0.64; 95% CI: 0.43 to 0.97; P = 0.03) and a significant 60% reduction in HFH alone (HR: 0.4; 95% CI: 0.24 to 0.69, P < 0.01). Women had a greater reduction in death or HFH among those with nonischemic cardiomyopathy (HR: 0.45 95% CI: 0.26 to 0.79; P < 0.01) and LBBB (HR: 0.49; 95% CI: 0.27 to 0.87; P < 0.01). Sex-specific echocardiographic outcomes were better in women than in men. CONCLUSIONS: Women obtained significantly greater reductions in the combined endpoint of death or HFH (primarily driven by reduction in HFH) with LBBAP compared with BVP among patients requiring CRT than did men.


Assuntos
Terapia de Ressincronização Cardíaca , Cardiomiopatias , Insuficiência Cardíaca , Humanos , Masculino , Feminino , Terapia de Ressincronização Cardíaca/métodos , Resultado do Tratamento , Bloqueio de Ramo , Cardiomiopatias/terapia
7.
Heart Rhythm ; 20(12): 1617-1625, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37348800

RESUMO

BACKGROUND: Conduction system pacing (CSP), including both left bundle branch area pacing (LBBAP) and His-bundle pacing (HBP) has been proposed as an alternative therapy option for patients with indication for cardiac pacing to treat bradycardia or heart failure. OBJECTIVE: The purpose of this study was to evaluate implant success, safety, and electrical performances of HBP and LBBAP in the multinational Physiological Pacing Registry. METHODS: The international prospective observational registry included 44 sites from 16 countries globally between November 2018 and May 2021. RESULTS: Of 870 subjects enrolled, CSP lead implantation was attempted in 849 patients. Subjects with successful CSP lead implantation were followed for 6 months (5 ± 2 months). CSP lead implantation was successful in 768 patients (90.4%). Implant success was 95.2% (239/251) for LBBAP and 88.5% (529/598) for HBP (P = .002). Procedural duration and fluoroscopy duration were comparable between LBBAP and HBP (P = .537). Capture threshold at implant was 0.69 ± 0.39 V at 0.46 ± 0.15 ms in LBBAP and 1.44 ± 1.03 V at 0.71 ± 0.33 ms in HBP (P <.001). Capture threshold at 6 months was 0.79 ± 0.33 V at 0.44 ± 0.13 ms in LBBAP and 1.59 ± 0.97 V at 0.67 ± 0.31 ms in HBP (P <.001). Pacing threshold rise ≥1 V was observed at 6 months in 3 of 208 (1.4%) of LBBAP and 55 of 418 (13.2%) of HBP (P <.001). Serious adverse events related to implant procedure or CSP lead occurred in 5 of 251 (2.0%) with LBBAP and 25 of 598 (4.2%) with HBP (P = .115). CONCLUSION: This large prospective multicenter study demonstrates that CSP is technically feasible in most patients with relatively higher implant success and suggests that, with current technology, LBBAP may have better pacing parameters than HBP.


Assuntos
Fascículo Atrioventricular , Estimulação Cardíaca Artificial , Humanos , Estudos Prospectivos , Estimulação Cardíaca Artificial/métodos , Eletrocardiografia/métodos , Doença do Sistema de Condução Cardíaco/etiologia , Sistema de Registros , Resultado do Tratamento
8.
J Am Coll Cardiol ; 82(3): 228-241, 2023 07 18.
Artigo em Inglês | MEDLINE | ID: mdl-37220862

RESUMO

BACKGROUND: Cardiac resynchronization therapy (CRT) with biventricular pacing (BVP) is a well established therapy in patients with reduced left ventricular ejection fraction (LVEF), heart failure, and wide QRS or expected frequent ventricular pacing. Left bundle branch area pacing (LBBAP) has recently been shown to be a safe alternative to BVP. OBJECTIVES: The aim of this study was to compare the clinical outcomes between BVP and LBBAP among patients undergoing CRT. METHODS: This observational study included patients with LVEF ≤35% who underwent BVP or LBBAP for the first time for Class I or II indications for CRT from January 2018 to June 2022 at 15 international centers. The primary outcome was the composite endpoint of time to death or heart failure hospitalization (HFH). Secondary outcomes included endpoints of death, HFH, and echocardiographic changes. RESULTS: A total of 1,778 patients met inclusion criteria: 981 BVP, 797 LBBAP. The mean age was 69 ± 12 years, 32% were female, 48% had coronary artery disease, and mean LVEF was 27% ± 6%. Paced QRS duration in LBBAP was significantly narrower than baseline (128 ± 19 ms vs 161 ± 28 ms; P < 0.001) and significantly narrower compared to BVP (144 ± 23 ms; P < 0.001). Following CRT, LVEF improved from 27% ± 6% to 41% ± 13% (P < 0.001) with LBBAP compared with an increase from 27% ± 7% to 37% ± 12% (P < 0.001) with BVP, with significantly greater change from baseline with LBBAP (13% ± 12% vs 10% ± 12%; P < 0.001). On multivariable regression analysis, the primary outcome was significantly reduced with LBBAP compared with BVP (20.8% vs 28%; HR: 1.495; 95% CI: 1.213-1.842; P < 0.001). CONCLUSIONS: LBBAP improved clinical outcomes compared with BVP in patients with CRT indications and may be a reasonable alternative to BVP.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Masculino , Volume Sistólico , Eletrocardiografia , Função Ventricular Esquerda , Resultado do Tratamento , Insuficiência Cardíaca/terapia
9.
Rev Esp Cardiol (Engl Ed) ; 75(2): 166-173, 2022 Feb.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-33741288

RESUMO

INTRODUCTION AND OBJECTIVES: Ionizing radiation exposure in catheter ablation procedures carries health risks, especially in pediatric patients. Our aim was to compare the safety and efficacy of catheter ablation guided by a nonfluoroscopic intracardiac navigation system (NFINS) with those of an exclusively fluoroscopy-guided approach in pediatric patients. METHODS: We analyzed catheter ablation results in pediatric patients with high-risk accessory pathways or supraventricular tachycardia referred to our center during a 6-year period. We compared fluoroscopy-guided procedures (group A) with NFINS guided procedures (group B). RESULTS: We analyzed 120 catheter ablation procedures in 110 pediatric patients (11±3.2 years, 70% male); there were 62 procedures in group A and 58 in group B. We found no significant differences between the 2 groups in procedure success (95% group A vs 93.5% group B; P=.53), complications (1.7% vs 1.6%; P=.23), or recurrences (7.3% vs 6.9%; P = .61). However, fluoroscopy time (median 1.1minutes vs 12minutes; P <.0005) and ablation time (median 96.5seconds vs 133.5seconds; P=.03) were lower in group B. The presence of structural heart disease was independently associated with recurrence (P=.03). CONCLUSIONS: The use of NFINS to guide catheter ablation procedures in pediatric patients reduces radiation exposure time. Its widespread use in pediatric ablations could decrease the risk of ionizing radiation.


Assuntos
Feixe Acessório Atrioventricular , Ablação por Cateter , Taquicardia Supraventricular , Criança , Feminino , Fluoroscopia , Humanos , Masculino , Taquicardia Supraventricular/cirurgia , Resultado do Tratamento
10.
Heart Rhythm ; 19(8): 1272-1280, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35504539

RESUMO

BACKGROUND: Cardiac resynchronization therapy (CRT) using biventricular pacing (BVP) is effective in patients with heart failure, left bundle branch block (LBBB), and reduced left ventricular function. Left bundle branch area pacing (LBBAP) has been reported as an alternative option for CRT. OBJECTIVE: The purpose of this study was to assess the feasibility and outcomes of LBBAP in patients who failed conventional BVP because of coronary venous (CV) lead complications or who were nonresponders to BVP. METHODS: At 16 international centers, LBBAP was attempted in patients with conventional CRT indication who failed BVP because of CV lead complications or lack of therapeutic response to BVP. Heart failure hospitalization (HFH) and death, echocardiographic outcomes, procedural data, pacing parameters, and lead complications including CV lead failure are reported. RESULTS: LBBAP was successfully performed in 200 patients (CV lead failures 156; nonresponders 44) (age 68 ± 11 years; female 35%; LBBB 55%; right ventricular pacing 23%; ischemic cardiomyopathy 28%; nonischemic cardiomyopathy 63%; left ventricular ejection fraction [LVEF] ≤35% in 80%). Procedural duration was 119.5 ± 59.6 minutes, and fluoroscopy duration was 25.7 ± 18.5 minutes. LBBAP threshold and R-wave amplitudes were 0.68 ± 0.35 V @ 0.45 ms and 10.4 ± 5 mV at implant, respectively, and remained stable during mean follow-up of 12 ± 10.1 months. LBBAP resulted in significant QRS narrowing from 170 ± 28 ms to 139 ± 25 ms (P <.001) with V6 R-wave peak times of 85 ± 17 ms. LVEF improved from 29% ± 10% at baseline to 40% ± 12% (P <.001) during follow-up. The risk of death or HFH was lower in those with CV lead failure than in nonresponders (hazard ratio 0.357; 95% confidence interval 0.168-0.756; P = .007) CONCLUSION: LBBAP is a viable alternative to CRT in patients who failed conventional BVP due to CV lead failure or who were nonresponders.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Idoso , Arritmias Cardíacas/terapia , Fascículo Atrioventricular , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/etiologia , Bloqueio de Ramo/terapia , Estimulação Cardíaca Artificial/métodos , Terapia de Ressincronização Cardíaca/métodos , Eletrocardiografia/métodos , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/terapia , Humanos , Pessoa de Meia-Idade , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda/fisiologia
11.
Heart Rhythm O2 ; 3(4): 358-367, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36097454

RESUMO

Background: Cardiac resynchronization therapy (CRT) using biventricular pacing has limited efficacy in patients with heart failure (HF) and right bundle branch block (RBBB). Left bundle branch area pacing (LBBAP) is a novel physiologic pacing option. Objective: The aim of the study was to assess the feasibility and outcomes of LBBAP in HF patients with RBBB and reduced left ventricular systolic function, and indication for CRT or ventricular pacing. Methods: LBBAP was attempted in patients with left ventricular ejection fraction (LVEF) <50%, RBBB, HF, and indications for CRT or ventricular pacing. Procedural, pacing, and electrocardiographic parameters; clinical response (no HF hospitalization and improvement in NYHA class); and echocardiographic response (≥5% increase in ejection fraction) to LBBAP were assessed. Results: LBBAP was attempted in 121 patients and successful in 107 (88%). Patient characteristics included age 74 ± 12 years, female 25%, ischemic cardiomyopathy 49%, and ejection fraction 35% ± 9%. QRS axis at baseline was normal in 24%, left axis 63%, right axis 13%. LBBAP threshold and R-wave amplitudes were 0.8 ± 0.3 V @ 0.5 ms and 10 ± 9 mV at implant and remained stable during mean follow-up of 13 ± 8 months. LBBAP resulted in narrowing of QRS duration (156 ± 20 ms to 150 ± 24 ms (P = .01) with R-wave peak times in V6 of 85 ± 16 ms. LVEF improved from 35% ± 9% to 43% ± 12% (P < .01). Clinical and echocardiographic response was observed in 60% and 61% of patients, respectively. Female sex and reduction in QRS duration with LBBAP were predictive of echocardiographic response and super-response. Conclusion: LBBAP is a feasible alternative to deliver CRT or physiologic ventricular pacing in patients with RBBB, HF, and LV dysfunction.

13.
J Arrhythm ; 37(6): 1497-1505, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34887954

RESUMO

BACKGROUND: Catheter ablation of premature ventricular complexes from aortic sinus cusps (ASC-PVC) is a complex procedure that conventionally requires coronary catheterization (CC) to localize coronary artery ostium (CAO). Little published information is available on the mapping and ablation with zero-fluoroscopy (ZF) of ASC-PVC. The aim of the study was to determine the efficacy and safety of ASC-PVC ablation with a ZF approach guided by 3D intracardiac echocardiography integration in the electroanatomical mapping system (ICE 3D-EAM). METHODS: This observational study included one patient cohort treated conventionally and another treated with ICE 3D-EAM-guided ZF ablation. Clinical, efficacy, and safety outcomes were evaluated acutely and at 3 months follow-up. RESULTS: The study included 21 patients with ASC-PVC: 10 in the ZF group (age 49 ± 16 years, 60% males) and 11 in the control group (age 47 ± 15 years, 27% males). Fluoroscopy was not required for any patient in the ZF group. Acute success was obtained in 80% of the ZF group vs 55% of the control group (P = .36). The recurrence rate was 30% in the ZF group vs 27% in the control group (P = 1). One nonsevere complication was observed in the ZF group (P = .48). CONCLUSIONS: ZF catheter ablation of ASC-PVC guided by ICE 3D-EAM is feasible, effective, and safe.

14.
CJC Open ; 2(6): 705-707, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33305233

RESUMO

An 81-year-old man with second-degree atrioventricular block was admitted to our centre for pacemaker implantation. Electroanatomic mapping and intracardiac echocardiography-guided left-bundle branch area pacing was performed, entirely without fluoroscopy. It is the first report to describe intracardiac echocardiography for guiding sheath movements into the heart. In conclusion, the combined use of intracardiac echocardiography and intracardiac navigation system allows us to perform left-bundle branch pacing without fluoroscopy.


Un homme de 81 ans présentant un bloc auriculoventriculaire du second degré a été hospitalisé dans notre centre en vue de l'implantation d'un stimulateur cardiaque. On a effectué une cartographie électro-anatomique et une stimulation de la branche gauche guidée par échocardiographie intracardiaque, entièrement sans fluoroscopie. C'est la première fois qu'on décrit l'utilisation de l'échocardiographie intracardiaque pour guider les mouvements de la gaine dans le cœur. En conclusion, l'utilisation conjointe de l'échocardiographie intracardiaque et d'un système de navigation intracardiaque nous permet d'effectuer une stimulation de la branche gauche sans fluoroscopie.

15.
Rev Esp Cardiol (Engl Ed) ; 73(6): 471-478, 2020 Jun.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-31952933

RESUMO

INTRODUCTION AND OBJECTIVES: Several studies have linked the presence of atrial fibrillation (AF) with reduced estimated glomerular filtration rate (eGFR). Our objective was to compare changes in eGFR in patients with AF after pulmonary vein (PV) ablation depending on the success of the technique, as well as to examine the relationship between eGFR and several biomarkers. METHODS: Prospective cohort of patients with AF referred to our center for PV ablation with a 1-year follow-up. We estimated eGFR using the Chronic Kidney Disease Epidemiology Collaboration formula at baseline and at 3 and 12 months. Biomarkers (B-type natriuretic peptide, corin, and galectin-3) were measured before ablation and at 12 months. RESULTS: We studied 124 patients (age 55±10 years, 69.4% men). Seventy-five had paroxysmal AF (60.5%). The mean baseline eGFR was 90.8 [77.8-100.0] mL/min/1.73 m2. The eGFR increased at the end of follow-up, with a statistically significant difference between patients with recurrence at 12 months and those without (-1.1 [-6.0 to 8.8] mL/min/1.73 m2 vs 7.1 [-0.6 to 14.2] mL/min/1.73 m2, P=.017). The improvement in eGFR at 12 months was inversely proportional to baseline eGFR. B-type natriuretic peptide and corin levels improved at 12 months, while galectin-3 levels worsened, which was unrelated to eGFR. CONCLUSIONS: In patients with AF treated with PV ablation, an overall improvement in eGFR was observed, which was more marked in the subgroup without recurrences, although without significant differences on multivariate analysis.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Idoso , Fibrilação Atrial/cirurgia , Feminino , Humanos , Rim/cirurgia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
18.
Rev. colomb. cardiol ; 29(3): 286-294, mayo-jun. 2022. tab, graf
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1407980

RESUMO

Resumen Introducción: Estudios previos han relacionado la presencia de fibrilación auricular (FA) con una tasa de filtrado glomerular estimada (TFGe) reducida. Objetivo: comparar la evolución de la TFGe en pacientes con FA persistente tras cardioversión eléctrica (CVE) programada en función de la existencia o no de recurrencias, así como la evolución de varios biomarcadores. Materiales y métodos: Cohorte prospectiva de pacientes con FA persistente remitidos a nuestro centro para CVE programada con seguimiento de un año. La TFGe se obtuvo mediante la fórmula CKD-EPI en el momento basal y a los 3 y 12 meses. Se midieron biomarcadores antes de la CVE y a los 12 meses. Resultados: Se incluyeron 92 pacientes con FA persistente, edad media de 64 ± 11 años. Al año de seguimiento y en el total de pacientes, la TFGe se redujo de 86,5 [74,6-97,6 a 84,5 [71,7-95,1 ml/min/1,73 m2 (p = 0,002) y la creatinina aumentó de 0,80 [0,72-0,94] mg/dl a 0,83 [0,74-0,97] mg/dl (p = 0,005). La TFGe se redujo al final del seguimiento, sin diferencia estadísticamente significativa entre los pacientes que presentaron recurrencia a los 12 meses y los que no. Las cifras de BNP y corina mejoraron a los 12 meses, mientras que las de galectina-3 no cambiaron, sin relación con la TFGe. Conclusiones: En los pacientes con FA persistente tratados con CVE programada se observó un empeoramiento de la TFGe al año de seguimiento. Los niveles de BNP y corina mejoraron al año de seguimiento. No hubo diferencias en los niveles de galectina-3.


Abstract Introduction: Previous studies have linked the presence of atrial fibrillation (AF) with a reduced estimated glomerular filtration rate (eGFR). Objective: to compare the evolution of eGFR in patients with persistent AF after elective electrical cardioversion (ECV) based on the existence or not of recurrences, as well as the evolution of various biomarkers. Materials and methods: Prospective cohort of patients with persistent AF referred to our center for elective EVC with a 1-year follow-up. The eGFR was obtained using the CKD-EPI formula at baseline and at 3 and 12 months. Biomarkers were measured before ECV and at 12 months. Results: 92 patients with persistent AF were included, mean age 64 ± 11 years. At one year of follow-up and in all patients, the eGFR decreased from 86.5 [74.6-97.6 to 84.5 [71.7-95.1 ml/min/1.73 m2 (p = 0.002) and creatinine increased from 0.80 [0.72-0.94] mg/dl to 0.83 [0.74-0.97] mg/dl (p = 0.005). The eGFR was reduced at the end of the follow-up, with no statistically significant difference between the patients who had recurrence at 12 months and those who did not. BNP and corin levels improved at 12 months, while galectin-3 did not change, unrelated to eGFR. Conclusions: In patients with persistent AF treated with elective ECV, a worsening of eGFR was observed at one year of follow-up. BNP and corin levels improve at one year of follow-up, there were no differences in galectin-3 levels.