Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros

País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Magn Reson Med ; 73(2): 623-32, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24639022

RESUMO

PURPOSE: Optimization of sequence and sequence parameters to allow three-dimensional (3D) sodium imaging of the entire human heart in vivo in a clinically reasonable time. THEORY AND METHODS: A stack of spirals pulse sequence was optimized for cardiac imaging by considering factors such as spoiling, nutation angles, repetition time, echo time, T1/T2 relaxation, off-resonance, data acquisition window, motion, and segmented k-space acquisition. Simulations based on Bloch equations as well as the exact trajectory used for data acquisition provided the basis for choice of parameter combinations for sodium imaging. Sodium phantom scanning was used to validate the choice of parameters and for corroboration with simulations. In vivo cardiac imaging in six volunteers was also performed with an optimized sequence. RESULTS: Phantom studies showed good correlation with simulation results. Images obtained from human volunteers showed that the heart can be imaged with a nominal resolution of 5 × 5 × 10 mm(3) and with a signal-to-noise ratio >15 (in the septum) in about 6-10 minutes. Long axis views of the reformatted human heart show true 3D imaging capability. CONCLUSION: Optimization of the sequence and its parameters allowed in vivo 3D sodium imaging of the entire human heart in a clinically reasonable time.


Assuntos
Aumento da Imagem/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Imagem Molecular/métodos , Miocárdio/metabolismo , Sódio/metabolismo , Algoritmos , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
JAMA ; 314(18): 1945-54, 2015 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-26547466

RESUMO

IMPORTANCE: Myocardial scarring leads to cardiac dysfunction and poor prognosis. The prevalence of and factors associated with unrecognized myocardial infarction and scar have not been previously defined using contemporary methods in a multiethnic US population. OBJECTIVE: To determine prevalence of and factors associated with myocardial scar in middle- and older-aged individuals in the United States. DESIGN, SETTING, AND PARTICIPANTS: The Multi-Ethnic Study of Atherosclerosis (MESA) study is a population-based cohort in the United States. Participants were aged 45 through 84 years and free of clinical cardiovascular disease (CVD) at baseline in 2000-2002. In the 10th year examination (2010-2012), 1840 participants underwent cardiac magnetic resonance (CMR) imaging with gadolinium to detect myocardial scar. Cardiovascular disease risk factors and coronary artery calcium (CAC) scores were measured at baseline and year 10. Logistic regression models were used to estimate adjusted odds ratios (ORs) for myocardial scar. EXPOSURES: Cardiovascular risk factors, CAC scores, left ventricle size and function, and carotid intima-media thickness. MAIN OUTCOMES AND MEASURES: Myocardial scar detected by CMR imaging. RESULTS: Of 1840 participants (mean [SD] age, 68 [9] years, 52% men), 146 (7.9%) had myocardial scars, of which 114 (78%) were undetected by electrocardiogram or by clinical adjudication. In adjusted models, age, male sex, body mass index, hypertension, and current smoking at baseline were associated with myocardial scar at year 10. The OR per 8.9-year increment was 1.61 (95% CI, 1.36-1.91; P < .001); for men vs women: OR, 5.76 (95% CI, 3.61-9.17; P < .001); per 4.8-SD body mass index: OR, 1.32 (95% CI, 1.09-1.61, P = .005); for hypertension: OR, 1.61 (95% CI, 1.12-2.30; P = .009); and for current vs never smokers: 2.00 (95% CI, 1.22-3.28; P = .006). Age-, sex-, and ethnicity-adjusted CAC scores at baseline were also associated with myocardial scar at year 10. Compared with a CAC score of 0, the OR for scores from 1 through 99 was 2.4 (95% CI, 1.5-3.9); from 100 through 399, 3.0 (95% CI, 1.7-5.1), and 400 or higher, 3.3 (95% CI, 1.7-6.1) (P ≤ .001). The CAC score significantly added to the association of myocardial scar with age, sex, race/ethnicity, and traditional CVD risk factors (C statistic, 0.81 with CAC vs 0.79 without CAC, P = .01). CONCLUSIONS AND RELEVANCE: The prevalence of myocardial scars in a US community-based multiethnic cohort was 7.9%, of which 78% were unrecognized by electrocardiography or clinical evaluation. Further studies are needed to understand the clinical consequences of these undetected scars.


Assuntos
Cardiomiopatias/epidemiologia , Cicatriz/epidemiologia , Idoso , Idoso de 80 Anos ou mais , População Negra , Índice de Massa Corporal , Calcinose/diagnóstico , Calcinose/epidemiologia , Cardiomiopatias/diagnóstico , Cardiomiopatias/etnologia , Cardiomiopatias/etiologia , Doenças Cardiovasculares/diagnóstico , China/etnologia , Cicatriz/diagnóstico , Cicatriz/etnologia , Cicatriz/etiologia , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/epidemiologia , Feminino , Gadolínio , Hispânico ou Latino , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/complicações , Infarto do Miocárdio/epidemiologia , Prevalência , Análise de Regressão , Fatores de Tempo , Estados Unidos , População Branca
3.
J Cardiovasc Magn Reson ; 14: 18, 2012 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-22376193

RESUMO

PURPOSE: Myocardial late gadolinium enhancement was originally validated using higher than label-recommended doses of gadolinium chelate. The objective of this study was to evaluate available evidence for various gadolinium dosing regimens used for CMR. The relationship of gadolinium dose warnings (due to nephrogenic systemic fibrosis) announced in 2008 to gadolinium dosing regimens was also examined. METHODS: We conducted a meta-analysis of peer reviewed publications from January, 2004 to December, 2010. Major subject search headings (MeSh) terms from the National Library of Medicine's PubMed were: contrast media, gadolinium, heart, magnetic resonance imaging; searches were limited to human studies with abstracts published in English. Case reports, review articles, editorials, MRA related papers and all reports that did not indicate gadolinium type or weight-based dose were excluded. For all included references, full text was available to determine the total administered gadolinium dose on a per kg basis. Average and median dose values were weighted by the number of subjects in each study. RESULTS: 399 publications were identified in PubMed; 233 studies matched the inclusion criteria, encompassing 19,934 patients with mean age 54.2 ± 11.4 (range 9.3 to 76 years). 34 trials were related to perfusion testing and 199 to myocardial late gadolinium enhancement. In 2004, the weighted-median and weighted-mean contrast dose were 0.15 and 0.16 ± 0.06 mmol/kg, respectively. Median contrast doses for 2005-2010 were: 0.2 mmol/kg for all years, respectively. Mean contrast doses for the years 2005-2010 were: 0.19 ± 0.03, 0.18 ± 0.04, 0.18 ± 0.10, 0.18 ± 0.03, 0.18 ± 0.04 and 0.18 ± 0.04 mmol/kg, respectively (p for trend, NS). Gadopentetate dimeglumine was the most frequent gadolinium type [114 (48.9%) studies]. No change in mean gadolinium dose was present before, versus after the Food and Drug Administration (FDA) black box warning (p > 0.05). Three multi-center dose ranging trials have been published for cardiac MRI applications. CONCLUSION: CMR studies in the peer-reviewed published literature routinely use higher gadolinium doses than regulatory agencies indicated in the package leaflet. Clinical trials should be supported to determine the appropriate doses of gadolinium for CMR studies.


Assuntos
Doenças Cardiovasculares/diagnóstico , Meios de Contraste/normas , Gadolínio/normas , Imageamento por Ressonância Magnética/normas , Dermopatia Fibrosante Nefrogênica/prevenção & controle , United States Food and Drug Administration/normas , Adolescente , Adulto , Idoso , Criança , Meios de Contraste/administração & dosagem , Meios de Contraste/efeitos adversos , Relação Dose-Resposta a Droga , Rotulagem de Medicamentos/normas , Gadolínio/administração & dosagem , Gadolínio/efeitos adversos , Fidelidade a Diretrizes , Humanos , Pessoa de Meia-Idade , Dermopatia Fibrosante Nefrogênica/induzido quimicamente , Guias de Prática Clínica como Assunto , Medição de Risco , Fatores de Risco , Estados Unidos , Adulto Jovem
4.
J Cardiovasc Magn Reson ; 14: 17, 2012 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-22348519

RESUMO

Hypertrophic cardiomyopathy (HCM) is the most common genetic disease of the heart. HCM is characterized by a wide range of clinical expression, ranging from asymptomatic mutation carriers to sudden cardiac death as the first manifestation of the disease. Over 1000 mutations have been identified, classically in genes encoding sarcomeric proteins. Noninvasive imaging is central to the diagnosis of HCM and cardiovascular magnetic resonance (CMR) is increasingly used to characterize morphologic, functional and tissue abnormalities associated with HCM. The purpose of this review is to provide an overview of the clinical, pathological and imaging features relevant to understanding the diagnosis of HCM. The early and overt phenotypic expression of disease that may be identified by CMR is reviewed. Diastolic dysfunction may be an early marker of the disease, present in mutation carriers prior to the development of left ventricular hypertrophy (LVH). Late gadolinium enhancement by CMR is present in approximately 60% of HCM patients with LVH and may provide novel information regarding risk stratification in HCM. It is likely that integrating genetic advances with enhanced phenotypic characterization of HCM with novel CMR techniques will importantly improve our understanding of this complex disease.


Assuntos
Cardiomiopatia Hipertrófica Familiar/diagnóstico , Imageamento por Ressonância Magnética , Miocárdio/patologia , Cardiomiopatia Hipertrófica Familiar/complicações , Cardiomiopatia Hipertrófica Familiar/genética , Cardiomiopatia Hipertrófica Familiar/patologia , Cardiomiopatia Hipertrófica Familiar/fisiopatologia , Meios de Contraste , Morte Súbita Cardíaca/etiologia , Progressão da Doença , Fibrose , Predisposição Genética para Doença , Humanos , Hipertrofia Ventricular Esquerda/diagnóstico , Hipertrofia Ventricular Esquerda/genética , Hipertrofia Ventricular Esquerda/fisiopatologia , Fenótipo , Valor Preditivo dos Testes , Prognóstico , Função Ventricular Esquerda
5.
J Cardiovasc Magn Reson ; 14: 90, 2012 Dec 28.
Artigo em Inglês | MEDLINE | ID: mdl-23272704

RESUMO

BACKGROUND: Cardiac magnetic resonance (CMR) T1 mapping has been used to characterize myocardial diffuse fibrosis. The aim of this study is to determine the reproducibility and sample size of CMR fibrosis measurements that would be applicable in clinical trials. METHODS: A modified Look-Locker with inversion recovery (MOLLI) sequence was used to determine myocardial T1 values pre-, and 12 and 25min post-administration of a gadolinium-based contrast agent at 3 Tesla. For 24 healthy subjects (8 men; 29 ± 6 years), two separate scans were obtained a) with a bolus of 0.15mmol/kg of gadopentate dimeglumine and b) 0.1mmol/kg of gadobenate dimeglumine, respectively, with averaged of 51 ± 34 days between two scans. Separately, 25 heart failure subjects (12 men; 63 ± 14 years), were evaluated after a bolus of 0.15mmol/kg of gadopentate dimeglumine. Myocardial partition coefficient (λ) was calculated according to (ΔR1myocardium/ΔR1blood), and ECV was derived from λ by adjusting (1-hematocrit). RESULTS: Mean ECV and λ were both significantly higher in HF subjects than healthy (ECV: 0.287 ± 0.034 vs. 0.267 ± 0.028, p=0.002; λ: 0.481 ± 0.052 vs. 442 ± 0.037, p < 0.001, respectively). The inter-study ECV and λ variation were about 2.8 times greater than the intra-study ECV and λ variation in healthy subjects (ECV:0.017 vs. 0.006, λ:0.025 vs. 0.009, respectively). The estimated sample size to detect ECV change of 0.038 or λ change of 0.063 (corresponding to ~3% increase of histological myocardial fibrosis) with a power of 80% and an alpha error of 0.05 for heart failure subjects using a two group design was 27 in each group, respectively. CONCLUSION: ECV and λ quantification have a low variability across scans, and could be a viable tool for evaluating clinical trial outcome.


Assuntos
Ensaios Clínicos como Assunto/métodos , Insuficiência Cardíaca/diagnóstico , Imageamento por Ressonância Magnética , Miocárdio/patologia , Adulto , Idoso , Análise de Variância , Estudos de Casos e Controles , Meios de Contraste , Feminino , Fibrose , Insuficiência Cardíaca/patologia , Humanos , Masculino , Meglumina/análogos & derivados , Pessoa de Meia-Idade , Compostos Organometálicos , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Tamanho da Amostra , Fatores de Tempo , Adulto Jovem
6.
J Cardiovasc Magn Reson ; 13: 75, 2011 Nov 28.
Artigo em Inglês | MEDLINE | ID: mdl-22123333

RESUMO

BACKGROUND: To compare 11 heartbeat (HB) and 17 HB modified lock locker inversion recovery (MOLLI) pulse sequence at 3T and to establish preliminary reference values for myocardial T1 and the extracellular volume fraction (ECV). METHODS: Both phantoms and normal volunteers were scanned at 3T using 11 HB and 17 HB MOLLI sequence with the following parameters: spatial resolution = 1.75 × 1.75 × 10 mm on a 256 × 180 matrix, TI initial = 110 ms, TI increment = 80 ms, flip angle = 35°, TR/TE = 1.9/1.0 ms. All volunteers were administered Gadolinium-DTPA (Magnevist, 0.15 mmol/kg), and multiple post-contrast MOLLI scans were performed at the same pre-contrast position from 3.5-23.5 minutes after a bolus contrast injection. Late gadolinium enhancement (LGE) images were also acquired 12-30 minutes after the gadolinium bolus. RESULTS: T1 values of 11 HB and 17 HB MOLLI displayed good agreement in both phantom and volunteers. The average pre-contrast myocardial and blood T1 was 1315 ± 39 ms and 2020 ± 129 ms, respectively. ECV was stable between 8.5 to 23.5 minutes post contrast with an average of 26.7 ± 1.0%. CONCLUSION: The 11 HB MOLLI is a faster method for high-resolution myocardial T1 mapping at 3T. ECV fractions are stable over a wide time range after contrast administration.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca , Coração/anatomia & histologia , Imageamento por Ressonância Magnética , Miocárdio , Adulto , Técnicas de Imagem de Sincronização Cardíaca/instrumentação , Técnicas de Imagem de Sincronização Cardíaca/normas , Meios de Contraste , Eletrocardiografia , Feminino , Gadolínio DTPA , Frequência Cardíaca , Humanos , Modelos Lineares , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/normas , Masculino , Maryland , Pessoa de Meia-Idade , Imagens de Fantasmas , Valor Preditivo dos Testes , Valores de Referência , Reprodutibilidade dos Testes , Adulto Jovem
7.
Arq Bras Cardiol ; 108(6): 552-563, 2017.
Artigo em Inglês, Português | MEDLINE | ID: mdl-28562831

RESUMO

BACKGROUND:: Cardiac Magnetic Resonance is in need of a simple and robust method for diastolic function assessment that can be done with routine protocol sequences. OBJECTIVE:: To develop and validate a three-dimensional (3D) model-based volumetric assessment of diastolic function using cardiac magnetic resonance (CMR) imaging and compare the results obtained with the model with those obtained by echocardiography. METHODS:: The study participants provided written informed consent and were included if having undergone both echocardiography and cine steady-state free precession (SSFP) CMR on the same day. Guide points at the septal and lateral mitral annulus were used to define the early longitudinal relaxation rate (E'), while a time-volume curve from the 3D model was used to assess diastolic filling parameters. We determined the correlation between 3D CMR and echocardiography and the accuracy of CMR in classifying the diastolic function grade. RESULTS:: The study included 102 subjects. The E/A ratio by CMR was positively associated with the E/A ratio by echocardiography (r = 0.71, p < 0.0001). The early diastolic relaxation velocity by tissue Doppler and longitudinal relaxation rate for the lateral mitral annulus displacement were positively associated (p = 0.007), as were the ratio between Doppler E/e' and CMR E/E' (p = 0.01). CMR-determined normalized peak E (NE) and deceleration time (DT) were able to predict diastolic dysfunction (areas under the curve [AUCs] = 0.70 and 0.72, respectively). In addition, the lateral E/E' ratio showed good utility in identifying diastolic dysfunction (AUC = 0.80). Overall, echocardiography and CMR interobserver and intraobserver agreements were excellent (intraclass correlation coefficient range 0.72 - 0.97). CONCLUSION:: 3D modeling of standard cine CMR images was able to identify study subjects with reduced diastolic function and showed good reproducibility, suggesting a potential for a routine diastolic function assessment by CMR. FUNDAMENTO:: A ressonância magnética cardíaca necessita de um método simples e robusto para a avaliação da função diastólica que pode ser feito com sequências protocolares de rotina. OBJETIVO:: Desenvolver e validar a avaliação volumétrica da função diastólica através de um modelo tridimensional (3D) com utilização de imagens de ressonância magnética cardíaca (RMC) e comparar os resultados obtidos com este modelo com os obtidos por ecocardiografia. MÉTODOS:: Os participantes do estudo assinaram um termo de consentimento e foram incluídos se tivessem sido submetidos no mesmo dia tanto à ecocardiografia quanto à cine RMC com precessão livre no estado estacionário (steady-state free precession, SSFP). Pontos-guia foram utilizados no anel mitral septal e lateral para definir a velocidade de estiramento no início da diástole (E'), enquanto curvas de volume-tempo do modelo 3D foram utilizadas para avaliar os parâmetros de enchimento diastólico. Foram determinadas a correlação entre a RMC 3D e a ecocardiografia, além da acurácia da RMC em classificar o grau de função diastólica. RESULTADOS:: Ao todo, 102 sujeitos foram incluídos no estudo. A razão E/A pela RMC esteve positivamente associada com a razão E/A obtida pela ecocardiografia (r = 0,71, p < 0,0001). Estiveram positivamente associadas a velocidade de relaxamento diastólico inicial ao Doppler tecidual e a velocidade de relaxamento longitudinal de deslocamento do anel mitral lateral (p = 0,007), bem como a razão entre E/e' por Doppler e E/E' pela RMC (p = 0,01). A velocidade normalizada de pico de enchimento (EM) determinada pela RMC e o tempo de desaceleração (TD) foram capazes de predizer a disfunção diastólica (áreas sob a curva [AUCs] = 0,70 e 0,72, respectivamente). Além disso, a razão E/E' lateral mostrou boa utilidade para a identificação da disfunção diastólica (AUC = 0,80). No geral, a ecocardiografia e a RMC apresentaram excelente concordância interobservador e intraobservador (coeficiente de correlação intraclasse 0,72 - 0,97). CONCLUSÃO:: Uma modelagem 3D de imagens padrões de cine RMC foi capaz de identificar os indivíduos do estudo com função diastólica reduzida e mostrou uma boa reprodutibilidade, sugerindo ter potencial na avaliação rotineira da função diastólica por RMC.


Assuntos
Aterosclerose/diagnóstico por imagem , Volume Sistólico/fisiologia , Idoso , Idoso de 80 Anos ou mais , Aterosclerose/fisiopatologia , Diástole/fisiologia , Ecocardiografia , Feminino , Humanos , Imageamento Tridimensional , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes
8.
Int J Cardiovasc Imaging ; 29(5): 1085-94, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23515949

RESUMO

Gadolinium enhanced coronary magnetic resonance angiography (MRA) at 3 T appears to be superior to non-contrast methods. Gadofosveset is an intravascular contrast agent that may be well suited to this application. The purpose of this study was to perform an intra-individual comparison of gadofosveset and gadobenate for coronary MRA at 3 T. In this prospective randomized study, 22 study subjects [8 (36%) male; 27.9 ± 6 years; BMI = 22.8 ± 2 kg/m(2)] underwent two studies using a contrast-enhanced inversion recovery three-dimensional fast low angle shot MRA at 3 T. The order of contrast agent administration was varied randomly, separated by an average of 30 ± 5 days, using either gadobenate dimeglumine (Gd-BOPTA; Bracco, 0.1 mmol/Kg) or gadofosveset trisodium (MS-325; Lantheus Med, 0.03 mmol/Kg). Acquisition time, signal-to-noise ratio (SNR) of coronary vessels and contrast-to-noise ratio (CNR) were evaluated. Of 308 coronary arteries and veins segment analyzed, overall SNR of coronary arteries and veins segments were not different for the two contrast agents (132 ± 79 for gadofosveset vs. 135 ± 78 for gadobenate, p = 0.69). Coronary artery CNR was greater for gadofosveset in comparison to gadobenate (73.5 ± 46.9 vs. 59.3 ± 75.7 respectively, p = 0.03). Gadofosveset-enhanced MRA images displayed better image quality than gadobenate-enhanced MRA images (2.77 ± 0.61 for gadofosveset vs. 2.11 ± 0.51, p < .001). Inter- and intra-reader variability was excellent (ICC > 0.90) for both contrast agents. Gadofosveset trisodium appears to show slightly better performance for coronary MRA at 3 T compared to gadobenate.


Assuntos
Meios de Contraste , Vasos Coronários/anatomia & histologia , Gadolínio , Angiografia por Ressonância Magnética/métodos , Meglumina/análogos & derivados , Compostos Organometálicos , Adulto , Feminino , Voluntários Saudáveis , Humanos , Masculino , Maryland , Variações Dependentes do Observador , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Razão Sinal-Ruído , Adulto Jovem
9.
Med Phys ; 40(10): 103501, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24089934

RESUMO

PURPOSE: Myocardial extracellular volume fraction (ECVF) is a surrogate imaging biomarker of diffuse myocardial fibrosis, a hallmark of pathologic ventricular remodeling. Low dose cardiac CT is emerging as a promising modality to detect diffuse interstitial myocardial fibrosis due to its fast acquisition and low radiation; however, the insufficient contrast in the low dose CT images poses great challenge to measure ECVF from the image. METHODS: To deal with this difficulty, the authors present a complete ECVF measurement framework including a point-guided myocardial modeling, a deformable model-based myocardium segmentation, nonrigid registration of pre- and post-CT, and ECVF calculation. RESULTS: The proposed method was evaluated on 20 patients by two observers. Compared to the manually delineated reference segmentations, the accuracy of our segmentation in terms of true positive volume fraction (TPVF), false positive volume fraction (FPVF), and average surface distance (ASD), were 92.18% ± 3.52%, 0.31% ± 0.10%, 0.69 ± 0.14 mm, respectively. The interobserver variability measured by concordance correlation coefficient regarding TPVF, FPVF, and ASD were 0.95, 0.90, 0.94, respectively, demonstrating excellent agreement. Bland-Altman method showed 95% limits of agreement between ECVF at CT and ECVF at MR. CONCLUSIONS: The proposed framework demonstrates its efficiency, accuracy, and noninvasiveness in ECVF measurement and dramatically advances the ECVF at cardiac CT toward its clinical use.


Assuntos
Espaço Extracelular/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Miocárdio/citologia , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
10.
IEEE Trans Inf Technol Biomed ; 16(5): 842-51, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22711778

RESUMO

Cardiac CT (CCT) is widely available and has been validated for the detection of focal myocardial scar using a delayed enhancement technique in this paper. CCT, however, has not been previously evaluated for quantification of diffuse myocardial fibrosis. In our investigation, we sought to evaluate the potential of low-dose CCT for the measurement of myocardial whole heart extracellular volume (ECV) fraction. ECV is altered under conditions of increased myocardial fibrosis. A framework consisting of three main steps was proposed for CCT whole heart ECV estimation. First, a shape-constrained graph cut (GC) method was proposed for myocardium and blood pool segmentation on postcontrast image. Second, the symmetric demons deformable registration method was applied to register precontrast to postcontrast images. So the correspondences between the voxels from precontrast to postcontrast images were established. Finally, the whole heart ECV value was computed. The proposed method was tested on 20 clinical low-dose CCT datasets with precontrast and postcontrast images. The preliminary results demonstrated the feasibility and efficiency of the proposed method.


Assuntos
Técnicas de Diagnóstico Cardiovascular , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/patologia , Coração/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Miocárdio/patologia , Análise de Regressão , Reprodutibilidade dos Testes
11.
Arq. bras. cardiol ; 108(6): 552-563, June 2017. tab, graf
Artigo em Inglês | LILACS | ID: biblio-887879

RESUMO

Abstract Background: Cardiac Magnetic Resonance is in need of a simple and robust method for diastolic function assessment that can be done with routine protocol sequences. Objective: To develop and validate a three-dimensional (3D) model-based volumetric assessment of diastolic function using cardiac magnetic resonance (CMR) imaging and compare the results obtained with the model with those obtained by echocardiography. Methods: The study participants provided written informed consent and were included if having undergone both echocardiography and cine steady-state free precession (SSFP) CMR on the same day. Guide points at the septal and lateral mitral annulus were used to define the early longitudinal relaxation rate (E'), while a time-volume curve from the 3D model was used to assess diastolic filling parameters. We determined the correlation between 3D CMR and echocardiography and the accuracy of CMR in classifying the diastolic function grade. Results: The study included 102 subjects. The E/A ratio by CMR was positively associated with the E/A ratio by echocardiography (r = 0.71, p < 0.0001). The early diastolic relaxation velocity by tissue Doppler and longitudinal relaxation rate for the lateral mitral annulus displacement were positively associated (p = 0.007), as were the ratio between Doppler E/e' and CMR E/E' (p = 0.01). CMR-determined normalized peak E (NE) and deceleration time (DT) were able to predict diastolic dysfunction (areas under the curve [AUCs] = 0.70 and 0.72, respectively). In addition, the lateral E/E' ratio showed good utility in identifying diastolic dysfunction (AUC = 0.80). Overall, echocardiography and CMR interobserver and intraobserver agreements were excellent (intraclass correlation coefficient range 0.72 - 0.97). Conclusion: 3D modeling of standard cine CMR images was able to identify study subjects with reduced diastolic function and showed good reproducibility, suggesting a potential for a routine diastolic function assessment by CMR.


Resumo Fundamento: A ressonância magnética cardíaca necessita de um método simples e robusto para a avaliação da função diastólica que pode ser feito com sequências protocolares de rotina. Objetivo: Desenvolver e validar a avaliação volumétrica da função diastólica através de um modelo tridimensional (3D) com utilização de imagens de ressonância magnética cardíaca (RMC) e comparar os resultados obtidos com este modelo com os obtidos por ecocardiografia. Métodos: Os participantes do estudo assinaram um termo de consentimento e foram incluídos se tivessem sido submetidos no mesmo dia tanto à ecocardiografia quanto à cine RMC com precessão livre no estado estacionário (steady-state free precession, SSFP). Pontos-guia foram utilizados no anel mitral septal e lateral para definir a velocidade de estiramento no início da diástole (E'), enquanto curvas de volume-tempo do modelo 3D foram utilizadas para avaliar os parâmetros de enchimento diastólico. Foram determinadas a correlação entre a RMC 3D e a ecocardiografia, além da acurácia da RMC em classificar o grau de função diastólica. Resultados: Ao todo, 102 sujeitos foram incluídos no estudo. A razão E/A pela RMC esteve positivamente associada com a razão E/A obtida pela ecocardiografia (r = 0,71, p < 0,0001). Estiveram positivamente associadas a velocidade de relaxamento diastólico inicial ao Doppler tecidual e a velocidade de relaxamento longitudinal de deslocamento do anel mitral lateral (p = 0,007), bem como a razão entre E/e' por Doppler e E/E' pela RMC (p = 0,01). A velocidade normalizada de pico de enchimento (EM) determinada pela RMC e o tempo de desaceleração (TD) foram capazes de predizer a disfunção diastólica (áreas sob a curva [AUCs] = 0,70 e 0,72, respectivamente). Além disso, a razão E/E' lateral mostrou boa utilidade para a identificação da disfunção diastólica (AUC = 0,80). No geral, a ecocardiografia e a RMC apresentaram excelente concordância interobservador e intraobservador (coeficiente de correlação intraclasse 0,72 - 0,97). Conclusão: Uma modelagem 3D de imagens padrões de cine RMC foi capaz de identificar os indivíduos do estudo com função diastólica reduzida e mostrou uma boa reprodutibilidade, sugerindo ter potencial na avaliação rotineira da função diastólica por RMC.


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Volume Sistólico/fisiologia , Aterosclerose/diagnóstico por imagem , Imageamento por Ressonância Magnética , Ecocardiografia , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Imageamento Tridimensional , Diástole/fisiologia , Aterosclerose/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA