Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Clin Res Cardiol ; 105(1): 17-28, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26123829

RESUMO

BACKGROUND: Heart failure (HF) epidemic has increased need for accurate diastolic dysfunction (DD) quantitation. Cardiac MRI can elucidate left atrial (LA) phasic function, and accurately quantify its conduit contribution to left ventricular (LV) filling, but has limited availability. We hypothesized that the percentage of LV stroke volume due to atrial conduit volume (LACV), as assessed using 3D-echocardiography, can differentiate among progressive degrees of DD in HF patients. METHODS AND RESULTS: Sixty-three subjects (66 ± 12 years) with DD and ejection fraction (EF) ranging 14-62% underwent full-volume 3D-echocardiography. Simultaneous LA and LV volume curves as function of time (t) were calculated, with LACV as LACV(t) = [LV(t) - LV minimum] - [LA maximum LA(t)], expressed as % of stroke volume. Patients were assigned to four (0-3, from none to severe) DD grades, according to classical Doppler parameters. In this population DD is linked to LACV, with progressively higher percentages of conduit contribution to stroke volume associated with higher degrees of DD (p = 0.0007). Patients were then dichotomized into no-mild (n = 26) or severe (n = 37) DD groups. Apart from atrial volume, larger (p < 0.02) in severe DD group, no differences between groups were found for LV diastolic and stroke volume, EF, mass and flow propagation velocity. However, a significant difference was found for LACV expressed as % of LV stroke volume (29 ± 15 vs. 43 ± 23%, p = 0.016). CONCLUSIONS: Our study confirms that LACV contribution to stroke volume increases along with worsening DD, as assessed in the context of (near) constant-volume four-chamber heart physiology. Thus, LACV can serve as new parameter for DD grading severity in HF patients.


Assuntos
Função do Átrio Esquerdo/fisiologia , Diástole/fisiologia , Insuficiência Cardíaca/fisiopatologia , Volume Sistólico/fisiologia , Idoso , Ecocardiografia Doppler , Ecocardiografia Tridimensional , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Índice de Gravidade de Doença
2.
World J Cardiol ; 7(8): 490-8, 2015 Aug 26.
Artigo em Inglês | MEDLINE | ID: mdl-26322189

RESUMO

AIM: To evaluate the safety and efficacy of the permanent high interventricular septal pacing in a long term follow up, as alternative to right ventricular apical pacing. METHODS: We retrospectively evaluated: (1) 244 patients (74 ± 8 years; 169 men, 75 women) implanted with a single (132 pts) or dual chamber (112 pts) pacemaker (PM) with ventricular screw-in lead placed at the right ventricular high septal parahisian site (SEPTAL pacing); (2) 22 patients with permanent pacemaker and low percentage of pacing (< 20%) (NO pacing); (3) 33 patients with high percentage (> 80%) right ventricular apical pacing (RVA). All patients had a narrow spontaneous QRS (101 ± 14 ms). We evaluated New York Heart Association (NYHA) class, quality of life (QoL), 6 min walking test (6MWT) and left ventricular function (end-diastolic volume, LV-EDV; end-systolic volume, LV-ESV; ejection fraction, LV-EF) with 2D-echocardiography. RESULTS: Pacing parameters were stable during follow up (21 mo/patient). In SEPTAL pacing group we observed an improvement in NYHA class, QoL score and 6MWT. While LV-EDV didn't significantly increase (104 ± 40 mL vs 100 ± 37 mL; P = 0.35), LV-ESV slightly increased (55 ± 31 mL vs 49 ± 27 mL; P = 0.05) and LV-EF slightly decreased (49% ± 11% vs 53% ± 11%; P = 0.001) but never falling < 45%. In the RVA pacing control group we observed a worsening of NYHA class and an important reduction of LV-EF (from 56% ± 6% to 43% ± 9%, P < 0.0001). CONCLUSION: Right ventricular permanent high septal pacing is safe and effective in a long term follow up evaluation; it could be a good alternative to the conventional RVA pacing in order to avoid its deleterious effects.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA