Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 68
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Cytometry A ; 103(8): 631-645, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36966446

RESUMO

Characterization of target abundance on cells has broad translational applications. Among the approaches for assessing membrane target expression is quantification of the number of target-specific antibody (Ab) bound per cell (ABC). ABC determination on relevant cell subsets in complex and limited biological samples necessitates multidimensional immunophenotyping, for which the high-order multiparameter capabilities of mass cytometry provide considerable advantages. In the present study, we describe the implementation of CyTOF® for the concomitant quantification of membrane markers on diverse types of immune cells in human whole blood. Specifically, our protocol relies on establishing Bmax of Ab saturable binding on cells, then converted into ABC according to a metal's transmission efficiency and number of metal atoms per Ab. Using this method, we calculated ABC values for CD4 and CD8 within the expected range for circulating T cells and in concordance with the ABC obtained in the same samples by flow cytometry. Furthermore, we successfully conducted multiplex measurements of the ABC for CD28, CD16, CD32a, and CD64, on >15 immune cell subsets in human whole blood samples. We developed a high-dimensional data analysis workflow enabling semi-automated Bmax calculation in all examined cell subsets to facilitate ABC reporting across populations. In addition, we investigated impacts of the type of metal isotope and acquisition batch effect on the ABC evaluation with CyTOF®. In summary, our findings demonstrate mass cytometry is a valuable tool for concurrent quantitative analysis of multiple targets in specific and rare cell types, thus increasing the numbers of biomeasures obtained from a single sample.


Assuntos
Anticorpos , Linfócitos T , Humanos , Citometria de Fluxo/métodos , Imunofenotipagem
2.
J Proteome Res ; 21(10): 2331-2340, 2022 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-36049057

RESUMO

The fibronectin (FN) isoform including the extradomain B (EDB) segment (EDB + FN) is a promising tumor target and is highly expressed in some tumor types, such as breast, head, and neck cancer. To date, mostly immunohistochemistry (IHC) and Western blot have been used for the analysis of EDB + FN. However, complete quantitative measurements of EDB + FN expression in a tumor and circulation are important for the development of anti-EDB therapeutics. To this end, a method using protein enrichment followed by online antipeptide antibody enrichment coupled with a nanoflow LC-MS/MS was developed to quantify EDB + FN in human and cynomolgus plasma, patient-derived xenograft (PDX) tumors, and PDX formalin-fixed paraffin-embedded (FFPE) samples. Mouse plasma EDB + FN was analyzed using a protein immunoaffinity method followed by nanoflow LC-MS/MS. EDB + FN concentrations were 63.1 pmol/g in PDX breast cancer tumor and 49.6 pmol/g in PDX head and neck tumor. Mean plasma concentration was 1.1 nM (pmol/mL, 47.4 ng/mL) in normal healthy humans and 0.35 nM (15.1 ng/mL) in naive cynomolgus. The assay sensitivity was 0.018 nM based on calibration with recombinant human EDB + FN (rhEDB + FN).


Assuntos
Neoplasias da Mama , Fibronectinas , Animais , Neoplasias da Mama/patologia , Cromatografia Líquida , Modelos Animais de Doenças , Feminino , Fibronectinas/análise , Formaldeído , Xenoenxertos , Humanos , Camundongos , Inclusão em Parafina , Isoformas de Proteínas/metabolismo , Espectrometria de Massas em Tandem
3.
Gene Ther ; 29(10-11): 608-615, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-34737451

RESUMO

Duchenne muscular dystrophy (DMD) is a lethal, degenerative muscle disorder caused by mutations in the DMD gene, leading to severe reduction or absence of the protein dystrophin. Gene therapy strategies that aim to increase expression of a functional dystrophin protein (mini-dystrophin) are under investigation. The ability to accurately quantify dystrophin/mini-dystrophin is essential in assessing the level of gene transduction. We demonstrated the validation and application of a novel peptide immunoaffinity liquid chromatography-tandem mass spectrometry (IA-LC-MS/MS) assay. Data showed that dystrophin expression in Becker muscular dystrophy and DMD tissues, normalized against the mean of non-dystrophic control tissues (n = 20), was 4-84.5% (mean 32%, n = 20) and 0.4-24.1% (mean 5%, n = 20), respectively. In a DMD rat model, biceps femoris tissue from dystrophin-deficient rats treated with AAV9.hCK.Hopti-Dys3978.spA, an adeno-associated virus vector containing a mini-dystrophin transgene, showed a dose-dependent increase in mini-dystrophin expression at 6 months post-dose, exceeding wildtype dystrophin levels at high doses. Validation data showed that inter- and intra-assay precision were ≤20% (≤25% at the lower limit of quantification [LLOQ]) and inter- and intra-run relative error was within ±20% (±25% at LLOQ). IA-LC-MS/MS accurately quantifies dystrophin/mini-dystrophin in human and preclinical species with sufficient sensitivity for immediate application in preclinical/clinical trials.


Assuntos
Distrofina , Distrofia Muscular de Duchenne , Humanos , Ratos , Animais , Distrofina/genética , Distrofina/metabolismo , Distrofia Muscular de Duchenne/genética , Distrofia Muscular de Duchenne/terapia , Cromatografia Líquida , Espectrometria de Massas em Tandem , Músculo Esquelético/metabolismo , Terapia Genética/métodos
4.
Clin Chem ; 66(2): 282-301, 2020 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-32040572

RESUMO

Immunoaffinity-mass spectrometry (IA-MS) is an emerging analytical genre with several advantages for profiling and determination of protein biomarkers. Because IA-MS combines affinity capture, analogous to ligand binding assays (LBAs), with mass spectrometry (MS) detection, this platform is often described using the term hybrid methods. The purpose of this report is to provide an overview of the principles of IA-MS and to demonstrate, through application, the unique power and potential of this technology. By combining target immunoaffinity enrichment with the use of stable isotope-labeled internal standards and MS detection, IA-MS achieves high sensitivity while providing unparalleled specificity for the quantification of protein biomarkers in fluids and tissues. In recent years, significant uptake of IA-MS has occurred in the pharmaceutical industry, particularly in the early stages of clinical development, enabling biomarker measurement previously considered unattainable. By comparison, IA-MS adoption by CLIA laboratories has occurred more slowly. Current barriers to IA-MS use and opportunities for expanded adoption are discussed. The path forward involves identifying applications for which IA-MS is the best option compared with LBA or MS technologies alone. IA-MS will continue to benefit from advances in reagent generation, more sensitive and higher throughput MS technologies, and continued growth in use by the broader analytical community. Collectively, the pursuit of these opportunities will secure expanded long-term use of IA-MS for clinical applications.


Assuntos
Cromatografia Líquida/métodos , Imunoensaio/métodos , Espectrometria de Massas em Tandem/métodos , Bioensaio , Biomarcadores/análise , Humanos , Proteínas/análise , Sensibilidade e Especificidade
5.
Clin Chem ; 64(2): 279-288, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29054922

RESUMO

BACKGROUND: The half-life of target proteins is frequently an important parameter in mechanistic pharmacokinetic and pharmacodynamic (PK/PD) modeling of biotherapeutics. Clinical studies for accurate measurement of physiologically relevant protein turnover can reduce the uncertainty in PK/PD model-based predictions, for example, of the therapeutic dose and dosing regimen in first-in-human clinical trials. METHODS: We used a targeted mass spectrometry work flow based on serial immunoaffinity enrichment ofmultiple human serum proteins from a [5,5,5-2H3]-L-leucine tracer pulse-chase study in healthy volunteers. To confirm the reproducibility of turnover measurements from serial immunoaffinity enrichment, multiple aliquots from the same sample set were subjected to protein turnover analysis in varying order. Tracer incorporation was measured by multiple-reaction-monitoring mass spectrometry and target turnover was calculated using a four-compartment pharmacokinetic model. RESULTS: Five proteins of clinical or therapeutic relevance including soluble tumor necrosis factor receptor superfamily member 12A, tissue factor pathway inhibitor, soluble interleukin 1 receptor like 1, soluble mucosal addressin cell adhesion molecule 1, and muscle-specific creatine kinase were sequentially subjected to turnover analysis from the same human serum sample. Calculated half-lives ranged from 5-15 h; however, no tracer incorporation was observed for mucosal addressin cell adhesion molecule 1. CONCLUSIONS: The utility of clinical pulse-chase studies to investigate protein turnover can be extended by serial immunoaffinity enrichment of target proteins. Turnover analysis from serum and subsequently from remaining supernatants provided analytical sensitivity and reproducibility for multiple human target proteins in the same sample set, irrespective of the order of analysis.


Assuntos
Proteínas Sanguíneas/metabolismo , Cromatografia de Afinidade/métodos , Espectrometria de Massas em Tandem/métodos , Adulto , Artefatos , Proteínas Sanguíneas/química , Monitoramento de Medicamentos/métodos , Humanos , Leucina/sangue , Masculino , Reprodutibilidade dos Testes , Adulto Jovem
6.
Anal Chem ; 88(8): 4239-47, 2016 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-27012525

RESUMO

Neonatal Fc receptor (FcRn) is the homeostatic receptor responsible for the long half-life of endogenous IgG by protecting it from lysosomal degradation. Understanding systemic FcRn tissue expression is important to predict and design the half-life of therapeutic antibodies and Fc-coupled biotherapeutics. To this end, we measured human FcRn (hFcRn) tissue expression in Tg32, a human FcRn knock-in transgenic mouse model, for which a strong correlation of drug clearance to humans has been demonstrated. Building an hFcRn tissue expression profile in Tg32 was enabled by the development of a tissue preparation procedure composed of bead-based protein extraction and protein precipitation using acetone followed by pellet digestion with trypsin. Digests were then loaded onto an online peptide immuno-affinity flow configuration hyphenated with reversed phase nanoflow chromatography and coupled with high resolution mass spectrometry to quantify hFcRn derived peptides. The workflow allowed bypassing some of the challenges typically associated with membrane protein analysis. We demonstrated acceptable precision and bias for measuring hFcRn in tissue matrices, typically within 20% coefficient of variation and relative error. We also report hFcRn expression in several Tg32 tissues. We anticipate that establishing a quantitative approach for hFcRn in tissues will enable the systematic measurement of hFcRn concentrations to further increase the accuracy of physiologically based pharmacokinetic (PBPK) models for PK prediction of Fc-containing biotherapeutics. This is anticipated to improve the translation of pharmacokinetic data from preclinical model systems to humans.


Assuntos
Antígenos de Histocompatibilidade Classe I/análise , Imunoensaio , Peptídeos/imunologia , Receptores Fc/análise , Análise Serial de Tecidos , Animais , Anticorpos/imunologia , Cromatografia Líquida , Antígenos de Histocompatibilidade Classe I/imunologia , Humanos , Espectrometria de Massas , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Transgênicos , Receptores Fc/imunologia
7.
Clin Chem ; 62(1): 48-69, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26719571

RESUMO

BACKGROUND: For many years, basic and clinical researchers have taken advantage of the analytical sensitivity and specificity afforded by mass spectrometry in the measurement of proteins. Clinical laboratories are now beginning to deploy these work flows as well. For assays that use proteolysis to generate peptides for protein quantification and characterization, synthetic stable isotope-labeled internal standard peptides are of central importance. No general recommendations are currently available surrounding the use of peptides in protein mass spectrometric assays. CONTENT: The Clinical Proteomic Tumor Analysis Consortium of the National Cancer Institute has collaborated with clinical laboratorians, peptide manufacturers, metrologists, representatives of the pharmaceutical industry, and other professionals to develop a consensus set of recommendations for peptide procurement, characterization, storage, and handling, as well as approaches to the interpretation of the data generated by mass spectrometric protein assays. Additionally, the importance of carefully characterized reference materials-in particular, peptide standards for the improved concordance of amino acid analysis methods across the industry-is highlighted. The alignment of practices around the use of peptides and the transparency of sample preparation protocols should allow for the harmonization of peptide and protein quantification in research and clinical care.


Assuntos
Técnicas de Laboratório Clínico , Espectrometria de Massas , Peptídeos/análise , Proteômica , Manejo de Espécimes , Guias como Assunto , Humanos , Peptídeos/isolamento & purificação , Pesquisadores
8.
Mol Cell Proteomics ; 13(3): 907-17, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24443746

RESUMO

Adoption of targeted mass spectrometry (MS) approaches such as multiple reaction monitoring (MRM) to study biological and biomedical questions is well underway in the proteomics community. Successful application depends on the ability to generate reliable assays that uniquely and confidently identify target peptides in a sample. Unfortunately, there is a wide range of criteria being applied to say that an assay has been successfully developed. There is no consensus on what criteria are acceptable and little understanding of the impact of variable criteria on the quality of the results generated. Publications describing targeted MS assays for peptides frequently do not contain sufficient information for readers to establish confidence that the tests work as intended or to be able to apply the tests described in their own labs. Guidance must be developed so that targeted MS assays with established performance can be made widely distributed and applied by many labs worldwide. To begin to address the problems and their solutions, a workshop was held at the National Institutes of Health with representatives from the multiple communities developing and employing targeted MS assays. Participants discussed the analytical goals of their experiments and the experimental evidence needed to establish that the assays they develop work as intended and are achieving the required levels of performance. Using this "fit-for-purpose" approach, the group defined three tiers of assays distinguished by their performance and extent of analytical characterization. Computational and statistical tools useful for the analysis of targeted MS results were described. Participants also detailed the information that authors need to provide in their manuscripts to enable reviewers and readers to clearly understand what procedures were performed and to evaluate the reliability of the peptide or protein quantification measurements reported. This paper presents a summary of the meeting and recommendations.


Assuntos
Bioensaio/métodos , Biologia , Espectrometria de Massas/métodos , Medicina , Peptídeos/metabolismo , Animais , Guias como Assunto , Humanos , Marcação por Isótopo , Proteômica/normas , Padrões de Referência , Software
9.
Drug Metab Dispos ; 43(2): 227-33, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25349123

RESUMO

Advanced single-cell analysis technologies (e.g., mass cytometry) that help in multiplexing cellular measurements in limited-volume primary samples are critical in bridging discovery efforts to successful drug approval. Mass cytometry is the state-of-the-art technology in multiparametric single-cell analysis. Mass cytometers (also known as cytometry by time-of-flight or CyTOF) combine the cellular analysis principles of traditional fluorescence-based flow cytometry with the selectivity and quantitative power of inductively coupled plasma-mass spectrometry. Standard flow cytometry is limited in the number of parameters that can be measured owing to the overlap in signal when detecting fluorescently labeled antibodies. Mass cytometry uses antibodies tagged to stable isotopes of rare earth metals, which requires minimal signal compensation between the different metal tags. This unique feature enables researchers to seamlessly multiplex up to 40 independent measurements on single cells. In this overview we first present an overview of mass cytometry and compare it with traditional flow cytometry. We then discuss the emerging and potential applications of CyTOF technology in the pharmaceutical industry, including quantitative and qualitative deep profiling of immune cells and their applications in assessing drug immunogenicity, extensive mapping of signaling networks in single cells, cell surface receptor quantification and multiplexed internalization kinetics, multiplexing sample analysis by barcoding, and establishing cell ontologies on the basis of phenotype and/or function. We end with a discussion of the anticipated impact of this technology on drug development lifecycle with special emphasis on the utility of mass cytometry in deciphering a drug's pharmacokinetics and pharmacodynamics relationship.


Assuntos
Avaliação Pré-Clínica de Medicamentos/métodos , Análise de Célula Única , Animais , Biomarcadores/análise , Descoberta de Drogas/métodos , Descoberta de Drogas/tendências , Avaliação Pré-Clínica de Medicamentos/tendências , Citometria de Fluxo , Imunofluorescência , Humanos , Metais Terras Raras/análise , Farmacocinética , Análise de Célula Única/instrumentação , Espectrofotometria Atômica
12.
J Proteome Res ; 12(10): 4402-13, 2013 Oct 04.
Artigo em Inglês | MEDLINE | ID: mdl-23977844

RESUMO

Targeted quantitative proteomics using heavy isotope dilution techniques is increasingly being utilized to quantify proteins, including UGT enzymes, in biological matrices. Here we present a multiplexed method using nanoLC-MS/MS and multiple reaction monitoring (MRM) to quantify 14 UGT1As and UGT2Bs in liver matrices. Where feasible, we employ two or more proteotypic peptides per protein, with only four proteins quantified with only one proteotypic peptide. We apply the method to analysis of a library of 60 human liver microsome (HLM) and matching S9 samples. Ten of the UGT isoforms could be detected in liver, and the expression of each was consistent with mRNA expression reported in the literature. UGT2B17 was unusual in that ∼30% of liver microsomes had no or little (<0.5 pmol/mg protein) content, consistent with a known common polymorphism. Liver S9 UGT concentrations were approximately 10-15% those of microsomes. The method was robust, precise, and reproducible and provides novel UGT expression data in human liver that will benefit rational approaches to evaluate metabolism in drug development.


Assuntos
Glucuronosiltransferase/metabolismo , Fígado/enzimologia , Sequência de Aminoácidos , Cromatografia Líquida de Alta Pressão , Feminino , Glucuronosiltransferase/química , Humanos , Técnicas de Diluição do Indicador , Isoenzimas/química , Isoenzimas/metabolismo , Limite de Detecção , Masculino , Microssomos Hepáticos/enzimologia , Dados de Sequência Molecular , Fragmentos de Peptídeos/química , Proteômica , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem/métodos , Tripsina/química
13.
Anal Chem ; 85(3): 1719-26, 2013 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-23249404

RESUMO

Nerve growth factor (NGF) is a neurotrophin that is implicated in the modulation of pain perception. Tanezumab, a humanized monoclonal antibody (mAb) specific for NGF, is highly potent in sequestering NGF and has demonstrated efficacy for treatment of chronic pain in clinical trials. We describe a novel, sensitive immunoaffinity liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay for quantitative determination of human serum NGF levels at baseline and after tanezumab treatment. The assay combines magnetic bead-based NGF immunoaffinity enrichment using a non-neutralizing polyclonal antibody followed by digestion and quantitation of a NGF-derived tryptic peptide via high-flow peptide immunoaffinity enrichment and nanoflow LC-MS/MS. Following validation, the assay was employed to measure total NGF concentrations in samples from clinical studies. The assay had a <10% interassay relative error and <15% interassay coefficient of variation across a range from 7.03 to 450 pg/mL human NGF. Generally, human basal serum NGF concentrations were between 20 and 30 pg/mL which, upon treatment with tanezumab, elevated in a dose-dependent manner into the high pg/mL to low ng/mL range. This is the first report of clinical trial implementation of a MS-based assay that uses sequential protein and peptide immunoaffinity capture for protein target quantitation. The use of robotic sample preparation and a robust chromatography configuration enabled this technology to advance into the routine clinical analysis and now provides a bioanalytical platform for the development of similar assays for other protein targets.


Assuntos
Fator de Crescimento Neural/análise , Fragmentos de Peptídeos/análise , Espectrometria de Massas em Tandem/métodos , Sequência de Aminoácidos , Animais , Cromatografia Líquida/métodos , Cães , Humanos , Imunoensaio/métodos , Macaca fascicularis , Espectrometria de Massas/métodos , Dados de Sequência Molecular , Fator de Crescimento Neural/genética , Fragmentos de Peptídeos/genética , Ratos
14.
Anal Chem ; 85(11): 5522-9, 2013 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-23638938

RESUMO

A highly specific and sensitive immunoaffinity LC-MS/MS assay for quantification of human and cynomolgus monkey interleukin 21 (IL-21) was developed, qualified, and implemented. The workflow includes offline enrichment of IL-21 using an anti-IL-21 capture antibody, followed by isolation using magnetic beads, trypsin digestion, online enrichment of IL-21 derived tryptic peptides using antipeptide antibodies, and quantification using nanoflow LC-MS/MS. This assay was developed and qualified in human and cynomolgus monkey serum and tissues with a lower limit of quantitation of 0.78 pg/mL based on the intact cytokine. Both intra- and interbatch precision and accuracy, as well as stability and recovery, were found to be acceptable. IL-21 was not detected in serum from normal healthy volunteers or from autoimmune disease patients. However, IL-21 levels were quantified in cynomolgus monkey spleen and colon tissue and normal and inflammatory bowel disease (IBD) human colon tissue as well as hyperplasia human tonsils.


Assuntos
Cromatografia de Afinidade , Cromatografia Líquida/métodos , Separação Imunomagnética , Interleucinas/análise , Fragmentos de Peptídeos/análise , Espectrometria de Massas em Tandem/métodos , Animais , Anticorpos Monoclonais/imunologia , Anticorpos Monoclonais/metabolismo , Proteínas Sanguíneas/análise , Estudos de Casos e Controles , Colo/metabolismo , Humanos , Doenças Inflamatórias Intestinais/metabolismo , Interleucinas/imunologia , Macaca fascicularis , Tonsila Palatina/metabolismo , Proteínas Recombinantes/metabolismo , Sensibilidade e Especificidade , Baço/metabolismo , Tripsina/metabolismo
15.
Drug Metab Dispos ; 41(12): 2076-80, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24046331

RESUMO

Quantification methods employing stable isotope-labeled peptide standards and liquid chromatography-tandem mass spectrometry are increasingly being used to measure enzyme amounts in biologic samples. Isoform concentrations, combined with catalytic information, can be used in absorption, distribution, metabolism, and excretion studies to improve accuracy of in vitro/in vivo predictions. We quantified isoforms of uridine-diphosphate glucuronosyltransferase (UGT) 1A and 2B in 12 commercially available recombinant UGTs (recUGTs) (n = 49 samples) using nano-ultra-high-performance liquid chromatography-tandem mass spectrometry with selected reaction monitoring). Samples were trypsin-digested and analyzed using our previously published method. Two MRMs were collected per peptide and averaged. Where available, at least two peptides were measured per UGT isoform. The assay could detect UGTs in all recombinant preparations: recUGTs 1A1, 1A3, 1A4, 1A6, 1A7, 1A8, 1A9, 1A10, 2B4, 2B7, 2B15, and 2B17, with limit of detection below 1.0 pmol/mg protein for all isoforms. The assay had excellent linearity in the range observed (2-15.5 pmol/mg, after dilution). Examples of concentrations determined were 1465, 537, 538, 944, 865, 698, 604, 791, 382, 1149, 307, and 740 pmol/mg protein for the respective isoforms. There was a 6.9-fold difference between the maximum and minimum recUGT concentrations. The range of concentrations determined indicates that catalytic rates per mg total protein in vitro will not accurately reflect isoform inherent specific activity for a particular drug candidate. This is the first report of a targeted precise quantification of commercially available recUGTs. The assay has potential for use in comparing UGT amounts with catalytic activity determined using probe substrates, thus allowing representation of catalysis as per pmol of UGT isoform.


Assuntos
Glucuronosiltransferase/química , Isoformas de Proteínas/química , Proteínas Recombinantes/química , Catálise , Cromatografia Líquida de Alta Pressão/métodos , Humanos , Espectrometria de Massas em Tandem/métodos
16.
Sci Rep ; 13(1): 9180, 2023 06 06.
Artigo em Inglês | MEDLINE | ID: mdl-37280257

RESUMO

ß-Nerve growth factor (NGF) is a neurotrophin that plays a critical role in fetal development during gestation. ProNGF is the precursor form of NGF with a distinct biological profile. In order to investigate the role of NGF and proNGF in pregnant human females, a sensitive and selective immunoaffinity liquid chromatography-tandem mass spectrometry assay was developed and qualified to simultaneously measure the levels of total NGF (tNGF; sum of mature and proNGF) and proNGF using full and relative quantification strategies, respectively. The assay was used to determine serum tNGF and proNGF levels in the three gestational trimesters of pregnancy and in non-pregnant female controls. Mean tNGF ± SD were 44.6 ± 12.3, 42.6 ± 9.3, 65.4 ± 17.6 and 77.0 ± 17.8 pg/mL for non-pregnant, first, second, and third trimesters, respectively, demonstrating no significant increase in circulating tNGF between the control and the first trimester, and a moderate yet significant 1.7-fold increase through gestation. proNGF levels during the first trimester were unchanged compared to control. In contrast to tNGF, however, proNGF levels during gestation remained stable without significant changes. The development of this sensitive, novel immunoaffinity duplexed assay for both tNGF and proNGF is expected to enable further elucidation of the roles these neurotrophins play in human pregnancy as well as other models.


Assuntos
Fator de Crescimento Neural , Espectrometria de Massas em Tandem , Gravidez , Humanos , Feminino , Fator de Crescimento Neural/metabolismo , Cromatografia Líquida
17.
Mol Ther Methods Clin Dev ; 30: 30-47, 2023 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-37746247

RESUMO

Duchenne muscular dystrophy (DMD) is an X-linked disease caused by loss-of-function mutations in the dystrophin gene and is characterized by muscle wasting and early mortality. Adeno-associated virus-mediated gene therapy is being investigated as a treatment for DMD. In the nonclinical study documented here, we determined the effective dose of fordadistrogene movaparvovec, a clinical candidate adeno-associated virus serotype 9 vector carrying a human mini-dystrophin transgene, after single intravenous injection in a dystrophin-deficient (DMDmdx) rat model of DMD. Overall, we found that transduction efficiency, number of muscle fibers expressing the human mini-dystrophin polypeptide, improvement of the skeletal and cardiac muscle tissue architecture, correction of muscle strength and fatigability, and improvement of diastolic and systolic cardiac function were directly correlated with the amount of vector administered. The effective dose was then tested in older DMDmdx rats with a more dystrophic phenotype similar to the pathology observed in older patients with DMD. Except for a less complete rescue of muscle function in the oldest cohort, fordadistrogene movaparvovec was also found to be therapeutically effective in older DMDmdx rats, suggesting that this product may be appropriate for evaluation in patients with DMD at all stages of disease.

18.
Anal Chem ; 84(14): 5959-67, 2012 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-22816779

RESUMO

Liquid chromatography tandem mass spectrometry (LC-MS/MS) has been shown to be a viable tool for preclinical pharmacokinetic (PK) analysis of monoclonal antibody (mAb) therapeutics. This work describes free and total PK assays for the mAb PF-00547,659 in serum of ulcerative colitis patients in a First-In-Human study [Vermeire, S. et al. Gut2011, 60 (8), 1068-1075]. The assay to measure free PF-00547,659 used immuno-enrichment with a biotinylated anti-idiotypic antibody and streptavidin magnetic beads. The total assay used enrichment by protein G magnetic beads. Following elution of PF-00547,659 from the beads, addition of an extended sequence stable isotope labeled peptide and trypsin digestion, a proteotypic peptide derived from the CDR region of the light chain of PF-00547,659 was quantified by LC-MS/MS. The free assay had a calibration range from 7.03 ng/mL to 450 ng/mL. The assay was precise and accurate with interbatch imprecision <16.5%, and interbatch inaccuracy <13.7% at all concentrations investigated during assay qualification. Results from LC-MS/MS methodologies are compared with historical immunoassay data originally acquired during the course of the clinical study. PK parameter estimates were highly correlated between the two analytical approaches. This work provides precedence that immunoaffinity LC-MS/MS can effectively be used to measure the serum concentrations of mAb therapeutics in clinical studies.


Assuntos
Anticorpos Monoclonais/farmacocinética , Anticorpos Monoclonais/uso terapêutico , Cromatografia Líquida/métodos , Mucoproteínas/imunologia , Espectrometria de Massas em Tandem/métodos , Anticorpos Monoclonais/imunologia , Humanos , Imunoensaio
19.
Methods Mol Biol ; 2466: 111-119, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35585314

RESUMO

Immunoaffinity mass spectrometry (IA-MS) is a powerful analytical technique for the determination of protein biomarkers with high sensitivity and unparalleled specificity. Typically, the protein antigen of interest is captured from biofluids and tissue lysates using an antibody prior to mass spectrometric analysis. Here we describe the specific steps of the protein immunoaffinity component of the IA-MS workflow that is applicable to most protein antigens.


Assuntos
Anticorpos , Proteínas , Anticorpos/química , Antígenos , Biomarcadores/análise , Espectrometria de Massas/métodos , Proteínas/análise
20.
AAPS J ; 25(1): 12, 2022 12 20.
Artigo em Inglês | MEDLINE | ID: mdl-36539515

RESUMO

Duchenne muscular dystrophy (DMD) is a degenerative muscular disease affecting roughly one in 5000 males at birth. The disease is often caused by inherited X-linked recessive pathogenic variants in the dystrophin gene, but may also arise from de novo mutations. Disease-causing variants include nonsense, out of frame deletions or duplications that result in loss of dystrophin protein expression. There is currently no cure for DMD and the few treatment options available aim at slowing muscle degradation. New advances in gene therapy and understanding of dystrophin (DYS) expression in other muscular dystrophies have opened new opportunities for treatment. Therefore, reliable methods are needed to monitor dystrophin expression and assess the efficacy of new therapies for muscular dystrophies such as DMD and Becker muscular dystrophy (BMD). Here, we describe the validation of a novel Western blot (WB) method for the quantitation of mini-dystrophin protein in human skeletal muscle tissues that is easy to adopt in most laboratory settings. This WB method was assessed through precision, accuracy, selectivity, dilution linearity, stability, and repeatability. Based on mini-DYS standard performance, the assay has a dynamic range of 0.5-15 ng protein (per 5 µg total protein per lane), precision of 3.3 to 25.5%, and accuracy of - 7.5 to 3.3%. Our stability assessment showed that the protein is stable after 4 F/T cycles, up to 2 h at RT and after 7 months at - 70°C. Furthermore, our WB method was compared to the results from our recently published LC-MS method. Workflow for our quantitative WB method to determine mini-dystrophin levels in muscle tissues (created in Biorender.com). Step 1 involves protein extraction from skeletal muscle tissue lysates from control, DMD, or BMD biospecimen. Step 2 measures total protein concentrations. Step 3 involves running gel electrophoresis with wild-type dystrophin (wt-DYS) from muscle tissue extracts alongside mini-dystrophin STD curve and mini-DYS and protein normalization with housekeeping GAPDH.


Assuntos
Distrofina , Distrofia Muscular de Duchenne , Masculino , Recém-Nascido , Humanos , Distrofina/genética , Distrofina/análise , Distrofina/metabolismo , Distrofia Muscular de Duchenne/genética , Distrofia Muscular de Duchenne/metabolismo , Distrofia Muscular de Duchenne/patologia , Músculo Esquelético/química , Músculo Esquelético/metabolismo , Músculo Esquelético/patologia , Biópsia , Western Blotting
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA