Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Rep Pract Oncol Radiother ; 26(6): 849-860, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34992856

RESUMO

BACKGROUND: The aim of this study was to investigate the performance of the RapidPlan (RP ) using models registered pseudostructures, and to determine how many structures are required for automatic optimization of volumetric modulated arc therapy (VMAT) for postoperative uterine cervical cancer. MATERIALS AND METHODS: Pseudo-structures around the PTV were retrospectively contoured for patients who had completed treatment at five institutions. For 22 common patients, plans were generated with a single optimization for models with two (RP_2), four (RP_4), and five (RP_5) registered structures, and the dosimetric parameters of these models were compared with a clinical plan with several optimizations. RESULTS: Most dosimetric parameters showed no major differences between each RP model. In particular, the rectum Dmax, V50Gy, and V40Gy with RP_2, RP_4, and RP_5 were not significantly different, and were lower than those of the clinical plan. The average proportions of plans achieving acceptable criteria for dosimetric parameters were close to 100% for all models. Using RP_2, the average time for the VMAT planning was reduced by 88 minutes compared with the clinical plan. CONCLUSION: The RapidPlan model with two registered pseudo-structures could generate clinically acceptable plans while saving time.

2.
J Chem Ecol ; 40(3): 250-8, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24633612

RESUMO

Females of the lichen moth, Miltochrista calamina (Arctiidae, Lithosiinae), were previously shown to produce 5-methylheptadecan-7-ol (1) as a sex pheromone. In field tests, males were attracted only by the (5R,7R)-isomer of the four stereoisomers that were prepared by separation from two mixtures of diastereoisomers. A new route to (5R,7R)-1 starting from (S)-propylene oxide was developed utilizing the SN2 reaction of an optically active secondary tosylate and the Jacobsen hydrolytic kinetic resolution of an epoxide intermediate as key steps. Enantioselective HPLC analysis of the product and the antipode synthesized from (R)-propylene oxide confirmed their high enantiomeric excess (> 99 %). Using this stereospecific synthesis, six analogues with the same configuration as (5R,7R)-1 but with different alkyl chain(s) connected to the stereogenic centers were prepared in order to obtain GC/MS data and to examine the ability of M. calamina males to discriminate between them. The mass spectra of the synthetic analogues revealed characteristic fragment ions derived by cleavage around the methyl group in addition to that at the hydroxyl group. In field trapping tests, five out of the six compounds were attractive to male M. calamina moths, indicating that the males distinguished the configurations of methyl and hydroxyl groups but were less able to perceive differences in the lengths of the two alkyl chains in the pheromone.


Assuntos
Álcoois Graxos/síntese química , Mariposas/química , Atrativos Sexuais/análise , Animais , Comportamento Animal/efeitos dos fármacos , Cromatografia Líquida de Alta Pressão , Álcoois Graxos/análise , Álcoois Graxos/farmacologia , Feminino , Cromatografia Gasosa-Espectrometria de Massas , Masculino , Mariposas/metabolismo , Atrativos Sexuais/síntese química , Atrativos Sexuais/farmacologia , Estereoisomerismo
3.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 69(10): 1130-9, 2013 Oct.
Artigo em Japonês | MEDLINE | ID: mdl-24140901

RESUMO

Multi-leaf collimators (MLCs) are used to modulate intensity during intensity modulated radiation therapy (IMRT). Evaluation of MLC movement in IMRT is important, since the accuracy of MLC movements affects the dose distribution. This evaluation is conventionally performed using an attached Dynalog File Viewer (DFV). However, due to its being an overall evaluation, it is not possible to discover significant errors. In this study, we developed software that permits easy analysis of MLC movements that can be used to retrospectively evaluate MLC movement during irradiation. We also evaluated the usefulness of our in-house program and confirmed its potential for use in clinical scenarios. We created a program that can read MLC logfiles using Visual Basic 6.0 and visualize the temporal changes and movements of the MLC. To evaluate our in-house program's efficacy in analyzing dynamic MLC-QA (quality assurance), we compared the numerical results yielded by our in-house program and the DFV. The results showed that our in-house program was able to reveal errors below the error root mean square (RMS) values obtained using the DFV. Using irregular surface compensator (ISC) irradiation conditions in a clinical context, we compared our in-house program with the DFV and, using RMS analysis, identified cases that showed excessive error. Our in-house program can also be used to investigate whether unacceptable errors are present, as well as their cause, when using the MLC, as it allows easy real-time observation and evaluation of MLC movements. An additional benefit is that collecting the MLC logfile during actual treatment also allows it to be evaluated retrospectively after continuous MLC operation.


Assuntos
Planejamento da Radioterapia Assistida por Computador/instrumentação , Radioterapia de Intensidade Modulada/instrumentação , Humanos , Garantia da Qualidade dos Cuidados de Saúde , Radiometria , Software
4.
Radiol Phys Technol ; 16(3): 366-372, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37248443

RESUMO

A calibration phantom made of Derlin requires manual translational and rotational adjustments when calibrating a light-section-based optical surface monitoring system (VOXELAN) with a phantom material that insufficiently reflects the red-slit laser of the system. This study aimed to develop a new calibration phantom using different materials and to propose a procedure that minimizes setup errors. The new phantom, primarily made of PET100, which exhibits good reflectivity without scattering or attenuating the red-slit laser at the phantom surface, was shaped in a manner similar to that of previous designs. The detection accuracy and stability were evaluated using six different regions of interest (ROIs) and compared with previous phantom designs. The coordinate coincidence between the machine and VOXELAN was compared for both phantom designs. The detection accuracy and stability of the new phantom in the reference ROI setting were found to be better than those of previous phantoms. In the lateral, longitudinal, and vertical directions, the coordinate coincidences in translational directions for the previous phantom were obtained at 1.07 ± 0.66, 1.46 ± 0.47, and 0.26 ± 0.83 mm, whereas those for the new phantom were obtained at 0.28 ± 0.21, 0.18 ± 0.30, and - 0.30 ± 0.29 mm, respectively. The rotational errors of the two phantoms were identical. The new phantom exhibited improved detection stability because of its good reflectivity. Additionally, the new placement procedure was linked to the six-degrees-of-freedom couch. A combination of the new phantom and its new placement procedure is suitable for coordinate calibration of VOXELAN.


Assuntos
Calibragem , Imagens de Fantasmas
5.
Anticancer Res ; 42(11): 5305-5314, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36288870

RESUMO

BACKGROUND/AIM: This study evaluated the impact of knowledge-based plan (KBP) model improvement on plan complexity and delivery accuracy in volumetric modulated arc therapy (VMAT) for prostate cancer at multiple institutions. MATERIALS AND METHODS: Five institutions created the first KBP model before April 2017 and subsequently devised a new model (second model) based on feedback from the first KBP and the efforts of planners after April 2019. The dose-volume histogram (DVH) parameters were validated for two prostate cancer cases between the first and second KBPs. Plan complexity metrics, of the modulation complexity score for VMAT (MCSv), closed leaf score (CLS), small aperture score (SAS), and leaf travel (LT), were compared. The delivery accuracy metrics of γ pass rate and point dose discrepancy (plan vs. measurement) at isocenter were also compared. RESULTS: There were no significant differences in DVH parameters between the KBPs. Conversely, V50% of the rectum and bladder was reduced in 6/10 and 8/10 patients, respectively, and these variations were also converged from the first KBP to the second KBP. The mean±1SDs of MCSv, CLS, SAS20mm, and LT (first KBP vs. second KBP) were 0.27±0.033 vs. 0.26±0.044, 0.062±0.032 vs. 0.14±0.091, 0.59±0.048 vs. 0.70±0.14, and 411.91±32.08 mm vs. 548.33±127.50 mm, respectively. The delivery accuracy did not differ, whereas MCSv was moderately correlated with the point dose discrepancy. CONCLUSION: Multi-leaf collimator motion could be more complex with KBP model improvement, which had the potential to deteriorate the delivery accuracy.


Assuntos
Neoplasias da Próstata , Radioterapia de Intensidade Modulada , Masculino , Humanos , Planejamento da Radioterapia Assistida por Computador , Dosagem Radioterapêutica , Neoplasias da Próstata/radioterapia , Raios gama
6.
Sci Rep ; 12(1): 15282, 2022 Sep 10.
Artigo em Inglês | MEDLINE | ID: mdl-36088382

RESUMO

We established a multi-institution model (big model) of knowledge-based treatment planning with over 500 treatment plans from five institutions in volumetric modulated arc therapy (VMAT) for prostate cancer. This study aimed to clarify the efficacy of using a large number of registered treatment plans for sharing the big model. The big model was created with 561 clinically approved VMAT plans for prostate cancer from five institutions (A: 150, B: 153, C: 49, D: 60, and E: 149) with different planning strategies. The dosimetric parameters of planning target volume (PTV), rectum, and bladder for two validation VMAT plans generated with the big model were compared with those from each institutional model (single-institution model). The goodness-of-fit of regression lines (R2 and χ2 values) and ratios of the outliers of Cook's distance (CD) > 4.0, modified Z-score (mZ) > 3.5, studentized residual (SR) > 3.0, and areal difference of estimate (dA) > 3.0 for regression scatter plots in the big model and single-institution model were also evaluated. The mean ± standard deviation (SD) of dosimetric parameters were as follows (big model vs. single-institution model): 79.0 ± 1.6 vs. 78.7 ± 0.5 (D50) and 0.13 ± 0.06 vs. 0.13 ± 0.07 (Homogeneity Index) for the PTV; 6.6 ± 4.0 vs. 8.4 ± 3.6 (V90) and 32.4 ± 3.8 vs. 46.6 ± 15.4 (V50) for the rectum; and 13.8 ± 1.8 vs. 13.3 ± 4.3 (V90) and 39.9 ± 2.0 vs. 38.4 ± 5.2 (V50) for the bladder. The R2 values in the big model were 0.251 and 0.755 for rectum and bladder, respectively, which were comparable to those from each institution model. The respective χ2 values in the big model were 1.009 and 1.002, which were closer to 1.0 than those from each institution model. The ratios of the outliers in the big model were also comparable to those from each institution model. The big model could generate a comparable VMAT plan quality compared with each single-institution model and therefore could possibly be shared with other institutions.


Assuntos
Neoplasias da Próstata , Radioterapia de Intensidade Modulada , Humanos , Masculino , Neoplasias da Próstata/radioterapia , Radiometria , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
7.
Radiol Phys Technol ; 13(4): 327-335, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32986184

RESUMO

Dosimetric evaluation and variation assessment were performed with two knowledge-based planning (KBP) models created at different periods for volumetric-modulated arc therapy (VMAT) for prostate cancer at five institutes. The first and second models (F- and S-models) for KBP were created before April 2017 and April 2019, respectively. The S-model was created using feedback plans from the F-model. Dose evaluation was compared between the two models using the same two computed tomography (CT) datasets and structures. The evaluation metrics were the dose received by 95.0% and 2.0% of the planning target volume (PTV); dose-volume parameters to the rectum and bladder as V90, V80, and V50; and monitor unit (MU). Dosimetric variation was compared by exporting estimated dose-volume histograms for each model to the Model Analytics website and assessing the organ at risk volume. There were no dosimetric differences between the two models for PTV. The V50 of the rectum in the S-model had improved compared to that of the F-model (case I: 49.3 ± 15.6 and 43.5 ± 15.2 [p = 0.08]; case II: 42.5 ± 16.9 and 36.0 ± 15.6 [p = 0.138]). The differences in other parameters were within ± 1.8% between the rectum and the bladder. The MU was slightly higher in the S-model than in the F-model, and dosimetric variation was reduced to the rectum and bladder among all the institutes. The polished S-model for KBP could be used for standardization of the plan quality and sharing of KBP models in VMAT for prostate cancer.


Assuntos
Neoplasias da Próstata , Radioterapia de Intensidade Modulada , Humanos , Masculino , Órgãos em Risco , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA