Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Anal Chem ; 94(20): 7339-7349, 2022 05 24.
Artigo em Inglês | MEDLINE | ID: mdl-35549087

RESUMO

Large RNA including mRNA (mRNA) has emerged as an important new class of therapeutics. Recently, this has been demonstrated by two highly efficacious vaccines based on mRNA sequences encoding for a modified version of the SARS-CoV-2 spike protein. There is currently significant demand for the development of new and improved analytical methods for the characterization of large RNA including mRNA therapeutics. In this study, we have developed an automated, high-throughput workflow for the rapid characterization and direct sequence mapping of large RNA and mRNA therapeutics. Partial RNase digestions using RNase T1 immobilized on magnetic particles were performed in conjunction with high-resolution liquid chromatography-mass spectrometry analysis. Sequence mapping was performed using automated oligoribonucleotide annotation and identifications based on MS/MS spectra. Using this approach, a >80% sequence of coverage of a range of large RNAs and mRNA therapeutics including the SARS-CoV-2 spike protein was obtained in a single analysis. The analytical workflow, including automated sample preparation, can be completed within 90 min. The ability to rapidly identify, characterize, and sequence map large mRNA therapeutics with high sequence coverage provides important information for identity testing, sequence validation, and impurity analysis.


Assuntos
COVID-19 , Espectrometria de Massas em Tandem , COVID-19/terapia , Humanos , RNA/química , RNA Mensageiro/genética , SARS-CoV-2/genética , Glicoproteína da Espícula de Coronavírus , Espectrometria de Massas em Tandem/métodos
2.
Anal Chem ; 90(3): 1870-1880, 2018 02 06.
Artigo em Inglês | MEDLINE | ID: mdl-29276835

RESUMO

For LC-MS-based targeted quantification of biotherapeutics and biomarkers in clinical and pharmaceutical environments, high sensitivity, high throughput, and excellent robustness are all essential but remain challenging. For example, though nano-LC-MS has been employed to enhance analytical sensitivity, it falls short because of its low loading capacity, poor throughput, and low operational robustness. Furthermore, high chemical noise in protein bioanalysis typically limits the sensitivity. Here we describe a novel trapping-micro-LC-MS (T-µLC-MS) strategy for targeted protein bioanalysis, which achieves high sensitivity with exceptional robustness and high throughput. A rapid, high-capacity trapping of biological samples is followed by µLC-MS analysis; dynamic sample trapping and cleanup are performed using pH, column chemistry, and fluid mechanics separate from the µLC-MS analysis, enabling orthogonality, which contributes to the reduction of chemical noise and thus results in improved sensitivity. Typically, the selective-trapping and -delivery approach strategically removes >85% of the matrix peptides and detrimental components, markedly enhancing sensitivity, throughput, and operational robustness, and narrow-window-isolation selected-reaction monitoring further improves the signal-to-noise ratio. In addition, unique LC-hardware setups and flow approaches eliminate gradient shock and achieve effective peak compression, enabling highly sensitive analyses of plasma or tissue samples without band broadening. In this study, the quantification of 10 biotherapeutics and biomarkers in plasma and tissues was employed for method development. As observed, a significant sensitivity gain (up to 25-fold) compared with that of conventional LC-MS was achieved, although the average run time was only 8 min/sample. No appreciable peak deterioration or loss of sensitivity was observed after >1500 injections of tissue and plasma samples. The developed method enabled, for the first time, ultrasensitive LC-MS quantification of low levels of a monoclonal antibody and antigen in a tumor and cardiac troponin I in plasma after brief cardiac ischemia. This strategy is valuable when highly sensitive protein quantification in large sample sets is required, as is often the case in typical biomarker validation and pharmaceutical investigations of antibody therapeutics.


Assuntos
Cromatografia Líquida/instrumentação , Ensaios de Triagem em Larga Escala/instrumentação , Espectrometria de Massas/instrumentação , Peptídeos/análise , Proteínas/análise , Sequência de Aminoácidos , Animais , Anticorpos Monoclonais/análise , Biomarcadores/análise , Cromatografia Líquida/economia , Cromatografia Líquida/métodos , Desenho de Equipamento , Ensaios de Triagem em Larga Escala/economia , Ensaios de Triagem em Larga Escala/métodos , Humanos , Imunoglobulina G/análise , Limite de Detecção , Espectrometria de Massas/economia , Espectrometria de Massas/métodos , Camundongos , Ratos , Suínos
3.
Rapid Commun Mass Spectrom ; 27(7): 731-7, 2013 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-23495019

RESUMO

RATIONALE: Multiplexed liquid chromatography (LC) coupled with multiple-injection-chromatogram acquisition has emerged as the method of choice for high-speed discovery bioanalysis, because it significantly reduces injection-to-injection cycle time while maintaining the chromatography quality. Historically, systems utilizing this approach had been custom built, and therefore relied on custom software tools to communicate with multiple vendor software for system control, which lacked transferability, flexibility and robustness. METHODS: In this study, we refined a multiplexed bioanalytical system previously reported, by implementing open-deck auto-sampler manifold and multiple-injection-chromatogram acquisition, all on a commercially available system with single software control. RESULTS: As a result of these improvements, the developed LC/tandem mass spectrometry (MS/MS) method on the system was nearly three times faster than the previous method, while demonstrating comparable analytical accuracy, precision and robustness. This system has been evaluated for in vitro ADME screening assays including metabolic stability, CYP inhibition and Caco-2. The biological data generated on the developed system displayed good correlation with those from the previous LC/MS/MS approaches. CONCLUSIONS: The developed platform demonstrated applicability to the in vitro screening assays evaluated and has been successfully implemented to support the high-throughput metabolic stability assay, with a significantly improved bioanalytical throughput, capacity and data turnaround.


Assuntos
Cromatografia Líquida/métodos , Descoberta de Drogas/métodos , Software , Espectrometria de Massas em Tandem/métodos , Animais , Células CACO-2 , Cromatografia Líquida/instrumentação , Citocromo P-450 CYP3A/análise , Citocromo P-450 CYP3A/metabolismo , Humanos , Modelos Lineares , Camundongos , Modelos Químicos , Propranolol/análise , Propranolol/química , Ratos , Reprodutibilidade dos Testes
4.
Bioanalysis ; 4(9): 1013-24, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22612683

RESUMO

BACKGROUND: High-throughput screening with LC-MS has been routinely implemented to various degrees throughout the entire drug-discovery process. One of the major advantages of utilizing LC-MS earlier at the lead discovery stage is reducing the cost of sample analysis while increasing assay selectivity. Avoiding labeling agents and other non-native species in an assay environment can reduce costly sample preparation, while chromatographic separation of the analyte of interest from interferences in the sample matrix has been shown to increase selectivity and sensitivity. METHOD: In this paper, we utilize high-resolution MS-LC multiplexing to analyze phosphorylated peptides as part of a screening assay. Commonly used enzyme buffers were used to prepare phosphorylated peptide standards of varying concentrations and these were plated into a 96-well plate format for LC-MS analysis. The overall cycle time for analysis from sample to sample, LLOQ, Z' and coefficient of variance were determined. CONCLUSION: High-resolution MS coupled with LC multiplexing provides high-quality sample analysis at sampling rates of up to 18 s per sample. Samples analyzed in both simple and complex sample matrixes demonstrated an LOQ of 5 nM with linear response across the working range of the assay. Overall statistical analysis of the large samples produced Z' = 0.85 for sample sets in sodium citrate solution and Z' = 0.66 for sample sets in HEPES solution indicating a robust analytical method.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Espectrometria de Massas/métodos , Soluções Tampão , Cromatografia Líquida de Alta Pressão/instrumentação , Avaliação Pré-Clínica de Medicamentos , Enzimas/metabolismo , Ensaios de Triagem em Larga Escala , Espectrometria de Massas/instrumentação , Fosfopeptídeos/análise , Software , Fatores de Tempo
5.
Bioanalysis ; 4(11): 1327-35, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22720651

RESUMO

BACKGROUND: Laser diode thermal desorption (LDTD) is a relatively new sample introduction interface for MS. Analysis times are short as the technique does not require time-consuming separation steps, such as conventional HPLC, thus saving on the use of organic solvents, modifiers and cost, relating to their subsequent disposal. This paper compares the merits of LDTD-APCI-MS/MS and LC-MS/MS for the analysis of paracetamol (acetaminophen) in plasma from different species. RESULTS: LDTD-APCI-MS/MS compared favorably with our existing high-throughput generic LC-MS/MS method giving improved data quality. LDTD-APCI-MS/MS assay performance in terms of accuracy and precision in mouse, rat and dog plasma were within our local acceptance criteria (±30%). Run times were reduced approximately tenfold, while saving approximately 200 ml of solvent per 96-well plate. CONCLUSION: A rapid, sensitive and robust assay is reported. The method was successfully used for the analysis of spiked mouse, rat and dog plasma samples and the determination of oral pharmacokinetics. Reductions in electrical power and reagent consumption position LDTD as an environmentally 'green' bioanalytical method.


Assuntos
Acetaminofen/sangue , Cromatografia Líquida de Alta Pressão , Espectrometria de Massas em Tandem , Administração Oral , Animais , Cães , Lasers , Masculino , Camundongos , Ratos , Ratos Wistar , Temperatura
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA