Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
J Vasc Interv Radiol ; 34(4): 544-555.e11, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36379286

RESUMO

PURPOSE: To update normative data on fluoroscopy dose indices in the United States for the first time since the Radiation Doses in Interventional Radiology study in the late 1990s. MATERIALS AND METHODS: The Dose Index Registry-Fluoroscopy pilot study collected data from March 2018 through December 2019, with 50 fluoroscopes from 10 sites submitting data. Primary radiation dose indices including fluoroscopy time (FT), cumulative air kerma (Ka,r), and kerma area product (PKA) were collected for interventional radiology fluoroscopically guided interventional (FGI) procedures. Clinical facility procedure names were mapped to the American College of Radiology (ACR) common procedure lexicon. Distribution parameters including the 10th, 25th, 50th, 75th, 95th, and 99th percentiles were computed. RESULTS: Dose indices were collected for 70,377 FGI procedures, with 50,501 ultimately eligible for analysis. Distribution parameters are reported for 100 ACR Common IDs. FT in minutes, Ka,r in mGy, and PKA in Gy-cm2 are reported in this study as (n; median) for select ACR Common IDs: inferior vena cava filter insertion (1,726; FT: 2.9; Ka,r: 55.8; PKA: 14.19); inferior vena cava filter removal (464; FT: 5.7; Ka,r: 178.6; PKA: 34.73); nephrostomy placement (2,037; FT: 4.1; Ka,r: 39.2; PKA: 6.61); percutaneous biliary drainage (952; FT: 12.4; Ka,r: 160.5; PKA: 21.32); gastrostomy placement (1,643; FT: 3.2; Ka,r: 29.1; PKA: 7.29); and transjugular intrahepatic portosystemic shunt placement (327; FT: 34.8; Ka,r: 813.0; PKA: 181.47). CONCLUSIONS: The ACR DIR-Fluoro pilot has provided state-of-the-practice statistics for radiation dose indices from IR FGI procedures. These data can be used to prioritize procedures for radiation optimization, as demonstrated in this work.


Assuntos
Radiografia Intervencionista , Radiologia Intervencionista , Humanos , Doses de Radiação , Projetos Piloto , Fluoroscopia , Radiologia Intervencionista/métodos , Sistema de Registros , Radiografia Intervencionista/efeitos adversos
2.
J Vasc Interv Radiol ; 34(4): 556-562.e3, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36031041

RESUMO

PURPOSE: To compare radiation dose index distributions for fluoroscopically guided interventions in interventional radiology from the American College of Radiology (ACR) Fluoroscopy Dose Index Registry (DIR-Fluoro) pilot to those from the Radiation Doses in Interventional Radiology (RAD-IR) study. MATERIALS AND METHODS: Individual and grouped ACR Common identification numbers (procedure types) from the DIR-Fluoro pilot were matched to procedure types in the RAD-IR study. Fifteen comparisons were made. Distribution parameters, including the 10th, 25th, 50th, 75th, and 95th percentiles, were compared for fluoroscopy time (FT), cumulative air kerma (Ka,r), and kerma area product (PKA). Two derived indices were computed using median dose indices. The procedure-averaged reference air kerma rate (Ka,r¯) was computed as Ka,r / FT. The procedure-averaged x-ray field size at the reference point (Ar) was computed as PKA / (Ka,r × 1,000). RESULTS: The median FT was equally likely to be higher or lower in the DIR-Fluoro pilot as it was in the RAD-IR study, whereas the maximum FT was almost twice as likely to be higher in the DIR-Fluoro pilot than it was in the RAD-IR study. The median Ka,r was lower in the DIR-Fluoro pilot for all procedures, as was median PKA. The maximum Ka,r and PKA were more often higher in the DIR-Fluoro pilot than in the RAD-IR study. Ka,r¯ followed the same pattern as Ka,r, whereas Ar was often greater in DIR-Fluoro. CONCLUSIONS: The median dose indices have decreased since the RAD-IR study. The typical Ka,r rates are lower, a result of the use of lower default dose rates. However, opportunities for quality improvement exist, including renewed focus on tight collimation of the imaging field of view.


Assuntos
Radiografia Intervencionista , Radiologia Intervencionista , Humanos , Radiologia Intervencionista/métodos , Doses de Radiação , Fluoroscopia , Radiografia Intervencionista/efeitos adversos , Sistema de Registros
3.
J Vasc Interv Radiol ; 31(10): 1545-1550.e1, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32861568

RESUMO

PURPOSE: To characterize the accuracy and consistency of fluoroscope dose index reporting and report rates of occupational radiation safety hardware availability and use, trainee participation in procedures, and optional hardware availability at pilot sites for the American College of Radiology (ACR) Fluoroscopy Dose Index Registry (DIR). MATERIALS AND METHODS: Nine institutions participated in the registry pilot, providing fluoroscopic technical and clinical practice data from 38 angiographic C-arm-type fluoroscopes. These data included measurements of the procedure table and mattress transmission factors and accuracy measurements of the reference-point air kerma (Ka,r) and air kerma-area product (PKA). The accuracy of the radiation dose indices were analyzed for variation over time by 1-way analysis of variance (ANOVA). Sites also self-reported information on availability and use of radiation safety hardware, hardware configuration of fluoroscopes, and trainee participation in procedures. RESULTS: All Ka,r and PKA measurements were within the ±35% regulatory limit on accuracy. The mean absolute difference between correction factors for a given system in fluoroscopic and acquisition mode was 0.03 (95% confidence interval, 0.03-0.03). For the 28 fluoroscopic imaging planes that provided data for 3 time points, ANOVA yielded an F value of 0.134 with an F-critical value of 3.109 (P = .875). CONCLUSIONS: This publication provides the technical and clinical framework pertaining to the ACR Fluoroscopy DIR pilot and offers necessary context for future analysis of the clinical procedure radiation-dose data collected.


Assuntos
Exposição Ocupacional , Doses de Radiação , Exposição à Radiação , Monitoramento de Radiação , Radiografia Intervencionista , Fluoroscopia , Humanos , Exposição Ocupacional/efeitos adversos , Saúde Ocupacional , Projetos Piloto , Exposição à Radiação/efeitos adversos , Radiografia Intervencionista/efeitos adversos , Sistema de Registros , Medição de Risco , Fatores de Risco , Espalhamento de Radiação , Estados Unidos
5.
Radiat Res ; 186(4): 385-395, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27643875

RESUMO

The goal of this study was to determine if depletion of glutathione (GSH) and inhibition of thioredoxin (Trx) reductase (TrxR) activity could enhance radiation responses in human breast cancer stem cells by a mechanism involving thiol-dependent oxidative stress. The following were used to inhibit GSH and Trx metabolism: buthionine sulfoximine (BSO), a GSH synthesis inhibitor; sulfasalazine (SSZ), an inhibitor of xc- cysteine/glutamate antiporter; auranofin (Au), a thioredoxin reductase inhibitor; or 2-AAPA, a GSH-reductase inhibitor. Clonogenic survival, Matrigel assays, flow cytometry cancer stem cell assays (CD44+CD24-ESA+ or ALDH1) and human tumor xenograft models were used to determine the antitumor activity of drug and radiation combinations. Combined inhibition of GSH and Trx metabolism enhanced cancer cell clonogenic killing and radiation responses in human breast and pancreatic cancer cells via a mechanism that could be inhibited by N-acetylcysteine (NAC). Au, BSO and radiation also significantly decreased breast cancer cell migration and invasion in a thiol-dependent manner that could be inhibited by NAC. In addition, pretreating cells with Au sensitized breast cancer stem cell populations to radiation in vitro as determined by CD44+CD24-ESA+ or ALDH1. Combined administration of Au and BSO, given prior to irradiation, significantly increased the survival of mice with human breast cancer xenografts, and decreased the number of ALDH1+ cancer stem cells. These results indicate that combined inhibition of GSH- and Trx-dependent thiol metabolism using pharmacologically relevant agents can enhance responses of human breast cancer stem cells to radiation both in vitro and in vivo.


Assuntos
Neoplasias da Mama/patologia , Glutationa/metabolismo , Células-Tronco Neoplásicas/efeitos dos fármacos , Células-Tronco Neoplásicas/efeitos da radiação , Radiossensibilizantes/farmacologia , Tiorredoxinas/metabolismo , Acetilcisteína/análogos & derivados , Acetilcisteína/farmacologia , Animais , Auranofina/farmacologia , Butionina Sulfoximina/farmacologia , Linhagem Celular Tumoral , Movimento Celular/efeitos dos fármacos , Movimento Celular/efeitos da radiação , Sobrevivência Celular/efeitos dos fármacos , Sobrevivência Celular/efeitos da radiação , Transformação Celular Neoplásica , Dano ao DNA , Interações Medicamentosas , Feminino , Glutationa/biossíntese , Humanos , Camundongos , Invasividade Neoplásica , Células-Tronco Neoplásicas/metabolismo , Células-Tronco Neoplásicas/patologia , Sulfassalazina/farmacologia , Análise de Sobrevida , Tiocarbamatos/farmacologia , Tiorredoxina Dissulfeto Redutase/antagonistas & inibidores
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA