Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 41
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Radiology ; 302(2): 419-424, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34783593

RESUMO

Background There are multiple tools available to visualize the retinal and choroidal vasculature of the posterior globe. However, there are currently no reliable in vivo imaging techniques that can visualize the entire retrobulbar course of the retinal and ciliary vessels. Purpose To identify and characterize the central retinal artery (CRA) using cone-beam CT (CBCT) images obtained as part of diagnostic cerebral angiography. Materials and Methods In this retrospective study, patients with catheter DSA performed between October 2019 and October 2020 were included if CBCT angiography included the orbit in the field of view. The CBCT angiography data sets were postprocessed with a small field-of-view volume centered in the posterior globe to a maximum resolution of 0.2 mm. The following were evaluated: CRA origin, CRA course, CRA point of penetration into the optic nerve sheath, bifurcation of the CRA at the papilla, visualization of anatomic variants, and visualization of the central retinal vein. Descriptive statistical analysis was performed. Results Twenty-one patients with 24 visualized orbits were included in the analysis (mean age, 55 years ± 15; 14 women). Indications for angiography were as follows: diagnostic angiography (n = 8), aneurysm treatment (n = 6), or other (n = 7). The CRA was identified in all orbits; the origin, course, point of penetration of the CRA into the optic nerve sheath, and termination in the papilla were visualized in all orbits. The average length of the intraneural segment was 10.6 mm (range, 7-18 mm). The central retinal vein was identified in six of 24 orbits. Conclusion Cone-beam CT, performed during diagnostic angiography, consistently demonstrated the in vivo central retinal artery, demonstrating excellent potential for multiple diagnostic and therapeutic applications. © RSNA, 2021 Online supplemental material is available for this article.


Assuntos
Angiografia Cerebral , Angiografia por Tomografia Computadorizada , Tomografia Computadorizada de Feixe Cônico , Artéria Retiniana/diagnóstico por imagem , Angiografia Digital , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
2.
Cerebrovasc Dis ; 50(4): 464-471, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33971661

RESUMO

BACKGROUND: Comaneci (Rapid Medical) is a compliant, adjustable mesh that provides temporary scaffolding during coiling of wide-necked intracranial aneurysms (WNAs) that preserves antegrade flow. We report our early multi-institutional experience with the Comaneci device in the USA. METHOD: We reviewed all patients with WNAs that were treated using the Comaneci device for coil remodeling of ruptured and unruptured aneurysms at 4 institutions between July 2019 and May 2020. Clinical characteristics, angiographic variables, and endovascular results were assessed. RESULTS: A total of 26 patients were included (18 women). The mean age was 62.7 years (range 44-81). Fifteen patients presented with ruptured aneurysms and 11 with unruptured aneurysms. The mean aneurysm neck width was 3.91 mm (range 1.9-6.5) with a mean dome-to-neck ratio of 1.57 (range 0.59-3.39). The mean maximum width was 5.80 mm (range 3.0-9.9) and the mean maximum height was 5.61 mm (range 2.0-11.8). Successful aneurysm occlusion was achieved in 25 of 26 patients. Complete occlusion was achieved in 16 patients, near-complete occlusion was observed in 9 patients, and 1 patient demonstrated residual filling. The mean time of device exposure was 24 min (range 8-76). No vasospasm was observed at the device location. Clot formation on the device was noted in 2 separate cases, but there were no clinical sequelae. There was 1 intraprocedural complication in a case that involved the simultaneous use of 2 Comaneci devices. CONCLUSIONS: Our initial experience shows that the Comaneci device is a promising and reliable tool that can safely support coil remodeling of WNAs.


Assuntos
Embolização Terapêutica/instrumentação , Aneurisma Intracraniano/terapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Aprovação de Equipamentos , Embolização Terapêutica/efeitos adversos , Desenho de Equipamento , Feminino , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento , Estados Unidos , United States Food and Drug Administration
3.
Neurosurg Clin N Am ; 35(3): 273-286, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38782520

RESUMO

Comprehensive understanding of venous anatomy is a key factor in the approach to a multitude of conditions. Moreover, the venous system has become the center of attention as a new frontier for treatment of diseases such as idiopathic intracranial hypertension (IIH), arteriovenous malformation (AVM), pulsatile tinnitus, hydrocephalus, and cerebrospinal fluid (CSF) venous fistulas. Its knowledge is ever more an essential requirement of the modern brain physician. In this article, the authors explore the descriptive and functional anatomy of the venous system of the CNS in 5 subsections: embryology, dural sinuses, cortical veins, deep veins, and spinal veins.


Assuntos
Veias Cerebrais , Humanos , Veias Cerebrais/anatomia & histologia , Cavidades Cranianas/anatomia & histologia , Sistema Nervoso Central/anatomia & histologia , Sistema Nervoso Central/irrigação sanguínea
4.
Artigo em Inglês | MEDLINE | ID: mdl-38663989

RESUMO

BACKGROUND AND PURPOSE: Successful post-flow-diverter endoluminal reconstruction is widely believed to require endothelial overgrowth of the aneurysmal inflow zone. However, endothelialization/neointimal overgrowth is a complex process, over which we currently have very limited influence. Less emphasized is vascular remodeling of the target arterial segment, the dynamic response of the vessel to flow-diverter implantation. This process is distinct from flow modifications in covered branches. It appears that basic angiographic methods allow simple and useful observations. The purpose of this article was to quantitatively evaluate observable postimplantation changes in target vessels following deployment of Pipeline endoluminal constructs. MATERIALS AND METHODS: One hundred consecutive adults with unruptured, previously untreated, nondissecting aneurysms treated with the Pipeline Embolization Device with Shield Technology and the availability of follow-up conventional angiography were studied with 2D DSA imaging. Target vessel size; Pipeline Embolization Device diameter; endothelial thickness; and various demographic, antiplatelet, and device-related parameters were recorded and analyzed. RESULTS: The thickness of neointimal overgrowth (mean, 0.3 [SD, 0.1] mm; range, 0.1-0.7 mm) is inversely correlated with age and is independent of vessel size, smoking status, sex, and degree of platelet inhibition. The decrease in lumen diameter caused by neointimal overgrowth, however, appears counteracted by outward remodeling (dilation) of the target arterial segment. This leads to an increase in the diameter with a corresponding decrease in length (foreshortening) of the implanted Pipeline Embolization Device. This physiologic remodeling process affects optimally implanted devices and is not a consequence of stretching, device migration, vasospasm, and so forth. A direct, linear, statistically significant relationship exists between the degree of observed outward remodeling and the diameter of the implanted Pipeline Embolization Device relative to the target vessel. Overall, remodeled arterial diameters were reduced by 15% (SD, 10%) relative to baseline and followed a normal distribution. Clinically relevant stenosis was not observed. CONCLUSIONS: Vessel healing involves both outward remodeling and neointimal overgrowth. Judicial oversizing could be useful in specific settings to counter the reduction in lumen diameter due to postimplant neointimal overgrowth; however, this overszing needs to be balanced against the decrease in metal coverage accompanying the use of oversized devices. Similar analysis for other devices is essential.

5.
World Neurosurg ; 182: e245-e252, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38006939

RESUMO

OBJECTIVE: To examine the usefulness of carotid web (CW), carotid bifurcation and their combined angioarchitectural measurements in assessing stroke risk. METHODS: Anatomic data on the internal carotid artery (ICA), common carotid artery (CCA), and the CW were gathered as part of a retrospective study from symptomatic (stroke) and asymptomatic (nonstroke) patients with CW. We built a model of stroke risk using principal-component analysis, Firth regression trained with 5-fold cross-validation, and heuristic binary cutoffs based on the Minimal Description Length principle. RESULTS: The study included 22 patients, with a mean age of 55.9 ± 12.8 years; 72.9% were female. Eleven patients experienced an ischemic stroke. The first 2 principal components distinguished between patients with stroke and patients without stroke. The model showed that ICA-pouch tip angle (P = 0.036), CCA-pouch tip angle (P = 0.036), ICA web-pouch angle (P = 0.036), and CCA web-pouch angle (P = 0.036) are the most important features associated with stroke risk. Conversely, CCA and ICA anatomy (diameter and angle) were not found to be risk factors. CONCLUSIONS: This pilot study shows that using data from computed tomography angiography, carotid bifurcation, and CW angioarchitecture may be used to assess stroke risk, allowing physicians to tailor care for each patient according to risk stratification.


Assuntos
Estenose das Carótidas , Acidente Vascular Cerebral , Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Masculino , Artéria Carótida Interna/diagnóstico por imagem , Estudos Retrospectivos , Projetos Piloto , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/complicações , Artéria Carótida Primitiva , Medição de Risco , Estenose das Carótidas/complicações
6.
Artigo em Inglês | MEDLINE | ID: mdl-38717168

RESUMO

BACKGROUND AND OBJECTIVES: Robotics are becoming increasingly widespread within various neurosurgical subspecialties, but data pertaining to their feasibility in vascular neurosurgery are limited. We present our novel attempt to evaluate the learning curve of a robotic platform for microvascular anastomoses. METHODS: One hundred and sixty one sutures were performed and assessed. Fourteen anastomoses (10 robotic [MUSA-2 Microsurgical system; Microsure] and 4 hand-sewn) were performed by the senior author on 1.5-mm caliber tubes and recorded with the Kinevo 900 (Zeiss) operative microscope. We separately compared interrupted sutures (from needle insertion until third knot) and running sutures (from needle insertion until loop pull-down). Average suture timing across all groups was compared using an unpaired Student's t test. Exponential smoothing (α = 0.2) was then applied to the robotic data sets for validation and a second set of t tests were performed. RESULTS: We compared 107 robotic sutures with 54 hand-sewn sutures. There was a significant difference between the average time/stitch for the robotic running sutures (n = 55) and the hand-sewn running sutures (n = 31) (31.2 seconds vs 48.3 seconds, respectively; P-value = .00052). Exponential smoothing (α = 0.2) reinforced these results (37.6 seconds vs 48.3 seconds; P-value = .014625). Average robotic running times surpassed hand-sewn by the second anastomosis (38.8 seconds vs 48.3 seconds) and continued to steadily decrease with subsequent stitches. The average of the robotic interrupted sutures (n = 52) was significantly longer than the hand-sewn (n = 23) (171.3 seconds vs 70 seconds; P = .000024). Exponential smoothing (α = 0.2) yielded similar results (196.7 seconds vs 70 seconds; P = .00001). However, average robotic interrupted times significantly decreased from the first to the final anastomosis (286 seconds vs 105.2 seconds; P = .003674). CONCLUSION: Our results indicate the learning curve for robotic microanastomoses is short and encouraging. The use of robotics warrants further study for potential use in cerebrovascular bypass procedures.

7.
J Neurointerv Surg ; 15(5): 452-460, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-35803732

RESUMO

Meaningful contributions to neurointerventional practice may be possible by considering the dynamic aspects of angiography in addition to fixed morphologic information. The functional approach to venous anatomy requires integration of the traditional static anatomic features of the system-deep, superficial, posterior fossa, medullary veins, venous sinuses, and outflow routes into an overall appreciation of how a classic model of drainage is altered, embryologically, or pathologically, depending on patterns of flow-visualization made possible by angiography. In this review, emphasis is placed on balance between alternative venous networks and their redundancy, and the problems which arise when these systems are lacking. The role of veins in major neurovascular diseases, such as dural arteriovenous fistulae, arteriovenous malformations, pulsatile tinnitus, and intracranial hypertension, is highlighted, and deficiencies in knowledge emphasized.


Assuntos
Malformações Arteriovenosas , Malformações Vasculares do Sistema Nervoso Central , Veias Cerebrais , Humanos , Angiografia Cerebral , Veias Cerebrais/diagnóstico por imagem , Malformações Vasculares do Sistema Nervoso Central/diagnóstico por imagem , Drenagem
8.
Interv Neuroradiol ; : 15910199231158912, 2023 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-36843545

RESUMO

There are multiple treatment alternatives for cavernous dAVFs, with transvenous routes being most common. Among these routes, occluded inferior petrosal sinus is well-described, and, apart from being imaginative and elegant, it is also safe and effective. Herein we describe the application of this method to reach the fistulous pouch of a cavernous dAVF via an occluded superior petrosal sinus.

9.
J Neurointerv Surg ; 2023 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-37673678

RESUMO

Understanding normal spinal arterial and venous anatomy, and spinal vascular disease, is impossible without flow-based methods. Development of practical spinal angiography led to site-specific categorization of spinal vascular conditions, defined by the 'seat of disease' in relation to the cord and its covers. This enabled identification of targets for highly successful surgical and endovascular treatments, and guided interpretation of later cross-sectional imaging.Spinal dural and epidural arteriovenous fistulas represent the most common types of spinal shunts. Although etiology is debated, anatomy provides excellent pathophysiologic correlation. A spectrum of fistulas, from foramen magnum to the sacrum, is now well-characterized.Most recently, use of cone beam CT angiography has yielded new insights into normal and pathologic anatomy, including venous outflow. It provides unrivaled visualization of the fistula and its relationship with spinal cord vessels, and is the first practical method to study normal and pathologic spinal veins in vivo-with multiple implications for both safety and efficacy of treatments. We advocate consistent use of cone beam CT imaging in modern spinal fistula evaluation.The role of open surgery is likely to remain undiminished, with increasing availability and use of hybrid operating rooms for practical intraoperative angiography enhancing safety and efficacy of complex surgery.

10.
J Neurointerv Surg ; 2023 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-37316194

RESUMO

BACKGROUND: Current imaging algorithms for post-device evaluation are limited by either poor representation of the device or poor delineation of the treated vessel. Combining the high-resolution images from a traditional three-dimensional digital subtraction angiography (3D-DSA) protocol with the longer cone-beam computed tomography (CBCT) protocol may provide simultaneous visualization of both the device and the vessel content in a single volume, improving the accuracy and detail of the assessment. We aim here to review our use of this technique which we termed "SuperDyna". METHODS: In this retrospective study, patients who underwent an endovascular procedure between February 2022 and January 2023 were identified. We analyzed patients who had both non-contrast CBCT and 3D-DSA post-treatment and collected information on pre-/post-blood urea nitrogen, creatinine, radiation dose, and the intervention type. RESULTS: In 1 year, SuperDyna was performed in 52 (of 1935, 2.6%) patients, of which 72% were women, median age 60 years. The most common reason for the addition of the SuperDyna was for post-flow diversion assessment (n=39). Renal function tests showed no changes. The average total procedure radiation dose was 2.8 Gy, with 4% dose and ~20 mL of contrast attributed to the additional 3D-DSA needed to generate the SuperDyna. CONCLUSIONS: The SuperDyna is a fusion imaging method that combines high-resolution CBCT and contrasted 3D-DSA to evaluate intracranial vasculature post-treatment. It allows for more comprehensive evaluation of the device position and apposition, aiding in treatment planning and patient education.

11.
Interv Neuroradiol ; : 15910199231165613, 2023 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-37032452

RESUMO

The persistent carotid-vertebrobasilar anastomoses are arterial communications between the anterior and posterior circulations due to the persistence of embryological connections. We here present an extremely rare instance of a transclival persistent carotid-vertebrobasilar anastomosis in a 10-month-old infant, which does not fit into any of the traditionally described categories, such as the trigeminal artery, hypoglossal artery, or proatlantal artery.

12.
J Neurointerv Surg ; 2023 Oct 24.
Artigo em Inglês | MEDLINE | ID: mdl-37875341

RESUMO

The superior hypophyseal arteries (SHAs) are well known in anatomical and surgical literature, with a well-established role in supply of the anterior hypophysis and superjacent optic apparatus. However, due to small size and overlap with other vessels, in vivo imaging by any modality has been essentially non-existent. Advances in high resolution cone beam CT angiography (CBCTA) now enables this deficiency to be addressed. This paper presents, to the best of our knowledge, the first comprehensive in vivo imaging evaluation of the SHAs. METHODS: Twenty-five CBCTA studies of common or internal carotid arteries were obtained for a variety of clinical reasons. Dedicated secondary reconstructions of the siphon were performed, recording the presence, number, and supply territory of SHAs. A spectrum approach, emphasizing balance with adjacent territories (inferior hypophyseal, ophthalmic, posterior and communicating region arteries) was investigated. RESULTS: The SHAs were present in all cases. Supply of the anterior pituitary was nearly universal (96%) and almost half (44%) originated from the 'cave' region, in excellent agreement with surgical literature. Optic apparatus supply was more difficult to adjudicate, but appeared present in most cases. The relationship with superior hypophyseal aneurysms was consistent. Patency following flow diverter placement was typical, despite a presumably rich collateral network. Embryologic implications with respect to the ophthalmic artery and infraoptic course of the anterior cerebral artery are intriguing. CONCLUSIONS: SHAs are consistently seen with CBCTA, allowing for correlation with existing anatomical and surgical literature, laying the groundwork for future in vivo investigation.

13.
J Neurointerv Surg ; 15(6): 600-607, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35835462

RESUMO

The aim of this review is to describe the acquisition and reformatting of state of the art high resolution cone beam CT (HR-CBCT) and demonstrate its role in multiple neurovascular conditions as a tool to improve the understanding of disease and guide therapeutic decisions. First, we will review the basic principle of CBCT acquisition, followed by the injection protocols and the reformatting paradigms. Next, multiple applications in different pathological conditions such as aneurysms, arteriovenous malformations, dural arteriovenous fistulas, and stroke will be described. HR-CBCT angiography, widely available, is uniquely useful in certain clinical scenarios to improve the understanding of disease and guide therapeutic decisions. It rapidly is becoming an essential tool for the contemporary neurointerventionalist.AChoAho.


Assuntos
Malformações Arteriovenosas , Malformações Vasculares do Sistema Nervoso Central , Humanos , Angiografia por Tomografia Computadorizada , Angiografia , Tomografia Computadorizada de Feixe Cônico/métodos , Malformações Vasculares do Sistema Nervoso Central/terapia
14.
J Neurointerv Surg ; 15(3): 248-254, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35292570

RESUMO

BACKGROUND: The pipeline embolization device (PED; Medtronic) has presented as a safe and efficacious treatment for small- and medium-sized intracranial aneurysms. Independently adjudicated long-term results of the device in treating these lesions are still indeterminate. We present 3-year results, with additional application of a flow diverter specific occlusion scale. METHODS: PREMIER (prospective study on embolization of intracranial aneurysms with pipeline embolization device) is a prospective, single-arm trial. Inclusion criteria were patients with unruptured wide-necked intracranial aneurysms ≤12 mm. Primary effectiveness (complete aneurysm occlusion) and safety (major neurologic event) endpoints were independently monitored and adjudicated. RESULTS: As per the protocol, of 141 patients treated with a PED, 25 (17.7%) required angiographic follow-up after the first year due to incomplete aneurysm occlusion. According to the Core Radiology Laboratory review, three (12%) of these patients progressed to complete occlusion, with an overall rate of complete aneurysm occlusion at 3 years of 83.3% (115/138). Further angiographic evaluation using the modified Cekirge-Saatci classification demonstrated that complete occlusion, neck residual, or aneurysm size reduction occurred in 97.1%. The overall combined safety endpoint at 3 years was 2.8% (4/141), with only one non-debilitating major event occurring after the first year. There was one case of aneurysm recurrence but no cases of delayed rupture in this series. CONCLUSIONS: The PED device presents as a safe and effective modality in treating small- and medium-sized intracranial aneurysms. The application of a flow diverter specific occlusion classification attested the long-term durability with higher rate of successful aneurysm occlusion and no documented aneurysm rupture. TRIAL REGISTRATION: NCT02186561.


Assuntos
Embolização Terapêutica , Aneurisma Intracraniano , Humanos , Angiografia Cerebral/métodos , Embolização Terapêutica/métodos , Seguimentos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Aneurisma Intracraniano/etiologia , Estudos Prospectivos , Estudos Retrospectivos , Resultado do Tratamento
15.
J Neurointerv Surg ; 14(2): 196-201, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33727412

RESUMO

BACKGROUND: The dural vasculature plays a key role in several important conditions, including dural fistulas and subdural collections. While in vivo investigations of intrinsic dural arterial angioarchitecture are rare, no angiographic studies of dural venous drainage exist to our knowledge. OBJECTIVE: To describe methods by which dural venous drainage might be visualized with current angiographic equipment and technique, and to correlate our results with existing ex vivo literature. METHODS: Digital subtraction angiography and 3D angiography (rotational and Dyna CT) of dural neurovasculature were acquired in the context of subdural hematoma embolization and normal dura. Protocols for visualization of dural venous drainage were established, and findings correlated with ex vivo studies. RESULTS: Meningeal arteries supply both the skull and dura. Normal dural enhancement is accentuated by the presence of hypervascular membranes. Intrinsic meningeal veins/sinuses parallel outer layer arteries with well-known tram-tracking appearance. Dura adjacent to main arterial trunks drains via skull base foramina into the pterygopalatine venous plexus, or via emissary veins into the temporalis venous plexus. Dura near the sinuses drains into venous pouches adjacent to the sinus, before emptying into the sinus proper-possibly the same pouches implicated in the angioarchitecture of dural fistulas. Finally, posterior temporoparietal convexity dura, situated in a watershed-like region between middle and posterior meningeal territories, frequently empties into diploic and emissary veins of the skull. Wide variation in balance is expected between these three routes. Drainage patterns appear to correlate with venous embryologic investigations of Padget and ex vivo studies in adults. CONCLUSIONS: Continued attention to dural venous drainage may prove useful in the diagnosis and management of dural-based vascular diseases.


Assuntos
Malformações Vasculares do Sistema Nervoso Central , Embolização Terapêutica , Adulto , Angiografia Digital , Malformações Vasculares do Sistema Nervoso Central/diagnóstico por imagem , Malformações Vasculares do Sistema Nervoso Central/terapia , Cavidades Cranianas , Dura-Máter/diagnóstico por imagem , Humanos , Artérias Meníngeas
16.
J Neurointerv Surg ; 13(12): 1190, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33685982

RESUMO

Cavernous sinus dural arteriovenous fistulas (CS-DAVF) can have an indolent course, with insidious onset, but still showing a high likelihood of spontaneous resolution.1 Nevertheless, symptoms in a subset of patients evolve more rapidly, with malignant signs on imaging, warranting intervention.2 We report on a patient in his 40s presenting with redness and proptosis of the right eye, intermittent blurred vision and diplopia. Once ophthalmological examination revealed increased intraocular pressure and imaging showed cortical venous congestion, the decision was made to obliterate a CS-DAVF involving the posteromedial right cavernous sinus.Multiple arteries including branches of the ascending pharyngeal artery, occipital artery and bilateral meningohypophyseal trunks supplied the fistula. Once transarterial embolization was deemed unsafe and both inferior petrosal sinuses did not grant access to the right cavernous sinus, a direct puncture to the cavernous sinus was performed to successfully coil the involved compartments.3-5 The aid of DynaCT imaging and needle guidance software is emphasized (video 1). neurintsurg;13/12/1190/V1F1V1Video 1.


Assuntos
Seio Cavernoso , Malformações Vasculares do Sistema Nervoso Central , Embolização Terapêutica , Seio Cavernoso/diagnóstico por imagem , Seio Cavernoso/cirurgia , Malformações Vasculares do Sistema Nervoso Central/diagnóstico por imagem , Malformações Vasculares do Sistema Nervoso Central/cirurgia , Cavidades Cranianas , Humanos , Punções
17.
J Neurointerv Surg ; 13(5): 471-477, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33632880

RESUMO

Adoption of middle meningeal artery embolization in the management of chronic subdural hematomas has led to a renewed interest in dural vascular anatomy. The readily identifiable major dural arteries and potential hazards associated with their embolization are well described. Less emphasized are several levels of intrinsic dural angioarchitecture, despite their more direct relationship to dural based diseases, such as subdural hematoma and dural fistula. Fortunately, microvascular aspects of dural anatomy, previously limited to ex vivo investigations, are becoming increasingly accessible to in vivo visualization, setting the stage for synthesis of the old and the new, and providing a rationale for the endovascular approach to subdural collections in particular. In contrast with traditional anatomical didactics, where descriptions advance from larger trunks to smaller pedicles, we present a strategic approach that proceeds from a fundamental understanding of the dural microvasculature and its relationship to larger vessels.


Assuntos
Embolização Terapêutica/métodos , Hematoma Subdural Crônico/diagnóstico por imagem , Hematoma Subdural Crônico/terapia , Artérias Meníngeas/anatomia & histologia , Artérias Meníngeas/diagnóstico por imagem , Dura-Máter/irrigação sanguínea , Dura-Máter/diagnóstico por imagem , Humanos , Neuroanatomia
18.
Oper Neurosurg (Hagerstown) ; 20(4): E284-E285, 2021 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-33517417

RESUMO

Initially developed for large and giant wide-necked aneurysms of the internal carotid artery, flow diverter devices are now used in almost every location safely and with effectiveness.1-5 This video demonstrates a unique case of a giant aneurysm of the right petrous internal carotid artery in a 20-yr-old patient. This is an extremely rare location, and most of patients are asymptomatic.3-6 Signs of compression of the seventh and eight cranial nerves can be present and even Horner syndrome and lower cranial nerves neuropathies. Nevertheless, rupture can lead to epistaxis and otorrhagia, and ultimately to hemorrhagic shock. The patient in the current report was otherwise healthy but presented with lightheadedness and dizziness for 10 d. The patient consented to the procedure. There was no history of major trauma or head and neck infection. A transradial endovascular flow diversion embolization of a giant aneurysm of the petrous internal carotid artery is herein demonstrated in a stepwise manner. A triaxial system was used to deploy 3 overlapping devices. Concepts of J-wire technique, multiple coverage,1 and the so-called weld technique are emphasized. The role of adjunctive coiling and main reasons for failure are also discussed.7,8 Brief cases of flow diversion embolization of aneurysms of different morphologies at different locations are used to highlight the importance of assessing vessel wall apposition and follow-up imaging.


Assuntos
Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Artéria Carótida Interna/diagnóstico por imagem , Artéria Carótida Interna/cirurgia , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Resultado do Tratamento
19.
Oper Neurosurg (Hagerstown) ; 20(5): 444-455, 2021 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-33475724

RESUMO

BACKGROUND: In the post-Carotid Occlusion Surgery Study (COSS) era, multiple reviews suggested subset groups of patients as potential candidates for superficial temporal artery to middle cerebral artery (STA-MCA) bypass. Among them are patients with recurrent strokes despite optimal medical therapy. There is a paucity of data on the outcome of bypass in these specific patients. OBJECTIVE: To examine the safety and efficacy of direct STA-MCA bypass in patients with nonmoyamoya, symptomatic steno-occlusive disease with impaired distal perfusion, who failed optimal medical management or endovascular treatment. METHODS: A retrospective review was performed to identify patients with cerebrovascular steno-occlusive disease who underwent bypass after symptomatic recurrent or rapidly progressive strokes, despite optimal conservative or endovascular treatment. RESULTS: A total of 8 patients (mean age 60 ± 6 yr) underwent direct or combined direct/indirect STA-MCA bypass between 2016 and 2019. All anastomoses were patent. One bypass carried slow flow. There were no procedure-related permanent deficits. One patient developed seizures which were controlled by medications. A total of 7 out of 8 patients were stable or improved clinically at last follow-up (mean 27.3 ± 13.8 mo) without recurrent strokes. One patient did not recover from their presenting stroke, experienced severe bilateral strokes 4 mo postoperatively, and subsequently expired. Modified Rankin Scale (mRS) improved in 6 patients (75%), remained stable in 1 patient (12.5%), and deteriorated in 1 (12.5%). Good long-term functional outcome was achieved in 5 patients (63%, mRS ≤ 2). CONCLUSION: Patients with symptomatic, hypoperfused steno-occlusive disease who fail optimal medical or endovascular treatment may benefit from cerebral revascularization. Direct or combined STA-MCA bypass was safe and provided favorable outcomes in this small series.


Assuntos
Revascularização Cerebral , Artérias Temporais , Idoso , Humanos , Pessoa de Meia-Idade , Artéria Cerebral Média/diagnóstico por imagem , Artéria Cerebral Média/cirurgia , Estudos Retrospectivos , Crânio , Artérias Temporais/cirurgia
20.
J Neurointerv Surg ; 12(8): 768-773, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32107286

RESUMO

Our perspective on anatomy frequently depends on how this anatomy is utilized in clinical practice, and by which methods knowledge is acquired. The thrombectomy revolution, of which the middle cerebral artery (MCA) is the most common target, is an example of a clinical paradigm shift with a unique perspective on cerebrovascular anatomy. This article reviews important features of MCA anatomy in the context of thrombectomy. Recognizing that variation, frequently explained by evolutionary concepts, is the rule when it comes to branching pattern, vessel morphology, territory, or collateral potential is key to successful thrombectomy strategy.


Assuntos
Artéria Cerebral Média/patologia , Sistema Nervoso/irrigação sanguínea , Sistema Nervoso/patologia , Trombectomia , Humanos , Artéria Cerebral Média/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA