Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Nat Commun ; 13(1): 4193, 2022 07 20.
Artigo em Inglês | MEDLINE | ID: mdl-35858962

RESUMO

Here we show how major rivers can efficiently connect to the deep-sea, by analysing the longest runout sediment flows (of any type) yet measured in action on Earth. These seafloor turbidity currents originated from the Congo River-mouth, with one flow travelling >1,130 km whilst accelerating from 5.2 to 8.0 m/s. In one year, these turbidity currents eroded 1,338-2,675 [>535-1,070] Mt of sediment from one submarine canyon, equivalent to 19-37 [>7-15] % of annual suspended sediment flux from present-day rivers. It was known earthquakes trigger canyon-flushing flows. We show river-floods also generate canyon-flushing flows, primed by rapid sediment-accumulation at the river-mouth, and sometimes triggered by spring tides weeks to months post-flood. It is demonstrated that strongly erosional turbidity currents self-accelerate, thereby travelling much further, validating a long-proposed theory. These observations explain highly-efficient organic carbon transfer, and have important implications for hazards to seabed cables, or deep-sea impacts of terrestrial climate change.


Assuntos
Sedimentos Geológicos , Rios , Carbono , Monitoramento Ambiental , Inundações , Estações do Ano
2.
J Acoust Soc Am ; 122(6): 3495-506, 2007 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-18247758

RESUMO

High-rate acoustic communication experiments were conducted in a dynamic estuarine environment. Two current profilers deployed in a shipping lane were interfaced with acoustic modems, which modulated and transmitted the sensor readings every 200 s over a period of four days. QPSK modulation was employed at a raw data rate of 8 kbits on a 12-kHz carrier. Two 16-element hydrophone arrays, one horizontal and one vertical, were deployed near the shore. A multichannel decision-feedback equalizer was used to demodulate the modem signals received on both arrays. Long-term statistical analysis reveals the effects of the tidal cycle, subsea unit location, attenuation by the wake of passing vessels, and high levels of ship-generated noise on the fidelity of the communication links. The use of receiver arrays enables vast improvement in the overall reliability of data delivery compared with a single-receiver system, with performance depending strongly on array orientation. The vertical array offers the best performance overall, although the horizontal array proves more robust against shipping noise. Spatial coherence estimates, variation of array aperture, and inspection of array angular responses point to adaptive beamforming and coherent combining as the chief mechanisms of array gain.


Assuntos
Acústica , Comunicação , Ruído dos Transportes , Oceanografia/métodos , Navios , Acústica/instrumentação , Efeito Doppler , Meio Ambiente , Desenho de Equipamento , Modelos Teóricos , Modems , Oceanografia/instrumentação , Reprodutibilidade dos Testes , Água do Mar , Processamento de Sinais Assistido por Computador , Espectrografia do Som , Temperatura , Fatores de Tempo , Movimentos da Água
3.
IEEE Trans Biomed Circuits Syst ; 11(4): 849-857, 2017 08.
Artigo em Inglês | MEDLINE | ID: mdl-28715339

RESUMO

OBJECTIVE: In this paper, we present the design of low-cost medical ultrasound scanners aimed at the detection of maternal mortality risk factors in developing countries. METHOD: Modern ultrasound scanners typically employ a high element count transducer array with multichannel transmit and receive electronics. To minimize hardware costs, we employ a single piezoelectric element, mechanically swept across the target scene, and a highly cost-engineered single channel acquisition circuit. Given this constraint, we compare the achievable image quality of a monostatic fixed focus scanner (MFFS) with a monostatic synthetic aperture scanner (MSAS) using postfocusing. Quantitative analysis of image quality was carried out using simulation and phantom experiments, which were used to compare a proof-of-concept MSAS prototype with an MFFS device currently available on the market. Finally, in vivo experiments were performed to validate the MSAS prototype in obstetric imaging. RESULTS: Simulations show that the achievable lateral resolution of the MSAS approach is superior at all ranges compared to the fixed focus approach. Phantom experiments verify the improved resolution of the MSAS prototype but reveal a lower signal to noise ratio. In vivo experiments show promising results using the MSAS for clinical diagnostics in prenatal care. CONCLUSION: The proposed MSAS achieves superior resolution but lower SNR compared to an MFFS approach, principally due to lower acoustic energy emitted. SIGNIFICANCE: The production costs of the proposed MSAS could be an order of magnitude lower than any other ultrasound system on the market today, bringing affordable obstetric imaging a step closer for developing countries.


Assuntos
Obstetrícia/instrumentação , Ultrassonografia/instrumentação , Desenho de Equipamento , Feminino , Humanos , Mortalidade Materna , Imagens de Fantasmas , Gravidez , Fatores de Risco , Razão Sinal-Ruído , Transdutores
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA