Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 53
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Vasc Interv Radiol ; 27(7): 1027-33, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27241396

RESUMO

PURPOSE: To report results of a 16-F sheath/endobronchial forceps combination in retrieval of "closed cell" inferior vena cava (IVC) filter designs with prolonged dwell times of ≥ 60 days. MATERIALS AND METHODS: Forceps retrieval of selected IVC filters using a 16-F 45-cm sheath was performed in 35 patients (25 women and 10 men). Patients presented with filters that were no longer needed without (n = 10) or with (n = 21) prior failed retrieval, caval thrombosis before lysis (n = 3), and back pain (n = 1). Filter designs included 19 Günther Tulip (54%), 10 Option (29%), and six OptEase (17%). Mean dwell time was 977 days. Imaging characteristics, technical success, fluoroscopy time, and complications were recorded. RESULTS: Filters included 20 tip-embedded, 6 tip-adherent, 4 fractured, and 6 containing thrombus. All were strut and wall-embedded. Initial snare failures occurred in 8 filters because of hook straightening (n = 4), adherent material (n = 2), snare breakage (n = 1), and filter tilt (n = 1). The 16-F sheath/forceps combination was 100% successful in removing filters. In 1 patient, 2 extravascular fragments could not be retrieved. Median fluoroscopy time, excluding 3 extended lysis procedures, was 8 minutes. Minor caval abnormalities, including caval spasm and caval defects, were noted in 17 patients, and filter fracture occurred in 2 patients. No major complications occurred. CONCLUSIONS: A high rate of retrieval for closed cell long-dwelling strut and wall-embedded filters may be achieved using a 16-F sheath/endobronchial forceps combination.


Assuntos
Remoção de Dispositivo/instrumentação , Implantação de Prótese/instrumentação , Instrumentos Cirúrgicos , Filtros de Veia Cava , Veia Cava Inferior , Adulto , Idoso , Idoso de 80 Anos ou mais , Remoção de Dispositivo/efeitos adversos , Remoção de Dispositivo/métodos , Desenho de Equipamento , Feminino , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Philadelphia , Flebografia , Desenho de Prótese , Radiografia Intervencionista/métodos , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento , Veia Cava Inferior/diagnóstico por imagem , Adulto Jovem
2.
Radiology ; 275(3): 900-7, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25581368

RESUMO

PURPOSE: To evaluate the use of endobronchial forceps to retrieve tip-embedded inferior vena cava (IVC) filters. MATERIALS AND METHODS: This institutional review board-approved, HIPAA-compliant retrospective study included 114 patients who presented with tip-embedded IVC filters for removal from January 2005 to April 2014. The included patients consisted of 77 women and 37 men with a mean age of 43 years (range, 18-79 years). Filters were identified as tip embedded by using rotational venography. Rigid bronchoscopy forceps were used to dissect the tip or hook of the filter from the wall of the IVC. The filter was then removed through the sheath by using the endobronchial forceps. Statistical analysis entailed calculating percentages, ranges, and means. RESULTS: The endobronchial forceps technique was used to successfully retrieve 109 of 114 (96%) tip-embedded IVC filters on an intention-to-treat basis. Five failures occurred in four patients in whom the technique was attempted but failed and one patient in whom retrieval was not attempted. Filters were in place for a mean of 465 days (range, 31-2976 days). The filters in this study included 10 Recovery, 33 G2, eight G2X, 11 Eclipse, one OptEase, six Option, 13 Günther Tulip, one ALN, and 31 Celect filters. Three minor complications and one major complication occurred, with no permanent sequelae. CONCLUSION: The endobronchial forceps technique can be safely used to remove tip-embedded IVC filters.


Assuntos
Remoção de Dispositivo/instrumentação , Remoção de Dispositivo/métodos , Falha de Prótese , Filtros de Veia Cava , Adolescente , Adulto , Idoso , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Instrumentos Cirúrgicos , Adulto Jovem
3.
J Vasc Interv Radiol ; 26(12): 1806-13.e1, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26481824

RESUMO

PURPOSE: To report outcomes of bronchial artery embolization (BAE) for hemoptysis, including recurrent bleeding, survival, and longitudinal pulmonary function. MATERIALS AND METHODS: A prospective database identified 69 patients who underwent 97 BAE procedures (n = 1-7 per patient) at a tertiary academic medical center over a period of 11 years. Technical and clinical success were determined. Recurrent bleeding and survival were compared by etiology of lung disease. Rates of change in pulmonary function (forced expiratory volume in 1 s [FEV1] and forced vital capacity [FVC]) were measured and compared before and after index BAE by linear regression in 17 patients. RESULTS: The technical success rate of BAE was 90%. Clinical success rates at 24 hours and 30 days were 82% and 68%, respectively. Thirty percent of patients had recurrent bleeding that required bronchoscopy (7%) or additional embolization (23%). Median time to recurrent bleeding was 29 days among the 13 patients with sarcoidosis, compared with 293 days among patients without sarcoidosis (P = .0013). The hazard ratio for death in patients with sarcoidosis compared with those without sarcoidosis was 4 (95% confidence interval, 2.6-14.6). Analyzing all instances of pulmonary function tests, slopes of decline in FEV1 and FVC were significantly different (FEV1, P = .0048; FVC, P < .0001) before and after index BAE, with an improvement after BAE (FEV1, 0.8%/y; FVC, 1%/y) and a decrease before BAE (FEV1, -1.6%/y; FVC, -1.4%/y). CONCLUSIONS: BAE is an effective therapy for hemoptysis, but patients with sarcoidosis are at significant risk of recurrent bleeding and death compared with patients with other lung diseases. BAE does not accelerate deterioration in lung function.


Assuntos
Artérias Brônquicas , Embolização Terapêutica/mortalidade , Hemoptise/mortalidade , Hemoptise/terapia , Hemorragia/mortalidade , Testes de Função Respiratória/estatística & dados numéricos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Causalidade , Comorbidade , Feminino , Hemoptise/diagnóstico , Hemorragia/prevenção & controle , Humanos , Masculino , Pessoa de Meia-Idade , Prevalência , Recidiva , Estudos Retrospectivos , Fatores de Risco , Taxa de Sobrevida , Resultado do Tratamento , Estados Unidos/epidemiologia , Adulto Jovem
4.
J Vasc Interv Radiol ; 26(7): 1032-9, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25890686

RESUMO

PURPOSE: To evaluate long-term outcomes of a structured protocol for percutaneous treatment of benign biliary stricture. MATERIALS AND METHODS: Seventy-one patients (37 men, 34 women; mean age, 54 y; age range, 23-84 y) entered the protocol, which consisted of staged upsizing of internal/external biliary catheters, balloon dilation (nominally 8 mm), and prolonged stent treatment (6 mo) at maximal catheter size (nominally 18 F). It concluded with a capping trial and catheter removal if the stricture remained patent. Fifty-three patients completed the protocol and 18 did not (6 died, 6 underwent alternative treatment, 4 were lost to follow-up, and 2 underwent repeat transplantation). Stricture features, treatment parameters, complications, and outcomes were reviewed, and Kaplan-Meier analysis was conducted. RESULTS: Strictures were anastomotic in 45 patients (64%), intrahepatic in 14 (20%), extrahepatic in 7 (10%), and multiple (intra- and extrahepatic) in 5 (7%). A right-sided approach was used in 47 patients (66%) patients, a left-sided approach in 18 (25%), and a bilateral approach in 6 (9%). Forty-six patients who entered the protocol (65%) and 46 patients who completed the protocol (87%) showed stricture patency. Four of 7 patients in whom a capping trial failed underwent surgical revision, 2 required chronic biliary drainage, and 1 received a metal stent. Follow-up (range, 0-12 y; mean, 4.7 y) was obtained for 42 of 53 patients who completed the protocol (79%). Kaplan-Meier analysis showed stricture patency probabilities of 84% at 1 year after treatment, 78% at 2 years, 74% at 5 years, and 67% at 10 years. CONCLUSIONS: Use of a structured protocol for the percutaneous treatment of benign biliary strictures yields durable long-term results, suggesting that percutaneous treatment is an effective therapy.


Assuntos
Cateterismo , Colestase/terapia , Procedimentos Cirúrgicos do Sistema Digestório/efeitos adversos , Drenagem , Doença Iatrogênica , Transplante de Fígado/efeitos adversos , Adulto , Idoso , Idoso de 80 Anos ou mais , Cateterismo/efeitos adversos , Cateterismo/instrumentação , Catéteres , Distribuição de Qui-Quadrado , Colestase/diagnóstico , Colestase/etiologia , Dilatação , Drenagem/efeitos adversos , Drenagem/instrumentação , Drenagem/métodos , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Avaliação de Programas e Projetos de Saúde , Modelos de Riscos Proporcionais , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Stents , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
5.
J Vasc Interv Radiol ; 26(7): 984-91, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25890685

RESUMO

PURPOSE: To quantify the effect of central venous percutaneous transluminal angioplasty (PTA) on blood flow within hemodialysis access circuits in patients with symptomatic central venous stenosis (CVS). MATERIALS AND METHODS: This prospective study enrolled 30 adults with symptoms attributable to CVS ipsilateral to their access. Five subjects were deregistered because of a lack of CVS (n = 1), untreatable lesion (n = 1), or improper flow measurement timing (n = 3); 25 completed the study (15 men and 10 women; mean age, 62 y; age range, 33-87 y). There were 7 fistulae, 15 grafts, and 3 hybrid access circuits. Mean access age was 675 days (range, 16-3,039 d). Mean CVS symptom duration was 37 days (range, 3-120 d). Peripheral stenoses, if present, were treated first. Intraaccess flow was measured immediately before and immediately after CVS treatment (PTA, stent). RESULTS: Eleven patients had only CVS, whereas 14 had at least 1 peripheral lesion in addition to CVS. All stenoses underwent PTA. Mean flow rates were 1,424 mL/min (range, 565-2,765 mL/min) before PTA and 1,535 mL/min (range, 598-2,545 mL/min) afterward, yielding a mean increase of 111 mL/min ± 456 or 15% ± 34 (range, -70% to +100%; 95% confidence interval, 1%-29%). Flow was decreased in 9 patients (36%). CVS symptoms were reduced in 24 patients (96%) and recurred in 14 (58%) within a mean of 110 days (range, 7-459 d) after initial PTA. Mean follow-up was 371 days (range, 17-592 d). CONCLUSIONS: CVS symptoms were observed to occur over a wide range of blood flow rates. On average, central venous PTA only mildly increased flow yet reduced symptoms regardless of flow change.


Assuntos
Angioplastia com Balão , Derivação Arteriovenosa Cirúrgica , Implante de Prótese Vascular , Cateterismo Venoso Central/efeitos adversos , Diálise Renal , Doenças Vasculares/terapia , Veias/fisiopatologia , Adulto , Idoso , Derivação Arteriovenosa Cirúrgica/efeitos adversos , Velocidade do Fluxo Sanguíneo , Implante de Prótese Vascular/efeitos adversos , Constrição Patológica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fluxo Sanguíneo Regional , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Doenças Vasculares/diagnóstico , Doenças Vasculares/etiologia , Grau de Desobstrução Vascular
6.
J Vasc Interv Radiol ; 26(10): 1501-8, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26239895

RESUMO

PURPOSE: To report preliminary clinical experience with a new symmetric-tip dialysis catheter compared with a conventional split-tip catheter. MATERIALS AND METHODS: Over a 5-month period, patients requiring a tunneled catheter for hemodialysis or undergoing exchange of a dysfunctional dialysis catheter at a tertiary academic medical center were retrospectively analyzed. Patients underwent placement of a VectorFlow or Ash Split Cath catheter at the discretion of the inserting interventional radiologist. Patient demographics, catheter patency, mean blood flow rate, and arterial and venous pressures were compared according to catheter type. Catheter failure was analyzed based on clinical and anatomic variables by using a multivariate Cox proportional-hazards model. RESULTS: A total of 33 VectorFlow and 46 Ash Split Cath catheters were placed. Patients in the VectorFlow group had significantly higher body mass index (P = .013) and Charlson Comorbidity Index (P = .049), as well as more non-internal jugular vein placements. At 120 days, 89% of VectorFlow catheters remained functional, compared with 45% of Ash Split Cath catheters (P = .046). The VectorFlow catheter was associated with 16% lower arterial pressures during dialysis (P = .009); mean blood flow rate was equivalent. On multivariate analysis, the risk of catheter failure was 13.3 times higher in the Ash Split Cath group compared with the VectorFlow group (P = .004). Left-sided catheters were also predictive of catheter failure (relative risk = 5.5; P = .02). CONCLUSIONS: The VectorFlow catheter was associated with a significant increase in intervention-free catheter patency compared with the Ash Split Cath catheter, with equivalent flow at lower arterial pressures during dialysis.


Assuntos
Cateterismo Venoso Central/instrumentação , Cateteres de Demora , Cateteres Venosos Centrais , Veias Jugulares/fisiopatologia , Diálise Renal/instrumentação , Velocidade do Fluxo Sanguíneo , Cateterismo Venoso Central/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Diálise Renal/métodos , Resultado do Tratamento
7.
J Vasc Interv Radiol ; 26(9): 1257-65; quiz 1265, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25990133

RESUMO

PURPOSE: To evaluate long-term patency and symptomatic recurrence rates following transjugular intrahepatic portosystemic shunt (TIPS) creation with expanded polytetrafluoroethylene (ePTFE)-covered stent grafts and to determine the necessity of extended clinical follow-up beyond 2 years after TIPS creation. MATERIALS AND METHODS: A retrospective review including 262 TIPSs created with ePTFE-covered stent grafts between July 2002 and October 2012 was performed. Primary, primary assisted, and secondary patency rates were calculated. Assessment of clinical data included technical, hemodynamic, and clinical success rates, as well as mortality after TIPS creation. RESULTS: Primary patency rates at 2, 4, and 6 years were 74%, 62%, and 50%, respectively. Primary assisted patency rates at 2, 4, and 6 years were 93%, 85%, and 78%, respectively. Secondary patency rates at 2, 4, and 6 years were 99%, 91%, and 84%, respectively. Technical and hemodynamic success rates were 99% and 93%, respectively. Clinical success rates for refractory ascites were 66% (complete response) and 90% (partial response); clinical success rate for bleeding/varices was 90%. Mortality rates at 2, 4, and 6 years after TIPS creation were 27%, 38%, and 46%, respectively. At the median wait time until transplantation, patients had an 84% chance of being alive. TIPS dysfunction developed in 21% of patients; 30% of revisions occurred later than 2 years during follow-up. CONCLUSIONS: Beyond 2 years after TIPS creation, patency rates gradually decrease, mortality rates continue to increase, and the chance of recurrent ascites or bleeding remains present. Together, these findings suggest that continued clinical follow-up beyond 2 years is necessary in patients with a TIPS created with an ePTFE-covered stent graft.


Assuntos
Rejeição de Enxerto/mortalidade , Sobrevivência de Enxerto , Hipertensão Portal/mortalidade , Hipertensão Portal/terapia , Politetrafluoretileno/química , Derivação Portossistêmica Transjugular Intra-Hepática/mortalidade , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Materiais Revestidos Biocompatíveis/química , Intervalo Livre de Doença , Feminino , Rejeição de Enxerto/diagnóstico , Humanos , Hipertensão Portal/diagnóstico , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Derivação Portossistêmica Transjugular Intra-Hepática/estatística & dados numéricos , Desenho de Prótese , Recidiva , Reoperação/estatística & dados numéricos , Estudos Retrospectivos , Fatores de Risco , Taxa de Sobrevida , Resultado do Tratamento , Estados Unidos , Grau de Desobstrução Vascular , Adulto Jovem
8.
J Vasc Interv Radiol ; 25(4): 542-7, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24508347

RESUMO

PURPOSE: To determine whether angioplasty of inflow stenosis in malfunctioning but patent autogenous hemodialysis fistulae has an impact on postintervention primary patency in patients without a clinical indicator of inflow-related access malfunction. MATERIALS AND METHODS: Medical records for 76 procedures in 62 patients with inflow stenoses undergoing fistulography in nonthrombosed mature autogenous fistulae without an inflow-related indication of access malfunction over a 5-year period were reviewed retrospectively. Control and treatment arms were defined as patients with untreated (26 procedures in 23 patients) and treated (50 procedures in 39 patients) inflow stenoses, respectively. All patients in both arms of the study had concurrent intrafistula and/or venous outflow stenosis, which were treated successfully with angioplasty. The clinical endpoint was defined as return for a failing or thrombosed access (ie, primary patency). A two-tailed unpaired Student t test was performed to compare primary patency and percent inflow stenosis in treatment (angioplasty) and control (untreated inflow stenoses) groups, with significance defined at P < .05. Kaplan-Meier analysis was performed. RESULTS: There was no significant difference in percent inflow stenosis between control and treatment arms (P = .95). There was no significant difference in access patency between the two groups (139 and 124 d for control and treated groups, respectively; P = .95). No procedural complications occurred in either arm of the study. CONCLUSIONS: Angioplasty of inflow stenosis in failing autogenous fistulae without an appropriate clinical indicator of an inflow pathologic process does not improve postintervention primary patency.


Assuntos
Angioplastia , Derivação Arteriovenosa Cirúrgica/efeitos adversos , Oclusão de Enxerto Vascular/terapia , Diálise Renal , Coxa da Perna/irrigação sanguínea , Extremidade Superior/irrigação sanguínea , Idoso , Idoso de 80 Anos ou mais , Feminino , Oclusão de Enxerto Vascular/diagnóstico , Oclusão de Enxerto Vascular/etiologia , Oclusão de Enxerto Vascular/fisiopatologia , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Fluxo Sanguíneo Regional , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
9.
J Vasc Interv Radiol ; 25(6): 823-32, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24788209

RESUMO

PURPOSE: To assess the efficacy of two embolic agents in the treatment of symptomatic uterine leiomyomas. MATERIALS AND METHODS: A randomized, prospective, single-center study enrolled 60 women with symptomatic uterine leiomyomas. Uterine artery embolization (UAE) with spherical polyvinyl alcohol (SPVA) microspheres (n = 30; 700-900 µm and 900-1,200 µm; near-stasis or stasis endpoint) and tris-acryl gelatin (TAG) microspheres (n = 30; 500-700 µm; "pruned-tree" endpoint) was performed. Infarction rates were calculated for the dominant tumor and for small (< 2 cm) and large (> 2 cm) nondominant tumors. The primary endpoint was tumor infarction at 24 hours measured by contrast-enhanced magnetic resonance imaging assessed by a blinded reviewer. RESULTS: Baseline characteristics were similar between groups. The primary endpoint was similar in both treatments (≥ 91% dominant tumor infarction; SPVA. 86.2%; TAG, 93.3%, P = .35). Complete infarction (100%) was also similar between arms at 24 hours and 3 months. Symptom severity was reduced and quality of life improved equally at 3 and 12 months in each treatment group. Complications were minor in both groups. CONCLUSIONS: Uterine leiomyoma infarction at 24 hours and 3 months after treatment with SPVA or TAG microspheres was comparable when using near-stasis as a procedural endpoint with SPVA microspheres. Symptom relief was maintained for as long as 12 months for both embolic agents.


Assuntos
Resinas Acrílicas/administração & dosagem , Gelatina/administração & dosagem , Leiomioma/terapia , Álcool de Polivinil/administração & dosagem , Embolização da Artéria Uterina/métodos , Neoplasias Uterinas/terapia , Resinas Acrílicas/efeitos adversos , Adulto , Meios de Contraste , Feminino , Gelatina/efeitos adversos , Humanos , Infarto/patologia , Leiomioma/irrigação sanguínea , Leiomioma/diagnóstico , Imageamento por Ressonância Magnética , Microesferas , Pessoa de Meia-Idade , Philadelphia , Álcool de Polivinil/efeitos adversos , Estudos Prospectivos , Qualidade de Vida , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento , Embolização da Artéria Uterina/efeitos adversos , Neoplasias Uterinas/irrigação sanguínea , Neoplasias Uterinas/diagnóstico
10.
Cardiovasc Intervent Radiol ; 47(1): 60-68, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38057498

RESUMO

PURPOSE: Capecitabine-Temozolomide (CapTem) is an oral chemotherapy regimen for NETs. Both drugs are radiosensitizers. Integrating CapTem and Y90 transarterial radioembolization (TARE) in patients with grade 2 neuroendocrine tumor (NET) liver metastases achieved an encouraging objective response rate (ORR) and progression-free survival (PFS) in a feasibility study. This study expands that report to a larger cohort with longer follow-up. METHODS: Therapy consisted of monthly cycles of capecitabine 600 mg/m2 twice daily for 14 days and temozolomide 150-200 mg/m2 on day 10-14. Simulation angiography was performed during the initial cycle. The dominant lobe was treated with 90Y-resin microspheres using BSA dosimetry on day 7 of the second cycle of CapTem. Patients with bilobar disease had the other lobe treated on day 7 of the third or fourth cycle. CapTem was continued until progression or intolerance. Clinical and laboratory assessment was done monthly and imaging every 3 months. RESULTS: 35/37 patients completed the prescribed regimen. Primary sites of disease were pancreas (16), lung (10), gut (7) and unknown (4). Mean duration of CapTem was 12 months (range, 4-32 months). ORR in the liver was 72% with a disease control rate of 100%. Median PFS was 36 months (95% CI, 25-45 months). Median overall survival was 41 months (95% CI, 24-87 months) from initiation of CapTemY90 therapy and 130 months (95% CI, 56-172 months) from initial diagnosis. CONCLUSION: Chemoradiation with CapTem and TARE provided durable control of G2 NET liver metastases for substantially longer than expectations for embolotherapy or chemotherapy alone.


Assuntos
Neoplasias Hepáticas , Tumores Neuroendócrinos , Humanos , Capecitabina/uso terapêutico , Temozolomida/uso terapêutico , Estudos Retrospectivos , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Tumores Neuroendócrinos/patologia , Neoplasias Hepáticas/terapia , Neoplasias Hepáticas/tratamento farmacológico
11.
J Vasc Interv Radiol ; 24(5): 722-5, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23541281

RESUMO

PURPOSE: To complement prior studies that have shown that arteriovenous fistula (AVF) thrombectomies require more time and equipment than arteriovenous graft (AVG) thrombectomies by measuring work via established instruments to determine whether there is also a difference in maintenance percutaneous transluminal angioplasty (PTA) of nonthrombosed AVFs versus AVGs. MATERIALS AND METHODS: PTA procedures performed on a consecutive cohort of 42 patients with AVFs and 27 patients with AVGs were prospectively compared. To quantify resource utilization, procedure time and disposable equipment were measured. Established instruments developed by the American Medical Association for Current Procedural Terminology code valuation were used to measure subjective "physician work," including mental effort and judgment, technical skill, physical effort, and psychological stress. These items were scored by 1 of 12 attending interventional radiology physicians performing the procedure. RESULTS: Mean PTA procedure time was 74 minutes (range, 18-183 minutes) for AVFs and 71 minutes (range, 28-204 minutes) for AVGs; hemostasis time was 12 minutes for AVFs and 11 minutes for AVGs. There was no significant difference in equipment use between groups. "Physician work" for AVFs scored significantly higher in four categories (P≤ .05). CONCLUSIONS: Using established subjective instruments, maintenance PTA of AVFs was scored as more cognitively, physically, and psychologically demanding than maintenance PTA of AVGs. However, there was no significant difference in resource utilization between maintenance PTA of AVFs versus AVGs, as has been previously shown with thrombectomy of thrombosed AVFs and AVGs.


Assuntos
Angioplastia/estatística & dados numéricos , Derivação Arteriovenosa Cirúrgica/estatística & dados numéricos , Prótese Vascular/estatística & dados numéricos , Duração da Cirurgia , Médicos/estatística & dados numéricos , Diálise Renal/estatística & dados numéricos , Carga de Trabalho/estatística & dados numéricos , Humanos , Philadelphia/epidemiologia , Trombose/epidemiologia , Trombose/cirurgia
12.
J Vasc Interv Radiol ; 24(3): 347-50, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23433410

RESUMO

PURPOSE: To compare the amount of sedation medication administered during radiofrequency (RF) ablation versus cryoablation of small renal masses. MATERIALS AND METHODS: Records were retrospectively reviewed in patients who underwent percutaneous computed tomography-guided RF ablation and cryoablation of small renal masses from January 2002 to June 2011 for patient and tumor characteristics, amount of medications used for moderate sedation, and complications. Sedation was performed by giving patients titrated doses of midazolam and fentanyl. Additional medications were given if the desired level of sedation was not achieved. RESULTS: There were 116 patients who underwent 136 ablation procedures; 71 patients underwent RF ablation, and 65 patients underwent cryoablation. RF ablation was associated with a significantly higher mean dose of fentanyl (mean dose for RF ablation, 236.43 µg; mean dose for cryoablation, 172.27 µg; P<.001). RF ablation was also associated with a higher mean dose of midazolam (mean dose for RF ablation, 4.5 mg; mean dose for cryoablation, 3.27 mg; P<.001). In the RF ablation group, two patients required additional sedation with droperidol. As a result of oversedation, two patients in the RF ablation cohort required sedation reversal with naloxone and flumazenil. None of the patients who underwent cryoablation required sedation reversal. No other sedation-related complications occurred. CONCLUSIONS: Cryoablation of small renal masses was performed with less sedation medication than RF ablation. This finding suggests renal cryoablation is less painful than RF ablation; however, prospective studies with validated pain scales are needed to confirm these results.


Assuntos
Ablação por Cateter , Criocirurgia , Hipnóticos e Sedativos/administração & dosagem , Neoplasias Renais/cirurgia , Dor Pós-Operatória/prevenção & controle , Cirurgia Assistida por Computador , Tomografia Computadorizada por Raios X , Adulto , Idoso , Idoso de 80 Anos ou mais , Ablação por Cateter/efeitos adversos , Criocirurgia/efeitos adversos , Droperidol/administração & dosagem , Feminino , Fentanila/administração & dosagem , Humanos , Hipnóticos e Sedativos/efeitos adversos , Neoplasias Renais/diagnóstico por imagem , Neoplasias Renais/patologia , Masculino , Midazolam/administração & dosagem , Pessoa de Meia-Idade , Medição da Dor , Dor Pós-Operatória/diagnóstico , Dor Pós-Operatória/etiologia , Estudos Retrospectivos , Cirurgia Assistida por Computador/efeitos adversos , Resultado do Tratamento , Carga Tumoral
13.
J Vasc Interv Radiol ; 24(5): 717-21, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23541282

RESUMO

PURPOSE: To investigate retrospectively the use of catheter-based intraaccess blood flow measurements as an adjunct to physical examination and fistulography in hemodialysis access interventions. MATERIALS AND METHODS: Among 1,540 dialysis interventions performed at a single institution in a 2.5-year period, 104 qualifying catheter-based flow measurements were made in 70 mature native fistula interventions in 55 patients and 34 graft interventions in 31 patients. The flow rate threshold prompting intervention was generally 600 mL/min, but some variation existed depending on the clinical setting. RESULTS: The most common indication for measurement of blood flow was to determine the hemodynamic significance of a fistula inflow stenosis (n = 25), of which only four had subsequent intervention. Other common indications included decision-making resulting in further angioplasty or stent implantation of noninflow lesions (fistulas, n = 10; grafts, n = 23) versus termination of the procedure (n = 23), problem-solving in cases in which there was no visible lesion to explain the clinical indicator of access failure (n = 17), evaluation for high-flow-related cardiac risk in aneurysmal fistulas (n = 13), suboptimal evaluation of the inflow (n = 8), and suboptimal physical examination (n = 6). Overall, flow measurements supported a decision to perform angioplasty (n = 11) or stent placement (n = 3) in 17% of fistula interventions and 35% of graft interventions. CONCLUSIONS: The major benefit of flow measurement was to support a decision to withhold further angioplasty or stent placement.


Assuntos
Derivação Arteriovenosa Cirúrgica/instrumentação , Circulação Renal , Diálise Renal/instrumentação , Diálise Renal/estatística & dados numéricos , Reologia/instrumentação , Reologia/estatística & dados numéricos , Dispositivos de Acesso Vascular/estatística & dados numéricos , Adulto , Idoso , Derivação Arteriovenosa Cirúrgica/métodos , Derivação Arteriovenosa Cirúrgica/estatística & dados numéricos , Velocidade do Fluxo Sanguíneo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pennsylvania/epidemiologia , Diálise Renal/métodos , Estudos Retrospectivos , Resultado do Tratamento
14.
J Vasc Interv Radiol ; 24(12): 1765-72; quiz 1773, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24409470

RESUMO

PURPOSE: To compare postpercutaneous intervention outcomes of autogenous venous-transposition arteriovenous fistulas (AVFs) versus those of autogenous nontransposed AVFs (nAVFs) and prosthetic arteriovenous grafts (AVGs). MATERIALS AND METHODS: A total of 591 hemodialysis accesses (195 transposed AVFs [tAVFs], 205 nAVFs, 191 AVGs) in 522 patients (278 male; mean age, 57 y; range, 15­91 y) underwent percutaneous transluminal angioplasty (PTA) and/or mechanical thrombectomy (ie, declotting). Access characteristics, surgical history, percutaneous interventions, postinterventional primary and secondary access patency, and follow-up data were collected. Cox proportional-hazards regression analyses, Fisher exact tests, and χ2 tests were performed. RESULTS: Mean follow-up period was 32 months. Mean access ages at initial percutaneous intervention were 260 days (tAVF), 206 days (nAVF), and 176 days (AVG; P < .01). One-year postinterventional primary patency (PIPP) rates were 25% (tAVF), 24% (nAVF), and 14% (AVG). One-year postinterventional secondary patency (PISP) rates were 77% (tAVF), 61% (nAVF), and 63% (AVG). Median PIPP durations were 138 days (tAVF), 121 days (nAVF), and 79 days (AVG; P = .0001). Median PISP durations were 1,076 days (tAVF), 783 days (nAVF), and 750 days (AVG; P = .019). Total interventions needed to maintain PISP were 2.4 (tAVF), 1.3 (nAVF), and 3.2 (AVG) per patient-year (P < .001), which included 1.9, 1.2, and 1.4 PTAs (P < .01) and 0.45, 0.15, and 1.8 declotting procedures, respectively (P < .001). CONCLUSIONS: Based on the number of percutaneous interventions needed to maintain PISP, these results confirm the current Dialysis Outcomes Quality Initiative access preference of nAVFs before tAVFs before AVGs. tAVFs offered superior postinterventional outcomes than AVGs. With additional interventions, tAVFs could even outperform nAVFs in terms of PISP.


Assuntos
Angioplastia com Balão , Derivação Arteriovenosa Cirúrgica/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Oclusão de Enxerto Vascular/terapia , Diálise Renal , Trombectomia/métodos , Trombose/terapia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Angioplastia com Balão/efeitos adversos , Distribuição de Qui-Quadrado , Feminino , Oclusão de Enxerto Vascular/diagnóstico , Oclusão de Enxerto Vascular/etiologia , Oclusão de Enxerto Vascular/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Fatores de Risco , Trombectomia/efeitos adversos , Trombose/diagnóstico , Trombose/etiologia , Trombose/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular , Adulto Jovem
15.
J Vasc Interv Radiol ; 23(1): 41-5, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22019179

RESUMO

PURPOSE: To examine the effect of percutaneous thermal ablation of renal masses on renal function among patients with baseline chronic kidney disease (CKD). MATERIALS AND METHODS: Patients with baseline CKD (initial glomerular filtration rate [GFR] < 60 mL/min/1.73 m(2)) who underwent percutaneous cryoablation or radiofrequency (RF) ablation of renal masses were reviewed. RESULTS: A total of 48 patients with a GRF of 60 mL/min/1.73 m(2) or lower were treated with renal cryoablation or RF ablation and had follow-up GFR measurement 1 month afterward. Mean patient age was 73 years (range, 47-89 y). Cryoablation was performed in 22 patients and RF ablation was performed in 26. Mean tumor diameter was 3.4 cm (range, 0.9-10.2 cm). Mean overall GFRs were 39.8 mL/min/1.73 m(2) at baseline and 39.7 mL/min/1.73 m(2) at 1 month after ablation (P = .85). A total of 38 patients had 1-year follow-up GFR measurement (cryoablation, n = 18; RF ablation, n = 20), and their mean GFR was 40.9 mL/min/1.73 m(2) ± 11.4 (SD), compared with a preablation GFR of 41.2 mL/min/1.73 m(2)(P = .79). In the cryoablation group, mean GFRs at 1 month and 1 year were 41.4 mL/min/1.73 m(2) and 44.4 mL/min/1.73 m(2), compared with respective baseline GFRs of 41.1 mL/min/1.73 m(2) and 42.1 mL/min/1.73 m(2) (P = .75 and P = .19, respectively). In the RF ablation group, mean GFRs at 1 month and 1 year were 38.2 mL/min/1.73 m(2) and 37.8 mL/min/1.73 m(2), compared with respective baseline GFRs of 38.7 mL/min/1.73 m(2) and 40.4 mL/min/1.73 m(2) (P = .58 and P = .09, respectively). CONCLUSIONS: Independent of ablation modality, percutaneous renal mass ablation does not appear to affect renal function among patients with CKD.


Assuntos
Carcinoma de Células Renais/cirurgia , Ablação por Cateter/métodos , Criocirurgia/métodos , Falência Renal Crônica/complicações , Neoplasias Renais/cirurgia , Idoso , Idoso de 80 Anos ou mais , Carcinoma de Células Renais/diagnóstico por imagem , Carcinoma de Células Renais/patologia , Feminino , Taxa de Filtração Glomerular , Humanos , Neoplasias Renais/diagnóstico por imagem , Neoplasias Renais/patologia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Resultado do Tratamento
16.
J Vasc Interv Radiol ; 22(5): 638-41, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21514517

RESUMO

PURPOSE: To examine the overall durability and breakage rates of dual-lumen silicone catheters in comparison with power-injectable dual-lumen polyurethane catheters. MATERIALS AND METHODS: Patients who received a 10-F dual-lumen silicone catheter or 9.5-F dual-lumen polyurethane catheter between January 2002 and July 2009 were identified through a quality assurance database. Medical records were reviewed retrospectively. A total of 117 silicone and 94 polyurethane catheters were identified in 192 patients. Reasons for catheter placement and removal were recorded, as were cases of breakage and repairs. Catheter durability was compared; survival analysis was also performed. RESULTS: Breakage occurred in nine of 117 silicone catheters (8%) and none of 94 polyurethane catheters (P = .005). Most catheters were placed for malignancy (162 of 211; 77%); nonmalignant indications such as total parenteral nutrition accounted for 49 out of 211 catheters (23%). The mean silicone catheter dwell time was 99 days (11,612 total catheter-days), and the mean polyurethane catheter dwell time was 78 days (7,362 total catheter-days). There was no significant difference in overall duration of function (ie, survival) between silicone and polyurethane catheters (P = .12). The infection rates were 3.6 per 1,000 catheter-days for silicone catheters and 3.5 per 1,000 catheter-days for polyurethane catheters (P value not significant). CONCLUSIONS: There were fewer catheter fractures with the polyurethane catheter compared with the silicone catheter, although there was no difference in the total access site service interval for the two catheter types.


Assuntos
Cateterismo Venoso Central/instrumentação , Cateteres de Demora , Poliuretanos , Silicones , Infecções Relacionadas a Cateter/etiologia , Cateterismo Venoso Central/efeitos adversos , Cateteres de Demora/efeitos adversos , Desenho de Equipamento , Falha de Equipamento , Humanos , Infusões Intravenosas , Philadelphia , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo
17.
J Vasc Interv Radiol ; 22(5): 642-6; quiz 646, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21514518

RESUMO

PURPOSE: To compare the safety and effectiveness of over-the-wire catheter exchange (catheter-exchange) with catheter removal and replacement (removal-replacement) at a new site for infected or malfunctioning tunneled infusion catheters. MATERIALS AND METHODS: Using a quality assurance database, 61 patients with tunneled infusion catheters placed during the period July 2001 to June 2009 were included in this study. Patients receiving hemodialysis catheters were excluded. Catheter-exchange was performed in 25 patients, and same-day removal-replacement was performed in 36 patients. Data collected included demographic information, indication for initial catheter placement and replacement, dwell time for the new catheter, and ultimate fate of the new device. Statistical comparisons between the two cohorts were analyzed using the Kaplan-Meier technique and Fisher exact test. RESULTS: Catheters exchanged over the wire remained functional without infection for a median of 102 days (range, 2-570 days), whereas catheters removed and replaced were functional for a median 238 days (range, 1-292 days, P = .12). After catheter replacement, there were 11 instances of subsequent infection in the catheter-exchange group and 7 instances in the removal-replacement cohort, accounting for infection rates of 4.4 and 2.3 per 1,000 catheter days (P = .049). Patients in the catheter-exchange group had 3.2 greater odds of infection compared with patients in the removal-replacement group. Five malfunction events occurred in each group, accounting for 2.0 and 1.7 malfunctions per 1,000 catheter days in the catheter-exchange and removal-replacement groups (P = .73). CONCLUSIONS: Catheter-exchange of tunneled infusion catheters results in a higher infection rate compared with removal-replacement at a new site. The rate of catheter malfunction is not significantly different between the two groups. Catheter-exchange is an alternative for patients with tunneled infusion catheters who have limited venous access, but this technique should not be expanded for use in all patients. Because of the size of this initial study, further investigation is needed to verify the results in a larger sample size.


Assuntos
Infecções Relacionadas a Cateter/terapia , Cateterismo Venoso Central/efeitos adversos , Cateteres de Demora/efeitos adversos , Falha de Equipamento , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Infecções Relacionadas a Cateter/etiologia , Infecções Relacionadas a Cateter/mortalidade , Cateterismo Venoso Central/instrumentação , Cateterismo Venoso Central/mortalidade , Remoção de Dispositivo , Desenho de Equipamento , Feminino , Humanos , Infusões Intravenosas , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Philadelphia , Recidiva , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
18.
Radiology ; 256(1): 312-20, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20574104

RESUMO

PURPOSE: To prospectively evaluate outcomes associated with use of a triple-lumen (TL) peripherally inserted central catheter (PICC) in the intensive care unit (ICU) setting. MATERIALS AND METHODS: Patients were prospectively enrolled in this HIPAA-compliant, institutional review board-approved study. Informed consent was obtained. All patients were in one hospital's ICUs and needed intermediate-term central venous access requiring three lumina. A 6-F tapered TL PICC was placed by a bedside nursing-based team with backup from the Interventional Radiology department. Placement complications, as well as long-term complications, were recorded. At catheter removal, ultrasonography (US) of the veins containing the TL PICC was performed to detect occult venous thrombosis. Regardless of indication for removal, catheters were sent for culture to detect colonization. RESULTS: The study was stopped prematurely after 50 of a planned 167 patients were enrolled when a scheduled interim analysis detected a venous thrombosis rate that was considered unacceptably high by the study oversight committee (thrombosis was symptomatic in 20% of patients [10 of 50]). Venous thrombosis (symptomatic or asymptomatic) was detected in 26 of 45 patients (58%; 95% confidence interval [CI]: 43%, 72%) examined with US. Documented catheter-related bloodstream infection did not occur (0%; 95% CI: 0%, 7%); colonization was detected in three of 29 catheter tips sent for culture (10%; 95% CI: 2%, 27%). Catheter malfunction and dislodgment occurred in one patient each. CONCLUSION: The TL PICC design used in this study resulted in unacceptably high venous thrombosis rates. Even when used in a high-risk setting for infection (ie, the ICU), rates of clinically evident infection and colonization were absent and low, respectively.


Assuntos
Cateterismo Venoso Central/efeitos adversos , Cateterismo Venoso Central/instrumentação , Unidades de Terapia Intensiva , Trombose Venosa/diagnóstico por imagem , Trombose Venosa/etiologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Remoção de Dispositivo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Radiografia Intervencionista , Ultrassonografia
19.
J Vasc Interv Radiol ; 21(2): 203-11, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20036147

RESUMO

PURPOSE: To determine if a polyester cuff offered benefit in jugular small-bore central catheters (SBCCs). MATERIALS AND METHODS: Eighty-four patients were randomly assigned to receive a 5-F single- or 6-F dual-lumen SBCC with (n = 42) or without (n = 42) a polyester cuff. Follow-up was performed at 2 weeks, 1 month, and 3 months or at catheter removal, whichever came first. At scheduled follow-up, catheter function, patient satisfaction, and infection were determined. At catheter removal, tip culture was performed to determine colonization and jugular vein patency was determined with ultrasonography (US). RESULTS: The overall infection rate was 0.4 per 1,000 catheter days. There was one clinical infection (noncuffed catheter). Colonization occurred in two noncuffed catheters and one cuffed catheter. There was one catheter dislodgment in the noncuffed group and none in the cuffed group. Cuffed catheters were no more difficult to insert but took slightly longer to remove (6 minutes +/- 4.7 vs 5 minutes +/- 3, P = .39) and often required local anesthesia for removal, whereas noncuffed catheters did not (41% vs 0%, P = .001). Partial (two cuffed, 0 noncuffed) or complete (two cuffed, one noncuffed) jugular thrombosis was seen on five of 58 completion US studies (8.6%). CONCLUSIONS: A polyester cuff on a SBCC confers no significant benefit in short-term colonization rates. Infection in SBCCs is uncommon. Despite their small diameters, SBCCs can result in jugular thrombosis, an important consideration in any patient requiring long-term venous access.


Assuntos
Infecções Relacionadas a Cateter/etiologia , Cateterismo Venoso Central/instrumentação , Cateteres de Demora/efeitos adversos , Veias Jugulares , Nefropatias/terapia , Diálise Renal , Trombose Venosa/etiologia , Adulto , Idoso , Infecções Relacionadas a Cateter/diagnóstico por imagem , Infecções Relacionadas a Cateter/fisiopatologia , Cateterismo Venoso Central/efeitos adversos , Doença Crônica , Desenho de Equipamento , Feminino , Humanos , Veias Jugulares/diagnóstico por imagem , Veias Jugulares/fisiopatologia , Masculino , Pessoa de Meia-Idade , Satisfação do Paciente , Poliésteres , Estudos Prospectivos , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia , Grau de Desobstrução Vascular , Trombose Venosa/diagnóstico por imagem , Trombose Venosa/fisiopatologia , Adulto Jovem
20.
J Vasc Interv Radiol ; 21(3): 362-6, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20171558

RESUMO

PURPOSE: Synthetic mesh has revolutionized abdominal wall hernia repair. However, mesh infections present a clinical problem because the standard practice of surgical excision is fraught with increased morbidity. Here, single-institutional outcomes in managing mesh-related collections via percutaneous drainage are retrospectively reviewed to assess its effectiveness. MATERIALS AND METHODS: A total of 21 patients underwent drainage of perimesh collections. Three types of mesh were employed: polytetrafluoroethylene (PTFE; n = 5), polypropylene (n = 14), and porcine dermal collagen (n = 3). One patient received both polypropylene and PTFE. Drainage was performed with ultrasound guidance (n = 19) or surgical drain exchange (n = 2). Mesh type, culture results, fluid collection size, and location were analyzed with respect to need for mesh excision. RESULTS: Sixteen of 21 patients (76%) were successfully treated with drainage. One required additional surgical capsulectomy; the mesh was salvaged. Four required mesh excision because of recurrent infection (n = 2) or lack of improvement of clinical course (n = 2). Recurrent infection occurred in six patients, with mesh salvage via conservative management or new drainage in four. Fluid cultures were positive in 68% of patients (n = 13), with Staphylococcus aureus the most common organism. Cultures did not predict mesh excision (P = .26). The PTFE excision rate trended higher compared with polypropylene (40% vs 14%; P = .27). No porcine dermal collagen mesh was excised. Neither fluid collection size nor location predicted mesh excision. Mean follow-up was 319 days (range, 6-1,406 d). CONCLUSIONS: Percutaneous drainage of suspected mesh-related abscess is effective. The use of PTFE mesh trended toward a higher excision rate.


Assuntos
Drenagem/métodos , Hérnia/terapia , Infecções Relacionadas à Prótese/etiologia , Infecções Relacionadas à Prótese/prevenção & controle , Infecções Estafilocócicas/etiologia , Infecções Estafilocócicas/prevenção & controle , Telas Cirúrgicas/efeitos adversos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Hérnia/complicações , Humanos , Masculino , Pessoa de Meia-Idade , Infecções Relacionadas à Prótese/diagnóstico , Infecções Estafilocócicas/diagnóstico , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA